QB-TIMING-MIB
File:
QB-TIMING-MIB.mib (15737 bytes)
Imported modules
Imported symbols
Defined Types
QbTimingCableLength |
|
The range of feet of cable from the QB5000 to
the Building Integrated Timing Supply. |
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
length0to110ft(1), length110to220ft(2), length220to330ft(3), length330to440ft(4), length440to550ft(5), length550to660ft(6), lengthGreater660ft(7) |
|
QbTimingFraming |
|
Indicates the signal framing. |
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
other(1), dsx1ESF(2), dsx1D4(3), dsx1E1(4), dsx1E1CRC(5), dsx1E1MF(6), dsx1E1CRCMF(7), dsx1Unframed(8), dsx1E1Unframed(9), dsx1DS2M12(10), dsx2E2(11), dsx1SF(12) |
|
QbTimingPort |
|
Indicates a selected timing port. |
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
timing-port1(1), timing-port2(2) |
|
QbTimingPortEntry |
|
SEQUENCE |
|
|
|
|
qbTimingPort |
QbTimingPort |
|
|
qbTimingPortName |
DisplayString |
|
|
qbTimingPortFormat |
INTEGER |
|
|
qbTimingPortLineCoding |
INTEGER |
|
|
qbTimingPortFraming |
QbTimingFraming |
|
|
qbTimingPortCableLength |
QbTimingCableLength |
|
|
qbTimingPortImpedanceMode |
INTEGER |
|
|
qbTimingPortOperStatus |
INTEGER |
|
|
qbTimingPortInOperStatus |
INTEGER |
|
Defined Values
qbTimingMIB |
1.3.6.1.4.1.4323.2.11 |
This module defines objects for timing management of OAS
system. |
MODULE-IDENTITY |
|
|
|
qbTimingModeAdminStatus |
1.3.6.1.4.1.4323.2.11.1.1.1 |
The object is used to set the desired timing configuration
of an OAS system.
Setting this object to 'freerun(1)' depending on the
installed TGS3 option, causes one of the following results:
1. If the board in the MAIN slot does not have the
TGS3 card installed, the local oscillator on the board
is used as the synchronization source.
2. If the board in the MAIN slot has the TGS3 card
installed, the synchronization is derived from the TGS3 card.
Setting this object to 'external(2)' selects the
external BITS input as the timing source.
Setting this object to 'loop(3)' causes the timing
mode to switch loop-timed. When the object is set to
'loop', the 'qbTimingLoopInLineRef' must be set to an
appropriate ifindex.
The value holdover can not be set here. When qbTimingModeAdminStatus is loop(3), and
you set the qbTimingHoldoverCtl
to holdover, qbTimingModeAdminStatus will have a value of holdover |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
freerun(1), external(2), loop(3), holdover(8) |
|
qbTimingModeOperStatus |
1.3.6.1.4.1.4323.2.11.1.1.2 |
The object indicates the actual status of the timing
of an OAS system.
A value 'notOperational(6)' indicates that the
shelf doesn't have operational timing equpment
available.
A value 'freerun(1) indicates the free-running timing
mode.
A value 'external(2)' indicates the external timing
mode of the shelf.
A value 'loop(3)' indicates the loop-timed timing
mode of the shelf.
A value 'holdoverMntc(4)' indicates the timing mode
was intentionally switched to 'holdover' by setting
'qbTimingHooldover' to 'holdover'.
A value 'holdoverAuto(5)' indicates the timing mode
was intentionally switched due to hardware problems |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
freerun(1), external(2), loop(3), holdoverMntc(4), holdoverAuto(5), notOperational(6) |
|
qbTimingOutputMode |
1.3.6.1.4.1.4323.2.11.1.1.3 |
This object is used to disable or enable the BITS output
signals at the timing ports. Setting the object to
'lock' or track must be accompanied by setting
'qbTimingOutLineRef to an appropriate ifIndex |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disable(1), lock(2), track(3) |
|
qbTimingHoldoverCtl |
1.3.6.1.4.1.4323.2.11.1.1.4 |
The object forces the OAS system into one of two
states depending on whether the TGS3 is equipped.
If the TGS3 card is not installed the set command fails.
