IEEE8021-PSFP-MIB

File: IEEE8021-PSFP-MIB.mib (49795 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
IEEE8021-TC-MIB IEEE8021-BRIDGE-MIB IEEE8021-ST-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Unsigned32
Integer32 Counter64 TruthValue
RowStatus MODULE-COMPLIANCE OBJECT-GROUP
ieee802dot1mibs ieee8021BridgeBaseComponentId IEEE8021STPTPtimeValue

Defined Types

Ieee8021PSFPStreamFilterEntry  
SEQUENCE    
  ieee8021PSFPStreamFilterInstance Unsigned32
  ieee8021PSFPStreamHandleSpec Integer32
  ieee8021PSFPPrioritySpec Integer32
  ieee8021PSFPStreamGateInstanceID Unsigned32
  ieee8021PSFPFilterSpecificationList OCTET STRING
  ieee8021PSFPMatchingFramesCount Counter64
  ieee8021PSFPPassingFramesCount Counter64
  ieee8021PSFPNotPassingFramesCount Counter64
  ieee8021PSFPPassingSDUCount Counter64
  ieee8021PSFPNotPassingSDUCount Counter64
  ieee8021PSFPREDFramesCount Counter64
  ieee8021PSFPStreamBlockedDueToOversizeFrameEnable TruthValue
  ieee8021PSFPStreamBlockedDueToOversizeFrame TruthValue
  ieee8021PSFPStreamFilterEntryRowStatus RowStatus

Ieee8021PSFPStreamGateEntry  
SEQUENCE    
  ieee8021PSFPStreamGateInstance Unsigned32
  ieee8021PSFPGateEnabled TruthValue
  ieee8021PSFPAdminGateStates INTEGER
  ieee8021PSFPOperGateStates INTEGER
  ieee8021PSFPAdminControlListLength Unsigned32
  ieee8021PSFPOperControlListLength Unsigned32
  ieee8021PSFPAdminControlList OCTET STRING
  ieee8021PSFPOperControlList OCTET STRING
  ieee8021PSFPAdminCycleTimeNumerator Unsigned32
  ieee8021PSFPAdminCycleTimeDenominator Unsigned32
  ieee8021PSFPOperCycleTimeNumerator Unsigned32
  ieee8021PSFPOperCycleTimeDenominator Unsigned32
  ieee8021PSFPAdminCycleTimeExtension Unsigned32
  ieee8021PSFPOperCycleTimeExtension Unsigned32
  ieee8021PSFPAdminBaseTime IEEE8021STPTPtimeValue
  ieee8021PSFPOperBaseTime IEEE8021STPTPtimeValue
  ieee8021PSFPConfigChange TruthValue
  ieee8021PSFPConfigChangeTime IEEE8021STPTPtimeValue
  ieee8021PSFPTickGranularity Unsigned32
  ieee8021PSFPCurrentTime IEEE8021STPTPtimeValue
  ieee8021PSFPConfigPending TruthValue
  ieee8021PSFPConfigChangeError Counter64
  ieee8021PSFPAdminIPV Integer32
  ieee8021PSFPOperIPV Integer32
  ieee8021PSFPGateClosedDueToInvalidRxEnable TruthValue
  ieee8021PSFPGateClosedDueToInvalidRx TruthValue
  ieee8021PSFPGateClosedDueToOctetsExceededEnable TruthValue
  ieee8021PSFPGateClosedDueToOctetsExceeded TruthValue
  ieee8021PSFPStreamGateEntryRowStatus RowStatus

Ieee8021PSFPFlowMeterEntry  
SEQUENCE    
  ieee8021PSFPFlowMeterInstance Unsigned32
  ieee8021PSFPFlowMeterCIR Unsigned32
  ieee8021PSFPFlowMeterCBS Unsigned32
  ieee8021PSFPFlowMeterEIR Unsigned32
  ieee8021PSFPFlowMeterEBS Unsigned32
  ieee8021PSFPFlowMeterCF Integer32
  ieee8021PSFPFlowMeterCM INTEGER
  ieee8021PSFPFlowMeterDropOnYellow TruthValue
  ieee8021PSFPFlowMeterMarkAllFramesRedEnable TruthValue
  ieee8021PSFPFlowMeterMarkAllFramesRed TruthValue
  ieee8021PSFPFlowMeterEntryRowStatus RowStatus

