HUAWEI-COMMTEST-MIB

File: HUAWEI-COMMTEST-MIB.mib (253457 bytes)

Imported modules

HUAWEI-MIB IF-MIB SNMPv2-SMI
SNMPv2-TC HUAWEI-DEVICE-MIB HUAWEI-SNMP-NOTIFICATION-MIB

Imported symbols

huaweiUtility ifIndex Unsigned32
Gauge32 Counter64 Integer32
OBJECT-TYPE MODULE-IDENTITY NOTIFICATION-TYPE
RowStatus DateAndTime TruthValue
hwFrameIndex hwSlotIndex hwTrapSN

Defined Types

HwTestGroupOprEntry  
SEQUENCE    
  hwTestGroupNo Integer32
  hwTestBoardIfIndex Integer32
  hwTestGroupAssistIfIndex Integer32
  hwTestGroupAssistTelNo OCTET STRING
  hwTestGroupRowStatus RowStatus

HwLoopLineTestOprEntry  
SEQUENCE    
  hwLoopLineTestOprType INTEGER
  hwLoopLineTestVoltage INTEGER
  hwLoopLineTestResistance INTEGER
  hwLoopLineTestCapacitance INTEGER
  hwLoopLineTestLoopResistance INTEGER
  hwLoopLineTestPoleResistance INTEGER
  hwLoopLineTestBusyProcFlag INTEGER
  hwLoopLineTestStatus INTEGER
  hwLoopLineTestConclusion INTEGER
  hwLoopLineTestACAG Integer32
  hwLoopLineTestACBG Integer32
  hwLoopLineTestACAB Integer32
  hwLoopLineTestDCAG Integer32
  hwLoopLineTestDCBG Integer32
  hwLoopLineTestDCAB Integer32
  hwLoopLineTestRAG Integer32
  hwLoopLineTestRBG Integer32
  hwLoopLineTestRAB Integer32
  hwLoopLineTestCapAG Integer32
  hwLoopLineTestCapBG Integer32
  hwLoopLineTestCapAB Integer32
  hwLoopLineTestLR Integer32
  hwLoopLineTestRABResPole Integer32
  hwLoopLineTestMSocket INTEGER
  hwLoopLineTestBtssPowerProcFlag INTEGER
  hwLoopLineTestImpedance INTEGER
  hwLoopLineTestImpedanceAB Integer32
  hwLoopLineTestImpedanceBA Integer32
  hwLoopLineTestImpedanceAG Integer32
  hwLoopLineTestImpedanceBG Integer32
  hwLoopLineTestCurrent INTEGER
  hwLoopLineTestACCurrentAG Integer32
  hwLoopLineTestACCurrentBG Integer32
  hwLoopLineTestACCurrentAB Integer32
  hwLoopLineTestDCCurrentAG Integer32
  hwLoopLineTestDCCurrentBG Integer32
  hwLoopLineTestDCCurrentAB Integer32
  hwLoopLineTestLoopCurrent INTEGER
  hwLoopLineTestLC Integer32
  hwLoopLineTestNoise INTEGER
  hwLoopLineTestN Integer32
  hwLoopLineTestPPA INTEGER
  hwLoopLineTestPPAResult INTEGER
  hwLoopLineTestDeferredTime Integer32
  hwLoopLineTestTimeoutProc INTEGER
  hwLoopLineTestReverse Integer32
  hwLoopLineTestUtgAcFreq Integer32
  hwLoopLineTestUrgAcFreq Integer32
  hwLoopLineTestUtrAcFreq Integer32
  hwLoopLineTestItipAc Integer32
  hwLoopLineTestIringAc Integer32
  hwLoopLineTestItipDc Integer32
  hwLoopLineTestIringDc Integer32
  hwLoopLineTestRbattip Integer32
  hwLoopLineTestRbatring Integer32
  hwLoopLineTestRring Integer32
  hwLoopLineTestCsig Integer32
  hwLoopLineTestVzener Integer32
  hwLoopLineTestRzener Integer32
  hwLoopLineTestGtg Integer32
  hwLoopLineTestBtg Integer32
  hwLoopLineTestGrg Integer32
  hwLoopLineTestBrg Integer32
  hwLoopLineTestGtr Integer32
  hwLoopLineTestBtr Integer32
  hwLoopLineTestSIGN TruthValue
  hwLoopLineTestACFEM TruthValue
  hwLoopLineTestDCFEM TruthValue
  hwLoopLineTestONHK TruthValue
  hwLoopLineTestOPEN TruthValue
  hwLoopLineTestSHORT TruthValue
  hwLoopLineTestROH TruthValue
  hwLoopLineTestUtgDcUp Integer32
  hwLoopLineTestUtgDcDown Integer32
  hwLoopLineTestUrgDcUp Integer32
  hwLoopLineTestUrgDcDown Integer32
  hwLoopLineTestUtrPos Integer32
  hwLoopLineTestUtrNeg Integer32
  hwLoopLineTestItgDcUp Integer32
  hwLoopLineTestItgDcDown Integer32
  hwLoopLineTestIrgDcUp Integer32
  hwLoopLineTestIrgDcDown Integer32
  hwLoopLineTestItrPos Integer32
  hwLoopLineTestItrNeg Integer32
  hwLoopLineTestRinger Integer32
  hwLoopLineTestPPARes Integer32
  hwLoopLineTestStartTime DateAndTime
  hwLoopLineTestEndTime DateAndTime
  hwLoopLineTestOprMeasuredFreq INTEGER
  hwLoopLineTestIfIndex Integer32
  hwLoopLineTestRequestID Integer32
  hwLoopLineTestRABPole Integer32
  hwLoopLineTestACAGFlag INTEGER
  hwLoopLineTestACBGFlag INTEGER
  hwLoopLineTestACABFlag INTEGER
  hwLoopLineTestDCAGFlag INTEGER
  hwLoopLineTestDCBGFlag INTEGER
  hwLoopLineTestDCABFlag INTEGER
  hwLoopLineTestRAGFlag INTEGER
  hwLoopLineTestRBGFlag INTEGER
  hwLoopLineTestRABFlag INTEGER
  hwLoopLineTestRABPoleFlag INTEGER
  hwLoopLineTestRABResPoleFlag INTEGER
  hwLoopLineTestCapAGFlag INTEGER
  hwLoopLineTestCapBGFlag INTEGER
  hwLoopLineTestCapABFlag INTEGER
  hwLoopLineTestRbattipFlag INTEGER
  hwLoopLineTestRbatringFlag INTEGER
  hwLoopLineTestRringFlag INTEGER
  hwLoopLineTestCsigFlag INTEGER
  hwLoopLineTestPPAResFlag INTEGER
  hwLoopLineTestVzenerFlag INTEGER
  hwLoopLineTestRzenerFlag INTEGER
  hwLoopLineTestSNMPRab Integer32
  hwLoopLineTestSNMPRabFlag INTEGER
  hwLoopLineTestSNMPRba Integer32
  hwLoopLineTestSNMPRbaFlag INTEGER
  hwLoopLineTestPPAResultFlag INTEGER
  hwLoopLineTestUtgAcFreqFlag INTEGER
  hwLoopLineTestUrgAcFreqFlag INTEGER
  hwLoopLineTestUtrAcFreqFlag INTEGER
  hwLoopLineTestItipAcFlag INTEGER
  hwLoopLineTestIringAcFlag INTEGER
  hwLoopLineTestItipDcFlag INTEGER
  hwLoopLineTestIringDcFlag INTEGER
  hwLoopLineTestGtgFlag INTEGER
  hwLoopLineTestBtgFlag INTEGER
  hwLoopLineTestGrgFlag INTEGER
  hwLoopLineTestBrgFlag INTEGER
  hwLoopLineTestGtrFlag INTEGER
  hwLoopLineTestBtrFlag INTEGER
  hwLoopLineTestSIGNFlag INTEGER
  hwLoopLineTestACFEMFlag INTEGER
  hwLoopLineTestDCFEMFlag INTEGER
  hwLoopLineTestONHKFlag INTEGER
  hwLoopLineTestOPENFlag INTEGER
  hwLoopLineTestSHORTFlag INTEGER
  hwLoopLineTestROHFlag INTEGER
  hwLoopLineTestUtgDcUpFlag INTEGER
  hwLoopLineTestUtgDcDownFlag INTEGER
  hwLoopLineTestUrgDcUpFlag INTEGER
  hwLoopLineTestUrgDcDownFlag INTEGER
  hwLoopLineTestUtrPosFlag INTEGER
  hwLoopLineTestUtrNegFlag INTEGER
  hwLoopLineTestItgDcUpFlag INTEGER
  hwLoopLineTestItgDcDownFlag INTEGER
  hwLoopLineTestIrgDcUpFlag INTEGER
  hwLoopLineTestIrgDcDownFlag INTEGER
  hwLoopLineTestItrPosFlag INTEGER
  hwLoopLineTestItrNegFlag INTEGER
  hwLoopLineTestRingerFlag INTEGER
  hwLoopLineTestLRFlag INTEGER
  hwLoopLineTestDcCurrent INTEGER
  hwLoopLineTestAcCurrent INTEGER
  hwLoopLineTestConductance INTEGER
  hwLoopLineTestSusceptance INTEGER
  hwLoopLineTestAcfrequencyA INTEGER
  hwLoopLineTestAcfrequencyB INTEGER
  hwLoopLineTestCapABH Integer32
  hwLoopLineTestCapABHFlag INTEGER
  hwLoopLineTestGtrH Integer32
  hwLoopLineTestGtrHFlag INTEGER
  hwLoopLineTestBtrH Integer32
  hwLoopLineTestBtrHFlag INTEGER
  hwLoopLineTestABDcCurrent Integer32
  hwLoopLineTestABDcCurrentFlag INTEGER
  hwLoopLineTestBADcCurrent Integer32
  hwLoopLineTestBADcCurrentFlag INTEGER
  hwLoopLineTestABAcCurrent Integer32
  hwLoopLineTestABAcCurrentFlag INTEGER
  hwLoopLineTestBAAcCurrent Integer32
  hwLoopLineTestBAAcCurrentFlag INTEGER
  hwLoopLineTestCSfrequencyForTest Integer32
  hwLoopLineTestCSfrequencyForTestFlag INTEGER
  hwLoopLineTestImpedanceForTest Integer32
  hwLoopLineTestImpedanceForTestFlag INTEGER
  hwLoopLineTestMaxVForSignature Integer32
  hwLoopLineTestMaxVForSignatureFlag INTEGER
  hwLoopLineTestAGMaxVForTest Integer32
  hwLoopLineTestAGMaxVForTestFlag INTEGER
  hwLoopLineTestAGMinVForTest Integer32
  hwLoopLineTestAGMinVForTestFlag INTEGER
  hwLoopLineTestBGMaxVForTest Integer32
  hwLoopLineTestBGMaxVForTestFlag INTEGER
  hwLoopLineTestBGMinVForTest Integer32
  hwLoopLineTestBGMinVForTestFlag INTEGER
  hwLoopLineTestABMaxVForTest Integer32
  hwLoopLineTestABMaxVForTestFlag INTEGER
  hwLoopLineTestABMinVForTest Integer32
  hwLoopLineTestABMinVForTestFlag INTEGER
  hwLoopLineTestAGMaxCForTest Integer32
  hwLoopLineTestAGMaxCForTestFlag INTEGER
  hwLoopLineTestAGMinCForTest Integer32
  hwLoopLineTestAGMinCForTestFlag INTEGER
  hwLoopLineTestBGMaxCForTest Integer32
  hwLoopLineTestBGMaxCForTestFlag INTEGER
  hwLoopLineTestBGMinCForTest Integer32
  hwLoopLineTestBGMinCForTestFlag INTEGER
  hwLoopLineTestABMaxCForTest Integer32
  hwLoopLineTestABMaxCForTestFlag INTEGER
  hwLoopLineTestABMaxNegCForTest Integer32
  hwLoopLineTestABMaxNegCForTestFlag INTEGER
  hwLoopLineTestLineALength Integer32
  hwLoopLineTestLineBLength Integer32
  hwLoopLineTestTermimalConcusion INTEGER
  hwLoopLineTestMoreDataFlag INTEGER
  hwLoopLineTestCtrLV Integer32
  hwLoopLineTestCtrLVFlag INTEGER
  hwLoopLineTestCtrHV Integer32
  hwLoopLineTestCtrHVFlag INTEGER
  hwLoopLineTestCtrAc Integer32
  hwLoopLineTestCtrAcFlag INTEGER
  hwLoopLineTestRtgSer Integer32
  hwLoopLineTestRtgSerFlag INTEGER
  hwLoopLineTestRrgSer Integer32
  hwLoopLineTestRrgSerFlag INTEGER
  hwLoopLineTestRtrSer Integer32
  hwLoopLineTestRtrSerFlag INTEGER
  hwLoopLineTestUtgAcAdmit Integer32
  hwLoopLineTestUtgAcAdmitFlag INTEGER
  hwLoopLineTestUrgAcAdmit Integer32
  hwLoopLineTestUrgAcAdmitFlag INTEGER
  hwLoopLineTestUtrAcAdmit Integer32
  hwLoopLineTestUtrAcAdmitFlag INTEGER
  hwLoopLineTestCapterminal INTEGER
  hwLoopLineTestCapterminalFlag INTEGER

HwMeterTestOprEntry  
SEQUENCE    
  hwMeterTestOprType INTEGER
  hwMeterTestItem INTEGER
  hwMeterTestStatus INTEGER
  hwMeterTestBusyFlag INTEGER

HwTestBoardDiagnoseTestOprEntry  
SEQUENCE    
  hwTestBoardDiagnoseTestOprType INTEGER
  hwTestBoardDiagnoseTestResult INTEGER
  hwTestBoardDiagnoseTestRAM INTEGER
  hwTestBoardDiagnoseTestVoltage INTEGER
  hwTestBoardDiagnoseTestResistance INTEGER
  hwTestBoardDiagnoseTestSignal INTEGER
  hwTestBoardDiagnoseTestDTMF INTEGER
  hwTestBoardDiagnoseTestRing INTEGER
  hwTestBoardDiagnoseTestOnOffHook INTEGER
  hwTestBoardDiagnoseTestPole INTEGER
  hwTestBoardDiagnoseTestISDNU INTEGER
  hwTestBoardDiagnoseTestBitErrCode INTEGER
  hwTestBoardDiagnoseTestCapacitance INTEGER

HwTestBoardStatusQueryOprEntry  
SEQUENCE    
  hwTestBoardStatusQueryOprType INTEGER
  hwTestBoardStatusQueryResult INTEGER
  hwTestBoardStatusQueryVersion Integer32
  hwTestBoardStatusQueryTestItem INTEGER
  hwTestBoardStatusTestedBoardIfIndex Integer32

HwSearchingToneOprEntry  
SEQUENCE    
  hwSearchingToneOprType INTEGER
  hwSearchingToneLevel Integer32
  hwSearchingToneFrequency Integer32
  hwSearchingToneDurationTime Integer32
  hwSearchingToneRemainingTime Integer32
  hwSearchingToneBusyProcFlag INTEGER

HwLoopLineTestCalibrationEntry  
SEQUENCE    
  hwLoopLineTestAGCalibration Integer32
  hwLoopLineTestBGCalibration Integer32
  hwLoopLineTestABCalibration Integer32

HwLoopLineTestMeltVerEntry  
SEQUENCE    
  hwLoopLineTestMeltFactory OCTET STRING
  hwLoopLineTestMeltChip OCTET STRING
  hwLoopLineTestMeltFirmwareVer OCTET STRING

