ERICSSON-ELN-TRAP-MIB

File: ERICSSON-ELN-TRAP-MIB.mib (9511 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
SNMPv2-MIB PEM-STANDARD ERICSSON-ELN-MIB
ERICSSON-ELN-SMI

Imported symbols

MODULE-IDENTITY OBJECT-TYPE TimeTicks
mib-2 NOTIFICATION-TYPE DisplayString
NOTIFICATION-GROUP MODULE-COMPLIANCE snmpTraps
managedObjectClass managedObjectInstance sequenceNumber
perceivedSeverity eventTime eventTypePem
probableCause elnMainBoardTemperature elnMainBoardTemperatureLimit
eln

Defined Values

elnTrapMIB 1.3.6.1.4.1.193.109.2
This MIB module defines the Traps for the ELN
MODULE-IDENTITY    

elnTrap 1.3.6.1.4.1.193.109.2.0
OBJECT IDENTIFIER    

elnStart 1.3.6.1.4.1.193.109.2.0.1
The switch has started / restarted.
Status: current Access: read-only
NOTIFICATION-TYPE    

elnLinkDown 1.3.6.1.4.1.193.109.2.0.2
The agent has detected that ifOperStatus for one communication link is about to enter the down state.
Status: current Access: read-only
NOTIFICATION-TYPE    

elnLinkUp 1.3.6.1.4.1.193.109.2.0.3
The agent has detected ifOperStatus for one communication links has left down state and transitioned into another state.
Status: current Access: read-only
NOTIFICATION-TYPE    

elnOverheat 1.3.6.1.4.1.193.109.2.0.4
The on board temperature sensor has detected an overheat condition.
Status: current Access: read-only
NOTIFICATION-TYPE    

elnFanFail 1.3.6.1.4.1.193.109.2.0.5
One or more fans is not working.
Status: current Access: read-only
NOTIFICATION-TYPE    

elnPowerSupplyFail 1.3.6.1.4.1.193.109.2.0.6
One or more sources of power has failed. Presumably a redundant power-supply has taken over.
Status: current Access: read-only
NOTIFICATION-TYPE    

elnPowerBackupFail 1.3.6.1.4.1.193.109.2.0.7
One or more sources of backup power has failed.
Status: current Access: read-only
NOTIFICATION-TYPE    

elnCabinetDoorOpen 1.3.6.1.4.1.193.109.2.0.8
The door to the cabinet has been opened.
Status: current Access: read-only
NOTIFICATION-TYPE    

elnHighTrafficLoad 1.3.6.1.4.1.193.109.2.0.9
The number of free Cell Descriptors in the network processor has fallen below a threshold value.
Status: current Access: read-only
NOTIFICATION-TYPE    

elnOverheatOK 1.3.6.1.4.1.193.109.2.0.11
An on board temperature sensor has detected that the overheat condition has ceased.
Status: current Access: read-only
NOTIFICATION-TYPE    

elnFanOK 1.3.6.1.4.1.193.109.2.0.12
The fan is working again after a failure.
Status: current Access: read-only
NOTIFICATION-TYPE    

elnPowerSupplyOK 1.3.6.1.4.1.193.109.2.0.13
All sources of power is working again after a failure.
Status: current Access: read-only
NOTIFICATION-TYPE    

elnPowerBackupOK 1.3.6.1.4.1.193.109.2.0.14
All sources of backup power is working again after a failure.
Status: current Access: read-only
NOTIFICATION-TYPE