Ieee8021PSFPStreamParameterEntry  
SEQUENCE    
  ieee8021PSFPMaxStreamFilterInstances Unsigned32
  ieee8021PSFPMaxStreamGateInstances Unsigned32
  ieee8021PSFPMaxFlowMeterInstances Unsigned32
  ieee8021PSFPSupportedListMax Unsigned32

Defined Values

ieee8021PSFPMib 1.3.111.2.802.1.1.31
The Bridge MIB module for managing devices that support the Per-Stream Filtering and Policing enhancements for IEEE 802.1Q Bridges. Unless otherwise indicated, the references in this MIB module are to IEEE Std 802.1Q. Copyright (C) IEEE (2018). This version of this MIB module is part of IEEE Std 802.1Q; see the draft itself for full legal notices.
MODULE-IDENTITY    

ieee8021PSFPNotifications 1.3.111.2.802.1.1.31.0
OBJECT IDENTIFIER    

ieee8021PSFPObjects 1.3.111.2.802.1.1.31.1
OBJECT IDENTIFIER    

ieee8021PSFPConformance 1.3.111.2.802.1.1.31.2
OBJECT IDENTIFIER    

ieee8021PSFPStreamFilterParameters 1.3.111.2.802.1.1.31.1.1
OBJECT IDENTIFIER    

ieee8021PSFPStreamGateParameters 1.3.111.2.802.1.1.31.1.2
OBJECT IDENTIFIER    

ieee8021PSFPFlowMeterParameters 1.3.111.2.802.1.1.31.1.3
OBJECT IDENTIFIER    

ieee8021PSFPStreamParameters 1.3.111.2.802.1.1.31.1.4
OBJECT IDENTIFIER    

ieee8021PSFPStreamFilterTable 1.3.111.2.802.1.1.31.1.1.1
A table that contains the per-filter instance manageable parameters for stream filters. A row in the table exists for each stream filter instance. associated with a Bridge component. All writable objects in this table must be persistent over power up restart/reboot.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ieee8021PSFPStreamFilterEntry

ieee8021PSFPStreamFilterEntry 1.3.111.2.802.1.1.31.1.1.1.1
A list of objects that contains the manageable parameters for stream filters for a Bridge component.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ieee8021PSFPStreamFilterEntry  

ieee8021PSFPStreamFilterInstance 1.3.111.2.802.1.1.31.1.1.1.1.1
The StreamFilterInstance parameter is an index into the StreamFilterTable. The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

ieee8021PSFPStreamHandleSpec 1.3.111.2.802.1.1.31.1.1.1.1.2
The StreamHandleSpec parameter contains a stream identifier specification value. A value of -1 denotes the wild card value; all positive values denote stream identifier values. The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -1..2147483647  

ieee8021PSFPPrioritySpec 1.3.111.2.802.1.1.31.1.1.1.1.3
The PrioritySpec parameter contains a priority specification value. A value of -1 denotes the wild card value; zero or positive values denote priority values. The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -1..2147483647  

ieee8021PSFPStreamGateInstanceID 1.3.111.2.802.1.1.31.1.1.1.1.4
The StreamGateInstance parameter contains the index of an entry in the Stream Gate Table. The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

ieee8021PSFPFilterSpecificationList 1.3.111.2.802.1.1.31.1.1.1.1.5
The FilterSpecificationList parameter contains a list of filter specifications associated with this stream filter. The octet string value represents the contents of the list as an ordered list of entries, each encoded as a TLV, as follows. The first octet of each TLV is interpreted as an unsigned integer representing a filter specification type: 0: Maximum SDU Size. 1: Flow meter instance identifier. 2-255: Reserved for future gate operations The second and third octets of the TLV are the length field, interpreted as an unsigned integer, indicating the number of octets of the value that follows the length. A length of zero indicates that there is no value (i.e., the filter specification has no parameters). The fourth through (4 + length -1)th octets encode the parameters of the filter specification, as defined for each filter specification type. - Maximum SDU Size: A single SDU size parameter is encoded in four octets, and is interpreted as an unsigned integer value. - Flow meter instance identifier: A single flow meter instance identifier is encoded in four octets, and is interpreted as an unsigned integer value. The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING  

ieee8021PSFPMatchingFramesCount 1.3.111.2.802.1.1.31.1.1.1.1.6
The MatchingFramesCount counter counts received frames that match this stream filter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

ieee8021PSFPPassingFramesCount 1.3.111.2.802.1.1.31.1.1.1.1.7
The PassingFramesCount counter counts received frames that pass the gate associated with this stream filter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