HwONTPotsTestOprEntry  
SEQUENCE    
  hwONTPotsTestONTIndex Integer32
  hwONTPotsTestONTPstnPortIndex Integer32
  hwONTPotsTestOprType INTEGER
  hwONTPotsTestItem INTEGER
  hwONTPotsTestBusyProcFlag INTEGER
  hwONTPotsTestT1Threshold Integer32
  hwONTPotsTestT2Threshold Integer32
  hwONTPotsTestT3Threshold Integer32
  hwONTPotsTestT4Threshold Integer32
  hwONTPotsTestDtmfDigit INTEGER
  hwONTPotsTestDialType INTEGER
  hwONTPotsTestDialToneFreq1 Integer32
  hwONTPotsTestDialToneFreq2 Integer32
  hwONTPotsTestDialToneFreq3 Integer32
  hwONTPotsTestDialToneEnergyThreshold Integer32
  hwONTPotsTestIdleChannelEnergyThreshold Integer32
  hwONTPotsTestDCHazardousVoltThreshold Integer32
  hwONTPotsTestACHazardousVoltThreshold Integer32
  hwONTPotsTestDCForeignVoltThreshold Integer32
  hwONTPotsTestACForeignVoltThreshold Integer32
  hwONTPotsTestAGBGResistanceThreshold Integer32
  hwONTPotsTestABResistanceThreshold Integer32
  hwONTPotsTestRingerEquivMinThreshold Integer32
  hwONTPotsTestRingerEquivMaxThreshold Integer32
  hwONTPotsTestMLTResult INTEGER
  hwONTPotsTestHazardousVoltResult INTEGER
  hwONTPotsTestEMFResult INTEGER
  hwONTPotsTestResistacneResult INTEGER
  hwONTPotsTestOffHookResult INTEGER
  hwONTPotsTestRingerResult INTEGER
  hwONTPotsTestNT1DCSignalResult INTEGER
  hwONTPotsTestSelfTestResult INTEGER
  hwONTPotsTestDrawDialToneResult INTEGER
  hwONTPotsTestBreakDialToneResult INTEGER
  hwONTPotsTestQuietEnergyResult INTEGER
  hwONTPotsTestDialToneEnergyResult INTEGER
  hwONTPotsTestLoopDCAGVoltResult INTEGER
  hwONTPotsTestLoopDCBGVoltResult INTEGER
  hwONTPotsTestLoopACAGVoltResult INTEGER
  hwONTPotsTestLoopACBGVoltResult INTEGER
  hwONTPotsTestLoopResistanceAGResult INTEGER
  hwONTPotsTestLoopResistanceBGResult INTEGER
  hwONTPotsTestLoopResistanceABResult INTEGER
  hwONTPotsTestLoopRingerLoadTestResult INTEGER
  hwONTPotsTestDrawDialToneTimeValue Integer32
  hwONTPotsTestBreakDialToneTimeValue Integer32
  hwONTPotsTestQuietEnergyValue Integer32
  hwONTPotsTestDialToneEnergyValue Integer32
  hwONTPotsTestLoopDCAGVoltValue Integer32
  hwONTPotsTestLoopDCBGVoltValue Integer32
  hwONTPotsTestLoopACAGVoltValue Integer32
  hwONTPotsTestLoopACBGVoltValue Integer32
  hwONTPotsTestLoopResistanceAGValue Integer32
  hwONTPotsTestLoopResistanceBGValue Integer32
  hwONTPotsTestLoopResistanceABValue Integer32
  hwONTPotsTestLoopRingerLoadTestValue Integer32
  hwONTPotsTestSubscriberLineTestResult INTEGER
  hwONTPotsTestLoopDCABVoltValue Integer32
  hwONTPotsTestLoopACABVoltValue Integer32
  hwONTPotsTestLoopAGCapacitanceValue Integer32
  hwONTPotsTestLoopBGCapacitanceValue Integer32
  hwONTPotsTestLoopABCapacitanceValue Integer32

HwPortTestingListOprEntry  
SEQUENCE    
  hwMeltTestingPortList BITS
  hwSearchToneTestingPortList BITS

HwWettingCurrentOprEntry  
SEQUENCE    
  hwWettingCurrentOprStatus INTEGER
  hwWettingCurrentOprWorkingVoltage Integer32
  hwWettingCurrentOprMaximumVoltage Integer32
  hwWettingCurrentOprSlope Integer32

Defined Values

hwTestCommon 1.3.6.1.4.1.2011.6.21.1
This MIB is used for Metallic line test(MELT).Melt test is a common line status test method,used to test whether the copper twisted pair from the service board to the phone set is normal. Common MELT operations include starting a MELT test, querying the test result, querying the calibration data, and starting and stopping a searching tone test.
MODULE-IDENTITY    

hwTest 1.3.6.1.4.1.2011.6.21
OBJECT IDENTIFIER    

hwTestCommonMib 1.3.6.1.4.1.2011.6.21.1.1
OBJECT IDENTIFIER    

hwTestCommonMIBObjects 1.3.6.1.4.1.2011.6.21.1.1.1
OBJECT IDENTIFIER    

hwTestGroupOprTable 1.3.6.1.4.1.2011.6.21.1.1.1.1
Table of the test group: It provides the number of the test group to which a shelf of the device corresponds. It is uniquely identified by the number of the test group. Multiple shelves can share a test board. A test group corresponds to a test board. The number of a test group is the same as the number of the shelf that houses the test board to which the test group corresponds. The index of this table is hwTestGroupNo.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwTestGroupOprEntry

hwTestGroupOprEntry 1.3.6.1.4.1.2011.6.21.1.1.1.1.1
Table of the test group: It provides the number of the test group to which a shelf of the device corresponds. It is uniquely identified by the number of the test group. Multiple shelves can share a test board. A test group corresponds to a test board. The number of a test group is the same as the number of the shelf that houses the test board to which the test group corresponds. The index of this entry is hwTestGroupNo.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwTestGroupOprEntry  

hwTestGroupNo 1.3.6.1.4.1.2011.6.21.1.1.1.1.1.1
Test group number. The MD5500 supports the number that ranges from 0 to 240. The MA5100 supports the number that ranges from 0 to 4. The MA5300 supports the number that ranges from 0 to 63.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..240  

hwTestBoardIfIndex 1.3.6.1.4.1.2011.6.21.1.1.1.1.1.2
Test board IfIndex.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

hwTestGroupAssistIfIndex 1.3.6.1.4.1.2011.6.21.1.1.1.1.1.3
TestGroupAssist port IfIndex.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

hwTestGroupAssistTelNo 1.3.6.1.4.1.2011.6.21.1.1.1.1.1.4
Assistant telephone number. The maximum length is 16 Octets.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..16)  

hwTestGroupRowStatus 1.3.6.1.4.1.2011.6.21.1.1.1.1.1.5
Present operation status of a row. Options: 1. active(1), -the present operation status of the row is active 2. notInService(2), -the present operation status of the row is notInService 3. notReady(3), -the present operation status of the row is notReady 4. createAndGo(4), -the present operation status of the row is createAndGo 5. createAndWait(5), -the present operation status of the row is createAndWait 6. destroy(6) -the present operation status of the row is destroy
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

hwLoopLineTestOprTable 1.3.6.1.4.1.2011.6.21.1.1.1.2
This table is used for enabling a subscriber line test and obtaining the test result after a test is complete. The subscriber line test function can be used for obtaining the performance information about a subscriber line, such as capacity and resistance. Users can learn about the conditions of the line by comparing such information with standard data. The index of this table is ifindex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwLoopLineTestOprEntry

hwLoopLineTestOprEntry 1.3.6.1.4.1.2011.6.21.1.1.1.2.1
This table is used for enabling a subscriber line test and obtaining the test result after a test is complete. The subscriber line test function can be used for obtaining the performance information about a subscriber line, such as capacity and resistance. Users can learn about the conditions of the line by comparing such information with standard data. The index of this entry is ifindex.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwLoopLineTestOprEntry  

hwLoopLineTestOprType 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.1
MELT operation type Options: 1. stop(1) -stop a MELT test 2. start(2) -start a MELT test 3. invalid(-1) -invalid value
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER stop(1), start(2), invalid(-1)  

hwLoopLineTestVoltage 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.2
Indicates whether a voltage exists on the line under test. Options: 1. notest(1) -the voltage does not exist on the line under test 2. test(2) -the voltage exists on the line under test 3. invalid(-1) -invalid value Default: notest(1)
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notest(1), test(2), invalid(-1)  

hwLoopLineTestResistance 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.3
Indicates whether resistance exists on the line under test. Options: 1. notest(1) -resistance does not exist on the line under test 2. test(2) -resistance exists on the line under test 3. invalid(-1) -invalid value Default: notest(1)
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notest(1), test(2), invalid(-1)  

hwLoopLineTestCapacitance 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.4
Indicates whether capacitance exists on the line under test. Options: 1. notest(1) -capacitance does not exist on the line under test 2. test(2) -capacitance exists on the line under test 3. invalid(-1) -invalid value Default: notest(1)
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notest(1), test(2), invalid(-1)  

hwLoopLineTestLoopResistance 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.5
Indicates whether loop resistance exists on the line under test. Options: 1. notest(1) -loop resistance does not exist on the line under test 2. test(2) -loop resistance exists on the line under test 3. invalid(-1) -invalid value Default: notest(1)
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notest(1), test(2), invalid(-1)  

hwLoopLineTestPoleResistance 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.6
Indicates whether pole resistance exists on the line under test. Options: 1. notest(1) -Pole resistance does not exist on the line under test 2. test(2) -Pole resistance exists on the line under test 3. invalid(-1) -invalid value Default: notest(1)
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notest(1), test(2), invalid(-1)  

hwLoopLineTestBusyProcFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.7
Identify whether to start a test when the line is busy. The system will excecute a corresponding operation according to the configuration that a user specifies, for example, to cancel the test or to force to test. Options: 1. busyNoTest(1) -perform no test when a port is busy 2. busyTest(2) -perform a remedy test when a port is busy 3. busystrenTest(3) -force to test when a port is busy 4. deferredTest(4) -defer a test when a port is busy 5. invalid(-1) -invalid value Default: busyTest(1) If the value of this leaf is deferredTest(4), both hwLoopLineTestDeferredTime and hwLoopLineTestTimeoutProc must be set.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER busyNoTest(1), busyTest(2), busystrenTest(3), deferredTest(4), invalid(-1)  

hwLoopLineTestStatus 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.8
Indicates the result of MELT test. Options: 1. normal(1) -the MELT test is successful 2. testFail(2) -the MELT test fails 3. portBusy(3) -the MELT test port is busy 4. testOutOfTime(4) -the MELT test times out 5. testingAbnormal(5) -the MELT test is abnormal 6. broadbandtesting(6)-the MELT test is broadbandtesting 7. capturefail(7) -the MELT test fails to capture 8. notratb(8) -the relay transfer board of the MELT test does not exist 9. testcanceled(9) -the MELT test is canceled 10. invalid(-1) -invalid value
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), testFail(2), portBusy(3), testOutOfTime(4), testingAbnormal(5), broadbandtesting(6), capturefail(7), notratb(8), testcanceled(9), invalid(-1)  

hwLoopLineTestConclusion 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.9
MELT test conclusion Options: 1. normal(1) -the test conclusion is normal 2. meetLine(2) -the test conclusion is meetLine 3. aLineMix(3) -the test conclusion is aLineMix 4. bLineMix(4) -the test conclusion is bLineMix 5. doubleMix(5) -the test conclusion is doubleMix 6. aLineEarth(6) -the test conclusion is aLineEarth 7. bLineEarth(7) -the test conclusion is bLineEarth 8. doublelineearth(8) -the test conclusion is doublelineearth 9. selfMix(9) -the test conclusion is selfMix 10. abLine(10) -the test conclusion is abLine 11. aLineFree(11) -the test conclusion is aLineFree 12. bLineEarthFree(12) -the test conclusion is bLineEarthFree 13. doubleLineEarthFree(13) -the test conclusion is doubleLineEarthFree 14. abLineFree(14) -the test conclusion is abLineFree 15. killLine(15) -the test conclusion is killLine 16. noPutDownTele(16) -the test conclusion is noPutDownTele 17. unknow(17) -the test conclusion is unknow 18. selfMixinMDF(18) -the test conclusion is selfMixinMDF 19. selfMixoutMDF(19) -the test conclusion is selfMixoutMDF 20. cutLineinMDF(20) -the test conclusion is cutLineinMDF 21. cutLineoutMDF(21) -the test conclusion is cutLineoutMDF 22. dCvoltagePowerFeed(30) -the test conclusion is dCvoltagePowerFeed 23. aCvoltageRinging(31) -the test conclusion is aCvoltageRinging 24. dCvoltageOffhook(32) -the test conclusion is dCvoltageOffhook 25. dCvoltage(33) -the test conclusion is dCvoltage 26. aCvoltage(34) -the test conclusion is aCvoltage 27. abImpedance(35) -the test conclusion is abImpedance 28. baImpedance(36) -the test conclusion is baImpedance 29. agImpedance(37) -the test conclusion is agImpedance 30. bgImpedance(38) -the test conclusion is bgImpedance 31. agACCurrent(39) -the test conclusion is agACCurrent 32. bgACCurrent(41) -the test conclusion is bgACCurrent 33. abACCurrent(42) -the test conclusion is abACCurrent 34. agDCCurrent(43) -the test conclusion is agDCCurrent 35. bgDCCurrent(44) -the test conclusion is bgDCCurrent 36. abDCCurrent(45) -the test conclusion is abDCCurrent 37. loopCurrent(46) -the test conclusion is loopCurrent 38. noise(47) -the test conclusion is noise 39. abRFaultId(91) -the test conslusion is ab Line all fault 40. aRFaultId(92) -the test conslusion is a Line fault 41. bRFaultId(93) -the test conslusion is b Line fault 42. abLeakId(94) -the test conslusion is ab Line all leak 43. aLeakId(95) -the test conslusion is a Line leak 44. bLeakId(96) -the test conslusion is b line leak 45. abFvacLevelH(97) -the test conslusion is ab dangerous AC to ground 46. aFvacLevelH(98) -the test conslusion is a dangerous AC to ground 47. bFvacLevelH(99) -the test conslusion is b dangerous AC to ground 48. abFvacLevelI(100) -the test conslusion is ab EMF AC to ground 49. aFvacLevelI(101) -the test conslusion is a EMF AC to ground 50. bFvacLevelI(102) -the test conslusion is b EMF AC to ground 51. abFvacLevelO(103) -the test conslusion is ab other dangerous AC to ground 52. aFvacLevelO(104) -the test conslusion is a other dangerous AC to ground 53. bFvacLevelO(105) -the test conslusion is b other dangerous AC to ground 54. abFvDcLevelH(106) -the test conslusion is ab dangerous DC to ground 55. aFvDcLevelH(107) -the test conslusion is a dangerous DC to ground 56. bFvDcLevelH(108) -the test conslusion is b dangerous DC to ground 57. abFvDcLevelI(109) -the test conslusion is ab EMF DC to ground 58. aFvDcLevelI(110) -the test conslusion is a EMF DC to ground 59. bFvDcLevelI(111) -the test conslusion is b EMF DC to ground 60. abFvDcLevelO(112) -the test conslusion is ab other dangerous DC to ground 61. aFvDcLevelO(113) -the test conslusion is a other dangerous DC to ground 62. bFvDcLevelO(114) -the test conslusion is b other dangerous DC to ground 63. fesIdPPA(115) -the test conslusion is ab PPA 64. fesIdPPAInv(116) -the test conslusion is ab reverse PPA 65. fesId2PPA(117) -the test conslusion is ab two PPA 66. fesId2PPAInv(118) -the test conslusion is ab two reverse PPA 67. etsiXdslSignature(119) -the test conslusion is ETSI XDSL Signature 68. fetIdEr(120) -the test conslusion is exist electronic ring terminal 69. abreak(121) -the test conslusion is a line break 70. bbreak(122) -the test conslusion is b line break 71. abreakInMDF(123) -the test conslusion is a line break InMDF 72. bbreakInMDF(124) -the test conslusion is b line break InMDF 73. abreakOutMDF(125) -the test conslusion is a line break OutMDF 74. bbreakOutMDF(126) -the test conslusion is b line break OutMDF 75. invalid(-1) -the test conclusion is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), meetLine(2), aLineMix(3), bLineMix(4), doubleMix(5), aLineEarth(6), bLineEarth(7), doublelineearth(8), selfMix(9), abLine(10), aLineFree(11), bLineEarthFree(12), doubleLineEarthFree(13), abLineFree(14), killLine(15), noPutDownTele(16), unknow(17), selfMixinMDF(18), selfMixoutMDF(19), cutLineinMDF(20), cutLineoutMDF(21), dCvoltagePowerFeed(30), aCvoltageRinging(31), dCvoltageOffhook(32), dCvoltage(33), aCvoltage(34), abImpedance(35), baImpedance(36), agImpedance(37), bgImpedance(38), agACCurrent(39), bgACCurrent(41), abACCurrent(42), agDCCurrent(43), bgDCCurrent(44), abDCCurrent(45), loopCurrent(46), noise(47), abRFaultId(91), aRFaultId(92), bRFaultId(93), abLeakId(94), aLeakId(95), bLeakId(96), abFvacLevelH(97), aFvacLevelH(98), bFvacLevelH(99), abFvacLevelI(100), aFvacLevelI(101), bFvacLevelI(102), abFvacLevelO(103), aFvacLevelO(104), bFvacLevelO(105), abFvDcLevelH(106), aFvDcLevelH(107), bFvDcLevelH(108), abFvDcLevelI(109), aFvDcLevelI(110), bFvDcLevelI(111), abFvDcLevelO(112), aFvDcLevelO(113), bFvDcLevelO(114), fesIdPPA(115), fesIdPPAInv(116), fesId2PPA(117), fesId2PPAInv(118), etsiXdslSignature(119), fetIdEr(120), abreak(121), bbreak(122), abreakInMDF(123), bbreakInMDF(124), abreakOutMDF(125), bbreakOutMDF(126), invalid(-1)  

