HUAWEI-BTEST-MIB

File: HUAWEI-BTEST-MIB.mib (84785 bytes)

Imported modules

HUAWEI-MIB HUAWEI-TC-MIB IF-MIB
HUAWEI-DEVICE-MIB SNMPv2-SMI SNMPv2-TC
HUAWEI-COMMTEST-MIB

Imported symbols

huaweiUtility HWPortType ifIndex
hwFrameIndex hwSlotIndex Integer32
Unsigned32 OBJECT-TYPE MODULE-IDENTITY
NOTIFICATION-TYPE TEXTUAL-CONVENTION RowStatus
hwTestGroupNo

Defined Types

HWBTSSxDslLineOverLap  
Set overlap mode of xDSL with PSTN line. Options: 1. overLap(1) - xDSL overlap with POTS line 2. direct(2) - There is no pots line, no splitter, no phone 3. unknown(3) - The mode is unknown
TEXTUAL-CONVENTION    
  INTEGER overLap(1), direct(2), unknown(3)  

CqtQualitativeResultString  
This string to contain qualitative result.
TEXTUAL-CONVENTION    
  OCTET STRING Size(0..255)  

HwBTSSxDslLineCfgEntry  
SEQUENCE    
  hwBTSSxDslLineOverlapType HWBTSSxDslLineOverLap

HwBTSSCoTestEntry  
SEQUENCE    
  hwBTSSCoOperType INTEGER
  hwBTSSCoTestResult INTEGER
  hwBTSSCoTestBusyFlag INTEGER

HwBTSSAuxPortCfgEntry  
SEQUENCE    
  hwBTSSAuxPortType INTEGER
  hwBTSSAuxPortIfIndex Integer32
  hwBTSSAuxPortRowStatus RowStatus

HwBTSSTestedPortOperEntry  
SEQUENCE    
  hwBTSSTestedPortOperType INTEGER
  hwBTSSTestedPortOperMode INTEGER
  hwBTSSTestedPortOperResult INTEGER
  hwBTSSTestedPortTestBusyFlag INTEGER
  hwBTSSTestedPortTestPOTSFlag INTEGER

HwBTSSCqtTransTestEntry  
SEQUENCE    
  hwBTSSCqtTransTestOperType INTEGER
  hwBTSSCqtTransTestCRCMode INTEGER
  hwBTSSCqtTransTestOperResult INTEGER
  hwBTSSCqtTransTestTxCmd OCTET STRING
  hwBTSSCqtTransTestResultNo Integer32
  hwBTSSCqtTransTestResultLastFlag INTEGER
  hwBTSSCqtTransTestResult OCTET STRING

HwBTSSMultiFrameMiscOperEntry  
SEQUENCE    
  hwBTSSMultiFrameMiscCleanTest INTEGER
  hwBTSSMultiFrameMiscTestedFrame Integer32
  hwBTSSMultiFrameMiscTestedPortType HWPortType
  hwBTSSMultiFrameMiscTestedLineType HWBTSSxDslLineOverLap

HWBTSSAdslSeltTestEntry  
SEQUENCE    
  hwBTSSAdslSeltTestOperType INTEGER
  hwBTSSAdslSeltTestOperResult INTEGER
  hwBTSSAdslSeltTestResultNo Integer32
  hwBTSSAdslSeltTestResultLastFlag INTEGER
  hwBTSSAdslSeltTestResult OCTET STRING
  hwBTSSAdslSeltTestParamLoopLength Integer32
  hwBTSSAdslSeltTestParamLoopTermin INTEGER
  hwBTSSAdslSeltTestParamLoopGauge INTEGER
  hwBTSSAdslSeltTestParamUpShnCap Integer32
  hwBTSSAdslSeltTestParamDwnShnCap Integer32
  hwBTSSAdslSeltTestParamInbandNoise OCTET STRING
  hwBTSSAdslSeltTestParamTerminResp OCTET STRING
  hwBTSSAdslSeltTestParamUpMgnAtRate OCTET STRING
  hwBTSSAdslSeltTestParamDwnMgnAtRate OCTET STRING
  hwBTSSAdslSeltTestParamUpRateAtMgn OCTET STRING
  hwBTSSAdslSeltTestParamDwnRateAtMgn OCTET STRING
  hwBTSSAdslSeltTestParamLoopAttenAtFreq OCTET STRING
  hwBTSSAdslSeltTestParamUnCalibLineScale Unsigned32
  hwBTSSAdslSeltTestParamUnCalibEchoRespReal OCTET STRING
  hwBTSSAdslSeltTestParamUnCalibEchoRespImg OCTET STRING
  hwBTSSAdslSeltTestParamCalibLineScale Unsigned32
  hwBTSSAdslSeltTestParamCalibEchoRespReal OCTET STRING
  hwBTSSAdslSeltTestParamCalibEchoRespImg OCTET STRING
  hwBTSSAdslSeltTestParamVarUerC OCTET STRING
  hwBTSSAdslSeltTestParamUerMmdC Unsigned32
  hwBTSSAdslSeltTestParamQlnMmdC Unsigned32
  hwBTSSAdslSeltTestParamUmeC INTEGER
  hwBTSSAdslSeltTestParamQmeC INTEGER
  hwBTSSAdslSeltTestParamUerStatus INTEGER
  hwBTSSAdslSeltTestParamQlnStatus INTEGER
  hwBTSSAdslSeltTestParamCalcEnable INTEGER
  hwBTSSAdslSeltTestParamAttnAt180KHZ Integer32
  hwBTSSAdslSeltTestParamAttnAt300KHZ Integer32
  hwBTSSAdslSeltTestParamQSPsdValue OCTET STRING