Setting this object to 'holdover(1)', when the TGS3
card is installed,forces the OAS system into holdover
maintenance mod. Setting the value to 'holdover' is
only valid when the system 'qbTimingOperStatus' is either
'external' or 'loop'
Setting this object to 'clearholdover(2)' causes the
timing mode to reinstate the original timing mode and
can achieved if 'qbTimingOperStatus' is set to 'holdoverMntc'. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
holdover(1), clearholdover(2) |
|
qbTimingSourceStatus |
1.3.6.1.4.1.4323.2.11.1.1.5 |
This is used to switch the external output source to the
primary or secondary source. Note: this object works in
conjunction with 'qbTimingModeAdminStatus'. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
primary(1), secondary(2) |
|
qbTimingInLineRef |
1.3.6.1.4.1.4323.2.11.1.1.6 |
The value of ifIndex corresponding to the optical
port interface that provides a source for the system
time reference. The object is changed in conjunction
with 'qbTimingOutputMode'.
When 'qbTimingModeAdminStatus' is set to
'freerun' the object is irrelevant and the agent
returns 0.
Note: only slots main-a, au-1 or au-7 may be selected
for this port.
The object is relevant only
for WAN622, S622-T, Q-155, Q-155T, D155VT/VC, and
D155VT/VC-T ports. Only one port at the time can be used as the
timing source. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
InterfaceIndexOrZero |
|
|
qbTimingOutLineRef |
1.3.6.1.4.1.4323.2.11.1.1.7 |
The value of ifIndex corresponding to the
port interface that provides a line reference for the external
timing outputs. The object is changed in conjunction
with 'qbTimingOutputMode'. When 'qbTimingAdminStatus' is set to
'freerun' this object is irrelevant and the agent
returns 0. Note: this object is relevant only for main and
au-1/au-2 and au-7/au-8 slots. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
InterfaceIndexOrZero |
|
|
qbTimingPortTable |
1.3.6.1.4.1.4323.2.11.1.1.8 |
A list of timing port entries. The number of entries is
2 (timing_port1 and timing_port2). Every entry contains
the following configuration settings: the format line,
format cable length(for ports configured for as DS1),
line coding, framing
and impendance(for ports configures as E1). |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
QbTimingPortEntry |
|
qbTimingPortEntry |
1.3.6.1.4.1.4323.2.11.1.1.8.1 |
Entry containing information for a particular timing
port in the OAS system. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
QbTimingPortEntry |
|
|
qbTimingPort |
1.3.6.1.4.1.4323.2.11.1.1.8.1.1 |
The timing port number |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
QbTimingPort |
|
|
qbTimingPortName |
1.3.6.1.4.1.4323.2.11.1.1.8.1.2 |
A descriptive string of the timing port |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
qbTimingPortLineCoding |
1.3.6.1.4.1.4323.2.11.1.1.8.1.4 |
The object is used to set the signal linecoding. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
dsx1JBZS(1), dsx1B8ZS(2), dsx1HDB3(3), dsx1ZBTSI(4), dsx1AMI(5), other(6), dsx1B6ZS(7) |
|
qbTimingPortCableLength |
1.3.6.1.4.1.4323.2.11.1.1.8.1.6 |
The object is used to set the range of cable from the
OAS to the external synchronization source. The value
entered is interpreted by the agent to have a cable length
within the range associated with the value. Note: this value
is applicable only for DS1 ports. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
QbTimingCableLength |
|
|
qbTimingPortImpedanceMode |
1.3.6.1.4.1.4323.2.11.1.1.8.1.7 |
The object is used to set the impendance in ohms.
Note: this value is applicable only for E1 ports. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
75 | 120 |
|
qbTimingPortOperStatus |
1.3.6.1.4.1.4323.2.11.1.1.8.1.8 |
The object indicates the output operational status of the
timing port.
up(1) - timing port up
down(2)- timing port down
los(3) - Los of Signal
eqpFailure(4) - Equipment problem or TGS card is removed |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
up(1), down(2), los(3), eqpFailure(4) |
|
qbTimingPortInOperStatus |
1.3.6.1.4.1.4323.2.11.1.1.8.1.9 |
The object indicates the input operational status of the
timing port.
up(1) - timing port up
down(2)- timing port down
los(3) - Los of Signal
eqpFailure(4) - Equipment problem or TGS card is removed |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
up(1), down(2), los(3), eqpFailure(4) |
|
qbTimingCompliance |
1.3.6.1.4.1.4323.2.11.3.1.1 |
The compliance statement for all agents that support this
MIB. A compliant agent implements all objects defined in this
MIB. |
Status: current |
Access: read-only |
MODULE-COMPLIANCE |
|
|
|
qbTimingAllGroup |
1.3.6.1.4.1.4323.2.11.3.2.1 |
The set of all accessible objects in this MIB. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|