hwLoopLineTestACAG 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.10
Indicates the A->ground AC voltage. Unit: mV
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestACBG 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.11
Indicates the B->ground AC voltage. Unit: mV
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestACAB 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.12
Indicates the A->B AC voltage. Unit: mV
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestDCAG 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.13
Indicates the A->ground DC voltage. Unit: mV
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestDCBG 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.14
Indicates the B->ground DC voltage. Unit: mV
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestDCAB 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.15
Indicates the A->B DC voltage. Unit: mV
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestRAG 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.16
Indicates the A->ground insulation resistance. Unit: ohm
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestRBG 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.17
Indicates the B->ground insulation resistance. Unit: ohm
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestRAB 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.18
Indicates the A->B insulation resistance. Unit: ohm
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestCapAG 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.19
Indicates the A->ground capacitance. Unit: nF
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestCapBG 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.20
Indicates the B->ground capacitance. Unit: nF
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestCapAB 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.21
Indicates the A->B capacitance. Unit: nF
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestLR 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.22
Indicates the loop resistance. Unit: ohm
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestRABResPole 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.23
Indicates the A->B polarity reversal resistance. Unit: ohm
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestMSocket 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.24
Indicates the M-socket connection. Options: 1. notconnected(1) -the M-socket is not connected 2. connected(2) -the M-socket is connected 3. aBReversed(3) -the wire A and wire B are reversed
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notconnected(1), connected(2), aBReversed(3)  

hwLoopLineTestBtssPowerProcFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.25
Loop line test-BTSS line with power processing. Options: 1. noTest(1) -not test 2. test(2) -test 3. invalid(-1) -invalid value
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER noTest(1), test(2), invalid(-1)  

hwLoopLineTestImpedance 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.26
Loop line test-impedance. Options: 1. notest(1) -not test 2. test(2) -test
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notest(1), test(2)  

hwLoopLineTestImpedanceAB 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.27
A->B impedance (unit: ohm)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestImpedanceBA 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.28
B->A impedance (unit: ohm)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestImpedanceAG 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.29
A->ground impedance (unit: ohm)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestImpedanceBG 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.30
B->ground impedance (unit: ohm)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestCurrent 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.31
Loop line test-current. Options: 1. notest(1) -not test 2. test(2) -test
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notest(1), test(2)  

hwLoopLineTestACCurrentAG 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.32
A->ground AC current (unit: mA)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestACCurrentBG 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.33
B->ground AC current (unit: mA)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestACCurrentAB 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.34
AB AC current (unit: mA)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestDCCurrentAG 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.35
A->ground DC current (unit: mA)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestDCCurrentBG 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.36
B->ground DC current (unit: mA)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestDCCurrentAB 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.37
AB DC current (unit: mA)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestLoopCurrent 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.38
Loop line test-loop current. Options: 1. notest(1) -not test 2. test(2) -test
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notest(1), test(2)  

hwLoopLineTestLC 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.39
Loop current (unit: uA)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestNoise 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.40
Loop line test-noise. Options: 1. notest(1) -not test 2. test(2) -test
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notest(1), test(2)  

hwLoopLineTestN 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.41
Noise (unit: dBm)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestPPA 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.42
Indicates whether PPA exists on the line under test. Options: 1. notest(1) -PPA does not exist on the line under test 2. test(2) -PPA exists on the line under test 3. invalid(-1) -invalid value Default: notest(1)
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notest(1), test(2), invalid(-1)  

hwLoopLineTestPPAResult 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.43
Indicates whether the PPA exists. Options: 1. noexist(1) -PPA does not exist 2. exist(2) -PPA exists 3. inverseexist(3) -PPA inverse exists 4. invalid(-1) -invalid value
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noexist(1), exist(2), inverseexist(3), invalid(-1)  

hwLoopLineTestDeferredTime 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.44
Indicates the deferred time. Unit: minute This leaf is valid only when the value of hwLoopLineTestBusyProcFlag is DeferredTest(4). Default: 30
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -1 | 1..1440  

hwLoopLineTestTimeoutProc 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.45
Indicates the timeout processing. Options: 1. notest(1) -if the deferred time times out and the port is still busy the test will be canceled 2. test(2) -if the deferred time times out and the port is still busy the test will be forcedly started 3. invalid(-1) -invalid value This leaf is valid only when the value of hwLoopLineTestBusyProcFlag is DeferredTest(4).
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notest(1), test(2), invalid(-1)  

hwLoopLineTestReverse 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.46
Reverse flag (0:normal test 1:reverse test)
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

hwLoopLineTestUtgAcFreq 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.47
Frequency of foreign AC voltage source coupled to tip via Zbat_tip impedance. Unit: Hz
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestUrgAcFreq 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.48
Frequency of foreign AC voltage source coupled to ring via Zbat_ring impedance. Unit:Hz
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestUtrAcFreq 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.49
Frequency of foreign AC voltage source coupled to tip-ring via Zbat_tipring impedance. Unit:Hz
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestItipAc 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.50
AC foreign current on the tip wire. Unit:uA
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestIringAc 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.51
AC foreign current on the ring wire. Unit:uA
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestItipDc 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.52
DC foreign current on the tip wire. Unit:uA
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestIringDc 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.53
DC foreign current on the ring wire. Unit:uA
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestRbattip 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.54
In presence of a foreign voltage, the equivalent coupling resistance of wire A. Unit:ohm
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestRbatring 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.55
In presence of a foreign voltage, the equivalent coupling resistance of wire B. Unit:ohm
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestRring 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.56
Resistance in series with the ring capacitance, for example when a ringer load or a passive R-C signature terminates the loop. It also includes the cable resistance R line but it does not include the 24 k feeding resistance. Unit: ohm
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestCsig 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.57
Capacitance of an xDSL signal. Unit: nF
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestVzener 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.58
Zener diode threshold in the case of an off-hook phone. Unit: mV
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestRzener 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.59
DC tip-ring resistance measured in the case of an off-hook phone. Unit: ohm
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestGtg 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.60
Aggregate a->ground conductance. Unit: nS
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestBtg 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.61
Aggregate a->ground susceptance. Unit: nS
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestGrg 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.62
Aggregate b->ground conductance. Unit: nS
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestBrg 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.63
Aggregate b->ground susceptance. Unit: nS
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestGtr 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.64
Aggregate a->b conductance. Unit: nS
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestBtr 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.65
Aggregate a->b susceptance. Unit: nS
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestSIGN 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.66
Indicates the ETSI xDSL Signature is detected or not.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

hwLoopLineTestACFEM 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.67
Indicates the presence of an AC foreign voltage above the threshold defined by ACFEMmin. By reading the results of the foreign voltage test, it is possible to determine whether the foreign electromotive force source has been coupled to tip, ring or differentially between tip-ring.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

hwLoopLineTestDCFEM 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.68
Indicates the presence of a DC foreign voltage above the threshold defined by DCFEMmin. By reading the results of the foreign voltage test, it is possible to determine whether the foreign electromotive force source has been coupled to tip, ring or differentially between tip-ring.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

hwLoopLineTestONHK 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.69
Indicates the presens of a phone in the on-hook state.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

hwLoopLineTestOPEN 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.70
Indicates a->b resistance exceeds the threshold.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

hwLoopLineTestSHORT 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.71
Indicates that the insulation resistance is small.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

hwLoopLineTestROH 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.72
Indicates a phone in the off-hook state.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

hwLoopLineTestUtgDcUp 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.73
Indicates the a->ground highest measurement DC voltage. Unit: mV
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestUtgDcDown 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.74
Indicates the a->ground lowest measurement DC voltage. Unit: mV
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestUrgDcUp 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.75
Indicates the b->ground highest measurement DC voltage. Unit: mV
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestUrgDcDown 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.76
Indicates the b->ground lowest measurement DC voltage. Unit: mV
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestUtrPos 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.77
Indicates the a->b positive measurement DC voltage. Unit: mV
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestUtrNeg 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.78
Indicates the b->a measurement DC voltage. Unit: mV
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestItgDcUp 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.79
Indicates the current mapping the A-wire highest voltage for test. Unit: uA
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestItgDcDown 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.80
Indicates the current mapping the A-wire lowest voltage for test. Unit: uA
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestIrgDcUp 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.81
Indicates the current mapping the B-wire highest voltage for test. Unit: uA
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestIrgDcDown 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.82
Indicates the current mapping the B-wire lowest voltage for test. Unit: uA
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestItrPos 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.83
Indicates the current mapping the A->B positive voltage for test. Unit: uA
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestItrNeg 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.84
Indicates the current mapping the A->B negative voltage for test. Unit: uA
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestRinger 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.85
Indicates the detected ringer.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestPPARes 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.86
Indicates the resistance of PPA. Unit: ohm
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestStartTime 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.87
Indicates the start time and date of the MELT test.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

hwLoopLineTestEndTime 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.88
Indicates the end time and date of the MELT test.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

hwLoopLineTestOprMeasuredFreq 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.89
Indicates the measured frequency for complex impedance. Options: 1. frequency25Hz(0) -25 Hz 2. frequency275Hz(1) -275 Hz 3. invalid(-1) -invalid value Default: frequency25Hz(0)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER frequency25Hz(0), frequency275Hz(1), invalid(-1)  

hwLoopLineTestIfIndex 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.90
Port IfIndex.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestRequestID 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.91
Request ID. The value is the fourth parameter in the trap message.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestRABPole 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.92
Indicates the A->B polarity resistance. Unit: ohm
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestACAGFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.93
Indicates whether the value of hwLoopLineTestACAG is valid. Options: 1. valid(1) -the value of hwLoopLineTestACAG is valid 2. invalid(2) -the value of hwLoopLineTestACAG is invalid 3. notsupport(3) -the value of hwLoopLineTestACAG is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestACBGFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.94
Indicates whether the value of hwLoopLineTestACBG is valid. Options: 1. valid(1) -the value of hwLoopLineTestACBG is valid 2. invalid(2) -the value of hwLoopLineTestACBG is invalid 3. notsupport(3) -the value of hwLoopLineTestACBG is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestACABFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.95
Indicates whether the value of hwLoopLineTestACAB is valid. Options: 1. valid(1) -the value of hwLoopLineTestACAB is valid 2. invalid(2) -the value of hwLoopLineTestACAB is invalid 3. notsupport(3) -the value of hwLoopLineTestACAB is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestDCAGFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.96
Indicates whether the value of hwLoopLineTestDCAG is valid. Options: 1. valid(1) -the value of hwLoopLineTestDCAG is valid 2. invalid(2) -the value of hwLoopLineTestDCAG is invalid 3. notsupport(3) -the value of hwLoopLineTestDCAG is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestDCBGFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.97
Indicates whether the value of hwLoopLineTestDCBG is valid. Options: 1. valid(1) -the value of hwLoopLineTestDCBG is valid 2. invalid(2) -the value of hwLoopLineTestDCBG is invalid 3. notsupport(3) -the value of hwLoopLineTestDCBG is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestDCABFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.98
Indicates whether the value of hwLoopLineTestDCAB is valid. Options: 1. valid(1) -the value of hwLoopLineTestDCAB is valid 2. invalid(2) -the value of hwLoopLineTestDCAB is invalid 3. notsupport(3) -the value of hwLoopLineTestDCAB is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestRAGFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.99
Indicates whether the value of hwLoopLineTestRAG is valid. Options: 1. valid(1) -the value of hwLoopLineTestRAG is valid 2. invalid(2) -the value of hwLoopLineTestRAG is invalid 3. notsupport(3) -the value of hwLoopLineTestRAG is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestRBGFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.100
Indicates whether the value of hwLoopLineTestRBG is valid. Options: 1. valid(1) -the value of hwLoopLineTestRBG is valid 2. invalid(2) -the value of hwLoopLineTestRBG is invalid 3. notsupport(3) -the value of hwLoopLineTestRBG is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestRABFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.101
Indicates whether the value of hwLoopLineTestRAB is valid. Options: 1. valid(1) -the value of hwLoopLineTestRAB is valid 2. invalid(2) -the value of hwLoopLineTestRAB is invalid 3. notsupport(3) -the value of hwLoopLineTestRAB is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestRABPoleFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.102
Indicates whether the value of hwLoopLineTestRABPole is valid. Options: 1. valid(1) -the value of hwLoopLineTestRABPole is valid 2. invalid(2) -the value of hwLoopLineTestRABPole is invalid 3. notsupport(3) -the value of hwLoopLineTestRABPole is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestRABResPoleFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.103
Indicates whether the value of hwLoopLineTestRABResPole is valid. Options: 1. valid(1) -the value of hwLoopLineTestRABResPole is valid 2. invalid(2) -the value of hwLoopLineTestRABResPole is invalid 3. notsupport(3) -the value of hwLoopLineTestRABResPole is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestCapAGFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.104
Indicates whether the value of hwLoopLineTestCapAG is valid. Options: 1. valid(1) -the value of hwLoopLineTestCapAG is valid 2. invalid(2) -the value of hwLoopLineTestCapAG is invalid 3. notsupport(3) -the value of hwLoopLineTestCapAG is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestCapBGFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.105
Indicates whether the value of hwLoopLineTestCapBG is valid. Options: 1. valid(1) -the value of hwLoopLineTestCapBG is valid 2. invalid(2) -the value of hwLoopLineTestCapBG is invalid 3. notsupport(3) -the value of hwLoopLineTestCapBG is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestCapABFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.106
Indicates whether the value of hwLoopLineTestCapAB is valid. Options: 1. valid(1) -the value of hwLoopLineTestCapAB is valid 2. invalid(2) -the value of hwLoopLineTestCapAB is invalid 3. notsupport(3) -the value of hwLoopLineTestCapAB is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestRbattipFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.107
Indicates whether the value of hwLoopLineTestRbattip is valid. Options: 1. valid(1) -the value of hwLoopLineTestRbattip is valid 2. invalid(2) -the value of hwLoopLineTestRbattip is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

hwLoopLineTestRbatringFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.108
Indicates whether the value of hwLoopLineTestRbatring is valid. Options: 1. valid(1) -the value of hwLoopLineTestRbatring is valid 2. invalid(2) -the value of hwLoopLineTestRbatring is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

hwLoopLineTestRringFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.109
Indicates whether the value of hwLoopLineTestRring is valid. Options: 1. valid(1) -the value of hwLoopLineTestRring is valid 2. invalid(2) -the value of hwLoopLineTestRring is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

hwLoopLineTestCsigFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.110
Indicates whether the value of hwLoopLineTestCsig is valid. Options: 1. valid(1) -the value of hwLoopLineTestCsig is valid 2. invalid(2) -the value of hwLoopLineTestCsig is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

hwLoopLineTestPPAResFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.111
Indicates whether the value of hwLoopLineTestPPARes is valid. Options: 1. valid(1) -the value of hwLoopLineTestPPARes is valid 2. invalid(2) -the value of hwLoopLineTestPPARes is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

hwLoopLineTestVzenerFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.112
Indicates whether the value of hwLoopLineTestVzener is valid. Options: 1. valid(1) -the value of hwLoopLineTestVzener is valid 2. invalid(2) -the value of hwLoopLineTestVzener is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

hwLoopLineTestRzenerFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.113
Indicates whether the value of hwLoopLineTestRzener is valid. Options: 1. valid(1) -the value of hwLoopLineTestRzener is valid 2. invalid(2) -the value of hwLoopLineTestRzener is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

hwLoopLineTestSNMPRab 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.114
Indicates the A to B resistance (insulation resistance). Unit: ohm
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestSNMPRabFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.115
Indicates whether the value of hwLoopLineTestSNMPRab is valid. Options: 1. valid(1) -the value of hwLoopLineTestSNMPRab is valid 2. invalid(2) -the value of hwLoopLineTestSNMPRab is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

hwLoopLineTestSNMPRba 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.116
Indicates the B to A resistance (insulation resistance). Unit: ohm
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestSNMPRbaFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.117
Indicates whether the value of hwLoopLineTestSNMPRba is valid. Options: 1. valid(1) -the value of hwLoopLineTestSNMPRba is valid 2. invalid(2) -the value of hwLoopLineTestSNMPRba is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

hwLoopLineTestPPAResultFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.118
Indicates whether the value of hwLoopLineTestPPA is valid. Options: 1. valid(1) -the value of hwLoopLineTestPPA is valid 2. invalid(2) -the value of hwLoopLineTestPPA is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

hwLoopLineTestUtgAcFreqFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.119
Indicates whether the value of hwLoopLineTestUtgAcFreq is valid. Options: 1. valid(1) -the value of hwLoopLineTestUtgAcFreq is valid 2. invalid(2) -the value of hwLoopLineTestUtgAcFreq is invalid 3. notsupport(3) -the value of hwLoopLineTestUtgAcFreq is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestUrgAcFreqFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.120
Indicates whether the value of hwLoopLineTestUrgAcFreq is valid. Options: 1. valid(1) -the value of hwLoopLineTestUrgAcFreq is valid 2. invalid(2) -the value of hwLoopLineTestUrgAcFreq is invalid 3. notsupport(3) -the value of hwLoopLineTestUrgAcFreq is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestUtrAcFreqFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.121
Indicates whether the value of hwLoopLineTestUtrAcFreq is valid. Options: 1. valid(1) -the value of hwLoopLineTestUtrAcFreq is valid 2. invalid(2) -the value of hwLoopLineTestUtrAcFreq is invalid 3. notsupport(3) -the value of hwLoopLineTestUtrAcFreq is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestItipAcFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.122
Indicates whether the value of hwLoopLineTestItipAc is valid. Options: 1. valid(1) -the value of hwLoopLineTestItipAc is valid 2. invalid(2) -the value of hwLoopLineTestItipAc is invalid 3. notsupport(3) -the value of hwLoopLineTestItipAc is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestIringAcFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.123
Indicates whether the value of hwLoopLineTestIringAc is valid. Options: 1. valid(1) -the value of hwLoopLineTestIringAc is valid 2. invalid(2) -the value of hwLoopLineTestIringAc is invalid 3. notsupport(3) -the value of hwLoopLineTestIringAc is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestItipDcFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.124
Indicates whether the value of hwLoopLineTestItipDc is valid. Options: 1. valid(1) -the value of hwLoopLineTestItipDc is valid 2. invalid(2) -the value of hwLoopLineTestItipDc is invalid 3. notsupport(3) -the value of hwLoopLineTestItipDc is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestIringDcFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.125
Indicates whether the value of hwLoopLineTestIringDc is valid. Options: 1. valid(1) -the value of hwLoopLineTestIringDc is valid 2. invalid(2) -the value of hwLoopLineTestIringDc is invalid 3. notsupport(3) -the value of hwLoopLineTestIringDc is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestGtgFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.126
Indicates whether the value of hwLoopLineTestGtg is valid. Options: 1. valid(1) -the value of hwLoopLineTestGtg is valid 2. invalid(2) -the value of hwLoopLineTestGtg is invalid 3. notsupport(3) -the value of hwLoopLineTestGtg is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestBtgFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.127
Indicates whether the value of hwLoopLineTestBtg is valid. Options: 1. valid(1) -the value of hwLoopLineTestBtg is valid 2. invalid(2) -the value of hwLoopLineTestBtg is invalid 3. notsupport(3) -the value of hwLoopLineTestBtg is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestGrgFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.128
Indicates whether the value of hwLoopLineTestGrg is valid. Options: 1. valid(1) -the value of hwLoopLineTestGrg is valid 2. invalid(2) -the value of hwLoopLineTestGrg is invalid 3. notsupport(3) -the value of hwLoopLineTestGrg is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestBrgFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.129
Indicates whether the value of hwLoopLineTestBrg is valid. Options: 1. valid(1) -the value of hwLoopLineTestBrg is valid 2. invalid(2) -the value of hwLoopLineTestBrg is invalid 3. notsupport(3) -the value of hwLoopLineTestBrg is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestGtrFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.130
Indicates whether the value of hwLoopLineTestGtr is valid. Options: 1. valid(1) -the value of hwLoopLineTestGtr is valid 2. invalid(2) -the value of hwLoopLineTestGtr is invalid 3. notsupport(3) -the value of hwLoopLineTestGtr is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestBtrFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.131
Indicates whether the value of hwLoopLineTestBtr is valid. Options: 1. valid(1) -the value of hwLoopLineTestBtr is valid 2. invalid(2) -the value of hwLoopLineTestBtr is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

hwLoopLineTestSIGNFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.132
Indicates whether the value of hwLoopLineTestSIGN is valid. Options: 1. valid(1) -the value of hwLoopLineTestSIGN is valid 2. invalid(2) -the value of hwLoopLineTestSIGN is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

hwLoopLineTestACFEMFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.133
Indicates whether the value of hwLoopLineTestACFEM is valid. Options: 1. valid(1) -the value of hwLoopLineTestACFEM is valid 2. invalid(2) -the value of hwLoopLineTestACFEM is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

hwLoopLineTestDCFEMFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.134
Indicates whether the value of hwLoopLineTestDCFEM is valid. Options: 1. valid(1) -the value of hwLoopLineTestDCFEM is valid 2. invalid(2) -the value of hwLoopLineTestDCFEM is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

hwLoopLineTestONHKFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.135
Indicates whether the value of hwLoopLineTestONHK is valid. Options: 1. valid(1) -the value of hwLoopLineTestONHK is valid 2. invalid(2) -the value of hwLoopLineTestONHK is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

hwLoopLineTestOPENFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.136
Indicates whether the value of hwLoopLineTestOPEN is valid. Options: 1. valid(1) -the value of hwLoopLineTestOPEN is valid 2. invalid(2) -the value of hwLoopLineTestOPEN is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

hwLoopLineTestSHORTFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.137
Indicates whether the value of hwLoopLineTestSHORT is valid. Options: 1. valid(1) -the value of hwLoopLineTestSHORT is valid 2. invalid(2) -the value of hwLoopLineTestSHORT is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

hwLoopLineTestROHFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.138
Indicates whether the value of hwLoopLineTestROH is valid. Options: 1. valid(1) -the value of hwLoopLineTestROH is valid 2. invalid(2) -the value of hwLoopLineTestROH is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

hwLoopLineTestUtgDcUpFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.139
Indicates whether the value of hwLoopLineTestUtgDcUp is valid. Options: 1. valid(1) -the value of hwLoopLineTestUtgDcUp is valid 2. invalid(2) -the value of hwLoopLineTestUtgDcUp is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

hwLoopLineTestUtgDcDownFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.140
Indicates whether the value of hwLoopLineTestUtgDcDown is valid. Options: 1. valid(1) -the value of hwLoopLineTestUtgDcDown is valid 2. invalid(2) -the value of hwLoopLineTestUtgDcDown is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

hwLoopLineTestUrgDcUpFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.141
Indicates whether the value of hwLoopLineTestUrgDcUp is valid. Options: 1. valid(1) -the value of hwLoopLineTestUrgDcUp is valid 2. invalid(2) -the value of hwLoopLineTestUrgDcUp is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

hwLoopLineTestUrgDcDownFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.142
Indicates whether the value of hwLoopLineTestUrgDcDown is valid. Options: 1. valid(1) -the value of hwLoopLineTestUrgDcDown is valid 2. invalid(2) -the value of hwLoopLineTestUrgDcDown is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

hwLoopLineTestUtrPosFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.143
Indicates whether the value of hwLoopLineTestUtrPos is valid. Options: 1. valid(1) -the value of hwLoopLineTestUtrPos is valid 2. invalid(2) -the value of hwLoopLineTestUtrPos is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

hwLoopLineTestUtrNegFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.144
Indicates whether the value of hwLoopLineTestUtrNeg is valid. Options: 1. valid(1) -the value of hwLoopLineTestUtrNeg is valid 2. invalid(2) -the value of hwLoopLineTestUtrNeg is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

hwLoopLineTestItgDcUpFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.145
Indicates whether the value of hwLoopLineTestItgDcUp is valid. Options: 1. valid(1) -the value of hwLoopLineTestItgDcUp is valid 2. invalid(2) -the value of hwLoopLineTestItgDcUp is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

hwLoopLineTestItgDcDownFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.146
Indicates whether the value of hwLoopLineTestItgDcDown is valid. Options: 1. valid(1) -the value of hwLoopLineTestItgDcDown is valid 2. invalid(2) -the value of hwLoopLineTestItgDcDown is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

hwLoopLineTestIrgDcUpFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.147
Indicates whether the value of hwLoopLineTestIrgDcUp is valid. Options: 1. valid(1) -the value of hwLoopLineTestIrgDcUp is valid 2. invalid(2) -the value of hwLoopLineTestIrgDcUp is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

hwLoopLineTestIrgDcDownFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.148
Indicates whether the value of hwLoopLineTestIrgDcDown is valid. Options: 1. valid(1) -the value of hwLoopLineTestIrgDcDown is valid 2. invalid(2) -the value of hwLoopLineTestIrgDcDown is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

hwLoopLineTestItrPosFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.149
Indicates whether the value of hwLoopLineTestItrPos is valid. Options: 1. valid(1) -the value of hwLoopLineTestItrPos is valid 2. invalid(2) -the value of hwLoopLineTestItrPos is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

hwLoopLineTestItrNegFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.150
Indicates whether the value of hwLoopLineTestItrNeg is valid. Options: 1. valid(1) -the value of hwLoopLineTestItrNeg is valid 2. invalid(2) -the value of hwLoopLineTestItrNeg is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

hwLoopLineTestRingerFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.151
Indicates whether the value of hwLoopLineTestRinger is valid. Options: 1. valid(1) -the value of hwLoopLineTestRinger is valid 2. invalid(2) -the value of hwLoopLineTestRinger is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

hwLoopLineTestLRFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.152
Indicates whether the value of hwLoopLineTestLR is valid. Options: 1. valid(1) -the value of hwLoopLineTestLR is valid 2. invalid(2) -the value of hwLoopLineTestLR is invalid 3. notsupport(3) -the value of hwLoopLineTestLR is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestDcCurrent 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.153
Indicates whether DcCurrent exists on the line under test. Options: 1. notest(1) -DcCurrent does not exist on the line under test 2. test(2) -DcCurrent exists on the line under test 3. invalid(-1) -invalid value Default: notest(1)
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notest(1), test(2), invalid(-1)  

hwLoopLineTestAcCurrent 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.154
Indicates whether AcCurrent exists on the line under test. Options: 1. notest(1) -AcCurrent does not exist on the line under test 2. test(2) -AcCurrent exists on the line under test 3. invalid(-1) -invalid value Default: notest(1)
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notest(1), test(2), invalid(-1)  

hwLoopLineTestConductance 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.155
Indicates whether conductance exists on the line under test. Options: 1. notest(1) -Conductance does not exist on the line under test 2. test(2) -Conductance exists on the line under test 3. invalid(-1) -invalid value Default: notest(1)
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notest(1), test(2), invalid(-1)  

hwLoopLineTestSusceptance 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.156
Indicates whether susceptance exists on the line under test. Options: 1. notest(1) -Susceptance does not exist on the line under test 2. test(2) -Susceptance exists on the line under test 3. invalid(-1) -invalid value Default: notest(1)
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notest(1), test(2), invalid(-1)  

hwLoopLineTestAcfrequencyA 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.157
Indicates status of Acfrequency in line A. Options: 1. sixteenDotSix(1) -line A has ACFrequency 16.6 2. twentyFive(2) -line A has ACFrequency 25 3. fifty(3) -line A has ACFrequency 50 4. sixty(4) -line A has ACFrequency 60 5. unknown(5) -line A has unknown ACFrequency 6. invalid(-1) -invalid value Unit: Hz
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER sixteenDotSix(1), twentyFive(2), fifty(3), sixty(4), unknown(5), invalid(-1)  

hwLoopLineTestAcfrequencyB 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.158
Indicates status of Acfrequency in line A. Options: 1. sixteenDotSix(1) -line A has ACFrequency 16.6 2. twentyFive(2) -line A has ACFrequency 25 3. fifty(3) -line A has ACFrequency 50 4. sixty(4) -line A has ACFrequency 60 5. unknown(5) -line A has unknown ACFrequency 6. invalid(-1) -invalid value Unit: Hz
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER sixteenDotSix(1), twentyFive(2), fifty(3), sixty(4), unknown(5), invalid(-1)  