ieee8021PSFPNotPassingFramesCount 1.3.111.2.802.1.1.31.1.1.1.1.8
The NotPassingFramesCount counter counts received frames that do not pass the gate associated with this stream filter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

ieee8021PSFPPassingSDUCount 1.3.111.2.802.1.1.31.1.1.1.1.9
The PassingSDUCount counter counts received frames that pass the SDU size filter specification associated with this stream filter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

ieee8021PSFPNotPassingSDUCount 1.3.111.2.802.1.1.31.1.1.1.1.10
The NotPassingSDUCount counter counts received frames that do not pass the SDU size filter specification associated with this stream filter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

ieee8021PSFPREDFramesCount 1.3.111.2.802.1.1.31.1.1.1.1.11
The REDFramesCount counter counts received frames that were discarded as a result of the operation of the flow meter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

ieee8021PSFPStreamBlockedDueToOversizeFrameEnable 1.3.111.2.802.1.1.31.1.1.1.1.12
The ieee8021PSFPStreamBlockedDueToOversizeFrameEnable object contains a Boolean value that indicates whether the ieee8021PSFPStreamBlockedDueToOversizeFrame function is enabled (TRUE) or disabled (FALSE). The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

ieee8021PSFPStreamBlockedDueToOversizeFrame 1.3.111.2.802.1.1.31.1.1.1.1.13
The ieee8021PSFPStreamBlockedDueToOversizeFrame object contains a Boolean value that indicates whether, if the ieee8021PSFPStreamBlockedDueToOversizeFrame function is enabled, all frames are to be discarded (TRUE) or not (FALSE). The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

ieee8021PSFPStreamFilterEntryRowStatus 1.3.111.2.802.1.1.31.1.1.1.1.14
The status of the row. The writable columns in a row cannot be changed if the row is active. All columns MUST have a valid value before a row can be activated.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

ieee8021PSFPStreamGateTable 1.3.111.2.802.1.1.31.1.2.1
A table that contains the per-gate instance manageable parameters for stream gate scheduling. For a given Bridge component, a row in the table exists for each stream gate instance. All writable objects in this table must be persistent over power up restart/reboot.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ieee8021PSFPStreamGateEntry

ieee8021PSFPStreamGateEntry 1.3.111.2.802.1.1.31.1.2.1.1
A list of objects that contains the manageable parameters for stream gate scheduling for a Bridge component.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ieee8021PSFPStreamGateEntry  

ieee8021PSFPStreamGateInstance 1.3.111.2.802.1.1.31.1.2.1.1.1
The StreamGateInstance parameter is an index into the StreamGateTable. The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

ieee8021PSFPGateEnabled 1.3.111.2.802.1.1.31.1.2.1.1.2
The GateEnabled parameter determines whether the stream gate is active (true) or inactive (false). The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

ieee8021PSFPAdminGateStates 1.3.111.2.802.1.1.31.1.2.1.1.3
The administrative value of the GateStates parameter for the stream gate. The open value indicates that the gate is open, the closed value indicates that the gate is closed. The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

ieee8021PSFPOperGateStates 1.3.111.2.802.1.1.31.1.2.1.1.4
The operational value of the GateStates parameter for the stream gate. The open value indicates that the gate is open, the closed value indicates that the gate is closed.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

ieee8021PSFPAdminControlListLength 1.3.111.2.802.1.1.31.1.2.1.1.5
The administrative value of the ListMax parameter for the gate. The integer value indicates the number of entries (TLVs) in the AdminControlList. The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

ieee8021PSFPOperControlListLength 1.3.111.2.802.1.1.31.1.2.1.1.6
The operational value of the ListMax parameter for the gate. The integer value indicates the number of entries (TLVs) in the OperControlList.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ieee8021PSFPAdminControlList 1.3.111.2.802.1.1.31.1.2.1.1.7
The administrative value of the ControlList parameter for the gate. The octet string value represents the contents of the control list as an ordered list of entries, each encoded as a TLV, as follows. The first octet of each TLV is interpreted as an unsigned integer representing a gate operation name: 0: SetGateAndIPV 1-255: Reserved for future gate operations The second octet of the TLV is the length field, interpreted as an unsigned integer, indicating the number of octets of the value that follows the length. A length of zero indicates that there is no value (i.e., the gate operation has no parameters). The third through (3 + length -1)th octets encode the parameters of the gate operation, in the order that they appear in the definition of the operation in Table 8-4. Three parameter types are defined: - StreamGateState: A GateState parameter is encoded in a single octet, and is interpreted as an integer value. The value 1 indicates open; the value 2 indicates closed. - IPV: An IPV is encoded in four octets as a 32-bit signed integer. A negative denotes the null value; zero or positive values denote internal priority values. - TimeInterval: A TimeInterval is encoded in 4 octets as a 32-bit unsigned integer, representing a number of nanoseconds. The first octet encodes the most significant 8 bits of the integer, and the fourth octet encodes the least significant 8 bits. - IntervalOctetMax: An integer representing the maximum number of MSDU octets that are permitted to pas the gate during the specified TimeInterval. If this parameter is omitted, there is no maximum. The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING  

