TRIPPLITE-PRODUCTS

File: TRIPPLITE-PRODUCTS.mib (411738 bytes)

Imported modules

SNMPv2-TC SNMPv2-MIB SNMPv2-CONF
SNMPv2-SMI TRIPPLITE

Imported symbols

DisplayString TruthValue TimeStamp
RowStatus sysUpTime OBJECT-GROUP
NOTIFICATION-GROUP MODULE-IDENTITY OBJECT-IDENTITY
OBJECT-TYPE NOTIFICATION-TYPE Gauge32
Integer32 Unsigned32 enterprises
IpAddress TimeTicks tripplite

Defined Types

TlpDeviceEntry  
SEQUENCE    
  tlpDeviceIndex Unsigned32
  tlpDeviceRowStatus RowStatus
  tlpDeviceType OBJECT IDENTIFIER
  tlpDeviceManufacturer DisplayString
  tlpDeviceModel DisplayString
  tlpDeviceName DisplayString
  tlpDeviceID INTEGER
  tlpDeviceLocation DisplayString
  tlpDeviceRegion DisplayString
  tlpDeviceStatus INTEGER

TlpDeviceIdentEntry  
SEQUENCE    
  tlpDeviceIdentProtocol DisplayString
  tlpDeviceIdentCommPortType INTEGER
  tlpDeviceIdentCommPortName DisplayString
  tlpDeviceIdentFirmwareVersion DisplayString
  tlpDeviceIdentSerialNum DisplayString
  tlpDeviceIdentDateInstalled DisplayString
  tlpDeviceIdentHardwareVersion DisplayString
  tlpDeviceIdentCurrentUptime DisplayString
  tlpDeviceIdentTotalUptime DisplayString
  tlpDeviceIdentFirmwareVersion2 DisplayString
  tlpDeviceIdentFirmwareVersion3 DisplayString
  tlpDeviceIdentNvrID DisplayString

TlpUpsIdentEntry  
SEQUENCE    
  tlpUpsIdentNumInputs Unsigned32
  tlpUpsIdentNumOutputs Unsigned32
  tlpUpsIdentNumBypass Unsigned32
  tlpUpsIdentNumPhases Unsigned32
  tlpUpsIdentNumOutlets Unsigned32
  tlpUpsIdentNumOutletGroups Unsigned32
  tlpUpsIdentNumBatteryPacks Unsigned32
  tlpUpsIdentNumFans Unsigned32

TlpUpsSupportsEntry  
SEQUENCE    
  tlpUpsSupportsEnergywise TruthValue
  tlpUpsSupportsRampShed TruthValue
  tlpUpsSupportsOutletGroup TruthValue
  tlpUpsSupportsOutletCurrentPower TruthValue
  tlpUpsSupportsOutletVoltage TruthValue

TlpUpsDeviceEntry  
SEQUENCE    
  tlpUpsDeviceMainLoadState INTEGER
  tlpUpsDeviceMainLoadControllable TruthValue
  tlpUpsDeviceMainLoadCommand INTEGER
  tlpUpsDevicePowerOnDelay Integer32
  tlpUpsDeviceTestDate DisplayString
  tlpUpsDeviceTestResultsStatus INTEGER
  tlpUpsDeviceTemperatureC Integer32
  tlpUpsDeviceTemperatureF Integer32
  tlpUpsDeviceLastACFailureReason INTEGER
  tlpUpsDeviceLastShutdownReason INTEGER
  tlpUpsDeviceOutputCurrentPrecision INTEGER

TlpUpsBatterySummaryEntry  
SEQUENCE    
  tlpUpsBatteryStatus INTEGER
  tlpUpsSecondsOnBattery Unsigned32
  tlpUpsEstimatedMinutesRemaining Unsigned32
  tlpUpsEstimatedChargeRemaining INTEGER
  tlpUpsBatteryRunTimeRemaining TimeTicks

TlpUpsBatteryDetailEntry  
SEQUENCE    
  tlpUpsBatteryDetailVoltage Unsigned32
  tlpUpsBatteryDetailCurrent Integer32
  tlpUpsBatteryDetailCapacity INTEGER
  tlpUpsBatteryDetailCharge INTEGER
  tlpUpsBatteryDetailChargerStatus INTEGER

TlpUpsBatteryIdentEntry  
SEQUENCE    
  tlpUpsBatteryPackIdentIndex Unsigned32
  tlpUpsBatteryPackIdentManufacturer DisplayString
  tlpUpsBatteryPackIdentModel DisplayString
  tlpUpsBatteryPackIdentSerialNum DisplayString
  tlpUpsBatteryPackIdentFirmware DisplayString
  tlpUpsBatteryPackIdentSKU DisplayString

TlpUpsBatteryConfigEntry  
SEQUENCE    
  tlpUpsBatteryPackConfigChemistry INTEGER
  tlpUpsBatteryPackConfigStyle INTEGER
  tlpUpsBatteryPackConfigLocation INTEGER
  tlpUpsBatteryPackConfigStrings Unsigned32
  tlpUpsBatteryPackConfigBatteriesPerString Unsigned32
  tlpUpsBatteryPackConfigCellsPerBattery INTEGER
  tlpUpsBatteryPackConfigNumBatteries Unsigned32
  tlpUpsBatteryPackConfigCapacityUnits INTEGER
  tlpUpsBatteryPackConfigDesignCapacity Unsigned32
  tlpUpsBatteryPackConfigCellCapacity Unsigned32
  tlpUpsBatteryPackConfigMinCellVoltage Unsigned32
  tlpUpsBatteryPackConfigMaxCellVoltage Unsigned32

TlpUpsBatteryPackDetailEntry  
SEQUENCE    
  tlpUpsBatteryPackDetailCondition INTEGER
  tlpUpsBatteryPackDetailTemperatureC Unsigned32
  tlpUpsBatteryPackDetailTemperatureF Unsigned32
  tlpUpsBatteryPackDetailAge Unsigned32
  tlpUpsBatteryPackDetailLastReplaceDate DisplayString
  tlpUpsBatteryPackDetailNextReplaceDate DisplayString
  tlpUpsBatteryPackDetailCycleCount Unsigned32

TlpUpsInputEntry  
SEQUENCE    
  tlpUpsInputLineBads INTEGER
  tlpUpsInputNominalVoltage Unsigned32
  tlpUpsInputNominalFrequency Unsigned32
  tlpUpsInputLowTransferVoltage Unsigned32
  tlpUpsInputLowTransferVoltageLowerBound Unsigned32
  tlpUpsInputLowTransferVoltageUpperBound Unsigned32
  tlpUpsInputHighTransferVoltage Unsigned32
  tlpUpsInputHighTransferVoltageLowerBound Unsigned32
  tlpUpsInputHighTransferVoltageUpperBound Unsigned32
  tlpUpsInputWattHours Unsigned32

TlpUpsInputPhaseEntry  
SEQUENCE    
  tlpUpsInputPhaseIndex Unsigned32
  tlpUpsInputPhaseFrequency Unsigned32
  tlpUpsInputPhaseVoltage Unsigned32
  tlpUpsInputPhaseVoltageMin Unsigned32
  tlpUpsInputPhaseVoltageMax Unsigned32
  tlpUpsInputPhaseCurrent Unsigned32
  tlpUpsInputPhasePower Unsigned32

TlpUpsOutputEntry  
SEQUENCE    
  tlpUpsOutputSource INTEGER
  tlpUpsOutputNominalVoltage Unsigned32
  tlpUpsOutputFrequency Unsigned32
  tlpUpsOutputVARating Unsigned32

TlpUpsOutputLineEntry  
SEQUENCE    
  tlpUpsOutputLineIndex Unsigned32
  tlpUpsOutputLineVoltage Unsigned32
  tlpUpsOutputLineCurrent Unsigned32
  tlpUpsOutputLinePower Unsigned32
  tlpUpsOutputLinePercentLoad INTEGER
  tlpUpsOutputLineFrequency Unsigned32

TlpUpsBypassEntry  
SEQUENCE    
  tlpUpsBypassFrequency Unsigned32

TlpUpsBypassLineEntry  
SEQUENCE    
  tlpUpsBypassLineIndex Unsigned32
  tlpUpsBypassLineVoltage Unsigned32
  tlpUpsBypassLineCurrent Unsigned32
  tlpUpsBypassLinePower Unsigned32

TlpUpsOutletEntry  
SEQUENCE    
  tlpUpsOutletIndex Unsigned32
  tlpUpsOutletName DisplayString
  tlpUpsOutletDescription DisplayString
  tlpUpsOutletState INTEGER
  tlpUpsOutletControllable TruthValue
  tlpUpsOutletCommand INTEGER
  tlpUpsOutletVoltage Unsigned32
  tlpUpsOutletCurrent Unsigned32
  tlpUpsOutletPower Unsigned32
  tlpUpsOutletRampAction INTEGER
  tlpUpsOutletRampDelay Integer32
  tlpUpsOutletShedAction INTEGER
  tlpUpsOutletShedDelay Integer32
  tlpUpsOutletGroup Integer32

TlpUpsOutletGroupEntry  
SEQUENCE    
  tlpUpsOutletGroupIndex Unsigned32
  tlpUpsOutletGroupRowStatus RowStatus
  tlpUpsOutletGroupName DisplayString
  tlpUpsOutletGroupDescription DisplayString
  tlpUpsOutletGroupState INTEGER
  tlpUpsOutletGroupCommand INTEGER

TlpUpsWatchdogEntry  
SEQUENCE    
  tlpUpsWatchdogSupported TruthValue
  tlpUpsWatchdogSecsBeforeReboot Unsigned32

TlpUpsFanEntry  
SEQUENCE    
  tlpUpsFanIndex Unsigned32
  tlpUpsFanSpeed Unsigned32

TlpUpsControlEntry  
SEQUENCE    
  tlpUpsControlSelfTest TruthValue
  tlpUpsControlRamp TruthValue
  tlpUpsControlShed TruthValue
  tlpUpsControlUpsOn TruthValue
  tlpUpsControlUpsOff TruthValue
  tlpUpsControlUpsReboot TruthValue
  tlpUpsControlBypass INTEGER
  tlpUpsControlResetWattHours TruthValue

TlpUpsConfigEntry  
SEQUENCE    
  tlpUpsConfigInputVoltage Unsigned32
  tlpUpsConfigInputFrequency Unsigned32
  tlpUpsConfigOutputVoltage Unsigned32
  tlpUpsConfigOutputFrequency Unsigned32
  tlpUpsConfigAudibleStatus INTEGER
  tlpUpsConfigAutoBatteryTest INTEGER
  tlpUpsConfigAutoRestartAfterShutdown INTEGER
  tlpUpsConfigAutoRampOnTransition INTEGER
  tlpUpsConfigAutoShedOnTransition INTEGER
  tlpUpsConfigBypassLowerLimitPercent INTEGER
  tlpUpsConfigBypassUpperLimitPercent INTEGER
  tlpUpsConfigBypassLowerLimitVoltage Unsigned32
  tlpUpsConfigBypassUpperLimitVoltage Unsigned32
  tlpUpsConfigColdStart INTEGER
  tlpUpsConfigEconomicMode INTEGER
  tlpUpsConfigFaultAction INTEGER
  tlpUpsConfigOffMode INTEGER
  tlpUpsConfigLineSensitivity INTEGER

TlpUpsConfigAutoRestartEntry  
SEQUENCE    
  tlpUpsConfigAutoRestartInverterShutdown INTEGER
  tlpUpsConfigAutoRestartDelayedWakeup INTEGER
  tlpUpsConfigAutoRestartLowVoltageCutoff INTEGER
  tlpUpsConfigAutoRestartOverLoad INTEGER
  tlpUpsConfigAutoRestartOverTemperature INTEGER

TlpUpsConfigThresholdEntry  
SEQUENCE    
  tlpUpsConfigBatteryAgeThreshold Unsigned32
  tlpUpsConfigLowBatteryThreshold INTEGER
  tlpUpsConfigLowBatteryTime Unsigned32
  tlpUpsConfigOverLoadThreshold INTEGER

TlpPduIdentEntry  
SEQUENCE    
  tlpPduIdentNumInputs Unsigned32
  tlpPduIdentNumOutputs Unsigned32
  tlpPduIdentNumPhases Unsigned32
  tlpPduIdentNumOutlets Unsigned32
  tlpPduIdentNumOutletGroups Unsigned32
  tlpPduIdentNumCircuits Unsigned32
  tlpPduIdentNumBreakers Unsigned32
  tlpPduIdentNumHeatsinks Unsigned32

TlpPduSupportsEntry  
SEQUENCE    
  tlpPduSupportsEnergywise TruthValue
  tlpPduSupportsRampShed TruthValue
  tlpPduSupportsOutletGroup TruthValue
  tlpPduSupportsOutletCurrentPower TruthValue
  tlpPduSupportsOutletVoltage TruthValue

TlpPduDisplayEntry  
SEQUENCE    
  tlpPduDisplayScheme INTEGER
  tlpPduDisplayOrientation INTEGER
  tlpPduDisplayAutoScroll INTEGER
  tlpPduDisplayIntensity INTEGER
  tlpPduDisplayUnits INTEGER

TlpPduDeviceEntry  
SEQUENCE    
  tlpPduDeviceMainLoadState INTEGER
  tlpPduDeviceMainLoadControllable TruthValue
  tlpPduDeviceMainLoadCommand INTEGER
  tlpPduDevicePowerOnDelay Integer32
  tlpPduDeviceTotalInputPowerRating Integer32
  tlpPduDeviceTemperatureC Integer32
  tlpPduDeviceTemperatureF Integer32
  tlpPduDevicePhaseImbalance INTEGER
  tlpPduDeviceOutputPowerTotal Unsigned32
  tlpPduDeviceAggregatePowerFactor Unsigned32
  tlpPduDeviceOutputCurrentPrecision INTEGER

TlpPduInputEntry  
SEQUENCE    
  tlpPduInputNominalVoltage Unsigned32
  tlpPduInputNominalVoltagePhaseToPhase Unsigned32
  tlpPduInputNominalVoltagePhaseToNeutral Unsigned32
  tlpPduInputLowTransferVoltage Unsigned32
  tlpPduInputLowTransferVoltageLowerBound Unsigned32
  tlpPduInputLowTransferVoltageUpperBound Unsigned32
  tlpPduInputHighTransferVoltage Unsigned32
  tlpPduInputHighTransferVoltageLowerBound Unsigned32
  tlpPduInputHighTransferVoltageUpperBound Unsigned32
  tlpPduInputCurrentLimit Unsigned32

TlpPduInputPhaseEntry  
SEQUENCE    
  tlpPduInputPhaseIndex Unsigned32
  tlpPduInputPhasePhaseType INTEGER
  tlpPduInputPhaseFrequency Unsigned32
  tlpPduInputPhaseVoltage Unsigned32
  tlpPduInputPhaseVoltageMin Unsigned32
  tlpPduInputPhaseVoltageMax Unsigned32
  tlpPduInputPhaseCurrent Unsigned32

TlpPduOutputEntry  
SEQUENCE    
  tlpPduOutputIndex Unsigned32
  tlpPduOutputPhase INTEGER
  tlpPduOutputPhaseType INTEGER
  tlpPduOutputVoltage Unsigned32
  tlpPduOutputCurrent Unsigned32
  tlpPduOutputCurrentMin Unsigned32
  tlpPduOutputCurrentMax Unsigned32
  tlpPduOutputActivePower Unsigned32
  tlpPduOutputPowerFactor Unsigned32
  tlpPduOutputSource INTEGER
  tlpPduOutputFrequency Unsigned32
  tlpPduOutputCalculatedPowerKVA Unsigned32
  tlpPduOutputCalculatedPowerKW Unsigned32
  tlpPduOutputCalculated24hrEnergy Unsigned32

TlpPduOutletEntry  
SEQUENCE    
  tlpPduOutletIndex Unsigned32
  tlpPduOutletName DisplayString
  tlpPduOutletDescription DisplayString
  tlpPduOutletState INTEGER
  tlpPduOutletControllable TruthValue
  tlpPduOutletCommand INTEGER
  tlpPduOutletVoltage Unsigned32
  tlpPduOutletCurrent Unsigned32
  tlpPduOutletPower Unsigned32
  tlpPduOutletRampAction INTEGER
  tlpPduOutletRampDelay Integer32
  tlpPduOutletShedAction INTEGER
  tlpPduOutletShedDelay Integer32
  tlpPduOutletGroup Integer32
  tlpPduOutletBank Integer32
  tlpPduOutletCircuit Integer32
  tlpPduOutletPhase INTEGER

TlpPduOutletGroupEntry  
SEQUENCE    
  tlpPduOutletGroupIndex Unsigned32
  tlpPduOutletGroupRowStatus RowStatus
  tlpPduOutletGroupName DisplayString
  tlpPduOutletGroupDescription DisplayString
  tlpPduOutletGroupState INTEGER
  tlpPduOutletGroupCommand INTEGER

TlpPduCircuitEntry  
SEQUENCE    
  tlpPduCircuitIndex Unsigned32
  tlpPduCircuitPhase INTEGER
  tlpPduCircuitInputVoltage Integer32
  tlpPduCircuitTotalCurrent Integer32
  tlpPduCircuitCurrentLimit Integer32
  tlpPduCircuitCurrentMin Integer32
  tlpPduCircuitCurrentMax Integer32
  tlpPduCircuitTotalPower Integer32
  tlpPduCircuitPowerFactor INTEGER
  tlpPduCircuitUtilization Unsigned32

TlpPduBreakerEntry  
SEQUENCE    
  tlpPduBreakerIndex Unsigned32
  tlpPduBreakerStatus INTEGER

TlpPduHeatsinkEntry  
SEQUENCE    
  tlpPduHeatsinkIndex Unsigned32
  tlpPduHeatsinkStatus INTEGER
  tlpPduHeatsinkTemperatureC Integer32
  tlpPduHeatsinkTemperatureF Integer32

TlpPduControlEntry  
SEQUENCE    
  tlpPduControlRamp TruthValue
  tlpPduControlShed TruthValue
  tlpPduControlPduOn TruthValue
  tlpPduControlPduOff TruthValue
  tlpPduControlPduReboot TruthValue

TlpPduConfigEntry  
SEQUENCE    
  tlpPduConfigInputVoltage Unsigned32

TlpPduConfigPhaseThresholdEntry  
SEQUENCE    
  tlpPduPhaseIndex Unsigned32
  tlpPduConfigOutputCurrentThresholdTolerance Unsigned32
  tlpPduConfigOutputCurrentHighThreshold Unsigned32
  tlpPduConfigOutputCurrentLowThreshold Unsigned32

TlpEnvIdentEntry  
SEQUENCE    
  tlpEnvIdentTempSupported TruthValue
  tlpEnvIdentHumiditySupported TruthValue
  tlpEnvNumInputContacts Unsigned32
  tlpEnvNumOutputContacts Unsigned32

TlpEnvTemperatureEntry  
SEQUENCE    
  tlpEnvTemperatureC Integer32
  tlpEnvTemperatureF Integer32
  tlpEnvTemperatureInAlarm TruthValue

TlpEnvHumidityEntry  
SEQUENCE    
  tlpEnvHumidityHumidity INTEGER
  tlpEnvHumidityInAlarm TruthValue

TlpEnvInputContactEntry  
SEQUENCE    
  tlpEnvInputContactIndex Unsigned32
  tlpEnvInputContactName DisplayString
  tlpEnvInputContactNormalState INTEGER
  tlpEnvInputContactCurrentState INTEGER
  tlpEnvInputContactInAlarm TruthValue

TlpEnvOutputContactEntry  
SEQUENCE    
  tlpEnvOutputContactIndex Unsigned32
  tlpEnvOutputContactName DisplayString
  tlpEnvOutputContactNormalState INTEGER
  tlpEnvOutputContactCurrentState INTEGER
  tlpEnvOutputContactInAlarm TruthValue

TlpEnvConfigEntry  
SEQUENCE    
  tlpEnvTemperatureLowLimit Integer32
  tlpEnvTemperatureHighLimit Integer32
  tlpEnvHumidityLowLimit INTEGER
  tlpEnvHumidityHighLimit INTEGER

TlpAtsIdentEntry  
SEQUENCE    
  tlpAtsIdentNumInputs Unsigned32
  tlpAtsIdentNumOutputs Unsigned32
  tlpAtsIdentNumPhases Unsigned32
  tlpAtsIdentNumOutlets Unsigned32
  tlpAtsIdentNumOutletGroups Unsigned32
  tlpAtsIdentNumCircuits Unsigned32
  tlpAtsIdentNumBreakers Unsigned32
  tlpAtsIdentNumHeatsinks Unsigned32

TlpAtsSupportsEntry  
SEQUENCE    
  tlpAtsSupportsEnergywise TruthValue
  tlpAtsSupportsRampShed TruthValue
  tlpAtsSupportsOutletGroup TruthValue
  tlpAtsSupportsOutletCurrentPower TruthValue
  tlpAtsSupportsOutletVoltage TruthValue

TlpAtsDisplayEntry  
SEQUENCE    
  tlpAtsDisplayScheme INTEGER
  tlpAtsDisplayOrientation INTEGER
  tlpAtsDisplayAutoScroll INTEGER
  tlpAtsDisplayIntensity INTEGER
  tlpAtsDisplayUnits INTEGER

TlpAtsDeviceEntry  
SEQUENCE    
  tlpAtsDeviceMainLoadState INTEGER
  tlpAtsDeviceMainLoadControllable TruthValue
  tlpAtsDeviceMainLoadCommand INTEGER
  tlpAtsDevicePowerOnDelay Integer32
  tlpAtsDeviceTotalInputPowerRating Integer32
  tlpAtsDeviceTemperatureC Integer32
  tlpAtsDeviceTemperatureF Integer32
  tlpAtsDevicePhaseImbalance INTEGER
  tlpAtsDeviceOutputPowerTotal Unsigned32
  tlpAtsDeviceAggregatePowerFactor Unsigned32
  tlpAtsDeviceOutputCurrentPrecision INTEGER
  tlpAtsDeviceGeneralFault TruthValue

TlpAtsInputEntry  
SEQUENCE    
  tlpAtsInputNominalVoltage Unsigned32
  tlpAtsInputNominalVoltagePhaseToPhase Unsigned32
  tlpAtsInputNominalVoltagePhaseToNeutral Unsigned32
  tlpAtsInputBadTransferVoltage Unsigned32
  tlpAtsInputBadTransferVoltageLowerBound Unsigned32
  tlpAtsInputBadTransferVoltageUpperBound Unsigned32
  tlpAtsInputHighTransferVoltage Unsigned32
  tlpAtsInputHighTransferVoltageLowerBound Unsigned32
  tlpAtsInputHighTransferVoltageUpperBound Unsigned32
  tlpAtsInputFairVoltageThreshold Unsigned32
  tlpAtsInputBadVoltageThreshold Unsigned32
  tlpAtsInputSourceAvailability INTEGER
  tlpAtsInputSourceInUse INTEGER
  tlpAtsInputSourceTransitionCount Unsigned32
  tlpAtsInputCurrentLimit Unsigned32

TlpAtsInputPhaseEntry  
SEQUENCE    
  tlpAtsInputLineIndex Unsigned32
  tlpAtsInputPhaseIndex Unsigned32
  tlpAtsInputPhaseType INTEGER
  tlpAtsInputPhaseFrequency Unsigned32
  tlpAtsInputPhaseVoltage Unsigned32
  tlpAtsInputPhaseVoltageMin Unsigned32
  tlpAtsInputPhaseVoltageMax Unsigned32
  tlpAtsInputPhaseCurrent Unsigned32

TlpAtsOutputEntry  
SEQUENCE    
  tlpAtsOutputIndex Unsigned32
  tlpAtsOutputPhase INTEGER
  tlpAtsOutputPhaseType INTEGER
  tlpAtsOutputVoltage Unsigned32
  tlpAtsOutputCurrent Unsigned32
  tlpAtsOutputCurrentMin Unsigned32
  tlpAtsOutputCurrentMax Unsigned32
  tlpAtsOutputActivePower Unsigned32
  tlpAtsOutputPowerFactor Unsigned32
  tlpAtsOutputSource INTEGER
  tlpAtsOutputFrequency Unsigned32
  tlpAtsOutputCalculatedPowerKVA Unsigned32
  tlpAtsOutputCalculatedPowerKW Unsigned32
  tlpAtsOutputCalculated24hrEnergy Unsigned32

TlpAtsOutletEntry  
SEQUENCE    
  tlpAtsOutletIndex Unsigned32
  tlpAtsOutletName DisplayString
  tlpAtsOutletDescription DisplayString
  tlpAtsOutletState INTEGER
  tlpAtsOutletControllable TruthValue
  tlpAtsOutletCommand INTEGER
  tlpAtsOutletVoltage Unsigned32
  tlpAtsOutletCurrent Unsigned32
  tlpAtsOutletPower Unsigned32
  tlpAtsOutletRampAction INTEGER
  tlpAtsOutletRampDelay Integer32
  tlpAtsOutletShedAction INTEGER
  tlpAtsOutletShedDelay Integer32
  tlpAtsOutletGroup Integer32
  tlpAtsOutletBank Integer32
  tlpAtsOutletCircuit Integer32
  tlpAtsOutletPhase INTEGER

TlpAtsOutletGroupEntry  
SEQUENCE    
  tlpAtsOutletGroupIndex Unsigned32
  tlpAtsOutletGroupRowStatus RowStatus
  tlpAtsOutletGroupName DisplayString
  tlpAtsOutletGroupDescription DisplayString
  tlpAtsOutletGroupState INTEGER
  tlpAtsOutletGroupCommand INTEGER

TlpAtsCircuitEntry  
SEQUENCE    
  tlpAtsCircuitIndex Unsigned32
  tlpAtsCircuitPhase INTEGER
  tlpAtsCircuitInputVoltage Integer32
  tlpAtsCircuitTotalCurrent Integer32
  tlpAtsCircuitCurrentLimit Integer32
  tlpAtsCircuitCurrentMin Integer32
  tlpAtsCircuitCurrentMax Integer32
  tlpAtsCircuitTotalPower Integer32
  tlpAtsCircuitPowerFactor INTEGER
  tlpAtsCircuitUtilization Unsigned32

TlpAtsBreakerEntry  
SEQUENCE    
  tlpAtsBreakerIndex Unsigned32
  tlpAtsBreakerStatus INTEGER

TlpAtsHeatsinkEntry  
SEQUENCE    
  tlpAtsHeatsinkIndex Unsigned32
  tlpAtsHeatsinkStatus INTEGER
  tlpAtsHeatsinkTemperatureC Integer32
  tlpAtsHeatsinkTemperatureF Integer32

TlpAtsControlEntry  
SEQUENCE    
  tlpAtsControlRamp TruthValue
  tlpAtsControlShed TruthValue
  tlpAtsControlAtsOn TruthValue
  tlpAtsControlAtsOff TruthValue
  tlpAtsControlAtsReboot TruthValue
  tlpAtsControlResetGeneralFault TruthValue

TlpAtsConfigEntry  
SEQUENCE    
  tlpAtsConfigInputVoltage Unsigned32
  tlpAtsConfigSourceSelect INTEGER
  tlpAtsConfigSource1ReturnTime Unsigned32
  tlpAtsConfigSource2ReturnTime Unsigned32
  tlpAtsConfigAutoRampOnTransition INTEGER
  tlpAtsConfigAutoShedOnTransition INTEGER

TlpAtsConfigVoltageRangeOldEntry  
SEQUENCE    
  tlpAtsConfigHighVoltageTransferOld Unsigned32
  tlpAtsConfigHighVoltageResetOld Unsigned32
  tlpAtsConfigSource1TransferResetOld Unsigned32
  tlpAtsConfigSource1BrownoutSetOld Unsigned32
  tlpAtsConfigSource1TransferSetOld Unsigned32
  tlpAtsConfigSource2TransferResetOld Unsigned32
  tlpAtsConfigSource2BrownoutSetOld Unsigned32
  tlpAtsConfigSource2TransferSetOld Unsigned32
  tlpAtsConfigLowVoltageResetOld Unsigned32
  tlpAtsConfigLowVoltageTransferOld Unsigned32

TlpAtsConfigVoltageRangeLimitsEntry  
SEQUENCE    
  tlpAtsConfigSourceBrownoutSetMinimum Unsigned32
  tlpAtsConfigSourceBrownoutSetMaximum Unsigned32
  tlpAtsConfigSourceTransferSetMinimum Unsigned32
  tlpAtsConfigSourceTransferSetMaximum Unsigned32

TlpAtsConfigThresholdEntry  
SEQUENCE    
  tlpAtsConfigOutputCurrentThreshold Unsigned32
  tlpAtsConfigOverTemperatureThreshold Unsigned32
  tlpAtsConfigOverVoltageThreshold Unsigned32
  tlpAtsConfigOverLoadThreshold Unsigned32

TlpAtsConfigVoltageRangeEntry  
SEQUENCE    
  tlpAtsConfigHighVoltageTransfer Unsigned32
  tlpAtsConfigHighVoltageReset Unsigned32
  tlpAtsConfigTransferReset Unsigned32
  tlpAtsConfigBrownoutSet Unsigned32
  tlpAtsConfigTransferSet Unsigned32
  tlpAtsConfigLowVoltageReset Unsigned32
  tlpAtsConfigLowVoltageTransfer Unsigned32

TlpAtsConfigPhaseThresholdEntry  
SEQUENCE    
  tlpAtsPhaseIndex Unsigned32
  tlpAtsConfigOutputCurrentThresholdTolerance Unsigned32
  tlpAtsConfigOutputCurrentHighThreshold Unsigned32
  tlpAtsConfigOutputCurrentLowThreshold Unsigned32

TlpCoolingCurrentEntry  
SEQUENCE    
  tlpCoolingUnitCurrent Unsigned32
  tlpCoolingCompressorCurrent Unsigned32
  tlpCoolingEvaporatorFanCurrent Unsigned32
  tlpCoolingCondenserFanCurrent Unsigned32

TlpCoolingTemperatureFahrenheitEntry  
SEQUENCE    
  tlpCoolingAmbientDegF Integer32
  tlpCoolingSupplyAirDegF Integer32
  tlpCoolingReturnAirDegF Integer32
  tlpCoolingCondenserInletDegF Integer32
  tlpCoolingEvaporatorDegF Integer32
  tlpCoolingSuctionDegF Integer32
  tlpCoolingRemoteDegF Integer32
  tlpCoolingCondenserOutletDegF Integer32

TlpCoolingTemperatureCelsiusEntry  
SEQUENCE    
  tlpCoolingAmbientDegC Integer32
  tlpCoolingSupplyAirDegC Integer32
  tlpCoolingReturnAirDegC Integer32
  tlpCoolingCondenserInletDegC Integer32
  tlpCoolingEvaporatorDegC Integer32
  tlpCoolingSuctionDegC Integer32
  tlpCoolingRemoteDegC Integer32
  tlpCoolingCondenserOutletDegC Integer32

TlpCoolingPressureMpaEntry  
SEQUENCE    
  tlpCoolingSuctionPressureMpa Unsigned32
  tlpCoolingDischargePressureMpa Unsigned32

TlpCoolingPressurePsiEntry  
SEQUENCE    
  tlpCoolingSuctionPressurePsi Unsigned32
  tlpCoolingDischargePressurePsi Unsigned32

TlpCoolingDynamicEntry  
SEQUENCE    
  tlpCoolingEvaporatorFanSpeed INTEGER
  tlpCoolingCondenserFanSpeed INTEGER
  tlpCoolingCompressorFrequency Unsigned32
  tlpCoolingEEVSteps INTEGER

TlpCoolingRuntimeEntry  
SEQUENCE    
  tlpCoolingCompressorRunDays Unsigned32
  tlpCoolingCondensatePumpRunDays Unsigned32
  tlpCoolingAirFilterRunHours Unsigned32
  tlpCoolingEvaporatorFanRunDays Unsigned32
  tlpCoolingCondenserFanRunDays Unsigned32
  tlpCoolingAtomizerRunDays Unsigned32

TlpCoolingStatusEntry  
SEQUENCE    
  tlpCoolingOperatingMode INTEGER
  tlpCoolingCoolOutput Unsigned32
  tlpCoolingAlarmStatus INTEGER
  tlpCoolingCompressorStatus INTEGER
  tlpCoolingWaterStatus INTEGER

TlpCoolingControlEntry  
SEQUENCE    
  tlpCoolingOnOff INTEGER

TlpCoolingConfigEntry  
SEQUENCE    
  tlpCoolingAutoStart INTEGER
  tlpCoolingFanSpeed INTEGER
  tlpCoolingControlType INTEGER
  tlpCoolingDisplayUnits INTEGER
  tlpCoolingBeepOnKey INTEGER
  tlpCoolingInputContactType INTEGER
  tlpCoolingOutputContactType INTEGER
  tlpCoolingOutputRelaySource INTEGER
  tlpCoolingOutputRelayDefault INTEGER
  tlpCoolingOffOnInputContact INTEGER
  tlpCoolingOffOnLeak INTEGER
  tlpCoolingWaterLeakContactType INTEGER
  tlpCoolingAirFilterInterval Unsigned32
  tlpCoolingAirFilterAlarm INTEGER
  tlpCoolingMaxAirFilterRunHours Unsigned32
  tlpCoolingStartTimer Unsigned32
  tlpCoolingStopTimer Unsigned32
  tlpCoolingEnergyMode INTEGER
  tlpCoolingDefrostMode INTEGER
  tlpCoolingRemoteTemperatureSensor INTEGER
  tlpCoolingDehumidifyingMode INTEGER
  tlpCoolingFanAlwaysOn INTEGER
  tlpCoolingQuietMode INTEGER
  tlpCoolingHotGasBypass INTEGER
  tlpCoolingAutoFanSpeed INTEGER