hwLoopLineTestCapABH 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.159
Indicates the A->B capacitance. Unit: nF
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestCapABHFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.160
Indicates whether the value of hwLoopLineTestCapABH is valid. Options: 1. valid(1) -the value of hwLoopLineTestCapABH is valid 2. invalid(2) -the value of hwLoopLineTestCapABH is invalid 3. notsupport(3) -the value of hwLoopLineTestCapABH is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestGtrH 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.161
Indicates the A->B conductance. Unit: nS
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestGtrHFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.162
Indicates whether the value of hwLoopLineTestGtrH is valid. Options: 1. valid(1) -the value of hwLoopLineTestGtrH is valid 2. invalid(2) -the value of hwLoopLineTestGtrH is invalid 3. notsupport(3) -the value of hwLoopLineTestGtrH is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestBtrH 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.163
Indicates the A->B susceptance. Unit: nS
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestBtrHFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.164
Indicates whether the value of hwLoopLineTestBtrH is valid. Options: 1. valid(1) -the value of hwLoopLineTestBtrH is valid 2. invalid(2) -the value of hwLoopLineTestBtrH is invalid 3. notsupport(3) -the value of hwLoopLineTestBtrH is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestABDcCurrent 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.165
Indicates the A->B Dc current. Unit: uA
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestABDcCurrentFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.166
Indicates whether the value of hwLoopLineTestABDcCurrent is valid. Options: 1. valid(1) -the value of hwLoopLineTestABDcCurrent is valid 2. invalid(2) -the value of hwLoopLineTestABDcCurrent is invalid 3. notsupport(3) -the value of hwLoopLineTestABDcCurrent is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestBADcCurrent 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.167
Indicates the B->A Dc current. Unit: uA
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestBADcCurrentFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.168
Indicates whether the value of hwLoopLineTestBADcCurrent is valid. Options: 1. valid(1) -the value of hwLoopLineTestBADcCurrent is valid 2. invalid(2) -the value of hwLoopLineTestBADcCurrent is invalid 3. notsupport(3) -the value of hwLoopLineTestBADcCurrent is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestABAcCurrent 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.169
Indicates the A->B Ac current. Unit: uArms
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestABAcCurrentFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.170
Indicates whether the value of hwLoopLineTestABAcCurrent is valid. Options: 1. valid(1) -the value of hwLoopLineTestABAcCurrent is valid 2. invalid(2) -the value of hwLoopLineTestABAcCurrent is invalid 3. notsupport(3) -the value of hwLoopLineTestABAcCurrent is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestBAAcCurrent 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.171
Indicates the B->A Ac current. Unit: uArms
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestBAAcCurrentFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.172
Indicates whether the value of hwLoopLineTestBAAcCurrent is valid. Options: 1. valid(1) -the value of hwLoopLineTestBAAcCurrent is valid 2. invalid(2) -the value of hwLoopLineTestBAAcCurrent is invalid 3. notsupport(3) -the value of hwLoopLineTestBAAcCurrent is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestCSfrequencyForTest 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.173
Indicates the frequency for test capacitance and conductance. Unit: Hz
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestCSfrequencyForTestFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.174
Indicates whether the value of hwLoopLineTestCSfrequencyForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestCSfrequencyForTest is valid 2. invalid(2) -the value of hwLoopLineTestCSfrequencyForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestCSfrequencyForTest is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestImpedanceForTest 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.175
Indicates the resistance inputed in test abnormal voltage. Unit:
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestImpedanceForTestFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.176
Indicates whether the value of hwLoopLineTestImpedanceForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestImpedanceForTest is valid 2. invalid(2) -the value of hwLoopLineTestImpedanceForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestImpedanceForTest is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestMaxVForSignature 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.177
Indicates the maximum voltage for signature. Unit: mV
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestMaxVForSignatureFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.178
Indicates whether the value of hwLoopLineTestMaxVForSignature is valid. Options: 1. valid(1) -the value of hwLoopLineTestMaxVForSignature is valid 2. invalid(2) -the value of hwLoopLineTestMaxVForSignature is invalid 3. notsupport(3) -the value of hwLoopLineTestMaxVForSignature is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestAGMaxVForTest 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.179
Indicates the A->ground max voltage in testing. Unit: mV
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestAGMaxVForTestFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.180
Indicates whether the value of hwLoopLineTestAGMaxVForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestAGMaxVForTest is valid 2. invalid(2) -the value of hwLoopLineTestAGMaxVForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestAGMaxVForTest is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestAGMinVForTest 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.181
Indicates the A->ground min voltage in testing. Unit: mV
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestAGMinVForTestFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.182
Indicates whether the value of hwLoopLineTestAGMinVForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestAGMinVForTest is valid 2. invalid(2) -the value of hwLoopLineTestAGMinVForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestAGMinVForTest is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestBGMaxVForTest 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.183
Indicates the B->ground max voltage in testing. Unit: mV
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestBGMaxVForTestFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.184
Indicates whether the value of hwLoopLineTestBGMaxVForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestBGMaxVForTest is valid 2. invalid(2) -the value of hwLoopLineTestBGMaxVForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestBGMaxVForTest is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestBGMinVForTest 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.185
Indicates the B->ground min voltage in testing. Unit: mV
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestBGMinVForTestFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.186
Indicates whether the value of hwLoopLineTestBGMinVForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestBGMinVForTest is valid 2. invalid(2) -the value of hwLoopLineTestBGMinVForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestBGMinVForTest is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestABMaxVForTest 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.187
Indicates the A->B max voltage in testing. Unit: mV
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestABMaxVForTestFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.188
Indicates whether the value of hwLoopLineTestABMaxVForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestABMaxVForTest is valid 2. invalid(2) -the value of hwLoopLineTestABMaxVForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestABMaxVForTest is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestABMinVForTest 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.189
Indicates the A->ground min voltage in testing. Unit: mV
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestABMinVForTestFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.190
Indicates whether the value of hwLoopLineTestABMinVForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestABMinVForTest is valid 2. invalid(2) -the value of hwLoopLineTestABMinVForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestABMinVForTest is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestAGMaxCForTest 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.191
Indicates the A->ground max current. Unit: uA
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestAGMaxCForTestFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.192
Indicates whether the value of hwLoopLineTestAGMaxCForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestAGMaxCForTest is valid 2. invalid(2) -the value of hwLoopLineTestAGMaxCForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestAGMaxCForTest is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestAGMinCForTest 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.193
Indicates the A->ground min current. Unit: uA
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestAGMinCForTestFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.194
Indicates whether the value of hwLoopLineTestAGMinCForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestAGMinCForTest is valid 2. invalid(2) -the value of hwLoopLineTestAGMinCForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestAGMinCForTest is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestBGMaxCForTest 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.195
Indicates the B->ground max current. Unit: uA
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestBGMaxCForTestFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.196
Indicates whether the value of hwLoopLineTestBGMaxCForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestBGMaxCForTest is valid 2. invalid(2) -the value of hwLoopLineTestBGMaxCForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestBGMaxCForTest is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestBGMinCForTest 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.197
Indicates the B->ground min current. Unit: uA
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestBGMinCForTestFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.198
Indicates whether the value of hwLoopLineTestBGMinCForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestBGMinCForTest is valid 2. invalid(2) -the value of hwLoopLineTestBGMinCForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestBGMinCForTest is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestABMaxCForTest 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.199
Indicates the A->B max current Unit: uA
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestABMaxCForTestFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.200
Indicates whether the value of hwLoopLineTestABMaxCForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestABMaxCForTest is valid 2. invalid(2) -the value of hwLoopLineTestABMaxCForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestABMaxCForTest is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestABMaxNegCForTest 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.201
Indicates the A->ground min current Unit: uA
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestABMaxNegCForTestFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.202
Indicates whether the value of hwLoopLineTestABMaxNegCForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestABMaxNegCForTest is valid 2. invalid(2) -the value of hwLoopLineTestABMaxNegCForTest is invalid 3. notsupport(3) -the value of hwLoopLineTestABMaxNegCForTest is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestLineALength 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.203
Indicates length of line A Unit: m
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestLineBLength 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.204
Indicates length of line B Unit: m
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestTermimalConcusion 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.205
Indicates Termimal Concusion Options: 1. noPhone(1) -the TermimalConcusion is not connect Phone 2. offHook(2) -the TermimalConcusion is connect phone and offhook 3. eTSIxDSLsignature(3) -the TermimalConcusion is ETSI XDSL Signature 4. abMixed(4) -the TermimalConcusion is ab line short 5. rcNetWork(5) -the TermimalConcusion is rcNetWork 6. elecRing(6) -the TermimalConcusion is elecRing 7. other(7) -the TermimalConcusion is other unknown terminal 8. abMixInMDF(8) -the TermimalConcusion is abMixInMDF 9. abMixOutMDF(9) -the TermimalConcusion is abMixOutMDF 10. invalid(-1) -the TermimalConcusion is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noPhone(1), offHook(2), eTSIxDSLsignature(3), abMixed(4), rcNetWork(5), elecRing(6), other(7), abMixInMDF(8), abMixOutMDF(9), invalid(-1)  

hwLoopLineTestMoreDataFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.206
Indicates is there more data Options: 1. more(1) -Indicates there is more data needs report,but needs a SNMP-GET oper. to get other data. 2. invalid(-1) -Indicates the value is invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER more(1), invalid(-1)  

hwLoopLineTestCtrLV 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.207
Aggregate tip-ring capacitance: CtrLV = Cco + Ctr + Cring, measured by means of low voltage ramps, such that it does NOT include the capacitance Csig whenever the ETSI Signature terminates the subscriber loop. Unit: nF
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestCtrLVFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.208
Indicates whether the value of hwLoopLineTestCtrLV is valid. Options: 1. valid(1) -the value of hwLoopLineTestCtrLV is valid 2. invalid(2) -the value of hwLoopLineTestCtrLV is invalid 3. notsupport(3) -the value of hwLoopLineTestCtrLV is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestCtrHV 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.209
Aggregate tip-ring capacitance: CtrHV = Cco + Ctr + Cring + Csig, measured by means of high voltage ramps. It includes the capacitance Csig of an ETSI Signature whenever connected to the tip and ring wires. Unit: nF
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestCtrHVFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.210
Indicates whether the value of hwLoopLineTestCtrHV is valid. Options: 1. valid(1) -the value of hwLoopLineTestCtrHV is valid 2. invalid(2) -the value of hwLoopLineTestCtrHV is invalid 3. notsupport(3) -the value of hwLoopLineTestCtrHV is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestCtrAc 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.211
Aggregate tip-ring capacitance: CtrAc = Cco + Ctr + Cring, measured by means of a low amplitude AC signal (either 25 Hz or 275 Hz). It does NOT include Csig. Unit: nF
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestCtrAcFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.212
Indicates whether the value of hwLoopLineTestCtrAc is valid. Options: 1. valid(1) -the value of hwLoopLineTestCtrAc is valid 2. invalid(2) -the value of hwLoopLineTestCtrAc is invalid 3. notsupport(3) -the value of hwLoopLineTestCtrAc is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestRtgSer 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.213
Resistance in series with Ctg, measured at the selected AC frequency (either 25 Hz or 275 Hz) by means of a low amplitude AC signal. Unit: ohm
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestRtgSerFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.214
Indicates whether the value of hwLoopLineTestRtgSer is valid. Options: 1. valid(1) -the value of hwLoopLineTestRtgSer is valid 2. invalid(2) -the value of hwLoopLineTestRtgSer is invalid 3. notsupport(3) -the value of hwLoopLineTestRtgSer is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestRrgSer 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.215
Resistance in series with Crg, measured at the selected AC frequency (either 25 Hz or 275 Hz) by means of a low amplitude AC signal. Unit: ohm
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestRrgSerFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.216
Indicates whether the value of hwLoopLineTestRrgSer is valid. Options: 1. valid(1) -the value of hwLoopLineTestRrgSer is valid 2. invalid(2) -the value of hwLoopLineTestRrgSer is invalid 3. notsupport(3) -the value of hwLoopLineTestRrgSer is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestRtrSer 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.217
Resistance in series with Ctring, measured at the selected AC frequency (either 25 Hz or 275 Hz) by means of a low amplitude AC signal. Unit: ohm
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestRtrSerFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.218
Indicates whether the value of hwLoopLineTestRtrSer is valid. Options: 1. valid(1) -the value of hwLoopLineTestRtrSer is valid 2. invalid(2) -the value of hwLoopLineTestRtrSer is invalid 3. notsupport(3) -the value of hwLoopLineTestRtrSer is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestUtgAcAdmit 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.219
Amplitude of the AC signal (either 25 Hz or 275 Hz) applied to the tipground admittance Ytg = Gtg + i * Btg. Unit: V
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestUtgAcAdmitFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.220
Indicates whether the value of hwLoopLineTestUtgAcAdmit is valid. Options: 1. valid(1) -the value of hwLoopLineTestUtgAcAdmit is valid 2. invalid(2) -the value of hwLoopLineTestUtgAcAdmit is invalid 3. notsupport(3) -the value of hwLoopLineTestUtgAcAdmit is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestUrgAcAdmit 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.221
Amplitude of the AC signal (either 25 Hz or 275 Hz) applied to the ringground admittance Yrg = Grg + i * Brg. Unit: V
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestUrgAcAdmitFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.222
Indicates whether the value of hwLoopLineTestUrgAcAdmit is valid. Options: 1. valid(1) -the value of hwLoopLineTestUrgAcAdmit is valid 2. invalid(2) -the value of hwLoopLineTestUrgAcAdmit is invalid 3. notsupport(3) -the value of hwLoopLineTestUrgAcAdmit is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestUtrAcAdmit 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.223
Amplitude of the AC signal (either 25 Hz or 275 Hz) applied to the tip-ring admittance Ytr = Gtr + i * Btr. Unit: V
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestUtrAcAdmitFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.224
Indicates whether the value of hwLoopLineTestUtrAcAdmit is valid. Options: 1. valid(1) -the value of hwLoopLineTestUtrAcAdmit is valid 2. invalid(2) -the value of hwLoopLineTestUtrAcAdmit is invalid 3. notsupport(3) -the value of hwLoopLineTestUtrAcAdmit is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwLoopLineTestCapterminal 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.225
A capacitive termination of the access line shall be identified by the capacitance measurement and the associated evaluation. The following average value for the capacitance Cabk of the measured cable can be assumed: Cabk = 0.083(Cae + Cbe). If the measured capacitance is Cab > Cabk + 50 nF for ADSL&VDSL, or Cab > Cabk + 100 nF for SHDSL, respectively, It can be assumed that a terminal device with a significant self-capacitance is connected to the line. The cable-factor 0.083 is determined by hwLoopLineTestSysConfigCableFactor. Options: 1. noexist(1) -Significant terminal device capacitance is not detected 2. exist(2) -Significant terminal device capacitance is detected
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noexist(1), exist(2)  

hwLoopLineTestCapterminalFlag 1.3.6.1.4.1.2011.6.21.1.1.1.2.1.226
Indicates whether the value of hwLoopLineTestCapterminal is valid. Options: 1. valid(1) -the value of hwLoopLineTestCapterminal is valid 2. invalid(2) -the value of hwLoopLineTestCapterminal is invalid 3. notsupport(3) -the value of hwLoopLineTestCapterminal is not support
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2), notsupport(3)  

hwMeterTestOprTable 1.3.6.1.4.1.2011.6.21.1.1.1.3
Operation table of the meter test. It implements the meter test function in the system. The test board provides the interface connected to the external test meter such as a multimeter through the meter test function. The index of this table is ifIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwMeterTestOprEntry

hwMeterTestOprEntry 1.3.6.1.4.1.2011.6.21.1.1.1.3.1
Operation table of the meter test. It implements the meter test function in the system. The test board provides the interface connected to the external test meter such as a multimeter through the meter test function. The index of this entry is ifIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwMeterTestOprEntry  

hwMeterTestOprType 1.3.6.1.4.1.2011.6.21.1.1.1.3.1.1
Operation type. Options: 1. stop(1) -operation type is stop 2. start(2) -operation type is start
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER stop(1), start(2)  

hwMeterTestItem 1.3.6.1.4.1.2011.6.21.1.1.1.3.1.2
Test items. Options: 1. inline(1) -in test 2. outline(2) -out test
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER inline(1), outline(2)  

hwMeterTestStatus 1.3.6.1.4.1.2011.6.21.1.1.1.3.1.3
Test status. Options: 1. success(1) -no test on busy 2. fail(2) -remedy test on busy 3. portbusy(3) -forced test on busy 4. outoftime(4) -test out of time 5. testingAbnormal(5) -test abnormal 6. broadbandtesting(6) -broadband testing 7. capturefail(7) -capture fail 8. notratb(8) -relay transfer board not exist
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER success(1), fail(2), portbusy(3), outoftime(4), testingAbnormal(5), broadbandtesting(6), capturefail(7), notratb(8)  

hwMeterTestBusyFlag 1.3.6.1.4.1.2011.6.21.1.1.1.3.1.4
Meter test busy flag. Options: 1. busyNoTest(1) -no test on busy 2. busyTest(2) -test on busy 3. busystrenTest(3) -forced test on busy
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER busyNoTest(1), busyTest(2), busystrenTest(3)  

