IEEE8021-BRIDGE-MIB

File: IEEE8021-BRIDGE-MIB.mib (88789 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
IF-MIB IEEE8021-TC-MIB SNMP-FRAMEWORK-MIB
SNMPv2-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Integer32
Counter64 RowStatus MacAddress
TruthValue TimeInterval MODULE-COMPLIANCE
OBJECT-GROUP ifIndex InterfaceIndexOrZero
ifGeneralInformationGroup ieee802dot1mibs IEEE8021PbbComponentIdentifier
IEEE8021BridgePortNumber IEEE8021PriorityCodePoint IEEE8021BridgePortType
IEEE8021PriorityValue IEEE8021PbbComponentIdentifierOrZero IEEE8021BridgePortNumberOrZero
SnmpAdminString systemGroup

Defined Types

Ieee8021BridgeBaseEntry  
SEQUENCE    
  ieee8021BridgeBaseComponentId IEEE8021PbbComponentIdentifier
  ieee8021BridgeBaseBridgeAddress MacAddress
  ieee8021BridgeBaseNumPorts Integer32
  ieee8021BridgeBaseComponentType INTEGER
  ieee8021BridgeBaseDeviceCapabilities BITS
  ieee8021BridgeBaseTrafficClassesEnabled TruthValue
  ieee8021BridgeBaseMmrpEnabledStatus TruthValue
  ieee8021BridgeBaseRowStatus RowStatus

Ieee8021BridgeBasePortEntry  
SEQUENCE    
  ieee8021BridgeBasePortComponentId IEEE8021PbbComponentIdentifier
  ieee8021BridgeBasePort IEEE8021BridgePortNumber
  ieee8021BridgeBasePortIfIndex InterfaceIndexOrZero
  ieee8021BridgeBasePortDelayExceededDiscards Counter64
  ieee8021BridgeBasePortMtuExceededDiscards Counter64
  ieee8021BridgeBasePortCapabilities BITS
  ieee8021BridgeBasePortTypeCapabilities BITS
  ieee8021BridgeBasePortType IEEE8021BridgePortType
  ieee8021BridgeBasePortExternal TruthValue
  ieee8021BridgeBasePortAdminPointToPoint INTEGER
  ieee8021BridgeBasePortOperPointToPoint TruthValue
  ieee8021BridgeBasePortName SnmpAdminString

Ieee8021BridgeBaseIfToPortEntry  
SEQUENCE    
  ieee8021BridgeBaseIfIndexComponentId IEEE8021PbbComponentIdentifier
  ieee8021BridgeBaseIfIndexPort IEEE8021BridgePortNumber

Ieee8021BridgePhyPortEntry  
SEQUENCE    
  ieee8021BridgePhyPort IEEE8021BridgePortNumber
  ieee8021BridgePhyPortIfIndex InterfaceIndexOrZero
  ieee8021BridgePhyMacAddress MacAddress
  ieee8021BridgePhyPortToComponentId IEEE8021PbbComponentIdentifierOrZero
  ieee8021BridgePhyPortToInternalPort IEEE8021BridgePortNumberOrZero

Ieee8021BridgeTpPortEntry  
SEQUENCE    
  ieee8021BridgeTpPortComponentId IEEE8021PbbComponentIdentifier
  ieee8021BridgeTpPort IEEE8021BridgePortNumber
  ieee8021BridgeTpPortMaxInfo Integer32
  ieee8021BridgeTpPortInFrames Counter64
  ieee8021BridgeTpPortOutFrames Counter64
  ieee8021BridgeTpPortInDiscards Counter64

Ieee8021BridgePortPriorityEntry  
SEQUENCE    
  ieee8021BridgePortDefaultUserPriority IEEE8021PriorityValue
  ieee8021BridgePortNumTrafficClasses Integer32
  ieee8021BridgePortPriorityCodePointSelection IEEE8021PriorityCodePoint
  ieee8021BridgePortUseDEI TruthValue
  ieee8021BridgePortRequireDropEncoding TruthValue
  ieee8021BridgePortServiceAccessPrioritySelection TruthValue

Ieee8021BridgeUserPriorityRegenEntry  
SEQUENCE    
  ieee8021BridgeUserPriority IEEE8021PriorityValue
  ieee8021BridgeRegenUserPriority IEEE8021PriorityValue

Ieee8021BridgeTrafficClassEntry  
SEQUENCE    
  ieee8021BridgeTrafficClassPriority IEEE8021PriorityValue
  ieee8021BridgeTrafficClass Integer32

Ieee8021BridgePortOutboundAccessPriorityEntry  
SEQUENCE    
  ieee8021BridgePortOutboundAccessPriority IEEE8021PriorityValue

Ieee8021BridgePortDecodingEntry  
SEQUENCE    
  ieee8021BridgePortDecodingComponentId IEEE8021PbbComponentIdentifier
  ieee8021BridgePortDecodingPortNum IEEE8021BridgePortNumber
  ieee8021BridgePortDecodingPriorityCodePointRow IEEE8021PriorityCodePoint
  ieee8021BridgePortDecodingPriorityCodePoint Integer32
  ieee8021BridgePortDecodingPriority IEEE8021PriorityValue
  ieee8021BridgePortDecodingDropEligible TruthValue

Ieee8021BridgePortEncodingEntry  
SEQUENCE    
  ieee8021BridgePortEncodingComponentId IEEE8021PbbComponentIdentifier
  ieee8021BridgePortEncodingPortNum IEEE8021BridgePortNumber
  ieee8021BridgePortEncodingPriorityCodePointRow IEEE8021PriorityCodePoint
  ieee8021BridgePortEncodingPriorityCodePoint Integer32
  ieee8021BridgePortEncodingDropEligible TruthValue
  ieee8021BridgePortEncodingPriority IEEE8021PriorityValue

Ieee8021BridgeServiceAccessPriorityEntry  
SEQUENCE    
  ieee8021BridgeServiceAccessPriorityComponentId IEEE8021PbbComponentIdentifier
  ieee8021BridgeServiceAccessPriorityPortNum IEEE8021BridgePortNumber
  ieee8021BridgeServiceAccessPriorityReceived IEEE8021PriorityValue
  ieee8021BridgeServiceAccessPriorityValue IEEE8021PriorityValue

Ieee8021BridgePortMrpEntry  
SEQUENCE    
  ieee8021BridgePortMrpJoinTime TimeInterval
  ieee8021BridgePortMrpLeaveTime TimeInterval
  ieee8021BridgePortMrpLeaveAllTime TimeInterval