ieee8021PSFPOperControlList 1.3.111.2.802.1.1.31.1.2.1.1.8
The operational value of the ControlList parameter for the gate. The octet string value represents the contents of the control list as an ordered list of entries, each encoded as a TLV, as follows. The first octet of each TLV is interpreted as an unsigned integer representing a gate operation name: 0: SetGateAndIPV 1-255: Reserved for future gate operations The second octet of the TLV is the length field, interpreted as an unsigned integer, indicating the number of octets of the value that follows the length. A length of zero indicates that there is no value (i.e., the gate operation has no parameters). The third through (3 + length -1)th octets encode the parameters of the gate operation, in the order that they appear in the definition of the operation in Table 8-4. Three parameter types are defined: - StreamGateState: A GateState parameter is encoded in a single octet, and is interpreted as an integer value. The value 1 indicates open; the value 2 indicates closed. - IPV: An IPV is encoded in four octets as a 32-bit signed integer. A negative value denotes the null value; zero and positive values denote internal priority values. - TimeInterval: A TimeInterval is encoded in 4 octets as a 32-bit unsigned integer, representing a number of nanoseconds. The first octet encodes the most significant 8 bits of the integer, and the fourth octet encodes the least significant 8 bits. - IntervalOctetMax: An integer representing the maximum number of MSDU octets that are permitted to pas the gate during the specified TimeInterval. If this parameter is omitted, there is no maximum.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

ieee8021PSFPAdminCycleTimeNumerator 1.3.111.2.802.1.1.31.1.2.1.1.9
The administrative value of the numerator of the CycleTime parameter for the gate. The numerator and denominator together represent the cycle time as a rational number of seconds. The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

ieee8021PSFPAdminCycleTimeDenominator 1.3.111.2.802.1.1.31.1.2.1.1.10
The administrative value of the denominator of the CycleTime parameter for the gate. The numerator and denominator together represent the cycle time as a rational number of seconds. The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

ieee8021PSFPOperCycleTimeNumerator 1.3.111.2.802.1.1.31.1.2.1.1.11
The operational value of the numerator of the CycleTime parameter for the gate. The numerator and denominator together represent the cycle time as a rational number of seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ieee8021PSFPOperCycleTimeDenominator 1.3.111.2.802.1.1.31.1.2.1.1.12
The operational value of the denominator of the CycleTime parameter for the gate. The numerator and denominator together represent the cycle time as a rational number of seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ieee8021PSFPAdminCycleTimeExtension 1.3.111.2.802.1.1.31.1.2.1.1.13
The administrative value of the CycleTimeExtension parameter for the gate. The value is an unsigned integer number of nanoseconds. The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

ieee8021PSFPOperCycleTimeExtension 1.3.111.2.802.1.1.31.1.2.1.1.14
The operational value of the CycleTimeExtension parameter for the gate. The value is an unsigned integer number of nanoseconds.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ieee8021PSFPAdminBaseTime 1.3.111.2.802.1.1.31.1.2.1.1.15
The administrative value of the BaseTime parameter for the gate. The value is a representation of a PTPtime value, consisting of a 48-bit integer number of seconds and a 32-bit integer number of nanoseconds. The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  IEEE8021STPTPtimeValue  

ieee8021PSFPOperBaseTime 1.3.111.2.802.1.1.31.1.2.1.1.16
The operationsl value of the BaseTime parameter for the gate. The value is a representation of a PTPtime value, consisting of a 48-bit integer number of seconds and a 32-bit integer number of nanoseconds.
Status: current Access: read-only
OBJECT-TYPE    
  IEEE8021STPTPtimeValue  

ieee8021PSFPConfigChange 1.3.111.2.802.1.1.31.1.2.1.1.17
The ConfigChange parameter signals the start of a configuration change for the gate when it is set to TRUE. This should only be done when the various administrative parameters are all set to appropriate values.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

ieee8021PSFPConfigChangeTime 1.3.111.2.802.1.1.31.1.2.1.1.18
The PTPtime at which the next config change is scheduled to occur. The value is a representation of a PTPtime value, consisting of a 48-bit integer number of seconds and a 32-bit integer number of nanoseconds. The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-only
OBJECT-TYPE    
  IEEE8021STPTPtimeValue  

ieee8021PSFPTickGranularity 1.3.111.2.802.1.1.31.1.2.1.1.19
The granularity of the cycle time clock, represented as an unsigned number of tenths of nanoseconds. The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ieee8021PSFPCurrentTime 1.3.111.2.802.1.1.31.1.2.1.1.20
The current time, in PTPtime, as maintained by the local system. The value is a representation of a PTPtime value, consisting of a 48-bit integer number of seconds and a 32-bit integer number of nanoseconds.
Status: current Access: read-only
OBJECT-TYPE    
  IEEE8021STPTPtimeValue  

ieee8021PSFPConfigPending 1.3.111.2.802.1.1.31.1.2.1.1.21
The value of the ConfigPending state machine variable. The value is TRUE if a configuration change is in progress but has not yet completed.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ieee8021PSFPConfigChangeError 1.3.111.2.802.1.1.31.1.2.1.1.23
A counter of the number of times that a re-configuration of the traffic schedule has been requested with the old schedule still running and the requested base time was in the past.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

ieee8021PSFPAdminIPV 1.3.111.2.802.1.1.31.1.2.1.1.24
The administrative value of the IPV parameter for the gate. A value of -1 denotes the null value.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -1..2147483647  

ieee8021PSFPOperIPV 1.3.111.2.802.1.1.31.1.2.1.1.25
The operational value of the IPV parameter for the gate. A value of -1 denotes the null value.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -1..2147483647  

ieee8021PSFPGateClosedDueToInvalidRxEnable 1.3.111.2.802.1.1.31.1.2.1.1.26
The PSFPGateClosedDueToInvalidRxEnable object contains a Boolean value that indicates whether the PSFPGateClosedDueToInvalidRx function is enabled (TRUE) or disabled (FALSE). The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

ieee8021PSFPGateClosedDueToInvalidRx 1.3.111.2.802.1.1.31.1.2.1.1.27
The PSFPGateClosedDueToInvalidRx object contains a Boolean value that indicates whether, if the PSFPGateClosedDueToInvalidRx function is enabled, all frames are to be discarded (TRUE) or not (FALSE). The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

ieee8021PSFPGateClosedDueToOctetsExceededEnable 1.3.111.2.802.1.1.31.1.2.1.1.28
The PSFPGateClosedDueToOctetsExceededEnable object contains a Boolean value that indicates whether the PSFPGateClosedDueToOctetsExceeded function is enabled (TRUE) or disabled (FALSE). The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

ieee8021PSFPGateClosedDueToOctetsExceeded 1.3.111.2.802.1.1.31.1.2.1.1.29
The PSFPGateClosedDueToOctetsExceeded parameter contains a Boolean value that indicates whether, if the PSFPGateClosedDueToOctetsExceeded function is enabled, all frames are to be discarded (TRUE) or not (FALSE). The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

ieee8021PSFPStreamGateEntryRowStatus 1.3.111.2.802.1.1.31.1.2.1.1.30
The status of the row. The writable columns in a row cannot be changed if the row is active. All columns MUST have a valid value before a row can be activated.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

ieee8021PSFPFlowMeterTable 1.3.111.2.802.1.1.31.1.3.1
A table that contains the per-meter instance manageable parameters for flow meters. For a given Bridge component, a row in the table exists for each flow meter instance. All writable objects in this table must be persistent over power up restart/reboot.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ieee8021PSFPFlowMeterEntry

ieee8021PSFPFlowMeterEntry 1.3.111.2.802.1.1.31.1.3.1.1
A list of objects that contains the manageable parameters for flow meters for a Bridge component.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ieee8021PSFPFlowMeterEntry  

ieee8021PSFPFlowMeterInstance 1.3.111.2.802.1.1.31.1.3.1.1.1
The FlowMeterInstance parameter is an index into the FlowMeterTable. The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

ieee8021PSFPFlowMeterCIR 1.3.111.2.802.1.1.31.1.3.1.1.2
The FlowMeterCIR parameter contains an integer value that represents the CIR value for the flow meter, in bit/second. The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

ieee8021PSFPFlowMeterCBS 1.3.111.2.802.1.1.31.1.3.1.1.3
The FlowMeterCBS parameter contains an integer value that represents the CBS value for the flow meter, in octets. The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