HWBTSSAdslDeltTestEntry  
SEQUENCE    
  hwBTSSAdslDeltTestOperType INTEGER
  hwBTSSAdslDeltTestOperResult INTEGER
  hwBTSSAdslDeltTestResultNo Integer32
  hwBTSSAdslDeltTestResultLastFlag INTEGER
  hwBTSSAdslDeltTestResult OCTET STRING

HwBTSSLoopLineToneOprEntry  
SEQUENCE    
  hwBTSSLoopLineToneOprType INTEGER
  hwBTSSLoopLineToneIntensity INTEGER
  hwBTSSLoopLineToneBusyFlag INTEGER
  hwBTSSLoopLineToneResult INTEGER

HwBTSSSeltAuxPortCfgEntry  
SEQUENCE    
  hwBTSSSeltAuxedPortIfIndex Integer32
  hwBTSSSeltAuxPortIfIndex Integer32
  hwBTSSSeltAuxPortRowStatus RowStatus

HwBTSSAdslSeltLevelEntry  
SEQUENCE    
  hwBTSSAdslSeltLevel Integer32

HWBTSSAdslSeltCalibrationtEntry  
SEQUENCE    
  hwBTSSAdslSeltCalibrationInvVendorId OCTET STRING
  hwBTSSAdslSeltCalibrationDataSegment1 OCTET STRING
  hwBTSSAdslSeltCalibrationDataSegment2 OCTET STRING

Defined Values

hwBTest 1.3.6.1.4.1.2011.6.21.3
This MIB is used for defining Huawei's BTEST MIB objects,which is used for Broad test.
MODULE-IDENTITY    

hwTest 1.3.6.1.4.1.2011.6.21
OBJECT IDENTIFIER    

hwBTestMib 1.3.6.1.4.1.2011.6.21.3.1
OBJECT IDENTIFIER    

hwBTestMIBObjects 1.3.6.1.4.1.2011.6.21.3.1.1
OBJECT IDENTIFIER    

hwBTSSxDslLineCfgTable 1.3.6.1.4.1.2011.6.21.3.1.1.1
The hwBTSSxDslLineCfgTable table describes xDSL line configuration. This table is used for bandwidth test. The index of this table is ifIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwBTSSxDslLineCfgEntry

hwBTSSxDslLineCfgEntry 1.3.6.1.4.1.2011.6.21.3.1.1.1.1
The hwBTSSxDslLineCfgTable table describes xDSL line configuration. This table is used for bandwidth test. The index of this entry is ifIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwBTSSxDslLineCfgEntry  

hwBTSSxDslLineOverlapType 1.3.6.1.4.1.2011.6.21.3.1.1.1.1.1
Overlap mode of xDSL with PSTN line. Options: 1. overLap(1) - xDSL overlap with POTS line 2. direct(2) - There is no pots line, no splitter, no phone 3. unknown(3) - The mode is unknown Default: unknown(3)
Status: current Access: read-write
OBJECT-TYPE    
  HWBTSSxDslLineOverLap  

hwBTSSCoTestTable 1.3.6.1.4.1.2011.6.21.3.1.1.2
xDSL central office emulational measurement table.The table is used for xDSL central emulational measurement. The index of this table is ifIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwBTSSCoTestEntry

hwBTSSCoTestEntry 1.3.6.1.4.1.2011.6.21.3.1.1.2.1
xDSL central office emulational measurement table.The table is used for xDSL central emulational measurement. The index of this entry is ifIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwBTSSCoTestEntry  

hwBTSSCoOperType 1.3.6.1.4.1.2011.6.21.3.1.1.2.1.1
CO emulational operation type. Options: 1. stop(1) - Stop CO emulational 2. start(2) - Start CO emulational
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER stop(1), start(2)  

hwBTSSCoTestResult 1.3.6.1.4.1.2011.6.21.3.1.1.2.1.2
CO emulational test result. Options: 1. normal(1) - The test of CO emulational is successful 2. testfail(2) - Fail in test of CO emulational
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER normal(1), testfail(2)  

hwBTSSCoTestBusyFlag 1.3.6.1.4.1.2011.6.21.3.1.1.2.1.3
CO force test flag Options: 1. busyNoTest(1) - No test on busy 2. busyTest(2) - Test on busy 3. busystrenTest(3) - Forced test on busy
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER busyNoTest(1), busyTest(2), busystrenTest(3)  

hwBTSSAuxPortCfgTable 1.3.6.1.4.1.2011.6.21.3.1.1.17
Configuration table of the broadband test auxiliary port This table is used to configure a certain type of emulation port required in the CO emulation test. The indexes of this table are hwTestGroupNo and hwBTSSAuxPortType.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwBTSSAuxPortCfgEntry

hwBTSSAuxPortCfgEntry 1.3.6.1.4.1.2011.6.21.3.1.1.17.1
Configuration table of the broadband test auxiliary port This table is used to configure a certain type of emulation port required in the CO emulation test. The indexes of this entry are hwTestGroupNo and hwBTSSAuxPortType.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwBTSSAuxPortCfgEntry  

hwBTSSAuxPortType 1.3.6.1.4.1.2011.6.21.3.1.1.17.1.1
Assistance port type of BTSS. Options: 1. adsl(1) - Assistance port type of BTSS is adsl 2. vdsl(2) - Assistance port type of BTSS is vdsl 3. gshdsl(3) - Assistance port type of BTSS is gshdsl
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER adsl(1), vdsl(2), gshdsl(3)  

hwBTSSAuxPortIfIndex 1.3.6.1.4.1.2011.6.21.3.1.1.17.1.2
Assistance port ifIndex of BTSS.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

hwBTSSAuxPortRowStatus 1.3.6.1.4.1.2011.6.21.3.1.1.17.1.3
Row status(add(4),delete(6)).
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

hwBTSSTestedPortOperTable 1.3.6.1.4.1.2011.6.21.3.1.1.18
This table describes operation for tested port. The index of this table is ifIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwBTSSTestedPortOperEntry

hwBTSSTestedPortOperEntry 1.3.6.1.4.1.2011.6.21.3.1.1.18.1
This table describes operation for tested port. The index of this entry is ifIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwBTSSTestedPortOperEntry  

hwBTSSTestedPortOperType 1.3.6.1.4.1.2011.6.21.3.1.1.18.1.1
Operation type of BTSS tested port. Options: 1. capture(1) - Capture 2. release(2) - Release 3. startmonitor(3) - Start monitor 4. stopmonitor(4) - Stop monitor 5. resumeport(5) - Resume port 6. invalid(-1) - Invalid value
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER capture(1), release(2), startmonitor(3), stopmonitor(4), resumeport(5), invalid(-1)  

hwBTSSTestedPortOperMode 1.3.6.1.4.1.2011.6.21.3.1.1.18.1.2
Operation mode of BTSS tested port. Options: 1. inline(1) - BTSS tested port in test 2. outline(2) - BTSS tested port out test 3. monitor(3) - Monitoring BTSS tested port 4. both(4) - Capture for circuit and loop-line test 5. meltNoCutxDSL(5) - Capture for melt chip test with co and cpe connecting 6. meltForceCutxDSL(6) - Capture for melt chip test with co and cpe disconnecting 7. testLineLoopback(7) - Capture for test line loopback 8. internalResistorLoopback(8) - Capture for internal resistor loopback 9. passthroughmode(9) - No capture Default: passthroughmode(9)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER inline(1), outline(2), monitor(3), both(4), meltNoCutxDSL(5), meltForceCutxDSL(6), testLineLoopback(7), internalResistorLoopback(8), passthroughmode(9)  

hwBTSSTestedPortOperResult 1.3.6.1.4.1.2011.6.21.3.1.1.18.1.3
Test result of BTSS tested port. Options: 1. normal(1) - The test of BTSS tested port is successful 2. fail(2) - Fail in test of BTSS tested port 3. timeout(4) - The test of BTSS tested port is timeout
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER normal(1), fail(2), timeout(4)  

hwBTSSTestedPortTestBusyFlag 1.3.6.1.4.1.2011.6.21.3.1.1.18.1.4
Tested port force test. Options: 1. busyNoTest(1) - No test on busy 2. busyTest(2) - Test on busy 3. busystrenTest(3) - Forced test on busy
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER busyNoTest(1), busyTest(2), busystrenTest(3)  

hwBTSSTestedPortTestPOTSFlag 1.3.6.1.4.1.2011.6.21.3.1.1.18.1.5
Tested port POTS service flag Options: 1. noCutPOTS(1) - No cut off POTS 2. busyNoTest(2) - No test on POTS busy (Cut off POTS) 3. busyTest(3) - Test on POTS busy (Cut off POTS) 4. busystrenTest(4) - Forced test on POTS busy (Cut off POTS)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noCutPOTS(1), busyNoTest(2), busyTest(3), busystrenTest(4)  

hwBTSSCqtTransTestTable 1.3.6.1.4.1.2011.6.21.3.1.1.19
This table describes CQT test by transparent command. The index of this table is ifIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwBTSSCqtTransTestEntry

hwBTSSCqtTransTestEntry 1.3.6.1.4.1.2011.6.21.3.1.1.19.1
This table describes CQT test by transparent command. The index of this entry is ifIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwBTSSCqtTransTestEntry  

hwBTSSCqtTransTestOperType 1.3.6.1.4.1.2011.6.21.3.1.1.19.1.1
CQT transparent Operation type Options: 1. stop(1) - Stop CQT transparent test 2. start(2) - Start CQT transparent test
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER stop(1), start(2)  

hwBTSSCqtTransTestCRCMode 1.3.6.1.4.1.2011.6.21.3.1.1.19.1.2
CRC Operation type of CQT transparent. Options: 1. disable(1) - Disable CQT transparent 2. enable(2) - Enable CQT transparent Default: disable(1)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

hwBTSSCqtTransTestOperResult 1.3.6.1.4.1.2011.6.21.3.1.1.19.1.3
CQT transparent Operation result. Options: 1. normal(1) - The CQT transparent test is successful 2. fail(2) - The CQT transparent test fails 3. abort(3) - The CQT transparent test aborts 4. powerfeed(4) - The CQT transparent test power feeds
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER normal(1), fail(2), abort(3), powerfeed(4)  

hwBTSSCqtTransTestTxCmd 1.3.6.1.4.1.2011.6.21.3.1.1.19.1.4
Sending command string in TL1 format.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..251)  

hwBTSSCqtTransTestResultNo 1.3.6.1.4.1.2011.6.21.3.1.1.19.1.5
Test result No. Range: 1-255
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32 1..255  

hwBTSSCqtTransTestResultLastFlag 1.3.6.1.4.1.2011.6.21.3.1.1.19.1.6
Last package flag for test result. Options: 1. false(0) - This is not the last package 2. true(1) - The last package
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER false(0), true(1)  

hwBTSSCqtTransTestResult 1.3.6.1.4.1.2011.6.21.3.1.1.19.1.7
CQT transparent Test result.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  OCTET STRING Size(0..231)  

hwBTSSMultiFrameMiscOperTable 1.3.6.1.4.1.2011.6.21.3.1.1.20
This table describes test relatived operation for multi-frame. The index of this table is ifIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwBTSSMultiFrameMiscOperEntry

hwBTSSMultiFrameMiscOperEntry 1.3.6.1.4.1.2011.6.21.3.1.1.20.1
This table describes test relatived operation for multi-frame. The index of this entry is ifIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwBTSSMultiFrameMiscOperEntry  

hwBTSSMultiFrameMiscCleanTest 1.3.6.1.4.1.2011.6.21.3.1.1.20.1.1
Clean current test on specified frame. Options: 1. start(1) - Start clean current test
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER start(1)  

hwBTSSMultiFrameMiscTestedFrame 1.3.6.1.4.1.2011.6.21.3.1.1.20.1.2
Tested frame of BTSS multi-frame. Default: 0
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

hwBTSSMultiFrameMiscTestedPortType 1.3.6.1.4.1.2011.6.21.3.1.1.20.1.3
Tested port type of BTSS multi-frame.
Status: current Access: read-write
OBJECT-TYPE    
  HWPortType  

hwBTSSMultiFrameMiscTestedLineType 1.3.6.1.4.1.2011.6.21.3.1.1.20.1.4
Tested line type of BTSS multi-frame.
Status: current Access: read-write
OBJECT-TYPE    
  HWBTSSxDslLineOverLap  

hwBTSSAdslSeltTestTable 1.3.6.1.4.1.2011.6.21.3.1.1.21
This table describes selt test for adsl2+. The index of this table is ifIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HWBTSSAdslSeltTestEntry

hwBTSSAdslSeltTestEntry 1.3.6.1.4.1.2011.6.21.3.1.1.21.1
This table describes selt test for adsl2+. The index of this entry is ifIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  HWBTSSAdslSeltTestEntry  

hwBTSSAdslSeltTestOperType 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.1
Selt test operation type. Options: 1. stop(1) - Stop selt test of BTSS 2. start(2) - Start selt test of BTSS 3. invalid(-1) - No operation
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER stop(1), start(2), invalid(-1)  

hwBTSSAdslSeltTestOperResult 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.2
Selt test operation result. Options: 1. normal(1) - Selt test of BTSS is successful 2. fail(2) - Fail in selt test of BTSS 3. abort(3) - Selt test of BTSS aborts
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER normal(1), fail(2), abort(3)  

hwBTSSAdslSeltTestResultNo 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.3
Selt test result serial number. Range: 1-255
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32 1..255  

hwBTSSAdslSeltTestResultLastFlag 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.4
Last package flag of test. Options: 1. false(0) - This is not the last package 2. true(1) - The last package
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER false(0), true(1)  

hwBTSSAdslSeltTestResult 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.5
Selt test result data.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  OCTET STRING Size(0..1500)  

hwBTSSAdslSeltTestParamLoopLength 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.6
Selt test parameter Loop Length. The invalid value is -1. If no SELT is performed, no SELT data is generated because the SELT is incomplete, or no SELT data can be obtained from the port because the SELT data is aged and cleared, the invalid value will be returned.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwBTSSAdslSeltTestParamLoopTermin 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.7
Selt test parameter Loop Termination state. Options: 1. open(0) - Indicates that the line terminal is started 2. short(1) - Indicates that the line terminal is short-circuited 3. unknow(2) - Indicates the unknown state 4. terminated(3) - Indicates that the line terminal is stopped 5. invalid(-1) - Indicates the invalid state
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER open(0), short(1), unknow(2), terminated(3), invalid(-1)  

hwBTSSAdslSeltTestParamLoopGauge 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.8
Selt test parameter Loop Gauge. Options: 1. greater26awg(1) - Indicates that the line gauge is greater than 26 2. equal26awg(2) - Indicates that the line gauge is 26 3. equal24awg(3) - Indicates that the line gauge is 24 4. less24awg(4) - Indicates that the line gauge is smaller than 24 5. unknowawg(5) - Indicates an unknown line gauge. 6. invalid(-1) - Indicates an invalid value.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER greater26awg(1), equal26awg(2), equal24awg(3), less24awg(4), unknowawg(5), invalid(-1)  

hwBTSSAdslSeltTestParamUpShnCap 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.9
Selt test parameter Upstream Shannon Capacity. The invalid value is -1. If no SELT is performed, no SELT data is generated because the SELT is incomplete, or no SELT data can be obtained from the port because the SELT data is aged and cleared, the invalid value will be returned.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwBTSSAdslSeltTestParamDwnShnCap 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.10
Selt test parameter Downstream Shannon Capacity.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwBTSSAdslSeltTestParamInbandNoise 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.11
Selt test parameter Inband Noise 512 values that indicate inband noise in dBm/Hz, covering ADSL, ADSL2, and ADSL2+ bands, from 0 to 2.2 MHz.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..1500)  

hwBTSSAdslSeltTestParamTerminResp 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.12
Selt test parameter Termination Response 180 values that indicate termination response magnitude from 0 to 18 kft.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..1500)  

hwBTSSAdslSeltTestParamUpMgnAtRate 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.13
Selt test parameter Upstream Ratevs. Margin. This value is a measure of the quality of your upstream data signal relative to the noise on the line. Hundreds of values that indicate SNR margin in DB/Hz at a particular bit rate are provided, at a certain increments, up to 30 Mbps. This information may be plotted with the bit rate on the X-axis and the SNR margin on the Y-axis.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..1500)  

hwBTSSAdslSeltTestParamDwnMgnAtRate 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.14
Selt test parameter Downstream Rate vs. Margin. This value is a measure of the quality of your downstream data signal relative to the noise on the line. Hundreds of values that indicate SNR margin in DB/Hz at a particular bit rate are provided, at a certain increments, up to 30 Mbps. This information may be plotted with the bit rate on the X-axis and the SNR margin on the Y-axis.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..1500)  

hwBTSSAdslSeltTestParamUpRateAtMgn 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.15
Selt test parameter Upstream Margin vs. Rate.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..1500)  

hwBTSSAdslSeltTestParamDwnRateAtMgn 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.16
Selt test parameter Downstream Margin vs. Rate.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..1500)  