Ieee8021BridgePortMmrpEntry  
SEQUENCE    
  ieee8021BridgePortMmrpEnabledStatus TruthValue
  ieee8021BridgePortMmrpFailedRegistrations Counter64
  ieee8021BridgePortMmrpLastPduOrigin MacAddress
  ieee8021BridgePortRestrictedGroupRegistration TruthValue

Ieee8021BridgeILanIfEntry  
SEQUENCE    
  ieee8021BridgeILanIfRowStatus RowStatus

Ieee8021BridgeDot1dPortEntry  
SEQUENCE    
  ieee8021BridgeDot1dPortRowStatus RowStatus

Defined Values

ieee8021BridgeMib 1.3.111.2.802.1.1.2
The Bridge MIB module for managing devices that support IEEE 802.1D. This MIB module is derived from the IETF BRIDGE-MIB, RFC 4188. Unless otherwise indicated, the references in this MIB module are to IEEE Std 802.1Q-2011. Copyright (C) IEEE. This version of this MIB module is part of IEEE802.1Q; see the draft itself for full legal notices.
MODULE-IDENTITY    

ieee8021BridgeNotifications 1.3.111.2.802.1.1.2.0
OBJECT IDENTIFIER    

ieee8021BridgeObjects 1.3.111.2.802.1.1.2.1
OBJECT IDENTIFIER    

ieee8021BridgeConformance 1.3.111.2.802.1.1.2.2
OBJECT IDENTIFIER    

ieee8021BridgeBase 1.3.111.2.802.1.1.2.1.1
OBJECT IDENTIFIER    

ieee8021BridgeTp 1.3.111.2.802.1.1.2.1.2
OBJECT IDENTIFIER    

ieee8021BridgePriority 1.3.111.2.802.1.1.2.1.3
OBJECT IDENTIFIER    

ieee8021BridgeMrp 1.3.111.2.802.1.1.2.1.4
OBJECT IDENTIFIER    

ieee8021BridgeMmrp 1.3.111.2.802.1.1.2.1.5
OBJECT IDENTIFIER    

ieee8021BridgeInternalLan 1.3.111.2.802.1.1.2.1.6
OBJECT IDENTIFIER    

ieee8021BridgeDot1d 1.3.111.2.802.1.1.2.1.7
OBJECT IDENTIFIER    

ieee8021BridgeBaseTable 1.3.111.2.802.1.1.2.1.1.1
A table that contains generic information about every bridge component. All writable objects in this table MUST be persistent over power up restart/reboot.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ieee8021BridgeBaseEntry

ieee8021BridgeBaseEntry 1.3.111.2.802.1.1.2.1.1.1.1
A list of objects containing information for each bridge component.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ieee8021BridgeBaseEntry  

ieee8021BridgeBaseComponentId 1.3.111.2.802.1.1.2.1.1.1.1.1
The component identifier is used to distinguish between the multiple virtual bridge instances within a PBB. In simple situations where there is only a single component the default value is 1.
Status: current Access: not-accessible
OBJECT-TYPE    
  IEEE8021PbbComponentIdentifier  

ieee8021BridgeBaseBridgeAddress 1.3.111.2.802.1.1.2.1.1.1.1.2
The MAC address used by this bridge when it is referred to in a unique fashion. It is recommended that this be the numerically smallest MAC address of all ports that belong to this bridge. However, it is only required to be unique. When concatenated with ieee8021SpanningTreePriority, a unique BridgeIdentifier is formed, which is used in the Spanning Tree Protocol. This object may not be modified while the corresponding instance of ieee8021BridgeBaseRowStatus is active(1). The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  MacAddress  

ieee8021BridgeBaseNumPorts 1.3.111.2.802.1.1.2.1.1.1.1.3
The number of ports controlled by this bridging entity.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ieee8021BridgeBaseComponentType 1.3.111.2.802.1.1.2.1.1.1.1.4
Indicates the component type(s) of this bridge. The following component types are possible: iComponent(1) - An S-VLAN component of a Backbone Edge Bridge which performs encapsulation of customer frames. bComponent(2) - An S-VLAN component of a Backbone Edge Bridge which bundles backbone service instances into B-VLANs. cVlanComponent(3) - A C-VLAN component of an enterprise VLAN bridge or of a Provider Bridge used to process C-tagged frames. sVlanComponent(4) - An S-VLAN component of a Provider Bridge. dBridgeComponent(5) - A VLAN unaware component of an 802.1D bridge. erComponent (6) - An Edge Relay component of an EVB Station. tComponent (7) - A TPMR component in a Backbone Edge Bridge. This object may not be modified while the corresponding instance of ieee8021BridgeBaseRowStatus is active(1). The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER iComponent(1), bComponent(2), cVlanComponent(3), sVlanComponent(4), dBridgeComponent(5), erComponent(6), tComponent(7)  

ieee8021BridgeBaseDeviceCapabilities 1.3.111.2.802.1.1.2.1.1.1.1.5
Indicates the optional parts of IEEE 802.1D and 802.1Q that are implemented by this device and are manageable through this MIB. Capabilities that are allowed on a per-port basis are indicated in ieee8021BridgeBasePortCapabilities. dot1dExtendedFilteringServices(0), -- can perform filtering of -- individual multicast addresses -- controlled by MMRP. dot1dTrafficClasses(1), -- can map user priority to -- multiple traffic classes. dot1qStaticEntryIndividualPort(2), -- dot1qStaticUnicastReceivePort & -- dot1qStaticMulticastReceivePort -- can represent non-zero entries. dot1qIVLCapable(3), -- Independent VLAN Learning (IVL). dot1qSVLCapable(4), -- Shared VLAN Learning (SVL). dot1qHybridCapable(5), -- both IVL & SVL simultaneously. dot1qConfigurablePvidTagging(6), -- whether the implementation -- supports the ability to -- override the default PVID -- setting and its egress status -- (VLAN-Tagged or Untagged) on -- each port. dot1dLocalVlanCapable(7) -- can support multiple local -- bridges, outside of the scope -- of 802.1Q defined VLANs. This object may not be modified while the corresponding instance of ieee8021BridgeBaseRowStatus is active(1). The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  BITS dot1dExtendedFilteringServices(0), dot1dTrafficClasses(1), dot1qStaticEntryIndividualPort(2), dot1qIVLCapable(3), dot1qSVLCapable(4), dot1qHybridCapable(5), dot1qConfigurablePvidTagging(6), dot1dLocalVlanCapable(7)  