TlpCoolingConfigTemperatureFahrenheitEntry  
SEQUENCE    
  tlpCoolingSetPointDegF Integer32
  tlpCoolingSupplyAirHighLimitDegF Integer32
  tlpCoolingSupplyAirLowLimitDegF Integer32
  tlpCoolingMaxDeviationLimitDegF Integer32
  tlpCoolingReturnAirHighLimitDegF Integer32
  tlpCoolingReturnAirLowLimitDegF Integer32
  tlpCoolingRemoteSetPointDegF Integer32

TlpCoolingConfigTemperatureCelsiusEntry  
SEQUENCE    
  tlpCoolingSetPointDegC Integer32
  tlpCoolingSupplyAirHighLimitDegC Integer32
  tlpCoolingSupplyAirLowLimitDegC Integer32
  tlpCoolingMaxDeviationLimitDegC Integer32
  tlpCoolingReturnAirHighLimitDegC Integer32
  tlpCoolingReturnAirLowLimitDegC Integer32
  tlpCoolingRemoteSetPointDegC Integer32

TlpAgentEmailContactEntry  
SEQUENCE    
  tlpAgentEmailContactIndex Unsigned32
  tlpAgentEmailContactRowStatus RowStatus
  tlpAgentEmailContactName DisplayString
  tlpAgentEmailContactAddress DisplayString

TlpAgentSnmpContactEntry  
SEQUENCE    
  tlpAgentSnmpContactIndex Unsigned32
  tlpAgentSnmpContactRowStatus RowStatus
  tlpAgentSnmpContactName DisplayString
  tlpAgentSnmpContactIpAddress DisplayString
  tlpAgentSnmpContactPort Unsigned32
  tlpAgentSnmpContactSnmpVersion INTEGER
  tlpAgentSnmpContactSecurityName DisplayString
  tlpAgentSnmpContactPrivPassword DisplayString
  tlpAgentSnmpContactAuthPassword DisplayString

TlpDeviceAlarmEntry  
SEQUENCE    
  tlpAlarmId Unsigned32
  tlpAlarmDescr OBJECT IDENTIFIER
  tlpAlarmTime TimeStamp
  tlpAlarmTableRef OBJECT IDENTIFIER
  tlpAlarmTableRowRef OBJECT IDENTIFIER
  tlpAlarmDetail DisplayString
  tlpAlarmType INTEGER
  tlpAlarmState INTEGER
  tlpAlarmAcknowledged INTEGER

TlpAlarmControlEntry  
SEQUENCE    
  tlpAlarmControlIndex Unsigned32
  tlpAlarmControlDescr OBJECT IDENTIFIER
  tlpAlarmControlDetail DisplayString
  tlpAlarmControlSeverity INTEGER

Defined Values

tlpProducts 1.3.6.1.4.1.850.1
This MIB module defines MIB objects which provide mechanisms for remote management capabilities of Tripp Lite PowerAlert and related software.
MODULE-IDENTITY    

tlpHardware 1.3.6.1.4.1.850.1.1
OBJECT IDENTIFIER    

tlpSoftware 1.3.6.1.4.1.850.1.2
OBJECT IDENTIFIER    

tlpAlarms 1.3.6.1.4.1.850.1.3
OBJECT IDENTIFIER    

tlpNotify 1.3.6.1.4.1.850.1.4
OBJECT IDENTIFIER    

tlpDevice 1.3.6.1.4.1.850.1.1.1
OBJECT IDENTIFIER    

tlpDeviceDetail 1.3.6.1.4.1.850.1.1.2
OBJECT IDENTIFIER    

tlpDeviceTypes 1.3.6.1.4.1.850.1.1.3
OBJECT IDENTIFIER    

tlpUps 1.3.6.1.4.1.850.1.1.3.1
OBJECT IDENTIFIER    

tlpPdu 1.3.6.1.4.1.850.1.1.3.2
OBJECT IDENTIFIER    

tlpEnvirosense 1.3.6.1.4.1.850.1.1.3.3
OBJECT IDENTIFIER    

tlpAts 1.3.6.1.4.1.850.1.1.3.4
OBJECT IDENTIFIER    

tlpCooling 1.3.6.1.4.1.850.1.1.3.5
OBJECT IDENTIFIER    

tlpKvm 1.3.6.1.4.1.850.1.1.3.6
OBJECT IDENTIFIER    

tlpRackTrack 1.3.6.1.4.1.850.1.1.3.7
OBJECT IDENTIFIER    

tlpSwitch 1.3.6.1.4.1.850.1.1.3.8
OBJECT IDENTIFIER    

tlpUpsIdent 1.3.6.1.4.1.850.1.1.3.1.1
OBJECT IDENTIFIER    

tlpUpsDevice 1.3.6.1.4.1.850.1.1.3.1.2
OBJECT IDENTIFIER    

tlpUpsDetail 1.3.6.1.4.1.850.1.1.3.1.3
OBJECT IDENTIFIER    

tlpUpsControl 1.3.6.1.4.1.850.1.1.3.1.4
OBJECT IDENTIFIER    

tlpUpsConfig 1.3.6.1.4.1.850.1.1.3.1.5
OBJECT IDENTIFIER    

tlpUpsBattery 1.3.6.1.4.1.850.1.1.3.1.3.1
OBJECT IDENTIFIER    

tlpUpsInput 1.3.6.1.4.1.850.1.1.3.1.3.2
OBJECT IDENTIFIER    

tlpUpsOutput 1.3.6.1.4.1.850.1.1.3.1.3.3
OBJECT IDENTIFIER    

tlpUpsBypass 1.3.6.1.4.1.850.1.1.3.1.3.4
OBJECT IDENTIFIER    

tlpUpsOutlet 1.3.6.1.4.1.850.1.1.3.1.3.5
OBJECT IDENTIFIER    

tlpUpsWatchdog 1.3.6.1.4.1.850.1.1.3.1.3.6
OBJECT IDENTIFIER    

tlpUpsFan 1.3.6.1.4.1.850.1.1.3.1.3.7
OBJECT IDENTIFIER    

tlpPduIdent 1.3.6.1.4.1.850.1.1.3.2.1
OBJECT IDENTIFIER    

tlpPduDevice 1.3.6.1.4.1.850.1.1.3.2.2
OBJECT IDENTIFIER    

tlpPduDetail 1.3.6.1.4.1.850.1.1.3.2.3
OBJECT IDENTIFIER    

tlpPduControl 1.3.6.1.4.1.850.1.1.3.2.4
OBJECT IDENTIFIER    

tlpPduConfig 1.3.6.1.4.1.850.1.1.3.2.5
OBJECT IDENTIFIER    

tlpPduInput 1.3.6.1.4.1.850.1.1.3.2.3.1
OBJECT IDENTIFIER    

tlpPduOutput 1.3.6.1.4.1.850.1.1.3.2.3.2
OBJECT IDENTIFIER    

tlpPduOutlet 1.3.6.1.4.1.850.1.1.3.2.3.3
OBJECT IDENTIFIER    

tlpPduCircuit 1.3.6.1.4.1.850.1.1.3.2.3.4
OBJECT IDENTIFIER    

tlpPduBreaker 1.3.6.1.4.1.850.1.1.3.2.3.5
OBJECT IDENTIFIER    

tlpPduHeatsink 1.3.6.1.4.1.850.1.1.3.2.3.6
OBJECT IDENTIFIER    

tlpEnvIdent 1.3.6.1.4.1.850.1.1.3.3.1
OBJECT IDENTIFIER    

tlpEnvDetail 1.3.6.1.4.1.850.1.1.3.3.3
OBJECT IDENTIFIER    

tlpEnvConfig 1.3.6.1.4.1.850.1.1.3.3.5
OBJECT IDENTIFIER    

tlpAtsIdent 1.3.6.1.4.1.850.1.1.3.4.1
OBJECT IDENTIFIER    

tlpAtsDevice 1.3.6.1.4.1.850.1.1.3.4.2
OBJECT IDENTIFIER    

tlpAtsDetail 1.3.6.1.4.1.850.1.1.3.4.3
OBJECT IDENTIFIER    

tlpAtsControl 1.3.6.1.4.1.850.1.1.3.4.4
OBJECT IDENTIFIER    

tlpAtsConfig 1.3.6.1.4.1.850.1.1.3.4.5
OBJECT IDENTIFIER    

tlpAtsInput 1.3.6.1.4.1.850.1.1.3.4.3.1
OBJECT IDENTIFIER    

tlpAtsOutput 1.3.6.1.4.1.850.1.1.3.4.3.2
OBJECT IDENTIFIER    

tlpAtsOutlet 1.3.6.1.4.1.850.1.1.3.4.3.3
OBJECT IDENTIFIER    

tlpAtsCircuit 1.3.6.1.4.1.850.1.1.3.4.3.4
OBJECT IDENTIFIER    

tlpAtsBreaker 1.3.6.1.4.1.850.1.1.3.4.3.5
OBJECT IDENTIFIER    

tlpAtsHeatsink 1.3.6.1.4.1.850.1.1.3.4.3.6
OBJECT IDENTIFIER    

tlpCoolingIdent 1.3.6.1.4.1.850.1.1.3.5.1
OBJECT IDENTIFIER    

tlpCoolingDevice 1.3.6.1.4.1.850.1.1.3.5.2
OBJECT IDENTIFIER    

tlpCoolingDetail 1.3.6.1.4.1.850.1.1.3.5.3
OBJECT IDENTIFIER    

tlpCoolingControl 1.3.6.1.4.1.850.1.1.3.5.4
OBJECT IDENTIFIER    

tlpCoolingConfig 1.3.6.1.4.1.850.1.1.3.5.5
OBJECT IDENTIFIER    

tlpCoolingTemperature 1.3.6.1.4.1.850.1.1.3.5.3.1
OBJECT IDENTIFIER    

tlpCoolingPressure 1.3.6.1.4.1.850.1.1.3.5.3.2
OBJECT IDENTIFIER    

tlpKvmIdent 1.3.6.1.4.1.850.1.1.3.6.1
OBJECT IDENTIFIER    

tlpKvmDevice 1.3.6.1.4.1.850.1.1.3.6.2
OBJECT IDENTIFIER    

tlpKvmDetail 1.3.6.1.4.1.850.1.1.3.6.3
OBJECT IDENTIFIER    

tlpKvmControl 1.3.6.1.4.1.850.1.1.3.6.4
OBJECT IDENTIFIER    

tlpKvmConfig 1.3.6.1.4.1.850.1.1.3.6.5
OBJECT IDENTIFIER    

tlpRackTrackIdent 1.3.6.1.4.1.850.1.1.3.7.1
OBJECT IDENTIFIER    

tlpRackTrackDevice 1.3.6.1.4.1.850.1.1.3.7.2
OBJECT IDENTIFIER    

tlpRackTrackDetail 1.3.6.1.4.1.850.1.1.3.7.3
OBJECT IDENTIFIER    

tlpRackTrackControl 1.3.6.1.4.1.850.1.1.3.7.4
OBJECT IDENTIFIER    

tlpRackTrackConfig 1.3.6.1.4.1.850.1.1.3.7.5
OBJECT IDENTIFIER    

tlpSwitchIdent 1.3.6.1.4.1.850.1.1.3.8.1
OBJECT IDENTIFIER    

tlpSwitchDevice 1.3.6.1.4.1.850.1.1.3.8.2
OBJECT IDENTIFIER    

tlpSwitchDetail 1.3.6.1.4.1.850.1.1.3.8.3
OBJECT IDENTIFIER    

tlpSwitchControl 1.3.6.1.4.1.850.1.1.3.8.4
OBJECT IDENTIFIER    

tlpSwitchConfig 1.3.6.1.4.1.850.1.1.3.8.5
OBJECT IDENTIFIER    

tlpAgentDetails 1.3.6.1.4.1.850.1.2.1
OBJECT IDENTIFIER    

tlpAgentSettings 1.3.6.1.4.1.850.1.2.2
OBJECT IDENTIFIER    

tlpAgentContacts 1.3.6.1.4.1.850.1.2.3
OBJECT IDENTIFIER    

tlpAgentIdent 1.3.6.1.4.1.850.1.2.1.1
OBJECT IDENTIFIER    

tlpAgentAttributes 1.3.6.1.4.1.850.1.2.1.2
OBJECT IDENTIFIER    

tlpAgentConfig 1.3.6.1.4.1.850.1.2.2.1
OBJECT IDENTIFIER    

tlpAgentEmailContacts 1.3.6.1.4.1.850.1.2.3.1
OBJECT IDENTIFIER    

tlpAgentSnmpContacts 1.3.6.1.4.1.850.1.2.3.2
OBJECT IDENTIFIER    

tlpAlarmsWellKnown 1.3.6.1.4.1.850.1.3.3
OBJECT IDENTIFIER    

tlpAlarmControl 1.3.6.1.4.1.850.1.3.4
OBJECT IDENTIFIER    

tlpAgentAlarms 1.3.6.1.4.1.850.1.3.3.1
OBJECT IDENTIFIER    

tlpDeviceAlarms 1.3.6.1.4.1.850.1.3.3.2
OBJECT IDENTIFIER    

tlpUpsAlarms 1.3.6.1.4.1.850.1.3.3.3
OBJECT IDENTIFIER    

tlpPduAlarms 1.3.6.1.4.1.850.1.3.3.4
OBJECT IDENTIFIER    

tlpEnvAlarms 1.3.6.1.4.1.850.1.3.3.5
OBJECT IDENTIFIER    

tlpAtsAlarms 1.3.6.1.4.1.850.1.3.3.6
OBJECT IDENTIFIER    

tlpCoolingAlarms 1.3.6.1.4.1.850.1.3.3.7
OBJECT IDENTIFIER    

tlpKvmAlarms 1.3.6.1.4.1.850.1.3.3.8
OBJECT IDENTIFIER    

tlpRackTrackAlarms 1.3.6.1.4.1.850.1.3.3.9
OBJECT IDENTIFIER    

tlpSwitchAlarms 1.3.6.1.4.1.850.1.3.3.10
OBJECT IDENTIFIER    

tlpNotifications 1.3.6.1.4.1.850.1.4.1
OBJECT IDENTIFIER    

tlpNotificationsEvent 1.3.6.1.4.1.850.1.4.2
OBJECT IDENTIFIER    

tlpNotificationsEventParameters 1.3.6.1.4.1.850.1.4.3
OBJECT IDENTIFIER    

tlpDeviceNumDevices 1.3.6.1.4.1.850.1.1.1.1
The number of devices that this agent is currently managing.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpDeviceTable 1.3.6.1.4.1.850.1.1.1.2
A list of device table entries. The number of entries is given by the value of tlpDevicesNumDevices.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpDeviceEntry

tlpDeviceEntry 1.3.6.1.4.1.850.1.1.1.2.1
An entry containing information applicable to a particular device managed by this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpDeviceEntry  

tlpDeviceIndex 1.3.6.1.4.1.850.1.1.1.2.1.1
The table row index for the device.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpDeviceRowStatus 1.3.6.1.4.1.850.1.1.1.2.1.2
Used with table edits to indicate the status of a given row in tlpDeviceTable.
Status: current Access: read-only
OBJECT-TYPE    
  RowStatus  

tlpDeviceType 1.3.6.1.4.1.850.1.1.1.2.1.3
The type of device. One of the appropriate hardware types: ups, pdu, envirosense, etc.
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

tlpDeviceManufacturer 1.3.6.1.4.1.850.1.1.1.2.1.4
The name of the manufacturer.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

tlpDeviceModel 1.3.6.1.4.1.850.1.1.1.2.1.5
The model designation.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

tlpDeviceName 1.3.6.1.4.1.850.1.1.1.2.1.6
A user-supplied name for the device.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

tlpDeviceID 1.3.6.1.4.1.850.1.1.1.2.1.7
A user-supplied ID for the device.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

tlpDeviceLocation 1.3.6.1.4.1.850.1.1.1.2.1.8
A user-supplied location for the device.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

tlpDeviceRegion 1.3.6.1.4.1.850.1.1.1.2.1.9
A user-supplied region for the device.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

tlpDeviceStatus 1.3.6.1.4.1.850.1.1.1.2.1.10
The currently most critical alarm status for the device.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), critical(1), warning(2), info(3), status(4), offline(5), custom(6), configuration(7)  

tlpDeviceIdentTable 1.3.6.1.4.1.850.1.1.2.1
The identity details of each device in device table. The number of entries is given by the value of tlpDevicesNumDevices.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpDeviceIdentEntry

tlpDeviceIdentEntry 1.3.6.1.4.1.850.1.1.2.1.1
An entry containing details for a particular device.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpDeviceIdentEntry  

tlpDeviceIdentProtocol 1.3.6.1.4.1.850.1.1.2.1.1.1
The Tripplite protocol used to communicate with the device.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

tlpDeviceIdentCommPortType 1.3.6.1.4.1.850.1.1.2.1.1.2
The type of communications port used to connect with the device.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), serial(1), usb(2), hid(3), simulated(4), unittest(5)  

tlpDeviceIdentCommPortName 1.3.6.1.4.1.850.1.1.2.1.1.3
The name of the communications port.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

tlpDeviceIdentFirmwareVersion 1.3.6.1.4.1.850.1.1.2.1.1.4
The firmware version of the device.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

tlpDeviceIdentSerialNum 1.3.6.1.4.1.850.1.1.2.1.1.5
The serial number of the device.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

tlpDeviceIdentDateInstalled 1.3.6.1.4.1.850.1.1.2.1.1.6
The installation date for this device in the format of mm/dd/yyyy.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

tlpDeviceIdentHardwareVersion 1.3.6.1.4.1.850.1.1.2.1.1.7
The hardware revision of the device. This value will return ERROR_NO_SUCH_NAME if not supported by the device.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

tlpDeviceIdentCurrentUptime 1.3.6.1.4.1.850.1.1.2.1.1.8
The device uptime since its last startup. The format of this value is a comma- delimited string representing days, hours and minutes. For example, the value of 123,4,5 represents 123 days, 4 hours and 5 minutes. This value will return ERROR_NO_SUCH_NAME if not supported by the device.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

tlpDeviceIdentTotalUptime 1.3.6.1.4.1.850.1.1.2.1.1.9
The cumulative (total) uptime for the device. The format of this value is a comma- delimited string representing days, hours and minutes. For example, the value of 123,4,5 represents 123 days, 4 hours and 5 minutes. This value will return ERROR_NO_SUCH_NAME if not supported by the device.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

tlpDeviceIdentFirmwareVersion2 1.3.6.1.4.1.850.1.1.2.1.1.10
The firmware version of second IC on the device. This value will return ERROR_NO_SUCH_NAME if not supported by the device.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

tlpDeviceIdentFirmwareVersion3 1.3.6.1.4.1.850.1.1.2.1.1.11
The firmware version of third IC on the device. This value will return ERROR_NO_SUCH_NAME if not supported by the device.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

tlpDeviceIdentNvrID 1.3.6.1.4.1.850.1.1.2.1.1.12
The id of NVRAM. This value will return ERROR_NO_SUCH_NAME if not supported by the device.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

tlpUpsIdentNumUps 1.3.6.1.4.1.850.1.1.3.1.1.1
The number of ups devices that this agent is currently managing.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsIdentTable 1.3.6.1.4.1.850.1.1.3.1.1.2
The identity details of each ups in device table. This is a sparse dependent table, and will contain some subset of devices that are upss.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpUpsIdentEntry

tlpUpsIdentEntry 1.3.6.1.4.1.850.1.1.3.1.1.2.1
An entry containing details for a particular ups.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpUpsIdentEntry  

tlpUpsIdentNumInputs 1.3.6.1.4.1.850.1.1.3.1.1.2.1.1
The number of input lines supported by the ups.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsIdentNumOutputs 1.3.6.1.4.1.850.1.1.3.1.1.2.1.2
The number of output lines supported by the ups.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsIdentNumBypass 1.3.6.1.4.1.850.1.1.3.1.1.2.1.3
The number of bypass lines supported by the ups.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsIdentNumPhases 1.3.6.1.4.1.850.1.1.3.1.1.2.1.4
The number of phases supported by the ups.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsIdentNumOutlets 1.3.6.1.4.1.850.1.1.3.1.1.2.1.5
The number of receptacles supported by the ups.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsIdentNumOutletGroups 1.3.6.1.4.1.850.1.1.3.1.1.2.1.6
The number of receptacle groups supported by the ups.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsIdentNumBatteryPacks 1.3.6.1.4.1.850.1.1.3.1.1.2.1.7
The number of battery packs, internal and external combined, supported by the ups.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsIdentNumFans 1.3.6.1.4.1.850.1.1.3.1.1.2.1.8
The number of fans supported by the ups.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsSupportsTable 1.3.6.1.4.1.850.1.1.3.1.1.3
The supported details of each ups in device table. This is a sparse dependent table, and will contain some subset of devices that are upss.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpUpsSupportsEntry

tlpUpsSupportsEntry 1.3.6.1.4.1.850.1.1.3.1.1.3.1
An entry containing supported details for a particular ups.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpUpsSupportsEntry  

tlpUpsSupportsEnergywise 1.3.6.1.4.1.850.1.1.3.1.1.3.1.1
Indicates whether the ups supports Cisco EnergyWise.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpUpsSupportsRampShed 1.3.6.1.4.1.850.1.1.3.1.1.3.1.2
Indicates whether the ups supports ramping and shedding.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpUpsSupportsOutletGroup 1.3.6.1.4.1.850.1.1.3.1.1.3.1.3
Indicates whether the ups supports outlet groups.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpUpsSupportsOutletCurrentPower 1.3.6.1.4.1.850.1.1.3.1.1.3.1.4
Indicates whether the ups reports individual receptacle current and power measurements. Devices that do not support individual receptacle measurements will always return ERROR_NO_SUCH_NAME for tlpUpsOutletCurrent and tlpUpsOutletPower.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpUpsSupportsOutletVoltage 1.3.6.1.4.1.850.1.1.3.1.1.3.1.5
Indicates whether the ups reports individual receptacle voltage measurements. Devices that do not support individual receptacle measurements will always return ERROR_NO_SUCH_NAME for tlpUpsOutletVoltage.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpUpsDeviceTable 1.3.6.1.4.1.850.1.1.3.1.2.1
The device details of each ups in device table. This is a sparse dependent table, and will contain some subset of devices that are upss.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpUpsDeviceEntry

tlpUpsDeviceEntry 1.3.6.1.4.1.850.1.1.3.1.2.1.1
An entry containing device details for a particular ups.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpUpsDeviceEntry  

tlpUpsDeviceMainLoadState 1.3.6.1.4.1.850.1.1.3.1.2.1.1.1
The current state of the main output of the device.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), off(1), on(2)  

tlpUpsDeviceMainLoadControllable 1.3.6.1.4.1.850.1.1.3.1.2.1.1.2
Indicates whether or not the main output is controllable, and whether the ups can be turned off and on.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpUpsDeviceMainLoadCommand 1.3.6.1.4.1.850.1.1.3.1.2.1.1.3
Reading this value will always return 0. Setting this value to turnOff(1) will turn off the main output of the ups. Setting this value to turnOn(2) will turn on the main output of the ups. Setting this value to cycle(3) will turn off the main output, then turn it back on.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER idle(0), turnOff(1), turnOn(2), cycle(3)  

tlpUpsDevicePowerOnDelay 1.3.6.1.4.1.850.1.1.3.1.2.1.1.4
The configurable delay value, which sets the amount of additional time a given device will wait before it connects to a valid AC source. By default the delay value is set to 0.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tlpUpsDeviceTestDate 1.3.6.1.4.1.850.1.1.3.1.2.1.1.5
The date of the last self-test run on the ups, in the format YYYY-MM-DD.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

tlpUpsDeviceTestResultsStatus 1.3.6.1.4.1.850.1.1.3.1.2.1.1.6
The result of the last self-test run on the ups.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noTest(0), doneAndPassed(1), doneAndWarning(2), doneAndError(3), aborted(4), inProgress(5), noTestInitiated(6), badBattery(7), overCurrent(8), batteryFailed(9)  

tlpUpsDeviceTemperatureC 1.3.6.1.4.1.850.1.1.3.1.2.1.1.7
The ambient temperature at or near the ups casing. Temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpUpsDeviceTemperatureF 1.3.6.1.4.1.850.1.1.3.1.2.1.1.8
The ambient temperature at or near the ups casing. Temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpUpsDeviceLastACFailureReason 1.3.6.1.4.1.850.1.1.3.1.2.1.1.9
The last AC failure reason.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noACFailureSinceReset(0), blackout(1), instantaneousHighLineFrequency(2), highLineVoltage(3), lowLineVoltage(4), averageFrequencyFault(5), instantaneousLowLineFrequency(6), delayedBrownout(7)  

tlpUpsDeviceLastShutdownReason 1.3.6.1.4.1.850.1.1.3.1.2.1.1.10
The last unit shut down reason.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noShutdownSinceReset(0), onOffButtonShutdown(1), averageVbattSmallerThenLVCShutdown(2), fastVbattKeepaliveVoltageFastShutdown(3), averageCurrentLimitShutdown(4), fastCurrentLimitShutdown(5), heavyLoadThermalTimeLimitShutdown(6), fixedInvertModeTimeLimitShutdown(7), highBatteryVoltageFault(8), averageVbattKeepaliveVoltageShutdown(9), shutdownCommandWithAutorestartEnabled(10), shutdownCommandWithoutAutorestartEnabled(11), lineConnectRelayFault(12), epoInvertMode(13), epoRebootMode(14), invalidLineStandbyMode(15), chargerLimitMinBatteryVoltage(16), chargerLimitMaxBatteryVoltage(17), invalidLineDelayedWakeupAutorestartEnabled(18), invalidLineDelayedWakeupAutorestartDisabled(19), minBatteryVoltagePriorDelayedWakeupAutorestartEnabled(20), minBatteryVoltagePriorDelayedWakeupAutorestartDisabled(21), lvcShutdownAutorestartEnabled(22), lvcShutdownAutorestartDisabled(23), overloadShutdownAutorestartEnabled(24), overloadShutdownAutorestartDisabled(25), overTemperatureShutdownAutorestartEnabled(26), overTemperatureShutdownAutorestartDisabled(27), onOffButtonShutdownAutorestartEnabled(28), onOffButtonShutdownAutorestartDisabled(29), batteryReportedFault(30), batteryCommunicationLost(31), batteryJumpStartChargerTimeoutError(32)  

tlpUpsDeviceOutputCurrentPrecision 1.3.6.1.4.1.850.1.1.3.1.2.1.1.11
Output current is reported by tlpUpsOutputLineCurrent, tlpUpsOutputLineCurrentMin and tlpUpsOutputLineCurrentMax. These values are all reported in hundredths(0.01A),which accommodates all models; however, on any given device the actual precision may vary. This value describes the actual precision, which can be used as a divisor against the output current values to obtain the true output current measurement. For example, if tlpUpsOutputLineCurrent reports 530 and tlpUpsDeviceOutputCurrentPrecision is tenths(1), then the actual output current is 5.3.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER wholeNumber(0), tenths(1), hundredths(2)  

tlpUpsBatterySummaryTable 1.3.6.1.4.1.850.1.1.3.1.3.1.1
The battery system summary of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpUpsBatterySummaryEntry

tlpUpsBatterySummaryEntry 1.3.6.1.4.1.850.1.1.3.1.3.1.1.1
An entry containing information applicable to a particular battery system managed by this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpUpsBatterySummaryEntry  

tlpUpsBatteryStatus 1.3.6.1.4.1.850.1.1.3.1.3.1.1.1.1
The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than tlpUpsConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to tlpUpsConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), batteryNormal(2), batteryLow(3), batteryDepleted(4)  

tlpUpsSecondsOnBattery 1.3.6.1.4.1.850.1.1.3.1.3.1.1.1.2
If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsEstimatedMinutesRemaining 1.3.6.1.4.1.850.1.1.3.1.3.1.1.1.3
An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsEstimatedChargeRemaining 1.3.6.1.4.1.850.1.1.3.1.3.1.1.1.4
An estimate of the battery charge remaining expressed as a percent of full charge.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

tlpUpsBatteryRunTimeRemaining 1.3.6.1.4.1.850.1.1.3.1.3.1.1.1.5
The run time remaining before batteries are exhausted. If the device does not support run time remaining, then the agent reports ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

tlpUpsBatteryDetailTable 1.3.6.1.4.1.850.1.1.3.1.3.1.2
The battery detail of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpUpsBatteryDetailEntry

tlpUpsBatteryDetailEntry 1.3.6.1.4.1.850.1.1.3.1.3.1.2.1
An entry containing information applicable to a particular battery system managed by this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpUpsBatteryDetailEntry  

tlpUpsBatteryDetailVoltage 1.3.6.1.4.1.850.1.1.3.1.3.1.2.1.1
The magnitude of the present battery voltage.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsBatteryDetailCurrent 1.3.6.1.4.1.850.1.1.3.1.3.1.2.1.2
The present battery current.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpUpsBatteryDetailCapacity 1.3.6.1.4.1.850.1.1.3.1.3.1.2.1.3
The estimated remaining battery capacity expressed as a percent of full capacity.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

tlpUpsBatteryDetailCharge 1.3.6.1.4.1.850.1.1.3.1.3.1.2.1.4
Denotes the charge state of the battery.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER floating(0), charging(1), resting(2), discharging(3), normal(4), standby(5)  

tlpUpsBatteryDetailChargerStatus 1.3.6.1.4.1.850.1.1.3.1.3.1.2.1.5
The status of the battery charger. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ok(0), inFaultCondition(1)  

tlpUpsBatteryPackIdentTable 1.3.6.1.4.1.850.1.1.3.1.3.1.3
The battery identification details for each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by upsIdentNumUps and the number of battery battery packs per each as reported by tlpUpsNumBatteryPacks.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpUpsBatteryIdentEntry

tlpUpsBatteryPackIdentEntry 1.3.6.1.4.1.850.1.1.3.1.3.1.3.1
An entry containing information applicable to a particular battery pack managed by this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpUpsBatteryIdentEntry  

tlpUpsBatteryPackIdentIndex 1.3.6.1.4.1.850.1.1.3.1.3.1.3.1.1
The table row index for the ups battery pack.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsBatteryPackIdentManufacturer 1.3.6.1.4.1.850.1.1.3.1.3.1.3.1.2
The manufacturer of the battery pack. If the device does not support this value, then the agent reports ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

tlpUpsBatteryPackIdentModel 1.3.6.1.4.1.850.1.1.3.1.3.1.3.1.3
The model or device name of the battery pack. If the device does not support this value, then the agent reports ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

tlpUpsBatteryPackIdentSerialNum 1.3.6.1.4.1.850.1.1.3.1.3.1.3.1.4
The serial number of the battery pack. If the device does not support this value, then the agent reports ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

tlpUpsBatteryPackIdentFirmware 1.3.6.1.4.1.850.1.1.3.1.3.1.3.1.5
The firmware of the battery pack. If the device does not support this value, then the agent reports ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

tlpUpsBatteryPackIdentSKU 1.3.6.1.4.1.850.1.1.3.1.3.1.3.1.6
The SKU of the battery pack. If the device does not support this value, then the agent reports ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

tlpUpsBatteryPackConfigTable 1.3.6.1.4.1.850.1.1.3.1.3.1.4
The battery configuration details for each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by upsIdentNumUps and the number of battery battery packs per each as reported by tlpUpsNumBatteryPacks.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpUpsBatteryConfigEntry

tlpUpsBatteryPackConfigEntry 1.3.6.1.4.1.850.1.1.3.1.3.1.4.1
An entry containing information applicable to a particular battery pack managed by this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpUpsBatteryConfigEntry  

tlpUpsBatteryPackConfigChemistry 1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.1
The type of battery pack.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), leadAcid(1), nickelCadmium(2), lithiumIon(3)  

tlpUpsBatteryPackConfigStyle 1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.2
The style of battery pack.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), nonsmart(1), smart(2), bms(3)  

tlpUpsBatteryPackConfigLocation 1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.3
The location of the battery pack.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), internal(1), external(2)  

tlpUpsBatteryPackConfigStrings 1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.4
The number of series strings in parallel contained in the battery pack. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsBatteryPackConfigBatteriesPerString 1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.5
The number of battery per each string in the battery pack. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsBatteryPackConfigCellsPerBattery 1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.6
The number of cells per battery..
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), one(1), two(2), four(4), six(6)  

tlpUpsBatteryPackConfigNumBatteries 1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.7
The total number of batteries contained in the battery pack. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsBatteryPackConfigCapacityUnits 1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.8
The units of measurement used for tlpUpsBatteryPackConfigDesignCapacity and tlpUpsBatteryPackConfigCellCapacity. If supported, this value will report either mAHR(1), amps per hour, or mWhr(1), watts per hour. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER mAHr(0), mWHr(1)  

