TPT-BAY-MIB
File:
TPT-BAY-MIB.mib (7570 bytes)
Imported modules
Imported symbols
Defined Types
SlotStatus |
|
An indication of slot status |
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
empty(0), active(1), error(2) |
|
SlotEvent |
|
An indication of events occuring in slot |
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
insert(0), remove(1) |
|
SlotModuleType |
|
Type of module present in the slot. |
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
type-12-port-1g-copper(1), type-12-port-1g-sfp(2), type-8-port-10g-sfp(3), type-2-port-40g-sfp(4), type-6100(5), type-5100(6), type-2500(7), type-1400(8), type-660(9), type-330(10), type-110(11), type-10(12), type-empty(13), type-8-port-1g-copper-bypass(14), type-4-port-1g-sfp-sr-bypass(15), type-4-port-1g-sfp-lr-bypass(16), type-4-port-10g-sfp-sr-bypass(17), type-4-port-10g-sfp-lr-bypass(18) |
|
SlotTempEntry |
|
SEQUENCE |
|
|
|
|
slotTempIndex |
Unsigned32 |
|
|
slotName |
OCTET STRING |
Size(0..64) |
|
slotModuleName |
OCTET STRING |
Size(0..64) |
|
slotStatus |
SlotStatus |
|
|
slotModuleSerialNum |
OCTET STRING |
Size(0..64) |
|
slotModuleType |
SlotModuleType |
|
Defined Values
tpt-slot-objs |
1.3.6.1.4.1.10734.3.3.2.17 |
Slot details on the device.
Copyright (C) 2016 Trend Micro Incorporated. All Rights Reserved.
Trend Micro makes no warranty of any kind with regard to this material,
including, but not limited to, the implied warranties of merchantability
and fitness for a particular purpose. Trend Micro shall not be liable for
errors contained herein or for incidental or consequential damages in
connection with the furnishing, performance, or use of this material. This
document contains proprietary information, which is protected by copyright. No
part of this document may be photocopied, reproduced, or translated into
another language without the prior written consent of Trend Micro. The
information is provided 'as is' without warranty of any kind and is subject to
change without notice. The only warranties for Trend Micro products and
services are set forth in the express warranty statements accompanying such
products and services. Nothing herein should be construed as constituting an
additional warranty. Trend Micro shall not be liable for technical or editorial
errors or omissions contained herein. TippingPoint(R), the TippingPoint logo, and
Digital Vaccine(R) are registered trademarks of Trend Micro. All other company
and product names may be trademarks of their respective holders. All rights
reserved. This document contains confidential information, trade secrets or
both, which are the property of Trend Micro. No part of this documentation may
be reproduced in any form or by any means or used to make any derivative work
(such as translation, transformation, or adaptation) without written permission
from Trend Micro or one of its subsidiaries. All other company and product
names may be trademarks of their respective holders.
|
MODULE-IDENTITY |
|
|
|
slotTempTable |
1.3.6.1.4.1.10734.3.3.2.17.1 |
Table of slots on the device. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
SlotTempEntry |
|
slotTempEntry |
1.3.6.1.4.1.10734.3.3.2.17.1.1 |
An entry in the slot table.
Rows cannot be created or deleted. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SlotTempEntry |
|
|
slotTempIndex |
1.3.6.1.4.1.10734.3.3.2.17.1.1.1 |
Index into the slot table, starting with 1. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
slotName |
1.3.6.1.4.1.10734.3.3.2.17.1.1.2 |
String description of the name of slot. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..64) |
|
slotModuleName |
1.3.6.1.4.1.10734.3.3.2.17.1.1.3 |
String description of the type of module in slot. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..64) |
|
slotStatus |
1.3.6.1.4.1.10734.3.3.2.17.1.1.4 |
status of this slot |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
SlotStatus |
|
|
slotModuleSerialNum |
1.3.6.1.4.1.10734.3.3.2.17.1.1.5 |
String description of the serial number of the module in the slot. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..64) |
|
slotModuleType |
1.3.6.1.4.1.10734.3.3.2.17.1.1.6 |
Type of module present in the slot. This is applicable mainly for the
newer devices like 6100 and above, which have multiple I/O slots. For
older systems like 5100 which don't have slots, the module type would be
the device model number. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
SlotModuleType |
|
|
tptSlotDeviceID |
1.3.6.1.4.1.10734.3.3.3.1.281 |
The unique identifier of the device sending this notification. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..40) |
|
tptSlotID |
1.3.6.1.4.1.10734.3.3.3.1.282 |
The slot index which is sending this notification. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
tptSlotEvent |
1.3.6.1.4.1.10734.3.3.3.1.283 |
The event occuring in the slot which is sending this notification. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
SlotEvent |
|
|
tptSlotChangeNotify |
1.3.6.1.4.1.10734.3.3.3.0.54 |
Notification: Module was inserted on this device |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|