hwTestBoardDiagnoseTestOprTable 1.3.6.1.4.1.2011.6.21.1.1.1.4
Operation table of the self-test on the test board. It implements the self-test on the test board in the system. The self-test checks whether the test board can work in the normal state. The index of this table is ifIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwTestBoardDiagnoseTestOprEntry

hwTestBoardDiagnoseTestOprEntry 1.3.6.1.4.1.2011.6.21.1.1.1.4.1
Operation table of the self-test on the test board. It implements the self-test on the test board in the system. The self-test checks whether the test board can work in the normal state. The index of this entry is ifIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwTestBoardDiagnoseTestOprEntry  

hwTestBoardDiagnoseTestOprType 1.3.6.1.4.1.2011.6.21.1.1.1.4.1.1
Operation type. Options: 1. start(2) -operation type is start
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER start(2)  

hwTestBoardDiagnoseTestResult 1.3.6.1.4.1.2011.6.21.1.1.1.4.1.2
Self-diagnosis result. Options: 1. selfTestOver(1) -self-diagnosis successful 2. selfTestFail(2) -self-diagnosis failure 3. testingAbnormal(3) -test abnormal
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER selfTestOver(1), selfTestFail(2), testingAbnormal(3)  

hwTestBoardDiagnoseTestRAM 1.3.6.1.4.1.2011.6.21.1.1.1.4.1.3
System RAMRAM. Options: 1. normal(1) -normal 2. abnormal(2) -abnormal
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), abnormal(2)  

hwTestBoardDiagnoseTestVoltage 1.3.6.1.4.1.2011.6.21.1.1.1.4.1.4
Voltage. Options: 1. normal(1) -normal 2. abnormal(2) -abnormal
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), abnormal(2)  

hwTestBoardDiagnoseTestResistance 1.3.6.1.4.1.2011.6.21.1.1.1.4.1.5
Resistance. Options: 1. normal(1) -normal 2. abnormal(2) -abnormal
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), abnormal(2)  

hwTestBoardDiagnoseTestSignal 1.3.6.1.4.1.2011.6.21.1.1.1.4.1.6
Signal circuit. Options: 1. normal(1) -normal 2. abnormal(2) -abnormal
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), abnormal(2)  

hwTestBoardDiagnoseTestDTMF 1.3.6.1.4.1.2011.6.21.1.1.1.4.1.7
DTMF. Options: 1. normal(1) -normal 2. abnormal(2) -abnormal
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), abnormal(2)  

hwTestBoardDiagnoseTestRing 1.3.6.1.4.1.2011.6.21.1.1.1.4.1.8
Ringing. Options: 1. normal(1) -normal 2. abnormal(2) -abnormal
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), abnormal(2)  

hwTestBoardDiagnoseTestOnOffHook 1.3.6.1.4.1.2011.6.21.1.1.1.4.1.9
On/off hook. Options: 1. normal(1) -normal 2. abnormal(2) -abnormal
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), abnormal(2)  

hwTestBoardDiagnoseTestPole 1.3.6.1.4.1.2011.6.21.1.1.1.4.1.10
Polarity reversal. Options: 1. normal(1) -normal 2. abnormal(2) -abnormal
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), abnormal(2)  

hwTestBoardDiagnoseTestISDNU 1.3.6.1.4.1.2011.6.21.1.1.1.4.1.11
ISDN U port. Options: 1. normal(1) -normal 2. abnormal(2) -abnormal
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), abnormal(2)  

hwTestBoardDiagnoseTestBitErrCode 1.3.6.1.4.1.2011.6.21.1.1.1.4.1.12
Error code test. Options: 1. normal(1) -normal 2. abnormal(2) -abnormal
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), abnormal(2)  

hwTestBoardDiagnoseTestCapacitance 1.3.6.1.4.1.2011.6.21.1.1.1.4.1.13
Capacitance. Options: 1. normal(1) -normal 2. abnormal(2) -abnormal
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), abnormal(2)  

hwTestBoardStatusQueryOprTable 1.3.6.1.4.1.2011.6.21.1.1.1.5
Operation table for querying the status of the test board. It implements the function of querying the status of the test board in the system. You can query the current status of the test board through this function. The index of this table is ifIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwTestBoardStatusQueryOprEntry

hwTestBoardStatusQueryOprEntry 1.3.6.1.4.1.2011.6.21.1.1.1.5.1
Operation table for querying the status of the test board. It implements the function of querying the status of the test board in the system. You can query the current status of the test board through this function. The index of this entry is ifIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwTestBoardStatusQueryOprEntry  

hwTestBoardStatusQueryOprType 1.3.6.1.4.1.2011.6.21.1.1.1.5.1.1
Operation type. Options: 1. beginQuery(2) -start
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER beginQuery(2)  

hwTestBoardStatusQueryResult 1.3.6.1.4.1.2011.6.21.1.1.1.5.1.2
Query status. Options: 1. querySuccess(1) -query status successful 2. queryFail(2) -query status failure
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER querySuccess(1), queryFail(2)  

hwTestBoardStatusQueryVersion 1.3.6.1.4.1.2011.6.21.1.1.1.5.1.3
Version.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwTestBoardStatusQueryTestItem 1.3.6.1.4.1.2011.6.21.1.1.1.5.1.4
Test item. Options: 1. testIdle(1) -idle 2. pstnUserInLineTest(2) -pstn inline test 3. userLineTest(3) -loop line test 4. phoneTest(4) -telephone test 5. manTestOutLine(5) -manual test outline 6. manTestInnerLine(6) -manual test inline 7. halfAutoUserCircuit(7) -half auto tss user circuit -meter interface 8. halfAutoTssPhoneCircuit(8) -half auto tss telephone circuit -meter interface 9. tssSelfTest(9) -Tss self test 10. testInnerBus(10) -test inline bus test 11. testOuterBus(11) -test outline bus test 12. digUserOutLineTest(12) -isdn outline test 13. digUserInnerLineTest(13) -isdn inline test 14. switchToStandIsdnTerminal(14) -switch to standard isdn terminal 15. switchToIsdnSpecialcode(15) -switch to isdn special service telephone number 16. testBoarDfault(16) -test board fault 17. pstnRemoteCallTest(17) -pstn user remote call test 18. indialtest(18) -in-dial test 19. coEmulate(33) -CO simulation test 20. cqtTest(34) -CQT test 21. cqtFRTest(35) -CQT Frequency Response Measurement 22. cqtTDRTest(36) -CQT Time Domain Reflectometry Measurement 23. cqtDMTTest(37) -CQT Data Rate Prediction Measurement 24. cqtNSETest(38) -CQT Noise Measurement 25. cqtLBTest(39) -CQT Longitudinal Balance Measurement 26. cqtLCTest(40) -CQT Load Coil Detection 27. internalcaptureTestedPort(61) -Capture tested port loopline 28. externalcaptureTestedPort(62) -Capture tested port inline 29. monitorTest(63) -monitor test 30. seltTest(64) -selt test 31. sendtoneTest(65) -tone send test 32. checktoneTest(66) -tone check test 33. autocalltest(67) -auto call test 34. anothermainboardistesting(241) -another main board is testing
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER testIdle(1), pstnUserInLineTest(2), userLineTest(3), phoneTest(4), manTestOutLine(5), manTestInnerLine(6), halfAutoUserCircuit(7), halfAutoTssPhoneCircuit(8), tssSelfTest(9), testInnerBus(10), testOuterBus(11), digUserOutLineTest(12), digUserInnerLineTest(13), switchToStandIsdnTerminal(14), switchToIsdnSpecialcode(15), testBoarDfault(16), pstnRemoteCallTest(17), indialtest(18), coEmulate(33), cqtTest(34), cqtFRTest(35), cqtTDRTest(36), cqtDMTTest(37), cqtNSETest(38), cqtLBTest(39), cqtLCTest(40), internalcaptureTestedPort(61), externalcaptureTestedPort(62), monitorTest(63), seltTest(64), sendtoneTest(65), checktoneTest(66), autocalltest(67), anothermainboardistesting(241)  

hwTestBoardStatusTestedBoardIfIndex 1.3.6.1.4.1.2011.6.21.1.1.1.5.1.5
Index of the tested port.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwSearchingToneOprTable 1.3.6.1.4.1.2011.6.21.1.1.1.6
This table is used for enabling the searching tone test by setting the searching tone test voltage level, test frequency, and test duration. The searching tone test is to locate a specific line from various lines by transmitting pulse tones to lines. This test helps carriers locate faults and provision services. The index of this table is ifindex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwSearchingToneOprEntry

hwSearchingToneOprEntry 1.3.6.1.4.1.2011.6.21.1.1.1.6.1
This table is used for enabling the searching tone test by setting the searching tone test voltage level, test frequency, and test duration. The searching tone test is to locate a specific line from various lines by transmitting pulse tones to lines. This test helps carriers locate faults and provision services. The index of this entry is ifindex.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwSearchingToneOprEntry  

hwSearchingToneOprType 1.3.6.1.4.1.2011.6.21.1.1.1.6.1.1
Searching tone test-operation type. Options: 1. stop(1) -stop a searching tone test 2. start(2) -start a searching tone test 3. invalid(-1) -invalid value
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER stop(1), start(2), invalid(-1)  

hwSearchingToneLevel 1.3.6.1.4.1.2011.6.21.1.1.1.6.1.2
Indicates the test voltage level of a searching tone test. Options: 1. -1 -Invalid value 2. 80..500 -(XDSL Range: 80-126 MXU voice Range: 80-500) Default: 120 -(XDSL Default: 120 MXU voice default:295) Unit: mV
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1 | 80..500  

hwSearchingToneFrequency 1.3.6.1.4.1.2011.6.21.1.1.1.6.1.3
Indicates the test frequency of a searching tone test. Default: 800 Unit: Hz
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1 | 300..3400  

hwSearchingToneDurationTime 1.3.6.1.4.1.2011.6.21.1.1.1.6.1.4
Indicates the test duration of a searching tone test. Default: 9000 Unit: 0.1s
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1 | 1..54000  

hwSearchingToneRemainingTime 1.3.6.1.4.1.2011.6.21.1.1.1.6.1.5
Indicates the test remaining time of a searching tone test. Unit: 0.1s
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwSearchingToneBusyProcFlag 1.3.6.1.4.1.2011.6.21.1.1.1.6.1.6
Searching tone test-busy flag. Options: 1. cancel(1) -when port is busy do not start a searching tone test 2. force(2) -when port is busy force to start a searching tone test 3. invalid(-1) -invalid value
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER cancel(1), force(2), invalid(-1)  

hwLoopLineTestCalibrationTable 1.3.6.1.4.1.2011.6.21.1.1.1.7
This table provides the test calibration data of a line. Before delivery, each port is performed with a test in which no user is connected to the port and the test result is saved as standard data. The standard data is used for calibrating the test result of tests in the actual environment. The index of this table is ifindex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwLoopLineTestCalibrationEntry

hwLoopLineTestCalibrationEntry 1.3.6.1.4.1.2011.6.21.1.1.1.7.1
This table provides the test calibration data of a line. Before delivery, each port is performed with a test in which no user is connected to the port and the test result is saved as standard data. The standard data is used for calibrating the test result of tests in the actual environment. The index of this entry is ifindex.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwLoopLineTestCalibrationEntry  

hwLoopLineTestAGCalibration 1.3.6.1.4.1.2011.6.21.1.1.1.7.1.1
Indicates the test calibration data of A->Ground capacitance. Unit: nF
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestBGCalibration 1.3.6.1.4.1.2011.6.21.1.1.1.7.1.2
Indicates the test calibration data of B->Ground capacitance. Unit: nF
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwLoopLineTestABCalibration 1.3.6.1.4.1.2011.6.21.1.1.1.7.1.3
Indicates the test calibration data of A->B capacitance. Unit: nF
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwTestCommonTraps 1.3.6.1.4.1.2011.6.21.1.2
OBJECT IDENTIFIER    

hwTestCommonTrapVbOids 1.3.6.1.4.1.2011.6.21.1.2.1
OBJECT IDENTIFIER    

hwTestCommonVbOidsReason 1.3.6.1.4.1.2011.6.21.1.2.1.2
OBJECT IDENTIFIER    

hwTestClearedReason 1.3.6.1.4.1.2011.6.21.1.2.1.2.1
Definition of the test-canceling reasons. Options: 1. testBoardFail(1) -the test-canceling reason is testBoardFail 2. testedBoardFail(2) -the test-canceling reason is testedBoardFail 3. userCmd(3) -the test-canceling reason is userCmd 4. switchOver(4) -the test-canceling reason is switchOver 5. anotherMainBoardIsTesting(5) -the test-canceling reason is anotherMainBoardIsTesting 6. unknowError(255) -the test-canceling reason is unknowError
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER testBoardFail(1), testedBoardFail(2), userCmd(3), switchOver(4), anotherMainBoardIsTesting(5), unknowError(255)  

hwTestRingSrcAlarmReason 1.3.6.1.4.1.2011.6.21.1.2.1.2.2
Definition of the ringing source alarms. Options: 1. testRingSrcFail(1) -the ringing source alarm is testRingSrcFail 2. testRingSrcRestore(2) -the ringing source alarm is testRingSrcRestore
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER testRingSrcFail(1), testRingSrcRestore(2)  

hwTestCommonRequestID 1.3.6.1.4.1.2011.6.21.1.2.1.3
NMS request ID.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

hwTestCommonAlarmTraps 1.3.6.1.4.1.2011.6.21.1.2.2
OBJECT IDENTIFIER    

hwTestCommonAlarmTrapsOIDs 1.3.6.1.4.1.2011.6.21.1.2.2.0
OBJECT IDENTIFIER    

hwTestRingSrcFailTrap 1.3.6.1.4.1.2011.6.21.1.2.2.0.1
The btss ring source failed trap: 1: hwTestBoardIfIndex; 2: hwTestRingSrcAlarmReason (1: the ring source of BTSS doesn't work) Troubleshooting suggestions: (1) Check the BTSS board; (2) Reset the BTSS board; (3) Replace the BTSS board. This trap will send when the btss ring source failed.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwTestRingSrcRestoreTrap 1.3.6.1.4.1.2011.6.21.1.2.2.0.2
Test ringing source restore trap: 1: hwTestBoardIfIndex; 2: hwTestRingSrcAlarmReason (1: the ring source of BTSS is normal) The advice: none. This trap will send when test ringing source restore.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwTestAutoClearedTrap 1.3.6.1.4.1.2011.6.21.1.2.2.0.3
Trap of test automatically cancelled: 1: hwTestBoardIfIndex; 2: hwTestBoardStatusTestedBoardIfIndex; 3: hwTestClearedReason. This trap will send when the test automatically cancelled.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwTestCommonGeneralTraps 1.3.6.1.4.1.2011.6.21.1.2.3
OBJECT IDENTIFIER    