ieee8021PSFPFlowMeterEIR 1.3.111.2.802.1.1.31.1.3.1.1.4
The FlowMeterEIR parameter contains an integer value that represents the EIR value for the flow meter, in bit/second. The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

ieee8021PSFPFlowMeterEBS 1.3.111.2.802.1.1.31.1.3.1.1.5
The FlowMeterEBS parameter contains an integer value that represents the EBS value for the flow meter, in octets. The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

ieee8021PSFPFlowMeterCF 1.3.111.2.802.1.1.31.1.3.1.1.6
The FlowMeterCF parameter contains an integer value that represents the CF value for the flow meter, as an integer value 0 or 1. The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..1  

ieee8021PSFPFlowMeterCM 1.3.111.2.802.1.1.31.1.3.1.1.7
The FlowMeterCM parameter contains an integer value that represents the CM value for the flow meter, as an enumerated value indicating colorBlind(1) or colorAware(2). The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER colorBlind(1), colorAware(2)  

ieee8021PSFPFlowMeterDropOnYellow 1.3.111.2.802.1.1.31.1.3.1.1.8
The FlowMeterDropOnYellow parameter contains a Boolean value that indicates whether yellow frames are dropped (TRUE) or have drop_eligible set to TRUE (FALSE). The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

ieee8021PSFPFlowMeterMarkAllFramesRedEnable 1.3.111.2.802.1.1.31.1.3.1.1.9
The FlowMeterMarkAllFramesRedEnable parameter contains a Boolean value that indicates whether the MarkAllFramesRed function is enabled (TRUE) or disabled (FALSE). The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

ieee8021PSFPFlowMeterMarkAllFramesRed 1.3.111.2.802.1.1.31.1.3.1.1.10
The FlowMeterMarkAllFramesRed parameter contains a Boolean value that indicates whether, if the MarkAllFramesRed function is enabled, all frames are to be discarded (TRUE) or not (FALSE). The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

ieee8021PSFPFlowMeterEntryRowStatus 1.3.111.2.802.1.1.31.1.3.1.1.11
The status of the row. The writable columns in a row cannot be changed if the row is active. All columns MUST have a valid value before a row can be activated.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

ieee8021PSFPStreamParameterTable 1.3.111.2.802.1.1.31.1.4.1
A table that contains per-Bridge component manageable parameters for PSFP. A row in the table exists for each Bridge component. All writable objects in this table must be persistent over power up restart/reboot.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ieee8021PSFPStreamParameterEntry

ieee8021PSFPStreamParameterEntry 1.3.111.2.802.1.1.31.1.4.1.1
A list of objects that contains the manageable parameters for flow meters for a Bridge component.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ieee8021PSFPStreamParameterEntry  

ieee8021PSFPMaxStreamFilterInstances 1.3.111.2.802.1.1.31.1.4.1.1.1
The MaxStreamFilterInstances parameter defines the maximum number of stream filter instances that are supported by this Bridge component.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ieee8021PSFPMaxStreamGateInstances 1.3.111.2.802.1.1.31.1.4.1.1.2
The MaxStreamGateInstances parameter defines the maximum number of stream gate instances that are supported by this Bridge component.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ieee8021PSFPMaxFlowMeterInstances 1.3.111.2.802.1.1.31.1.4.1.1.3
The MaxFlowMeterInstances parameter defines the maximum number of flow meter instances that are supported by this Bridge component.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ieee8021PSFPSupportedListMax 1.3.111.2.802.1.1.31.1.4.1.1.4
The SupportedListMax parameter defines the The maximum value supported by this Bridge component of the AdminControlListLength and OperControlListLength parameters.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ieee8021PSFPCompliances 1.3.111.2.802.1.1.31.2.1
OBJECT IDENTIFIER    

ieee8021PSFPGroups 1.3.111.2.802.1.1.31.2.2
OBJECT IDENTIFIER    

ieee8021PSFPObjectsGroup 1.3.111.2.802.1.1.31.2.2.1
Objects that allow management of PSFP.
Status: current Access: read-only
OBJECT-GROUP    

ieee8021PSFPCompliance 1.3.111.2.802.1.1.31.2.1.1
The compliance statement for devices supporting PSFP. Support of the objects defined in this MIB module also requires support of the IEEE8021-BRIDGE-MIB; the provisions of 17.3.2 apply to implementations claiming support of this MIB.
Status: current Access: read-only
MODULE-COMPLIANCE