hwBTSSAdslSeltTestParamLoopAttenAtFreq 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.17
Selt test parameter loop attenuation versus frequency. Every four bytes constitute the result of a tone. This information may be plotted with the bit frequency on the X-axis and the loop attenuation on the Y-axis.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..2048)  

hwBTSSAdslSeltTestParamUnCalibLineScale 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.18
The uncalibrated echo response, UER(i* UER_G*Df), shall be represented in linear format by a scale factor and a normalized complex number a(i)+j*b(i), where i is a frequency index i ranging from 0 to NSC-1, the subcarrier spacing, Df = 4.3125 kHz, and (NSC-1) * UER_G * Df is the highest frequency supported by the SELT-PMD functionality. The UER granularity parameter, UER_G, has two valid values: 1 and 2, indicating whether the measurements were performed using a tone spacing of 4.3125 kHz or of 8.625 kHz. If the uncalibrated echo response is being reported over a frequency range of 17.664 MHz or lower, UER_G shall be set to 1. If the uncalibrated echo response is being reported over a frequency range that is greater than 17.664 MHz, UER_G shall be set to 2. The scale factor shall be coded as a 32-bit unsigned integer. Both a(i) and b(i) shall be coded as 32-bit 2's complement signed integers. The value of UER(i* UER_G*Df) shall be defined as: UER(i* UER_G*Df) = (scale/2^31)*(a(i)+j*b(i))/2^31. In order to maximize precision, the scale factor shall be chosen such that max(|a(i)|, |b(i)|) over all i is equal to 2^31-1. NOTE - This data format supports an UER(f) granularity of 2^-31 and an UER(f) dynamic range of approximately +6 dB to -186 dB, however it does not imply any future accuracy requirements. An UER(i*UER_G* Df) value indicated as a(i) = b(i) = -2^31 is a special value. It indicates that no measurement could be done for this subcarrier either because it is not supported by the SELT-PMD function, or that the value is out of range to be represented.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

hwBTSSAdslSeltTestParamUnCalibEchoRespReal 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.19
The uncalibrated echo response, UER(i* UER_G*Df), shall be represented in linear format by a scale factor and a normalized complex number a(i)+j*b(i), where i is a frequency index i ranging from 0 to NSC-1, the subcarrier spacing, Df = 4.3125 kHz, and (NSC-1) * UER_G * Df is the highest frequency supported by the SELT-PMD functionality. The UER granularity parameter, UER_G, has two valid values: 1 and 2, indicating whether the measurements were performed using a tone spacing of 4.3125 kHz or of 8.625 kHz. If the uncalibrated echo response is being reported over a frequency range of 17.664 MHz or lower, UER_G shall be set to 1. If the uncalibrated echo response is being reported over a frequency range that is greater than 17.664 MHz, UER_G shall be set to 2. The scale factor shall be coded as a 32-bit unsigned integer. Both a(i) and b(i) shall be coded as 32-bit 2's complement signed integers. The value of UER(i* UER_G*Df) shall be defined as: UER(i* UER_G*Df) = (scale/2^31)*(a(i)+j*b(i))/2^31. In order to maximize precision, the scale factor shall be chosen such that max(|a(i)|, |b(i)|) over all i is equal to 2^31-1. NOTE - This data format supports an UER(f) granularity of 2^-31 and an UER(f) dynamic range of approximately +6 dB to -186 dB, however it does not imply any future accuracy requirements. An UER(i*UER_G* Df) value indicated as a(i) = b(i) = -2^31 is a special value. It indicates that no measurement could be done for this subcarrier either because it is not supported by the SELT-PMD function, or that the value is out of range to be represented.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..2048)  

hwBTSSAdslSeltTestParamUnCalibEchoRespImg 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.20
The uncalibrated echo response, UER(i* UER_G*Df), shall be represented in linear format by a scale factor and a normalized complex number a(i)+j*b(i), where i is a frequency index i ranging from 0 to NSC-1, the subcarrier spacing, Df = 4.3125 kHz, and (NSC-1) * UER_G * Df is the highest frequency supported by the SELT-PMD functionality. The UER granularity parameter, UER_G, has two valid values: 1 and 2, indicating whether the measurements were performed using a tone spacing of 4.3125 kHz or of 8.625 kHz. If the uncalibrated echo response is being reported over a frequency range of 17.664 MHz or lower, UER_G shall be set to 1. If the uncalibrated echo response is being reported over a frequency range that is greater than 17.664 MHz, UER_G shall be set to 2. The scale factor shall be coded as a 32-bit unsigned integer. Both a(i) and b(i) shall be coded as 32-bit 2's complement signed integers. The value of UER(i* UER_G*Df) shall be defined as: UER(i* UER_G*Df) = (scale/2^31)*(a(i)+j*b(i))/2^31. In order to maximize precision, the scale factor shall be chosen such that max(|a(i)|, |b(i)|) over all i is equal to 2^31-1. NOTE - This data format supports an UER(f) granularity of 2^-31 and an UER(f) dynamic range of approximately +6 dB to -186 dB, however it does not imply any future accuracy requirements. An UER(i*UER_G* Df) value indicated as a(i) = b(i) = -2^31 is a special value. It indicates that no measurement could be done for this subcarrier either because it is not supported by the SELT-PMD function, or that the value is out of range to be represented.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..2048)  

hwBTSSAdslSeltTestParamCalibLineScale 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.21
The scale factor of calibrated echo response shall be coded as a 16 bit unsigned integer.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