hwTestCommonGeneralTrapsOIDs 1.3.6.1.4.1.2011.6.21.1.2.3.0
OBJECT IDENTIFIER    

hwLoopLineTestTrap 1.3.6.1.4.1.2011.6.21.1.2.3.0.1
This trap will be sent when a loop-line test finished successfully. The trap shows the result of the loop-line test. 1. hwLoopLineTestRequestID, 2. hwLoopLineTestStatus, 3. hwLoopLineTestConclusion, 4. hwLoopLineTestACAG, 5. hwLoopLineTestACBG, 6. hwLoopLineTestACAB, 7. hwLoopLineTestDCAG, 8. hwLoopLineTestDCBG, 9. hwLoopLineTestDCAB, 10. hwLoopLineTestRAG, 11. hwLoopLineTestRBG, 12. hwLoopLineTestRAB, 13. hwLoopLineTestCapAG, 14. hwLoopLineTestCapBG, 15. hwLoopLineTestCapAB, 16. hwLoopLineTestLR, 17. hwLoopLineTestRABResPole, 18. hwLoopLineTestMSocket, 19. hwLoopLineTestPPAResult, 19. hwLoopLineTestIfIndex, 20. hwLoopLineTestMoreDataFlag
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwMeterTestTrap 1.3.6.1.4.1.2011.6.21.1.2.3.0.2
Meter test result trap: 1: hwMeterTestStatus. This trap will send when meter test result return.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwTestBoardDiagnoseTestTrap 1.3.6.1.4.1.2011.6.21.1.2.3.0.3
Test board self-test result trap: 1: hwTestBoardDiagnoseTestResult; 2: hwTestBoardDiagnoseTestRAM; 3: hwTestBoardDiagnoseTestVoltage; 4: hwTestBoardDiagnoseTestResistance; 5: hwTestBoardDiagnoseTestSignal; 6: hwTestBoardDiagnoseTestDTMF; 7: hwTestBoardDiagnoseTestRing; 8: hwTestBoardDiagnoseTestOnOffHook; 9: hwTestBoardDiagnoseTestPole; 10: hwTestBoardDiagnoseTestISDNU; 11: hwTestBoardDiagnoseTestBitErrCode; 12: hwTestBoardDiagnoseTestCapacitance. This trap will send when the test board self-test result return.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwTestBoardStatusQueryTrap 1.3.6.1.4.1.2011.6.21.1.2.3.0.4
Test board status query result trap: 1: hwTestBoardStatusQueryResult; 2: hwTestBoardStatusQueryVersion; 3: hwTestBoardStatusQueryTestItem; 4: hwTestBoardStatusTestedBoardIfIndex. This trap will send when the test board status query result return.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwTestOntPotsTestResultTrap 1.3.6.1.4.1.2011.6.21.1.2.3.0.5
This trap indicates that a POTS port line test finished successfully, and shows the result of the line test. This trap will send when a POTS port line test finished successfully.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwTestCommonMeltTestResultTrap 1.3.6.1.4.1.2011.6.21.1.2.3.0.6
This trap indicates that MELT test finished successfully, and show the result of the melt test This trap will send when the MELT test finished successfully.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwTestCommonMeltTestFaileTrap 1.3.6.1.4.1.2011.6.21.1.2.3.0.7
This trap indicates that MELT test fails. This trap will send when the MELT test failed.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwLoopLineTestMeltVerTable 1.3.6.1.4.1.2011.6.21.1.1.1.8
This table provides the information about the MELT chip on the board, including the vendor, hardware version, and software version. The indexes of this table are hwFrameIndex and hwSlotIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwLoopLineTestMeltVerEntry

hwLoopLineTestMeltVerEntry 1.3.6.1.4.1.2011.6.21.1.1.1.8.1
This table provides the information about the MELT chip on the board, including the vendor, hardware version, and software version. The indexes of this entry are hwFrameIndex and hwSlotIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwLoopLineTestMeltVerEntry  

hwLoopLineTestMeltFactory 1.3.6.1.4.1.2011.6.21.1.1.1.8.1.1
MELT chipset manufacturer information Maximum length: 32 Octets
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

hwLoopLineTestMeltChip 1.3.6.1.4.1.2011.6.21.1.1.1.8.1.2
MELT chipset manufacturer hardware information Maximum length: 128 Octets
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..128)  

hwLoopLineTestMeltFirmwareVer 1.3.6.1.4.1.2011.6.21.1.1.1.8.1.3
MELT chipset manufacturer version information Maximum length: 16 Octets
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..16)  

hwLoopLineTestSysConfigPara 1.3.6.1.4.1.2011.6.21.1.1.1.9
OBJECT IDENTIFIER    

hwLoopLineTestSysConfigConvertAB 1.3.6.1.4.1.2011.6.21.1.1.1.9.1
Indicates the polarity of A wire and B wire. Options: 1. normal(1) -default polarity of A wire and B wire 2. reverse(2) -reverse polarity of A wire and B wire 3. invalid(-1) -invalid value Default: normal(1)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), reverse(2), invalid(-1)  

hwLoopLineTestSysConfigCableFactor 1.3.6.1.4.1.2011.6.21.1.1.1.9.2
The cable-factor used to detect significant terminal device capacitance. The cable-factor ranges from 1 to 1000 units of 0.001 (Physical values are 0.001 to 1, default: 0.083).
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 1..1000  

hwLoopLineTestSysConfigSigCapUpperLimit 1.3.6.1.4.1.2011.6.21.1.1.1.9.3
The three parameters(capacitance's upper-limit value, lower-limit value and resistance value) are used to determine the signature's existence. The capacitance ranges from 50nF to 2500nF, default: 1350nF. The capacitance's upper-limit value >= the capacitance's lower-limit value.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 50..2500  

hwLoopLineTestSysConfigSigCapLowerLimit 1.3.6.1.4.1.2011.6.21.1.1.1.9.4
The three parameters(capacitance's upper-limit value, lower-limit value and resistance value) are used to determine the signature's existence. The capacitance ranges from 50nF to 2500nF, default: 250nF. The capacitance's upper-limit value >= the capacitance's lower-limit value.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 50..2500  

hwLoopLineTestSysConfigSigResistance 1.3.6.1.4.1.2011.6.21.1.1.1.9.5
The three parameters(capacitance's upper-limit value, lower-limit value and resistance value) are used to determine the signature's existence. The resistance ranges from 10000ohm to 1000000ohm, default: 55000ohm.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 10000..1000000  

hwONTPotsTestOprTable 1.3.6.1.4.1.2011.6.21.1.1.1.10
This table is used for enabling the POTS port line test of the ONT by setting the test item, test frequency, and test threshold. This test helps operators locate faults and provision services. The indexes of this table are ifindex, hwONTPotsTestONTIndex and hwONTPotsTestONTPstnPortIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwONTPotsTestOprEntry

hwONTPotsTestOprEntry 1.3.6.1.4.1.2011.6.21.1.1.1.10.1
This table is used for enabling the POTS port line test of the ONT by setting the test item, test frequency, and test threshold. This test helps operators locate faults and provision services. The indexes of this entry are ifindex, hwONTPotsTestONTIndex and hwONTPotsTestONTPstnPortIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwONTPotsTestOprEntry  

hwONTPotsTestONTIndex 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.1
ONT ID.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

hwONTPotsTestONTPstnPortIndex 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.2
ONT port ID.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

hwONTPotsTestOprType 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.3
POTS port line Test-operation type. Options: 1. stop(1) -stop a POTS port line test 2. start(2) -start a POTS port line test 3. invalid(-1) -invalid value
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER stop(1), start(2), invalid(-1)  

hwONTPotsTestItem 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.4
POTS port line test item. Options: 1. allMLTTests(1) -outdoor connection test 2. hazardousPotential(2) -hazardous potential test 3. foreignEMF(3) -foreign electromotive force(EMF) test 4. resistiveFaults(4) -resistive faults test 5. receiverOff-hook(5) -receiver off-hook test 6. ringer(6) -ringer impedance test 7. nT1DcSignatureTest(7) -NT1 dc signature test 8. selfTest(8) -self test 9. dialToneMake-breakTest(9) -dial tone make-break test 10. subscriber-line(10) -subscriber line test 11. vendor-specificTest2(11) -vendor-specific test all results are returned in a test result message 12. vendor-specificTest3(12) -vendor-specific test all results are returned in a test result message 13. vendor-specificTest4(13) -vendor-specific test the test results are returned in general purpose buffer ME the ONT must deny a test operation command if bytes 39-40 do not point to a GP buffer 14. vendor-specificTest5(14) -vendor-specific test the test results are returned in general purpose buffer ME the ONT must deny a test operation command if bytes 39-40 do not point to a GP buffer 15. vendor-specificTest6(15) -vendor-specific test the test results are returned in general purpose buffer ME the ONT must deny a test operation command if bytes 39-40 do not point to a GP buffer 16. vendor-specificTest7(16) -vendor-specific test the test results are returned in general purpose buffer ME the ONT must deny a test operation command if bytes 39-40 do not point to a GP buffer
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER allMLTTests(1), hazardousPotential(2), foreignEMF(3), resistiveFaults(4), receiverOff-hook(5), ringer(6), nT1DcSignatureTest(7), selfTest(8), dialToneMake-breakTest(9), subscriber-line(10), vendor-specificTest2(11), vendor-specificTest3(12), vendor-specificTest4(13), vendor-specificTest5(14), vendor-specificTest6(15), vendor-specificTest7(16)  

hwONTPotsTestBusyProcFlag 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.5
Test mode when a line is busy. Options: 1. cancel(1) -deny a test if a line is busy 2. force(2) -forced mode
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER cancel(1), force(2)  

hwONTPotsTestT1Threshold 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.6
Slow dial tone threshold. Options: 1. 0 -Invalid value. It indicates that an ONT will use its default value 2. 100..6000 -Valid value range
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0 | 100..6000  

hwONTPotsTestT2Threshold 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.7
No dial tone threshold. Options: 1. 0 -Invalid value. It indicates that an ONT will use its default value 2. 1000..10000 -Valid value range
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0 | 1000..10000  

hwONTPotsTestT3Threshold 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.8
Slow break dial tone threshold. Options: 1. 0 -Invalid value. It indicates that an ONT will use its default value 2. 100..3000 -Valid value range
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0 | 100..3000  

hwONTPotsTestT4Threshold 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.9
No break dial tone threshold. Options: 1. 0 -Invalid value. It indicates that an ONT will use its default value 2. 1000..3000 -Valid value range
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0 | 1000..3000  

hwONTPotsTestDtmfDigit 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.10
DTMF test number. Options: 1. zero(1) -the test number is 0 2. one(2) -the test number is 1 3. two(3) -the test number is 2 4. three(4) -the test number is 3 5. four(5) -the test number is 4 6. five(6) -the test number is 5 7. six(7) -the test number is 6 8. seven(8) -the test number is 7 9. eight(9) -the test number is 8 10. nine(10) -the test number is 9 11. symbolStar(11) -the test number is * 12. symbolSharp(12)-the test number is # 13. default(13) -use the default value (number) of the system
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER zero(1), one(2), two(3), three(4), four(5), five(6), six(7), seven(8), eight(9), nine(10), symbolStar(11), symbolSharp(12), default(13)  

hwONTPotsTestDialType 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.11
The dialling type of dialling tone test. Options: 1. dtmf(1) -dtmf type 2. pulse(2) -pulse type
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER dtmf(1), pulse(2)  

hwONTPotsTestDialToneFreq1 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.12
The frequency1 in the dialling tone test. 0 -unused Unit: Hz
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

hwONTPotsTestDialToneFreq2 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.13
The frequency2 in the dialling tone test. 0 -unused Unit: Hz
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

hwONTPotsTestDialToneFreq3 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.14
The frequency3 in the dialling tone test. 0 -unused Unit: Hz
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

hwONTPotsTestDialToneEnergyThreshold 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.15
The value of energy threshold in the dialling tone test. Valid value: 1. 0x00: unspecified 2. 0x01-0xFD: -0.1 dBm0 to -25.3 dBm0 Unit: 0.1 dBm0
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

hwONTPotsTestIdleChannelEnergyThreshold 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.16
The value of energy threshold in the dialling tone test when the line is in the idle state. Valid value: 1. 0x00: unspecified 2. 0x01-0x5A: -1 dBm0 to -90 dBm0 Unit: 1 dBm0
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

hwONTPotsTestDCHazardousVoltThreshold 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.17
The value of DC voltage threshold in the hazardous potential test. 0x00 -unspecified Unit: volt
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

hwONTPotsTestACHazardousVoltThreshold 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.18
The value of AC voltage threshold in the hazardous potential test. 0x00 -unspecified Unit: volt.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

hwONTPotsTestDCForeignVoltThreshold 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.19
The value of DC voltage threshold in the foreign volt test. 0x00 -unspecified Unit: volt
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

hwONTPotsTestACForeignVoltThreshold 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.20
The value of AC voltage threshold in the foreign volt test. 0x00 -unspecified Unit: volt
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

hwONTPotsTestAGBGResistanceThreshold 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.21
The resistance (tip to ground, ring to ground) threshold in the resistive faults test. 0x00 -unspecified Unit: kilohm
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

hwONTPotsTestABResistanceThreshold 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.22
The resistance (tip to ring) threshold in the resistive faults test. 0x00 -unspecified Unit: kilohm
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

hwONTPotsTestRingerEquivMinThreshold 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.23
Ringer equivalence minimum threshold. 0x00 -unspecified Unit: 0.01 REN
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

hwONTPotsTestRingerEquivMaxThreshold 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.24
Ringer equivalence maximum threshold. 0x00 -unspecified Unit: 0.01 REN
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

hwONTPotsTestMLTResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.25
MLT qualitative test result. Options: 1. failed(1) -a test fails 2. passOrNotRun(2) -a test passes or the test does not run
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER failed(1), passOrNotRun(2)  

hwONTPotsTestHazardousVoltResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.26
Hazardous volt test result. Options: 1. failed(1) -a test fails 2. passOrNotRun(2) -a test passes or the test does not run
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER failed(1), passOrNotRun(2)  

hwONTPotsTestEMFResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.27
EMF test result. Options: 1. failed(1) -a test fails 2. passOrNotRun(2) -a test passes or the test does not run
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER failed(1), passOrNotRun(2)  

hwONTPotsTestResistacneResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.28
Resistacne test result. Options: 1. failed(1) -a test fails 2. passOrNotRun(2) -a test passes or the test does not run
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER failed(1), passOrNotRun(2)  

hwONTPotsTestOffHookResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.29
The off-hook test result. Options: 1. failed(1) -a test fails 2. passOrNotRun(2) -a test passes or the test does not run
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER failed(1), passOrNotRun(2)  

hwONTPotsTestRingerResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.30
Ringer test result. Options: 1. failed(1) -a test fails 2. passOrNotRun(2) -a test passes or the test does not run
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER failed(1), passOrNotRun(2)  

hwONTPotsTestNT1DCSignalResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.31
NT1 DC Signal test result. Options: 1. failed(1) -a test fails 2. passOrNotRun(2) -a test passes or the test does not run
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER failed(1), passOrNotRun(2)  

hwONTPotsTestSelfTestResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.32
Self test result. Options: 1. failed(1) -a test fails 2. passOrNotRun(2) -a test passes or the test does not run 3. notCompleted(3) -a test is not complete yet
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER failed(1), passOrNotRun(2), notCompleted(3)  

hwONTPotsTestDrawDialToneResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.33
Draw dialling tone test result. Options: 1. notRun(1) -a test does not run 2. couldNotDraw1(3) -a test fails to draw 3. couldNotDraw2(4) -a test fails to draw 4. slowDraw1(5) -slow draw 5. slowDraw2(6) -slow draw 6. pass1(7) -a test passes 7. pass2(8) -a test passes
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notRun(1), couldNotDraw1(3), couldNotDraw2(4), slowDraw1(5), slowDraw2(6), pass1(7), pass2(8)  

hwONTPotsTestBreakDialToneResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.34
The break dialling tone test result. Options: 1. notRun(1) -a test does not run 2. couldNotDraw1(3) -a test fails to draw 3. couldNotDraw2(4) -a test fails to draw 4. slowDraw1(5) -slow draw 5. slowDraw2(6) -slow draw 6. pass1(7) -a test passes 7. pass2(8) -a test passes
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notRun(1), couldNotDraw1(3), couldNotDraw2(4), slowDraw1(5), slowDraw2(6), pass1(7), pass2(8)  

hwONTPotsTestQuietEnergyResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.35
The quiet energy test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is not reported 3. failMeasurementReported(4) -a test fails the measurement is reported 4. passMeasurementNotReported(7) -a test passes the measurement is not reported 5. passMeasurementReported(8) -a test passes the measurement is reported
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notRun(1), failMeasurementNotReported(3), failMeasurementReported(4), passMeasurementNotReported(7), passMeasurementReported(8)  

hwONTPotsTestDialToneEnergyResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.36
The dialling tone energy test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is not reported 3. failMeasurementReported(4) -a test fails. the measurement is reported 4. passMeasurementNotReported(7) -a test passes the measurement is not reported 5. passMeasurementReported(8) -a test passes the measurement is reported
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notRun(1), failMeasurementNotReported(3), failMeasurementReported(4), passMeasurementNotReported(7), passMeasurementReported(8)  

hwONTPotsTestLoopDCAGVoltResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.37
The DC A-G (tip to ground) volt loop test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is not reported 3. failMeasurementReported(4) -a test fails the measurement is reported 4. passMeasurementNotReported(7) -a test passes the measurement is not reported 5. passMeasurementReported(8) -a test passes the measurement is reported
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notRun(1), failMeasurementNotReported(3), failMeasurementReported(4), passMeasurementNotReported(7), passMeasurementReported(8)  

hwONTPotsTestLoopDCBGVoltResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.38
The DC B-G (ring to ground) volt loop test result. Options: 1. notRun(1) -a test does not run. 2. failMeasurementNotReported(3) -a test fails the measurement is not reported 3. failMeasurementReported(4) -a test fails the measurement is reported 4. passMeasurementNotReported(7) -a test passes the measurement is not reported 5. passMeasurementReported(8) -a test passes the measurement is reported
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notRun(1), failMeasurementNotReported(3), failMeasurementReported(4), passMeasurementNotReported(7), passMeasurementReported(8)  

hwONTPotsTestLoopACAGVoltResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.39
The AC A-G (tip to ground) volt loop test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is not reported 3. failMeasurementReported(4) -a test fails the measurement is reported 4. passMeasurementNotReported(7) -a test passes the measurement is not reported 5. passMeasurementReported(8) -a test passes the measurement is reported
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notRun(1), failMeasurementNotReported(3), failMeasurementReported(4), passMeasurementNotReported(7), passMeasurementReported(8)  

hwONTPotsTestLoopACBGVoltResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.40
The AC B-G (ring to ground) volt loop test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is not reported 3. failMeasurementReported(4) -a test fails the measurement is reported 4. passMeasurementNotReported(7) -a test passes the measurement is not reported 5. passMeasurementReported(8) -a test passes the measurement is reported
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notRun(1), failMeasurementNotReported(3), failMeasurementReported(4), passMeasurementNotReported(7), passMeasurementReported(8)  

hwONTPotsTestLoopResistanceAGResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.41
The A-G (ring to ground) resistance loop test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is not reported 3. failMeasurementReported(4) -a test fails the measurement is reported 4. passMeasurementNotReported(7) -a test passes the measurement is not reported 5. passMeasurementReported(8) -a test passes the measurement is reported
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notRun(1), failMeasurementNotReported(3), failMeasurementReported(4), passMeasurementNotReported(7), passMeasurementReported(8)  

hwONTPotsTestLoopResistanceBGResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.42
The B-G (ring to ground) resistance loop test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is not reported 3. failMeasurementReported(4) -a test fails the measurement is reported 4. passMeasurementNotReported(7) -a test passes the measurement is not reported 5. passMeasurementReported(8) -a test passes the measurement is reported
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notRun(1), failMeasurementNotReported(3), failMeasurementReported(4), passMeasurementNotReported(7), passMeasurementReported(8)  

hwONTPotsTestLoopResistanceABResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.43
The A-B (tip to ring) resistance loop test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is not reported 3. failMeasurementReported(4) -a test fails the measurement is reported 4. passMeasurementNotReported(7) -a test passes the measurement is not reported 5. passMeasurementReported(8) -a test passes the measurement is reported
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notRun(1), failMeasurementNotReported(3), failMeasurementReported(4), passMeasurementNotReported(7), passMeasurementReported(8)  

hwONTPotsTestLoopRingerLoadTestResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.44
The ringer load Loop test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is not reported 3. failMeasurementReported(4) -a test fails the measurement is reported 4. passMeasurementNotReported(7) -a test passes the measurement is not reported 5. passMeasurementReported(8) -a test passes the measurement is reported
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notRun(1), failMeasurementNotReported(3), failMeasurementReported(4), passMeasurementNotReported(7), passMeasurementReported(8)  

hwONTPotsTestDrawDialToneTimeValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.45
The draw dial tone test result. Valid only if value of hwONTPotsTestDrawDialToneResult is couldNotDraw2(4), slowDraw2(6) or pass2(8). Unit: 100ms. Step: 100ms.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwONTPotsTestBreakDialToneTimeValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.46
The break dial tone test result. Valid only if value of hwONTPotsTestBreakDialToneResult is couldNotDraw2(4), slowDraw2(6) or pass2(8). Unit: 100ms. Step: 100 ms.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwONTPotsTestQuietEnergyValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.47
The quiet energy test result. Valid only if value of hwONTPotsTestQuietEnergyResult is failMeasurementReported(4) or passMeasurementReported(8). Values: 0-90 : 0 dBm0 to -90 dBm0 Step: 1 dBm0
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..90  

hwONTPotsTestDialToneEnergyValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.48
The dial energy test result. Valid only if value of hwONTPotsTestDialToneEnergyResult is failMeasurementReported(4) or passMeasurementReported(8). Values: 0-255 : 0 dBm0 to -25.5 dBm0 Values above 0 dBm0 are reported as 0. Step: 0.1 dBm0
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

hwONTPotsTestLoopDCAGVoltValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.49
The DC A-G(Tip-ground) volt Loop test result or Subscriber line test result. 2s complement, resolution 1V. Valid only if value of hwONTPotsTestLoopDCAGVoltResult is failMeasurementReported(4) or passMeasurementReported(8) when loop tested. Valid only if value of hwONTPotsTestSubscriberLineTestResult is not testTimeout(29) or testFailed(30) or invalid(-1) when subscriber line test. Unit: volt.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwONTPotsTestLoopDCBGVoltValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.50
The DC B-G(Ring-ground) volt Loop test result or Subscriber line test result. 2s complement, resolution 1V. Valid only if value of hwONTPotsTestLoopDCBGVoltResult is failMeasurementReported(4) or passMeasurementReported(8) when loop tested. Valid only if value of hwONTPotsTestSubscriberLineTestResult is not testTimeout(29) or testFailed(30) or invalid(-1) when subscriber line test. Unit: volt.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwONTPotsTestLoopACAGVoltValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.51
The AC A-G(Tip-ground) volt Loop test result or Subscriber line test result. Valid only if value of hwONTPotsTestLoopACAGVoltResult is failMeasurementReported(4) or passMeasurementReported(8) when loop tested. Valid only if value of hwONTPotsTestSubscriberLineTestResult is not testTimeout(29) or testFailed(30) or invalid(-1) when subscriber line test. Unit: volt.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwONTPotsTestLoopACBGVoltValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.52
The AC B-G(Ring-ground) volt Loop test result or Subscriber line test result. Valid only if value of hwONTPotsTestLoopACBGVoltResult is failMeasurementReported(4) or passMeasurementReported(8) when loop tested. Valid only if value of hwONTPotsTestSubscriberLineTestResult is not testTimeout(29) or testFailed(30) or invalid(-1) when subscriber line test. Unit: volt.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwONTPotsTestLoopResistanceAGValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.53
The A-G (tip to ground) resistance loop test result or Subscriber line test result. Unit: kilohm. Infinite resistance: 65535. Valid only if value of hwONTPotsTestLoopResistanceAGResult is failMeasurementReported(4) or passMeasurementReported(8) when loop tested. Valid only if value of hwONTPotsTestSubscriberLineTestResult is not testTimeout(29) or testFailed(30) or invalid(-1) when subscriber line test.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..65535  

hwONTPotsTestLoopResistanceBGValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.54
The B-G (ring to ground) resistance loop test result or Subscriber line test result. Unit: kilohm. Infinite resistance: 65535. Valid only if value of hwONTPotsTestLoopResistanceAGResult is failMeasurementReported(4) or passMeasurementReported(8) when loop tested. Valid only if value of hwONTPotsTestSubscriberLineTestResult is not testTimeout(29) or testFailed(30) or invalid(-1) when subscriber line test.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..65535  

hwONTPotsTestLoopResistanceABValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.55
The A-B (tip to ring) resistance loop test result or Subscriber line test result. Unit: kilohm. Infinite resistance: 65535. Valid only if value of hwONTPotsTestLoopResistanceAGResult is failMeasurementReported(4) or passMeasurementReported(8) when loop tested. Valid only if value of hwONTPotsTestSubscriberLineTestResult is not testTimeout(29) or testFailed(30) or invalid(-1) when subscriber line test.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwONTPotsTestLoopRingerLoadTestValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.56
The ringer load test result. Valid only if value of hwONTPotsTestLoopRingerLoadTestResult is failMeasurementReported(4) or passMeasurementReported(8). Unit: 0.1 REN.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwONTPotsTestSubscriberLineTestResult 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.57
The subscriber line test result. Options: 1. normal(1) -subscriber line test normal 2. acCurrentAbnormal(12) -AC current abnormal 3. dcCurrentAbnormal(13) -DC current abnormal 4. loopCurrentAbnormal(14) -loop current abnormal 5. loopResistanceAbnormal(15) -loop resistance abnormal 6. insulatingResistanceAbnormal(16) -insulating resistance abnormal 7. capacitanceAbnormal(17) -capacitance abnormal 8. impedanceAbnormal(18) -impedance abnormal 9. insulatingNotGood(22) -insulating not good 10. brokenLines(23) -broken lines 11. lineMixing(24) -line mixing 12. connectedToGround(25) -connected to ground 13. abLinereversal(26) -ABLine reversal 14. lineLeaking(27) -line leaking 15. phoneDisconnect(28) -phone disconnect 16. testTimeout(29) -test is time out 17. testFailed(30) -test failed 18. invalid(-1) -a test does not run
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), acCurrentAbnormal(12), dcCurrentAbnormal(13), loopCurrentAbnormal(14), loopResistanceAbnormal(15), insulatingResistanceAbnormal(16), capacitanceAbnormal(17), impedanceAbnormal(18), insulatingNotGood(22), brokenLines(23), lineMixing(24), connectedToGround(25), abLinereversal(26), lineLeaking(27), phoneDisconnect(28), testTimeout(29), testFailed(30), invalid(-1)  

hwONTPotsTestLoopDCABVoltValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.58
The DC A-B (tip-Ring) volt result of subscriber line test. Unit: volt.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwONTPotsTestLoopACABVoltValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.59
The AC A-B (Tip-Ring) volt result of subscriber line test. Unit: volt.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwONTPotsTestLoopAGCapacitanceValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.60
The A->G (Tip-Ground) capacitance result of subscriber line test. Unit: nF
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwONTPotsTestLoopBGCapacitanceValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.61
The B->G (Ring-Ground) capacitance result of subscriber line test. Unit: nF
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwONTPotsTestLoopABCapacitanceValue 1.3.6.1.4.1.2011.6.21.1.1.1.10.1.62
The A->B (Tip-Ring) capacitance result of subscriber line test. Unit: nF
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwPortTestingListOprTable 1.3.6.1.4.1.2011.6.21.1.1.1.11
This table is used to query the ports under a test by board. The indexes of this table are hwFrameIndex and hwSlotIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwPortTestingListOprEntry

hwPortTestingListOprEntry 1.3.6.1.4.1.2011.6.21.1.1.1.11.1
This table is used to query the ports under a test by board. The indexes of this entry are hwFrameIndex and hwSlotIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwPortTestingListOprEntry  

hwMeltTestingPortList 1.3.6.1.4.1.2011.6.21.1.1.1.11.1.1
List of ports under a MELT test on a board. The result is analyzed as follow: If a bit in the bit string is set to 1, it indicates that the corresponding port is under a MELT test. For example, if port 8 is under a MELT test, the eighth character of the string is set to 1, and 0000 0000 1000 0000, namely, # 0x00 0x80 is issued. Note that the value of the bit type starts from 0.
Status: current Access: read-only
OBJECT-TYPE    
  BITS port0(0), port1(1), port2(2), port3(3), port4(4), port5(5), port6(6), port7(7), port8(8), port9(9), port10(10), port11(11), port12(12), port13(13), port14(14), port15(15), port16(16), port17(17), port18(18), port19(19), port20(20), port21(21), port22(22), port23(23), port24(24), port25(25), port26(26), port27(27), port28(28), port29(29), port30(30), port31(31), port32(32), port33(33), port34(34), port35(35), port36(36), port37(37), port38(38), port39(39), port40(40), port41(41), port42(42), port43(43), port44(44), port45(45), port46(46), port47(47), port48(48), port49(49), port50(50), port51(51), port52(52), port53(53), port54(54), port55(55), port56(56), port57(57), port58(58), port59(59), port60(60), port61(61), port62(62), port63(63)  

hwSearchToneTestingPortList 1.3.6.1.4.1.2011.6.21.1.1.1.11.1.2
List of ports under a searching tone test on a board. The result is analyzed as follow: If a bit in the bit string is set to 1, it indicates that the corresponding port is under a searching tone test. For example, if port 8 is under MELT test, the eighth character of the string is set to 1, and 0000 0000 1000 0000, namely, # 0x00 0x80 is issued. Note that the value of the bit type starts from 0.
Status: current Access: read-only
OBJECT-TYPE    
  BITS port0(0), port1(1), port2(2), port3(3), port4(4), port5(5), port6(6), port7(7), port8(8), port9(9), port10(10), port11(11), port12(12), port13(13), port14(14), port15(15), port16(16), port17(17), port18(18), port19(19), port20(20), port21(21), port22(22), port23(23), port24(24), port25(25), port26(26), port27(27), port28(28), port29(29), port30(30), port31(31), port32(32), port33(33), port34(34), port35(35), port36(36), port37(37), port38(38), port39(39), port40(40), port41(41), port42(42), port43(43), port44(44), port45(45), port46(46), port47(47), port48(48), port49(49), port50(50), port51(51), port52(52), port53(53), port54(54), port55(55), port56(56), port57(57), port58(58), port59(59), port60(60), port61(61), port62(62), port63(63)  

hwWettingCurrentOprTable 1.3.6.1.4.1.2011.6.21.1.1.1.12
This table is used for enabling the wetting current by setting the wetting current's working voltage, maximum voltage and slope. The index of this table is ifindex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwWettingCurrentOprEntry

hwWettingCurrentOprEntry 1.3.6.1.4.1.2011.6.21.1.1.1.12.1
This table is used for enabling the wetting current by setting the wetting current's working voltage, maximum voltage and slope. The index of this entry is ifindex.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwWettingCurrentOprEntry  

hwWettingCurrentOprStatus 1.3.6.1.4.1.2011.6.21.1.1.1.12.1.1
Wetting Current operation type. Options: 1. enabled(1) -enable a wetting current port 2. disabled(2) -disable a wetting current port 3. invalid(-1) -invalid value enabled(1) and disabled(2) options are available in the set operation. enabled(1), disabled(2) and invalid(-1) options are available in the get operation.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), invalid(-1)  

hwWettingCurrentOprWorkingVoltage 1.3.6.1.4.1.2011.6.21.1.1.1.12.1.2
Indicates the working voltage of a wetting current port. Options: 1. -1 -Invalid value 2. 1..120 -Valid value range Default: 90 Unit: volt
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1 | 1..120  

hwWettingCurrentOprMaximumVoltage 1.3.6.1.4.1.2011.6.21.1.1.1.12.1.3
Indicates the maximum voltage of a wetting current port. Options: 1. -1 -Invalid value 2. 1..120 -Valid value range Default: 30 Unit: volt
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1 | 1..120  

hwWettingCurrentOprSlope 1.3.6.1.4.1.2011.6.21.1.1.1.12.1.4
Indicates the slope of a wetting current port. Options: 1. -1 -Invalid value 2. 200..20000 -Valid value range Default: 200 Unit: volt per second
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1 | 200..20000