DL5400-MIB DEFINITIONS ::= BEGIN -- Digital-Link Corporation definitions for DL5400 product agents -- Version : V1.0 08/28/1998 -- Comments : This MIB has not been officially released to the N.I.C. IMPORTS OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 enterprises, IpAddress, TimeTicks, Counter FROM RFC1155-SMI; -- The following information has been included from RFC1213. -- textual conventions DisplayString ::= OCTET STRING -- This data type is used to model textual information taken from -- NVT ASCII character set. By convention, objects with this syntax -- are declared as having SIZE (0..255) digital-link OBJECT IDENTIFIER ::= { enterprises 300 } dl5400 OBJECT IDENTIFIER ::= { digital-link 110 } configuration OBJECT IDENTIFIER ::= { dl5400 1 } alarms OBJECT IDENTIFIER ::= { dl5400 2 } events OBJECT IDENTIFIER ::= { dl5400 3 } statistics OBJECT IDENTIFIER ::= { dl5400 4 } maintenance OBJECT IDENTIFIER ::= { dl5400 5 } -- the Validation type is used for the variable that deletes -- an entry from a table, and ALWAYS takes at least these values: DL5400Validation ::= INTEGER { valid (1), invalid (2) } DL5400commBaudRate ::= INTEGER { bps1200 (1), bps2400 (2), bps4800 (3), bps9600 (4), bps19200 (5), bps38400 (6), bps57600 (7), bps115200 (8) } DL5400commParity ::= INTEGER { even (1), odd (2), none (3) } DL5400commStopBits ::= INTEGER { one (1), oneAndHalf (2), two (3) } DL5400commNumDataBits ::= INTEGER { seven (7), eight (8) } DL5400commFlowControl ::= INTEGER { xoffUntilXon (1), xoffUntilAny (2), hwFlowControl (3), none (4) } TODYear ::= INTEGER (0..9999) TODMonth ::= INTEGER (1..12) TODDay ::= INTEGER (1..31) TODHour ::= INTEGER (0..23) TODMinute ::= INTEGER (0..59) TODSecond ::= INTEGER (0..59) DL5400CardId ::= INTEGER { mpm (1), pp (2), enet (3), ds1 (4) } DL5400PortId ::= INTEGER { dte (1), nmsEthernet (2), comm1 (3), comm2 (4), net1 (5), net2 (6), net3 (7), net4 (8), net5 (9), net6 (10), net7 (11), net8 (12) } DL5400TxClkSrc ::= INTEGER { internalClock (1), externalClock (2), rcvrdTiming (3), autoTiming (4) } DL5400Event ::= INTEGER { ev-mod-appear (1) , ev-mod-disappear (2) , ev-system-reset (3) , ev-system-initialized (4) , ev-timeofday-changed (5) , ev-admin-isnr (6) , ev-admin-oos (7) , ev-admin-oosmt (8) , ev-cuisession-inactivitytimeout (9) , ev-clkref-configchanged (10) , ev-selftest-fail(11) , ev-ram-test-fail(12) , ev-rom-checksum-fail(13) , ev-flash-checksum-fail(14) , ev-time-not-set(15) , ev-unit-restart(16) , ev-lamptest-start(17) , ev-lamptest-end(18) , ev-mgmt-post-fail(19) , ev-mgmt-post-fail-remit(20) , ev-front-high-temperature(21) , ev-front-high-temperature-remit(22) , ev-back-high-temperature(23) , ev-back-high-temperature-remit(24) , ev-external-major-alarm-input(25) , ev-external-major-alarm-input-end(26) , ev-external-minor-alarm-input(27) , ev-external-minor-alarm-input-end(28) , ev-external-status-alarm-input(29) , ev-external-status-alarm-input-end(30) , ev-primary-clk-fail(31) , ev-primary-clk-ok(32) , ev-secondary-clk-fail(33) , ev-secondary-clk-ok(34) , ev-ext-clk-fail(35) , ev-ext-clk-ok(36) , ev-fan1-fail(37) , ev-fan1-ok(38) , ev-fan2-fail(39) , ev-fan2-ok(40) , ev-ps-fan-fail(41) , ev-ps-fan-ok(42) , ev-packet-processor-post-fail(43) , ev-packet-processor-post-ok(44) , ev-packet-processor-missing(45) , ev-packet-processor-ok(46) , ev-voltage-exceeds(47) , ev-voltage-ok(48) , ev-module-processor-fail(49) , ev-module-processor-ok(50) , ev-mod-cfg-mismatch (51) , ev-mod-cfg-match (52) , ev-use-primary-clk(53) , ev-use-secondary-clk(54) , ev-use-internal-clk(55) , ev-use-rx-clk1(56) , ev-use-rx-clk2(57) , ev-use-rx-clk3(58) , ev-use-rx-clk4(59) , ev-use-rx-clk5(60) , ev-use-rx-clk6(61) , ev-use-rx-clk7(62) , ev-use-rx-clk8(63) , ev-mlppp-post-fail(64) , ev-mlppp-post-fail-remit(65) , ev-mlppp-module-missing(66) , ev-mlppp-module-ok(67) , ev-mlppp-insufficient-links(68) , ev-mlppp-insufficient-links-remit(69) , ev-mod-fail (70) , ev-mod-up (71) , ev-mod-no-resp (72) , ev-mod-hello (73) , ev-mod-init-fail (74) , ev-mod-init-ok (75) , ev-mod-some-ports-failed (76) , ev-mod-some-ports-ok (77) , ev-mod-all-ports-failed (78) , ev-mod-all-ports-ok (79) , ev-lost-signal(100) , ev-lost-signal-remit(101) , ev-lof(102) , ev-lof-remit(103) , ev-ais(104) , ev-ais-remit(105) , ev-rai(106) , ev-rai-remit(107) , ev-red-alarm(108) , ev-red-alarm-remit(109) , ev-exceeded-cv-consec-sec(110) , ev-exceeded-cv-consec-sec-remit(111) , ev-exceeded-ses-consec-sec(112) , ev-exceeded-ses-consec-sec-remit(113) , ev-exceeded-uas-consec-sec(114) , ev-exceeded-uas-consec-sec-remit(115) , ev-exceeded-pcv-15min-minor-threshold(116) , ev-exceeded-pcv-15min-minor-threshold-remit(117) , ev-exceeded-pcv-15min-major-threshold(118) , ev-exceeded-pcv-15min-major-threshold-remit(119) , ev-exceeded-es-15min-minor-threshold(120) , ev-exceeded-es-15min-minor-threshold-remit(121) , ev-exceeded-es-15min-major-threshold(122) , ev-exceeded-es-15min-major-threshold-remit(123) , ev-exceeded-ses-15min-minor-threshold(124) , ev-exceeded-ses-15min-minor-threshold-remit(125) , ev-exceeded-ses-15min-major-threshold(126) , ev-exceeded-ses-15min-major-threshold-remit(127) , ev-exceeded-sas-15min-minor-threshold(128) , ev-exceeded-sas-15min-minor-threshold-remit(129) , ev-exceeded-sas-15min-major-threshold(130) , ev-exceeded-sas-15min-major-threshold-remit(131) , ev-exceeded-uas-15min-minor-threshold(132) , ev-exceeded-uas-15min-minor-threshold-remit(133) , ev-exceeded-uas-15min-major-threshold(134) , ev-exceeded-uas-15min-major-threshold-remit(135) , ev-exceeded-pcv-24hr-minor-threshold(136) , ev-exceeded-pcv-24hr-minor-threshold-remit(137) , ev-exceeded-pcv-24hr-major-threshold(138) , ev-exceeded-pcv-24hr-major-threshold-remit(139) , ev-exceeded-es-24hr-minor-threshold(140) , ev-exceeded-es-24hr-minor-threshold-remit(141) , ev-exceeded-es-24hr-major-threshold(142) , ev-exceeded-es-24hr-major-threshold-remit(143) , ev-exceeded-ses-24hr-minor-threshold(144) , ev-exceeded-ses-24hr-minor-threshold-remit(145) , ev-exceeded-ses-24hr-major-threshold(146) , ev-exceeded-ses-24hr-major-threshold-remit(147) , ev-exceeded-sas-24hr-minor-threshold(148) , ev-exceeded-sas-24hr-minor-threshold-remit(149) , ev-exceeded-sas-24hr-major-threshold(150) , ev-exceeded-sas-24hr-major-threshold-remit(151) , ev-exceeded-uas-24hr-minor-threshold(152) , ev-exceeded-uas-24hr-minor-threshold-remit(153) , ev-exceeded-uas-24hr-major-threshold(154) , ev-exceeded-uas-24hr-major-threshold-remit(155) , ev-net-local-loopback-start(156) , ev-net-local-loopback-end(157) , ev-net-remote-loopback-start(158) , ev-net-remote-loopback-end(159) , ev-net-payload-loopback-start(160) , ev-net-payload-loopback-end(161) , ev-net-BERT-start(162) , ev-net-BERT-end(163) , ev-ppp-echo-timeout(164) , ev-ppp-echo-timeout-remit(165) , ev-ppp-loopback-line(166) , ev-ppp-loopback-line-remit(167) , ev-ppp-link-fallback(168) , ev-ppp-link-fallback-remit(169) , ev-dte-local-loopback-start(170) , ev-dte-local-loopback-end(171) , ev-dte-remote-loopback-start(172) , ev-dte-remote-loopback-end(173) , ev-mlppp-link-down(174) , ev-mlppp-link-up(175) } -- ============================================================================= -- Unit