hwBTSSAdslSeltTestParamCalibEchoRespReal 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.22
The calibrated echo response UER(i* f), shall be represented in linear format by a scale factor and a normalized complex number a(i)+j*b(i), where i is the subcarrier index i ranging from 0 to NSC-1 and Df = 4.3125kHz and (NSC-1) * Df is the highest frequency supported by the SELT-PMD functionality. The scale factor shall be coded as a 16 bit unsigned integer. Both a(i) and b(i) shall be coded as a 16 bit 2's complement signed integer. The value of UER(i* f) shall be defined as UER(i* f) = (scale/215)*(a(i)+j*b(i))/215. In order to maximize precision, the scale factor shall be chosen such that max(|a(i)|, |b(i)|) over all i is equal to 215-1. This data format supports an UER(f) granularity of 2-15 and an UER(f) dynamic range of approximately +6 dB to -90 dB. An UER(i*Df) value indicated as a(i) = b(i) = -215 is a special value. It indicates that no measurement could be done for this subcarrier because it is out of the PSD mask passband or that the value is out of range to be represented.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..2048)  

hwBTSSAdslSeltTestParamCalibEchoRespImg 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.23
The calibrated echo response UER(i* f), shall be represented in linear format by a scale factor and a normalized complex number a(i)+j*b(i), where i is the subcarrier index i ranging from 0 to NSC-1 and Df = 4.3125kHz and (NSC-1) * Df is the highest frequency supported by the SELT-PMD functionality. The scale factor shall be coded as a 16 bit unsigned integer. Both a(i) and b(i) shall be coded as a 16 bit 2's complement signed integer. The value of UER(i* f) shall be defined as UER(i* f) = (scale/215)*(a(i)+j*b(i))/215. In order to maximize precision, the scale factor shall be chosen such that max(|a(i)|, |b(i)|) over all i is equal to 215-1. This data format supports an UER(f) granularity of 2-15 and an UER(f) dynamic range of approximately +6 dB to -90 dB. An UER(i*Df) value indicated as a(i) = b(i) = -215 is a special value. It indicates that no measurement could be done for this subcarrier because it is out of the PSD mask passband or that the value is out of range to be represented.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..2048)  

hwBTSSAdslSeltTestParamVarUerC 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.24
The relative variance of the uncalibrated echo response REL_VAR_UER(i* UER_G *Df) shall be represented as an 8-bit unsigned integer v(i), where i is the subcarrier index i = 0 to NSC-1. The value of REL_VAR_UER(i* UER_G *Df) shall be defined as REL_VAR_UER(i* UER_G *Df) = 3 - v(i)/2 dB. The number v(i) is an 8-bit unsigned integer in the range 0 to 254. This data format supports a REL_VAR_UER(i) over a range from -124 dB to +3 dB for each carrier with a granularity from 0.5 dB. Out of range values shall be clamped to the closest range bound. The special value v(i) = 255 indicates that no measurement is available for that carrier. Unit: 0.5dB
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..2048)  

hwBTSSAdslSeltTestParamUerMmdC 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.25
This parameter is the maximum allowed time for SELT uncalibrated echo response measurement, between the time of the start command written by the SELT-PMD-ME, and the time the result is available for read operation by SELT-PMD-ME. It is configurable between 5 seconds and 240 seconds, in steps of 1 second. The invalid value is 255. If data on the port cannot be queried, the invalid value will be returned. Unit: 1 second
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

hwBTSSAdslSeltTestParamQlnMmdC 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.26
This parameter is the maximum allowed time for SELT quiet line noise measurement, between the time of the start command written by the SELT-PMD-ME, and the time the result is available for read operation by SELT-PMD-ME. It is configurable between 1 second and 240 seconds, in steps of 1 second. The invalid value is 255. If data on the port cannot be queried, the invalid value will be returned. Unit: 1 second
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

hwBTSSAdslSeltTestParamUmeC 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.27
This parameter is a binary variable. Options: 1.enable(1) - Enable UER capture switch 2.disable(2) - Disable UER capture switch 3.invalid(-1) - Invalid value
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2), invalid(-1)  

hwBTSSAdslSeltTestParamQmeC 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.28
This parameter is a binary variable. Options: 1.enable(1) - Enable QLN capture switch 2.disable(2) - Disable QLN capture switch 3.invalid(-1) - Invalid value
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2), invalid(-1)  

hwBTSSAdslSeltTestParamUerStatus 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.29
UerStatus. Options: 1.off(1) - The status is off. 2.running(2) - The status is running. 3.completed(3) - The status is completed. 4.failed(4) - The status is failed.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(1), running(2), completed(3), failed(4)  

hwBTSSAdslSeltTestParamQlnStatus 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.30
QlnStatus. Options: 1.off(1) - The status is off. 2.running(2) - The status is running. 3.completed(3) - The status is completed. 4.failed(4) - The status is failed.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(1), running(2), completed(3), failed(4)  

hwBTSSAdslSeltTestParamCalcEnable 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.31
The status of calculation switch. Options: 1. enable(1) - Enable calculation switch 2. disable(2) - Disable calculation switch 3. invalid(-1) - Invalid value Default: enable(1)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2), invalid(-1)  