ieee8021BridgeBaseTrafficClassesEnabled 1.3.111.2.802.1.1.2.1.1.1.1.6
The value true(1) indicates that Traffic Classes are enabled on this bridge. When false(2), the bridge operates with a single priority level for all traffic. This object may be modified while the corresponding instance of ieee8021BridgeBaseRowStatus is active(1). The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

ieee8021BridgeBaseMmrpEnabledStatus 1.3.111.2.802.1.1.2.1.1.1.1.7
The administrative status requested by management for MMRP. The value true(1) indicates that MMRP should be enabled on this device, in all VLANs, on all ports for which it has not been specifically disabled. When false(2), MMRP is disabled, in all VLANs and on all ports, and all MMRP packets will be forwarded transparently. This object affects both Applicant and Registrar state machines. A transition from false(2) to true(1) will cause a reset of all MMRP state machines on all ports. This object may be modified while the corresponding instance of ieee8021BridgeBaseRowStatus is active(1). The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

ieee8021BridgeBaseRowStatus 1.3.111.2.802.1.1.2.1.1.1.1.8
The object indicates the status of an entry, and is used to create/delete entries. The following objects MUST be set prior to making a new entry active: ieee8021BridgeBaseBridgeAddress ieee8021BridgeBaseComponentType ieee8021BridgeBaseDeviceCapabilities It is recommended that these three objects not be allowed to be modified while the corresponding instance of ieee8021BridgeBaseRowStatus object is active(1). The following objects are not required to be set before making a new entry active (they will take their defaults), and they also may be modified while the corresponding instance of this object is active(1): ieee8021BridgeBaseTrafficClassesEnabled ieee8021BridgeBaseMmrpEnabledStatus The value of this object and all corresponding instances of other objects in this table MUST be retained across reinitializations of the management system.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

ieee8021BridgeBasePortTable 1.3.111.2.802.1.1.2.1.1.4
A table that contains generic information about every port that is associated with this bridge. Transparent, and source-route ports are included.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ieee8021BridgeBasePortEntry

ieee8021BridgeBasePortEntry 1.3.111.2.802.1.1.2.1.1.4.1
A list of objects containing information for each port of the bridge.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ieee8021BridgeBasePortEntry  

ieee8021BridgeBasePortComponentId 1.3.111.2.802.1.1.2.1.1.4.1.1
The component identifier is used to distinguish between the multiple virtual bridge instances within a PBB. In simple situations where there is only a single component the default value is 1.
Status: current Access: not-accessible
OBJECT-TYPE    
  IEEE8021PbbComponentIdentifier  

ieee8021BridgeBasePort 1.3.111.2.802.1.1.2.1.1.4.1.2
The port number of the port for which this entry contains bridge management information.
Status: current Access: not-accessible
OBJECT-TYPE    
  IEEE8021BridgePortNumber  

ieee8021BridgeBasePortIfIndex 1.3.111.2.802.1.1.2.1.1.4.1.3
The value of the instance of the IfIndex object, defined in the IF-MIB, for the interface corresponding to this port, or the value 0 if the port has not been bound to an underlying frame source and sink. It is an implementation specific decision as to whether this object may be modified if it has been created or if 0 is a legal value. The underlying IfEntry indexed by this column MUST be persistent across reinitializations of the management system.
Status: current Access: read-write
OBJECT-TYPE    
  InterfaceIndexOrZero  

ieee8021BridgeBasePortDelayExceededDiscards 1.3.111.2.802.1.1.2.1.1.4.1.4
The number of frames discarded by this port due to excessive transit delay through the bridge. It is incremented by both transparent and source route bridges. Discontinuities in the value of the counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime object of the associated interface (if any).
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

ieee8021BridgeBasePortMtuExceededDiscards 1.3.111.2.802.1.1.2.1.1.4.1.5
The number of frames discarded by this port due to an excessive size. It is incremented by both transparent and source route bridges. Discontinuities in the value of the counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime object of the associated interface (if any).
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

ieee8021BridgeBasePortCapabilities 1.3.111.2.802.1.1.2.1.1.4.1.6
Indicates the parts of IEEE 802.1D and 802.1Q that are optional on a per-port basis, that are implemented by this device, and that are manageable through this MIB. dot1qDot1qTagging(0), -- supports 802.1Q VLAN tagging of -- frames and MVRP. dot1qConfigurableAcceptableFrameTypes(1), -- allows modified values of -- dot1qPortAcceptableFrameTypes. dot1qIngressFiltering(2) -- supports the discarding of any -- frame received on a Port whose -- VLAN classification does not -- include that Port in its Member -- set.
Status: current Access: read-only
OBJECT-TYPE    
  BITS dot1qDot1qTagging(0), dot1qConfigurableAcceptableFrameTypes(1), dot1qIngressFiltering(2)  

ieee8021BridgeBasePortTypeCapabilities 1.3.111.2.802.1.1.2.1.1.4.1.7
Indicates the capabilities of this port. The corresponding instance of ieee8021BridgeBasePortType can potentially take any of the values for which the corresponding bit in this object is 1. The possible port types are as follows: customerVlanPort(0) - Indicates the port can be a C-tag aware port of an enterprise VLAN aware bridge. providerNetworkPort(1) - Indicates the port can be an S-tag aware port of a Provider Bridge or Backbone Edge Bridge used for connections within a PBN or PBBN. customerNetworkPort(2) - Indicates the port can be an S-tag aware port of a Provider Bridge or Backbone Edge Bridge used for connections to the exterior of a PBN or PBBN. customerEdgePort(3) - Indicates the port can be a C-tag aware port of a Provider Bridge used for connections to the exterior of a PBN or PBBN. customerBackbonePort(4) - Indicates the port can be a I-tag aware port of a Backbone Edge Bridge's B-component. virtualInstancePort(5) - Indicates the port can be a virtual S-tag aware port within a Backbone Edge Bridge's I-component which is responsible for handling S-tagged traffic for a specific backbone service instance. dBridgePort(6) - Indicates the port can be a VLAN-unaware member of an 802.1D bridge. remoteCustomerAccessPort(7) - Indicates the port can be an S-tag aware port of a Provider Bridge capable of providing Remote Customer Service Interfaces. stationFacingBridgePort(8) - Indicates the station-facing Bridge Port in a EVB Bridge. uplinkAccessPort(9) - Indicates the uplink access port in an EVB Bridge or EVB station. uplinkRelayPort (10) - Indicates the uplink relay port in an EVB station.
Status: current Access: read-only
OBJECT-TYPE    
  BITS customerVlanPort(0), providerNetworkPort(1), customerNetworkPort(2), customerEdgePort(3), customerBackbonePort(4), virtualInstancePort(5), dBridgePort(6), remoteCustomerAccessPort(7), stationFacingBridgePort(8), uplinkAccessPort(9), uplinkRelayPort(10)  

