DL5400-MIB

File: DL5400-MIB.mib (76134 bytes)

Imported modules

RFC-1212 RFC-1215 RFC1155-SMI

Imported symbols

OBJECT-TYPE TRAP-TYPE enterprises
IpAddress TimeTicks Counter

Defined Types

DisplayString  
OCTET STRING    

DL5400Validation  
INTEGER valid(1), invalid(2)    

DL5400commBaudRate  
INTEGER bps1200(1), bps2400(2), bps4800(3), bps9600(4), bps19200(5), bps38400(6), bps57600(7), bps115200(8)    

DL5400commParity  
INTEGER even(1), odd(2), none(3)    

DL5400commStopBits  
INTEGER one(1), oneAndHalf(2), two(3)    

DL5400commNumDataBits  
INTEGER seven(7), eight(8)    

DL5400commFlowControl  
INTEGER xoffUntilXon(1), xoffUntilAny(2), hwFlowControl(3), none(4)    

TODYear  
INTEGER 0..9999    

TODMonth  
INTEGER 1..12    

TODDay  
INTEGER 1..31    

TODHour  
INTEGER 0..23    

TODMinute  
INTEGER 0..59    

TODSecond  
INTEGER 0..59    

DL5400CardId  
INTEGER mpm(1), pp(2), enet(3), ds1(4)    

DL5400PortId  
INTEGER dte(1), nmsEthernet(2), comm1(3), comm2(4), net1(5), net2(6), net3(7), net4(8), net5(9), net6(10), net7(11), net8(12)    

DL5400TxClkSrc  
INTEGER internalClock(1), externalClock(2), rcvrdTiming(3), autoTiming(4)    

DL5400Event  
INTEGER ev-mod-appear(1), ev-mod-disappear(2), ev-system-reset(3), ev-system-initialized(4), ev-timeofday-changed(5), ev-admin-isnr(6), ev-admin-oos(7), ev-admin-oosmt(8), ev-cuisession-inactivitytimeout(9), ev-clkref-configchanged(10), ev-selftest-fail(11), ev-ram-test-fail(12), ev-rom-checksum-fail(13), ev-flash-checksum-fail(14), ev-time-not-set(15), ev-unit-restart(16), ev-lamptest-start(17), ev-lamptest-end(18), ev-mgmt-post-fail(19), ev-mgmt-post-fail-remit(20), ev-front-high-temperature(21), ev-front-high-temperature-remit(22), ev-back-high-temperature(23), ev-back-high-temperature-remit(24), ev-external-major-alarm-input(25), ev-external-major-alarm-input-end(26), ev-external-minor-alarm-input(27), ev-external-minor-alarm-input-end(28), ev-external-status-alarm-input(29), ev-external-status-alarm-input-end(30), ev-primary-clk-fail(31), ev-primary-clk-ok(32), ev-secondary-clk-fail(33), ev-secondary-clk-ok(34), ev-ext-clk-fail(35), ev-ext-clk-ok(36), ev-fan1-fail(37), ev-fan1-ok(38), ev-fan2-fail(39), ev-fan2-ok(40), ev-ps-fan-fail(41), ev-ps-fan-ok(42), ev-packet-processor-post-fail(43), ev-packet-processor-post-ok(44), ev-packet-processor-missing(45), ev-packet-processor-ok(46), ev-voltage-exceeds(47), ev-voltage-ok(48), ev-module-processor-fail(49), ev-module-processor-ok(50), ev-mod-cfg-mismatch(51), ev-mod-cfg-match(52), ev-use-primary-clk(53), ev-use-secondary-clk(54), ev-use-internal-clk(55), ev-use-rx-clk1(56), ev-use-rx-clk2(57), ev-use-rx-clk3(58), ev-use-rx-clk4(59), ev-use-rx-clk5(60), ev-use-rx-clk6(61), ev-use-rx-clk7(62), ev-use-rx-clk8(63), ev-mlppp-post-fail(64), ev-mlppp-post-fail-remit(65), ev-mlppp-module-missing(66), ev-mlppp-module-ok(67), ev-mlppp-insufficient-links(68), ev-mlppp-insufficient-links-remit(69), ev-mod-fail(70), ev-mod-up(71), ev-mod-no-resp(72), ev-mod-hello(73), ev-mod-init-fail(74), ev-mod-init-ok(75), ev-mod-some-ports-failed(76), ev-mod-some-ports-ok(77), ev-mod-all-ports-failed(78), ev-mod-all-ports-ok(79), ev-lost-signal(100), ev-lost-signal-remit(101), ev-lof(102), ev-lof-remit(103), ev-ais(104), ev-ais-remit(105), ev-rai(106), ev-rai-remit(107), ev-red-alarm(108), ev-red-alarm-remit(109), ev-exceeded-cv-consec-sec(110), ev-exceeded-cv-consec-sec-remit(111), ev-exceeded-ses-consec-sec(112), ev-exceeded-ses-consec-sec-remit(113), ev-exceeded-uas-consec-sec(114), ev-exceeded-uas-consec-sec-remit(115), ev-exceeded-pcv-15min-minor-threshold(116), ev-exceeded-pcv-15min-minor-threshold-remit(117), ev-exceeded-pcv-15min-major-threshold(118), ev-exceeded-pcv-15min-major-threshold-remit(119), ev-exceeded-es-15min-minor-threshold(120), ev-exceeded-es-15min-minor-threshold-remit(121), ev-exceeded-es-15min-major-threshold(122), ev-exceeded-es-15min-major-threshold-remit(123), ev-exceeded-ses-15min-minor-threshold(124), ev-exceeded-ses-15min-minor-threshold-remit(125), ev-exceeded-ses-15min-major-threshold(126), ev-exceeded-ses-15min-major-threshold-remit(127), ev-exceeded-sas-15min-minor-threshold(128), ev-exceeded-sas-15min-minor-threshold-remit(129), ev-exceeded-sas-15min-major-threshold(130), ev-exceeded-sas-15min-major-threshold-remit(131), ev-exceeded-uas-15min-minor-threshold(132), ev-exceeded-uas-15min-minor-threshold-remit(133), ev-exceeded-uas-15min-major-threshold(134), ev-exceeded-uas-15min-major-threshold-remit(135), ev-exceeded-pcv-24hr-minor-threshold(136), ev-exceeded-pcv-24hr-minor-threshold-remit(137), ev-exceeded-pcv-24hr-major-threshold(138), ev-exceeded-pcv-24hr-major-threshold-remit(139), ev-exceeded-es-24hr-minor-threshold(140), ev-exceeded-es-24hr-minor-threshold-remit(141), ev-exceeded-es-24hr-major-threshold(142), ev-exceeded-es-24hr-major-threshold-remit(143), ev-exceeded-ses-24hr-minor-threshold(144), ev-exceeded-ses-24hr-minor-threshold-remit(145), ev-exceeded-ses-24hr-major-threshold(146), ev-exceeded-ses-24hr-major-threshold-remit(147), ev-exceeded-sas-24hr-minor-threshold(148), ev-exceeded-sas-24hr-minor-threshold-remit(149), ev-exceeded-sas-24hr-major-threshold(150), ev-exceeded-sas-24hr-major-threshold-remit(151), ev-exceeded-uas-24hr-minor-threshold(152), ev-exceeded-uas-24hr-minor-threshold-remit(153), ev-exceeded-uas-24hr-major-threshold(154), ev-exceeded-uas-24hr-major-threshold-remit(155), ev-net-local-loopback-start(156), ev-net-local-loopback-end(157), ev-net-remote-loopback-start(158), ev-net-remote-loopback-end(159), ev-net-payload-loopback-start(160), ev-net-payload-loopback-end(161), ev-net-BERT-start(162), ev-net-BERT-end(163), ev-ppp-echo-timeout(164), ev-ppp-echo-timeout-remit(165), ev-ppp-loopback-line(166), ev-ppp-loopback-line-remit(167), ev-ppp-link-fallback(168), ev-ppp-link-fallback-remit(169), ev-dte-local-loopback-start(170), ev-dte-local-loopback-end(171), ev-dte-remote-loopback-start(172), ev-dte-remote-loopback-end(173), ev-mlppp-link-down(174), ev-mlppp-link-up(175)    

DteEnetEntry  
SEQUENCE    
  dteEnetIndex INTEGER
  dteEnetIpAddress IpAddress
  dteEnetSubnetMask IpAddress
  dteEnetMacAddress OCTET STRING
  dteEnetProtocol INTEGER
  dteEnetOper INTEGER
  dteEnetMode INTEGER
  dteEnetOperStatus DisplayString
  dteEnetModeStatus DisplayString

NetPortEntry  
SEQUENCE    
  netPortIndex INTEGER
  netAdmin INTEGER
  netFramingFormat INTEGER
  netLineCode INTEGER
  netLBO INTEGER
  netEGL INTEGER
  netFDL INTEGER
  netSetCode INTEGER
  netClock INTEGER
  netFrameStatus DisplayString
  netFrameUpTime TimeTicks

UnitSnmpTrapAddrEntry  
SEQUENCE    
  unitSnmpTrapHostAddr IpAddress
  unitSnmpTrapDirection INTEGER

PPPPortEntry  
SEQUENCE    
  pppPortIndex INTEGER
  pppPortInitialMRU INTEGER
  pppPortMagicNumber INTEGER
  pppPortFcsSize INTEGER
  pppPortRestore INTEGER

MLPPPPortEntry  
SEQUENCE    
  mlPPPPortIndex INTEGER
  mlPPPAdmin INTEGER
  mlPPPStatus DisplayString
  mlPPPUpTime TimeTicks
  mlPPPLCPState DisplayString

StaticRoutingEntry  
SEQUENCE    
  routeDestination IpAddress
  routeNetworkMask IpAddress
  routeNextHopAddress IpAddress
  routeMetric INTEGER
  routeDirection INTEGER
  routeStatus DL5400Validation

UnitArpEntry  
SEQUENCE    
  arpEntryNum INTEGER
  arpIPAddress IpAddress
  arpMACAddress OCTET STRING
  arpPortNum INTEGER

UnitAlarmStatusEntry  
SEQUENCE    
  unitAlarmIndex INTEGER
  unitAlarmSeverity INTEGER
  unitAlarmType DL5400Event
  unitAlarmOriginCardNum DL5400CardId
  unitAlarmOriginPortNum DL5400PortId

UnitEventEntry  
SEQUENCE    
  unitEventIndex INTEGER
  unitEventSeverity INTEGER
  unitEventHour TODHour
  unitEventMinute TODMinute
  unitEventSecond TODSecond
  unitEventMonth TODMonth
  unitEventDay TODDay
  unitEventYear TODYear
  unitEventOriginCardNum DL5400CardId
  unitEventOriginPortNum DL5400PortId
  unitEventType DL5400Event

HdlcStatsEntry  
SEQUENCE    
  hdlcPortIndex INTEGER
  hdlcLinkStatusBadFCSc Counter
  hdlcFramesAborted Counter
  hdlcFramesNotAligned Counter
  hdlcOctetsRcv Counter
  hdlcPctsRcv Counter
  hdlcOctetsTrsmt Counter
  hdlcPctsTrsmt Counter

MaintModEntry  
SEQUENCE    
  maintModIndex INTEGER
  maintModStatus DisplayString
  maintOperstatus DisplayString

Defined Values


dl5400 1.3.6.1.4.1.300.110
OBJECT IDENTIFIER    

configuration 1.3.6.1.4.1.300.110.1
OBJECT IDENTIFIER    

alarms 1.3.6.1.4.1.300.110.2
OBJECT IDENTIFIER    

events 1.3.6.1.4.1.300.110.3
OBJECT IDENTIFIER    

statistics 1.3.6.1.4.1.300.110.4
OBJECT IDENTIFIER    

maintenance 1.3.6.1.4.1.300.110.5
OBJECT IDENTIFIER    

unitLevelConfig 1.3.6.1.4.1.300.110.1.1
OBJECT IDENTIFIER    

unitSerialNum 1.3.6.1.4.1.300.110.1.1.1
An ID that uniquely and globally identifies the unit. A Serial Number must consist of printable ASCII characters 0x20..0x7E.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..20)  

unitName 1.3.6.1.4.1.300.110.1.1.2
A descriptive name that identifies the DL5400 unit. Use of this parameter is optional, but recommended to aid management.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..20)  

unitHwRev 1.3.6.1.4.1.300.110.1.1.3
The DL5400 hardware revision.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..4)  

unitSwRev 1.3.6.1.4.1.300.110.1.1.4
The DL5400 software revision.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..7)  

unitMibRev 1.3.6.1.4.1.300.110.1.1.5
The DL5400 MIB revision.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..20)  

unitFrontPnl 1.3.6.1.4.1.300.110.1.1.6
This feature enables (ON) or disables (OFF) the users ability to make changes in the configuration or run tests from the front panel display and buttons.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

unitDateYear 1.3.6.1.4.1.300.110.1.1.7
The DL5400's date: Year.
Status: mandatory Access: read-write
OBJECT-TYPE    
  TODYear  

unitDateMonth 1.3.6.1.4.1.300.110.1.1.8
The DL5400's date: Month.
Status: mandatory Access: read-write
OBJECT-TYPE    
  TODMonth  

unitDateDay 1.3.6.1.4.1.300.110.1.1.9
The DL5400's date: Day.
Status: mandatory Access: read-write
OBJECT-TYPE    
  TODDay  

unitTimeHour 1.3.6.1.4.1.300.110.1.1.10
The DL5400's time: Hour.
Status: mandatory Access: read-write
OBJECT-TYPE    
  TODHour  

unitTimeMinute 1.3.6.1.4.1.300.110.1.1.11
The DL5400's time: Minute.
Status: mandatory Access: read-write
OBJECT-TYPE    
  TODMinute  

unitTimeSecond 1.3.6.1.4.1.300.110.1.1.12
The DL5400's time: Second.
Status: mandatory Access: read-write
OBJECT-TYPE    
  TODSecond  

unitTimezone 1.3.6.1.4.1.300.110.1.1.13
This object is used to indicate the timezone associated with the time of day that exists on DL5400 System. The enumerated values are defined as hours west of Greenwhich, for example, g01Timezone represents the time zone which is 1 hour west of Greenwhich.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER gmtTimezone(1), g01Timezone(2), g02Timezone(3), g03Timezone(4), g04Timezone(5), estTimezone(6), cstTimezone(7), mstTimezone(8), pstTimezone(9), astTimezone(10), hstTimezone(11), g11Timezone(12), g12Timezone(13), g13Timezone(14), g14Timezone(15), g15Timezone(16), g16Timezone(17), g17Timezone(18), g18Timezone(19), g19Timezone(20), g20Timezone(21), g21Timezone(22), g22Timezone(23), g23Timezone(24)  

unitLedStatus 1.3.6.1.4.1.300.110.1.1.14
The defined values have the following description Off - The unit is not equipped or is provision in an out of Service state Green - No alarms, status or test conditions exists for the unit Blink Amber - Test conditions are present in the unit Solid Amber - A minor alarm condition persists in the unit or on some interface of the unit, or the unit is powering up. Red - An Alarm condition persists in the unit or on some interface of the unit Blink-Green - reserved Blink-Red - reserved
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), green(2), blink-Green(3), blink-Amber(4), solid-Amber(5), red(6), blink-Red(7)  

unitTimeStamp 1.3.6.1.4.1.300.110.1.1.15
Time Stamp on the unit of format MM/DD/YYYY HH:MM:SS This will be sent as a varbind along with all the traps to NMS manager
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..20)  

unitModelType 1.3.6.1.4.1.300.110.1.1.16
The unit model type
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ml-pppNxDs1Enet(1)  

unitRouteMode 1.3.6.1.4.1.300.110.1.1.17
Unit Route Mode
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER staticIp(1), fastForward(2)  

unitTelnetConfig 1.3.6.1.4.1.300.110.1.2
OBJECT IDENTIFIER    

unitTelnetIdleTimeout 1.3.6.1.4.1.300.110.1.2.1
This object is used to indicate number of minutes of inactivity required before setting the telnet access point to auto-logoff.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

unitDteEnetCfg 1.3.6.1.4.1.300.110.1.3
OBJECT IDENTIFIER    

dteEnetTable 1.3.6.1.4.1.300.110.1.3.1
Table of all Dte Ethernet ports in the system
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DteEnetEntry

dteEnetEntry 1.3.6.1.4.1.300.110.1.3.1.1
An entry in the dteEnetTable
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DteEnetEntry  

dteEnetIndex 1.3.6.1.4.1.300.110.1.3.1.1.1
The dteEnet port index
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER dte1(1)  

dteEnetIpAddress 1.3.6.1.4.1.300.110.1.3.1.1.2
IP address assigned to the DTE port of the DL5400.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

dteEnetSubnetMask 1.3.6.1.4.1.300.110.1.3.1.1.3
IP Subnet mask assigned to the DTE port of the DL5400.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

dteEnetMacAddress 1.3.6.1.4.1.300.110.1.3.1.1.4
Ethernet MAC address of this dte port
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

dteEnetProtocol 1.3.6.1.4.1.300.110.1.3.1.1.5
Ethernet protocol used by the DL5400. dix is also called Ethernet-II.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ethernet(1), ieee8023(2)  

dteEnetOper 1.3.6.1.4.1.300.110.1.3.1.1.6
Ethernet operation used by the DL5400.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER autodetect(1), tenMb(2), hundredMb(3)  

dteEnetMode 1.3.6.1.4.1.300.110.1.3.1.1.7
Ethernet mode used by the DL5400.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER autodetect(1), halfduplex(2), fullduplex(3)  

dteEnetOperStatus 1.3.6.1.4.1.300.110.1.3.1.1.8
Ethernet operation status
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

dteEnetModeStatus 1.3.6.1.4.1.300.110.1.3.1.1.9
Ethernet Mode status
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

comm1SerialConfig 1.3.6.1.4.1.300.110.1.5
OBJECT IDENTIFIER    

comm1SerialPortState 1.3.6.1.4.1.300.110.1.5.1
This object is used to enable or disable port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

comm1SerialBaudRate 1.3.6.1.4.1.300.110.1.5.2
COMM 1 Baud Rate.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DL5400commBaudRate  

comm1SerialBitsPerWord 1.3.6.1.4.1.300.110.1.5.3
COMM 1 Bits Per Word.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DL5400commNumDataBits  

comm1SerialStopBits 1.3.6.1.4.1.300.110.1.5.4
COMM 1 Stop Bits.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DL5400commStopBits  

comm1SerialParity 1.3.6.1.4.1.300.110.1.5.5
COMM 1 Parity.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DL5400commParity  

comm1SerialFlowControl 1.3.6.1.4.1.300.110.1.5.6
COMM 1 Flow Control.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DL5400commFlowControl  

comm1SerialLogoutOnLos 1.3.6.1.4.1.300.110.1.5.7
This object is used to enable or disable auto-logoff on loss of DSR.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

comm1SerialIdleTimeout 1.3.6.1.4.1.300.110.1.5.8
This object is used to indicate number of minutes of inactivity required before setting this serial access point to auto-logoff.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

comm2SerialConfig 1.3.6.1.4.1.300.110.1.6
OBJECT IDENTIFIER    

comm2SerialPortState 1.3.6.1.4.1.300.110.1.6.1
This object is used to enable or disable port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

comm2SerialBaudRate 1.3.6.1.4.1.300.110.1.6.2
COMM 2 Baud Rate.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DL5400commBaudRate  

comm2SerialBitsPerWord 1.3.6.1.4.1.300.110.1.6.3
COMM 2 Bits Per Word.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DL5400commNumDataBits  

comm2SerialStopBits 1.3.6.1.4.1.300.110.1.6.4
COMM 2 Stop Bits.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DL5400commStopBits  

comm2SerialParity 1.3.6.1.4.1.300.110.1.6.5
COMM 2 Parity.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DL5400commParity  

comm2SerialFlowControl 1.3.6.1.4.1.300.110.1.6.6
COMM 2 Flow Control. HwFlowControl option is not applicable for multidrop serial port when in MultiDrop mode
Status: mandatory Access: read-write
OBJECT-TYPE    
  DL5400commFlowControl  

comm2SerialLogoutOnLos 1.3.6.1.4.1.300.110.1.6.7
This object is used to enable or disable auto-logoff on loss of DSR.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

comm2SerialIdleTimeout 1.3.6.1.4.1.300.110.1.6.8
This object is used to indicate number of minutes of inactivity required before setting this serial access point to auto-logoff.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

comm2InMDmode 1.3.6.1.4.1.300.110.1.6.9
This object indicates if this serial port is in multidrop mode or not.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

comm2InMDId 1.3.6.1.4.1.300.110.1.6.10
Identifies the multidrop session
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

netConfig 1.3.6.1.4.1.300.110.1.7
OBJECT IDENTIFIER    

netPriTxClk 1.3.6.1.4.1.300.110.1.7.1
The primary transmit clock source for DL5400.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DL5400TxClkSrc  

netPriLoopPort 1.3.6.1.4.1.300.110.1.7.2
The primary loop port clock source for DL5400.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

netSecTxClk 1.3.6.1.4.1.300.110.1.7.3
The secondary transmit clock source for DL5400.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DL5400TxClkSrc  

netSecLoopPort 1.3.6.1.4.1.300.110.1.7.4
The secondary loop port clock source for DL5400.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

netExtClkFrequency 1.3.6.1.4.1.300.110.1.7.5
The defined parameters are the external clock frequencies. The user must provision what frequency is to be used
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER freq8kHZ(1), freq1544kHZ(2)  

netPriStatus 1.3.6.1.4.1.300.110.1.7.6
Primary clock operation status
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

netSecStatus 1.3.6.1.4.1.300.110.1.7.7
Secondary clock operation status
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

netActiveStatus 1.3.6.1.4.1.300.110.1.7.8
Active clock operation status
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

netSuppressYeldet 1.3.6.1.4.1.300.110.1.7.9
This enables or disables the suppression of Yellow Alarm (RAI) detection. Applicable in SF Framing
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER suppressYelDet(1), allowYelDet(2)  

netLineType 1.3.6.1.4.1.300.110.1.7.10
Tells if this is a T1 or E1 device
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER t1(1), e1(2)  

netPortTable 1.3.6.1.4.1.300.110.1.7.11
Table of all network port in the system.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NetPortEntry

netPortEntry 1.3.6.1.4.1.300.110.1.7.11.1
An entry in the Net Port Table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NetPortEntry  

netPortIndex 1.3.6.1.4.1.300.110.1.7.11.1.1
The network port index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..8  

netAdmin 1.3.6.1.4.1.300.110.1.7.11.1.2
Tells the Net DS1 Admin state
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER is(1), oos(2), oos-mt(3)  

netFramingFormat 1.3.6.1.4.1.300.110.1.7.11.1.3
This variable describes the Framing Format option for the network port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER esf(2), d4(3)  

netLineCode 1.3.6.1.4.1.300.110.1.7.11.1.4
This variable describes the Line Code option for the network port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER b8zs(2), ami(5)  

netLBO 1.3.6.1.4.1.300.110.1.7.11.1.5
This selects the line build out value in dBs and applies to CSU/DSU mode only.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ft0To133(3), ft133To266(4), ft266To399(5), ft399To533(6), ft533To655(7), lbo-0dB(8), lbo-7p5dB(9), lbo-15dB(10), lbo-22p5dB(11)  

netEGL 1.3.6.1.4.1.300.110.1.7.11.1.6
This selects the equalizer gain limit in dBs and applies to CSU mode only.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER egl-36dB(1), egl-30dB(2)  

netFDL 1.3.6.1.4.1.300.110.1.7.11.1.7
'other' indicates that a protocol other than one following is used. 'dsx1Ansi-T1-403' refers to the FDL exchange recommended by ANSI. 'dsx1Att-54016' refers to ESF FDL exchanges. 'dsx1Fdl-none' indicates that the device does not use the FDL.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), ansi(2), att(3), both(4)  

netSetCode 1.3.6.1.4.1.300.110.1.7.11.1.8
enabled or disabled setCode feature.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

netClock 1.3.6.1.4.1.300.110.1.7.11.1.9
This selects the source of Transmit clock.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER loopTiming(1), sysTiming(3)  

netFrameStatus 1.3.6.1.4.1.300.110.1.7.11.1.10
Framing Operational State.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

netFrameUpTime 1.3.6.1.4.1.300.110.1.7.11.1.11
Tells the Framing UpTime.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

unitSnmpConfig 1.3.6.1.4.1.300.110.1.8
OBJECT IDENTIFIER    

unitSnmpTrapAddrTable 1.3.6.1.4.1.300.110.1.8.1
A list of IP addresses of the management stations along with information on how to direct a trap to that addresss
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UnitSnmpTrapAddrEntry

unitSnmpTrapAddrEntry 1.3.6.1.4.1.300.110.1.8.1.1
An entry in the Snmp trap address table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  UnitSnmpTrapAddrEntry  

unitSnmpTrapHostAddr 1.3.6.1.4.1.300.110.1.8.1.1.1
Specifies the IP address of the management station to which this unit sends traps.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

unitSnmpTrapDirection 1.3.6.1.4.1.300.110.1.8.1.1.2
Specifies the way the trap is to be sent to the host
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), inBand(2), outBand(3)  

unitSnmpTrapDevState 1.3.6.1.4.1.300.110.1.8.2
Specifies whether to forward or block SNMP traps on device.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER forward(1), block(2)  

unitSnmpTrapCommunity 1.3.6.1.4.1.300.110.1.8.3
Specifies the Community Name of the management station to which this unit sends traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

unitPPPConfig 1.3.6.1.4.1.300.110.1.9
OBJECT IDENTIFIER    

pppPortTable 1.3.6.1.4.1.300.110.1.9.1
Table of all network ports in the system.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PPPPortEntry

pppPortEntry 1.3.6.1.4.1.300.110.1.9.1.1
An entry in the PPP Port table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PPPPortEntry  

pppPortIndex 1.3.6.1.4.1.300.110.1.9.1.1.1
Port number of the Net port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER net1(1), net2(2), net3(3), net4(4), net5(5), net6(6), net7(7), net8(8)  

pppPortInitialMRU 1.3.6.1.4.1.300.110.1.9.1.1.2
The initial Maximum Receive Unit (MRU) that the local PPP entity will advertise to the remote entity. If the value of this variable is 0 then the local PPP entity will not advertise any MRU to the remote entity and the default MRU will be assumed. Changing this object will have effect when the link is next restarted.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

pppPortMagicNumber 1.3.6.1.4.1.300.110.1.9.1.1.3
If true(2) then the local node will attempt to perform Magic Number negotiation with the remote node. If false(1) then this negotiation is not performed. In any event, the local node will comply with any magic number negotiations attempted by the remote node, per the PPP specification. Changing this object will have effect when the link is next restarted.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER false(1), true(2)  

pppPortFcsSize 1.3.6.1.4.1.300.110.1.9.1.1.4
The size of the FCS, in bits, the local node will attempt to negotiate for use with the remote node. Regardless of the value of this object, the local node will comply with any FCS size negotiations initiated by the remote node, per the PPP specification. Changing this object will have effect when the link is next restarted.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER size16bits(1), size32bits(2)  

pppPortRestore 1.3.6.1.4.1.300.110.1.9.1.1.5
PPP port restore mode, auto or manual.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), manual(2)  

unitMLPPPConfig 1.3.6.1.4.1.300.110.1.9.2
OBJECT IDENTIFIER    

mlPPPIpAddress 1.3.6.1.4.1.300.110.1.9.2.1
IP Address assigned to the ML-PPP port of DL5400.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

mlPPPSubnetMask 1.3.6.1.4.1.300.110.1.9.2.2
IP Subnet mask assigned to the ML-PPP link of DL5400.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

mlPPPNumberedInterface 1.3.6.1.4.1.300.110.1.9.2.3
Numbered Interface enabled or disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

mlPPPMRRU 1.3.6.1.4.1.300.110.1.9.2.4
Maximum Received Reconstructed Unit of ML-PPP.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mlPPPBundleStatus 1.3.6.1.4.1.300.110.1.9.2.5
Tells the current bundle status
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mlPPPBundleUpTime 1.3.6.1.4.1.300.110.1.9.2.6
The time (in hundredths of a second) since the bundle is up.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

mlPPPIPCPState 1.3.6.1.4.1.300.110.1.9.2.7
The current state of IPCP.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mlPPPPortTable 1.3.6.1.4.1.300.110.1.9.3
Table of all mlppp port in the system.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MLPPPPortEntry

mlPPPPortEntry 1.3.6.1.4.1.300.110.1.9.3.1
An entry in the mlppp Port Table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MLPPPPortEntry  

mlPPPPortIndex 1.3.6.1.4.1.300.110.1.9.3.1.1
The network port index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..8  

mlPPPAdmin 1.3.6.1.4.1.300.110.1.9.3.1.2
Tells the MLPPP Admin State.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER is(1), oos(2), oos-mt(3)  

mlPPPStatus 1.3.6.1.4.1.300.110.1.9.3.1.3
Tells the MLPPP Operational State.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mlPPPUpTime 1.3.6.1.4.1.300.110.1.9.3.1.4
The time (in hundredths of a second) since the MLPPP is up.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

mlPPPLCPState 1.3.6.1.4.1.300.110.1.9.3.1.5
Tells the LCP Operational State.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

unitRouterConfig 1.3.6.1.4.1.300.110.1.10
OBJECT IDENTIFIER    

unitStaticRoutingTable 1.3.6.1.4.1.300.110.1.10.1
Table of all static routing entries in the system.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    StaticRoutingEntry

staticRoutingEntry 1.3.6.1.4.1.300.110.1.10.1.1
An entry in the static routing table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  StaticRoutingEntry  

routeDestination 1.3.6.1.4.1.300.110.1.10.1.1.1
Destination of the static route.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

routeNetworkMask 1.3.6.1.4.1.300.110.1.10.1.1.2
Network Mask
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

routeNextHopAddress 1.3.6.1.4.1.300.110.1.10.1.1.3
Address of the next hop router. The next hop router must be on the same local network as DL5400
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

routeMetric 1.3.6.1.4.1.300.110.1.10.1.1.4
Number of hops between DL5400 and the destination.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

routeDirection 1.3.6.1.4.1.300.110.1.10.1.1.5
Direction of the Route, Network(NUM) or WAN.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wan(1), num(2)  

routeStatus 1.3.6.1.4.1.300.110.1.10.1.1.6
Writing invalid has the effect of deleting this interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DL5400Validation  

unitArpConfig 1.3.6.1.4.1.300.110.1.11
OBJECT IDENTIFIER    

unitClearArpTable 1.3.6.1.4.1.300.110.1.11.1
Clear all arp entries in the system.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER true(1)  

unitArpTable 1.3.6.1.4.1.300.110.1.11.2
Table of all arp entries in the system.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UnitArpEntry

unitArpEntry 1.3.6.1.4.1.300.110.1.11.2.1
An entry in the arp table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  UnitArpEntry  

arpEntryNum 1.3.6.1.4.1.300.110.1.11.2.1.1
Entry Number in the arp table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

arpIPAddress 1.3.6.1.4.1.300.110.1.11.2.1.2
Entry IpAddress in the arp table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

arpMACAddress 1.3.6.1.4.1.300.110.1.11.2.1.3
Entry MAC address in the arp table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

arpPortNum 1.3.6.1.4.1.300.110.1.11.2.1.4
Entry Port Number in the arp table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

unitAlarmConfig 1.3.6.1.4.1.300.110.2.1
OBJECT IDENTIFIER    

unitAlarmStatusTable 1.3.6.1.4.1.300.110.2.1.1
The Unit Level alarms and status table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UnitAlarmStatusEntry

unitAlarmStatusEntry 1.3.6.1.4.1.300.110.2.1.1.1
An Entry in the unit Alarms Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  UnitAlarmStatusEntry  

unitAlarmIndex 1.3.6.1.4.1.300.110.2.1.1.1.1
An index value that uniquely identifies a Unit Level alarm entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

unitAlarmSeverity 1.3.6.1.4.1.300.110.2.1.1.1.2
This parameter indicates the severity of the alarm, or may indicate that the data is status only.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER status(1), minor(2), major(3)  

unitAlarmType 1.3.6.1.4.1.300.110.2.1.1.1.3
This parameter is the code for the alarm or status type. This code is used to index into an array of text strings to present a message to the human operator.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DL5400Event  

unitAlarmOriginCardNum 1.3.6.1.4.1.300.110.2.1.1.1.4
The card type of the device originating the event.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DL5400CardId  

unitAlarmOriginPortNum 1.3.6.1.4.1.300.110.2.1.1.1.5
The port number of the device originating the event.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DL5400PortId  

unitEventTable 1.3.6.1.4.1.300.110.3.1
The Unit Level event history table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UnitEventEntry

unitEventEntry 1.3.6.1.4.1.300.110.3.1.1
An entry in the Unit Level event history table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  UnitEventEntry  

unitEventIndex 1.3.6.1.4.1.300.110.3.1.1.1
An index that uniquely identifies a Unit Level event entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

unitEventSeverity 1.3.6.1.4.1.300.110.3.1.1.2
This parameter indicates whether an entry is status-only or the severity of an alarm entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER status(1), minor(2), major(3), clear(4), information(5)  

unitEventHour 1.3.6.1.4.1.300.110.3.1.1.3
The hour that the event occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TODHour  

unitEventMinute 1.3.6.1.4.1.300.110.3.1.1.4
The minute that the event occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TODMinute  

unitEventSecond 1.3.6.1.4.1.300.110.3.1.1.5
The second that the event occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TODSecond  

unitEventMonth 1.3.6.1.4.1.300.110.3.1.1.6
The month that the event occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TODMonth  

unitEventDay 1.3.6.1.4.1.300.110.3.1.1.7
The day that the event occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TODDay  

unitEventYear 1.3.6.1.4.1.300.110.3.1.1.8
The year that the event occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TODYear  

unitEventOriginCardNum 1.3.6.1.4.1.300.110.3.1.1.9
The card type of the device originating the event.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DL5400CardId  

unitEventOriginPortNum 1.3.6.1.4.1.300.110.3.1.1.10
The port number of the device originating the event.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DL5400PortId  

unitEventType 1.3.6.1.4.1.300.110.3.1.1.11
This parameter is the code for the event type. This code is used to index into an array of text strings to present a message to the human operator.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DL5400Event  

arpStats 1.3.6.1.4.1.300.110.4.1
OBJECT IDENTIFIER    

arpbadLengthField 1.3.6.1.4.1.300.110.4.1.1
Bad Length Field
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

arpunsupportedHardware 1.3.6.1.4.1.300.110.4.1.2
unsupported Hardware
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

arpunsupportedProtocol 1.3.6.1.4.1.300.110.4.1.3
unsupported Protocol
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

arpinvalidSenderAddr 1.3.6.1.4.1.300.110.4.1.4
total number of packets with invalid sender protocol address
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

arpinvalidTargetAddr 1.3.6.1.4.1.300.110.4.1.5
total number of packets with invalid target protocol address
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

arpbadAddress 1.3.6.1.4.1.300.110.4.1.6
bad address
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

arppktsReceived 1.3.6.1.4.1.300.110.4.1.7
total number of packets recieved
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

arpshortPktsReceived 1.3.6.1.4.1.300.110.4.1.8
total number of short packets recieved
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

arppktsFromMeReceived 1.3.6.1.4.1.300.110.4.1.9
total number of packets from me received
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

arpsrcBcstReceived 1.3.6.1.4.1.300.110.4.1.10
total number of source broadcasts received
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

arprepliedSent 1.3.6.1.4.1.300.110.4.1.11
total number of replies sent
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

arpincomingRequests 1.3.6.1.4.1.300.110.4.1.12
total number of incoming requests
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

arprequestSent 1.3.6.1.4.1.300.110.4.1.13
total number of requests sent
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

arpnoMACAddr 1.3.6.1.4.1.300.110.4.1.14
No MAC address
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

hdlcStatsTable 1.3.6.1.4.1.300.110.4.2
The hdlc statistics table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HdlcStatsEntry

hdlcStatsEntry 1.3.6.1.4.1.300.110.4.2.1
An entry in the Hdlc statistics table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  HdlcStatsEntry  

hdlcPortIndex 1.3.6.1.4.1.300.110.4.2.1.1
Port Index
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

hdlcLinkStatusBadFCSc 1.3.6.1.4.1.300.110.4.2.1.2
Bad FCS
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

hdlcFramesAborted 1.3.6.1.4.1.300.110.4.2.1.3
Frame aborted
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

hdlcFramesNotAligned 1.3.6.1.4.1.300.110.4.2.1.4
Frame not aligned
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

hdlcOctetsRcv 1.3.6.1.4.1.300.110.4.2.1.5
Octets Received
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

hdlcPctsRcv 1.3.6.1.4.1.300.110.4.2.1.6
Packets Received
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

hdlcOctetsTrsmt 1.3.6.1.4.1.300.110.4.2.1.7
Octets Transmitted
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

hdlcPctsTrsmt 1.3.6.1.4.1.300.110.4.2.1.8
Packets Transmitted
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

miscStats 1.3.6.1.4.1.300.110.4.3
OBJECT IDENTIFIER    

miscprotocolPctsDumped 1.3.6.1.4.1.300.110.4.3.1
Rx packets with IF error on data Ethernet interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

miscnonroutablePcts 1.3.6.1.4.1.300.110.4.3.2
Rx packets non routable on data Ehternet interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

clrStats 1.3.6.1.4.1.300.110.4.4
OBJECT IDENTIFIER    

clearAllStats 1.3.6.1.4.1.300.110.4.4.1
clear all statistics
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER true(1)  

clearCur15Min 1.3.6.1.4.1.300.110.4.4.2
clear current 15 minutes statistics
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER true(1)  

clearCur24Hr 1.3.6.1.4.1.300.110.4.4.3
clear current 24 hours statistics
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER true(1)  

clearOld15Min 1.3.6.1.4.1.300.110.4.4.4
clear old 15 minutes statistics
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER true(1)  

clearOld24Hr 1.3.6.1.4.1.300.110.4.4.5
clear old 24 hours statistics
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER true(1)  

maintModTable 1.3.6.1.4.1.300.110.5.1
Table of all Module Status in the system
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MaintModEntry

maintModEntry 1.3.6.1.4.1.300.110.5.1.1
An entry in the maintModTable
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MaintModEntry  

maintModIndex 1.3.6.1.4.1.300.110.5.1.1.1
The module index
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER pp(1), ds1(2), enet(3), mpm(4)  

maintModStatus 1.3.6.1.4.1.300.110.5.1.1.2
Module actual status
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

maintOperstatus 1.3.6.1.4.1.300.110.5.1.1.3
Module Operational status
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

dl5400ModulesAppear 1
There is a module appeared in the device.
TRAP-TYPE    

dl5400ModulesDisappear 2
There is a module disappeared in the device.
TRAP-TYPE    

dl5400SelfTestFail 11
Self Test failed on the unit.
TRAP-TYPE    

dl5400RamTestFail 12
RAM Test failed on the unit.
TRAP-TYPE    

dl5400RomChecksumFail 13
ROM Checksum failed on the unit.
TRAP-TYPE    

dl5400FlashChecksumFail 14
Flash Checksum failed on the unit.
TRAP-TYPE    

dl5400TimeNotSet 15
The Unit's time is not set.
TRAP-TYPE    

dl5400UnitRestart 16
The Unit is resetting.
TRAP-TYPE    

dl5400LampTestStart 17
Lamp Test started.
TRAP-TYPE    

dl5400LampTestEnd 18
Lamp Test terminated.
TRAP-TYPE    

dl5400mgmtPOSTFail 19
Management POST failed.
TRAP-TYPE    

dl5400mgmtPOSTok 20
Management Port OK.
TRAP-TYPE    

dl5400FrontTemperatureHigh 21
The unit's front temperature is high.
TRAP-TYPE    

dl5400FrontTemperatureOK 22
The unit's front temperature is OK.
TRAP-TYPE    

dl5400BackTemperatureHigh 23
The unit's back temperature is high.
TRAP-TYPE    

dl5400BackTemperatureOK 24
The unit's back temperature is OK.
TRAP-TYPE    

dl5400ExternalMajorAlarmStart 25
The external major alarm input is active on the unit.
TRAP-TYPE    

dl5400ExternalMajorAlarmEnd 26
The external major alarm input is de-activated on the unit.
TRAP-TYPE    

dl5400ExternalMinorAlarmStart 27
The external minor alarm input is active on the unit.
TRAP-TYPE    

dl5400ExternalMinorAlarmEnd 28
The external minor alarm input is de-activated on the unit.
TRAP-TYPE    

dl5400ExternalStatusAlarmStart 29
The external status alarm input is active on the unit.
TRAP-TYPE    

dl5400ExternalStatusAlarmEnd 30
The external status alarm input is de-activated on the unit.
TRAP-TYPE    

dl5400PrimaryClockFail 31
Unit's primary clock has failed.
TRAP-TYPE    

dl5400PrimaryClockOk 32
Unit's primary clock is OK.
TRAP-TYPE    

dl5400SecondaryClockFail 33
Unit's Secondary clock has failed.
TRAP-TYPE    

dl5400SecondaryClockOk 34
Unit's Secondary clock is OK.
TRAP-TYPE    

dl5400ExternalClockFail 35
Unit's external clock has failed.
TRAP-TYPE    

dl5400ExternalClockOk 36
Unit's external clock is OK.
TRAP-TYPE    

dl5400Fan1FailAlarm 37
A fan 1 failed on the unit.
TRAP-TYPE    

dl5400Fan1Ok 38
A fan is ok on the unit.
TRAP-TYPE    

dl5400Fan2FailAlarm 39
A fan 2 failed on the unit.
TRAP-TYPE    

dl5400Fan2Ok 40
A fan 2 is ok on the unit.
TRAP-TYPE    

dl5400PSFanFailed 41
Power Supply Fan Failed on the unit.
TRAP-TYPE    

dl5400PSFanOK 42
Power Supply Fan OK on the unit.
TRAP-TYPE    

dl5400PktProcessorPostFail 43
Packet Processor POST Failed.
TRAP-TYPE    

dl5400PktProcessorPostOk 44
Packet Processor POST OK.
TRAP-TYPE    

dl5400PacketProcessorMissing 45
Packet Processor Missing.
TRAP-TYPE    

dl5400PacketProcessorOk 46
Packet Processor OK.
TRAP-TYPE    

dl5400VoltageExceeds 47
Voltage has exceeded allowed operating voltage range
TRAP-TYPE    

dl5400VoltageOk 48
Voltage is within allowed limits
TRAP-TYPE    

dl5400ModuleProcessorFail 49
Module Processor Failed
TRAP-TYPE    

dl5400ModuleProcessorOk 50
Module Processor OK.
TRAP-TYPE    

dl5400ModulesCfgMismatch 51
There is configuration mismatch between equipped modules.
TRAP-TYPE    

dl5400ModulesCfgMatch 52
There is no configuration mismatch between equipped modules.
TRAP-TYPE    

dl5400UsePriClkAlarm 53
Using primary clock source on the unit.
TRAP-TYPE    

dl5400UseSecClkAlarm 54
Using secondary clock source on the unit. Primary clock source failed on the unit.
TRAP-TYPE    

dl5400UseIntClkAlarm 55
Using internal clock source on the unit. Primary and secondary clock sources failed on the unit.
TRAP-TYPE    

dl5400UseRxClk1Alarm 56
Receive multiplexer synced to net 1.
TRAP-TYPE    

dl5400UseRxClk2Alarm 57
Receive multiplexer synced to net 2.
TRAP-TYPE    

dl5400UseRxClk3Alarm 58
Receive multiplexer synced to net 3.
TRAP-TYPE    

dl5400UseRxClk4Alarm 59
Receive multiplexer synced to net 4.
TRAP-TYPE    

dl5400UseRxClk5Alarm 60
Receive multiplexer synced to net 5.
TRAP-TYPE    

dl5400UseRxClk6Alarm 61
Receive multiplexer synced to net 6.
TRAP-TYPE    

dl5400UseRxClk7Alarm 62
Receive multiplexer synced to net 7.
TRAP-TYPE    

dl5400UseRxClk8Alarm 63
Receive multiplexer synced to net 8.
TRAP-TYPE    

dl5400MLpppPOSTFail 64
ML-PPP POST failed.
TRAP-TYPE    

dl5400MLpppPOSTok 65
ML-PPP Port OK.
TRAP-TYPE    

dl5400MLpppModuleMissing 66
ML-PPP Module is Missing
TRAP-TYPE    

dl5400MLpppModuleOK 67
ML-PPP Module is OK
TRAP-TYPE    


dl5400MLpppInsufficientLinksOk 69
Insufficient ML-PPP links alarm remitted.
TRAP-TYPE    

dl5400ModulesFail 70
There is a module failed in the device.
TRAP-TYPE    

dl5400ModulesUp 71
There is a module up in the device.
TRAP-TYPE    

dl5400LossOfSignalStart 100
Loss of Signal occured on the specified Network port.
TRAP-TYPE    

dl5400LossOfSignalEnd 101
Loss of Signal ended on the specified Network port.
TRAP-TYPE    

dl5400LossOfFrameStart 102
Loss of Frame ended on the specified Network port.
TRAP-TYPE    

dl5400LossOfFrameEnd 103
Loss of Frame ended on the specified Network port.
TRAP-TYPE    

dl5400AisStart 104
AIS Alarm started on the specified Network port.
TRAP-TYPE    

dl5400AisEnd 105
AIS Alarm started on the specified Network port.
TRAP-TYPE    

dl5400RaiStart 106
RAI Alarm(Yellow) received on the specified Network port.
TRAP-TYPE    

dl5400RaiEnd 107
RAI Alarm(Yellow) Ended on the specified Network port.
TRAP-TYPE    

dl5400netLineRemoteLoopbackStart 158
Network Line/Remote Loopback on specified Network port .
TRAP-TYPE    

dl5400netLineRemoteLoopbackEnd 159
Network Line/Remote Loopback ended on specified Network port .
TRAP-TYPE    

dl5400pppEchoTimeout 164
PPP Echo Timeout.
TRAP-TYPE    

dl5400pppEchoTimeoutRemit 165
PPP Echo Timeout Alarm Remitted.
TRAP-TYPE    

dl5400pppLineLoopbackStart 166
PPP Line Loopback Start.
TRAP-TYPE    

dl5400pppLineLoopbackEnd 167
PPP Line Loopback End.
TRAP-TYPE    

dl5400pppLinkFallbackStart 168
PPP Link FallbackStart.
TRAP-TYPE    

dl5400pppLinkFallbackEnd 169
PPP Link Fallback End.
TRAP-TYPE    

dl5400dteLocalLoopbackStart 170
Network DTE Local Loopback on specified Network port .
TRAP-TYPE    

dl5400dteLocalLoopbackEnd 171
Network DTE Local Loopback ended on specified Network port .
TRAP-TYPE    

dl5400dteRemoteLoopbackStart 172
Network DTE Remote Loopback on specified Network port .
TRAP-TYPE    

dl5400dteRemoteLoopbackEnd 173
Network DTE Remote Loopback ended on specified Network port .
TRAP-TYPE    

dl5400MLpppLinkDown 174
ML-PPP links down caused by ML-PPP Protocol Layer.
TRAP-TYPE    

dl5400MLpppLinkUp 175
ML-PPP links up caused by ML-PPP Protocol Layer.
TRAP-TYPE