tlpUpsBatteryPackConfigDesignCapacity 1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.9
The theoretical or nominal capacity of the battery pack in the measurement defined by tlpUpsBatteryPackConfigCapacityUnits. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsBatteryPackConfigCellCapacity 1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.10
The capacity of the batteries in the measurement defined by tlpUpsBatteryPackConfigCapacityUnits. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsBatteryPackConfigMinCellVoltage 1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.11
The minimum cell voltage for the batteries. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsBatteryPackConfigMaxCellVoltage 1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.12
The maximum cell voltage for the batteries. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsBatteryPackDetailTable 1.3.6.1.4.1.850.1.1.3.1.3.1.5
The details of each battery pack for each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss and battery packs managed by the agent as reported by tlpUpsIdentNumUps and tlpUpsIdentNumBatteryPacks.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpUpsBatteryPackDetailEntry

tlpUpsBatteryPackDetailEntry 1.3.6.1.4.1.850.1.1.3.1.3.1.5.1
An entry containing information applicable to a particular battery system managed by this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpUpsBatteryPackDetailEntry  

tlpUpsBatteryPackDetailCondition 1.3.6.1.4.1.850.1.1.3.1.3.1.5.1.1
The condition of the battery. A bad battery should be replaced.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), good(1), weak(2), bad(3)  

tlpUpsBatteryPackDetailTemperatureC 1.3.6.1.4.1.850.1.1.3.1.3.1.5.1.2
The ambient temperature at or near the UPS Battery casing.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsBatteryPackDetailTemperatureF 1.3.6.1.4.1.850.1.1.3.1.3.1.5.1.3
The ambient temperature at or near the UPS Battery casing.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsBatteryPackDetailAge 1.3.6.1.4.1.850.1.1.3.1.3.1.5.1.4
The age of the battery in years. This is equal to the current date minus tlpUpsBatteryPackIdentInstallDate.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsBatteryPackDetailLastReplaceDate 1.3.6.1.4.1.850.1.1.3.1.3.1.5.1.5
The date when the batteries were last replaced in YYYYMMDD format.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

tlpUpsBatteryPackDetailNextReplaceDate 1.3.6.1.4.1.850.1.1.3.1.3.1.5.1.6
The date when the batteries should next be replaced in YYYYMMDD format.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

tlpUpsBatteryPackDetailCycleCount 1.3.6.1.4.1.850.1.1.3.1.3.1.5.1.7
The number of times the battery went into invert mode. This number is incremented by 1 each time the unit goes on battery mode (with the exception of Self Test mode). If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsInputTable 1.3.6.1.4.1.850.1.1.3.1.3.2.1
The input details of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpUpsInputEntry

tlpUpsInputEntry 1.3.6.1.4.1.850.1.1.3.1.3.2.1.1
An entry containing information applicable to all input lines per each ups managed by this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpUpsInputEntry  

tlpUpsInputLineBads 1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.1
A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. This value is not supported on all units. If the ups does not support this value, then the agent reports ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

tlpUpsInputNominalVoltage 1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.2
The nominal value of the input line voltage. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsInputNominalFrequency 1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.3
The nominal value of the input line frequency. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsInputLowTransferVoltage 1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.4
The minimum line voltage allowed before the ups system transfers to battery backup.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsInputLowTransferVoltageLowerBound 1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.5
The lower boundary value of tlpUpsInputLowTransferVoltage as dictated by the hardware of the unit.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsInputLowTransferVoltageUpperBound 1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.6
The upper boundary value of tlpUpsInputLowTransferVoltage as dictated by the hardware of the unit.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsInputHighTransferVoltage 1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.7
The maximum line voltage allowed before the ups system transfers to battery backup.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsInputHighTransferVoltageLowerBound 1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.8
The lower boundary value of tlpUpsInputHighTransferVoltage as dictated by the hardware of the unit.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsInputHighTransferVoltageUpperBound 1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.9
The upper boundary value of tlpUpsInputHighTransferVoltage as dictated by the hardware of the unit.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsInputWattHours 1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.10
The number of watt hours of energy utilized in the past 24 hours. Use tlpUpsControlResetWattHours to reset the watt hours calculation algorithm.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsInputPhaseTable 1.3.6.1.4.1.850.1.1.3.1.3.2.2
The input phase details of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps and tlpUpsIdentNumPhases.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpUpsInputPhaseEntry

tlpUpsInputPhaseEntry 1.3.6.1.4.1.850.1.1.3.1.3.2.2.1
An entry containing information applicable to a particular input phase managed by this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpUpsInputPhaseEntry  

tlpUpsInputPhaseIndex 1.3.6.1.4.1.850.1.1.3.1.3.2.2.1.1
The table row index for the ups input phase.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsInputPhaseFrequency 1.3.6.1.4.1.850.1.1.3.1.3.2.2.1.2
The present input frequency for a given input line.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsInputPhaseVoltage 1.3.6.1.4.1.850.1.1.3.1.3.2.2.1.3
The magnitude of the present input voltage for a given input line.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsInputPhaseVoltageMin 1.3.6.1.4.1.850.1.1.3.1.3.2.2.1.4
The minimum input voltage value since the last reset of this value for a given input line. If any value is written to either tlpUpsInputVoltageMin or tlpUpsInputVoltageMax, both will be reset to their appropriate minimum and maximum values.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpUpsInputPhaseVoltageMax 1.3.6.1.4.1.850.1.1.3.1.3.2.2.1.5
The maximum input voltage value since the last reset of this value for a given input line. If any value is written to either tlpUpsInputVoltageMin or tlpUpsInputVoltageMax, both will be reset to their appropriate minimum and maximum values.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpUpsInputPhaseCurrent 1.3.6.1.4.1.850.1.1.3.1.3.2.2.1.6
The magnitude of the present input current.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsInputPhasePower 1.3.6.1.4.1.850.1.1.3.1.3.2.2.1.7
The magnitude of the present input true power.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsOutputTable 1.3.6.1.4.1.850.1.1.3.1.3.3.1
The output details of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpUpsOutputEntry

tlpUpsOutputEntry 1.3.6.1.4.1.850.1.1.3.1.3.3.1.1
An entry containing information applicable to a particular output line managed by this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpUpsOutputEntry  

tlpUpsOutputSource 1.3.6.1.4.1.850.1.1.3.1.3.3.1.1.1
The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), other(1), none(2), normal(3), bypass(4), battery(5), boosting(6), reducing(7), second(8), economy(9)  

tlpUpsOutputNominalVoltage 1.3.6.1.4.1.850.1.1.3.1.3.3.1.1.2
The nominal value of the output voltage. This value may not be supported on all models. If not supported, the agent reports ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsOutputFrequency 1.3.6.1.4.1.850.1.1.3.1.3.3.1.1.3
The present output frequency. The output frequency on most ups devices is common across all output lines. Some ups devices, however, maintain the output frequency per each line. If a common frequency is supported by the ups, then this frequency will contain the common frequency value. If not supported, the agent reports ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsOutputVARating 1.3.6.1.4.1.850.1.1.3.1.3.3.1.1.4
The VA Rating of the ups. This value may not be supported on all models. If not supported, the agent reports ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsOutputLineTable 1.3.6.1.4.1.850.1.1.3.1.3.3.2
The output line details of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpUpsOutputLineEntry

tlpUpsOutputLineEntry 1.3.6.1.4.1.850.1.1.3.1.3.3.2.1
An entry containing information applicable to a particular output line managed by this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpUpsOutputLineEntry  

tlpUpsOutputLineIndex 1.3.6.1.4.1.850.1.1.3.1.3.3.2.1.1
The table row index for the ups output line.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsOutputLineVoltage 1.3.6.1.4.1.850.1.1.3.1.3.3.2.1.2
The magnitude of the present output voltage for a given output line.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsOutputLineCurrent 1.3.6.1.4.1.850.1.1.3.1.3.3.2.1.3
The output current, in hundredths of amps, for a given line. The actual precision of this value, whether a whole number, tenths or hundredths, is returned by tlpUpsDeviceOutputCurrentPrecision.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsOutputLinePower 1.3.6.1.4.1.850.1.1.3.1.3.3.2.1.4
The present output true power.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsOutputLinePercentLoad 1.3.6.1.4.1.850.1.1.3.1.3.3.2.1.5
The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..200  

tlpUpsOutputLineFrequency 1.3.6.1.4.1.850.1.1.3.1.3.3.2.1.6
The present output frequency on this output line. The output frequency on most ups devices is common across all output lines. Some ups devices, however, maintain the output frequency per each line. If a per line frequency is supported by the ups, then this frequency value will reports the value of this line. If not supported, the agent reports ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsBypassTable 1.3.6.1.4.1.850.1.1.3.1.3.4.1
The bypass details of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpUpsBypassEntry

tlpUpsBypassEntry 1.3.6.1.4.1.850.1.1.3.1.3.4.1.1
An entry containing information applicable to all input lines per each ups managed by this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpUpsBypassEntry  

tlpUpsBypassFrequency 1.3.6.1.4.1.850.1.1.3.1.3.4.1.1.1
The present bypass frequency.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsBypassLineTable 1.3.6.1.4.1.850.1.1.3.1.3.4.2
The bypass line details of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpUpsBypassLineEntry

tlpUpsBypassLineEntry 1.3.6.1.4.1.850.1.1.3.1.3.4.2.1
An entry containing information applicable to a particular bypass line managed by this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpUpsBypassLineEntry  

tlpUpsBypassLineIndex 1.3.6.1.4.1.850.1.1.3.1.3.4.2.1.1
The bypass line identifier.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsBypassLineVoltage 1.3.6.1.4.1.850.1.1.3.1.3.4.2.1.2
The present bypass voltage.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsBypassLineCurrent 1.3.6.1.4.1.850.1.1.3.1.3.4.2.1.3
The present bypass current.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsBypassLinePower 1.3.6.1.4.1.850.1.1.3.1.3.4.2.1.4
The present true power conveyed by the bypass.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsOutletTable 1.3.6.1.4.1.850.1.1.3.1.3.5.1
The details of each ups outlet in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpUpsOutletEntry

tlpUpsOutletEntry 1.3.6.1.4.1.850.1.1.3.1.3.5.1.1
An entry containing information applicable to a particular outlet managed by this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpUpsOutletEntry  

tlpUpsOutletIndex 1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.1
The table row index for the ups outlet.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsOutletName 1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.2
A user-definable string identifying the name of the outlet.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

tlpUpsOutletDescription 1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.3
A user-definable string identifying the device(s) connected to the given outlet.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

tlpUpsOutletState 1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.4
The current state of the outlet.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), off(1), on(2)  

tlpUpsOutletControllable 1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.5
Denotes whether this outlet is controllable.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpUpsOutletCommand 1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.6
Reading this value will always return 0. Setting this value to turnOff(1) will turn off the outlet. Setting this value to turnOn(2) will turn on the outlet. Setting this value to cycle(3) will turn the outlet off, then turn it back on.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER idle(0), turnOff(1), turnOn(2), cycle(3)  

tlpUpsOutletVoltage 1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.7
The magnitude of the present output voltage for a given outlet. If the voltage measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle voltage measurements is denoted by tlpUpsSupportsOutletVoltage.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsOutletCurrent 1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.8
The present output current, in hundredths of amps, of a given outlet. If the current measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle current measurements is denoted by tlpUpsSupportsCurrentPower.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsOutletPower 1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.9
The output power of a given outlet. If the power measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle power measurements is denoted by tlpUpsSupportsCurrentPower.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsOutletRampAction 1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.10
The ramp action to take on a given outlet when powering on the device. If this receptacle is not controllable, as denoted by tlpUpsOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER remainOff(0), turnOnAfterDelay(1)  

tlpUpsOutletRampDelay 1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.11
The number of seconds to delay before powering on the given outlet. If this receptacle is not controllable, as denoted by tlpUpsOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tlpUpsOutletShedAction 1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.12
The shed action to take on a given outlet when powering off the device. If this receptacle is not controllable, as denoted by tlpUpsOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER remainOn(0), turnOffAfterDelay(1)  

tlpUpsOutletShedDelay 1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.13
The number of seconds to delay before powering off the given outlet. If this receptacle is not controllable, as denoted by tlpUpsOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tlpUpsOutletGroup 1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.14
The tlpUpsOutletGroupIndex group index of the respective group to which the given outlet is assigned, or zero (0) if the given outlet is not grouped.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tlpUpsOutletGroupTable 1.3.6.1.4.1.850.1.1.3.1.3.5.2
The receptacle grouping details of each ups in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpUpsIdentNumOutletGroups per each device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpUpsOutletGroupEntry

tlpUpsOutletGroupEntry 1.3.6.1.4.1.850.1.1.3.1.3.5.2.1
An entry containing information applicable to a particular outlet group managed by this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpUpsOutletGroupEntry  

tlpUpsOutletGroupIndex 1.3.6.1.4.1.850.1.1.3.1.3.5.2.1.1
The table row index for the ups outlet group.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsOutletGroupRowStatus 1.3.6.1.4.1.850.1.1.3.1.3.5.2.1.2
Row status for the tlpUpsOutletGroupTable
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

tlpUpsOutletGroupName 1.3.6.1.4.1.850.1.1.3.1.3.5.2.1.3
The name of this outlet group.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

tlpUpsOutletGroupDescription 1.3.6.1.4.1.850.1.1.3.1.3.5.2.1.4
A description for this outlet group.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

tlpUpsOutletGroupState 1.3.6.1.4.1.850.1.1.3.1.3.5.2.1.5
The current state of the outlet group. This value will report off(1) if all outlets in the group are off, on(2) if all outlets in the group are on, mixed(3) if some outlets in the group are off and others are on, or unknown(0) if the state of the outlets cannot be determined.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), off(1), on(2), mixed(3)  

tlpUpsOutletGroupCommand 1.3.6.1.4.1.850.1.1.3.1.3.5.2.1.6
Reading this value will always return 0. Setting this value to turnOff(1) will turn off every outlet associated with the group. Setting this value to turnOn(2) will turn on every outlet associated with the group. Setting this value to cycle(3) will turn off every outlet associated with the group, then turn each outlet back on.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER idle(0), turnOff(1), turnOn(2), cycle(3)  

tlpUpsWatchdogTable 1.3.6.1.4.1.850.1.1.3.1.3.6.1
The watchdog details of each ups in device table. This is a sparse dependent table, and will contain some subset of devices that are upss.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpUpsWatchdogEntry

tlpUpsWatchdogEntry 1.3.6.1.4.1.850.1.1.3.1.3.6.1.1
An entry containing watchdog details for a particular ups.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpUpsWatchdogEntry  

tlpUpsWatchdogSupported 1.3.6.1.4.1.850.1.1.3.1.3.6.1.1.1
Indicates whether or not this ups supports a watchdog reboot.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpUpsWatchdogSecsBeforeReboot 1.3.6.1.4.1.850.1.1.3.1.3.6.1.1.2
The maximum number of seconds that can expire between polls that the engine makes to the ups for data. If this time runs out, then the ups will cycle its outputs. Set this to zero to turns disable this feature.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpUpsFanTable 1.3.6.1.4.1.850.1.1.3.1.3.7.1
The fan speed of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumFans.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpUpsFanEntry

tlpUpsFanEntry 1.3.6.1.4.1.850.1.1.3.1.3.7.1.1
An entry containing information applicable to a particular fan managed by this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpUpsFanEntry  

tlpUpsFanIndex 1.3.6.1.4.1.850.1.1.3.1.3.7.1.1.1
The table row index for the ups fan speed.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsFanSpeed 1.3.6.1.4.1.850.1.1.3.1.3.7.1.1.2
The fan speed in rotations per minute.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpUpsControlTable 1.3.6.1.4.1.850.1.1.3.1.4.1
The actionable controls for each ups in device table. This is a sparse dependent table, and will contain some subset of devices that are upss.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpUpsControlEntry

tlpUpsControlEntry 1.3.6.1.4.1.850.1.1.3.1.4.1.1
An entry containing controls for a particular ups.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpUpsControlEntry  

tlpUpsControlSelfTest 1.3.6.1.4.1.850.1.1.3.1.4.1.1.1
Set to TRUE to initiate a self test on the ups.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

tlpUpsControlRamp 1.3.6.1.4.1.850.1.1.3.1.4.1.1.2
Set to TRUE to initiate the pre-designated ramp sequence on the ups.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

tlpUpsControlShed 1.3.6.1.4.1.850.1.1.3.1.4.1.1.3
Set to TRUE to initiate the pre-designated shed sequence on the ups.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

tlpUpsControlUpsOn 1.3.6.1.4.1.850.1.1.3.1.4.1.1.4
Set to TRUE to turn the ups on.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

tlpUpsControlUpsOff 1.3.6.1.4.1.850.1.1.3.1.4.1.1.5
Set to TRUE to turn the ups off.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

tlpUpsControlUpsReboot 1.3.6.1.4.1.850.1.1.3.1.4.1.1.6
Set to TRUE to reboot the ups.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

tlpUpsControlBypass 1.3.6.1.4.1.850.1.1.3.1.4.1.1.7
This switches the ups in and out of bypass mode. This value returns the current bypass mode: disable(0) if the ups is not in bypass mode, enable(1) if the ups is in bypass mode. Set to disable(0) to exit bypass mode, or enable(1) to enter bypass mode. If switching bypass mode is not supported, this value will return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

tlpUpsControlResetWattHours 1.3.6.1.4.1.850.1.1.3.1.4.1.1.8
Set to TRUE to reset the tlpUpsInputWattHours calculation algorithm.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

tlpUpsConfigTable 1.3.6.1.4.1.850.1.1.3.1.5.1
The configuration details of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpUpsConfigEntry

tlpUpsConfigEntry 1.3.6.1.4.1.850.1.1.3.1.5.1.1
An entry containing information applicable to all input lines per each ups managed by this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpUpsConfigEntry  

tlpUpsConfigInputVoltage 1.3.6.1.4.1.850.1.1.3.1.5.1.1.1
The nominal value of the input line voltage. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME. This value may not be writable on all models. If not writable, the value will be rejected and an appropriate error message will be returned.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpUpsConfigInputFrequency 1.3.6.1.4.1.850.1.1.3.1.5.1.1.2
The nominal input frequency. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpUpsConfigOutputVoltage 1.3.6.1.4.1.850.1.1.3.1.5.1.1.3
The nominal value of the output voltage. This value may not be supported on all models. If not supported, the agent reports ERROR_NO_SUCH_NAME. This value may not be writable on all models. If not writable, the value will be rejected and an appropriate error message will be returned.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpUpsConfigOutputFrequency 1.3.6.1.4.1.850.1.1.3.1.5.1.1.4
The nominal output frequency. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request will be rejected and the agent will respond with an appropriate error message.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpUpsConfigAudibleStatus 1.3.6.1.4.1.850.1.1.3.1.5.1.1.5
The requested state of the audible alarm. When in the disabled state, the audible alarm should never sound. The enabled state is self- describing. Setting this object to muted(3) when the audible alarm is sounding shall temporarily silence the alarm. It will remain muted until it would normally stop sounding and the value returned for read operations during this period shall equal muted(3). At the end of this period, the value shall revert to enabled(2). Writes of the value muted(3) when the audible alarm is not sounding shall be accepted but otherwise shall have no effect.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), muted(3)  

tlpUpsConfigAutoBatteryTest 1.3.6.1.4.1.850.1.1.3.1.5.1.1.6
When disabled(0), the ups will not perform an automatic battery selftest. When set to another value, the ups will perform an automatic selftest in the approximate period defined by each respective enumerated value. This feature is generally not recommended.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), biweekly(1), monthly(2), quarterly(3), semiannually(4)  

tlpUpsConfigAutoRestartAfterShutdown 1.3.6.1.4.1.850.1.1.3.1.5.1.1.7
When enabled(1), the ups should autorestart after a shutdown from battery mode if valid AC is applied. When disabled(0), the ups should not autorestart when AC is restored and instead power up into standby mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

tlpUpsConfigAutoRampOnTransition 1.3.6.1.4.1.850.1.1.3.1.5.1.1.8
When enabled(1), the ups should perform its preconfigured ramp sequence when valid AC is restored while in battery mode. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

tlpUpsConfigAutoShedOnTransition 1.3.6.1.4.1.850.1.1.3.1.5.1.1.9
When enabled(1), the ups should perform its preconfigured shed sequence when valid AC is lost causing the ups to enter battery mode. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

tlpUpsConfigBypassLowerLimitPercent 1.3.6.1.4.1.850.1.1.3.1.5.1.1.10
The lowest AC input voltage allowed to be output to the load while in bypass mode. This setting is expressed as a percentage from nominal voltage. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER -20..-5  

tlpUpsConfigBypassUpperLimitPercent 1.3.6.1.4.1.850.1.1.3.1.5.1.1.11
The highest AC input voltage allowed to be output to the load while in bypass mode. This setting is expressed as a percentage from nominal voltage. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 5..20  

tlpUpsConfigBypassLowerLimitVoltage 1.3.6.1.4.1.850.1.1.3.1.5.1.1.12
The lowest AC input voltage allowed to be output to the load while in bypass mode. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpUpsConfigBypassUpperLimitVoltage 1.3.6.1.4.1.850.1.1.3.1.5.1.1.13
The highest AC input voltage allowed to be output to the load while in bypass mode. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpUpsConfigColdStart 1.3.6.1.4.1.850.1.1.3.1.5.1.1.14
This option enables or disables the ability to turn the ups on without AC supplied. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

tlpUpsConfigEconomicMode 1.3.6.1.4.1.850.1.1.3.1.5.1.1.15
The configurable economic mode options for the ups. The online(0) mode is the default configuration of most upss, which is synonymous as having the economic mode disabled. The economy(1) mode is the typical configuration to run in economy mode, which is synonymous as having the economic mode enabled. Constant50Hz(2) is a power strategy, which fixes the output frequency at 50Hz. Constant60Hz(3) is a power strategy, which fixes the output frequency at 60Hz. ConstantAuto(4) regulates the output frequency at nominal input frequency. AutoAdaptive(5) mode will cause the ups to automatically switch between online(0), maximum quality, and economy(1), maximum efficiency, to improve efficiency during stable utility periods and improve output regulation during unstable utility periods. Not all values are supported by all upss. Most upss, if supportive of economic mode, only supports online(0) and economy(1). If the ups does not support economic mode, then this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER online(0), economy(1), constant50Hz(2), constant60Hz(3), constantAuto(4), autoAdaptive(5)  

tlpUpsConfigFaultAction 1.3.6.1.4.1.850.1.1.3.1.5.1.1.16
Determines the action to take if the output needs to be shut down due to a fault condition, limited by the type of fault incurred. When configured for bypass(0), the ups will go to bypass on a fault condition. When configured for standby(1), the ups will go to standby mode on a fault condition. Either configuration will be valid as long as AC input is within normal line voltage and frequency limits when the fault condition occurs. If the line is outside these limits, the ups will turn off. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER bypass(0), standby(1)  

tlpUpsConfigOffMode 1.3.6.1.4.1.850.1.1.3.1.5.1.1.17
This option governs what mode the ups should go into when AC input is available, but the load is either off or not battery backed up. If this setting is configured for bypass(1), the intention is that any time the ups would normally go into standby mode, it would instead go into bypass mode. Note that this setting does not dictate the mode for fault conditions, which is governed by tlpUpsConfigFaultAction. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER standby(0), bypass(1)  

tlpUpsConfigLineSensitivity 1.3.6.1.4.1.850.1.1.3.1.5.1.1.18
Adjusts the AC line voltage sensitivity setting. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normal(0), reduced(1), fullyReduced(2)  

tlpUpsConfigAutoRestartTable 1.3.6.1.4.1.850.1.1.3.1.5.2
The configurable automatic restart options of each ups in device table. This is a sparse dependent table, and will contain some subset of devices that are upss. Not all options are available on all upss.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpUpsConfigAutoRestartEntry

tlpUpsConfigAutoRestartEntry 1.3.6.1.4.1.850.1.1.3.1.5.2.1
An entry containing configurable automatic restart options for a particular ups.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpUpsConfigAutoRestartEntry  

tlpUpsConfigAutoRestartInverterShutdown 1.3.6.1.4.1.850.1.1.3.1.5.2.1.1
If enabled(1) and the ups is turned off from invert mode (via user interaction), if line becomes valid, the ups will automatically go to line mode. If disabled(0), the ups will turn back on and go to standby mode instead.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

tlpUpsConfigAutoRestartDelayedWakeup 1.3.6.1.4.1.850.1.1.3.1.5.2.1.2
If enabled(1) and power fails during a DelayBeforeStartup and line remains invalid after the timeout expires, the ups will be set to turn back on automatically. If disabled(0), the ups will turn back on and go to standby mode instead.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

tlpUpsConfigAutoRestartLowVoltageCutoff 1.3.6.1.4.1.850.1.1.3.1.5.2.1.3
If enabled(1) and the ups is turned off from invert mode (via low voltage cutoff), if line becomes valid, the ups will automatically go to line mode. If disabled(0), the ups will turn back on and go to standby mode instead.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

tlpUpsConfigAutoRestartOverLoad 1.3.6.1.4.1.850.1.1.3.1.5.2.1.4
If enabled(1) and the ups is turned off from invert mode (via overload), if line becomes valid, the ups will automatically go to line mode. If disabled(0), the ups will turn back on and go to standby mode instead.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

tlpUpsConfigAutoRestartOverTemperature 1.3.6.1.4.1.850.1.1.3.1.5.2.1.5
If enabled(1) and the ups is turned off from invert mode (via over temperature), if line becomes valid, the ups will automatically go to line mode. If disabled(0), the ups will turn back on and go to standby mode instead.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

tlpUpsConfigThresholdTable 1.3.6.1.4.1.850.1.1.3.1.5.3
The configurable threshold options of each ups in device table. This is a sparse dependent table, and will contain some subset of devices that are upss. Not all options are available on all upss.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpUpsConfigThresholdEntry

tlpUpsConfigThresholdEntry 1.3.6.1.4.1.850.1.1.3.1.5.3.1
An entry containing configurable threshold options for a particular ups.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpUpsConfigThresholdEntry  

tlpUpsConfigBatteryAgeThreshold 1.3.6.1.4.1.850.1.1.3.1.5.3.1.1
The number of months for a battery to be in service. The battery age alarm, tlpUpsAlarmBatteryAgeAboveThreshold, is triggered when the current date exceeds tlpUpsBatteryPackIdentInstallDate by tlpUpsConfigBatteryAgeThreshold months.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpUpsConfigLowBatteryThreshold 1.3.6.1.4.1.850.1.1.3.1.5.3.1.2
This value denotes the percentage of battery capacity remaining warning level. The low battery alarm, tlpUpsAlarmLowBattery, is triggered when tlpUpsEstimatedChargeRemaining drops below this value.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 5..95  

tlpUpsConfigLowBatteryTime 1.3.6.1.4.1.850.1.1.3.1.5.3.1.3
The value in seconds of tlpUpsEstimatedMinutesRemaining at which a lowBattery condition is declared. For agents which support only discrete (discontinuous) values, then the agent shall round up to the next supported value. If the requested value is larger than the largest supported value, then the largest supported value shall be selected.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpUpsConfigOverLoadThreshold 1.3.6.1.4.1.850.1.1.3.1.5.3.1.4
This value denotes the percentage of load at which the overload condition occurs. The overload alarm, tlpUpsAlarmOutputOverload, is triggered when the percentage of output load exceeds this value.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 5..105  

tlpPduIdentNumPdu 1.3.6.1.4.1.850.1.1.3.2.1.1
The number of pdu devices that this agent is currently managing.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduIdentTable 1.3.6.1.4.1.850.1.1.3.2.1.2
The identity details of each pdu in device table. This is a sparse dependent table, and will contain some subset of devices that are pdus.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpPduIdentEntry

tlpPduIdentEntry 1.3.6.1.4.1.850.1.1.3.2.1.2.1
An entry containing details for a particular pdu.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpPduIdentEntry  

tlpPduIdentNumInputs 1.3.6.1.4.1.850.1.1.3.2.1.2.1.1
The number of input lines supported by the pdu.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduIdentNumOutputs 1.3.6.1.4.1.850.1.1.3.2.1.2.1.2
The number of output lines supported by the pdu.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduIdentNumPhases 1.3.6.1.4.1.850.1.1.3.2.1.2.1.3
The number of phases supported by the pdu.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduIdentNumOutlets 1.3.6.1.4.1.850.1.1.3.2.1.2.1.4
The number of receptacles supported by the pdu.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduIdentNumOutletGroups 1.3.6.1.4.1.850.1.1.3.2.1.2.1.5
The number of receptacle groups supported by the pdu.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduIdentNumCircuits 1.3.6.1.4.1.850.1.1.3.2.1.2.1.6
The number of circuits supported by the pdu.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduIdentNumBreakers 1.3.6.1.4.1.850.1.1.3.2.1.2.1.7
The number of monitored bank breakers supported by the pdu. If the pdu has breakers that are not monitored by the device, the value of zero(0) will be returned.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduIdentNumHeatsinks 1.3.6.1.4.1.850.1.1.3.2.1.2.1.8
The number of heatsink thermistors supported by the pdu.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduSupportsTable 1.3.6.1.4.1.850.1.1.3.2.1.3
The supported details of each pdu in device table. This is a sparse dependent table, and will contain some subset of devices that are pdus.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpPduSupportsEntry

tlpPduSupportsEntry 1.3.6.1.4.1.850.1.1.3.2.1.3.1
An entry containing supported details for a particular pdu.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpPduSupportsEntry  

tlpPduSupportsEnergywise 1.3.6.1.4.1.850.1.1.3.2.1.3.1.1
Indicates whether the pdu supports Cisco EnergyWise.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpPduSupportsRampShed 1.3.6.1.4.1.850.1.1.3.2.1.3.1.2
Indicates whether the pdu supports ramping and shedding.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpPduSupportsOutletGroup 1.3.6.1.4.1.850.1.1.3.2.1.3.1.3
Indicates whether the pdu supports outlet groups.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpPduSupportsOutletCurrentPower 1.3.6.1.4.1.850.1.1.3.2.1.3.1.4
Indicates whether the pdu reports individual receptacle current and power measurements. Devices that do not support individual receptacle measurements will always return ERROR_NO_SUCH_NAME for tlpPduOutletCurrent and tlpPduOutletPower.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpPduSupportsOutletVoltage 1.3.6.1.4.1.850.1.1.3.2.1.3.1.5
Indicates whether the pdu reports individual receptacle voltage measurements. Devices that do not support individual receptacle measurements will always return ERROR_NO_SUCH_NAME for tlpPduOutletVoltage.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpPduDisplayTable 1.3.6.1.4.1.850.1.1.3.2.1.4
The display details of each pdu in device table. This is a sparse dependent table, and will contain some subset of devices that are pdus.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpPduDisplayEntry

tlpPduDisplayEntry 1.3.6.1.4.1.850.1.1.3.2.1.4.1
An entry containing display details for a particular pdu.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpPduDisplayEntry  

tlpPduDisplayScheme 1.3.6.1.4.1.850.1.1.3.2.1.4.1.1
Indicates the display scheme of the LED display. The value schemeReverse(0) indicates the tricolor LED indicator uses an alternate pattern. The value schemeNormal(1) indicates the LED indicator uses the standard pattern. This value may not be supported on all models. If not supported, the value will always return schemeNormal(1).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER schemeReverse(0), schemeNormal(1)  

tlpPduDisplayOrientation 1.3.6.1.4.1.850.1.1.3.2.1.4.1.2
Indicates the physical orientation of the LED display. The value displayNormal(0) indicates the display is right-side-up (normal). The value displayReverse(1) indicates the display is upside-down. This value may not be supported on all models. If not supported, the value will always return displayNormal(0).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER displayNormal(0), displayReverse(1)  

tlpPduDisplayAutoScroll 1.3.6.1.4.1.850.1.1.3.2.1.4.1.3
Indicates whether the LED display automatically scrolls through displaying status values.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER scrollDisabled(0), scrollEnabled(1)  

tlpPduDisplayIntensity 1.3.6.1.4.1.850.1.1.3.2.1.4.1.4
Indicates the intensity, as a percentage, of the LED display. The value intensity100(4) indicates the display is at 100% intensity. The other values indicate the display is at a lesser intensity based upon the respective percentage denoted.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER intensity25(1), intensity50(2), intensity75(3), intensity100(4)  

tlpPduDisplayUnits 1.3.6.1.4.1.850.1.1.3.2.1.4.1.5
Indicates the units of measurement displayed on the LED display. The value normal(0) indicates that a temperature value, for example, is displayed in degrees Fahrenheit. The value metric(1) indicates a temperature value is displayed in degrees Celsius.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normal(0), metric(1)  

tlpPduDeviceTable 1.3.6.1.4.1.850.1.1.3.2.2.1
The device details of each pdu in device table. This is a sparse dependent table, and will contain some subset of devices that are pdus.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpPduDeviceEntry

tlpPduDeviceEntry 1.3.6.1.4.1.850.1.1.3.2.2.1.1
An entry containing device details for a particular pdu.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpPduDeviceEntry  

tlpPduDeviceMainLoadState 1.3.6.1.4.1.850.1.1.3.2.2.1.1.1
The current state of the main output of the device.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), off(1), on(2)  

tlpPduDeviceMainLoadControllable 1.3.6.1.4.1.850.1.1.3.2.2.1.1.2
Indicates whether or not the main output is controllable, and whether the ups can be turned off and on.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpPduDeviceMainLoadCommand 1.3.6.1.4.1.850.1.1.3.2.2.1.1.3
Reading this value will always return 0. Setting this value to turnOff(1) will turn off the main output of the ups. Setting this value to turnOn(2) will turn on the main output of the ups. Setting this value to cycle(3) will turn off the main output, then turn it back on.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER idle(0), turnOff(1), turnOn(2), cycle(3)  

tlpPduDevicePowerOnDelay 1.3.6.1.4.1.850.1.1.3.2.2.1.1.4
The configurable delay value, which sets the amount of additional time a given device will wait before it connects to a valid AC source. By default the delay value is set to 0. For devices with multiple AC input sources, this delay only applies to the primary input source.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tlpPduDeviceTotalInputPowerRating 1.3.6.1.4.1.850.1.1.3.2.2.1.1.5
The total input power rating of all phases on the device. This value may not be supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpPduDeviceTemperatureC 1.3.6.1.4.1.850.1.1.3.2.2.1.1.6
The ambient temperature at or near the PDU casing. Temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpPduDeviceTemperatureF 1.3.6.1.4.1.850.1.1.3.2.2.1.1.7
The ambient temperature at or near the PDU casing. Temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpPduDevicePhaseImbalance 1.3.6.1.4.1.850.1.1.3.2.2.1.1.8
The percentage of imbalance of the three phases. This value is in the range from 0% imbalance to 100% imbalance. The lower the value, the better balanced the phases are. If all load is on a single phase, the imbalance is defined as 100%.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..200  

tlpPduDeviceOutputPowerTotal 1.3.6.1.4.1.850.1.1.3.2.2.1.1.9
The AC output total power for all circuits.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduDeviceAggregatePowerFactor 1.3.6.1.4.1.850.1.1.3.2.2.1.1.10
The aggregate power factor of all phases.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduDeviceOutputCurrentPrecision 1.3.6.1.4.1.850.1.1.3.2.2.1.1.11
Output current is reported by tlpPduOutputCurrent, tlpPduOutputCurrentMin and tlpPduOutputCurrentMax. These values are all reported in hundredths(0.01A), which accommodates all models; however, on any given device the actual precision may vary. All current values must be divided by 100 to obtain the actual value. For example, if tlpPduOutputCurrent reports 500, then the actual output current is 5.00. This tlpPduDeviceOutputCurrentPrecision defines the actual resolution of that value: wholeNumber(0) is 5, tenths(1) is 5.0 and hundredths(2) is 5.00.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER wholeNumber(0), tenths(1), hundredths(2)  

tlpPduInputTable 1.3.6.1.4.1.850.1.1.3.2.3.1.1
The input details of each pdu in device table. This is a sparse dependent table, and will contain the number of entries based upon the number of pdus managed by the agent as reported by tlpPduIdentNumPdus.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpPduInputEntry

tlpPduInputEntry 1.3.6.1.4.1.850.1.1.3.2.3.1.1.1
An entry containing information applicable to a particular pdu managed by this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpPduInputEntry  

tlpPduInputNominalVoltage 1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.1
The nominal value of the input line voltage. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduInputNominalVoltagePhaseToPhase 1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.2
The nominal value of the input line voltage as measured from phase to phase. This value may not be supported on all models. If not supported, this value will always return zero.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduInputNominalVoltagePhaseToNeutral 1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.3
The nominal value of the input line voltage as measured from phase to neutral. This value may not be supported on all models. If not supported, this value will always return zero.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduInputLowTransferVoltage 1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.4
The minimum line voltage allowed before the unit disconnects the AC input connection. This value may not be writable on all models. If not writable, the value will be rejected and an appropriate error message will be returned. When supported, the minimum and maximum values allowed are dictated by tlpPduInputLowTransferVoltageLowerBound and tlpPduInputLowTransferVoltageUpperBound respectively.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduInputLowTransferVoltageLowerBound 1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.5
The lower boundary value of tlpPduInputLowTransferVoltage as dictated by the hardware of the unit.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduInputLowTransferVoltageUpperBound 1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.6
The upper boundary value of tlpPduInputLowTransferVoltage as dictated by the hardware of the unit.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduInputHighTransferVoltage 1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.7
The maximum line voltage allowed before the unit disconnects the AC input connection. This value may not be writable on all models. If not writable, the value will be rejected and an appropriate error message will be returned. When supported, the minimum and maximum values allowed are dictated by tlpPduInputHighTransferVoltageLowerBound and tlpPduInputHighTransferVoltageUpperBound respectively.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduInputHighTransferVoltageLowerBound 1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.8
The lower boundary value of tlpPduInputHighTransferVoltage as dictated by the hardware of the unit.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduInputHighTransferVoltageUpperBound 1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.9
The upper boundary value of tlpPduInputHighTransferVoltage as dictated by the hardware of the unit.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduInputCurrentLimit 1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.10
The capacity of each phase conductor in the pdu limited by the AC input cord or any other potential limiting factors unique to a given unit.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduInputPhaseTable 1.3.6.1.4.1.850.1.1.3.2.3.1.2
The input phase details of each pdu in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpPduIdentNumInputs and tlpPduIdentNumPhases per each device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpPduInputPhaseEntry

tlpPduInputPhaseEntry 1.3.6.1.4.1.850.1.1.3.2.3.1.2.1
An entry containing information applicable to a particular input phase managed by this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpPduInputPhaseEntry  

tlpPduInputPhaseIndex 1.3.6.1.4.1.850.1.1.3.2.3.1.2.1.1
The table row index for the pdu phase.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduInputPhasePhaseType 1.3.6.1.4.1.850.1.1.3.2.3.1.2.1.2
Denotes whether measurements are phase to neutral(0) or phase to phase(1).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER phaseToNeutral(0), phaseToPhase(1)  

tlpPduInputPhaseFrequency 1.3.6.1.4.1.850.1.1.3.2.3.1.2.1.3
The present input frequency for a given phase.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduInputPhaseVoltage 1.3.6.1.4.1.850.1.1.3.2.3.1.2.1.4
The magnitude of the present input voltage for a given phase.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduInputPhaseVoltageMin 1.3.6.1.4.1.850.1.1.3.2.3.1.2.1.5
The minimum input voltage value since the last reset of this value for a given phase. If any value is written to either tlpPduInputVoltageMin or tlpPduInputVoltageMax, both will be reset to their appropriate minimum and maximum values.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpPduInputPhaseVoltageMax 1.3.6.1.4.1.850.1.1.3.2.3.1.2.1.6
The maximum input voltage value since the last reset of this value for a given phase. If any value is written to either tlpPduInputVoltageMin or tlpPduInputVoltageMax, both will be reset to their appropriate minimum and maximum values.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpPduInputPhaseCurrent 1.3.6.1.4.1.850.1.1.3.2.3.1.2.1.7
The magnitude of the present input current for a given phase.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduOutputTable 1.3.6.1.4.1.850.1.1.3.2.3.2.1
The output details of each pdu in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpPduIdentNumOutputs per each device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpPduOutputEntry

tlpPduOutputEntry 1.3.6.1.4.1.850.1.1.3.2.3.2.1.1
An entry containing output information applicable to a particular phase managed by this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpPduOutputEntry  

tlpPduOutputIndex 1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.1
The table row index for the pdu phase.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduOutputPhase 1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.2
Indicates the phase associated with the output line.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER phase1(1), phase2(2), phase3(3)  

tlpPduOutputPhaseType 1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.3
Denotes whether measurements are phase to neutral(0) or phase to phase(1).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER phaseToNeutral(0), phaseToPhase(1)  

tlpPduOutputVoltage 1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.4
The magnitude of the present output voltage for a given output line.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduOutputCurrent 1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.5
The output current, in hundredths of amps, for a given phase. The actual precision of this value, whether a whole number, tenths or hundredths, is returned by tlpPduDeviceOutputCurrentPrecision.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduOutputCurrentMin 1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.6
The minimum current, in hundredths of amps, observed for a given phase since last reset. The actual precision of this value, whether a whole number, tenths or hundredths, is returned by tlpPduDeviceOutputCurrentPrecision.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduOutputCurrentMax 1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.7
The maximum current, in hundredths of amps, observed for a given phase since last reset. The actual precision of this value, whether a whole number, tenths or hundredths, is returned by tlpPduDeviceOutputCurrentPrecision.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduOutputActivePower 1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.8
The output power for a given phase.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduOutputPowerFactor 1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.9
The output power factor, in hundredths of a percent, for a given phase.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduOutputSource 1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.10
The present source of output power. The enumeration none(0) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), normal(1)  

tlpPduOutputFrequency 1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.11
The present output frequency. If not supported, the agent reports ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduOutputCalculatedPowerKVA 1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.12
The calculated amount of apparent power being used.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduOutputCalculatedPowerKW 1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.13
The calculated amount of active power being used.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduOutputCalculated24hrEnergy 1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.14
Estimated 24 hour power consumption using present value of tlpPduOutputCalculatedPowerKW.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduOutletTable 1.3.6.1.4.1.850.1.1.3.2.3.3.1
The receptacle status details of each pdu in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpPduIdentNumOutlets per each device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpPduOutletEntry

tlpPduOutletEntry 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1
An entry containing information applicable to a particular outlet managed by this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpPduOutletEntry  

tlpPduOutletIndex 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.1
The table row index for the pdu outlet.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduOutletName 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.2
A user-definable string identifying the name of the outlet.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

tlpPduOutletDescription 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.3
A user-definable string identifying the device(s) connected to the given outlet.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

tlpPduOutletState 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.4
The current state of the outlet.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), off(1), on(2)  

tlpPduOutletControllable 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.5
Denotes whether this outlet is controllable.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpPduOutletCommand 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.6
Reading this value will always return 0. Setting this value to turnOff(1) will turn off the outlet. Setting this value to turnOn(2) will turn on the outlet. Setting this value to cycle(3) will turn the outlet off, then turn it back on.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER idle(0), turnOff(1), turnOn(2), cycle(3)  

tlpPduOutletVoltage 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.7
The magnitude of the present output voltage for a given outlet. If the voltage measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle voltage measurements is denoted by tlpPduSupportsOutletVoltage.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduOutletCurrent 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.8
The present output current, in hundredths of amps, of a given outlet. If the current measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle current measurements is denoted by tlpPduSupportsCurrentPower.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduOutletPower 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.9
The output power of a given outlet. If the power measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle power measurements is denoted by tlpPduSupportsCurrentPower.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduOutletRampAction 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.10
The ramp action to take on a given outlet when powering on the device. If this receptacle is not controllable, as denoted by tlpPduOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER remainOff(0), turnOnAfterDelay(1)  

tlpPduOutletRampDelay 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.11
The number of seconds to delay before powering on the given outlet. If this receptacle is not controllable, as denoted by tlpPduOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tlpPduOutletShedAction 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.12
The shed action to take on a given outlet when powering off the device. If this receptacle is not controllable, as denoted by tlpPduOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER remainOn(0), turnOffAfterDelay(1)  

tlpPduOutletShedDelay 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.13
The number of seconds to delay before powering off the given outlet. If this receptacle is not controllable, as denoted by tlpPduOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tlpPduOutletGroup 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.14
The tlpPduOutletGroupIndex group index of the respective group to which the given outlet is assigned, or zero (0) if the given outlet is not grouped.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tlpPduOutletBank 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.15
Indicates on which bank the given outlet is located.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpPduOutletCircuit 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.16
Indicates on which circuit the given outlet is wired.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpPduOutletPhase 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.17
Indicates on which phase or phases the given outlet is associated. For single phase devices, this object will always return phase1(1). For 3-phase devices with outlets wired to a single phase, this object will return phase1(1), phase2(2) or phase3(3). For 3-phase devices with outlets wired to two phases, this object will return phase1-2(4) for phases 1 and 2, phase2-3(5) for phases 2 and 3, and phase3-1(6) for phases 3 and 1. Devices that do not report phase connections will return unknown(0).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), phase1(1), phase2(2), phase3(3), phase1-2(4), phase2-3(5), phase3-1(6)  

tlpPduOutletGroupTable 1.3.6.1.4.1.850.1.1.3.2.3.3.2
The receptacle grouping details of each pdu in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpPduIdentNumOutletGroups per each device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpPduOutletGroupEntry

tlpPduOutletGroupEntry 1.3.6.1.4.1.850.1.1.3.2.3.3.2.1
An entry containing information applicable to a particular outlet group managed by this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpPduOutletGroupEntry  

tlpPduOutletGroupIndex 1.3.6.1.4.1.850.1.1.3.2.3.3.2.1.1
The table row index for the pdu outlet group.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduOutletGroupRowStatus 1.3.6.1.4.1.850.1.1.3.2.3.3.2.1.2
Row status for the tlpPduOutletGroupTable
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

tlpPduOutletGroupName 1.3.6.1.4.1.850.1.1.3.2.3.3.2.1.3
The name of this outlet group.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

tlpPduOutletGroupDescription 1.3.6.1.4.1.850.1.1.3.2.3.3.2.1.4
A description for this outlet group.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

tlpPduOutletGroupState 1.3.6.1.4.1.850.1.1.3.2.3.3.2.1.5
The current state of the outlet group. This value will report off(1) if all outlets in the group are off, on(2) if all outlets in the group are on, mixed(3) if some outlets in the group are off and others are on, or unknown(0) if the state of the outlets cannot be determined.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), off(1), on(2), mixed(3)  

tlpPduOutletGroupCommand 1.3.6.1.4.1.850.1.1.3.2.3.3.2.1.6
Reading this value will always return 0. Setting this value to turnOff(1) will turn off every outlet associated with the group. Setting this value to turnOn(2) will turn on every outlet associated with the group. Setting this value to cycle(3) will turn off every outlet associated with the group, then turn each outlet back on.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER turnOff(1), turnOn(2), cycle(3)  

tlpPduCircuitTable 1.3.6.1.4.1.850.1.1.3.2.3.4.1
A list of pdu circuit table entries. The number of entries is given by the value of tlpPduIdentNumCircuits.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpPduCircuitEntry

tlpPduCircuitEntry 1.3.6.1.4.1.850.1.1.3.2.3.4.1.1
An entry containing information applicable to a particular circuit managed by this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpPduCircuitEntry  

tlpPduCircuitIndex 1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.1
The table row index for the pdu circuit.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduCircuitPhase 1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.2
Indicates on which phase or phases the given circuit is wired. For single phase devices, this object will always return phase1(1). For 3-phase devices with outlets wired to a single phase, this object will return phase1(1), phase2(2) or phase3(3). For 3-phase devices with outlets wired to two phases, this object will return phase1-2(4) for phases 1 and 2, phase2-3(5) for phases 2 and 3, and phase3-1(6) for phases 3 and 1. Devices that do not report phase connections will return unknown(0).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), phase1(1), phase2(2), phase3(3), phase1-2(4), phase2-3(5), phase3-1(6)  

tlpPduCircuitInputVoltage 1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.3
The input voltage for a circuit.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpPduCircuitTotalCurrent 1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.4
The total current, in hundredths of amps, for all receptacles in a given circuit.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpPduCircuitCurrentLimit 1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.5
The current capacity, in hundredths of amps, of a circuit in the system limited by the circuit breaker or wiring used in a given unit.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpPduCircuitCurrentMin 1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.6
The minimum total current, in hundredths of amps, for all receptacles in a given circuit since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpPduCircuitCurrentMax 1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.7
The maximum total current, in hundredths of amps, for all receptacles in a given circuit since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpPduCircuitTotalPower 1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.8
The total power for all receptacles in a given circuit.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpPduCircuitPowerFactor 1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.9
The power factor for all receptacles in a given circuit.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..200  

tlpPduCircuitUtilization 1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.10
The percentage of utilization of a given circuit. This is typically a calculation of tlpPduCircuitTotalCurrent / tlpPduCircuitCurrentLimit.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduBreakerTable 1.3.6.1.4.1.850.1.1.3.2.3.5.1
A list of pdu bank breaker table entries. The number of entries is given by the value of tlpPduIdentNumBreakers.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpPduBreakerEntry

tlpPduBreakerEntry 1.3.6.1.4.1.850.1.1.3.2.3.5.1.1
An entry containing information applicable to a particular bank breaker managed by this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpPduBreakerEntry  

tlpPduBreakerIndex 1.3.6.1.4.1.850.1.1.3.2.3.5.1.1.1
The table row index for the pdu bank breaker.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduBreakerStatus 1.3.6.1.4.1.850.1.1.3.2.3.5.1.1.2
Indicates whether the bank breaker is open(0), closed(1) or not installed(2).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER open(0), closed(1), notInstalled(2)  

tlpPduHeatsinkTable 1.3.6.1.4.1.850.1.1.3.2.3.6.1
A list of pdu heatsink thermistor table entries. The number of entries is given by the value of tlpPduIdentNumHeatsinks.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpPduHeatsinkEntry

tlpPduHeatsinkEntry 1.3.6.1.4.1.850.1.1.3.2.3.6.1.1
An entry containing information applicable to a particular heatsink thermistor managed by this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpPduHeatsinkEntry  

tlpPduHeatsinkIndex 1.3.6.1.4.1.850.1.1.3.2.3.6.1.1.1
The table row index for the pdu heatsink thermistor.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduHeatsinkStatus 1.3.6.1.4.1.850.1.1.3.2.3.6.1.1.2
Indicates whether the heatsink thermistor is available. The entry will return notAvailable(0) if a thermistor is either non-existent or disconnected, or available(1) when connected.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notAvailable(0), available(1)  

tlpPduHeatsinkTemperatureC 1.3.6.1.4.1.850.1.1.3.2.3.6.1.1.3
The temperature at the heatsink thermistor in tenths degrees Celsius. Heatsink temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpPduHeatsinkTemperatureF 1.3.6.1.4.1.850.1.1.3.2.3.6.1.1.4
The temperature at the heatsink thermistor in tenths degrees Fahrenheit. Heatsink temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpPduControlTable 1.3.6.1.4.1.850.1.1.3.2.4.1
The actionable controls for each pdu in device table. This is a sparse dependent table, and will contain some subset of devices that are pdus.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpPduControlEntry

tlpPduControlEntry 1.3.6.1.4.1.850.1.1.3.2.4.1.1
An entry containing controls for a particular pdu.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpPduControlEntry  

tlpPduControlRamp 1.3.6.1.4.1.850.1.1.3.2.4.1.1.1
Set to TRUE to initiate the pre-designated ramp sequence on the pdu.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

tlpPduControlShed 1.3.6.1.4.1.850.1.1.3.2.4.1.1.2
Set to TRUE to initiate the pre-designated shed sequence on the pdu.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

tlpPduControlPduOn 1.3.6.1.4.1.850.1.1.3.2.4.1.1.3
Set to TRUE to turn the pdu on.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

tlpPduControlPduOff 1.3.6.1.4.1.850.1.1.3.2.4.1.1.4
Set to TRUE to turn the pdu off.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

tlpPduControlPduReboot 1.3.6.1.4.1.850.1.1.3.2.4.1.1.5
Set to TRUE to reboot the pdu.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

tlpPduConfigTable 1.3.6.1.4.1.850.1.1.3.2.5.1
The configuration options of each pdu in device table. This is a sparse dependent table, and will contain some subset of devices that are pdus. Not all options are available on all pdus.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpPduConfigEntry

tlpPduConfigEntry 1.3.6.1.4.1.850.1.1.3.2.5.1.1
An entry containing configuration options for a particular pdu.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpPduConfigEntry  

tlpPduConfigInputVoltage 1.3.6.1.4.1.850.1.1.3.2.5.1.1.1
The nominal value of the input line voltage. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME. This value may not be writable on all models. If not writable, the value will be rejected and an appropriate error message will be returned.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpPduConfigPhaseThresholdTable 1.3.6.1.4.1.850.1.1.3.2.5.2
The configuration options of each pdu in device table. This is a sparse dependent table, and will contain some subset of devices that are pdus. Not all options are available on all pdus.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpPduConfigPhaseThresholdEntry

tlpPduConfigPhaseThresholdEntry 1.3.6.1.4.1.850.1.1.3.2.5.2.1
An entry containing threshold configuration options for a particular pdu.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpPduConfigPhaseThresholdEntry  

tlpPduPhaseIndex 1.3.6.1.4.1.850.1.1.3.2.5.2.1.1
The table row index for the pdu phase.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpPduConfigOutputCurrentThresholdTolerance 1.3.6.1.4.1.850.1.1.3.2.5.2.1.2
The threshold tolerance value used together with output current high/low threshold to evaluate output current high/low condition.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpPduConfigOutputCurrentHighThreshold 1.3.6.1.4.1.850.1.1.3.2.5.2.1.3
The value at which a output current high condition is declared.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpPduConfigOutputCurrentLowThreshold 1.3.6.1.4.1.850.1.1.3.2.5.2.1.4
The value at which a output current low condition is declared.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpEnvIdentNumEnvirosense 1.3.6.1.4.1.850.1.1.3.3.1.1
The number of envirosense devices that this agent is currently managing.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpEnvIdentTable 1.3.6.1.4.1.850.1.1.3.3.1.2
The identity details of each envirosense in device table. This is a sparse dependent table, and will contain some subset of devices that are envirosenses.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpEnvIdentEntry

tlpEnvIdentEntry 1.3.6.1.4.1.850.1.1.3.3.1.2.1
An entry containing details for a particular envirosense.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpEnvIdentEntry  

tlpEnvIdentTempSupported 1.3.6.1.4.1.850.1.1.3.3.1.2.1.1
Indicates whether or not temperature is supported.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpEnvIdentHumiditySupported 1.3.6.1.4.1.850.1.1.3.3.1.2.1.2
Indicates whether or not temperature is supported.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpEnvNumInputContacts 1.3.6.1.4.1.850.1.1.3.3.1.2.1.3
The number of input contacts supported by the envirosense.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpEnvNumOutputContacts 1.3.6.1.4.1.850.1.1.3.3.1.2.1.4
The number of output contacts supported by the envirosense.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpEnvTemperatureTable 1.3.6.1.4.1.850.1.1.3.3.3.1
The temperature details of each envirosense in device table. The number of entries is given by the value of tlpDevicesNumDevices.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpEnvTemperatureEntry

tlpEnvTemperatureEntry 1.3.6.1.4.1.850.1.1.3.3.3.1.1
An entry containing temperature details for a particular envirosense.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpEnvTemperatureEntry  

tlpEnvTemperatureC 1.3.6.1.4.1.850.1.1.3.3.3.1.1.1
The ambient temperature.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpEnvTemperatureF 1.3.6.1.4.1.850.1.1.3.3.3.1.1.2
The ambient temperature.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpEnvTemperatureInAlarm 1.3.6.1.4.1.850.1.1.3.3.3.1.1.3
Indicates whether or not temperature is in alarm.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpEnvHumidityTable 1.3.6.1.4.1.850.1.1.3.3.3.2
The humidity details of each envirosense in device table. The number of entries is given by the value of tlpDevicesNumDevices.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpEnvHumidityEntry

tlpEnvHumidityEntry 1.3.6.1.4.1.850.1.1.3.3.3.2.1
An entry containing humidity details for a particular envirosense.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpEnvHumidityEntry  

tlpEnvHumidityHumidity 1.3.6.1.4.1.850.1.1.3.3.3.2.1.1
The ambient humidity.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

tlpEnvHumidityInAlarm 1.3.6.1.4.1.850.1.1.3.3.3.2.1.2
Indicates whether or not humidity is in alarm.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpEnvInputContactTable 1.3.6.1.4.1.850.1.1.3.3.3.3
The input contact details of each envirosense in device table. The number of entries is given by the value of tlpDevicesNumDevices.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpEnvInputContactEntry

tlpEnvInputContactEntry 1.3.6.1.4.1.850.1.1.3.3.3.3.1
An entry containing input contact details for a particular envirosense.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpEnvInputContactEntry  

tlpEnvInputContactIndex 1.3.6.1.4.1.850.1.1.3.3.3.3.1.1
The table row index for the envirosense input contact details.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpEnvInputContactName 1.3.6.1.4.1.850.1.1.3.3.3.3.1.2
The name or description of the contact.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

tlpEnvInputContactNormalState 1.3.6.1.4.1.850.1.1.3.3.3.3.1.3
The normal operating position of the contact.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER open(0), closed(1)  

tlpEnvInputContactCurrentState 1.3.6.1.4.1.850.1.1.3.3.3.3.1.4
The current state of the contact.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER open(0), closed(1)  

tlpEnvInputContactInAlarm 1.3.6.1.4.1.850.1.1.3.3.3.3.1.5
Indicates whether or not the contact is in alarm.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpEnvOutputContactTable 1.3.6.1.4.1.850.1.1.3.3.3.4
The output contact details of each envirosense in device table. The number of entries is given by the value of tlpDevicesNumDevices.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpEnvOutputContactEntry

tlpEnvOutputContactEntry 1.3.6.1.4.1.850.1.1.3.3.3.4.1
An entry containing output contact details for a particular envirosense.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpEnvOutputContactEntry  

tlpEnvOutputContactIndex 1.3.6.1.4.1.850.1.1.3.3.3.4.1.1
The table row index for the envirosense output contact details.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpEnvOutputContactName 1.3.6.1.4.1.850.1.1.3.3.3.4.1.2
The name or description of the contact.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

tlpEnvOutputContactNormalState 1.3.6.1.4.1.850.1.1.3.3.3.4.1.3
The normal operating position of the contact.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER open(0), closed(1)  

tlpEnvOutputContactCurrentState 1.3.6.1.4.1.850.1.1.3.3.3.4.1.4
The current state of the contact.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER open(0), closed(1)  

tlpEnvOutputContactInAlarm 1.3.6.1.4.1.850.1.1.3.3.3.4.1.5
Indicates whether or not the contact is in alarm.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpEnvConfigTable 1.3.6.1.4.1.850.1.1.3.3.5.1
The configuration options of each envirosense in device table. This is a sparse dependent table, and will contain some subset of devices that are envirosenses. Not all options are available on all envirosenses.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpEnvConfigEntry

tlpEnvConfigEntry 1.3.6.1.4.1.850.1.1.3.3.5.1.1
An entry containing configuration options for a particular envirosenses.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpEnvConfigEntry  

tlpEnvTemperatureLowLimit 1.3.6.1.4.1.850.1.1.3.3.5.1.1.1
The lower alarm limit for ambient temperature.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tlpEnvTemperatureHighLimit 1.3.6.1.4.1.850.1.1.3.3.5.1.1.2
The upper alarm limit for ambient temperature.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tlpEnvHumidityLowLimit 1.3.6.1.4.1.850.1.1.3.3.5.1.1.3
The lower alarm limit for ambient humidity.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

tlpEnvHumidityHighLimit 1.3.6.1.4.1.850.1.1.3.3.5.1.1.4
The upper alarm limit for ambient humidity.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

tlpAtsIdentNumAts 1.3.6.1.4.1.850.1.1.3.4.1.1
The number of ats devices that this agent is currently managing.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsIdentTable 1.3.6.1.4.1.850.1.1.3.4.1.2
The identity details of each ats in device table. This is a sparse dependent table, and will contain some subset of devices that are atss.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpAtsIdentEntry

tlpAtsIdentEntry 1.3.6.1.4.1.850.1.1.3.4.1.2.1
An entry containing details for a particular ats.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpAtsIdentEntry  

tlpAtsIdentNumInputs 1.3.6.1.4.1.850.1.1.3.4.1.2.1.1
The number of inputs supported by the ats.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsIdentNumOutputs 1.3.6.1.4.1.850.1.1.3.4.1.2.1.2
The number of outputs supported by the ats.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsIdentNumPhases 1.3.6.1.4.1.850.1.1.3.4.1.2.1.3
The number of phases per input supported by the ats.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsIdentNumOutlets 1.3.6.1.4.1.850.1.1.3.4.1.2.1.4
The number of receptacles supported by the ats.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsIdentNumOutletGroups 1.3.6.1.4.1.850.1.1.3.4.1.2.1.5
The number of receptacle groups supported by the ats.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsIdentNumCircuits 1.3.6.1.4.1.850.1.1.3.4.1.2.1.6
The number of circuits supported by the ats.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsIdentNumBreakers 1.3.6.1.4.1.850.1.1.3.4.1.2.1.7
The number of monitored bank breakers supported by the ats. If the ats has breakers that are not monitored by the device, the value of zero(0) will be returned.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsIdentNumHeatsinks 1.3.6.1.4.1.850.1.1.3.4.1.2.1.8
The number of heatsink thermistors supported by the ats.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsSupportsTable 1.3.6.1.4.1.850.1.1.3.4.1.3
The supported details of each ats in device table. This is a sparse dependent table, and will contain some subset of devices that are atss.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpAtsSupportsEntry

tlpAtsSupportsEntry 1.3.6.1.4.1.850.1.1.3.4.1.3.1
An entry containing supported details for a particular ats.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpAtsSupportsEntry  

tlpAtsSupportsEnergywise 1.3.6.1.4.1.850.1.1.3.4.1.3.1.1
Indicates whether the ats supports Cisco EnergyWise.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpAtsSupportsRampShed 1.3.6.1.4.1.850.1.1.3.4.1.3.1.2
Indicates whether the ats supports ramping and shedding.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpAtsSupportsOutletGroup 1.3.6.1.4.1.850.1.1.3.4.1.3.1.3
Indicates whether the ats supports outlet groups.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpAtsSupportsOutletCurrentPower 1.3.6.1.4.1.850.1.1.3.4.1.3.1.4
Indicates whether the ats reports individual receptacle current and power measurements. Devices that do not support individual receptacle measurements will always return ERROR_NO_SUCH_NAME for tlpAtsOutletCurrent and tlpAtsOutletPower.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpAtsSupportsOutletVoltage 1.3.6.1.4.1.850.1.1.3.4.1.3.1.5
Indicates whether the ats reports individual receptacle voltage measurements. Devices that do not support individual receptacle measurements will always return ERROR_NO_SUCH_NAME for tlpAtsOutletVoltage.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpAtsDisplayTable 1.3.6.1.4.1.850.1.1.3.4.1.4
The display details of each ats in device table. This is a sparse dependent table, and will contain some subset of devices that are atss.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpAtsDisplayEntry

tlpAtsDisplayEntry 1.3.6.1.4.1.850.1.1.3.4.1.4.1
An entry containing display details for a particular ats.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpAtsDisplayEntry  

tlpAtsDisplayScheme 1.3.6.1.4.1.850.1.1.3.4.1.4.1.1
Indicates the display scheme of the LED display. The value schemeReverse(0) indicates the tricolor LED indicator uses an alternate pattern. The value schemeNormal(1) indicates the LED indicator uses the standard pattern. This value may not be supported on all models. If not supported, the value will always return schemeNormal(1).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER schemeReverse(0), schemeNormal(1)  

tlpAtsDisplayOrientation 1.3.6.1.4.1.850.1.1.3.4.1.4.1.2
Indicates the physical orientation of the LED display. The value displayNormal(0) indicates the display is right-side-up (normal). The value displayReverse(1) indicates the display is upside-down. This value may not be supported on all models. If not supported, the value will always return displayNormal(0).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER displayNormal(0), displayReverse(1)  

tlpAtsDisplayAutoScroll 1.3.6.1.4.1.850.1.1.3.4.1.4.1.3
Indicates whether the LED display automatically scrolls through displaying status values.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER scrollDisabled(0), scrollEnabled(1)  

tlpAtsDisplayIntensity 1.3.6.1.4.1.850.1.1.3.4.1.4.1.4
Indicates the intensity, as a percentage, of the LED display. The value intensity100(4) indicates the display is at 100% intensity. The other values indicate the display is at a lesser intensity based upon the respective percentage denoted.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER intensity25(1), intensity50(2), intensity75(3), intensity100(4)  

tlpAtsDisplayUnits 1.3.6.1.4.1.850.1.1.3.4.1.4.1.5
Indicates the units of measurement displayed on the LED display. The value normal(0) indicates that a temperature value, for example, is displayed in degrees Fahrenheit. The value metric(1) indicates a temperature value is displayed in degrees Celsius.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normal(0), metric(1)  

tlpAtsDeviceTable 1.3.6.1.4.1.850.1.1.3.4.2.1
The device details of each ats in device table. This is a sparse dependent table, and will contain some subset of devices that are atss.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpAtsDeviceEntry

tlpAtsDeviceEntry 1.3.6.1.4.1.850.1.1.3.4.2.1.1
An entry containing device details for a particular ats.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpAtsDeviceEntry  

tlpAtsDeviceMainLoadState 1.3.6.1.4.1.850.1.1.3.4.2.1.1.1
The current state of the main output of the device.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), off(1), on(2)  