ieee8021BridgeBasePortType 1.3.111.2.802.1.1.2.1.1.4.1.8
The port type. This value MUST be persistent over power up restart/reboot.
Status: current Access: read-only
OBJECT-TYPE    
  IEEE8021BridgePortType  

ieee8021BridgeBasePortExternal 1.3.111.2.802.1.1.2.1.1.4.1.9
A boolean indicating whether the port is external. A value of true(1) means the port is external. A value of false(2) means the port is internal.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ieee8021BridgeBasePortAdminPointToPoint 1.3.111.2.802.1.1.2.1.1.4.1.10
For a port running spanning tree, this object represents the administrative point-to-point status of the LAN segment attached to this port, using the enumeration values of 6.4.3. A value of forceTrue(1) indicates that this port should always be treated as if it is connected to a point-to-point link. A value of forceFalse(2) indicates that this port should be treated as having a shared media connection. A value of auto(3) indicates that this port is considered to have a point-to-point link if it is an Aggregator and all of its members are aggregatable, or if the MAC entity is configured for full duplex operation, either through auto-negotiation or by management means. Manipulating this object changes the underlying adminPointToPointMAC. For a VIP, the adminPointToPointMAC parameter controls the mechanism by which the Default Backbone Destination parameter for the VIP is determined. For a backbone service instance that includes only 2 VIPs, the value may be set to forceTrue(1) which permits dynamic learning of the Default Backbone Destination parameter. For a backbone service instance that includes more than 2 VIPs, the value MUST be set to ForceFalse(2) or auto(3). When this object is set to forceTrue(1) for a VIP, the Default Backbone Destination parameter is modified by the subsequent M_UNITDATA.indications as specified in 6.10.1 (and described in 26.4.1). Whenever the parameter is set to forceFalse(2) or auto(3), the value for the Default Backbone Destination parameter is set to the Backbone Service Instance Group Address for the VIP-ISID. The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER forceTrue(1), forceFalse(2), auto(3)  

ieee8021BridgeBasePortOperPointToPoint 1.3.111.2.802.1.1.2.1.1.4.1.11
For a port running spanning tree, this object represents the operational point-to-point status of the LAN segment attached to this port. It indicates whether a port is considered to have a point-to-point connection. If adminPointToPointMAC is set to auto(2), then the value of operPointToPointMAC is determined in accordance with the specific procedures defined for the MAC entity concerned, as defined in 6.7. The value is determined dynamically; that is, it is re-evaluated whenever the value of adminPointToPointMAC changes, and whenever the specific procedures defined for the MAC entity evaluate a change in its point-to-point status. For a VIP, this object simply reflects the value of the corresponding instance of ieee8021BridgeBasePortAdminPointToPoint. The value will be true(1) if that object is forceTrue(1), and the value will be false(2) if the value of that object is either forceFalse(2) or auto(3).
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

ieee8021BridgeBasePortName 1.3.111.2.802.1.1.2.1.1.4.1.12
A text string of up to 32 characters, of locally determined significance.
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString  

ieee8021BridgeBaseIfToPortTable 1.3.111.2.802.1.1.2.1.1.5
A table that contains generic information about every ifIndex that is associated with this bridge.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ieee8021BridgeBaseIfToPortEntry

ieee8021BridgeBaseIfToPortEntry 1.3.111.2.802.1.1.2.1.1.5.1
A list of objects containing information for each ifIndex of the bridge.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ieee8021BridgeBaseIfToPortEntry  

ieee8021BridgeBaseIfIndexComponentId 1.3.111.2.802.1.1.2.1.1.5.1.1
The component ID for this ifIndex.
Status: current Access: read-only
OBJECT-TYPE    
  IEEE8021PbbComponentIdentifier  

ieee8021BridgeBaseIfIndexPort 1.3.111.2.802.1.1.2.1.1.5.1.2
The port for this ifIndex.
Status: current Access: read-only
OBJECT-TYPE    
  IEEE8021BridgePortNumber  

ieee8021BridgePhyPortTable 1.3.111.2.802.1.1.2.1.1.6
A table that contains ISS port number to bridge componentID and port number mapping.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ieee8021BridgePhyPortEntry

ieee8021BridgePhyPortEntry 1.3.111.2.802.1.1.2.1.1.6.1
A list of objects containing mapping for ISS port numbers to bridge componentID and port numbers
Status: current Access: not-accessible
OBJECT-TYPE    
  Ieee8021BridgePhyPortEntry  

ieee8021BridgePhyPort 1.3.111.2.802.1.1.2.1.1.6.1.1
The ISS port.
Status: current Access: not-accessible
OBJECT-TYPE    
  IEEE8021BridgePortNumber  

ieee8021BridgePhyPortIfIndex 1.3.111.2.802.1.1.2.1.1.6.1.2
The value of the instance of the IfIndex object, defined in the IF-MIB, for the interface corresponding to this port, or the value 0 if the port has not been bound to an underlying frame source and sink. The underlying IfEntry indexed by this column MUST be persistent across reinitializations of the management system.
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndexOrZero  

ieee8021BridgePhyMacAddress 1.3.111.2.802.1.1.2.1.1.6.1.3
The MAC address
Status: current Access: read-only
OBJECT-TYPE    
  MacAddress  

ieee8021BridgePhyPortToComponentId 1.3.111.2.802.1.1.2.1.1.6.1.4
The component ID that this ISS port belongs to.
Status: current Access: read-only
OBJECT-TYPE    
  IEEE8021PbbComponentIdentifierOrZero  

ieee8021BridgePhyPortToInternalPort 1.3.111.2.802.1.1.2.1.1.6.1.5
The port number to which this ISS port maps to.
Status: current Access: read-only
OBJECT-TYPE    
  IEEE8021BridgePortNumberOrZero  

ieee8021BridgeTpPortTable 1.3.111.2.802.1.1.2.1.2.1
A table that contains information about every port that is associated with this transparent bridge.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ieee8021BridgeTpPortEntry