hwBTSSAdslSeltTestParamAttnAt180KHZ 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.65535
Selt test parameter attenuation at 180KHZ. It ranges from -1100 to 0 units of 0.1dB(physical values are -110 to 0 dB). The invalid value is -1. If no SELT is performed, no SELT data is generated because the SELT is incomplete, or no SELT data can be obtained from the port because the SELT data is aged and cleared, the invalid value will be returned. Unit: 0.1dB
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwBTSSAdslSeltTestParamAttnAt300KHZ 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.65536
Selt test parameter attenuation at 300KHZ. It ranges from -1100 to 0 units of 0.1dB(physical values are -110 to 0 dB). The invalid value is -1. If no SELT is performed, no SELT data is generated because the SELT is incomplete, or no SELT data can be obtained from the port because the SELT data is aged and cleared, the invalid value will be returned. Unit: 0.1dB
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwBTSSAdslSeltTestParamQSPsdValue 1.3.6.1.4.1.2011.6.21.3.1.1.21.1.65537
The SELT quiet line noise provides the quiet line noise PSD as measured by the SELT-PMD function (see clause A.1.1.2) for each sub-carrier frequency i * SELTQLN_G * Df where i ranges from 0 to NSC-1, Df = 4.3125 kHz, and (NSC-1) * SELTQLN_G * Df is the highest frequency supported by the SELT-PMD functionality. SELTQLN_G has two valid values: 1 and 2, indicating whether the measurements were performed using a tone spacing of 4.3125 kHz or of 8.625 kHz. If the SELT quiet line noise is being reported over a frequency range of 17.664 MHz or lower, SELTQLN_G shall be set to 1. If the SELT quiet line noise is being reported over a frequency range that is greater than 17.664 MHz, SELTQLN_G shall be set to 2. SELT quiet line noise SELTQLN(i * SELTQLN_G * Df) shall be represented as an 8-bit unsigned integer n(i), where i is the subcarrier index i = 0 to NSC-1. The value of SELTQLN(i * SELTQLN_G * Df) shall be defined as SELTQLN(i * SELTQLN_G * Df ) = -23 - (n(i)/2) dBm/Hz. This data format supports a SELTQLN(f) granularity of 0.5 dB and an SELTQLN(f) dynamic range of -150 to -23 dBm/Hz. Unit: 0.5dBm/Hz
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..1024)  

hwBTSSAdslDeltTestTable 1.3.6.1.4.1.2011.6.21.3.1.1.22
This table describes Delt test for adsl2+. The index of this table is ifIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HWBTSSAdslDeltTestEntry

hwBTSSAdslDeltTestEntry 1.3.6.1.4.1.2011.6.21.3.1.1.22.1
This table describes Delt test for adsl2+. The index of this entry is ifIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  HWBTSSAdslDeltTestEntry  

hwBTSSAdslDeltTestOperType 1.3.6.1.4.1.2011.6.21.3.1.1.22.1.1
Delt test operation type. Options: 1. stop(1) - Delt test stop 2. start(2) - Start delt test 3. invalid(-1) - No operation
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER stop(1), start(2), invalid(-1)  

hwBTSSAdslDeltTestOperResult 1.3.6.1.4.1.2011.6.21.3.1.1.22.1.2
Delt test operation result. Options: 1. normal(1) - Delt test is normal 2. fail(2) - Fail in delt test 3. abort(3) - Delt test aborts
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER normal(1), fail(2), abort(3)  

hwBTSSAdslDeltTestResultNo 1.3.6.1.4.1.2011.6.21.3.1.1.22.1.3
Delt test result serial number. Range: 1-255
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32 1..255  

hwBTSSAdslDeltTestResultLastFlag 1.3.6.1.4.1.2011.6.21.3.1.1.22.1.4
Last package flag for test result. Options: 1. false(0) - This is not the last package 2. true(1) - The last package
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER false(0), true(1)  

hwBTSSAdslDeltTestResult 1.3.6.1.4.1.2011.6.21.3.1.1.22.1.5
Delt test result data.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  OCTET STRING Size(0..1500)  

hwBTSSLoopLineToneOprTable 1.3.6.1.4.1.2011.6.21.3.1.1.23
The table hwBTSSLoopLineToneOprTable is used to Loop Line Tone. The index of this table is ifIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwBTSSLoopLineToneOprEntry

hwBTSSLoopLineToneOprEntry 1.3.6.1.4.1.2011.6.21.3.1.1.23.1
The table hwBTSSLoopLineToneOprTable is used to Loop Line Tone. The index of this entry is ifIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwBTSSLoopLineToneOprEntry  

hwBTSSLoopLineToneOprType 1.3.6.1.4.1.2011.6.21.3.1.1.23.1.1
Operation type of BTSS loop line tone Options: 1. check(1) - Indicates that checking the signal tone is started 2. send(2) - Indicates that sending the signal tone is started 3. stopsend(3) - Indicates that stopping sending the signal tone is started
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER check(1), send(2), stopsend(3)  

hwBTSSLoopLineToneIntensity 1.3.6.1.4.1.2011.6.21.3.1.1.23.1.2
Tone intensity of BTSS loop line tone. Options: 1. fivedB(1) - Tone intensity of BTSS is five dB 2. tendB(2) - Tone intensity of BTSS is ten dB 3. fifteendB(3) - Tone intensity of BTSS is fifteen dB
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER fivedB(1), tendB(2), fifteendB(3)  

hwBTSSLoopLineToneBusyFlag 1.3.6.1.4.1.2011.6.21.3.1.1.23.1.3
Tested port force test of BTSS loop line tone. Options: 1. busyNoTest(1) - No test on busy 2. busyTest(2) - Test on busy 3. busystrenTest(3) - Forced test on busy
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER busyNoTest(1), busyTest(2), busystrenTest(3)  

hwBTSSLoopLineToneResult 1.3.6.1.4.1.2011.6.21.3.1.1.23.1.4
Operate result of BTSS loop line tone. Options: 1. succeed(1) - The test of BTSS loop line tone is successful 2. failed(2) - Failed in BTSS loop line tone test
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER succeed(1), failed(2)  

hwBTSSSeltAuxPortCfgTable 1.3.6.1.4.1.2011.6.21.3.1.1.24
This table sets assistance port for SELT. The index of this table is hwBTSSSeltAuxedPortIfIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwBTSSSeltAuxPortCfgEntry

hwBTSSSeltAuxPortCfgEntry 1.3.6.1.4.1.2011.6.21.3.1.1.24.1
This table sets assistance port for SELT. The index of this entry is hwBTSSSeltAuxedPortIfIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwBTSSSeltAuxPortCfgEntry  

hwBTSSSeltAuxedPortIfIndex 1.3.6.1.4.1.2011.6.21.3.1.1.24.1.1
The ifindex of the Auxed port. If there is only one global Auxed port, the value is 65535.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