tlpAtsDeviceMainLoadControllable 1.3.6.1.4.1.850.1.1.3.4.2.1.1.2
Indicates whether or not the main output is controllable, and whether the ups can be turned off and on.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpAtsDeviceMainLoadCommand 1.3.6.1.4.1.850.1.1.3.4.2.1.1.3
Reading this value will always return 0. Setting this value to turnOff(1) will turn off the main output of the ups. Setting this value to turnOn(2) will turn on the main output of the ups. Setting this value to cycle(3) will turn off the main output, then turn it back on.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER idle(0), turnOff(1), turnOn(2), cycle(3)  

tlpAtsDevicePowerOnDelay 1.3.6.1.4.1.850.1.1.3.4.2.1.1.4
The configurable delay value, which sets the amount of additional time a given device will wait before it connects to a valid AC source. By default the delay value is set to 0. For devices with multiple AC input sources, this delay only applies to the primary input source.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tlpAtsDeviceTotalInputPowerRating 1.3.6.1.4.1.850.1.1.3.4.2.1.1.5
The total input power rating of all phases on the device. This value may not be supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpAtsDeviceTemperatureC 1.3.6.1.4.1.850.1.1.3.4.2.1.1.6
The ambient temperature at or near the ats casing. Temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpAtsDeviceTemperatureF 1.3.6.1.4.1.850.1.1.3.4.2.1.1.7
The ambient temperature at or near the ats casing. Temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpAtsDevicePhaseImbalance 1.3.6.1.4.1.850.1.1.3.4.2.1.1.8
The percentage of imbalance of the three phases. This value is in the range from 0% imbalance to 100% imbalance. The lower the value, the better balanced the phases are. If all load is on a single phase, the imbalance is defined as 100%.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..200  

tlpAtsDeviceOutputPowerTotal 1.3.6.1.4.1.850.1.1.3.4.2.1.1.9
The AC output total power for all circuits.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsDeviceAggregatePowerFactor 1.3.6.1.4.1.850.1.1.3.4.2.1.1.10
The aggregate power factor of all phases.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsDeviceOutputCurrentPrecision 1.3.6.1.4.1.850.1.1.3.4.2.1.1.11
Output current is reported by tlpAtsOutputCurrent, tlpAtsOutputCurrentMin and tlpAtsOutputCurrentMax. These values are all reported in hundredths (0.01A), which accommodates all models; however, on any given device the actual precision may vary. This value describes the actual precision, which can be used as a divisor against the output current values to obtain the true output current measurement. For example, if tlpAtsOutputCurrent reports 530 and tlpAtsDeviceOutputCurrentPrecision is tenths(1), then the actual output current is 5.3.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), tenths(1), hundredths(2)  

tlpAtsDeviceGeneralFault 1.3.6.1.4.1.850.1.1.3.4.2.1.1.12
Indicates whether or not the ats is in a system fault condition. When the ats is in such a fault condition, the condition can be cleared with tlpAtsControlResetGeneralFault.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpAtsInputTable 1.3.6.1.4.1.850.1.1.3.4.3.1.1
The input details of each ats in device table. This is a sparse dependent table, and will contain the number of entries based upon the number of atss managed by the agent as reported by tlpAtsIdentNumAts.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpAtsInputEntry

tlpAtsInputEntry 1.3.6.1.4.1.850.1.1.3.4.3.1.1.1
An entry containing information applicable to a particular primary input phase managed by this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpAtsInputEntry  

tlpAtsInputNominalVoltage 1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.1
The nominal value of the input line voltage. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsInputNominalVoltagePhaseToPhase 1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.2
The nominal value of the input line voltage as measured from phase to phase. This value may not be supported on all models. If not supported, this value will always return zero.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsInputNominalVoltagePhaseToNeutral 1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.3
The nominal value of the input line voltage as measured from phase to neutral. This value may not be supported on all models. If not supported, this value will always return zero.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsInputBadTransferVoltage 1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.4
The minimum line voltage allowed before the unit disconnects the AC input connection.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsInputBadTransferVoltageLowerBound 1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.5
The lower boundary value of tlpAtsInputBadTransferVoltage as dictated by the hardware of the unit.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsInputBadTransferVoltageUpperBound 1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.6
The upper boundary value of tlpAtsInputBadTransferVoltage as dictated by the hardware of the unit.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsInputHighTransferVoltage 1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.7
The maximum line voltage allowed before the unit disconnects the AC input connection.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsInputHighTransferVoltageLowerBound 1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.8
The lower boundary value of tlpAtsInputHighTransferVoltage as dictated by the hardware of the unit.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsInputHighTransferVoltageUpperBound 1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.9
The upper boundary value of tlpAtsInputHighTransferVoltage as dictated by the hardware of the unit.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsInputFairVoltageThreshold 1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.10
The voltage level at which the device will transition between sources.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsInputBadVoltageThreshold 1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.11
The minimum line voltage allowed before the device disconnects the AC input connection.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsInputSourceAvailability 1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.12
The determination as to which of two AC input lines are available. The agent will return either inputSourceA(1) or inputSourceB(2) if only one line is available, or inputSourceAB(3) if both lines are available. The agent will never return none(0) since the device will be powered off if neither line is available.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), inputSourceA(1), inputSourceB(2), inputSourceAB(3)  

tlpAtsInputSourceInUse 1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.13
The determination as to which one of two AC input lines is in use. Not all devices support the reporting of which source is currently in use. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER inputSourceA(0), inputSourceB(1)  

tlpAtsInputSourceTransitionCount 1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.14
The number of times the device transitions between primary and secondary sources. Most devices are limited to 65533 transitions, after which the value will not increment. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsInputCurrentLimit 1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.15
The capacity of each phase conductor in the ats limited by the AC input cord or any other potential limiting factors unique to a given unit. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsInputPhaseTable 1.3.6.1.4.1.850.1.1.3.4.3.1.2
The input phase details of each ats in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpAtsIdentNumInputs and tlpAtsIdentNumPhases per each device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpAtsInputPhaseEntry

tlpAtsInputPhaseEntry 1.3.6.1.4.1.850.1.1.3.4.3.1.2.1
An entry containing information applicable to a particular primary input phase managed by this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpAtsInputPhaseEntry  

tlpAtsInputLineIndex 1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.1
The table row index for the input line on the ats.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsInputPhaseIndex 1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.2
The table row index for the input phase for the input line.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsInputPhaseType 1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.3
Denotes whether measurements are phase to neutral(0) or phase to phase(1).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER phaseToNeutral(0), phaseToPhase(1)  

tlpAtsInputPhaseFrequency 1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.4
The present input frequency for a given phase.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsInputPhaseVoltage 1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.5
The magnitude of the present input voltage for a given phase.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsInputPhaseVoltageMin 1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.6
The minimum input voltage value since the last reset of this value for a given phase. If any value is written to either tlpAtsInputVoltageMin or tlpAtsInputVoltageMax, both will be reset to their appropriate minimum and maximum values.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpAtsInputPhaseVoltageMax 1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.7
The maximum input voltage value since the last reset of this value for a given phase. If any value is written to either tlpAtsInputVoltageMin or tlpAtsInputVoltageMax, both will be reset to their appropriate minimum and maximum values.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpAtsInputPhaseCurrent 1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.8
The magnitude of the present input current for a given phase.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsOutputTable 1.3.6.1.4.1.850.1.1.3.4.3.2.1
The output details of each ats in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpAtsIdentNumOutputs per each device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpAtsOutputEntry

tlpAtsOutputEntry 1.3.6.1.4.1.850.1.1.3.4.3.2.1.1
An entry containing output information applicable to a particular phase managed by this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpAtsOutputEntry  

tlpAtsOutputIndex 1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.1
The table row index for the ats phase.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsOutputPhase 1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.2
Indicates the phase associated with the output line.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER phase1(1), phase2(2), phase3(3)  

tlpAtsOutputPhaseType 1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.3
Denotes whether measurements are phase to neutral(0) or phase to phase(1).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER phaseToNeutral(0), phaseToPhase(1)  

tlpAtsOutputVoltage 1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.4
The magnitude of the present output voltage for a given output line.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsOutputCurrent 1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.5
The output current, in hundredths of amps, for a given phase. The actual precision of this value, whether a whole number, tenths or hundredths, is returned by tlpAtsDeviceOutputCurrentPrecision.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsOutputCurrentMin 1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.6
The minimum current, in hundredths of amps, observed for a given phase since last reset. The actual precision of this value, whether a whole number, tenths or hundredths, is returned by tlpAtsDeviceOutputCurrentPrecision.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsOutputCurrentMax 1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.7
The maximum current, in hundredths of amps, observed for a given phase since last reset. The actual precision of this value, whether a whole number, tenths or hundredths, is returned by tlpAtsDeviceOutputCurrentPrecision.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsOutputActivePower 1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.8
The output power for a given phase.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsOutputPowerFactor 1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.9
The output power factor, in hundredths of a percent, for a given phase.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsOutputSource 1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.10
The present source of output power. The enumeration none(0) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), normal(1)  

tlpAtsOutputFrequency 1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.11
The present output frequency. If not supported, the agent reports ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsOutputCalculatedPowerKVA 1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.12
The calculated amount of apparent power being used.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsOutputCalculatedPowerKW 1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.13
The calculated amount of active power being used.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsOutputCalculated24hrEnergy 1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.14
Estimated 24 hour power consumption using present value of tlpAtsOutputCalculatedPowerKW.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsOutletTable 1.3.6.1.4.1.850.1.1.3.4.3.3.1
The receptacle status details of each ats in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpAtsIdentNumOutlets per each device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpAtsOutletEntry

tlpAtsOutletEntry 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1
An entry containing information applicable to a particular outlet managed by this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpAtsOutletEntry  

tlpAtsOutletIndex 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.1
The table row index for the ats outlet.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsOutletName 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.2
A user-definable string identifying the name of the outlet.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

tlpAtsOutletDescription 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.3
A user-definable string identifying the device(s) connected to the given outlet.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

tlpAtsOutletState 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.4
The current state of the outlet.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), off(1), on(2)  

tlpAtsOutletControllable 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.5
Denotes whether this outlet is controllable.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpAtsOutletCommand 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.6
Reading this value will always return 0. Setting this value to turnOff(1) will turn off the outlet. Setting this value to turnOn(2) will turn on the outlet. Setting this value to cycle(3) will turn the outlet off, then turn it back on.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER idle(0), turnOff(1), turnOn(2), cycle(3)  

tlpAtsOutletVoltage 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.7
The magnitude of the present output voltage for a given outlet. If the voltage measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle voltage measurements is denoted by tlpAtsSupportsOutletVoltage.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsOutletCurrent 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.8
The present output current, in hundredths of amps, of a given outlet. If the current measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle current measurements is denoted by tlpAtsSupportsCurrentPower.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsOutletPower 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.9
The output power of a given outlet. If the power measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle power measurements is denoted by tlpAtsSupportsCurrentPower.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsOutletRampAction 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.10
The ramp action to take on a given outlet when powering on the device. If this receptacle is not controllable, as denoted by tlpAtsOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER remainOff(0), turnOnAfterDelay(1)  

tlpAtsOutletRampDelay 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.11
The number of seconds to delay before powering on the given outlet. If this receptacle is not controllable, as denoted by tlpAtsOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tlpAtsOutletShedAction 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.12
The shed action to take on a given outlet when powering off the device. If this receptacle is not controllable, as denoted by tlpAtsOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER remainOn(0), turnOffAfterDelay(1)  

tlpAtsOutletShedDelay 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.13
The number of seconds to delay before powering off the given outlet. If this receptacle is not controllable, as denoted by tlpAtsOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tlpAtsOutletGroup 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.14
The tlpAtsOutletGroupIndex group index of the respective group to which the given outlet is assigned, or zero (0) if the given outlet is not grouped.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tlpAtsOutletBank 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.15
Indicates on which bank the given outlet is located.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpAtsOutletCircuit 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.16
Indicates on which circuit the given outlet is wired.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpAtsOutletPhase 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.17
Indicates on which phase or phases the given outlet is associated. For single phase devices, this object will always return phase1(1). For 3-phase devices with outlets wired to a single phase, this object will return phase1(1), phase2(2) or phase3(3). For 3-phase devices with outlets wired to two phases, this object will return phase1-2(4) for phases 1 and 2, phase2-3(5) for phases 2 and 3, and phase3-1(6) for phases 3 and 1. Devices that do not report phase connections will return unknown(0).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), phase1(1), phase2(2), phase3(3), phase1-2(4), phase2-3(5), phase3-1(6)  

tlpAtsOutletGroupTable 1.3.6.1.4.1.850.1.1.3.4.3.3.2
The receptacle grouping details of each ats in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpAtsIdentNumOutletGroups per each device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpAtsOutletGroupEntry

tlpAtsOutletGroupEntry 1.3.6.1.4.1.850.1.1.3.4.3.3.2.1
An entry containing information applicable to a particular outlet group managed by this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpAtsOutletGroupEntry  

tlpAtsOutletGroupIndex 1.3.6.1.4.1.850.1.1.3.4.3.3.2.1.1
The table row index for the ats outlet group.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsOutletGroupRowStatus 1.3.6.1.4.1.850.1.1.3.4.3.3.2.1.2
Row status for the tlpAtsOutletGroupTable
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

tlpAtsOutletGroupName 1.3.6.1.4.1.850.1.1.3.4.3.3.2.1.3
The name of this outlet group.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

tlpAtsOutletGroupDescription 1.3.6.1.4.1.850.1.1.3.4.3.3.2.1.4
A description for this outlet group.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

tlpAtsOutletGroupState 1.3.6.1.4.1.850.1.1.3.4.3.3.2.1.5
The current state of the outlet group. This value will report off(1) if all outlets in the group are off, on(2) if all outlets in the group are on, mixed(3) if some outlets in the group are off and others are on, or unknown(0) if the state of the outlets cannot be determined.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), off(1), on(2), mixed(3)  

tlpAtsOutletGroupCommand 1.3.6.1.4.1.850.1.1.3.4.3.3.2.1.6
Reading this value will always return 0. Setting this value to turnOff(1) will turn off every outlet associated with the group. Setting this value to turnOn(2) will turn on every outlet associated with the group. Setting this value to cycle(3) will turn off every outlet associated with the group, then turn each outlet back on.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER turnOff(1), turnOn(2), cycle(3)  

tlpAtsCircuitTable 1.3.6.1.4.1.850.1.1.3.4.3.4.1
A list of ats circuit table entries. The number of entries is given by the value of tlpAtsIdentNumCircuits.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpAtsCircuitEntry

tlpAtsCircuitEntry 1.3.6.1.4.1.850.1.1.3.4.3.4.1.1
An entry containing information applicable to a particular circuit managed by this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpAtsCircuitEntry  

tlpAtsCircuitIndex 1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.1
The table row index for the ats circuit.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsCircuitPhase 1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.2
Indicates on which phase or phases the given circuit is wired. For single phase devices, this object will always return phase1(1). For 3-phase devices with outlets wired to a single phase, this object will return phase1(1), phase2(2) or phase3(3). For 3-phase devices with outlets wired to two phases, this object will return phase1-2(4) for phases 1 and 2, phase2-3(5) for phases 2 and 3, and phase3-1(6) for phases 3 and 1. Devices that do not report phase connections will return unknown(0).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), phase1(1), phase2(2), phase3(3), phase1-2(4), phase2-3(5), phase3-1(6)  

tlpAtsCircuitInputVoltage 1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.3
The input voltage for a circuit.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpAtsCircuitTotalCurrent 1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.4
The total current for all receptacles in a given circuit.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpAtsCircuitCurrentLimit 1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.5
The current capacity of a circuit in the system limited by the circuit breaker or wiring used in a given unit.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpAtsCircuitCurrentMin 1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.6
The minimum total current for all receptacles in a given circuit since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpAtsCircuitCurrentMax 1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.7
The maximum total current for all receptacles in a given circuit since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpAtsCircuitTotalPower 1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.8
The total power for all receptacles in a given circuit.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpAtsCircuitPowerFactor 1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.9
The power factor for all receptacles in a given circuit.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..200  

tlpAtsCircuitUtilization 1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.10
The percentage of utilization of a given circuit. This is typically a calculation of tlpAtsCircuitTotalCurrent / tlpAtsCircuitCurrentLimit.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsBreakerTable 1.3.6.1.4.1.850.1.1.3.4.3.5.1
A list of ats bank breaker table entries. The number of entries is given by the value of tlpAtsIdentNumBreakers.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpAtsBreakerEntry

tlpAtsBreakerEntry 1.3.6.1.4.1.850.1.1.3.4.3.5.1.1
An entry containing information applicable to a particular bank breaker managed by this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpAtsBreakerEntry  

tlpAtsBreakerIndex 1.3.6.1.4.1.850.1.1.3.4.3.5.1.1.1
The table row index for the ats bank breaker.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsBreakerStatus 1.3.6.1.4.1.850.1.1.3.4.3.5.1.1.2
Indicates whether the bank breaker is open(0), closed(1) or not installed(2).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER open(0), closed(1), notInstalled(2)  

tlpAtsHeatsinkTable 1.3.6.1.4.1.850.1.1.3.4.3.6.1
A list of ats heatsink thermistor table entries. The number of entries is given by the value of tlpAtsIdentNumHeatsinks.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpAtsHeatsinkEntry

tlpAtsHeatsinkEntry 1.3.6.1.4.1.850.1.1.3.4.3.6.1.1
An entry containing information applicable to a particular heatsink thermistor managed by this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpAtsHeatsinkEntry  

tlpAtsHeatsinkIndex 1.3.6.1.4.1.850.1.1.3.4.3.6.1.1.1
The table row index for the ats heatsink thermistor.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsHeatsinkStatus 1.3.6.1.4.1.850.1.1.3.4.3.6.1.1.2
Indicates whether the heatsink thermistor is available. The entry will return notAvailable(0) if a thermistor is either non-existent or disconnected, or available(1) when connected.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notAvailable(0), available(1)  

tlpAtsHeatsinkTemperatureC 1.3.6.1.4.1.850.1.1.3.4.3.6.1.1.3
The temperature at the heatsink thermistor in tenths degrees Celsius. Heatsink temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpAtsHeatsinkTemperatureF 1.3.6.1.4.1.850.1.1.3.4.3.6.1.1.4
The temperature at the heatsink thermistor in tenths degrees Fahrenheit. Heatsink temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpAtsControlTable 1.3.6.1.4.1.850.1.1.3.4.4.1
The actionable controls for each ats in device table. This is a sparse dependent table, and will contain some subset of devices that are atss.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpAtsControlEntry

tlpAtsControlEntry 1.3.6.1.4.1.850.1.1.3.4.4.1.1
An entry containing controls for a particular ats.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpAtsControlEntry  

tlpAtsControlRamp 1.3.6.1.4.1.850.1.1.3.4.4.1.1.1
Set to TRUE to initiate the pre-designated ramp sequence on the ats.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

tlpAtsControlShed 1.3.6.1.4.1.850.1.1.3.4.4.1.1.2
Set to TRUE to initiate the pre-designated shed sequence on the ats.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

tlpAtsControlAtsOn 1.3.6.1.4.1.850.1.1.3.4.4.1.1.3
Set to TRUE to turn the ats on.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

tlpAtsControlAtsOff 1.3.6.1.4.1.850.1.1.3.4.4.1.1.4
Set to TRUE to turn the ats off.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

tlpAtsControlAtsReboot 1.3.6.1.4.1.850.1.1.3.4.4.1.1.5
Set to TRUE to reboot the ats.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

tlpAtsControlResetGeneralFault 1.3.6.1.4.1.850.1.1.3.4.4.1.1.6
Set to TRUE to reset the general fault alarm indicated by tlpAtsDeviceGeneralFault.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

tlpAtsConfigTable 1.3.6.1.4.1.850.1.1.3.4.5.1
The configuration options of each ats in device table. This is a sparse dependent table, and will contain some subset of devices that are atss. Not all options are available on all atss.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpAtsConfigEntry

tlpAtsConfigEntry 1.3.6.1.4.1.850.1.1.3.4.5.1.1
An entry containing configuration options for a particular ats.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpAtsConfigEntry  

tlpAtsConfigInputVoltage 1.3.6.1.4.1.850.1.1.3.4.5.1.1.1
The nominal value of the input line voltage. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME. This value may not be writable on all models. If not writable, the value will be rejected and an appropriate error message will be returned.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpAtsConfigSourceSelect 1.3.6.1.4.1.850.1.1.3.4.5.1.1.2
The determination as to which of two AC input lines is designated as the primary input source. The other is designated as the secondary input source. This value will always return inputSourceA(1) for devices with a single input source. Setting this value is supported only on selected models.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER inputSourceA(1), inputSourceB(2)  

tlpAtsConfigSource1ReturnTime 1.3.6.1.4.1.850.1.1.3.4.5.1.1.3
The nominal time to delay a transition to Source 1, if it is the preferred source.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpAtsConfigSource2ReturnTime 1.3.6.1.4.1.850.1.1.3.4.5.1.1.4
The nominal time to delay a transition to Source 2, if it is the preferred source.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpAtsConfigAutoRampOnTransition 1.3.6.1.4.1.850.1.1.3.4.5.1.1.5
When enabled(1), the ats should perform its preconfigured ramp sequence when the input source transfers from its designated secondary source to its designated primary source. This value not supported on all ats devices. If not supported, then this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

tlpAtsConfigAutoShedOnTransition 1.3.6.1.4.1.850.1.1.3.4.5.1.1.6
When enabled(1), the ats should perform its preconfigured shed sequence when the input source transfers from its designated primary source to its designated secondary source. This value not supported on all ats devices. If not supported, then this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

tlpAtsConfigVoltageRangeOldTable 1.3.6.1.4.1.850.1.1.3.4.5.2
The voltage range options in this table is intended to configure the operating voltages of an ats. This is a sparse dependent table, and will contain some subset of devices that are atss. All voltage points defined in this table are listed in a specific order from high to low. All voltage points must satisfy the conditions and ranges defined for each point. Any point violating any of the relative limits will be rejected. For optimal operation, it is recommended that tlpAtsConfigHighVoltageReset be set lower than tlpAtsConfigHighVoltageTransfer by a margin no less than 1% of tlpAtsConfigHighVoltageTransfer; and that tlpAtsConfigSource1TransferReset (tlpAtsConfigSource2TransferReset) be set higher than tlpAtsConfigSource1BrownoutSet (tlpAtsConfigSource2BrownoutSet) by a margin no less than 1% of tlpAtsConfigSource1BrownoutSet (tlpAtsConfigSource2BrownoutSet). *The upper limit of line voltage is tlpAtsInputHighTransferVoltageUpperBound. The lower limit of line voltage is tlpAtsInputBadTransferVoltageLowerBound. All minimum and maximum limits for each voltage point are all exclusive unless indicated otherwise. This table in its entirety is obsolete and replaced by tlpAtsConfigVoltageRangeTable.
Status: obsolete Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpAtsConfigVoltageRangeOldEntry

tlpAtsConfigVoltageRangeOldEntry 1.3.6.1.4.1.850.1.1.3.4.5.2.1
An entry containing voltage range configuration options for a particular ats.
Status: obsolete Access: not-accessible
OBJECT-TYPE    
  TlpAtsConfigVoltageRangeOldEntry  

tlpAtsConfigHighVoltageTransferOld 1.3.6.1.4.1.850.1.1.3.4.5.2.1.1
The maximum line voltage allowed before the unit disconnects the AC input connection. The maximum value allowed is dictated by tlpAtsInputHighTransferVoltageUpperBound (inclusively). The minimum value allowed is dictated by tlpAtsConfigHighVoltageResetOld. This value may not be configurable on all models. If not supported, this value will return ERROR_NO_SUCH_NAME.
Status: obsolete Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpAtsConfigHighVoltageResetOld 1.3.6.1.4.1.850.1.1.3.4.5.2.1.2
If a unit is disconnected due to over-voltage, the line voltage has to fall below this value before the unit re-connects the AC input connection. The maximum value allowed is dictated by tlpAtsConfigHighVoltageTransferOld. The minimum value allowed is dictated by the greater of tlpAtsConfigSource1TransferResetOld and tlpAtsConfigSource2TransferResetOld. If not supported, this value will return ERROR_NO_SUCH_NAME.
Status: obsolete Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpAtsConfigSource1TransferResetOld 1.3.6.1.4.1.850.1.1.3.4.5.2.1.3
If input source 1 voltage level is above this value, a unit connected to source 2 will transition to source 1 (if it is the preferred source). The maximum value allowed is dictated by tlpAtsConfigHighVoltageResetOld. The minimum value allowed is dictated by tlpAtsConfigSource1BrownoutSetOld. If not supported, this value will return ERROR_NO_SUCH_NAME.
Status: obsolete Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpAtsConfigSource1BrownoutSetOld 1.3.6.1.4.1.850.1.1.3.4.5.2.1.4
This value dictates the voltage level below which source 1 goes into a brown out condition. The maximum value allowed is dictated by tlpAtsConfigSource1TransferResetOld. The minimum value allowed is dictated by tlpAtsConfigSource1TransferSetOld. If not supported, this value will return ERROR_NO_SUCH_NAME.
Status: obsolete Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpAtsConfigSource1TransferSetOld 1.3.6.1.4.1.850.1.1.3.4.5.2.1.5
If input source 1 voltage level falls below this value, a unit connected to source 1 will transition to source 2 (if it is in fair condition as denoted by tlpAtsConfigSource2TransferSetOld). The maximum value allowed is dictated by tlpAtsConfigSource1BrownoutSetOld. The minimum value allowed is dictated by tlpAtsConfigLowVoltageResetOld. If not supported, this value will return ERROR_NO_SUCH_NAME.
Status: obsolete Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpAtsConfigSource2TransferResetOld 1.3.6.1.4.1.850.1.1.3.4.5.2.1.6
If input source 2 voltage level is above this value, a unit connected to source 1 will transition to source 2 (if it is the preferred source). The maximum value allowed is dictated by tlpAtsConfigHighVoltageResetOld. The minimum value allowed is dictated by tlpAtsConfigSource2BrownoutSetOld. If not supported, this value will return ERROR_NO_SUCH_NAME.
Status: obsolete Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpAtsConfigSource2BrownoutSetOld 1.3.6.1.4.1.850.1.1.3.4.5.2.1.7
This value dictates the voltage level below which source 2 goes into a brown out condition. The maximum value allowed is dictated by tlpAtsConfigSource2TransferResetOld. The minimum value allowed is dictated by tlpAtsConfigSource2TransferSetOld. If not supported, this value will return ERROR_NO_SUCH_NAME.
Status: obsolete Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpAtsConfigSource2TransferSetOld 1.3.6.1.4.1.850.1.1.3.4.5.2.1.8
If input source 2 voltage level falls below this value, a unit connected to source 2 will transition to source 1 (if it is in fair condition as denoted by tlpAtsConfigSource1TransferSetOld). The maximum value allowed is dictated by tlpAtsConfigSource2BrownoutSetOld. The minimum value allowed is dictated by tlpAtsConfigLowVoltageResetOld. If not supported, this value will return ERROR_NO_SUCH_NAME.
Status: obsolete Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpAtsConfigLowVoltageResetOld 1.3.6.1.4.1.850.1.1.3.4.5.2.1.9
If a unit is disconnected due to under-voltage or is not powered up yet, the line voltage has to rise above this value before the unit gets connected to the AC input connection. The maximum value allowed is dictated by the lesser value of tlpAtsConfigSource1TransferSetOld and tlpAtsConfigSource2TransferSetOld. The minimum value allowed is dictated by tlpAtsConfigLowVoltageTransferOld. If not supported, this value will return ERROR_NO_SUCH_NAME.
Status: obsolete Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpAtsConfigLowVoltageTransferOld 1.3.6.1.4.1.850.1.1.3.4.5.2.1.10
The minimum line voltage allowed before the unit disconnects the AC input connection. The maximum value allowed is dictated by tlpAtsConfigLowVoltageResetOld. The minimum value allowed is dictated by tlpAtsInputBadTransferVoltageLowerBound (inclusively). If not supported, this value will return ERROR_NO_SUCH_NAME.
Status: obsolete Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpAtsConfigVoltageRangeLimitsTable 1.3.6.1.4.1.850.1.1.3.4.5.3
The voltage range table, as documented by tlpAtsConfigVoltageRangeTable requires that all changes adhere with stack order, from high transfer voltage down to low transfer voltage. In addition to stack order, certain voltage range values have limits defining the absolute minimum and absolute maximum for such values. Any voltage value violating any respective limit defined herein will be rejected.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpAtsConfigVoltageRangeLimitsEntry

tlpAtsConfigVoltageRangeLimitsEntry 1.3.6.1.4.1.850.1.1.3.4.5.3.1
An entry containing voltage range limits configuration options for a particular ats.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpAtsConfigVoltageRangeLimitsEntry  

tlpAtsConfigSourceBrownoutSetMinimum 1.3.6.1.4.1.850.1.1.3.4.5.3.1.1
This value dictates the absolute lower limit by which tlpAtsConfigSource1BrownoutSet and tlpAtsConfigSource2BrownoutSet can be set. tlpAtsConfigSource1TransferSet and tlpAtsConfigSource2TransferSet, respectively, are also used when determining the lowest value a brownout value can be set at any given time. If not supported, this value will return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpAtsConfigSourceBrownoutSetMaximum 1.3.6.1.4.1.850.1.1.3.4.5.3.1.2
This value dictates the absolute upper limit by which tlpAtsConfigSource1BrownoutSet and tlpAtsConfigSource2BrownoutSet can be set. tlpAtsConfigSource1TransferReset and tlpAtsConfigSource2TransferReset, respectively, are also used when determining the greatest value a brownout value can be set at any given time. If not supported, this value will return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpAtsConfigSourceTransferSetMinimum 1.3.6.1.4.1.850.1.1.3.4.5.3.1.3
This value dictates the absolute lower limit by which tlpAtsConfigSource1TransferSet and tlpAtsConfigSource2TransferSet can be set. tlpAtsConfigLowVoltageReset is also used when determining the lowest value a transferset value can be set at any given time. If not supported, this value will return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpAtsConfigSourceTransferSetMaximum 1.3.6.1.4.1.850.1.1.3.4.5.3.1.4
This value dictates the absolute upper limit by which tlpAtsConfigSource1TransferSet and tlpAtsConfigSource2TransferSet can be set. tlpAtsConfigSource1BrownoutSet and tlpAtsConfigSource2BrownoutSet, respectively, are also used when determining the greatest value a transferset value can be set at any given time. If not supported, this value will return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpAtsConfigThresholdTable 1.3.6.1.4.1.850.1.1.3.4.5.4
The configurable threshold options of each ats in device table. This is a sparse dependent table, and will contain some subset of devices that are atss. Not all options are available on all atss.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpAtsConfigThresholdEntry

tlpAtsConfigThresholdEntry 1.3.6.1.4.1.850.1.1.3.4.5.4.1
An entry containing configurable threshold options for a particular ats.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpAtsConfigThresholdEntry  

tlpAtsConfigOutputCurrentThreshold 1.3.6.1.4.1.850.1.1.3.4.5.4.1.1
The output current measurement at which an over current condition is reported. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpAtsConfigOverTemperatureThreshold 1.3.6.1.4.1.850.1.1.3.4.5.4.1.2
The system temperature at which an over temperature condition is reported. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpAtsConfigOverVoltageThreshold 1.3.6.1.4.1.850.1.1.3.4.5.4.1.3
The input voltage measurement at which an over voltage condition is reported. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpAtsConfigOverLoadThreshold 1.3.6.1.4.1.850.1.1.3.4.5.4.1.4
The system load at which an overload condition is reported. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpAtsConfigVoltageRangeTable 1.3.6.1.4.1.850.1.1.3.4.5.5
The voltage range options in this table is intended to configure the operating voltages of an ats. This is a sparse dependent table, and will contain some subset of devices that are atss. All voltage points defined in this table are listed in a specific order from high to low. All voltage points must satisfy the conditions and ranges defined for each point. Any point violating any of the relative limits will be rejected. For optimal operation, it is recommended that tlpAtsConfigHighVoltageReset be set lower than tlpAtsConfigHighVoltageTransfer by a margin no less than 1% of tlpAtsConfigHighVoltageTransfer; and that tlpAtsConfigSource1TransferReset (tlpAtsConfigSource2TransferReset) be set higher than tlpAtsConfigSource1BrownoutSet (tlpAtsConfigSource2BrownoutSet) by a margin no less than 1% of tlpAtsConfigSource1BrownoutSet (tlpAtsConfigSource2BrownoutSet). *The upper limit of line voltage is tlpAtsInputHighTransferVoltageUpperBound. The lower limit of line voltage is tlpAtsInputBadTransferVoltageLowerBound. All minimum and maximum limits for each voltage point are all exclusive unless indicated otherwise.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpAtsConfigVoltageRangeEntry

tlpAtsConfigVoltageRangeEntry 1.3.6.1.4.1.850.1.1.3.4.5.5.1
An entry containing voltage range configuration options for a particular ats.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpAtsConfigVoltageRangeEntry  

tlpAtsConfigHighVoltageTransfer 1.3.6.1.4.1.850.1.1.3.4.5.5.1.1
The maximum line voltage allowed on the input source before the unit disconnects the AC input connection. tlpAtsConfigHighVoltageTransfer is the same value for both input sources on some units. On such units, changing this value on one source will change the value on the other source. The maximum value allowed is dictated by tlpAtsInputHighTransferVoltageUpperBound (inclusively). The minimum value allowed is dictated by tlpAtsConfigHighVoltageReset. This value may not be configurable on all models. If not supported, this value will return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpAtsConfigHighVoltageReset 1.3.6.1.4.1.850.1.1.3.4.5.5.1.2
If an input connection is disconnected due to over-voltage, the line voltage on the input source has to fall below this value before the unit re-connects the AC input connection for the input source. tlpAtsConfigHighVoltageReset is the same value for both input sources on some units. On such units, changing this value on one source will change the value on the other source. The maximum value allowed is dictated by tlpAtsConfigHighVoltageTransfer. On units where this is the same value for both sources, the minimum value allowed is dictated by the greater of tlpAtsConfigTransferReset.1 and tlpAtsConfigTransferReset.2. On units where the value is distinct for each source, the minimum value allowed is dictated solely by this source's tlpAtsConfigTransferReset. If not supported, this value will return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpAtsConfigTransferReset 1.3.6.1.4.1.850.1.1.3.4.5.5.1.3
If input source voltage level is above this value, a unit connected to this other input source will transition to this input source (if it is the preferred source). The maximum value allowed is dictated by tlpAtsConfigHighVoltageReset. The minimum value allowed is dictated by tlpAtsConfigBrownoutSet. If not supported, this value will return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpAtsConfigBrownoutSet 1.3.6.1.4.1.850.1.1.3.4.5.5.1.4
This value dictates the voltage level below which the input source goes into a brown out condition. The maximum value allowed is dictated by tlpAtsConfigTransferReset. The minimum value allowed is dictated by tlpAtsConfigTransferSet. If not supported, this value will return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpAtsConfigTransferSet 1.3.6.1.4.1.850.1.1.3.4.5.5.1.5
If input source voltage level falls below this value, a unit connected to this input source will transition to other input source (if it is in fair condition as denoted by tlpAtsConfigTransferSet). The maximum value allowed is dictated by tlpAtsConfigBrownoutSet. The minimum value allowed is dictated by tlpAtsConfigLowVoltageReset. If not supported, this value will return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpAtsConfigLowVoltageReset 1.3.6.1.4.1.850.1.1.3.4.5.5.1.6
If a unit is disconnected due to under-voltage or is not powered up yet, the line voltage has to rise above this value before the unit gets connected to the AC input connection. tlpAtsConfigLowVoltageReset is the same value for both input sources. As such, changing this value on one source will change the value on the other source. The maximum value allowed is dictated by the lesser value of tlpAtsConfigTransferSet.1 and tlpAtsConfigTransferSet.2. The minimum value allowed is dictated by tlpAtsConfigLowVoltageTransfer. If not supported, this value will return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpAtsConfigLowVoltageTransfer 1.3.6.1.4.1.850.1.1.3.4.5.5.1.7
The minimum line voltage allowed before the unit disconnects the AC input connection. tlpAtsConfigLowVoltageTransfer is the same value for both input sources. As such, changing this value on one source will change the value on the other source. The maximum value allowed is dictated by tlpAtsConfigLowVoltageReset. The minimum value allowed is dictated by tlpAtsInputBadTransferVoltageLowerBound (inclusively). If not supported, this value will return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpAtsConfigPhaseThresholdTable 1.3.6.1.4.1.850.1.1.3.4.5.6
The configuration options of each Ats in device table. This is a sparse dependent table, and will contain some subset of devices that are Atss. Not all options are available on all Atss.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpAtsConfigPhaseThresholdEntry

tlpAtsConfigPhaseThresholdEntry 1.3.6.1.4.1.850.1.1.3.4.5.6.1
An entry containing threshold configuration options for a particular Ats.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpAtsConfigPhaseThresholdEntry  

tlpAtsPhaseIndex 1.3.6.1.4.1.850.1.1.3.4.5.6.1.1
The table row index for the Ats phase.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAtsConfigOutputCurrentThresholdTolerance 1.3.6.1.4.1.850.1.1.3.4.5.6.1.2
The threshold tolerance value used together with output current high/low threshold to evaluate output current high/low condition.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpAtsConfigOutputCurrentHighThreshold 1.3.6.1.4.1.850.1.1.3.4.5.6.1.3
The value at which a output current high condition is declared.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpAtsConfigOutputCurrentLowThreshold 1.3.6.1.4.1.850.1.1.3.4.5.6.1.4
The value at which a output current low condition is declared.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpCoolingIdentNumCooling 1.3.6.1.4.1.850.1.1.3.5.1.1
The number of cooling devices that this agent is currently managing.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpCoolingCurrentTable 1.3.6.1.4.1.850.1.1.3.5.3.3
The input current for each cooling device in device table. This is a sparse dependent table, and will contain the number of entries based upon the number of cooling device managed by the agent as reported by tlpCoolingIdentNumCooling.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpCoolingCurrentEntry

tlpCoolingCurrentEntry 1.3.6.1.4.1.850.1.1.3.5.3.3.1
An entry containing input current for a particular cooling device.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpCoolingCurrentEntry  

tlpCoolingUnitCurrent 1.3.6.1.4.1.850.1.1.3.5.3.3.1.1
The total current draw of the unit in tenths of Amps. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpCoolingCompressorCurrent 1.3.6.1.4.1.850.1.1.3.5.3.3.1.2
The compressor current draw of the unit in tenths of Amps. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpCoolingEvaporatorFanCurrent 1.3.6.1.4.1.850.1.1.3.5.3.3.1.3
The current draw of the evaporator fan in tenths of Amps. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpCoolingCondenserFanCurrent 1.3.6.1.4.1.850.1.1.3.5.3.3.1.4
The current draw of the condenser fan in tenths of Amps. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpCoolingTemperatureFahrenheitTable 1.3.6.1.4.1.850.1.1.3.5.3.1.1
The temperature details for each cooling device in device table. This is a sparse dependent table, and will contain the number of entries based upon the number of cooling device managed by the agent as reported by tlpCoolingIdentNumCooling.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpCoolingTemperatureFahrenheitEntry

tlpCoolingTemperatureFahrenheitEntry 1.3.6.1.4.1.850.1.1.3.5.3.1.1.1
An entry containing temperature details for a particular cooling device.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpCoolingTemperatureFahrenheitEntry  

tlpCoolingAmbientDegF 1.3.6.1.4.1.850.1.1.3.5.3.1.1.1.1
The ambient temperature in tenths degrees Fahrenheit. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpCoolingSupplyAirDegF 1.3.6.1.4.1.850.1.1.3.5.3.1.1.1.2
The temperature of the air entering the cooling unit in tenths degrees Fahrenheit. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpCoolingReturnAirDegF 1.3.6.1.4.1.850.1.1.3.5.3.1.1.1.3
The temperature of the air entering the cooling unit in tenths degrees Fahrenheit. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpCoolingCondenserInletDegF 1.3.6.1.4.1.850.1.1.3.5.3.1.1.1.4
The temperature of the air entering the condenser in tenths degrees Fahrenheit. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpCoolingEvaporatorDegF 1.3.6.1.4.1.850.1.1.3.5.3.1.1.1.5
The temperature of the evaporator surface in tenths degrees Fahrenheit. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpCoolingSuctionDegF 1.3.6.1.4.1.850.1.1.3.5.3.1.1.1.6
The temperature of the low pressure refrigerant line in tenths degrees Fahrenheit. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpCoolingRemoteDegF 1.3.6.1.4.1.850.1.1.3.5.3.1.1.1.7
The external remote temperature in tenths degrees Fahrenheit. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpCoolingCondenserOutletDegF 1.3.6.1.4.1.850.1.1.3.5.3.1.1.1.8
The temperature of the air leaving the condenser in tenths degrees Fahrenheit. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpCoolingTemperatureCelsiusTable 1.3.6.1.4.1.850.1.1.3.5.3.1.2
The temperature details for each cooling device in device table. This is a sparse dependent table, and will contain the number of entries based upon the number of cooling device managed by the agent as reported by tlpCoolingIdentNumCooling.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpCoolingTemperatureCelsiusEntry

tlpCoolingTemperatureCelsiusEntry 1.3.6.1.4.1.850.1.1.3.5.3.1.2.1
An entry containing temperature details for a particular cooling device.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpCoolingTemperatureCelsiusEntry  

tlpCoolingAmbientDegC 1.3.6.1.4.1.850.1.1.3.5.3.1.2.1.1
The ambient temperature in tenths degrees Celsius. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpCoolingSupplyAirDegC 1.3.6.1.4.1.850.1.1.3.5.3.1.2.1.2
The temperature of the air entering the cooling unit in tenths degrees Celsius. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpCoolingReturnAirDegC 1.3.6.1.4.1.850.1.1.3.5.3.1.2.1.3
The temperature of the air entering the cooling unit in tenths degrees Celsius. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpCoolingCondenserInletDegC 1.3.6.1.4.1.850.1.1.3.5.3.1.2.1.4
The temperature of the air entering the condenser in tenths degrees Celsius. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpCoolingEvaporatorDegC 1.3.6.1.4.1.850.1.1.3.5.3.1.2.1.5
The temperature of the evaporator surface in tenths degrees Celsius. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpCoolingSuctionDegC 1.3.6.1.4.1.850.1.1.3.5.3.1.2.1.6
The temperature of the low pressure refrigerant line in tenths degrees Celsius. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpCoolingRemoteDegC 1.3.6.1.4.1.850.1.1.3.5.3.1.2.1.7
The external remote temperature in tenths degrees Celsius. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpCoolingCondenserOutletDegC 1.3.6.1.4.1.850.1.1.3.5.3.1.2.1.8
The temperature of the air leaving the condenser in tenths degrees Celsius. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

tlpCoolingPressureMpaTable 1.3.6.1.4.1.850.1.1.3.5.3.2.1
The pressure detail for each cooling device in device table. This is a sparse dependent table, and will contain the number of entries based upon the number of cooling device managed by the agent as reported by tlpCoolingIdentNumCooling.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpCoolingPressureMpaEntry

tlpCoolingPressureMpaEntry 1.3.6.1.4.1.850.1.1.3.5.3.2.1.1
An entry containing pressure details for a particular cooling device.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpCoolingPressureMpaEntry  

tlpCoolingSuctionPressureMpa 1.3.6.1.4.1.850.1.1.3.5.3.2.1.1.1
The pressure of the compressor discharge line in tenths of Mpa. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpCoolingDischargePressureMpa 1.3.6.1.4.1.850.1.1.3.5.3.2.1.1.2
The pressure of the compressor discharge line in tenths of Mpa. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpCoolingPressurePsiTable 1.3.6.1.4.1.850.1.1.3.5.3.2.2
The pressure detail for each cooling device in device table. This is a sparse dependent table, and will contain the number of entries based upon the number of cooling device managed by the agent as reported by tlpCoolingIdentNumCooling.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpCoolingPressurePsiEntry

tlpCoolingPressurePsiEntry 1.3.6.1.4.1.850.1.1.3.5.3.2.2.1
An entry containing pressure details for a particular cooling device.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpCoolingPressurePsiEntry  

tlpCoolingSuctionPressurePsi 1.3.6.1.4.1.850.1.1.3.5.3.2.2.1.1
The pressure of the compressor discharge line in tenths of Psi. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpCoolingDischargePressurePsi 1.3.6.1.4.1.850.1.1.3.5.3.2.2.1.2
The pressure of the compressor discharge line in tenths of Psi. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpCoolingDynamicTable 1.3.6.1.4.1.850.1.1.3.5.3.4
The dynamic detail for each cooling device in device table. This is a sparse dependent table, and will contain the number of entries based upon the number of cooling device managed by the agent as reported by tlpCoolingIdentNumCooling.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpCoolingDynamicEntry

tlpCoolingDynamicEntry 1.3.6.1.4.1.850.1.1.3.5.3.4.1
An entry dynamic details for a particular cooling device.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpCoolingDynamicEntry  

tlpCoolingEvaporatorFanSpeed 1.3.6.1.4.1.850.1.1.3.5.3.4.1.1
The current speed of the evaporator fan. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), low(1), mediumLow(2), medium(3), mediumHigh(4), high(5), auto(6)  

tlpCoolingCondenserFanSpeed 1.3.6.1.4.1.850.1.1.3.5.3.4.1.2
The current speed of the condenser fan. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), low(1), mediumLow(2), medium(3), mediumHigh(4), high(5), auto(6)  

tlpCoolingCompressorFrequency 1.3.6.1.4.1.850.1.1.3.5.3.4.1.3
The operating mechanical frequency(Hz) of the compressor. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpCoolingEEVSteps 1.3.6.1.4.1.850.1.1.3.5.3.4.1.4
The current EEV steps. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

tlpCoolingRuntimeTable 1.3.6.1.4.1.850.1.1.3.5.3.5
The runtime detail for each cooling device in device table. This is a sparse dependent table, and will contain the number of entries based upon the number of cooling device managed by the agent as reported by tlpCoolingIdentNumCooling.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpCoolingRuntimeEntry

tlpCoolingRuntimeEntry 1.3.6.1.4.1.850.1.1.3.5.3.5.1
An entry containing runtime for a particular cooling device.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpCoolingRuntimeEntry  

tlpCoolingCompressorRunDays 1.3.6.1.4.1.850.1.1.3.5.3.5.1.1
Total days the compressor has been under operation. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpCoolingCondensatePumpRunDays 1.3.6.1.4.1.850.1.1.3.5.3.5.1.2
Total days the condensate pump has been under operation. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpCoolingAirFilterRunHours 1.3.6.1.4.1.850.1.1.3.5.3.5.1.3
Total hours the air filter has been under operation. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpCoolingEvaporatorFanRunDays 1.3.6.1.4.1.850.1.1.3.5.3.5.1.4
Total days the evaporator fan has been under operation. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpCoolingCondenserFanRunDays 1.3.6.1.4.1.850.1.1.3.5.3.5.1.5
Total days the condenser fan has been under operation. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpCoolingAtomizerRunDays 1.3.6.1.4.1.850.1.1.3.5.3.5.1.6
Total days the atomizer has been under operation. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpCoolingStatusTable 1.3.6.1.4.1.850.1.1.3.5.3.6
The status detail for each cooling device in device table. This is a sparse dependent table, and will contain the number of entries based upon the number of cooling device managed by the agent as reported by tlpCoolingIdentNumCooling.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpCoolingStatusEntry

tlpCoolingStatusEntry 1.3.6.1.4.1.850.1.1.3.5.3.6.1
An entry containing status for a particular cooling device.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpCoolingStatusEntry  

tlpCoolingOperatingMode 1.3.6.1.4.1.850.1.1.3.5.3.6.1.1
The current operating mode. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), idle(1), cooling(2), shuttingDown(3), dehumidifying(4), defrosting(5), notConnected(6)  

tlpCoolingCoolOutput 1.3.6.1.4.1.850.1.1.3.5.3.6.1.2
The current cooling output of the cooling device in tenth of kilowatt. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpCoolingAlarmStatus 1.3.6.1.4.1.850.1.1.3.5.3.6.1.3
The current alarm status of the cooling device. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(0), warning(1), critical(2)  

tlpCoolingCompressorStatus 1.3.6.1.4.1.850.1.1.3.5.3.6.1.4
The current operating status of compressor. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1)  

tlpCoolingWaterStatus 1.3.6.1.4.1.850.1.1.3.5.3.6.1.5
The current water status of cooling unit. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notFull(0), full(1)  

tlpCoolingControlTable 1.3.6.1.4.1.850.1.1.3.5.4.1
The actionable controls for each cooling device in device table. This is a sparse dependent table, and will contain some subset of devices that are cooling device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpCoolingControlEntry

tlpCoolingControlEntry 1.3.6.1.4.1.850.1.1.3.5.4.1.1
An entry containing controls for a particular cooling device.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpCoolingControlEntry  

tlpCoolingOnOff 1.3.6.1.4.1.850.1.1.3.5.4.1.1.1
Turn the unit on or off.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER turnOffUnit(0), turnOnUnit(1)  

tlpCoolingConfigTable 1.3.6.1.4.1.850.1.1.3.5.5.1
The configuration details for each each cooling device in device table. This is a sparse dependent table, and will contain some subset of devices that are cooling device. Not all options are available on all cooling devices.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpCoolingConfigEntry

tlpCoolingConfigEntry 1.3.6.1.4.1.850.1.1.3.5.5.1.1
An entry configuration details for a particular cooling device.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpCoolingConfigEntry  

tlpCoolingAutoStart 1.3.6.1.4.1.850.1.1.3.5.5.1.1.1
Specifies if the unit should start automatically on power up. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

tlpCoolingFanSpeed 1.3.6.1.4.1.850.1.1.3.5.5.1.1.2
Specifies the actual speed of the evaporator fan. Setting the fan speed to auto(6) will enable tlpCoolingAutoFanSpeed; however, on most units getting the fan speed will return the actual fan speed regardless whether auto fan speed is enabled or disabled. The value auto(6) is returned only on units that do not report the actual fan speed when auto fan speed is enabled. Not all values are supported on all cooling units. Invalid values will return an appropriate error when accessed. If not supported, this value will always return ERROR_NO_SUCH_NAME
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(0), low(1), mediumLow(2), medium(3), mediumHigh(4), high(5), auto(6)  

tlpCoolingControlType 1.3.6.1.4.1.850.1.1.3.5.5.1.1.3
Specifies which temperature is used as a control point. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER returnAirTemperature(0), remoteTemperature(1)  

tlpCoolingDisplayUnits 1.3.6.1.4.1.850.1.1.3.5.5.1.1.4
Specifies whether displays output values in Metric or English formats. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER metric(0), english(1)  

tlpCoolingBeepOnKey 1.3.6.1.4.1.850.1.1.3.5.5.1.1.5
Specifies whether a beep is emitted when a key is pressed on the unit's display panel. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noBeep(0), beepOn(1)  

tlpCoolingInputContactType 1.3.6.1.4.1.850.1.1.3.5.5.1.1.6
The input contact type. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normallyClosed(0), normallyOpen(1)  

tlpCoolingOutputContactType 1.3.6.1.4.1.850.1.1.3.5.5.1.1.7
The output contact type. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normallyClosed(0), normallyOpen(1)  

tlpCoolingOutputRelaySource 1.3.6.1.4.1.850.1.1.3.5.5.1.1.8
The alarm level that causes the output relay to activate. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), allAlarmsAndWarnings(1), criticalAlarmsOnly(2)  

tlpCoolingOutputRelayDefault 1.3.6.1.4.1.850.1.1.3.5.5.1.1.9
Type of contact to make when output relay is activated. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normallyClosed(0), normallyOpen(1)  

tlpCoolingOffOnInputContact 1.3.6.1.4.1.850.1.1.3.5.5.1.1.10
Indicates if the unit should stop cooling when input contact is activated. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER turnOff(0), alarmOnly(1)  

tlpCoolingOffOnLeak 1.3.6.1.4.1.850.1.1.3.5.5.1.1.11
Indicates if the unit should stop cooling when leak input is activated. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER turnOff(0), alarmOnly(1)  

tlpCoolingWaterLeakContactType 1.3.6.1.4.1.850.1.1.3.5.5.1.1.12
The water leak contact type. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normallyClosed(0), normallyOpen(1)  

tlpCoolingAirFilterInterval 1.3.6.1.4.1.850.1.1.3.5.5.1.1.13
The number of weeks before the air filter needs to be changed. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpCoolingAirFilterAlarm 1.3.6.1.4.1.850.1.1.3.5.5.1.1.14
When enabled, an alarm should occur when the maximum number of air filter run hours has been exceeded. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

tlpCoolingMaxAirFilterRunHours 1.3.6.1.4.1.850.1.1.3.5.5.1.1.15
The maximum interval for air filter run hours before warning is annunciated. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpCoolingStartTimer 1.3.6.1.4.1.850.1.1.3.5.5.1.1.16
The unit will start operate after the specified timer elapsed. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpCoolingStopTimer 1.3.6.1.4.1.850.1.1.3.5.5.1.1.17
The unit will switch to standby mode after the specified timer elapsed. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpCoolingEnergyMode 1.3.6.1.4.1.850.1.1.3.5.5.1.1.18
This option enables or disables the energy saving mode. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normalCooling(0), energySaving(1)  

tlpCoolingDefrostMode 1.3.6.1.4.1.850.1.1.3.5.5.1.1.19
This option enables or disables the defrost mode. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

tlpCoolingRemoteTemperatureSensor 1.3.6.1.4.1.850.1.1.3.5.5.1.1.20
This option enables or disables the remote temperature sensor. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

tlpCoolingDehumidifyingMode 1.3.6.1.4.1.850.1.1.3.5.5.1.1.21
This option enables or disables the dehumidifying mode. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

tlpCoolingFanAlwaysOn 1.3.6.1.4.1.850.1.1.3.5.5.1.1.22
This option enables or disables the fan always on. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

tlpCoolingQuietMode 1.3.6.1.4.1.850.1.1.3.5.5.1.1.23
This option enables or disables the quiet mode. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

tlpCoolingHotGasBypass 1.3.6.1.4.1.850.1.1.3.5.5.1.1.24
This option enables or disables the hot gas bypass. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

tlpCoolingAutoFanSpeed 1.3.6.1.4.1.850.1.1.3.5.5.1.1.25
This option enables or disables the auto fan speed. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

tlpCoolingConfigTemperatureFahrenheitTable 1.3.6.1.4.1.850.1.1.3.5.5.2
The configuration details for each each cooling device in device table. This is a sparse dependent table, and will contain some subset of devices that are cooling device. Not all options are available on all cooling devices.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpCoolingConfigTemperatureFahrenheitEntry

tlpCoolingConfigTemperatureFahrenheitEntry 1.3.6.1.4.1.850.1.1.3.5.5.2.1
An entry configuration details for a particular cooling device.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpCoolingConfigTemperatureFahrenheitEntry  

tlpCoolingSetPointDegF 1.3.6.1.4.1.850.1.1.3.5.5.2.1.1
The set point temperature the unit will control the temperature in tenths degrees Fahrenheit. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tlpCoolingSupplyAirHighLimitDegF 1.3.6.1.4.1.850.1.1.3.5.5.2.1.2
Maximum allowed supply air temperature in tenths degrees Fahrenheit before firing an alarm. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tlpCoolingSupplyAirLowLimitDegF 1.3.6.1.4.1.850.1.1.3.5.5.2.1.3
Minimum allowed supply air temperature in tenths degrees Fahrenheit before firing an alarm. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tlpCoolingMaxDeviationLimitDegF 1.3.6.1.4.1.850.1.1.3.5.5.2.1.4
Maximum allowed air temperature deviation from set temperature before firing an alarm. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tlpCoolingReturnAirHighLimitDegF 1.3.6.1.4.1.850.1.1.3.5.5.2.1.5
Maximum allowed supply air temperature in tenths degrees Fahrenheit before firing an alarm. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tlpCoolingReturnAirLowLimitDegF 1.3.6.1.4.1.850.1.1.3.5.5.2.1.6
Minimum allowed supply air temperature in tenths degrees Fahrenheit before firing an alarm. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tlpCoolingRemoteSetPointDegF 1.3.6.1.4.1.850.1.1.3.5.5.2.1.7
The remote set point temperature the unit will control the temperature in tenths degrees Fahrenheit. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tlpCoolingConfigTemperatureCelsiusTable 1.3.6.1.4.1.850.1.1.3.5.5.3
The configuration details for each cooling device in device table. This is a sparse dependent table, and will contain some subset of devices that are cooling device. Not all options are available on all cooling devices.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpCoolingConfigTemperatureCelsiusEntry

tlpCoolingConfigTemperatureCelsiusEntry 1.3.6.1.4.1.850.1.1.3.5.5.3.1
An entry configuration details for a particular cooling device.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpCoolingConfigTemperatureCelsiusEntry  

tlpCoolingSetPointDegC 1.3.6.1.4.1.850.1.1.3.5.5.3.1.1
The set point temperature the unit will control the temperature in tenths degrees Celsius. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tlpCoolingSupplyAirHighLimitDegC 1.3.6.1.4.1.850.1.1.3.5.5.3.1.2
Maximum allowed supply air temperature in tenths degrees Celsius before firing an alarm. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tlpCoolingSupplyAirLowLimitDegC 1.3.6.1.4.1.850.1.1.3.5.5.3.1.3
Minimum allowed supply air temperature in tenths degrees Celsius before firing an alarm. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tlpCoolingMaxDeviationLimitDegC 1.3.6.1.4.1.850.1.1.3.5.5.3.1.4
Maximum allowed air temperature deviation from set temperature before firing an alarm. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tlpCoolingReturnAirHighLimitDegC 1.3.6.1.4.1.850.1.1.3.5.5.3.1.5
Maximum allowed return air temperature in tenths degrees Celsius before firing an alarm. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tlpCoolingReturnAirLowLimitDegC 1.3.6.1.4.1.850.1.1.3.5.5.3.1.6
Minimum allowed return air temperature in tenths degrees Celsius before firing an alarm. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tlpCoolingRemoteSetPointDegC 1.3.6.1.4.1.850.1.1.3.5.5.3.1.7
The remote set point temperature the unit will control the temperature in tenths degrees Celsius. If not supported, this value will always return ERROR_NO_SUCH_NAME.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tlpKvmIdentNumKvm 1.3.6.1.4.1.850.1.1.3.6.1.1
The number of kvm devices that this agent is currently managing.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpRackTrackIdentNumRackTrack 1.3.6.1.4.1.850.1.1.3.7.1.1
The number of rack track devices that this agent is currently managing.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpSwitchIdentNumSwitch 1.3.6.1.4.1.850.1.1.3.8.1.1
The number of switch devices that this agent is currently managing.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAgentType 1.3.6.1.4.1.850.1.2.1.1.1
The type of PowerAlert engine providing this data.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), pal(1), pansa(2), delta(3), sinetica(4), netos6(5), netos7(6), panms(7), nmc5(8)  

tlpAgentVersion 1.3.6.1.4.1.850.1.2.1.1.2
The version of the agent software.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

tlpAgentDriverVersion 1.3.6.1.4.1.850.1.2.1.1.3
The driver version of the agent software.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

tlpAgentMAC 1.3.6.1.4.1.850.1.2.1.1.4
The MAC Address of the agent.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

tlpAgentSerialNum 1.3.6.1.4.1.850.1.2.1.1.5
Serial number of the web card providing the agent data. This value is only supported by a web card agent. PowerAlert for PC (PAL) agents do not support this value and will return ERROR_NO_SUCH_NAME.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

tlpAgentUuid 1.3.6.1.4.1.850.1.2.1.1.6
Universally unique identifier for this host in the form 8-4-4-4-12 for a total of 36 characters (32 alphanumeric characters and four hyphens). For example: 550e8400-e29b-41d4-a716-446655440000.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

tlpAgentAttributesSupports 1.3.6.1.4.1.850.1.2.1.2.1
OBJECT IDENTIFIER    

tlpAgentAttributesSupportsHTTP 1.3.6.1.4.1.850.1.2.1.2.1.1
Indicates whether the agent supports HTTP connections.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpAgentAttributesSupportsHTTPS 1.3.6.1.4.1.850.1.2.1.2.1.2
Indicates whether the agent supports HTTPS connections.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpAgentAttributesSupportsFTP 1.3.6.1.4.1.850.1.2.1.2.1.3
Indicates whether the agent supports FTP connections.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpAgentAttributesSupportsTelnetMenu 1.3.6.1.4.1.850.1.2.1.2.1.4
Indicates whether the agent supports Telnet menu connections.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpAgentAttributesSupportsTelnetCLI 1.3.6.1.4.1.850.1.2.1.2.1.5
Indicates whether the agent supports Telnet CLI connections.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpAgentAttributesSupportsSSHMenu 1.3.6.1.4.1.850.1.2.1.2.1.6
Indicates whether the agent supports SSH menu connections.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpAgentAttributesSupportsSSHCLI 1.3.6.1.4.1.850.1.2.1.2.1.7
Indicates whether the agent supports SSH CLI connections.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpAgentAttributesSupportsSNMP 1.3.6.1.4.1.850.1.2.1.2.1.8
Indicates whether the agent supports SNMP connections.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpAgentAttributesSupportsSNMPTrap 1.3.6.1.4.1.850.1.2.1.2.1.9
Indicates whether the agent supports listening for SNMP traps. This is only applicable for network monitoring applications, PowerAlert Shutdown Agent for an example, that connect to a web card or PowerAlert Local and listen for outbound traps. As such, this value is not supported and will always return 2(false) for a web card or PowerAlert Local.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpAgentAttributesAutostart 1.3.6.1.4.1.850.1.2.1.2.2
OBJECT IDENTIFIER    

tlpAgentAttributesAutostartHTTP 1.3.6.1.4.1.850.1.2.1.2.2.1
Indicates whether the agent autostarts HTTP services.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpAgentAttributesAutostartHTTPS 1.3.6.1.4.1.850.1.2.1.2.2.2
Indicates whether the agent autostarts HTTPS services.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpAgentAttributesAutostartFTP 1.3.6.1.4.1.850.1.2.1.2.2.3
Indicates whether the agent autostarts FTP services.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpAgentAttributesAutostartTelnetMenu 1.3.6.1.4.1.850.1.2.1.2.2.4
Indicates whether the agent autostarts Telnet menu services.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpAgentAttributesAutostartTelnetCLI 1.3.6.1.4.1.850.1.2.1.2.2.5
Indicates whether the agent autostarts Telnet CLI services.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpAgentAttributesAutostartSSHMenu 1.3.6.1.4.1.850.1.2.1.2.2.6
Indicates whether the agent autostarts SSH menu services.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpAgentAttributesAutostartSSHCLI 1.3.6.1.4.1.850.1.2.1.2.2.7
Indicates whether the agent autostarts SSH CLI services.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpAgentAttributesAutostartSNMP 1.3.6.1.4.1.850.1.2.1.2.2.8
Indicates whether the agent autostarts SNMP services.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpAgentAttributesSnmp 1.3.6.1.4.1.850.1.2.1.2.3
OBJECT IDENTIFIER    

tlpAgentAttributesSNMPv1Enabled 1.3.6.1.4.1.850.1.2.1.2.3.1
Indicates whether the agent will allow SNMPv1 connections.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpAgentAttributesSNMPv2cEnabled 1.3.6.1.4.1.850.1.2.1.2.3.2
Indicates whether the agent will allow SNMPv2c connections.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpAgentAttributesSNMPv3Enabled 1.3.6.1.4.1.850.1.2.1.2.3.3
Indicates whether the agent will allow SNMPv3 connections.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tlpAgentAttributesPorts 1.3.6.1.4.1.850.1.2.1.2.4
OBJECT IDENTIFIER    

tlpAgentAttributesHTTPPort 1.3.6.1.4.1.850.1.2.1.2.4.1
The port used for HTTP communications.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAgentAttributesHTTPSPort 1.3.6.1.4.1.850.1.2.1.2.4.2
The port used for HTTPS communications.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAgentAttributesFTPPort 1.3.6.1.4.1.850.1.2.1.2.4.3
The port used for FTP communications.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAgentAttributesTelnetMenuPort 1.3.6.1.4.1.850.1.2.1.2.4.4
The port used for Telnet Menu communications.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAgentAttributesTelnetCLIPort 1.3.6.1.4.1.850.1.2.1.2.4.5
The port used for Telnet CLI communications.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAgentAttributesSSHMenuPort 1.3.6.1.4.1.850.1.2.1.2.4.6
The port used for SSH Menu communications.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAgentAttributesSSHCLIPort 1.3.6.1.4.1.850.1.2.1.2.4.7
The port used for SSH CLI communications.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAgentAttributesSNMPPort 1.3.6.1.4.1.850.1.2.1.2.4.8
The port used for SNMP communications.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAgentAttributesSNMPTrapPort 1.3.6.1.4.1.850.1.2.1.2.4.9
The port used for SNMP trap and notifications.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAgentConfigRemoteRegistration 1.3.6.1.4.1.850.1.2.2.1.1
Registers an SNMP contact's IP address and the port on which the contact is listening for SNMP traps. Setting this value is used to CREATE a table entry in a non-standard way. Getting this value will return a string INADDR_ANY and any port number. The port number should always be included. When unregistering an SNMP contact, the requester's IP address should be provided with a port number of 0. When setting or unsetting this OID, the IP address string should never be 0 nor should it be empty. The registration uses its default community string to register each contact. To use a community other than the default, then it must be appended to the end of the string delimited with a comma. The address should be of the format 0.0.0.0:00000 for IPv4. If IPv6 is supported, use the bracket-enclosed format given in IETF RFC 2732 Section 2, with the following examples: [FEDC:BA98:7654:3210:FEDC:BA98:7654:3210]:80 [1080:0:0:0:8:800:200C:417A]:162 [3ffe:2a00:100:7031::1]:162 [1080::8:800:200C:417A]:162,myCommunity [::192.9.5.5]:162,myCommunity [::FFFF:129.144.52.38]:80 [2010:836B:4179::836B:4179]:162
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