ieee8021BridgeTpPortEntry 1.3.111.2.802.1.1.2.1.2.1.1
A list of objects containing information for each port of a transparent bridge.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ieee8021BridgeTpPortEntry  

ieee8021BridgeTpPortComponentId 1.3.111.2.802.1.1.2.1.2.1.1.1
The component identifier is used to distinguish between the multiple virtual bridge instances within a PBB. In simple situations where there is only a single component the default value is 1.
Status: current Access: not-accessible
OBJECT-TYPE    
  IEEE8021PbbComponentIdentifier  

ieee8021BridgeTpPort 1.3.111.2.802.1.1.2.1.2.1.1.2
The port number of the port for which this entry contains Transparent bridging management information.
Status: current Access: not-accessible
OBJECT-TYPE    
  IEEE8021BridgePortNumber  

ieee8021BridgeTpPortMaxInfo 1.3.111.2.802.1.1.2.1.2.1.1.3
The maximum size of the INFO (non-MAC) field that this port will receive or transmit.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ieee8021BridgeTpPortInFrames 1.3.111.2.802.1.1.2.1.2.1.1.4
The number of frames that have been received by this port from its segment. Note that a frame received on the interface corresponding to this port is only counted by this object if and only if it is for a protocol being processed by the local bridging function, including bridge management frames. Discontinuities in the value of the counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime object of the associated interface (if any).
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

ieee8021BridgeTpPortOutFrames 1.3.111.2.802.1.1.2.1.2.1.1.5
The number of frames that have been transmitted by this port to its segment. Note that a frame transmitted on the interface corresponding to this port is only counted by this object if and only if it is for a protocol being processed by the local bridging function, including bridge management frames. Discontinuities in the value of the counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime object of the associated interface (if any).
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

ieee8021BridgeTpPortInDiscards 1.3.111.2.802.1.1.2.1.2.1.1.6
Count of received valid frames that were discarded (i.e., filtered) by the Forwarding Process. Discontinuities in the value of the counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime object of the associated interface (if any).
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

ieee8021BridgePortPriorityTable 1.3.111.2.802.1.1.2.1.3.1
A table that contains information about every port that is associated with this transparent bridge.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ieee8021BridgePortPriorityEntry

ieee8021BridgePortPriorityEntry 1.3.111.2.802.1.1.2.1.3.1.1
A list of Default User Priorities for each port of a transparent bridge. This is indexed by ieee8021BridgeBasePortComponentId and ieee8021BridgeBasePort.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ieee8021BridgePortPriorityEntry  

ieee8021BridgePortDefaultUserPriority 1.3.111.2.802.1.1.2.1.3.1.1.1
The default ingress User Priority for this port. This only has effect on media, such as Ethernet, that do not support native User Priority. The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-write
OBJECT-TYPE    
  IEEE8021PriorityValue  

ieee8021BridgePortNumTrafficClasses 1.3.111.2.802.1.1.2.1.3.1.1.2
The number of egress traffic classes supported on this port. This object may optionally be read-only. The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..8  

ieee8021BridgePortPriorityCodePointSelection 1.3.111.2.802.1.1.2.1.3.1.1.3
This object identifies the rows in the PCP encoding and decoding tables that are used to remark frames on this port if this remarking is enabled.
Status: current Access: read-write
OBJECT-TYPE    
  IEEE8021PriorityCodePoint  

ieee8021BridgePortUseDEI 1.3.111.2.802.1.1.2.1.3.1.1.4
If the Use_DEI is set to true(1) for the Port then the drop_eligible parameter is encoded in the DEI of transmitted frames, and the drop_eligible parameter shall be true(1) for a received frame if the DEI is set in the VLAN tag or the Priority Code Point Decoding Table indicates drop_eligible True for the received PCP value. If the Use_DEI parameter is false(2), the DEI shall be transmitted as zero and ignored on receipt. The default value of the Use_DEI parameter is false(2).
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

ieee8021BridgePortRequireDropEncoding 1.3.111.2.802.1.1.2.1.3.1.1.5
If a Bridge supports encoding or decoding of drop_eligible from the PCP field of a VLAN tag (6.7.3) on any of its Ports, then it shall implement a Boolean parameter Require Drop Encoding on each of its Ports with default value false(2). If Require Drop Encoding is True and the Bridge Port cannot encode particular priorities with drop_eligible, then frames queued with those priorities and drop_eligible true(1) shall be discarded and not transmitted.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

ieee8021BridgePortServiceAccessPrioritySelection 1.3.111.2.802.1.1.2.1.3.1.1.6
Indication of whether the Service Access Priority Selection function is supported on the Customer Bridge Port to request priority handling of the frame from a Port-based service interface.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

ieee8021BridgeUserPriorityRegenTable 1.3.111.2.802.1.1.2.1.3.2
A list of Regenerated User Priorities for each received User Priority on each port of a bridge. The Regenerated User Priority value may be used to index the Traffic Class Table for each input port. This only has effect on media that support native User Priority. The default values for Regenerated User Priorities are the same as the User Priorities.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ieee8021BridgeUserPriorityRegenEntry

ieee8021BridgeUserPriorityRegenEntry 1.3.111.2.802.1.1.2.1.3.2.1
A mapping of incoming User Priority to a Regenerated User Priority.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ieee8021BridgeUserPriorityRegenEntry  

ieee8021BridgeUserPriority 1.3.111.2.802.1.1.2.1.3.2.1.1
The User Priority for a frame received on this port.
Status: current Access: not-accessible
OBJECT-TYPE    
  IEEE8021PriorityValue  

ieee8021BridgeRegenUserPriority 1.3.111.2.802.1.1.2.1.3.2.1.2
The Regenerated User Priority that the incoming User Priority is mapped to for this port. The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-write
OBJECT-TYPE    
  IEEE8021PriorityValue  

ieee8021BridgeTrafficClassTable 1.3.111.2.802.1.1.2.1.3.3
A table mapping evaluated User Priority to Traffic Class, for forwarding by the bridge. Traffic class is a number in the range (0..(ieee8021BridgePortNumTrafficClasses-1)).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ieee8021BridgeTrafficClassEntry

ieee8021BridgeTrafficClassEntry 1.3.111.2.802.1.1.2.1.3.3.1
User Priority to Traffic Class mapping.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ieee8021BridgeTrafficClassEntry  

ieee8021BridgeTrafficClassPriority 1.3.111.2.802.1.1.2.1.3.3.1.1
The Priority value determined for the received frame. This value is equivalent to the priority indicated in the tagged frame received, or one of the evaluated priorities, determined according to the media-type. For untagged frames received from Ethernet media, this value is equal to the ieee8021BridgePortDefaultUserPriority value for the ingress port. For untagged frames received from non-Ethernet media, this value is equal to the ieee8021BridgeRegenUserPriority value for the ingress port and media-specific user priority.
Status: current Access: not-accessible
OBJECT-TYPE    
  IEEE8021PriorityValue  

ieee8021BridgeTrafficClass 1.3.111.2.802.1.1.2.1.3.3.1.2
The Traffic Class the received frame is mapped to. The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..7  

ieee8021BridgePortOutboundAccessPriorityTable 1.3.111.2.802.1.1.2.1.3.4
A table mapping Regenerated User Priority to Outbound Access Priority. This is a fixed mapping for all port types, with three options for 802.17 RPR.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ieee8021BridgePortOutboundAccessPriorityEntry

ieee8021BridgePortOutboundAccessPriorityEntry 1.3.111.2.802.1.1.2.1.3.4.1
Regenerated User Priority to Outbound Access Priority mapping.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ieee8021BridgePortOutboundAccessPriorityEntry  

ieee8021BridgePortOutboundAccessPriority 1.3.111.2.802.1.1.2.1.3.4.1.1
The Outbound Access Priority the received frame is mapped to.
Status: current Access: read-only
OBJECT-TYPE    
  IEEE8021PriorityValue  

ieee8021BridgePortDecodingTable 1.3.111.2.802.1.1.2.1.3.5
A table that contains information about Priority Code Point Decoding Table for a Port of a provider bridge. Alternative values for each table are specified as rows in Table 6-4 (6.7.3), with each alternative labeled by the number of distinct priorities that can be communicated, and the number of these for which drop precedence can be communicated. All writable objects in this table MUST be persistent over power up restart/reboot.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ieee8021BridgePortDecodingEntry

ieee8021BridgePortDecodingEntry 1.3.111.2.802.1.1.2.1.3.5.1
A list of objects containing Priority Code Point Decoding information for a port of a provider bridge.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ieee8021BridgePortDecodingEntry  

ieee8021BridgePortDecodingComponentId 1.3.111.2.802.1.1.2.1.3.5.1.1
The component identifier is used to distinguish between the multiple virtual bridge instances within a PBB. In simple situations where there is only a single component the default value is 1.
Status: current Access: not-accessible
OBJECT-TYPE    
  IEEE8021PbbComponentIdentifier  

ieee8021BridgePortDecodingPortNum 1.3.111.2.802.1.1.2.1.3.5.1.2
A unique identifier of a port controlled by this VLAN bridging entity.
Status: current Access: not-accessible
OBJECT-TYPE    
  IEEE8021BridgePortNumber  

ieee8021BridgePortDecodingPriorityCodePointRow 1.3.111.2.802.1.1.2.1.3.5.1.3
The specific row in Table 6-3 (6.7.3) indicating the PCP.
Status: current Access: not-accessible
OBJECT-TYPE    
  IEEE8021PriorityCodePoint  

ieee8021BridgePortDecodingPriorityCodePoint 1.3.111.2.802.1.1.2.1.3.5.1.4
The specific PCP value in Table 6-3 (6.7.3).
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..7  

ieee8021BridgePortDecodingPriority 1.3.111.2.802.1.1.2.1.3.5.1.5
The specific priority value in Table 6-3 (6.7.3).
Status: current Access: read-write
OBJECT-TYPE    
  IEEE8021PriorityValue  

ieee8021BridgePortDecodingDropEligible 1.3.111.2.802.1.1.2.1.3.5.1.6
The drop eligibility value in Table 6-3 (6.7.3).
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

ieee8021BridgePortEncodingTable 1.3.111.2.802.1.1.2.1.3.6
A table that contains information about Priority Code Point Decoding Table for a Port of a provider bridge. Alternative values for each table are specified as rows in Table 6-3 (6.7.3), with each alternative labeled by the number of distinct priorities that can be communicated, and the number of these for which drop precedence can be communicated. All writable objects in this table MUST be persistent over power up restart/reboot.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ieee8021BridgePortEncodingEntry

ieee8021BridgePortEncodingEntry 1.3.111.2.802.1.1.2.1.3.6.1
A list of objects containing Priority Code Point Encoding information for a port of a provider bridge.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ieee8021BridgePortEncodingEntry  

ieee8021BridgePortEncodingComponentId 1.3.111.2.802.1.1.2.1.3.6.1.1
The component identifier is used to distinguish between the multiple virtual bridge instances within a PBB. In simple situations where there is only a single component the default value is 1.
Status: current Access: not-accessible
OBJECT-TYPE    
  IEEE8021PbbComponentIdentifier  

ieee8021BridgePortEncodingPortNum 1.3.111.2.802.1.1.2.1.3.6.1.2
A unique identifier of a port controlled by this VLAN bridging entity.
Status: current Access: not-accessible
OBJECT-TYPE    
  IEEE8021BridgePortNumber  

ieee8021BridgePortEncodingPriorityCodePointRow 1.3.111.2.802.1.1.2.1.3.6.1.3
The specific row in Table 6-3 (6.7.3)indicating the PCP row. (i.e. 8P0D, 7P1D, 6P2D, 5P3D)
Status: current Access: not-accessible
OBJECT-TYPE    
  IEEE8021PriorityCodePoint  

ieee8021BridgePortEncodingPriorityCodePoint 1.3.111.2.802.1.1.2.1.3.6.1.4
The specific row in Table 6-3 (6.7.3) indicating the PCP. (i.e., 0,1,2,3,4,5,6,7).
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..7  

ieee8021BridgePortEncodingDropEligible 1.3.111.2.802.1.1.2.1.3.6.1.5
The specific row in Table 6-3 (6.7.3) indicating the drop eligibility. A value of true(1) means eligible for drop.
Status: current Access: not-accessible
OBJECT-TYPE    
  TruthValue  

ieee8021BridgePortEncodingPriority 1.3.111.2.802.1.1.2.1.3.6.1.6
The encoding priority in Table 6-3 (6.7.3).
Status: current Access: read-write
OBJECT-TYPE    
  IEEE8021PriorityValue  

ieee8021BridgeServiceAccessPriorityTable 1.3.111.2.802.1.1.2.1.3.7
A table that contains information about the Service Access Priority Selection function for a provider bridge. The use of this table enables a mechanism for a Customer Bridge attached to a Provider Bridged Network to request priority handling of frames. All writable objects in this table MUST be persistent over power up restart/reboot.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ieee8021BridgeServiceAccessPriorityEntry

ieee8021BridgeServiceAccessPriorityEntry 1.3.111.2.802.1.1.2.1.3.7.1
A list of objects containing information about the Service Access Priority Selection function for a provider bridge.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ieee8021BridgeServiceAccessPriorityEntry  

ieee8021BridgeServiceAccessPriorityComponentId 1.3.111.2.802.1.1.2.1.3.7.1.1
The component identifier is used to distinguish between the multiple virtual bridge instances within a PBB. In simple situations where there is only a single component the default value is 1.
Status: current Access: not-accessible
OBJECT-TYPE    
  IEEE8021PbbComponentIdentifier  

ieee8021BridgeServiceAccessPriorityPortNum 1.3.111.2.802.1.1.2.1.3.7.1.2
A unique identifier of a port controlled by this VLAN bridging entity.
Status: current Access: not-accessible
OBJECT-TYPE    
  IEEE8021BridgePortNumber  

ieee8021BridgeServiceAccessPriorityReceived 1.3.111.2.802.1.1.2.1.3.7.1.3
The default received priority value in Table 6-3 (6.7.3). (i.e., 0,1,2,3,4,5,6,7)
Status: current Access: not-accessible
OBJECT-TYPE    
  IEEE8021PriorityValue  

ieee8021BridgeServiceAccessPriorityValue 1.3.111.2.802.1.1.2.1.3.7.1.4
The regenerated priority value in Table 6-3 (6.7.3). (i.e., 0,1,2,3,4,5,6,7)
Status: current Access: read-write
OBJECT-TYPE    
  IEEE8021PriorityValue  

ieee8021BridgePortMrpTable 1.3.111.2.802.1.1.2.1.4.1
A table of MRP control information about every bridge port. This is indexed by ieee8021BridgeBasePortComponentId and ieee8021BridgeBasePort.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ieee8021BridgePortMrpEntry

ieee8021BridgePortMrpEntry 1.3.111.2.802.1.1.2.1.4.1.1
MRP control information for a bridge port.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ieee8021BridgePortMrpEntry  

ieee8021BridgePortMrpJoinTime 1.3.111.2.802.1.1.2.1.4.1.1.1
The MRP Join time, in centiseconds. The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-write
OBJECT-TYPE    
  TimeInterval  

ieee8021BridgePortMrpLeaveTime 1.3.111.2.802.1.1.2.1.4.1.1.2
The MRP Leave time, in centiseconds. The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-write
OBJECT-TYPE    
  TimeInterval  

ieee8021BridgePortMrpLeaveAllTime 1.3.111.2.802.1.1.2.1.4.1.1.3
The MRP LeaveAll time, in centiseconds. The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-write
OBJECT-TYPE    
  TimeInterval  

ieee8021BridgePortMmrpTable 1.3.111.2.802.1.1.2.1.5.1
A table of MMRP control and status information about every bridge port. Augments the ieee8021BridgeBasePortTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ieee8021BridgePortMmrpEntry

ieee8021BridgePortMmrpEntry 1.3.111.2.802.1.1.2.1.5.1.1
MMRP control and status information for a bridge port.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ieee8021BridgePortMmrpEntry  

ieee8021BridgePortMmrpEnabledStatus 1.3.111.2.802.1.1.2.1.5.1.1.1
The administrative state of MMRP operation on this port. The value true(1) indicates that MMRP is enabled on this port in all VLANs as long as ieee8021BridgeMmrpEnabledStatus is also true(1). A value of false(2) indicates that MMRP is disabled on this port in all VLANs: any MMRP packets received will be silently discarded, and no MMRP registrations will be propagated from other ports. Setting this to a value of true(1) will be stored by the agent but will only take effect on the MMRP protocol operation if ieee8021BridgeMmrpEnabledStatus also indicates the value true(1). This object affects all MMRP Applicant and Registrar state machines on this port. A transition from false(2) to true(1) will cause a reset of all MMRP state machines on this port. The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

ieee8021BridgePortMmrpFailedRegistrations 1.3.111.2.802.1.1.2.1.5.1.1.2
The total number of failed MMRP registrations, for any reason, in all VLANs, on this port.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

ieee8021BridgePortMmrpLastPduOrigin 1.3.111.2.802.1.1.2.1.5.1.1.3
The Source MAC Address of the last MMRP message received on this port.
Status: current Access: read-only
OBJECT-TYPE    
  MacAddress  

ieee8021BridgePortRestrictedGroupRegistration 1.3.111.2.802.1.1.2.1.5.1.1.4
The state of Restricted Group Registration on this port. If the value of this control is true(1), then creation of a new dynamic entry is permitted only if there is a Static Filtering Entry for the VLAN concerned, in which the Registrar Administrative Control value is Normal Registration. The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

ieee8021BridgeILanIfTable 1.3.111.2.802.1.1.2.1.6.1
This table is a sparse augmentation of ifTable and controls the creation of the I-LAN Interface. An I-LAN Interface is used to create internal connections between bridge ports in a 802.1 device. An I-LAN Interfaces can be directly associated with a set of bridge ports. An I-LAN Interfaces can also be used as a stacking interface to relate other interfaces before association to bridge ports. For example, an I-LAN interface can be created to link traffic between a PIP and a CBP. In this case a CBP is created on the B-Component and the CBP's related IfEntry is stacked upon the IfEntry of the I-LAN. The PIP is stacked upon the I-LAN using the IfStackTable. Finally, a VIP is created on the I-Component and is associated with the PIP, thus completing the path from the I-Component's MAC relay to the CBP on the B-Component. Entries in this table MUST be persistent over power up restart/reboot.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ieee8021BridgeILanIfEntry

ieee8021BridgeILanIfEntry 1.3.111.2.802.1.1.2.1.6.1.1
Each entry consists of a Row Status to control creation.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ieee8021BridgeILanIfEntry  

ieee8021BridgeILanIfRowStatus 1.3.111.2.802.1.1.2.1.6.1.1.1
This object is used to create and delete entries in this table and the Interface table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

ieee8021BridgeDot1dPortTable 1.3.111.2.802.1.1.2.1.7.1
This table provides the capability to dynamically create and delete 802.1D bridge ports. Each entry in this table MUST have a corresponding entry in the ieee8021BridgeBasePortTable. Entries in this table MUST be persistent over power up restart/reboot.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ieee8021BridgeDot1dPortEntry