Level Configuration -- ============================================================================= unitLevelConfig OBJECT IDENTIFIER ::= { configuration 1 } unitSerialNum OBJECT-TYPE SYNTAX DisplayString (SIZE(0..20)) ACCESS read-only STATUS mandatory DESCRIPTION "An ID that uniquely and globally identifies the unit. A Serial Number must consist of printable ASCII characters 0x20..0x7E." ::= { unitLevelConfig 1 } unitName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) ACCESS read-write STATUS mandatory DESCRIPTION "A descriptive name that identifies the DL5400 unit. Use of this parameter is optional, but recommended to aid management." ::= { unitLevelConfig 2 } unitHwRev OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-only STATUS mandatory DESCRIPTION "The DL5400 hardware revision." ::= { unitLevelConfig 3 } unitSwRev OBJECT-TYPE SYNTAX DisplayString (SIZE (1..7)) ACCESS read-only STATUS mandatory DESCRIPTION "The DL5400 software revision." ::= { unitLevelConfig 4 } unitMibRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) ACCESS read-only STATUS mandatory DESCRIPTION "The DL5400 MIB revision." ::= { unitLevelConfig 5 } unitFrontPnl OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This feature enables (ON) or disables (OFF) the users ability to make changes in the configuration or run tests from the front panel display and buttons." ::= { unitLevelConfig 6 } unitDateYear OBJECT-TYPE SYNTAX TODYear ACCESS read-write STATUS mandatory DESCRIPTION "The DL5400's date: Year." ::= { unitLevelConfig 7 } unitDateMonth OBJECT-TYPE SYNTAX TODMonth ACCESS read-write STATUS mandatory DESCRIPTION "The DL5400's date: Month." ::= { unitLevelConfig 8 } unitDateDay OBJECT-TYPE SYNTAX TODDay ACCESS read-write STATUS mandatory DESCRIPTION "The DL5400's date: Day." ::= { unitLevelConfig 9 } unitTimeHour OBJECT-TYPE SYNTAX TODHour ACCESS read-write STATUS mandatory DESCRIPTION "The DL5400's time: Hour." ::= { unitLevelConfig 10 } unitTimeMinute OBJECT-TYPE SYNTAX TODMinute ACCESS read-write STATUS mandatory DESCRIPTION "The DL5400's time: Minute." ::= { unitLevelConfig 11 } unitTimeSecond OBJECT-TYPE SYNTAX TODSecond ACCESS read-write STATUS mandatory DESCRIPTION "The DL5400's time: Second." ::= { unitLevelConfig 12 } unitTimezone OBJECT-TYPE SYNTAX INTEGER{ gmtTimezone ( 1), g01Timezone ( 2), g02Timezone ( 3), g03Timezone ( 4), g04Timezone ( 5), estTimezone ( 6), cstTimezone ( 7), mstTimezone ( 8), pstTimezone ( 9), astTimezone (10), hstTimezone (11), g11Timezone (12), g12Timezone (13), g13Timezone (14), g14Timezone (15), g15Timezone (16), g16Timezone (17), g17Timezone (18), g18Timezone (19), g19Timezone (20), g20Timezone (21), g21Timezone (22), g22Timezone (23), g23Timezone (24) } ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to indicate the timezone associated with the time of day that exists on DL5400 System. The enumerated values are defined as hours west of Greenwhich, for example, g01Timezone represents the time zone which is 1 hour west of Greenwhich. " DEFVAL { gmtTimezone } ::= { unitLevelConfig 13 } unitLedStatus OBJECT-TYPE SYNTAX INTEGER { off (1), green (2), blink-Green (3), blink-Amber (4), solid-Amber (5), red (6), blink-Red (7) } ACCESS read-only STATUS mandatory DESCRIPTION " The defined values have the following description Off - The unit is not equipped or is provision in an out of Service state Green - No alarms, status or test conditions exists for the unit Blink Amber - Test conditions are present in the unit Solid Amber - A minor alarm condition persists in the unit or on some interface of the unit, or the unit is powering up. Red - An Alarm condition persists in the unit or on some interface of the unit Blink-Green - reserved Blink-Red - reserved " ::= { unitLevelConfig 14 } unitTimeStamp OBJECT-TYPE SYNTAX DisplayString (SIZE(1..20)) ACCESS read-only STATUS mandatory DESCRIPTION "Time Stamp on the unit of format MM/DD/YYYY HH:MM:SS This will be sent as a varbind along with all the traps to NMS manager" ::= { unitLevelConfig 15 } unitModelType OBJECT-TYPE SYNTAX INTEGER { ml-pppNxDs1Enet (1) } ACCESS read-only STATUS mandatory DESCRIPTION "The unit model type " ::= { unitLevelConfig 16 } unitRouteMode OBJECT-TYPE SYNTAX INTEGER { staticIp (1), fastForward (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Unit Route Mode" ::= { unitLevelConfig 17 } -- ========================================================================= -- Telnet Configuration Parameters -- ========================================================================= unitTelnetConfig OBJECT IDENTIFIER ::= { configuration 2 } unitTelnetIdleTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to indicate number of minutes of inactivity required before setting the telnet access point to auto-logoff. " DEFVAL { 0 } ::= { unitTelnetConfig 1 } -- ============================================================================= -- DTE Interface Configuration -- ============================================================================= unitDteEnetCfg OBJECT IDENTIFIER ::= { configuration 3 } dteEnetTable OBJECT-TYPE SYNTAX SEQUENCE OF DteEnetEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of all Dte Ethernet ports in the system " ::= {unitDteEnetCfg 1} dteEnetEntry OBJECT-TYPE SYNTAX DteEnetEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the dteEnetTable " INDEX { dteEnetIndex } ::= {dteEnetTable 1} DteEnetEntry ::= SEQUENCE { dteEnetIndex INTEGER, dteEnetIpAddress IpAddress, dteEnetSubnetMask IpAddress, dteEnetMacAddress OCTET STRING, dteEnetProtocol INTEGER, dteEnetOper INTEGER, dteEnetMode INTEGER, dteEnetOperStatus DisplayString, dteEnetModeStatus DisplayString } dteEnetIndex OBJECT-TYPE SYNTAX INTEGER { dte1 (1) } ACCESS read-only STATUS mandatory DESCRIPTION " The dteEnet port index " ::= {dteEnetEntry 1} dteEnetIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address assigned to the DTE port of the DL5400." ::= {dteEnetEntry 2} dteEnetSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP Subnet mask assigned to the DTE port of the DL5400." ::= {dteEnetEntry 3} dteEnetMacAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) ACCESS read-only STATUS mandatory DESCRIPTION "Ethernet MAC address of this dte port" ::= {dteEnetEntry 4} dteEnetProtocol OBJECT-TYPE SYNTAX INTEGER { ethernet (1), ieee8023 (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Ethernet protocol used by the DL5400. dix is also called Ethernet-II." ::= {dteEnetEntry 5} dteEnetOper OBJECT-TYPE SYNTAX INTEGER { autodetect (1), tenMb (2), hundredMb (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Ethernet operation used by the DL5400." ::= {dteEnetEntry 6} dteEnetMode OBJECT-TYPE SYNTAX INTEGER { autodetect (1), halfduplex (2), fullduplex (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Ethernet mode used by the DL5400." ::= {dteEnetEntry 7} dteEnetOperStatus OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Ethernet operation status" ::= {dteEnetEntry 8} dteEnetModeStatus OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Ethernet Mode status" ::= {dteEnetEntry 9} -- ============================================================================= -- Management Port Ethernet Common Configuration. Currently not supported 5-10-00 -- ============================================================================= -- mgmtEnetConfig OBJECT IDENTIFIER ::= { configuration 4 } -- mgmtEnetIpAddress OBJECT-TYPE -- SYNTAX IpAddress -- ACCESS read-write -- STATUS mandatory -- DESCRIPTION -- "IP address assigned to the Management Ethernet port of the DL5400." -- ::= { mgmtEnetConfig 1 } -- mgmtEnetSubnetMask OBJECT-TYPE -- SYNTAX IpAddress -- ACCESS read-write -- STATUS mandatory -- DESCRIPTION -- "IP Subnet mask assigned to the Management Ethernet port of the DL5400." -- ::= { mgmtEnetConfig 2 } -- mgmtEnetDefaultGateway OBJECT-TYPE -- SYNTAX IpAddress -- ACCESS read-write -- STATUS mandatory -- DESCRIPTION -- "IP address of the default gateway attached to the DL5400. -- The default gateway must be on the same Ethernet segment -- as the Dl5400." -- ::= { mgmtEnetConfig 3 } -- mgmtEnetMacAddress OBJECT-TYPE -- SYNTAX OCTET STRING (SIZE(6)) -- ACCESS read-only -- STATUS mandatory -- DESCRIPTION -- "Ethernet MAC address of the DL5400." -- ::= { mgmtEnetConfig 4 } -- ============================================================================= -- Comm1 Configuration -- ============================================================================= comm1SerialConfig OBJECT IDENTIFIER ::= { configuration 5 } comm1SerialPortState OBJECT-TYPE SYNTAX INTEGER{ disabled (1), enabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to enable or disable port." DEFVAL { enabled } ::= { comm1SerialConfig 1 } comm1SerialBaudRate OBJECT-TYPE SYNTAX DL5400commBaudRate ACCESS read-write STATUS mandatory DESCRIPTION "COMM 1 Baud Rate." ::= { comm1SerialConfig 2 } comm1SerialBitsPerWord OBJECT-TYPE SYNTAX DL5400commNumDataBits ACCESS read-write STATUS mandatory DESCRIPTION "COMM 1 Bits Per Word." ::= { comm1SerialConfig 3 } comm1SerialStopBits OBJECT-TYPE SYNTAX DL5400commStopBits ACCESS read-write STATUS mandatory DESCRIPTION "COMM 1 Stop Bits." ::= { comm1SerialConfig 4 } comm1SerialParity OBJECT-TYPE SYNTAX DL5400commParity ACCESS read-write STATUS mandatory DESCRIPTION "COMM 1 Parity." ::= { comm1SerialConfig 5 } comm1SerialFlowControl OBJECT-TYPE SYNTAX DL5400commFlowControl ACCESS read-write STATUS mandatory DESCRIPTION "COMM 1 Flow Control." ::= { comm1SerialConfig 6 } comm1SerialLogoutOnLos OBJECT-TYPE SYNTAX INTEGER{ disabled (1), enabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to enable or disable auto-logoff on loss of DSR." DEFVAL { enabled } ::= { comm1SerialConfig 7 } comm1SerialIdleTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to indicate number of minutes of inactivity required before setting this serial access point to auto-logoff. " DEFVAL { 0 } ::= { comm1SerialConfig 8 } -- ============================================================================= -- Comm2 Configuration -- ============================================================================= comm2SerialConfig OBJECT IDENTIFIER ::= { configuration 6 } comm2SerialPortState OBJECT-TYPE SYNTAX INTEGER{ disabled (1), enabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to enable or disable port." DEFVAL { enabled } ::= { comm2SerialConfig 1 } comm2SerialBaudRate OBJECT-TYPE SYNTAX DL5400commBaudRate ACCESS read-write STATUS mandatory DESCRIPTION "COMM 2 Baud Rate." ::= { comm2SerialConfig 2 } comm2SerialBitsPerWord OBJECT-TYPE SYNTAX DL5400commNumDataBits ACCESS read-write STATUS mandatory DESCRIPTION "COMM 2 Bits Per Word." ::= { comm2SerialConfig 3 } comm2SerialStopBits OBJECT-TYPE SYNTAX DL5400commStopBits ACCESS read-write STATUS mandatory DESCRIPTION "COMM 2 Stop Bits." ::= { comm2SerialConfig 4 } comm2SerialParity OBJECT-TYPE SYNTAX DL5400commParity ACCESS read-write STATUS mandatory DESCRIPTION "COMM 2 Parity." ::= { comm2SerialConfig 5 } comm2SerialFlowControl OBJECT-TYPE SYNTAX DL5400commFlowControl ACCESS read-write STATUS mandatory DESCRIPTION "COMM 2 Flow Control. HwFlowControl option is not applicable for multidrop serial port when in MultiDrop mode" ::= { comm2SerialConfig 6 } comm2SerialLogoutOnLos OBJECT-TYPE SYNTAX INTEGER{ disabled (1), enabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to enable or disable auto-logoff on loss of DSR." DEFVAL { enabled } ::= { comm2SerialConfig 7 } comm2SerialIdleTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " This object is used to indicate number of minutes of inactivity required before setting this serial access point to auto-logoff. " DEFVAL { 0 } ::= { comm2SerialConfig 8 } comm2InMDmode OBJECT-TYPE SYNTAX INTEGER{ disabled (1), enabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION " This object indicates if this serial port is in multidrop mode or not. " ::= { comm2SerialConfig 9 } comm2InMDId OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Identifies the multidrop session " DEFVAL { "0" } ::= { comm2SerialConfig 10 } -- ============================================================================= -- NET Configuration -- ============================================================================= netConfig OBJECT IDENTIFIER ::= { configuration 7 } netPriTxClk OBJECT-TYPE SYNTAX DL5400TxClkSrc ACCESS read-write STATUS mandatory DESCRIPTION "The primary transmit clock source for DL5400." ::= { netConfig 1 } netPriLoopPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The primary loop port clock source for DL5400." ::= { netConfig 2 } netSecTxClk OBJECT-TYPE SYNTAX DL5400TxClkSrc ACCESS read-write STATUS mandatory DESCRIPTION "The secondary transmit clock source for DL5400." ::= { netConfig 3 } netSecLoopPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The secondary loop port clock source for DL5400." ::= { netConfig 4 } netExtClkFrequency OBJECT-TYPE SYNTAX INTEGER { freq8kHZ (1), freq1544kHZ (2) } ACCESS read-write STATUS mandatory DESCRIPTION "The defined parameters are the external clock frequencies. The user must provision what frequency is to be used" ::= { netConfig 5 } netPriStatus OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Primary clock operation status" ::= { netConfig 6 } netSecStatus OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Secondary clock operation status" ::= { netConfig 7 } netActiveStatus OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Active clock operation status" ::= { netConfig 8 } netSuppressYeldet OBJECT-TYPE SYNTAX INTEGER { suppressYelDet(1), allowYelDet(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This enables or disables the suppression of Yellow Alarm (RAI) detection. Applicable in SF Framing" ::= { netConfig 9 } netLineType OBJECT-TYPE SYNTAX INTEGER{ t1 (1), e1 (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Tells if this is a T1 or E1 device" ::= {netConfig 10 } -- =========================================================================== -- Network Port Configuration -- =========================================================================== netPortTable OBJECT-TYPE SYNTAX SEQUENCE OF NetPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Table of all network port in the system. " ::= { netConfig 11 } netPortEntry OBJECT-TYPE SYNTAX NetPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Net Port Table" INDEX { netPortIndex } ::= { netPortTable 1 } NetPortEntry ::= SEQUENCE { netPortIndex INTEGER, netAdmin INTEGER, netFramingFormat INTEGER, netLineCode INTEGER, netLBO INTEGER, netEGL INTEGER, netFDL INTEGER, netSetCode INTEGER, netClock INTEGER, netFrameStatus DisplayString, netFrameUpTime TimeTicks } netPortIndex OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "The network port index." ::= { netPortEntry 1 } netAdmin OBJECT-TYPE SYNTAX INTEGER { is(1), oos(2), oos-mt(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Tells the Net DS1 Admin state" ::= { netPortEntry 2 } netFramingFormat OBJECT-TYPE SYNTAX INTEGER { esf (2), d4 (3) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable describes the Framing Format option for the network port." ::= { netPortEntry 3 } netLineCode OBJECT-TYPE SYNTAX INTEGER { b8zs (2), ami (5) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable describes the Line Code option for the network port." ::= { netPortEntry 4 } netLBO OBJECT-TYPE SYNTAX INTEGER { ft0To133 (3), ft133To266 (4), ft266To399 (5), ft399To533 (6), ft533To655 (7), lbo-0dB (8), lbo-7p5dB (9), lbo-15dB (10), lbo-22p5dB (11) } ACCESS read-write STATUS mandatory DESCRIPTION "This selects the line build out value in dBs and applies to CSU/DSU mode only." ::= { netPortEntry 5 } netEGL OBJECT-TYPE SYNTAX INTEGER { egl-36dB(1), egl-30dB(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This selects the equalizer gain limit in dBs and applies to CSU mode only." ::= { netPortEntry 6 } netFDL OBJECT-TYPE SYNTAX INTEGER { none (1), ansi (2), att (3), both (4) } ACCESS read-write STATUS mandatory DESCRIPTION "'other' indicates that a protocol other than one following is used. 'dsx1Ansi-T1-403' refers to the FDL exchange recommended by ANSI. 'dsx1Att-54016' refers to ESF FDL exchanges. 'dsx1Fdl-none' indicates that the device does not use the FDL." ::= { netPortEntry 7 } netSetCode OBJECT-TYPE SYNTAX INTEGER { no (1), yes(2) } ACCESS read-write STATUS mandatory DESCRIPTION "enabled or disabled setCode feature." ::= { netPortEntry 8 } netClock OBJECT-TYPE SYNTAX INTEGER { loopTiming(1), sysTiming(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This selects the source of Transmit clock." ::= { netPortEntry 9 } netFrameStatus OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Framing Operational State." ::= { netPortEntry 10 } netFrameUpTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Tells the Framing UpTime." ::= { netPortEntry 11 } -- ============================================================================ -- SNMP Configuration items -- ============================================================================ unitSnmpConfig OBJECT IDENTIFIER ::= { configuration 8 } unitSnmpTrapAddrTable OBJECT-TYPE SYNTAX SEQUENCE OF UnitSnmpTrapAddrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A list of IP addresses of the management stations along with information on how to direct a trap to that addresss" ::= { unitSnmpConfig 1} unitSnmpTrapAddrEntry OBJECT-TYPE SYNTAX UnitSnmpTrapAddrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Snmp trap address table" INDEX { unitSnmpTrapHostAddr } ::= {unitSnmpTrapAddrTable 1} UnitSnmpTrapAddrEntry ::= SEQUENCE { unitSnmpTrapHostAddr IpAddress, unitSnmpTrapDirection INTEGER } unitSnmpTrapHostAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the IP address of the management station to which this unit sends traps." ::= { unitSnmpTrapAddrEntry 1 } unitSnmpTrapDirection OBJECT-TYPE SYNTAX INTEGER { disabled (1), inBand (2), outBand (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the way the trap is to be sent to the host" ::= { unitSnmpTrapAddrEntry 2 } unitSnmpTrapDevState OBJECT-TYPE SYNTAX INTEGER { forward (1), block (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies whether to forward or block SNMP traps on device." ::= { unitSnmpConfig 2 } unitSnmpTrapCommunity OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the Community Name of the management station to which this unit sends traps." ::= { unitSnmpConfig 3 } -- ============================================================================= -- PPP Configuration -- ============================================================================= unitPPPConfig OBJECT IDENTIFIER ::= { configuration 9 } --- PPP Port table, defines objects for PPP port initialization and status information pppPortTable OBJECT-TYPE SYNTAX SEQUENCE OF PPPPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Table of all network ports in the system. " ::= { unitPPPConfig 1 } pppPortEntry OBJECT-TYPE SYNTAX PPPPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the PPP Port table" INDEX { pppPortIndex } ::= {pppPortTable 1} PPPPortEntry ::= SEQUENCE { pppPortIndex INTEGER, pppPortInitialMRU INTEGER, pppPortMagicNumber INTEGER, pppPortFcsSize INTEGER, pppPortRestore INTEGER } pppPortIndex OBJECT-TYPE SYNTAX INTEGER{ net1 (1), net2 (2), net3 (3), net4 (4), net5 (5), net6 (6), net7 (7), net8 (8) } ACCESS read-only STATUS mandatory DESCRIPTION "Port number of the Net port." ::= { pppPortEntry 1 } pppPortInitialMRU OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The initial Maximum Receive Unit (MRU) that the local PPP entity will advertise to the remote entity. If the value of this variable is 0 then the local PPP entity will not advertise any MRU to the remote entity and the default MRU will be assumed. Changing this object will have effect when the link is next restarted." ::= { pppPortEntry 2 } pppPortMagicNumber OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } ACCESS read-write STATUS mandatory DESCRIPTION "If true(2) then the local node will attempt to perform Magic Number negotiation with the remote node. If false(1) then this negotiation is not performed. In any event, the local node will comply with any magic number negotiations attempted by the remote node, per the PPP specification. Changing this object will have effect when the link is next restarted." ::= { pppPortEntry 3 } pppPortFcsSize OBJECT-TYPE SYNTAX INTEGER { size16bits(1), size32bits(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The size of the FCS, in bits, the local node will attempt to negotiate for use with the remote node. Regardless of the value of this object, the local node will comply with any FCS size negotiations initiated by the remote node, per the PPP specification. Changing this object will have effect when the link is next restarted." ::= { pppPortEntry 4 } pppPortRestore OBJECT-TYPE SYNTAX INTEGER { auto (1), manual (2) } ACCESS read-write STATUS mandatory DESCRIPTION "PPP port restore mode, auto or manual." ::= { pppPortEntry 5 } -- ============================================================================= -- ML-PPP Parameters -- ============================================================================= unitMLPPPConfig OBJECT IDENTIFIER ::= { unitPPPConfig 2 } mlPPPIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP Address assigned to the ML-PPP port of DL5400." ::= { unitMLPPPConfig 1 } mlPPPSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP Subnet mask assigned to the ML-PPP link of DL5400." ::= { unitMLPPPConfig 2 } mlPPPNumberedInterface OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Numbered Interface enabled or disabled." ::= { unitMLPPPConfig 3 } mlPPPMRRU OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Maximum Received Reconstructed Unit of ML-PPP." ::= { unitMLPPPConfig 4 } mlPPPBundleStatus OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Tells the current bundle status" ::= {unitMLPPPConfig 5 } mlPPPBundleUpTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The time (in hundredths of a second) since the bundle is up." ::= { unitMLPPPConfig 6 } mlPPPIPCPState OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The current state of IPCP." ::= { unitMLPPPConfig 7 } mlPPPPortTable OBJECT-TYPE SYNTAX SEQUENCE OF MLPPPPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Table of all mlppp port in the system. " ::= { unitPPPConfig 3 } mlPPPPortEntry OBJECT-TYPE SYNTAX MLPPPPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mlppp Port Table" INDEX { mlPPPPortIndex } ::= { mlPPPPortTable 1 } MLPPPPortEntry ::= SEQUENCE { mlPPPPortIndex INTEGER, mlPPPAdmin INTEGER, mlPPPStatus DisplayString, mlPPPUpTime TimeTicks, mlPPPLCPState DisplayString } mlPPPPortIndex OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "The network port index." ::= { mlPPPPortEntry 1 } mlPPPAdmin OBJECT-TYPE SYNTAX INTEGER { is(1), oos(2), oos-mt(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Tells the MLPPP Admin State." ::= { mlPPPPortEntry 2 } mlPPPStatus OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Tells the MLPPP Operational State." ::= { mlPPPPortEntry 3 } mlPPPUpTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The time (in hundredths of a second) since the MLPPP is up." ::= { mlPPPPortEntry 4 } mlPPPLCPState OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Tells the LCP Operational State." ::= { mlPPPPortEntry 5 } -- ============================================================================= -- Router Configuration -- ============================================================================= unitRouterConfig OBJECT IDENTIFIER ::= { configuration 10 } unitStaticRoutingTable OBJECT-TYPE SYNTAX SEQUENCE OF StaticRoutingEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Table of all static routing entries in the system. " ::= { unitRouterConfig 1 } staticRoutingEntry OBJECT-TYPE SYNTAX StaticRoutingEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " An entry in the static routing table. " INDEX { routeDestination } ::= { unitStaticRoutingTable 1 } StaticRoutingEntry ::= SEQUENCE { routeDestination IpAddress, routeNetworkMask IpAddress, routeNextHopAddress IpAddress, routeMetric INTEGER, routeDirection INTEGER, routeStatus DL5400Validation } routeDestination OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Destination of the static route." ::= { staticRoutingEntry 1 } routeNetworkMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Network Mask" ::= { staticRoutingEntry 2 } routeNextHopAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Address of the next hop router. The next hop router must be on the same local network as DL5400" ::= { staticRoutingEntry 3 } routeMetric OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Number of hops between DL5400 and the destination." ::= { staticRoutingEntry 4 } routeDirection OBJECT-TYPE SYNTAX INTEGER { wan(1), num(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Direction of the Route, Network(NUM) or WAN." ::= { staticRoutingEntry 5 } routeStatus OBJECT-TYPE SYNTAX DL5400Validation ACCESS read-write STATUS mandatory DESCRIPTION "Writing invalid has the effect of deleting this interface." ::= { staticRoutingEntry 6 } unitArpConfig OBJECT IDENTIFIER ::= { configuration 11 } unitClearArpTable OBJECT-TYPE SYNTAX INTEGER { true(1) } ACCESS read-write STATUS mandatory DESCRIPTION " Clear all arp entries in the system. " ::= { unitArpConfig 1 } unitArpTable OBJECT-TYPE SYNTAX SEQUENCE OF UnitArpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Table of all arp entries in the system. " ::= { unitArpConfig 2 } unitArpEntry OBJECT-TYPE SYNTAX UnitArpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " An entry in the arp table. " INDEX { arpEntryNum } ::= { unitArpTable 1 } UnitArpEntry ::= SEQUENCE { arpEntryNum INTEGER, arpIPAddress IpAddress, arpMACAddress OCTET STRING, arpPortNum INTEGER } arpEntryNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Entry Number in the arp table." ::= { unitArpEntry 1 } arpIPAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Entry IpAddress in the arp table." ::= { unitArpEntry 2 } arpMACAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) ACCESS read-only STATUS mandatory DESCRIPTION "Entry MAC address in the arp table." ::= { unitArpEntry 3 } arpPortNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Entry Port Number in the arp table." ::= { unitArpEntry 4 } -- ============================================================================= -- Unit Alarm Status -- ============================================================================= unitAlarmConfig OBJECT IDENTIFIER ::= { alarms 1 } unitAlarmStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF UnitAlarmStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Unit Level alarms and status table." ::= { unitAlarmConfig 1 } unitAlarmStatusEntry OBJECT-TYPE SYNTAX UnitAlarmStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An Entry in the unit Alarms Table." INDEX { unitAlarmIndex } ::= { unitAlarmStatusTable 1 } UnitAlarmStatusEntry ::= SEQUENCE { unitAlarmIndex INTEGER, unitAlarmSeverity INTEGER, unitAlarmType DL5400Event, unitAlarmOriginCardNum DL5400CardId, unitAlarmOriginPortNum DL5400PortId } unitAlarmIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "An index value that uniquely identifies a Unit Level alarm entry." ::= { unitAlarmStatusEntry 1 } unitAlarmSeverity OBJECT-TYPE SYNTAX INTEGER { status(1), minor(2), major(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the severity of the alarm, or may indicate that the data is status only." ::= { unitAlarmStatusEntry 2 } unitAlarmType OBJECT-TYPE SYNTAX DL5400Event ACCESS read-only STATUS mandatory DESCRIPTION "This parameter is the code for the alarm or status type. This code is used to index into an array of text strings to present a message to the human operator." ::= { unitAlarmStatusEntry 3 } unitAlarmOriginCardNum OBJECT-TYPE SYNTAX DL5400CardId ACCESS read-only STATUS mandatory DESCRIPTION "The card type of the device originating the event." ::= { unitAlarmStatusEntry 4 } unitAlarmOriginPortNum OBJECT-TYPE SYNTAX DL5400PortId ACCESS read-only STATUS mandatory DESCRIPTION "The port number of the device originating the event." ::= { unitAlarmStatusEntry 5 } -- ============================================================================ -- Unit Event History -- ============================================================================ unitEventTable OBJECT-TYPE SYNTAX SEQUENCE OF UnitEventEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Unit Level event history table." ::= { events 1 } unitEventEntry OBJECT-TYPE SYNTAX UnitEventEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Unit Level event history table." INDEX { unitEventIndex } ::= { unitEventTable 1 } UnitEventEntry ::= SEQUENCE { unitEventIndex INTEGER, unitEventSeverity INTEGER, unitEventHour TODHour, unitEventMinute TODMinute, unitEventSecond TODSecond, unitEventMonth TODMonth, unitEventDay TODDay, unitEventYear TODYear, unitEventOriginCardNum DL5400CardId, unitEventOriginPortNum DL5400PortId, unitEventType DL5400Event } unitEventIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies a Unit Level event entry." ::= { unitEventEntry 1 } unitEventSeverity OBJECT-TYPE SYNTAX INTEGER { status (1), minor (2), major (3), clear (4), information (5) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates whether an entry is status-only or the severity of an alarm entry." ::= { unitEventEntry 2 } unitEventHour OBJECT-TYPE SYNTAX TODHour ACCESS read-only STATUS mandatory DESCRIPTION "The hour that the event occurred." ::= { unitEventEntry 3 } unitEventMinute OBJECT-TYPE SYNTAX TODMinute ACCESS read-only STATUS mandatory DESCRIPTION "The minute that the event occurred." ::= { unitEventEntry 4 } unitEventSecond OBJECT-TYPE SYNTAX TODSecond ACCESS read-only STATUS mandatory DESCRIPTION "The second that the event occurred." ::= { unitEventEntry 5 } unitEventMonth OBJECT-TYPE SYNTAX TODMonth ACCESS read-only STATUS mandatory DESCRIPTION "The month that the event occurred." ::= { unitEventEntry 6 } unitEventDay OBJECT-TYPE SYNTAX TODDay ACCESS read-only STATUS mandatory DESCRIPTION "The day that the event occurred." ::= { unitEventEntry 7 } unitEventYear OBJECT-TYPE SYNTAX TODYear ACCESS read-only STATUS mandatory DESCRIPTION "The year that the event occurred." ::= { unitEventEntry 8 } unitEventOriginCardNum OBJECT-TYPE SYNTAX DL5400CardId ACCESS read-only STATUS mandatory DESCRIPTION "The card type of the device originating the event." ::= { unitEventEntry 9 } unitEventOriginPortNum OBJECT-TYPE SYNTAX DL5400PortId ACCESS read-only STATUS mandatory DESCRIPTION "The port number of the device originating the event." ::= { unitEventEntry 10 } unitEventType OBJECT-TYPE SYNTAX DL5400Event ACCESS read-only STATUS mandatory DESCRIPTION "This parameter is the code for the event type. This code is used to index into an array of text strings to present a message to the human operator." ::= { unitEventEntry 11 } -- ============================================================================ -- STATISTICS -- ============================================================================ arpStats OBJECT IDENTIFIER ::= { statistics 1 } arpbadLengthField OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Bad Length Field" ::= { arpStats 1 } arpunsupportedHardware OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "unsupported Hardware" ::= { arpStats 2 } arpunsupportedProtocol OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "unsupported Protocol" ::= { arpStats 3 } arpinvalidSenderAddr OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "total number of packets with invalid sender protocol address" ::= { arpStats 4 } arpinvalidTargetAddr OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "total number of packets with invalid target protocol address" ::= { arpStats 5 } arpbadAddress OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "bad address" ::= { arpStats 6 } arppktsReceived OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "total number of packets recieved" ::= { arpStats 7 } arpshortPktsReceived OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "total number of short packets recieved" ::= { arpStats 8 } arppktsFromMeReceived OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "total number of packets from me received" ::= { arpStats 9 } arpsrcBcstReceived OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "total number of source broadcasts received" ::= { arpStats 10 } arprepliedSent OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "total number of replies sent" ::= { arpStats 11 } arpincomingRequests OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "total number of incoming requests" ::= { arpStats 12 } arprequestSent OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "total number of requests sent" ::= { arpStats 13 } arpnoMACAddr OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "No MAC address" ::= { arpStats 14 } hdlcStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF HdlcStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The hdlc statistics table." ::= { statistics 2 } hdlcStatsEntry OBJECT-TYPE SYNTAX HdlcStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Hdlc statistics table." INDEX { hdlcPortIndex } ::= { hdlcStatsTable 1 } HdlcStatsEntry ::= SEQUENCE { hdlcPortIndex INTEGER, hdlcLinkStatusBadFCSc Counter, hdlcFramesAborted Counter, hdlcFramesNotAligned Counter, hdlcOctetsRcv Counter, hdlcPctsRcv Counter, hdlcOctetsTrsmt Counter, hdlcPctsTrsmt Counter } hdlcPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Port Index" ::= { hdlcStatsEntry 1 } hdlcLinkStatusBadFCSc OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Bad FCS" ::= { hdlcStatsEntry 2 } hdlcFramesAborted OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame aborted" ::= { hdlcStatsEntry 3 } hdlcFramesNotAligned OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame not aligned" ::= { hdlcStatsEntry 4 } hdlcOctetsRcv OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Octets Received" ::= { hdlcStatsEntry 5 } hdlcPctsRcv OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Packets Received" ::= { hdlcStatsEntry 6 } hdlcOctetsTrsmt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Octets Transmitted" ::= { hdlcStatsEntry 7 } hdlcPctsTrsmt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Packets Transmitted" ::= { hdlcStatsEntry 8 } miscStats OBJECT IDENTIFIER ::= { statistics 3 } miscprotocolPctsDumped OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Rx packets with IF error on data Ethernet interface" ::= { miscStats 1 } miscnonroutablePcts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Rx packets non routable on data Ehternet interface" ::= { miscStats 2 } clrStats OBJECT IDENTIFIER ::= { statistics 4 } clearAllStats OBJECT-TYPE SYNTAX INTEGER { true(1) } ACCESS read-write STATUS mandatory DESCRIPTION "clear all statistics" ::= { clrStats 1 } clearCur15Min OBJECT-TYPE SYNTAX INTEGER { true(1) } ACCESS read-write STATUS mandatory DESCRIPTION "clear current 15 minutes statistics" ::= { clrStats 2 } clearCur24Hr OBJECT-TYPE SYNTAX INTEGER { true(1) } ACCESS read-write STATUS mandatory DESCRIPTION "clear current 24 hours statistics" ::= { clrStats 3 } clearOld15Min OBJECT-TYPE SYNTAX INTEGER { true(1) } ACCESS read-write STATUS mandatory DESCRIPTION "clear old 15 minutes statistics" ::= { clrStats 4 } clearOld24Hr OBJECT-TYPE SYNTAX INTEGER { true(1) } ACCESS read-write STATUS mandatory DESCRIPTION "clear old 24 hours statistics" ::= { clrStats 5 } -- ============================================================================ -- MAINTENANCE -- ============================================================================ maintModTable OBJECT-TYPE SYNTAX SEQUENCE OF MaintModEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of all Module Status in the system " ::= {maintenance 1} maintModEntry OBJECT-TYPE SYNTAX MaintModEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the maintModTable " INDEX { maintModIndex } ::= {maintModTable 1} MaintModEntry ::= SEQUENCE { maintModIndex INTEGER, maintModStatus DisplayString, maintOperstatus DisplayString } maintModIndex OBJECT-TYPE SYNTAX INTEGER { pp (1), ds1 (2), enet (3), mpm (4) } ACCESS read-only STATUS mandatory DESCRIPTION " The module index " ::= {maintModEntry 1} maintModStatus OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Module actual status" ::= {maintModEntry 2} maintOperstatus OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Module Operational status" ::= {maintModEntry 3} -- =========================================================================== -- TRAPS FOR DL5400 -- =========================================================================== dl5400ModulesAppear TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "There is a module appeared in the device." ::= 1 dl5400ModulesDisappear TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "There is a module disappeared in the device." ::= 2 dl5400SelfTestFail TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "Self Test failed on the unit." ::= 11 dl5400RamTestFail TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "RAM Test failed on the unit." ::= 12 dl5400RomChecksumFail TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "ROM Checksum failed on the unit." ::= 13 dl5400FlashChecksumFail TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "Flash Checksum failed on the unit." ::= 14 dl5400TimeNotSet TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "The Unit's time is not set." ::= 15 dl5400UnitRestart TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "The Unit is resetting." ::= 16 dl5400LampTestStart TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "Lamp Test started." ::= 17 dl5400LampTestEnd TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "Lamp Test terminated." ::= 18 dl5400mgmtPOSTFail TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "Management POST failed." ::= 19 dl5400mgmtPOSTok TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "Management Port OK." ::= 20 dl5400FrontTemperatureHigh TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "The unit's front temperature is high." ::= 21 dl5400FrontTemperatureOK TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "The unit's front temperature is OK." ::= 22 dl5400BackTemperatureHigh TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "The unit's back temperature is high." ::= 23 dl5400BackTemperatureOK TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "The unit's back temperature is OK." ::= 24 dl5400ExternalMajorAlarmStart TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity, unitTimeStamp } DESCRIPTION "The external major alarm input is active on the unit." ::= 25 dl5400ExternalMajorAlarmEnd TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity, unitTimeStamp } DESCRIPTION "The external major alarm input is de-activated on the unit." ::= 26 dl5400ExternalMinorAlarmStart TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity, unitTimeStamp } DESCRIPTION "The external minor alarm input is active on the unit." ::= 27 dl5400ExternalMinorAlarmEnd TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity, unitTimeStamp } DESCRIPTION "The external minor alarm input is de-activated on the unit." ::= 28 dl5400ExternalStatusAlarmStart TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity, unitTimeStamp } DESCRIPTION "The external status alarm input is active on the unit." ::= 29 dl5400ExternalStatusAlarmEnd TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity, unitTimeStamp } DESCRIPTION "The external status alarm input is de-activated on the unit." ::= 30 dl5400PrimaryClockFail TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity, unitTimeStamp } DESCRIPTION "Unit's primary clock has failed." ::= 31 dl5400PrimaryClockOk TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity, unitTimeStamp } DESCRIPTION "Unit's primary clock is OK." ::= 32 dl5400SecondaryClockFail TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity, unitTimeStamp } DESCRIPTION "Unit's Secondary clock has failed." ::= 33 dl5400SecondaryClockOk TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity, unitTimeStamp } DESCRIPTION "Unit's Secondary clock is OK." ::= 34 dl5400ExternalClockFail TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity, unitTimeStamp } DESCRIPTION "Unit's external clock has failed." ::= 35 dl5400ExternalClockOk TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity, unitTimeStamp } DESCRIPTION "Unit's external clock is OK." ::= 36 dl5400Fan1FailAlarm TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity, unitTimeStamp } DESCRIPTION "A fan 1 failed on the unit." ::= 37 dl5400Fan1Ok TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity, unitTimeStamp } DESCRIPTION "A fan is ok on the unit." ::= 38 dl5400Fan2FailAlarm TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity, unitTimeStamp } DESCRIPTION "A fan 2 failed on the unit." ::= 39 dl5400Fan2Ok TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity, unitTimeStamp } DESCRIPTION "A fan 2 is ok on the unit." ::= 40 dl5400PSFanFailed TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "Power Supply Fan Failed on the unit." ::= 41 dl5400PSFanOK TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "Power Supply Fan OK on the unit." ::= 42 dl5400PktProcessorPostFail TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "Packet Processor POST Failed." ::= 43 dl5400PktProcessorPostOk TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "Packet Processor POST OK." ::= 44 dl5400PacketProcessorMissing TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "Packet Processor Missing." ::= 45 dl5400PacketProcessorOk TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "Packet Processor OK." ::= 46 dl5400VoltageExceeds TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "Voltage has exceeded allowed operating voltage range" ::= 47 dl5400VoltageOk TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "Voltage is within allowed limits" ::= 48 dl5400ModuleProcessorFail TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "Module Processor Failed" ::= 49 dl5400ModuleProcessorOk TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "Module Processor OK." ::= 50 dl5400ModulesCfgMismatch TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "There is configuration mismatch between equipped modules." ::= 51 dl5400ModulesCfgMatch TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "There is no configuration mismatch between equipped modules." ::= 52 dl5400UsePriClkAlarm TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity, unitTimeStamp } DESCRIPTION "Using primary clock source on the unit." ::= 53 dl5400UseSecClkAlarm TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity, unitTimeStamp } DESCRIPTION "Using secondary clock source on the unit. Primary clock source failed on the unit." ::= 54 dl5400UseIntClkAlarm TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity, unitTimeStamp } DESCRIPTION "Using internal clock source on the unit. Primary and secondary clock sources failed on the unit." ::= 55 dl5400UseRxClk1Alarm TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity, unitTimeStamp } DESCRIPTION "Receive multiplexer synced to net 1." ::= 56 dl5400UseRxClk2Alarm TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity, unitTimeStamp } DESCRIPTION "Receive multiplexer synced to net 2." ::= 57 dl5400UseRxClk3Alarm TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity, unitTimeStamp } DESCRIPTION "Receive multiplexer synced to net 3." ::= 58 dl5400UseRxClk4Alarm TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity, unitTimeStamp } DESCRIPTION "Receive multiplexer synced to net 4." ::= 59 dl5400UseRxClk5Alarm TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity, unitTimeStamp } DESCRIPTION "Receive multiplexer synced to net 5." ::= 60 dl5400UseRxClk6Alarm TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity, unitTimeStamp } DESCRIPTION "Receive multiplexer synced to net 6." ::= 61 dl5400UseRxClk7Alarm TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity, unitTimeStamp } DESCRIPTION "Receive multiplexer synced to net 7." ::= 62 dl5400UseRxClk8Alarm TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity, unitTimeStamp } DESCRIPTION "Receive multiplexer synced to net 8." ::= 63 dl5400MLpppPOSTFail TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "ML-PPP POST failed." ::= 64 dl5400MLpppPOSTok TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "ML-PPP Port OK." ::= 65 dl5400MLpppModuleMissing TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "ML-PPP Module is Missing " ::= 66 dl5400MLpppModuleOK TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "ML-PPP Module is OK " ::= 67 dl5400MLpppInsufficientLinks TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "ML-PPP Insufficient links reported." ::= 68 dl5400MLpppInsufficientLinksOk TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "Insufficient ML-PPP links alarm remitted." ::= 69 dl5400ModulesFail TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "There is a module failed in the device." ::= 70 dl5400ModulesUp TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventSeverity , unitTimeStamp } DESCRIPTION "There is a module up in the device." ::= 71 dl5400LossOfSignalStart TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventOriginPortNum, unitEventSeverity , unitTimeStamp } DESCRIPTION "Loss of Signal occured on the specified Network port." ::= 100 dl5400LossOfSignalEnd TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventOriginPortNum, unitEventSeverity , unitTimeStamp } DESCRIPTION "Loss of Signal ended on the specified Network port." ::= 101 dl5400LossOfFrameStart TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventOriginPortNum, unitEventSeverity , unitTimeStamp } DESCRIPTION "Loss of Frame ended on the specified Network port." ::= 102 dl5400LossOfFrameEnd TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventOriginPortNum, unitEventSeverity , unitTimeStamp } DESCRIPTION "Loss of Frame ended on the specified Network port." ::= 103 dl5400AisStart TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventOriginPortNum, unitEventSeverity , unitTimeStamp } DESCRIPTION "AIS Alarm started on the specified Network port." ::= 104 dl5400AisEnd TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventOriginPortNum, unitEventSeverity , unitTimeStamp } DESCRIPTION "AIS Alarm started on the specified Network port." ::= 105 dl5400RaiStart TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventOriginPortNum, unitEventSeverity , unitTimeStamp } DESCRIPTION "RAI Alarm(Yellow) received on the specified Network port." ::= 106 dl5400RaiEnd TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventOriginPortNum, unitEventSeverity , unitTimeStamp } DESCRIPTION "RAI Alarm(Yellow) Ended on the specified Network port." ::= 107 dl5400netLineRemoteLoopbackStart TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventOriginPortNum, unitEventSeverity , unitTimeStamp } DESCRIPTION "Network Line/Remote Loopback on specified Network port ." ::= 158 dl5400netLineRemoteLoopbackEnd TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventOriginPortNum, unitEventSeverity , unitTimeStamp } DESCRIPTION "Network Line/Remote Loopback ended on specified Network port ." ::= 159 dl5400pppEchoTimeout TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventOriginPortNum, unitEventSeverity , unitTimeStamp } DESCRIPTION "PPP Echo Timeout." ::= 164 dl5400pppEchoTimeoutRemit TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventOriginPortNum, unitEventSeverity , unitTimeStamp } DESCRIPTION "PPP Echo Timeout Alarm Remitted." ::= 165 dl5400pppLineLoopbackStart TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventOriginPortNum, unitEventSeverity , unitTimeStamp } DESCRIPTION "PPP Line Loopback Start." ::= 166 dl5400pppLineLoopbackEnd TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventOriginPortNum, unitEventSeverity , unitTimeStamp } DESCRIPTION "PPP Line Loopback End." ::= 167 dl5400pppLinkFallbackStart TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventOriginPortNum, unitEventSeverity , unitTimeStamp } DESCRIPTION "PPP Link FallbackStart." ::= 168 dl5400pppLinkFallbackEnd TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventOriginPortNum, unitEventSeverity , unitTimeStamp } DESCRIPTION "PPP Link Fallback End." ::= 169 dl5400dteLocalLoopbackStart TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventOriginPortNum, unitEventSeverity , unitTimeStamp } DESCRIPTION "Network DTE Local Loopback on specified Network port ." ::= 170 dl5400dteLocalLoopbackEnd TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventOriginPortNum, unitEventSeverity , unitTimeStamp } DESCRIPTION "Network DTE Local Loopback ended on specified Network port ." ::= 171 dl5400dteRemoteLoopbackStart TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventOriginPortNum, unitEventSeverity , unitTimeStamp } DESCRIPTION "Network DTE Remote Loopback on specified Network port ." ::= 172 dl5400dteRemoteLoopbackEnd TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventOriginPortNum, unitEventSeverity , unitTimeStamp } DESCRIPTION "Network DTE Remote Loopback ended on specified Network port ." ::= 173 dl5400MLpppLinkDown TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventOriginPortNum, unitEventSeverity , unitTimeStamp } DESCRIPTION "ML-PPP links down caused by ML-PPP Protocol Layer." ::= 174 dl5400MLpppLinkUp TRAP-TYPE ENTERPRISE dl5400 VARIABLES { unitEventOriginPortNum, unitEventSeverity , unitTimeStamp } DESCRIPTION "ML-PPP links up caused by ML-PPP Protocol Layer." ::= 175 END