tlpAgentConfigCurrentTime 1.3.6.1.4.1.850.1.2.2.1.2
The current date and time of the system.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

tlpAgentNumEmailContacts 1.3.6.1.4.1.850.1.2.3.1.1
The number of email contacts currently defined in the agent.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAgentEmailContactTable 1.3.6.1.4.1.850.1.2.3.1.2
A list of email contact entries. The number of entries is given by the value of tlpAgentNumEmailContacts.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpAgentEmailContactEntry

tlpAgentEmailContactEntry 1.3.6.1.4.1.850.1.2.3.1.2.1
An entry containing the details of an email contact.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpAgentEmailContactEntry  

tlpAgentEmailContactIndex 1.3.6.1.4.1.850.1.2.3.1.2.1.1
The table row index for the email contact.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAgentEmailContactRowStatus 1.3.6.1.4.1.850.1.2.3.1.2.1.2
Row status for the tlpAgentEmailContactTable.
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

tlpAgentEmailContactName 1.3.6.1.4.1.850.1.2.3.1.2.1.3
The name of the email contact.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

tlpAgentEmailContactAddress 1.3.6.1.4.1.850.1.2.3.1.2.1.4
The address of the email contact.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

tlpAgentNumSnmpContacts 1.3.6.1.4.1.850.1.2.3.2.1
The number of SNMP contacts currently defined in the agent.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAgentSnmpContactTable 1.3.6.1.4.1.850.1.2.3.2.2
A list of SNMP contact entries. The number of entries is given by the value of tlpAgentNumSnmpContacts.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpAgentSnmpContactEntry

tlpAgentSnmpContactEntry 1.3.6.1.4.1.850.1.2.3.2.2.1
An entry containing the details of an SNMP contact.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpAgentSnmpContactEntry  

tlpAgentSnmpContactIndex 1.3.6.1.4.1.850.1.2.3.2.2.1.1
The table row index for the SNMP contact.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAgentSnmpContactRowStatus 1.3.6.1.4.1.850.1.2.3.2.2.1.2
Row status for the tlpAgentSnmpContactTable.
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

tlpAgentSnmpContactName 1.3.6.1.4.1.850.1.2.3.2.2.1.3
The name of the SNMP contact.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

tlpAgentSnmpContactIpAddress 1.3.6.1.4.1.850.1.2.3.2.2.1.4
The IP address of the SNMP contact.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

tlpAgentSnmpContactPort 1.3.6.1.4.1.850.1.2.3.2.2.1.5
The port of the SNMP contact.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tlpAgentSnmpContactSnmpVersion 1.3.6.1.4.1.850.1.2.3.2.2.1.6
The SNMP contact version to use for sending traps.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER snmpv1(1), snmpv2c(2), snmpv3(3)  

tlpAgentSnmpContactSecurityName 1.3.6.1.4.1.850.1.2.3.2.2.1.7
The security name for the SNMP contact.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

tlpAgentSnmpContactPrivPassword 1.3.6.1.4.1.850.1.2.3.2.2.1.8
The privacy password to use for sending V3 traps to the SNMP contact.
Status: obsolete Access: read-write
OBJECT-TYPE    
  DisplayString  

tlpAgentSnmpContactAuthPassword 1.3.6.1.4.1.850.1.2.3.2.2.1.9
The authentication password to use for sending V3 traps to the SNMP contact.
Status: obsolete Access: read-write
OBJECT-TYPE    
  DisplayString  

tlpAlarmsPresent 1.3.6.1.4.1.850.1.3.1
The present number of active alarm conditions.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAlarmTable 1.3.6.1.4.1.850.1.3.2
A list of alarm conditions for all devices managed by this agent. This table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect or conditions not acknowledged. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains (becomes inactive and is acknowledged). The agent creates the first row with tlpAlarmId equal to 1, and increments the value of tlpAlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of tlpAlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse (e.g., containing entries for rows 95, 100, 101, and 203) and the entries should not be assumed to be in chronological order because tlpAlarmId might have wrapped. The number of rows in the table at any given time is reflected by the value of tlpAlarmsPresent.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpDeviceAlarmEntry

tlpAlarmEntry 1.3.6.1.4.1.850.1.3.2.1
An entry containing information application to a particular alarm.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpDeviceAlarmEntry  

tlpAlarmId 1.3.6.1.4.1.850.1.3.2.1.1
A unique identifier for an alarm condition. This value will remain constant for the duration of the alarm condition.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAlarmDescr 1.3.6.1.4.1.850.1.3.2.1.2
A reference of the alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description for the alarm condition. The object referenced will be a well known alarm object associated with the device on which the alarm condition is active.
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

tlpAlarmTime 1.3.6.1.4.1.850.1.3.2.1.3
The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of tlpAlarmsTime shall equal 0.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

tlpAlarmTableRef 1.3.6.1.4.1.850.1.3.2.1.4
This value references the OID of a table object applicable to the alarm condition. This, in conjunction with the table row as defined by tlpAlarmTableRowRef, specifies the object/row within this table to which the alarm condition applies. Example 1 -- The following sample values will be returned for a UPS on battery: tlpAlarmId 28 tlpAlarmDescr tlpUpsAlarmOnBattery tlpAlarmTime 12345678 tlpAlarmTableRef tlpDeviceTable tlpAlarmTableRowRef tlpDeviceIndex.2 tlpAlarmDetail On Battery tlpAlarmType warning tlpAlarmState active tlpAlarmAcknowledged notAcknowledged In the above example, tlpAlarmTableRef references the device table and tlpAlarmTableRowRef references the 2nd managed device in that table. Example 2 -- The following sample values will be returned for a PDU with a load turned off: tlpAlarmId 46 tlpAlarmDescr tlpPduAlarmLoadOff tlpAlarmTime 12345678 tlpAlarmTableRef tlpPduOutletTable tlpAlarmTableRowRef tlpOutletIndex.1.4 tlpAlarmDetail Load Off tlpAlarmType warning tlpAlarmState active tlpAlarmAcknowledged acknowledged In the above example, tlpAlarmTableRef references the pdu outlet table and tlpAlarmTableRowRef references the 4th outlet on the 1st managed device.
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

tlpAlarmTableRowRef 1.3.6.1.4.1.850.1.3.2.1.5
This value is used in conjunction with tlpAlarmTableRef to define the object associated with this alarm condition. See the description of tlpAlarmTableRef for more information.
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

tlpAlarmDetail 1.3.6.1.4.1.850.1.3.2.1.6
A textual description of the alarm condition.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

tlpAlarmType 1.3.6.1.4.1.850.1.3.2.1.7
The category/group of this alarm.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER critical(1), warning(2), info(3), status(4), offline(5), custom(6)  

tlpAlarmState 1.3.6.1.4.1.850.1.3.2.1.8
The current state of this alarm condition. An active(1) alarm is a condition that currently exists. An inactive(2) alarm is a condition that no longer exists because the alarm either cleared or was resolved. Each alarm condition must be cleared and acknowledged before it is removed from this table (see tlpAlarmAcknowledged).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER active(1), inactive(2)  

tlpAlarmAcknowledged 1.3.6.1.4.1.850.1.3.2.1.9
Denotes whether the alarm condition has been acknowledged. The agent will return notAcknowledged(1) if the condition has not been acknowledged, or acknowledged(2) when acknowledged. Writing the value acknowledged(2) for an alarm acknowledges the alarm condition. Each alarm condition must be cleared and acknowledged before it is removed from this table; therefore, even if acknowledged, the alarm will remain in this table until the alarm becomes inactive as denoted by tlpAlarmState.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notAcknowledged(1), acknowledged(2)  

tlpAlarmCommunicationsLost 1.3.6.1.4.1.850.1.3.3.2.1
A problem has been encountered in the communications between the agent and the device.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAlarmUserDefined 1.3.6.1.4.1.850.1.3.3.2.2
OBJECT IDENTIFIER    

tlpAlarmUserDefined01 1.3.6.1.4.1.850.1.3.3.2.2.1
User-defined event 1 is in alarm.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAlarmUserDefined02 1.3.6.1.4.1.850.1.3.3.2.2.2
User-defined event 2 is in alarm.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAlarmUserDefined03 1.3.6.1.4.1.850.1.3.3.2.2.3
User-defined event 3 is in alarm.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAlarmUserDefined04 1.3.6.1.4.1.850.1.3.3.2.2.4
User-defined event 4 is in alarm.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAlarmUserDefined05 1.3.6.1.4.1.850.1.3.3.2.2.5
User-defined event 5 is in alarm.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAlarmUserDefined06 1.3.6.1.4.1.850.1.3.3.2.2.6
User-defined event 6 is in alarm.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAlarmUserDefined07 1.3.6.1.4.1.850.1.3.3.2.2.7
User-defined event 7 is in alarm.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAlarmUserDefined08 1.3.6.1.4.1.850.1.3.3.2.2.8
User-defined event 8 is in alarm.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAlarmUserDefined09 1.3.6.1.4.1.850.1.3.3.2.2.9
User-defined event 9 is in alarm.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAlarmInternalFirmwareError 1.3.6.1.4.1.850.1.3.3.2.3
A problem has been encountered with the device firmware.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmBatteryBad 1.3.6.1.4.1.850.1.3.3.3.1
One or more batteries have been determined to require replacement.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmOnBattery 1.3.6.1.4.1.850.1.3.3.3.2
The UPS is drawing power from the batteries.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLowBattery 1.3.6.1.4.1.850.1.3.3.3.3
The remaining battery charge is less than or equal to the percentage of capacity warning specified by tlpUpsConfigBatteryCapacityThreshold.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmDepletedBattery 1.3.6.1.4.1.850.1.3.3.3.4
The UPS will be unable to sustain the present load when and if the utility power is lost.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmTempBad 1.3.6.1.4.1.850.1.3.3.3.5
A temperature is out of tolerance.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmInputBad 1.3.6.1.4.1.850.1.3.3.3.6
An input condition is out of tolerance.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmOutputBad 1.3.6.1.4.1.850.1.3.3.3.7
An output condition (other than OutputOverload) is out of tolerance.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmOutputOverload 1.3.6.1.4.1.850.1.3.3.3.8
The output load exceeds the UPS output capacity.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmOnBypass 1.3.6.1.4.1.850.1.3.3.3.9
The Bypass is presently engaged on the UPS.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmBypassBad 1.3.6.1.4.1.850.1.3.3.3.10
The Bypass is out of tolerance.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmOutputOffAsRequested 1.3.6.1.4.1.850.1.3.3.3.11
The UPS has shutdown as requested, i.e., the output is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmUpsOffAsRequested 1.3.6.1.4.1.850.1.3.3.3.12
The entire UPS has shutdown as commanded.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmChargerFailed 1.3.6.1.4.1.850.1.3.3.3.13
An uncorrected problem has been detected within the UPS charger subsystem.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmUpsOutputOff 1.3.6.1.4.1.850.1.3.3.3.14
The output of the UPS is in the off state.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmUpsSystemOff 1.3.6.1.4.1.850.1.3.3.3.15
The UPS system is in the off state.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmFanFailure 1.3.6.1.4.1.850.1.3.3.3.16
The failure of one or more fans in the UPS has been detected.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmFuseFailure 1.3.6.1.4.1.850.1.3.3.3.17
The failure of one or more fuses has been detected.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmGeneralFault 1.3.6.1.4.1.850.1.3.3.3.18
A general fault in the UPS has been detected.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmDiagnosticTestFailed 1.3.6.1.4.1.850.1.3.3.3.19
The result of the last diagnostic test indicates a failure.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmAwaitingPower 1.3.6.1.4.1.850.1.3.3.3.20
The UPS output is off and the UPS is awaiting the return of input power.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmShutdownPending 1.3.6.1.4.1.850.1.3.3.3.21
A tlpUpsShutdownAfterDelay countdown is underway.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmShutdownImminent 1.3.6.1.4.1.850.1.3.3.3.22
The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadLevelAboveThreshold 1.3.6.1.4.1.850.1.3.3.3.23
OBJECT IDENTIFIER    

tlpUpsAlarmLoadLevelAboveThresholdTotal 1.3.6.1.4.1.850.1.3.3.3.23.1
The total load level is above the designated threshold.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadLevelAboveThresholdPhase1 1.3.6.1.4.1.850.1.3.3.3.23.2
The load level on phase 1 exceeds load limits.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadLevelAboveThresholdPhase2 1.3.6.1.4.1.850.1.3.3.3.23.3
The load level on phase 2 exceeds load limits.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadLevelAboveThresholdPhase3 1.3.6.1.4.1.850.1.3.3.3.23.4
The load level on phase 3 exceeds load limits.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmOutputCurrentChanged 1.3.6.1.4.1.850.1.3.3.3.24
The output current changed from its last known value.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmBatteryAgeAboveThreshold 1.3.6.1.4.1.850.1.3.3.3.25
One or more batteries have been determined to require replacement.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff 1.3.6.1.4.1.850.1.3.3.3.26
OBJECT IDENTIFIER    

tlpUpsAlarmLoadOff01 1.3.6.1.4.1.850.1.3.3.3.26.1
Load 1 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff02 1.3.6.1.4.1.850.1.3.3.3.26.2
Load 2 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff03 1.3.6.1.4.1.850.1.3.3.3.26.3
Load 3 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff04 1.3.6.1.4.1.850.1.3.3.3.26.4
Load 4 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff05 1.3.6.1.4.1.850.1.3.3.3.26.5
Load 5 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff06 1.3.6.1.4.1.850.1.3.3.3.26.6
Load 6 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff07 1.3.6.1.4.1.850.1.3.3.3.26.7
Load 7 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff08 1.3.6.1.4.1.850.1.3.3.3.26.8
Load 8 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff09 1.3.6.1.4.1.850.1.3.3.3.26.9
Load 9 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff10 1.3.6.1.4.1.850.1.3.3.3.26.10
Load 10 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff11 1.3.6.1.4.1.850.1.3.3.3.26.11
Load 11 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff12 1.3.6.1.4.1.850.1.3.3.3.26.12
Load 12 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff13 1.3.6.1.4.1.850.1.3.3.3.26.13
Load 13 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff14 1.3.6.1.4.1.850.1.3.3.3.26.14
Load 14 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff15 1.3.6.1.4.1.850.1.3.3.3.26.15
Load 15 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff16 1.3.6.1.4.1.850.1.3.3.3.26.16
Load 16 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff17 1.3.6.1.4.1.850.1.3.3.3.26.17
Load 17 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff18 1.3.6.1.4.1.850.1.3.3.3.26.18
Load 18 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff19 1.3.6.1.4.1.850.1.3.3.3.26.19
Load 19 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff20 1.3.6.1.4.1.850.1.3.3.3.26.20
Load 20 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff21 1.3.6.1.4.1.850.1.3.3.3.26.21
Load 21 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff22 1.3.6.1.4.1.850.1.3.3.3.26.22
Load 22 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff23 1.3.6.1.4.1.850.1.3.3.3.26.23
Load 23 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff24 1.3.6.1.4.1.850.1.3.3.3.26.24
Load 24 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff25 1.3.6.1.4.1.850.1.3.3.3.26.25
Load 25 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff26 1.3.6.1.4.1.850.1.3.3.3.26.26
Load 26 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff27 1.3.6.1.4.1.850.1.3.3.3.26.27
Load 27 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff28 1.3.6.1.4.1.850.1.3.3.3.26.28
Load 28 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff29 1.3.6.1.4.1.850.1.3.3.3.26.29
Load 29 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff30 1.3.6.1.4.1.850.1.3.3.3.26.30
Load 30 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff31 1.3.6.1.4.1.850.1.3.3.3.26.31
Load 31 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff32 1.3.6.1.4.1.850.1.3.3.3.26.32
Load 32 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff33 1.3.6.1.4.1.850.1.3.3.3.26.33
Load 33 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff34 1.3.6.1.4.1.850.1.3.3.3.26.34
Load 34 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff35 1.3.6.1.4.1.850.1.3.3.3.26.35
Load 35 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff36 1.3.6.1.4.1.850.1.3.3.3.26.36
Load 36 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff37 1.3.6.1.4.1.850.1.3.3.3.26.37
Load 37 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff38 1.3.6.1.4.1.850.1.3.3.3.26.38
Load 38 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff39 1.3.6.1.4.1.850.1.3.3.3.26.39
Load 39 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadOff40 1.3.6.1.4.1.850.1.3.3.3.26.40
Load 40 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmCurrentAboveThreshold 1.3.6.1.4.1.850.1.3.3.3.27
OBJECT IDENTIFIER    

tlpUpsAlarmCurrentAboveThreshold1 1.3.6.1.4.1.850.1.3.3.3.27.1
The output current on phase 1 exceeds load limits.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmCurrentAboveThreshold2 1.3.6.1.4.1.850.1.3.3.3.27.2
The output current on phase 2 exceeds load limits.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmCurrentAboveThreshold3 1.3.6.1.4.1.850.1.3.3.3.27.3
The output current on phase 3 exceeds load limits.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmRuntimeBelowWarningLevel 1.3.6.1.4.1.850.1.3.3.3.28
The battery seconds remaining is below warning level.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmBusStartVoltageLow 1.3.6.1.4.1.850.1.3.3.3.29
The inverter start up bus voltage is too low.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmBusOverVoltage 1.3.6.1.4.1.850.1.3.3.3.30
The inverter bus voltage is too high.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmBusUnderVoltage 1.3.6.1.4.1.850.1.3.3.3.31
The inverter bus voltage is too low.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmBusVoltageUnbalanced 1.3.6.1.4.1.850.1.3.3.3.32
The inverter bus voltage is not balanced.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmInverterSoftStartBad 1.3.6.1.4.1.850.1.3.3.3.33
The inverter bus voltage cannot reach desired voltage within a specified duration.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmInverterOverVoltage 1.3.6.1.4.1.850.1.3.3.3.34
The inverter voltage is too high.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmInverterUnderVoltage 1.3.6.1.4.1.850.1.3.3.3.35
The inverter voltage is too low.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmInverterCircuitBad 1.3.6.1.4.1.850.1.3.3.3.36
The inverter output is shorted.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmBatteryOverVoltage 1.3.6.1.4.1.850.1.3.3.3.37
The battery voltage is too high.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmBatteryUnderVoltage 1.3.6.1.4.1.850.1.3.3.3.38
The battery voltage is too low.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmSiteWiringFault 1.3.6.1.4.1.850.1.3.3.3.39
The utility input wiring is faulty.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmOverTemperatureProtection 1.3.6.1.4.1.850.1.3.3.3.40
The over temperature protection is activated.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmOverCharged 1.3.6.1.4.1.850.1.3.3.3.41
The UPS is over charged.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmEPOActive 1.3.6.1.4.1.850.1.3.3.3.42
The EPO is currently activated.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmBypassFrequencyBad 1.3.6.1.4.1.850.1.3.3.3.43
The bypass frequency is out of tolerance.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmExternalSmartBatteryAgeAboveThreshold 1.3.6.1.4.1.850.1.3.3.3.44
One or more external smart batteries have been determined to require replacement.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmExternalNonSmartBatteryAgeAboveThreshold 1.3.6.1.4.1.850.1.3.3.3.45
One or more external non-smart batteries have been determined to require replacement.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmSmartBatteryCommLost 1.3.6.1.4.1.850.1.3.3.3.46
Communications with the smart batteries was lost.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpUpsAlarmLoadsNotAllOn 1.3.6.1.4.1.850.1.3.3.3.47
One of more loads are not on.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadLevelAboveThreshold 1.3.6.1.4.1.850.1.3.3.4.1
The load level is above the designated threshold.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmInputBad 1.3.6.1.4.1.850.1.3.3.4.2
An input condition is out of tolerance.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmOutputBad 1.3.6.1.4.1.850.1.3.3.4.3
An output condition (other than OutputOverload) is out of tolerance.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmOutputOverload 1.3.6.1.4.1.850.1.3.3.4.4
The output load exceeds the pdu output capacity.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmOutputOff 1.3.6.1.4.1.850.1.3.3.4.5
The output of the pdu is in the off state.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff 1.3.6.1.4.1.850.1.3.3.4.6
OBJECT IDENTIFIER    

tlpPduAlarmLoadOff01 1.3.6.1.4.1.850.1.3.3.4.6.1
Load 1 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff02 1.3.6.1.4.1.850.1.3.3.4.6.2
Load 2 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff03 1.3.6.1.4.1.850.1.3.3.4.6.3
Load 3 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff04 1.3.6.1.4.1.850.1.3.3.4.6.4
Load 4 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff05 1.3.6.1.4.1.850.1.3.3.4.6.5
Load 5 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff06 1.3.6.1.4.1.850.1.3.3.4.6.6
Load 6 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff07 1.3.6.1.4.1.850.1.3.3.4.6.7
Load 7 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff08 1.3.6.1.4.1.850.1.3.3.4.6.8
Load 8 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff09 1.3.6.1.4.1.850.1.3.3.4.6.9
Load 9 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff10 1.3.6.1.4.1.850.1.3.3.4.6.10
Load 10 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff11 1.3.6.1.4.1.850.1.3.3.4.6.11
Load 11 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff12 1.3.6.1.4.1.850.1.3.3.4.6.12
Load 12 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff13 1.3.6.1.4.1.850.1.3.3.4.6.13
Load 13 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff14 1.3.6.1.4.1.850.1.3.3.4.6.14
Load 14 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff15 1.3.6.1.4.1.850.1.3.3.4.6.15
Load 15 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff16 1.3.6.1.4.1.850.1.3.3.4.6.16
Load 16 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff17 1.3.6.1.4.1.850.1.3.3.4.6.17
Load 17 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff18 1.3.6.1.4.1.850.1.3.3.4.6.18
Load 18 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff19 1.3.6.1.4.1.850.1.3.3.4.6.19
Load 19 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff20 1.3.6.1.4.1.850.1.3.3.4.6.20
Load 20 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff21 1.3.6.1.4.1.850.1.3.3.4.6.21
Load 21 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff22 1.3.6.1.4.1.850.1.3.3.4.6.22
Load 22 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff23 1.3.6.1.4.1.850.1.3.3.4.6.23
Load 23 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff24 1.3.6.1.4.1.850.1.3.3.4.6.24
Load 24 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff25 1.3.6.1.4.1.850.1.3.3.4.6.25
Load 25 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff26 1.3.6.1.4.1.850.1.3.3.4.6.26
Load 26 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff27 1.3.6.1.4.1.850.1.3.3.4.6.27
Load 27 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff28 1.3.6.1.4.1.850.1.3.3.4.6.28
Load 28 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff29 1.3.6.1.4.1.850.1.3.3.4.6.29
Load 29 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff30 1.3.6.1.4.1.850.1.3.3.4.6.30
Load 30 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff31 1.3.6.1.4.1.850.1.3.3.4.6.31
Load 31 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff32 1.3.6.1.4.1.850.1.3.3.4.6.32
Load 32 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff33 1.3.6.1.4.1.850.1.3.3.4.6.33
Load 33 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff34 1.3.6.1.4.1.850.1.3.3.4.6.34
Load 34 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff35 1.3.6.1.4.1.850.1.3.3.4.6.35
Load 35 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff36 1.3.6.1.4.1.850.1.3.3.4.6.36
Load 36 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff37 1.3.6.1.4.1.850.1.3.3.4.6.37
Load 37 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff38 1.3.6.1.4.1.850.1.3.3.4.6.38
Load 38 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff39 1.3.6.1.4.1.850.1.3.3.4.6.39
Load 39 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadOff40 1.3.6.1.4.1.850.1.3.3.4.6.40
Load 40 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmCircuitBreakerOpen 1.3.6.1.4.1.850.1.3.3.4.7
OBJECT IDENTIFIER    

tlpPduAlarmCircuitBreakerOpen01 1.3.6.1.4.1.850.1.3.3.4.7.1
Circuit breaker 1 is open.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmCircuitBreakerOpen02 1.3.6.1.4.1.850.1.3.3.4.7.2
Circuit breaker 2 is open.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmCircuitBreakerOpen03 1.3.6.1.4.1.850.1.3.3.4.7.3
Circuit breaker 3 is open.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmCircuitBreakerOpen04 1.3.6.1.4.1.850.1.3.3.4.7.4
Circuit breaker 4 is open.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmCircuitBreakerOpen05 1.3.6.1.4.1.850.1.3.3.4.7.5
Circuit breaker 5 is open.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmCircuitBreakerOpen06 1.3.6.1.4.1.850.1.3.3.4.7.6
Circuit breaker 6 is open.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmCurrentAboveThreshold 1.3.6.1.4.1.850.1.3.3.4.8
OBJECT IDENTIFIER    

tlpPduAlarmCurrentAboveThreshold1 1.3.6.1.4.1.850.1.3.3.4.8.1
The output current on phase 1 exceeds load limits.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmCurrentAboveThreshold2 1.3.6.1.4.1.850.1.3.3.4.8.2
The output current on phase 2 exceeds load limits.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmCurrentAboveThreshold3 1.3.6.1.4.1.850.1.3.3.4.8.3
The output current on phase 3 exceeds load limits.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadsNotAllOn 1.3.6.1.4.1.850.1.3.3.4.9
One of more loads are not on.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmLoadLevelBelowThreshold 1.3.6.1.4.1.850.1.3.3.4.10
The load level is below the designated threshold.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmCurrentBelowThreshold 1.3.6.1.4.1.850.1.3.3.4.11
OBJECT IDENTIFIER    

tlpPduAlarmCurrentBelowThreshold1 1.3.6.1.4.1.850.1.3.3.4.11.1
The output current on phase 1 below load limits.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmCurrentBelowThreshold2 1.3.6.1.4.1.850.1.3.3.4.11.2
The output current on phase 2 below load limits.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpPduAlarmCurrentBelowThreshold3 1.3.6.1.4.1.850.1.3.3.4.11.3
The output current on phase 3 below load limits.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpEnvAlarmTemperatureBeyondLimits 1.3.6.1.4.1.850.1.3.3.5.1
The temperature exceeds limits.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpEnvAlarmHumidityBeyondLimits 1.3.6.1.4.1.850.1.3.3.5.2
The humidity exceeds limits.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpEnvAlarmInputContact 1.3.6.1.4.1.850.1.3.3.5.3
OBJECT IDENTIFIER    

tlpEnvAlarmInputContact01 1.3.6.1.4.1.850.1.3.3.5.3.1
Input contact 1 is in alarm.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpEnvAlarmInputContact02 1.3.6.1.4.1.850.1.3.3.5.3.2
Input contact 2 is in alarm.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpEnvAlarmInputContact03 1.3.6.1.4.1.850.1.3.3.5.3.3
Input contact 3 is in alarm.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpEnvAlarmInputContact04 1.3.6.1.4.1.850.1.3.3.5.3.4
Input contact 4 is in alarm.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpEnvAlarmOutputContact 1.3.6.1.4.1.850.1.3.3.5.4
OBJECT IDENTIFIER    

tlpEnvAlarmOutputContact01 1.3.6.1.4.1.850.1.3.3.5.4.1
Output contact 1 is in alarm.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpEnvAlarmOutputContact02 1.3.6.1.4.1.850.1.3.3.5.4.2
Output contact 2 is in alarm.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpEnvAlarmOutputContact03 1.3.6.1.4.1.850.1.3.3.5.4.3
Output contact 3 is in alarm.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpEnvAlarmOutputContact04 1.3.6.1.4.1.850.1.3.3.5.4.4
Output contact 4 is in alarm.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmOutage 1.3.6.1.4.1.850.1.3.3.6.1
OBJECT IDENTIFIER    

tlpAtsAlarmSource1Outage 1.3.6.1.4.1.850.1.3.3.6.1.1
Input on source 1 is not present. For atss with the designation of primary and secondary, this alarm denotes input on the primary source is not present.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmSource2Outage 1.3.6.1.4.1.850.1.3.3.6.1.2
Input on source 2 is not present. For atss with the designation of primary and secondary, this alarm denotes input on the secondary source is not present.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmTemperature 1.3.6.1.4.1.850.1.3.3.6.2
OBJECT IDENTIFIER    

tlpAtsAlarmSystemTemperature 1.3.6.1.4.1.850.1.3.3.6.2.1
The system temperature is out of tolerance.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmSource1Temperature 1.3.6.1.4.1.850.1.3.3.6.2.2
The source 1 temperature is out of tolerance.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmSource2Temperature 1.3.6.1.4.1.850.1.3.3.6.2.3
The source 2 temperature is out of tolerance.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadLevelAboveThreshold 1.3.6.1.4.1.850.1.3.3.6.3
The load level is above the designated threshold.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmInputBad 1.3.6.1.4.1.850.1.3.3.6.4
An input condition is out of tolerance.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmOutputBad 1.3.6.1.4.1.850.1.3.3.6.5
An output condition (other than OutputOverload) is out of tolerance.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmOutputOverload 1.3.6.1.4.1.850.1.3.3.6.6
The output load exceeds the ats output capacity.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmOutputOff 1.3.6.1.4.1.850.1.3.3.6.7
The output of the ats is in the off state.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff 1.3.6.1.4.1.850.1.3.3.6.8
OBJECT IDENTIFIER    

tlpAtsAlarmLoadOff01 1.3.6.1.4.1.850.1.3.3.6.8.1
Load 1 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff02 1.3.6.1.4.1.850.1.3.3.6.8.2
Load 2 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff03 1.3.6.1.4.1.850.1.3.3.6.8.3
Load 3 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff04 1.3.6.1.4.1.850.1.3.3.6.8.4
Load 4 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff05 1.3.6.1.4.1.850.1.3.3.6.8.5
Load 5 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff06 1.3.6.1.4.1.850.1.3.3.6.8.6
Load 6 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff07 1.3.6.1.4.1.850.1.3.3.6.8.7
Load 7 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff08 1.3.6.1.4.1.850.1.3.3.6.8.8
Load 8 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff09 1.3.6.1.4.1.850.1.3.3.6.8.9
Load 9 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff10 1.3.6.1.4.1.850.1.3.3.6.8.10
Load 10 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff11 1.3.6.1.4.1.850.1.3.3.6.8.11
Load 11 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff12 1.3.6.1.4.1.850.1.3.3.6.8.12
Load 12 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff13 1.3.6.1.4.1.850.1.3.3.6.8.13
Load 13 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff14 1.3.6.1.4.1.850.1.3.3.6.8.14
Load 14 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff15 1.3.6.1.4.1.850.1.3.3.6.8.15
Load 15 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff16 1.3.6.1.4.1.850.1.3.3.6.8.16
Load 16 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff17 1.3.6.1.4.1.850.1.3.3.6.8.17
Load 17 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff18 1.3.6.1.4.1.850.1.3.3.6.8.18
Load 18 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff19 1.3.6.1.4.1.850.1.3.3.6.8.19
Load 19 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff20 1.3.6.1.4.1.850.1.3.3.6.8.20
Load 20 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff21 1.3.6.1.4.1.850.1.3.3.6.8.21
Load 21 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff22 1.3.6.1.4.1.850.1.3.3.6.8.22
Load 22 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff23 1.3.6.1.4.1.850.1.3.3.6.8.23
Load 23 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff24 1.3.6.1.4.1.850.1.3.3.6.8.24
Load 24 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff25 1.3.6.1.4.1.850.1.3.3.6.8.25
Load 25 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff26 1.3.6.1.4.1.850.1.3.3.6.8.26
Load 26 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff27 1.3.6.1.4.1.850.1.3.3.6.8.27
Load 27 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff28 1.3.6.1.4.1.850.1.3.3.6.8.28
Load 28 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff29 1.3.6.1.4.1.850.1.3.3.6.8.29
Load 29 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff30 1.3.6.1.4.1.850.1.3.3.6.8.30
Load 30 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff31 1.3.6.1.4.1.850.1.3.3.6.8.31
Load 31 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff32 1.3.6.1.4.1.850.1.3.3.6.8.32
Load 32 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff33 1.3.6.1.4.1.850.1.3.3.6.8.33
Load 33 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff34 1.3.6.1.4.1.850.1.3.3.6.8.34
Load 34 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff35 1.3.6.1.4.1.850.1.3.3.6.8.35
Load 35 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff36 1.3.6.1.4.1.850.1.3.3.6.8.36
Load 36 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff37 1.3.6.1.4.1.850.1.3.3.6.8.37
Load 37 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff38 1.3.6.1.4.1.850.1.3.3.6.8.38
Load 38 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff39 1.3.6.1.4.1.850.1.3.3.6.8.39
Load 39 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadOff40 1.3.6.1.4.1.850.1.3.3.6.8.40
Load 40 is off.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmCircuitBreakerOpen 1.3.6.1.4.1.850.1.3.3.6.9
OBJECT IDENTIFIER    