ieee8021BridgeDot1dPortEntry 1.3.111.2.802.1.1.2.1.7.1.1
Each entry consists of a Row Status to control creation.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ieee8021BridgeDot1dPortEntry  

ieee8021BridgeDot1dPortRowStatus 1.3.111.2.802.1.1.2.1.7.1.1.1
This object is used to create and delete entries in this table and the ieee8021BridgeBasePortTable.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

ieee8021BridgeCompliances 1.3.111.2.802.1.1.2.2.1
OBJECT IDENTIFIER    

ieee8021BridgeGroups 1.3.111.2.802.1.1.2.2.2
OBJECT IDENTIFIER    

ieee8021BridgeBaseBridgeGroup 1.3.111.2.802.1.1.2.2.2.1
Bridge level information for this device.
Status: current Access: read-create
OBJECT-GROUP    

ieee8021BridgeBasePortGroup 1.3.111.2.802.1.1.2.2.2.2
Information for each port on this device.
Status: current Access: read-create
OBJECT-GROUP    

ieee8021BridgeCapGroup 1.3.111.2.802.1.1.2.2.2.3
A collection of objects indicating the optional capabilities of the device.
Status: current Access: read-create
OBJECT-GROUP    

ieee8021BridgeDeviceMmrpGroup 1.3.111.2.802.1.1.2.2.2.4
A collection of objects providing device-level control for the Multicast Filtering extended bridge services.
Status: current Access: read-create
OBJECT-GROUP    

ieee8021BridgeTpPortGroup 1.3.111.2.802.1.1.2.2.2.6
Dynamic Filtering Database information for each port of the Bridge.
Status: current Access: read-create
OBJECT-GROUP    

ieee8021BridgeDevicePriorityGroup 1.3.111.2.802.1.1.2.2.2.7
A collection of objects providing device-level control for the Priority services.
Status: current Access: read-create
OBJECT-GROUP    

ieee8021BridgeDefaultPriorityGroup 1.3.111.2.802.1.1.2.2.2.8
A collection of objects defining the User Priority applicable to each port for media that do not support native User Priority.
Status: current Access: read-create
OBJECT-GROUP    

ieee8021BridgeRegenPriorityGroup 1.3.111.2.802.1.1.2.2.2.9
A collection of objects defining the User Priorities applicable to each port for media that support native User Priority.
Status: current Access: read-create
OBJECT-GROUP    

ieee8021BridgePriorityGroup 1.3.111.2.802.1.1.2.2.2.10
A collection of objects defining the traffic classes within a bridge for each evaluated User Priority.
Status: current Access: read-create
OBJECT-GROUP    

ieee8021BridgeAccessPriorityGroup 1.3.111.2.802.1.1.2.2.2.11
A collection of objects defining the media-dependent outbound access level for each priority.
Status: current Access: read-create
OBJECT-GROUP    

ieee8021BridgePortMrpGroup 1.3.111.2.802.1.1.2.2.2.12
A collection of objects providing port level control and status information for MRP operation.
Status: current Access: read-create
OBJECT-GROUP    

ieee8021BridgePortMmrpGroup 1.3.111.2.802.1.1.2.2.2.13
A collection of objects providing port level control and status information for MMRP operation.
Status: deprecated Access: read-create
OBJECT-GROUP    

ieee8021BridgePortDecodingGroup 1.3.111.2.802.1.1.2.2.2.14
A collection of objects providing statistics counters for decoding priority and drop eligibility for bridge ports.
Status: current Access: read-create
OBJECT-GROUP    

ieee8021BridgePortEncodingGroup 1.3.111.2.802.1.1.2.2.2.15
A collection of objects providing statistics counters for encoding priority and drop eligibility for bridge ports.
Status: current Access: read-create
OBJECT-GROUP    

ieee8021BridgeServiceAccessPriorityGroup 1.3.111.2.802.1.1.2.2.2.16
A collection of objects providing statistics counters for service access priority.
Status: current Access: read-create
OBJECT-GROUP    

ieee8021BridgeInternalLANGroup 1.3.111.2.802.1.1.2.2.2.17
A collection of objects providing control of internal LAN configuration.
Status: current Access: read-create
OBJECT-GROUP    

ieee8021BridgeCreatableBaseBridgeGroup 1.3.111.2.802.1.1.2.2.2.18
Controls the managment system directed creation of Bridge Components.
Status: current Access: read-create
OBJECT-GROUP    

ieee8021BridgeDot1dDynamicPortCreationGroup 1.3.111.2.802.1.1.2.2.2.19
A collection of objects providing dynamic creation and deletion of 802.1D bridge ports.
Status: current Access: read-create
OBJECT-GROUP    

ieee8021BridgeBaseIfToPortGroup 1.3.111.2.802.1.1.2.2.2.20
A collection of objects providing a map between interface index and component ID and bridge ports.
Status: current Access: read-create
OBJECT-GROUP    

ieee8021BridgePhyPortGroup 1.3.111.2.802.1.1.2.2.2.21
The collection of objects used to represent a ISS port management objects.
Status: current Access: read-create
OBJECT-GROUP    

ieee8021BridgeCompliance1 1.3.111.2.802.1.1.2.2.1.3
The compliance statement for devices supporting bridging services as defined in 802.1D-2004. Such devices support path cost values of 32-bits, and bridge and port priority values are more restricted than in 802.1D-1995. Full support for the 802.1D management objects requires implementation of the objects listed in the systemGroup from the SNMPv2-MIB [RFC3418], as well as the objects listed in the ifGeneralInformationGroup from the IF-MIB [RFC2863].
Status: current Access: read-create
MODULE-COMPLIANCE    

ieee8021BridgeCompliance 1.3.111.2.802.1.1.2.2.1.1
The compliance statement for devices supporting bridging services as defined in 802.1D-2004. Such devices support path cost values of 32-bits, and bridge and port priority values are more restricted than in 802.1D-1995. Full support for the 802.1D management objects requires implementation of the objects listed in the systemGroup from the SNMPv2-MIB [RFC3418], as well as the objects listed in the ifGeneralInformationGroup from the IF-MIB [RFC2863].
Status: current Access: read-create
MODULE-COMPLIANCE    

ieee8021BridgePriorityAndMulticastFilteringCompliance 1.3.111.2.802.1.1.2.2.1.2
The compliance statement for device support of Priority and Multicast Filtering extended bridging services.
Status: deprecated Access: read-only
MODULE-COMPLIANCE