hwBTSSSeltAuxPortIfIndex 1.3.6.1.4.1.2011.6.21.3.1.1.24.1.2
Assistance port ifIndex
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

hwBTSSSeltAuxPortRowStatus 1.3.6.1.4.1.2011.6.21.3.1.1.24.1.3
Row status(add(4), delete(6)) of the Aux port.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

hwBTSSAdslSeltLevelTable 1.3.6.1.4.1.2011.6.21.3.1.1.25
This table supports the configuration of adsl selt level. The indexes of this table are hwFrameIndex and hwSlotIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwBTSSAdslSeltLevelEntry

hwBTSSAdslSeltLevelEntry 1.3.6.1.4.1.2011.6.21.3.1.1.25.1
This table supports the configuration of adsl selt level. The indexes of this entry are hwFrameIndex and hwSlotIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwBTSSAdslSeltLevelEntry  

hwBTSSAdslSeltLevel 1.3.6.1.4.1.2011.6.21.3.1.1.25.1.1
The level of adsl SELT: 1 Level0; 2 Level1; 3 Level2; 4 Level3. A special value of -1 indicates the level of adsl SELT is invalid.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1 | 1..4  

hwBTSSAdslSeltCalibrationTable 1.3.6.1.4.1.2011.6.21.3.1.1.26
This table describes calibration data of selt test. The index of this table is ifIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HWBTSSAdslSeltCalibrationtEntry

hwBTSSAdslSeltCalibrationEntry 1.3.6.1.4.1.2011.6.21.3.1.1.26.1
This table describes calibration data of selt test. The index of this entry is ifIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  HWBTSSAdslSeltCalibrationtEntry  

hwBTSSAdslSeltCalibrationInvVendorId 1.3.6.1.4.1.2011.6.21.3.1.1.26.1.1
It consists of 8 binary octets, including a provider code.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

hwBTSSAdslSeltCalibrationDataSegment1 1.3.6.1.4.1.2011.6.21.3.1.1.26.1.2
The part 1 of selt calibration data. The unit of selt calibration data is 0.00001.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..8192)  

hwBTSSAdslSeltCalibrationDataSegment2 1.3.6.1.4.1.2011.6.21.3.1.1.26.1.3
The part 2 of selt calibration data. The unit of selt calibration data is 0.00001.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..8192)  

hwBTestTraps 1.3.6.1.4.1.2011.6.21.3.2
OBJECT IDENTIFIER    

hwBTestTrapVbOids 1.3.6.1.4.1.2011.6.21.3.2.1
OBJECT IDENTIFIER    

hwBTestVbOidsReason 1.3.6.1.4.1.2011.6.21.3.2.1.2
OBJECT IDENTIFIER    

hwBTSSCqtOfflineReason 1.3.6.1.4.1.2011.6.21.3.2.1.2.1
Cqt module offline reason. Options: 1. commFail(1) - CQT module communication fail. Resolving method:Check CQT module running normal 2. userReset(2) - User reset command
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER commFail(1), userReset(2)  

hwBTSSRequestID 1.3.6.1.4.1.2011.6.21.3.2.1.2.2
NMS request ID.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

hwBTestAlarmTraps 1.3.6.1.4.1.2011.6.21.3.2.2
OBJECT IDENTIFIER    

hwBTestAlarmTrapsOIDs 1.3.6.1.4.1.2011.6.21.3.2.2.0
OBJECT IDENTIFIER    

hwBTSSCqtOnlineTrap 1.3.6.1.4.1.2011.6.21.3.2.2.0.1
CQT unit online status trap. This notification indicates alarm when CQT unit online. enumFirst: explain: CQT module communication OK resolving method:NA.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwBTSSCqtOfflineTrap 1.3.6.1.4.1.2011.6.21.3.2.2.0.2
CQT unit offline status trap. This notification indicates alarm when CQT unit offline.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwBTestGeneralTraps 1.3.6.1.4.1.2011.6.21.3.2.3
OBJECT IDENTIFIER    

hwBTestGeneralTrapsOIDs 1.3.6.1.4.1.2011.6.21.3.2.3.0
OBJECT IDENTIFIER    

hwBTSSCoStartTrap 1.3.6.1.4.1.2011.6.21.3.2.3.0.1
Start Co test trap. This notification indicates alarm when starting Co test.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwBTSSCoStopTrap 1.3.6.1.4.1.2011.6.21.3.2.3.0.2
Stop Co test trap. This notification indicates alarm when stopping Co test.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwBTSSTestedPortOperTrap 1.3.6.1.4.1.2011.6.21.3.2.3.0.3
Tested port operation trap. This notification indicates alarm when tested port operation.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwBTSSCqtTransTestOperResultTrap 1.3.6.1.4.1.2011.6.21.3.2.3.0.4
Cqt transparent test trap. This notification indicates alarm when starting or stoping Cqt transparent test.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwBTSSCqtTransTestResultTrap 1.3.6.1.4.1.2011.6.21.3.2.3.0.5
Cqt transparent test trap. This notification indicates alarm when reporting the result after Cqt transparent test.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwBTSSLoopLineToneOperTrap 1.3.6.1.4.1.2011.6.21.3.2.3.0.6
loop line tone test result trap: 1:hwBTSSLoopLineToneResult. This notification indicates alarm when reporting the test result of Loop Line Tone.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwBTSSCaptureTrap 1.3.6.1.4.1.2011.6.21.3.2.3.0.7
BTSS capture trap. This trap is sent when BTSS capture result reported.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwBTSSDeltResultDataTrap 1.3.6.1.4.1.2011.6.21.3.2.3.0.8
BTSS delt result trap. This notification indicates alarm when captures result data of BTSS delt test.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE