WS-INFRA-SYSMSG-MIB

File: WS-INFRA-SYSMSG-MIB.mib (8108 bytes)

Imported modules

SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
WS-INFRA-SMI-MIB WS-TYPE-MIB

Imported symbols

OBJECT-GROUP MODULE-COMPLIANCE IpAddress
Integer32 OBJECT-TYPE MODULE-IDENTITY
TruthValue wsInfraSysMsg DoActionNow

Defined Types

SysMsgSeverity  
INTEGER emergency(0), alert(1), critical(2), error(3), warning(4), notice(5), info(6), debug(7)    

WsInfraSysMsgRemoteSvrEntry  
SEQUENCE    
  wsInfraSysMsgRemoteSvrIndex INTEGER
  wsInfraSysMsgRemoteSvrIp IpAddress

Defined Values

wsInfraSysMsgModule 1.3.6.1.4.1.388.14.1.3.1
Description.
MODULE-IDENTITY    

wsInfraSysMsgEnable 1.3.6.1.4.1.388.14.1.3.1.1
Enable/Disables logging module.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

wsInfraSysMsgAggTime 1.3.6.1.4.1.388.14.1.3.1.2
If multiple messages of the same type are received in sysMsgAggTime second, only the first message will be sent followed by another message saying how many times it was repeated. The follow-up message mechanism will not be implemented in case of Snmp traps. 0 means this feature is disabled.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..60  

wsInfraSysMsgBuffer 1.3.6.1.4.1.388.14.1.3.1.3
OBJECT IDENTIFIER    

wsInfraSysMsgBufferEnable 1.3.6.1.4.1.388.14.1.3.1.3.1
Enable system message output to buffer (local log file)
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

wsInfraSysMsgBufferSeverity 1.3.6.1.4.1.388.14.1.3.1.3.2
If enabled, the system message of severity level of and below wsInfraSysMsgBufferSeverity will be sent.
Status: current Access: read-write
OBJECT-TYPE    
  SysMsgSeverity  

wsInfraSysMsgBufferClear 1.3.6.1.4.1.388.14.1.3.1.3.3
Clear buffer (local log file)
Status: current Access: read-write
OBJECT-TYPE    
  DoActionNow  

wsInfraSysMsgRemoteSvr 1.3.6.1.4.1.388.14.1.3.1.4
OBJECT IDENTIFIER    

wsInfraSysMsgRemoteSvrEnable 1.3.6.1.4.1.388.14.1.3.1.4.1
Enable system message output to remote system log server
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

wsInfraSysMsgRemoteSvrSeverity 1.3.6.1.4.1.388.14.1.3.1.4.2
If enabled, the system message of severity level of and below wsInfraSysMsgRemoteSvrSeverity will be sent.
Status: current Access: read-write
OBJECT-TYPE    
  SysMsgSeverity  

wsInfraSysMsgRemoteSvrFacility 1.3.6.1.4.1.388.14.1.3.1.4.3
Used to specify which switch is logging the message.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER logLocal0(0), logLocal1(1), logLocal2(2), logLocal3(3), logLocal4(4), logLocal5(5), logLocal6(6), logLocal7(7)  

wsInfraSysMsgRemoteSvrTable 1.3.6.1.4.1.388.14.1.3.1.4.4
Table of remote log servers
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WsInfraSysMsgRemoteSvrEntry

wsInfraSysMsgRemoteSvrEntry 1.3.6.1.4.1.388.14.1.3.1.4.4.1
Status: current Access: not-accessible
OBJECT-TYPE    
  WsInfraSysMsgRemoteSvrEntry  

wsInfraSysMsgRemoteSvrIndex 1.3.6.1.4.1.388.14.1.3.1.4.4.1.1
Simple index
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER 1..255  

wsInfraSysMsgRemoteSvrIp 1.3.6.1.4.1.388.14.1.3.1.4.4.1.2
Ip of the syslog server. Row inactive when Ip = 0.0.0.0
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

wsInfraSysMsgConsole 1.3.6.1.4.1.388.14.1.3.1.5
OBJECT IDENTIFIER    

wsInfraSysMsgConsoleEnable 1.3.6.1.4.1.388.14.1.3.1.5.1
Enable system message output to console
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

wsInfraSysMsgConsoleSeverity 1.3.6.1.4.1.388.14.1.3.1.5.2
If enabled, the system message of severity level of and below wsInfraSysMsgConsoleSeverity will be sent.
Status: current Access: read-write
OBJECT-TYPE    
  SysMsgSeverity  

wsInfraSysMsgMIBConformance 1.3.6.1.4.1.388.14.1.3.1.6
OBJECT IDENTIFIER    

wsInfraSysMsgMIBCompliances 1.3.6.1.4.1.388.14.1.3.1.6.1
OBJECT IDENTIFIER    

wsInfraSysMsgMIBCompliance 1.3.6.1.4.1.388.14.1.3.1.6.1.1
Description.
Status: current Access: read-write
MODULE-COMPLIANCE    

wsInfraSysMsgMIBGroups 1.3.6.1.4.1.388.14.1.3.1.6.2
OBJECT IDENTIFIER    

wsInfraSysMsgMIBGroup 1.3.6.1.4.1.388.14.1.3.1.6.2.1
Description.
Status: current Access: read-write
OBJECT-GROUP