UBQS-SYSTEM-MIB
File:
UBQS-SYSTEM-MIB.mib (18092 bytes)
Imported modules
Imported symbols
Defined Types
UbiSysRedundancyInfoEntry |
|
SEQUENCE |
|
|
|
|
ubiSCURedundancyRole |
INTEGER |
|
|
ubiSCUPosition |
INTEGER |
|
|
ubiSCUMngLinkStatus |
INTEGER |
|
|
ubiSCUIpAddress |
IpAddress |
|
|
ubiSCUPeerEquipStatus |
INTEGER |
|
UbiSysBarcodePowerEntry |
|
SEQUENCE |
|
|
|
|
ubiSysBarcodePowerIndex |
INTEGER |
|
|
ubiSysBarcodePowerString |
DisplayString |
|
UbiSysBarcodeFanEntry |
|
SEQUENCE |
|
|
|
|
ubiSysBarcodeFanIndex |
INTEGER |
|
|
ubiSysBarcodeFanString |
DisplayString |
|
UbiSysBarcodeUplinkEntry |
|
SEQUENCE |
|
|
|
|
ubiSysBarcodeUplinkIndex |
INTEGER |
|
|
ubiSysBarcodeUplinkString |
DisplayString |
|
UbiSysBarcodeSlotEntry |
|
SEQUENCE |
|
|
|
|
ubiSysBarcodeSlotIndex |
INTEGER |
|
|
ubiSysBarcodeSlotString |
DisplayString |
|
UbiSysBarcodeScuEntry |
|
SEQUENCE |
|
|
|
|
ubiSysBarcodeScuIndex |
INTEGER |
|
|
ubiSysBarcodeScuString |
DisplayString |
|
Defined Values
ubiSystemMIB |
1.3.6.1.4.1.7800.100.1 |
The UBQS-SYSTEM-MIB is used to get
the system information. |
MODULE-IDENTITY |
|
|
|
ubiSysInfo |
1.3.6.1.4.1.7800.100.1.1.2 |
OBJECT IDENTIFIER |
|
|
|
ubiSysReset |
1.3.6.1.4.1.7800.100.1.1.1 |
Reset the system. |
Status: mandatory |
Access: write-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
reset(1) |
|
ubiSysModel |
1.3.6.1.4.1.7800.100.1.1.2.1 |
The object identifier for the manufacturer model. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OBJECT IDENTIFIER |
|
|
ubiHwVersion |
1.3.6.1.4.1.7800.100.1.1.2.2 |
Hardware version of the system. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
ubiSwVersion |
1.3.6.1.4.1.7800.100.1.1.2.3 |
Software version of the system. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
ubiReleaseDate |
1.3.6.1.4.1.7800.100.1.1.2.4 |
The date of release for system OS. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
ubiSysClock |
1.3.6.1.4.1.7800.100.1.1.2.7 |
Current local time of the system.
Clock SET:
HH:MM:SS - Current Time
<1-31> - Day of the month
MONTH - Month of the year (First three letters of the month)
<1993-2035> - Year
SET Example
13:10:00 3 Jan 2010
|
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
ubiSysBannerLogin |
1.3.6.1.4.1.7800.100.1.1.2.9.1 |
null string -> no banner login
'default' -> banner login default
STRING -> banner login WORD |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
ubiSysBannerMotd |
1.3.6.1.4.1.7800.100.1.1.2.9.2 |
null string -> no banner motd
'default' -> banner motd default
STRING -> banner motd WORD |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
ubiSysRedundancyInfoEntry |
1.3.6.1.4.1.7800.100.1.1.7.1.1 |
Entry of redundancy information |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
UbiSysRedundancyInfoEntry |
|
|
ubiSCURedundancyRole |
1.3.6.1.4.1.7800.100.1.1.7.1.1.1 |
SCU role |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
active(1), standby(2) |
|
ubiSCUPosition |
1.3.6.1.4.1.7800.100.1.1.7.1.1.2 |
SCU postion |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
left(1), right(2) |
|
ubiSCUMngLinkStatus |
1.3.6.1.4.1.7800.100.1.1.7.1.1.3 |
mng port status of SCU |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
down(0), up(1) |
|
ubiSCUIpAddress |
1.3.6.1.4.1.7800.100.1.1.7.1.1.4 |
IP address of SCU |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
ubiSCUPeerEquipStatus |
1.3.6.1.4.1.7800.100.1.1.7.1.1.5 |
Peer Equip status of SCU |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unequip(0), equip(1) |
|
ubiSysRedundancyReload |
1.3.6.1.4.1.7800.100.1.1.7.2 |
Reload Active and/or Standby |
Status: current |
Access: write-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
reload-peer(1), reload-shelf(2) |
|
ubiLedTestTimeout |
1.3.6.1.4.1.7800.100.1.1.6.1 |
The timeout to terminate the LED Test.
If the timeout is zero, that is set to default. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..300 |
|
ubiLedTestTrigger |
1.3.6.1.4.1.7800.100.1.1.6.2 |
Trigger and stop the LED Test. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
none(0), testing(1), stop(2) |
|
ubiSysBarcodePowerEntry |
1.3.6.1.4.1.7800.100.1.1.8.2.1 |
Barcode Information about the power. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
UbiSysBarcodePowerEntry |
|
|
ubiSysBarcodePowerIndex |
1.3.6.1.4.1.7800.100.1.1.8.2.1.1 |
A unique value for each power entity |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ubiSysBarcodeFanEntry |
1.3.6.1.4.1.7800.100.1.1.8.3.1 |
Barcode Information about the fan |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
UbiSysBarcodeFanEntry |
|
|
ubiSysBarcodeFanIndex |
1.3.6.1.4.1.7800.100.1.1.8.3.1.1 |
A unique value for each fan entity |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ubiSysBarcodeUplinkEntry |
1.3.6.1.4.1.7800.100.1.1.8.4.1 |
Barcode Information about the uplink module. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
UbiSysBarcodeUplinkEntry |
|
|
ubiSysBarcodeUplinkIndex |
1.3.6.1.4.1.7800.100.1.1.8.4.1.1 |
A unique value for each uplink module. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ubiSysBarcodeSlotEntry |
1.3.6.1.4.1.7800.100.1.1.8.5.1 |
Barcode Information about the slot. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
UbiSysBarcodeSlotEntry |
|
|
ubiSysBarcodeSlotIndex |
1.3.6.1.4.1.7800.100.1.1.8.5.1.1 |
A unique value for each slot. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ubiSysBarcodeScuEntry |
1.3.6.1.4.1.7800.100.1.1.8.6.1 |
Barcode Information about the SCU. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
UbiSysBarcodeScuEntry |
|
|
ubiSysBarcodeScuIndex |
1.3.6.1.4.1.7800.100.1.1.8.6.1.1 |
A unique value for each SCU. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ubiSysMIBCompliance |
1.3.6.1.4.1.7800.100.1.3.1.1 |
The compliance statement for entities which implement
the Ubiquoss system MIB. |
Status: current |
Access: read-only |
MODULE-COMPLIANCE |
|
|
|
ubiSysInfoMIBGroup |
1.3.6.1.4.1.7800.100.1.3.2.1 |
The collection of objects which are used to get the
system information |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
ubiSysRscMIBGroup |
1.3.6.1.4.1.7800.100.1.3.2.2 |
The collection of objects which are used to manager the
system resource |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
ubiSysMiscGroup |
1.3.6.1.4.1.7800.100.1.3.2.3 |
The collection of objects which are used to manager the
miscellaneous information of system. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|