tlpAtsAlarmCircuitBreakerOpen01 1.3.6.1.4.1.850.1.3.3.6.9.1
Circuit breaker 1 is open.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmCircuitBreakerOpen02 1.3.6.1.4.1.850.1.3.3.6.9.2
Circuit breaker 2 is open.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmCircuitBreakerOpen03 1.3.6.1.4.1.850.1.3.3.6.9.3
Circuit breaker 3 is open.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmCircuitBreakerOpen04 1.3.6.1.4.1.850.1.3.3.6.9.4
Circuit breaker 4 is open.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmCircuitBreakerOpen05 1.3.6.1.4.1.850.1.3.3.6.9.5
Circuit breaker 5 is open.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmCircuitBreakerOpen06 1.3.6.1.4.1.850.1.3.3.6.9.6
Circuit breaker 6 is open.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmCurrentAboveThreshold 1.3.6.1.4.1.850.1.3.3.6.10
OBJECT IDENTIFIER    

tlpAtsAlarmCurrentAboveThresholdA1 1.3.6.1.4.1.850.1.3.3.6.10.1
The output current on input source 1 phase 1 exceeds load limits.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmCurrentAboveThresholdA2 1.3.6.1.4.1.850.1.3.3.6.10.2
The output current on input source 1 phase 2 exceeds load limits.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmCurrentAboveThresholdA3 1.3.6.1.4.1.850.1.3.3.6.10.3
The output current on input source 1 phase 3 exceeds load limits.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmCurrentAboveThresholdB1 1.3.6.1.4.1.850.1.3.3.6.10.4
The output current on input source 2 phase 1 exceeds load limits.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmCurrentAboveThresholdB2 1.3.6.1.4.1.850.1.3.3.6.10.5
The output current on input source 2 phase 2 exceeds load limits.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmCurrentAboveThresholdB3 1.3.6.1.4.1.850.1.3.3.6.10.6
The output current on input source 2 phase 3 exceeds load limits.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadsNotAllOn 1.3.6.1.4.1.850.1.3.3.6.11
One of more loads are not on.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmGeneralFault 1.3.6.1.4.1.850.1.3.3.6.12
A general fault in the ats has been detected.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmVoltage 1.3.6.1.4.1.850.1.3.3.6.13
OBJECT IDENTIFIER    

tlpAtsAlarmOverVoltage 1.3.6.1.4.1.850.1.3.3.6.13.1
The input voltage is out of tolerance.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmSource1OverVoltage 1.3.6.1.4.1.850.1.3.3.6.13.2
The voltage on source 1 is out of tolerance.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmSource2OverVoltage 1.3.6.1.4.1.850.1.3.3.6.13.3
The voltage on source 2 is out of tolerance.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmFrequency 1.3.6.1.4.1.850.1.3.3.6.14
OBJECT IDENTIFIER    

tlpAtsAlarmSource1InvalidFrequency 1.3.6.1.4.1.850.1.3.3.6.14.1
The voltage on source 1 is out of tolerance.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmSource2InvalidFrequency 1.3.6.1.4.1.850.1.3.3.6.14.2
The voltage on source 2 is out of tolerance.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmLoadLevelBelowThreshold 1.3.6.1.4.1.850.1.3.3.6.15
The load level is below the designated threshold.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmCurrentBelowThreshold 1.3.6.1.4.1.850.1.3.3.6.16
OBJECT IDENTIFIER    

tlpAtsAlarmCurrentBelowThresholdA1 1.3.6.1.4.1.850.1.3.3.6.16.1
The output current on input source 1 phase 1 below load limits.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmCurrentBelowThresholdA2 1.3.6.1.4.1.850.1.3.3.6.16.2
The output current on input source 1 phase 2 below load limits.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmCurrentBelowThresholdA3 1.3.6.1.4.1.850.1.3.3.6.16.3
The output current on input source 1 phase 3 below load limits.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmCurrentBelowThresholdB1 1.3.6.1.4.1.850.1.3.3.6.16.4
The output current on input source 2 phase 1 below load limits.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmCurrentBelowThresholdB2 1.3.6.1.4.1.850.1.3.3.6.16.5
The output current on input source 2 phase 2 below load limits.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAtsAlarmCurrentBelowThresholdB3 1.3.6.1.4.1.850.1.3.3.6.16.6
The output current on input source 2 phase 3 below load limits.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmSupplyAirSensorFault 1.3.6.1.4.1.850.1.3.3.7.1
The supply air sensor is in fault.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmReturnAirSensorFault 1.3.6.1.4.1.850.1.3.3.7.2
The return air sensor is in fault.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmCondenserInletAirSensorFault 1.3.6.1.4.1.850.1.3.3.7.3
The condenser inlet air sensor is in fault.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmCondenserOutletAirSensorFault 1.3.6.1.4.1.850.1.3.3.7.4
The condenser outlet air sensor is in fault.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmSuctionTemperatureSensorFault 1.3.6.1.4.1.850.1.3.3.7.5
The suction temperature sensor is in fault.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmEvaporatorTemperatureSensorFault 1.3.6.1.4.1.850.1.3.3.7.6
The evaporator temperature sensor is in fault.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmAirFilterClogged 1.3.6.1.4.1.850.1.3.3.7.7
The air filter is clogged.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmAirFilterRunHoursViolation 1.3.6.1.4.1.850.1.3.3.7.8
The air filter run hours was violated.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmSuctionPressureSensorFault 1.3.6.1.4.1.850.1.3.3.7.9
The suction pressure sensor is in fault.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmInverterCommunicationsFault 1.3.6.1.4.1.850.1.3.3.7.10
The inverter communications is in fault.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmRemoteShutdownViaInputContact 1.3.6.1.4.1.850.1.3.3.7.11
A remote shutdown was triggerd by an input contact.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmCondensatePumpFault 1.3.6.1.4.1.850.1.3.3.7.12
The condensate pump is in fault.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmLowRefrigerantStartupFault 1.3.6.1.4.1.850.1.3.3.7.13
The low refrigerant startup is in fault.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmCondenserFanFault 1.3.6.1.4.1.850.1.3.3.7.14
The condenser fan is in fault.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmCondenserFailure 1.3.6.1.4.1.850.1.3.3.7.15
The condenser has failed.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmEvaporatorCoolingFailure 1.3.6.1.4.1.850.1.3.3.7.16
The evaporator cooling is in fault.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmReturnAirTempHigh 1.3.6.1.4.1.850.1.3.3.7.17
The return air temperature is high.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmSupplyAirTempHigh 1.3.6.1.4.1.850.1.3.3.7.18
The supply air temperature is high.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmEvaporatorFailure 1.3.6.1.4.1.850.1.3.3.7.19
The evaporator has failed.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmEvaporatorFreezeUp 1.3.6.1.4.1.850.1.3.3.7.20
The evaporator is frozen.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmDischargePressureHigh 1.3.6.1.4.1.850.1.3.3.7.21
The discharge pressure is high.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmPressureGaugeFailure 1.3.6.1.4.1.850.1.3.3.7.22
The pressure gauge has failed.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmDischargePressurePersistentHigh 1.3.6.1.4.1.850.1.3.3.7.23
The discharge pressure is persistently high.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmSuctionPressureLowStartFailure 1.3.6.1.4.1.850.1.3.3.7.24
Cannot start due to low suction pressure.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmSuctionPressureLow 1.3.6.1.4.1.850.1.3.3.7.25
The suction pressure is low.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmSuctionPressurePersistentLow 1.3.6.1.4.1.850.1.3.3.7.26
The suction pressure is persistently low.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmStartupLinePressureImbalance 1.3.6.1.4.1.850.1.3.3.7.27
The startup line pressure is in imbalance.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmCompressorFailure 1.3.6.1.4.1.850.1.3.3.7.28
The compressor has failed.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmCurrentLimit 1.3.6.1.4.1.850.1.3.3.7.29
The current is out of range.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmWaterLeak 1.3.6.1.4.1.850.1.3.3.7.30
Water is leaking.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmFanUnderCurrent 1.3.6.1.4.1.850.1.3.3.7.31
The fan is under current.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmFanOverCurrent 1.3.6.1.4.1.850.1.3.3.7.32
The fan is over current.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmDischargePressureSensorFault 1.3.6.1.4.1.850.1.3.3.7.33
The discharge pressure sensor is in fault.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmWaterFull 1.3.6.1.4.1.850.1.3.3.7.34
Water is Full.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmAutoCoolingOn 1.3.6.1.4.1.850.1.3.3.7.35
Automatic cooling was activated to lower the temperature below the remote set point.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmPowerButtonPressed 1.3.6.1.4.1.850.1.3.3.7.36
Power button was pressed on the front panel.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmDisconnectedFromDevice 1.3.6.1.4.1.850.1.3.3.7.37
The device communications is disconnected.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmAmbientTemperatureSensorFault 1.3.6.1.4.1.850.1.3.3.7.38
Ambient temperature sensor is in fault.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmRemoteTemperatureSensorFault 1.3.6.1.4.1.850.1.3.3.7.39
Remote temperature sensor is in fault.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmLowPressureSensorFault 1.3.6.1.4.1.850.1.3.3.7.40
Low pressure sensor is in fault.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmHighPressureSensorFault 1.3.6.1.4.1.850.1.3.3.7.41
High pressure sensor is in fault.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpCoolingAlarmSentrytimerTimeout 1.3.6.1.4.1.850.1.3.3.7.42
Sentry timer time out.
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarms 1.3.6.1.4.1.850.1.3.3.1.1
OBJECT IDENTIFIER    

tlpAutoProbeAlarm01 1.3.6.1.4.1.850.1.3.3.1.1.1
Auto Probe 1 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm02 1.3.6.1.4.1.850.1.3.3.1.1.2
Auto Probe 2 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm03 1.3.6.1.4.1.850.1.3.3.1.1.3
Auto Probe 3 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm04 1.3.6.1.4.1.850.1.3.3.1.1.4
Auto Probe 4 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm05 1.3.6.1.4.1.850.1.3.3.1.1.5
Auto Probe 5 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm06 1.3.6.1.4.1.850.1.3.3.1.1.6
Auto Probe 6 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm07 1.3.6.1.4.1.850.1.3.3.1.1.7
Auto Probe 7 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm08 1.3.6.1.4.1.850.1.3.3.1.1.8
Auto Probe 8 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm09 1.3.6.1.4.1.850.1.3.3.1.1.9
Auto Probe 9 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm10 1.3.6.1.4.1.850.1.3.3.1.1.10
Auto Probe 10 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm11 1.3.6.1.4.1.850.1.3.3.1.1.11
Auto Probe 11 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm12 1.3.6.1.4.1.850.1.3.3.1.1.12
Auto Probe 12 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm13 1.3.6.1.4.1.850.1.3.3.1.1.13
Auto Probe 13 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm14 1.3.6.1.4.1.850.1.3.3.1.1.14
Auto Probe 14 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm15 1.3.6.1.4.1.850.1.3.3.1.1.15
Auto Probe 15 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm16 1.3.6.1.4.1.850.1.3.3.1.1.16
Auto Probe 16 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm17 1.3.6.1.4.1.850.1.3.3.1.1.17
Auto Probe 17 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm18 1.3.6.1.4.1.850.1.3.3.1.1.18
Auto Probe 18 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm19 1.3.6.1.4.1.850.1.3.3.1.1.19
Auto Probe 19 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm20 1.3.6.1.4.1.850.1.3.3.1.1.20
Auto Probe 20 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm21 1.3.6.1.4.1.850.1.3.3.1.1.21
Auto Probe 21 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm22 1.3.6.1.4.1.850.1.3.3.1.1.22
Auto Probe 22 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm23 1.3.6.1.4.1.850.1.3.3.1.1.23
Auto Probe 23 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm24 1.3.6.1.4.1.850.1.3.3.1.1.24
Auto Probe 24 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm25 1.3.6.1.4.1.850.1.3.3.1.1.25
Auto Probe 25 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm26 1.3.6.1.4.1.850.1.3.3.1.1.26
Auto Probe 26 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm27 1.3.6.1.4.1.850.1.3.3.1.1.27
Auto Probe 27 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm28 1.3.6.1.4.1.850.1.3.3.1.1.28
Auto Probe 28 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm29 1.3.6.1.4.1.850.1.3.3.1.1.29
Auto Probe 29 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm30 1.3.6.1.4.1.850.1.3.3.1.1.30
Auto Probe 30 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm31 1.3.6.1.4.1.850.1.3.3.1.1.31
Auto Probe 31 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm32 1.3.6.1.4.1.850.1.3.3.1.1.32
Auto Probe 32 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm33 1.3.6.1.4.1.850.1.3.3.1.1.33
Auto Probe 33 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm34 1.3.6.1.4.1.850.1.3.3.1.1.34
Auto Probe 34 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm35 1.3.6.1.4.1.850.1.3.3.1.1.35
Auto Probe 35 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm36 1.3.6.1.4.1.850.1.3.3.1.1.36
Auto Probe 36 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm37 1.3.6.1.4.1.850.1.3.3.1.1.37
Auto Probe 37 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm38 1.3.6.1.4.1.850.1.3.3.1.1.38
Auto Probe 38 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm39 1.3.6.1.4.1.850.1.3.3.1.1.39
Auto Probe 39 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm40 1.3.6.1.4.1.850.1.3.3.1.1.40
Auto Probe 40 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm41 1.3.6.1.4.1.850.1.3.3.1.1.41
Auto Probe 41 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm42 1.3.6.1.4.1.850.1.3.3.1.1.42
Auto Probe 42 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm43 1.3.6.1.4.1.850.1.3.3.1.1.43
Auto Probe 43 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm44 1.3.6.1.4.1.850.1.3.3.1.1.44
Auto Probe 44 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm45 1.3.6.1.4.1.850.1.3.3.1.1.45
Auto Probe 45 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm46 1.3.6.1.4.1.850.1.3.3.1.1.46
Auto Probe 46 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm47 1.3.6.1.4.1.850.1.3.3.1.1.47
Auto Probe 47 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm48 1.3.6.1.4.1.850.1.3.3.1.1.48
Auto Probe 48 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm49 1.3.6.1.4.1.850.1.3.3.1.1.49
Auto Probe 49 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm50 1.3.6.1.4.1.850.1.3.3.1.1.50
Auto Probe 50 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm51 1.3.6.1.4.1.850.1.3.3.1.1.51
Auto Probe 51 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm52 1.3.6.1.4.1.850.1.3.3.1.1.52
Auto Probe 52 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm53 1.3.6.1.4.1.850.1.3.3.1.1.53
Auto Probe 53 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm54 1.3.6.1.4.1.850.1.3.3.1.1.54
Auto Probe 54 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm55 1.3.6.1.4.1.850.1.3.3.1.1.55
Auto Probe 55 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm56 1.3.6.1.4.1.850.1.3.3.1.1.56
Auto Probe 56 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm57 1.3.6.1.4.1.850.1.3.3.1.1.57
Auto Probe 57 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm58 1.3.6.1.4.1.850.1.3.3.1.1.58
Auto Probe 58 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm59 1.3.6.1.4.1.850.1.3.3.1.1.59
Auto Probe 59 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm60 1.3.6.1.4.1.850.1.3.3.1.1.60
Auto Probe 60 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm61 1.3.6.1.4.1.850.1.3.3.1.1.61
Auto Probe 61 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm62 1.3.6.1.4.1.850.1.3.3.1.1.62
Auto Probe 62 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm63 1.3.6.1.4.1.850.1.3.3.1.1.63
Auto Probe 63 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAutoProbeAlarm64 1.3.6.1.4.1.850.1.3.3.1.1.64
Auto Probe 64 had failed
Status: current Access: read-write
OBJECT-IDENTITY    

tlpAlarmControlTable 1.3.6.1.4.1.850.1.3.4.1
A list of alarm conditions supported for each device managed by this agent. This table contains zero, one, or many rows depending upon the number of available alarms managed by each device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TlpAlarmControlEntry

tlpAlarmControlEntry 1.3.6.1.4.1.850.1.3.4.1.1
An entry containing details for a particular alarm condition.
Status: current Access: not-accessible
OBJECT-TYPE    
  TlpAlarmControlEntry  

tlpAlarmControlIndex 1.3.6.1.4.1.850.1.3.4.1.1.1
The table row index for this alarm control entry for this device. The index of any one row represents the index of the alarm entry within the agent system. As such, the index values for any one device is not guaranteed to start with 1 or be numerically sequential.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

tlpAlarmControlDescr 1.3.6.1.4.1.850.1.3.4.1.1.2
A reference of the alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description for the alarm condition. The object referenced will be a well known alarm object associated with the device on which the alarm condition is active. This will be the same object description of an alarm when in alarm as referenced by tlpAlarmDescr.
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

tlpAlarmControlDetail 1.3.6.1.4.1.850.1.3.4.1.1.3
A textual description of the alarm condition. This will be the same textual description of an alarm when in alarm as referenced by tlpAlarmDetail.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

tlpAlarmControlSeverity 1.3.6.1.4.1.850.1.3.4.1.1.4
The severity of this alarm, which can be configured as desired for each alarm condition. This will be the same severity used when in alarm as referenced by tlpAlarmType.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER critical(1), warning(2), info(3)  

tlpNotificationsAlarmEntryAdded 1.3.6.1.4.1.850.1.4.1.1
This notification is sent each time an alarm condition is inserted into the device alarm table, tlpAlarmTable.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsAlarmEntryRemoved 1.3.6.1.4.1.850.1.4.1.2
This notification is sent each time an alarm condition is removed from the device alarm table, tlpAlarmTable.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotifySystemStartup 1.3.6.1.4.1.850.1.4.1.3
Used to inform another entity of an agent's startup. The varbinds that follow are: OBJ1 = tlpAgentType Obj1Value = The type of engine providing this data OBJ2 = tlpAgentVersion Obj2Value = The current version of the engine OBJ3 = tlpAgentMAC Obj3Value = The MAC address of the engine OBJ4 = tlpAgentSerialNum Obj4Value = The serial number of the web card [should be 0 on PC] --- if this trap is extended, place all static OIDs above this mark. all objects below --- the number of devices (tlpDeviceNumDevices) is explicit as per device for enumeration by --- the target receiver OBJ5 = tlpDeviceNumDevices Obj5Value = The number of devices attached --- The following objects will be replicated per each device: OBJ6 = The OID for an entry of tlpDeviceManufacturer, indexed by device Obj6Value = The device's manufacturer OBJ7 = The OID for an entry of tlpDeviceModel, indexed by device Obj7Value = The device's model name OBJ8 = The OID for an entry of tlpDeviceName, indexed by device Obj8Value = The device's display name OBJ9 = The OID for an entry of tlpDeviceLocation, indexed by device Obj9Value = The device's location OBJ10 = The OID for an entry of tlpDeviceRegion, indexed by device Obj10Value= The device's region OBJ11 = The OID for an entry of tlpDeviceProtocol, indexed by device Obj11Value= The device's protocol (display string format)
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotifySystemShutdown 1.3.6.1.4.1.850.1.4.1.4
Used to inform another entity of an agent's shutdown. The varbinds that follow are: OBJ1 = tlpAgentType Obj1Value = The type of engine providing this data OBJ2 = tlpAgentVersion Obj2Value = The current version of the engine OBJ3 = tlpAgentMAC Obj3Value = The MAC address of the engine OBJ4 = tlpAgentSerialNum Obj4Value = The serial number of the web card [should be 0 on PC] --- if this trap is extended, place all static OIDs above this mark. all objects below --- the number of devices (tlpDeviceNumDevices) is explicit as per device for enumeration by --- the target receiver OBJ5 = tlpDeviceNumDevices Obj5Value = The number of devices attached --- The following objects will be replicated per each device: OBJ6 = The OID for an entry of tlpDeviceManufacturer, indexed by device Obj6Value = The device's manufacturer OBJ7 = The OID for an entry of tlpDeviceModel, indexed by device Obj7Value = The device's model name OBJ8 = The OID for an entry of tlpDeviceName, indexed by device Obj8Value = The device's display name OBJ9 = The OID for an entry of tlpDeviceLocation, indexed by device Obj9Value = The device's location OBJ10 = The OID for an entry of tlpDeviceRegion, indexed by device Obj10Value= The device's region OBJ11 = The OID for an entry of tlpDeviceProtocol, indexed by device Obj11Value= The device's protocol (display string format)
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotifySystemUpdate 1.3.6.1.4.1.850.1.4.1.5
Used to inform another entity of an engine's startup. The varbinds that follow are: OBJ1 = tlpAgentType Obj1Value = The type of engine providing this data OBJ2 = tlpAgentVersion Obj2Value = The current version of the engine OBJ3 = tlpAgentMAC Obj3Value = The MAC address of the engine OBJ4 = tlpAgentSerialNum Obj4Value = The serial number of the web card [should be 0 on PC] --- if this trap is extended, place all static OIDs above this mark. all objects below --- the number of devices (tlpDeviceNumDevices) is explicit as per device for enumeration by --- the target receiver OBJ5 = tlpDeviceNumDevices Obj5Value = The number of devices attached --- The following objects will be replicated per each device: OBJ6 = The OID for an entry of tlpDeviceManufacturer, indexed by device Obj6Value = The device's manufacturer OBJ7 = The OID for an entry of tlpDeviceModel, indexed by device Obj7Value = The device's model name OBJ8 = The OID for an entry of tlpDeviceName, indexed by device Obj8Value = The device's display name OBJ9 = The OID for an entry of tlpDeviceLocation, indexed by device Obj9Value = The device's location OBJ10 = The OID for an entry of tlpDeviceRegion, indexed by device Obj10Value= The device's region OBJ11 = The OID for an entry of tlpDeviceProtocol, indexed by device Obj11Value= The device's protocol (display string format)
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotifyTest 1.3.6.1.4.1.850.1.4.1.6
Used when performing a test of the system or an alert notification contact. The varbinds that follow are: OBJ1 = tlpAgentType Obj1Value = The type of engine providing this data OBJ2 = tlpAgentVersion Obj2Value = The current version of the engine OBJ3 = tlpAgentMAC Obj3Value = The MAC address of the engine OBJ4 = tlpAgentSerialNum Obj4Value = The serial number of the web card [should be 0 on PC]
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsAgent 1.3.6.1.4.1.850.1.4.2.1
OBJECT IDENTIFIER    

tlpNotificationsDevice 1.3.6.1.4.1.850.1.4.2.2
OBJECT IDENTIFIER    

tlpNotificationsDeviceInternalFirmwareFault 1.3.6.1.4.1.850.1.4.2.2.1
This notification is sent when the device experiences an internal firmware failure.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsDeviceInternalHardwareFault 1.3.6.1.4.1.850.1.4.2.2.2
This notification is sent when the device experiences an internal hardware failure.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsDeviceConfigurationChange 1.3.6.1.4.1.850.1.4.2.2.3
This notification is sent when the device configuration changes.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsDeviceFirmwareUpdate 1.3.6.1.4.1.850.1.4.2.2.4
This notification is sent when the device firmware is updated.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsDeviceMicrocontrollerReset 1.3.6.1.4.1.850.1.4.2.2.5
This notification is sent when the device microcontroller resets.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsDeviceSystemInformation 1.3.6.1.4.1.850.1.4.2.2.6
This notification is sent when the device sysytem information changes.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsDeviceNvrChecksumMismatch 1.3.6.1.4.1.850.1.4.2.2.7
This notification is sent when the NVR is corrupted.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsDeviceUsbCommunicationsEstablished 1.3.6.1.4.1.850.1.4.2.2.8
This notification is sent when the device USB communications is established.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsDeviceUsbCommunicationsLost 1.3.6.1.4.1.850.1.4.2.2.9
This notification is sent when the device USB communications is lost.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsDevicePowerSupplyShutdown 1.3.6.1.4.1.850.1.4.2.2.10
This notification is sent when the device reports a shutdown occurred due to a power supply fault.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsDeviceOverLoadShutdown 1.3.6.1.4.1.850.1.4.2.2.11
This notification is sent when the device reports a shutdown occurred due to an over load fault.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsDeviceCurrentLimitShutdown 1.3.6.1.4.1.850.1.4.2.2.12
This notification is sent when the device reports a shutdown occurred due to a current limit fault.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsDeviceOverTemperatureShutdown 1.3.6.1.4.1.850.1.4.2.2.13
This notification is sent when the device reports a shutdown occurred due to an over temperature fault.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsDeviceModeTransitionTimeout 1.3.6.1.4.1.850.1.4.2.2.14
This notification is sent when the device timed out transitioning to a mode.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsDeviceFailedModeTransitionToIdle 1.3.6.1.4.1.850.1.4.2.2.15
This notification is sent when the device failed a transition to idle mode.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsDeviceInternalCommunicationsLost 1.3.6.1.4.1.850.1.4.2.2.16
This notification is sent when the device lost internal communications.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsDeviceAcknowledgeFaults 1.3.6.1.4.1.850.1.4.2.2.17
This notification is sent when device faults are acknowledged.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsDeviceTransferToReboot 1.3.6.1.4.1.850.1.4.2.2.18
This notification is sent when a device reboot occurred.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsDeviceTransferToWatchdogReboot 1.3.6.1.4.1.850.1.4.2.2.19
This notification is sent when a device reboot occurred due to a watchdog fault.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsDeviceTransferToLatchedIdle 1.3.6.1.4.1.850.1.4.2.2.20
This notification is sent when the device transferred to latched idle mode.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsDeviceTransferToLatchedStandby 1.3.6.1.4.1.850.1.4.2.2.21
This notification is sent when the device transferred to latched standby mode.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsDeviceTransferToLatchedLine 1.3.6.1.4.1.850.1.4.2.2.22
This notification is sent when the device transferred to latched line mode.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsDeviceFailSafeClockMonitorEngaged 1.3.6.1.4.1.850.1.4.2.2.23
This notification is sent when the fail safe clock monitor is engaged.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsDeviceTransferToIdle 1.3.6.1.4.1.850.1.4.2.2.24
This notification is sent when the device transferred to idle mode.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsDeviceVoutUnderVoltageShutdown 1.3.6.1.4.1.850.1.4.2.2.25
This notification is sent when the device reports a shutdown occurred due to a vout under voltage fault.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsDeviceVoutOverVoltageShutdown 1.3.6.1.4.1.850.1.4.2.2.26
This notification is sent when the device reports a shutdown occurred due to a vout over voltage fault.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsDeviceUnhandledFault 1.3.6.1.4.1.850.1.4.2.2.27
This notification is sent when the device reports an unhandled fault.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsUps 1.3.6.1.4.1.850.1.4.2.3
OBJECT IDENTIFIER    

tlpNotificationsUpsBatteryLowVoltageShutdown 1.3.6.1.4.1.850.1.4.2.3.1
This notification is sent when the ups reports a shutdown occurred due to a low battery voltage fault.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsUpsBatteryLowPercentageShutdown 1.3.6.1.4.1.850.1.4.2.3.2
This notification is sent when the ups reports a shutdown occurred due to a low battery percentage fault.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsUpsBatteryOverVoltageShutdown 1.3.6.1.4.1.850.1.4.2.3.3
This notification is sent when the ups reports a shutdown occurred due to a battery over voltage fault.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsUpsBatteryOverCurrentShutdown 1.3.6.1.4.1.850.1.4.2.3.4
This notification is sent when the ups reports a shutdown occurred due to a battery over current fault.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsUpsBatteryUnknownTypeShutdown 1.3.6.1.4.1.850.1.4.2.3.5
This notification is sent when the ups reports a shutdown occurred due to an unknown battery type fault.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsUpsBatteryConfigurationMismatch 1.3.6.1.4.1.850.1.4.2.3.6
This notification is sent when the ups battery configuration is mismatched.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsUpsBatteryUnderVoltageShutdown 1.3.6.1.4.1.850.1.4.2.3.7
This notification is sent when the ups reports a shutdown occurred due to a battery under voltage fault.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsUpsSlaBatteryOverTemperatureShutdown 1.3.6.1.4.1.850.1.4.2.3.8
This notification is sent when the ups reports a shutdown occurred due to an SLA battery over temperature fault.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsUpsBatteryInstallation 1.3.6.1.4.1.850.1.4.2.3.9
This notification is sent when a battery installation occurs.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsUpsChargerBulkToAcceptance 1.3.6.1.4.1.850.1.4.2.3.10
This notification is sent when ups battery charging.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsUpsChargerAcceptanceToFloat 1.3.6.1.4.1.850.1.4.2.3.11
This notification is sent when ups battery fully charged.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsUpsChargerFloatToBulk 1.3.6.1.4.1.850.1.4.2.3.12
This notification is sent when ups battery not fully charged.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsUpsTransferToSelftest 1.3.6.1.4.1.850.1.4.2.3.13
This notification is sent when a self test is initiated.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsUpsTransferToEconomy 1.3.6.1.4.1.850.1.4.2.3.14
This notification is sent when the device transferred to economy mode.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsUpsLineConnectRelayFaultShutdown 1.3.6.1.4.1.850.1.4.2.3.15
This notification is sent when the device reports a shutdown occurred due to line connect relay fault.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsUpsTransferToFaultBypass 1.3.6.1.4.1.850.1.4.2.3.16
This notification is sent when the device transferred to fault bypass mode.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsUpsBypassPowerDistributionModuleDisconnected 1.3.6.1.4.1.850.1.4.2.3.17
This notification is sent when bypass power distribution module is disconnected.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsUpsManualBypassActivatedFromUnsupportedMode 1.3.6.1.4.1.850.1.4.2.3.18
This notification is sent when manual bypass activated from an unsupported UPS mode.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsUpsOnBatteryTimeoutShutdown 1.3.6.1.4.1.850.1.4.2.3.19
This notification is sent when the device reports a shutdown occurred due to on battery timeout.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsUpsLowBatteryPercentageShutdown 1.3.6.1.4.1.850.1.4.2.3.20
This notification is sent when the device reports a shutdown occurred due to low battery percentage.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsPdu 1.3.6.1.4.1.850.1.4.2.4
OBJECT IDENTIFIER    

tlpNotificationsEnvirosense 1.3.6.1.4.1.850.1.4.2.5
OBJECT IDENTIFIER    

tlpNotificationsAts 1.3.6.1.4.1.850.1.4.2.6
OBJECT IDENTIFIER    

tlpNotificationsAtsSource1NotAvailable 1.3.6.1.4.1.850.1.4.2.6.1
This notification is sent when input on source one is not available. For atss with the designation of primary and secondary, this notification denotes input on the primary source is not available.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsAtsSource2NotAvailable 1.3.6.1.4.1.850.1.4.2.6.2
This notification is sent when input on source two is not available. For atss with the designation of primary and secondary, this notification denotes input on the secondary source is not available.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsAtsLockdownToSource1 1.3.6.1.4.1.850.1.4.2.6.3
This notification is sent upon a transfer circuit fault causing the device to be locked on source 1.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsAtsLockdownToSource2 1.3.6.1.4.1.850.1.4.2.6.4
This notification is sent upon a transfer circuit fault causing the device to be locked on source 2.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsAtsSource1Available 1.3.6.1.4.1.850.1.4.2.6.5
This notification is sent when source 1 is available and ready for use.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsAtsSource2Available 1.3.6.1.4.1.850.1.4.2.6.6
This notification is sent when source 2 is available and ready for use.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsAtsSource1Brownout 1.3.6.1.4.1.850.1.4.2.6.7
This notification is sent when a brownout condition occurred on source 1.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsAtsSource2Brownout 1.3.6.1.4.1.850.1.4.2.6.8
This notification is sent when a brownout condition occurred on source 2.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsAtsSource1VoltageDrop 1.3.6.1.4.1.850.1.4.2.6.9
This notification is sent when the voltage on source 1 drops below a usable state.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsAtsSource2VoltageDrop 1.3.6.1.4.1.850.1.4.2.6.10
This notification is sent when the voltage on source 2 drops below a usable state.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsAtsTimedReturnToSource1 1.3.6.1.4.1.850.1.4.2.6.11
This notification is sent when the active input source returns to source 1 from source 2 after a delay time expires.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsAtsTimedReturnToSource2 1.3.6.1.4.1.850.1.4.2.6.12
This notification is sent when the active input source returns to source 2 from source 1 after a delay time expires.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsAtsTransferToSource1 1.3.6.1.4.1.850.1.4.2.6.13
This notification is sent when the active input source transfers from source 2 to source 1.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsAtsTransferToSource2 1.3.6.1.4.1.850.1.4.2.6.14
This notification is sent when the active input source transfers from source 1 to source 2.
Status: current Access: read-write
NOTIFICATION-TYPE    

tlpNotificationsCooling 1.3.6.1.4.1.850.1.4.2.7
OBJECT IDENTIFIER    

tlpNotificationsKvm 1.3.6.1.4.1.850.1.4.2.8
OBJECT IDENTIFIER    

tlpNotificationsRackTrack 1.3.6.1.4.1.850.1.4.2.9
OBJECT IDENTIFIER    

tlpNotificationsSwitch 1.3.6.1.4.1.850.1.4.2.10
OBJECT IDENTIFIER    

tlpNotifyEventTableRef 1.3.6.1.4.1.850.1.4.3.1
This value references the OID of a table object applicable to the event condition. This, in conjunction with the table row as defined by tlpAlarmTableRowRef, specifies the object/row within this table to which the event condition applies. Refer to tlpAlarmTableRef for more information.
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

tlpNotifyEventTableRowRef 1.3.6.1.4.1.850.1.4.3.2
This value is used in conjunction with tlpNotifyEventTableRef to define the object associated with this event condition. See the description of tlpNotifyEventTableRef for more information.
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER