PRVT-MPLS-LDP-MIB

File: PRVT-MPLS-LDP-MIB.mib (148354 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF SNMPv2-TC
INET-ADDRESS-MIB MPLS-TC-PRIV-STDEXT-MIB IF-MIB
MPLS-LSR-STD-MIB PRVT-CR-LDP-MIB

Imported symbols

OBJECT-TYPE MODULE-IDENTITY NOTIFICATION-TYPE
Integer32 Counter32 Unsigned32
MODULE-COMPLIANCE OBJECT-GROUP NOTIFICATION-GROUP
TEXTUAL-CONVENTION RowStatus TimeInterval
TruthValue TimeStamp StorageType
InetAddressPrefixLength InetAddressType InetAddress
InetPortNumber mplsStdMIB MplsLabelDistributionMethod
MplsLdpIdentifier MplsLdpLabelType MplsLspType
MplsLsrIdentifier MplsRetentionMode MplsAtmVcIdentifier
InterfaceIndexOrZero MplsIndexType prvtcrldpPmIndex
prvtcrldpSigIndex mpls

Defined Types

MplsLabel  
This value represents an MPLS label. The label contents are specific to the label being represented. The label carried in an MPLS shim header (for LDP, the Generic Label) is a 20-bit number represented by 4 octets. Bits 0-19 contain a label or a reserved label value. Bits 20-31 MUST be zero. The frame relay label can be either 10-bits or 23-bits depending on the DLCI field size and the upper 22-bits or upper 9-bits must be zero, respectively. For an ATM label the lower 16-bits represents the VCI, the next 12-bits represents the VPI and the remaining bits MUST be zero.
TEXTUAL-CONVENTION    
  Integer32 0..2147483647  

MplsLdpLabelTypes  
The Layer 2 label types which are defined for MPLS LDP are generic(1), atm(2), or frameRelay(3).
TEXTUAL-CONVENTION    
  INTEGER generic(1), atm(2), frameRelay(3)  

MplsLdpLsrEntry  
SEQUENCE    
  mplsLdpLsrId MplsLsrIdentifier
  mplsLdpLsrLoopDetectionCapable INTEGER

MplsLdpEntityEntry  
SEQUENCE    
  mplsLdpEntityLdpId MplsLdpIdentifier
  mplsLdpEntityIndex Unsigned32
  mplsLdpEntityProtocolVersion Integer32
  mplsLdpEntityAdminStatus INTEGER
  mplsLdpEntityOperStatus INTEGER
  mplsLdpEntityWellKnownTcpDiscoveryPort InetPortNumber
  mplsLdpEntityWellKnownUdpDiscoveryPort InetPortNumber
  mplsLdpEntityMaxPduLength Unsigned32
  mplsLdpEntityKeepAliveHoldTimer Unsigned32
  mplsLdpEntityHelloHoldTimer Unsigned32
  mplsLdpEntityInitSessionThreshold Integer32
  mplsLdpEntityLabelDistMethod MplsLabelDistributionMethod
  mplsLdpEntityLabelRetentionMode MplsRetentionMode
  mplsLdpEntityPathVectorLimit Integer32
  mplsLdpEntityHopCountLimit Integer32
  mplsLdpEntityTransportAddrKind INTEGER
  mplsLdpEntityTargetPeer TruthValue
  mplsLdpEntityTargetPeerAddrType InetAddressType
  mplsLdpEntityTargetPeerAddr InetAddress
  mplsLdpEntityLabelType MplsLdpLabelType
  mplsLdpEntityDiscontinuityTime TimeStamp
  mplsLdpEntityStorageType StorageType
  mplsLdpEntityRowStatus RowStatus
  mplsLdpEntityWildcardEntity TruthValue

MplsLdpEntityStatsEntry  
SEQUENCE    
  mplsLdpEntityStatsSessionAttempts Counter32
  mplsLdpEntityStatsSessionRejectedNoHelloErrors Counter32
  mplsLdpEntityStatsSessionRejectedAdErrors Counter32
  mplsLdpEntityStatsSessionRejectedMaxPduErrors Counter32
  mplsLdpEntityStatsSessionRejectedLRErrors Counter32
  mplsLdpEntityStatsBadLdpIdentifierErrors Counter32
  mplsLdpEntityStatsBadPduLengthErrors Counter32
  mplsLdpEntityStatsBadMessageLengthErrors Counter32
  mplsLdpEntityStatsBadTlvLengthErrors Counter32
  mplsLdpEntityStatsMalformedTlvValueErrors Counter32
  mplsLdpEntityStatsKeepAliveTimerExpErrors Counter32
  mplsLdpEntityStatsShutdownReceivedNotifications Counter32
  mplsLdpEntityStatsShutdownSentNotifications Counter32

MplsLdpPeerEntry  
SEQUENCE    
  mplsLdpPeerLdpId MplsLdpIdentifier
  mplsLdpPeerLabelDistMethod MplsLabelDistributionMethod
  mplsLdpPeerPathVectorLimit Integer32
  mplsLdpPeerTransportAddrType InetAddressType
  mplsLdpPeerTransportAddr InetAddress

MplsLdpSessionEntry  
SEQUENCE    
  mplsLdpSessionStateLastChange TimeStamp
  mplsLdpSessionState INTEGER
  mplsLdpSessionRole INTEGER
  mplsLdpSessionProtocolVersion Integer32
  mplsLdpSessionKeepAliveHoldTimeRemaining TimeInterval
  mplsLdpSessionKeepAliveTime Unsigned32
  mplsLdpSessionMaxPduLength Unsigned32
  mplsLdpSessionDiscontinuityTime TimeStamp
  mplsLdpSessionConfiguredHoldTime Unsigned32
  mplsLdpSessionPeerHoldTime Unsigned32
  mplsLdpSessionHoldTimeInUse Unsigned32

MplsLdpSessionStatsEntry  
SEQUENCE    
  mplsLdpSessionStatsUnknownMesTypeErrors Counter32
  mplsLdpSessionStatsUnknownTlvErrors Counter32

MplsLdpHelloAdjacencyEntry  
SEQUENCE    
  mplsLdpHelloAdjacencyIndex Unsigned32
  mplsLdpHelloAdjacencyHoldTimeRemaining TimeInterval
  mplsLdpHelloAdjacencyHoldTime Unsigned32
  mplsLdpHelloAdjacencyType INTEGER
  mplsLdpHelloAdjacencyConfiguredHoldTime Unsigned32
  mplsLdpHelloAdjacencyPeerHoldTime Unsigned32

MplsInSegmentLdpLspEntry  
SEQUENCE    
  mplsInSegmentLdpLspIndex MplsIndexType
  mplsInSegmentLdpLspLabelType MplsLdpLabelType
  mplsInSegmentLdpLspType MplsLspType

MplsOutSegmentLdpLspEntry  
SEQUENCE    
  mplsOutSegmentLdpLspIndex MplsIndexType
  mplsOutSegmentLdpLspLabelType MplsLdpLabelType
  mplsOutSegmentLdpLspType MplsLspType

MplsFecEntry  
SEQUENCE    
  mplsFecIndex Unsigned32
  mplsFecType INTEGER
  mplsFecAddrType InetAddressType
  mplsFecAddr InetAddress
  mplsFecAddrPrefixLength InetAddressPrefixLength
  mplsFecStorageType StorageType

MplsLdpLspFecEntry  
SEQUENCE    
  mplsLdpLspFecSegment INTEGER
  mplsLdpLspFecSegmentIndex MplsIndexType
  mplsLdpLspFecIndex Integer32
  mplsLdpLspFecStorageType StorageType
  mplsLdpLspFecRowStatus RowStatus

MplsLdpSessionPeerAddrEntry  
SEQUENCE    
  mplsLdpSessionPeerAddrIndex Unsigned32
  mplsLdpSessionPeerNextHopAddrType InetAddressType
  mplsLdpSessionPeerNextHopAddr InetAddress

MplsLdpEntityIndexNextEntry  
SEQUENCE    
  mplsLdpEntityIndexNext Unsigned32

MplsLdpEntityAtmEntry  
SEQUENCE    
  mplsLdpEntityAtmIfIndexOrZero InterfaceIndexOrZero
  mplsLdpEntityAtmMergeCap INTEGER
  mplsLdpEntityAtmLRComponents Unsigned32
  mplsLdpEntityAtmVcDirectionality INTEGER
  mplsLdpEntityAtmLsrConnectivity INTEGER
  mplsLdpEntityAtmDefaultControlVpi INTEGER
  mplsLdpEntityAtmDefaultControlVci MplsAtmVcIdentifier
  mplsLdpEntityAtmUnlabTrafVpi INTEGER
  mplsLdpEntityAtmUnlabTrafVci MplsAtmVcIdentifier
  mplsLdpEntityAtmStorageType StorageType

MplsLdpEntityAtmLREntry  
SEQUENCE    
  mplsLdpEntityAtmLRMinVpi Integer32
  mplsLdpEntityAtmLRMinVci MplsAtmVcIdentifier
  mplsLdpEntityAtmLRMaxVpi INTEGER
  mplsLdpEntityAtmLRMaxVci MplsAtmVcIdentifier
  mplsLdpEntityAtmLRStorageType StorageType

MplsLdpAtmSessionEntry  
SEQUENCE    
  mplsLdpSessionAtmLRLowerBoundVpi Integer32
  mplsLdpSessionAtmLRLowerBoundVci MplsAtmVcIdentifier
  mplsLdpSessionAtmLRUpperBoundVpi INTEGER
  mplsLdpSessionAtmLRUpperBoundVci MplsAtmVcIdentifier

MplsLdpEntityFrameRelayEntry  
SEQUENCE    
  mplsLdpEntityFrameRelayIfIndexOrZero InterfaceIndexOrZero
  mplsLdpEntityFrameRelayMergeCap INTEGER
  mplsLdpEntityFrameRelayLRComponents Unsigned32
  mplsLdpEntityFrameRelayVcDirectionality INTEGER
  mplsLdpEntityFrameRelayStorageType StorageType

MplsLdpEntityFrameRelayLREntry  
SEQUENCE    
  mplsLdpEntityFrameRelayLRMinDlci Integer32
  mplsLdpEntityFrameRelayLRMaxDlci INTEGER
  mplsLdpEntityFrameRelayLRLen INTEGER
  mplsLdpEntityFrameRelayLRStorageType StorageType

MplsLdpFrameRelaySessionEntry  
SEQUENCE    
  mplsLdpFrameRelaySessionMinDlci Integer32
  mplsLdpFrameRelaySessionMaxDlci INTEGER
  mplsLdpFrameRelaySessionLen INTEGER

MplsLdpEntityGenericLREntry  
SEQUENCE    
  mplsLdpEntityGenericLRMin Unsigned32
  mplsLdpEntityGenericLRMax Unsigned32
  mplsLdpEntityGenericLabelSpace INTEGER
  mplsLdpEntityGenericIfIndexOrZero InterfaceIndexOrZero
  mplsLdpEntityGenericLRStorageType StorageType

Defined Values

mplsLdpStdMIB 78.5.1
This MIB contains managed object definitions for the 'Multiprotocol Label Switching, Label Distribution Protocol, LDP'.
MODULE-IDENTITY    

mplsLdpObjects 78.5.1.1
OBJECT IDENTIFIER    

mplsLdpNotifications 78.5.1.2.0
OBJECT IDENTIFIER    

mplsLdpConformance 78.5.1.3
OBJECT IDENTIFIER    

mplsLdpLsrObjects 78.5.1.1.1
OBJECT IDENTIFIER    

mplsLdpEntityObjects 78.5.1.1.2
OBJECT IDENTIFIER    

mplsLdpLsrTable 78.5.1.1.1.1
This table contains information about the Label Switching Router (LSR) or Label Edge Router (LER) that is running the MPLS Label Distribution Protocol.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MplsLdpLsrEntry

mplsLdpLsrEntry 78.5.1.1.1.1.1
An entry in this table contains the LSR objects specific to an instance of PRVT-CR-LDP.
Status: current Access: not-accessible
OBJECT-TYPE    
  MplsLdpLsrEntry  

mplsLdpLsrId 78.5.1.1.1.1.1.1
The Label Switching Router's Identifier.
Status: current Access: read-only
OBJECT-TYPE    
  MplsLsrIdentifier  

mplsLdpLsrLoopDetectionCapable 78.5.1.1.1.1.1.2
A indication of whether this Label Switching Router supports loop detection. none(1) -- Loop Detection is not supported on this LSR. other(2) -- Loop Detection is supported but by a method other than those listed below. hopCount(3) -- Loop Detection is supported by Hop Count only. pathVector(4) -- Loop Detection is supported by Path Vector only. hopCountAndPathVector(5) -- Loop Detection is supported by both Hop Count And Path Vector. Since Loop Detection is determined during Session Initialization, an individual session may not be running with loop detection. This object simply gives an indication of whether or not the LSR has the ability to support Loop Detection and which types.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), other(2), hopCount(3), pathVector(4), hopCountAndPathVector(5)  

mplsLdpEntityTable 78.5.1.1.2.1
This table contains information about the MPLS Label Distribution Protocol Entities which exist on this Label Switching Router (LSR) or Label Edge Router (LER).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MplsLdpEntityEntry

mplsLdpEntityEntry 78.5.1.1.2.1.1
An entry in this table represents an LDP entity. An entry can be created by a network administrator or by an SNMP agent as instructed by LDP.
Status: current Access: not-accessible
OBJECT-TYPE    
  MplsLdpEntityEntry  

mplsLdpEntityLdpId 78.5.1.1.2.1.1.1
The LDP identifier. The first four octets encode an IP address assigned to the LSR, and the last two octets identify a specific label space within the LSR.
Status: current Access: not-accessible
OBJECT-TYPE    
  MplsLdpIdentifier  

mplsLdpEntityIndex 78.5.1.1.2.1.1.2
This index is used as a secondary index to uniquely identify this row. Before creating a row in this table, the 'mplsLdpEntityIndexNext' object should be retrieved. That value should be used for the value of this index when creating a row in this table. NOTE: if a value of zero (0) is retrieved, that indicates that no rows can be created in this table at this time. A secondary index (this object) is meaningful to some but not all, LDP implementations. For example an LDP implementation which uses PPP would use this index to differentiate PPP sub-links. Another way to use this index is to give this the value of ifIndex. However, this is dependant on the implementation. This field is deprecated in the following tables provided by PRVT-CR-LDP Session Controller. - mplsLdpEntityTable. - mplsLdpPeerTable. In these tables the value of the Entity Index will always be filled in to be 1.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

mplsLdpEntityProtocolVersion 78.5.1.1.2.1.1.3
The version number of the protocol. The value of 0 on a read indicates that the version of the protocol is unknown. Otherwise, the value of this object represents the version of the LDP protocol. Section 3.5.3 in the LDP Specification specifies that the version of the LDP protocol is negotiated during session establishment. The value of this object represents the value that is sent in the initialization message.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..65535  

mplsLdpEntityAdminStatus 78.5.1.1.2.1.1.4
The administrative status of this LDP Entity. If this object is changed from 'enable' to 'disable' and this entity has already attempted to establish contact with a Peer (which implies that the 'mplsLdpEntityRowStatus' object has been set to 'active'), then all contact with that Peer is lost and all information from that Peer needs to be removed from the MIB. (This implies that the network management subsystem should clean up any related entry in the mplsLdpPeerTable. This further implies that a 'tear-down' for that session is issued and the session and all information related to that session cease to exist). At this point the user is able to change values which are related to this entity. When the admin status is set back to 'enable', then this Entity will attempt to establish a new session with the Peer.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

mplsLdpEntityOperStatus 78.5.1.1.2.1.1.5
The operational status of this LDP Entity. The value of unknown(1) indicates that the operational status cannot be determined at this time. The value of unknown should be a transient condition before changing to enabled(2) or disabled(3).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), enabled(2), disabled(3)  

mplsLdpEntityWellKnownTcpDiscoveryPort 78.5.1.1.2.1.1.6
The TCP Port for LDP. The default value is the well-known value of this port.
Status: current Access: read-create
OBJECT-TYPE    
  InetPortNumber  

mplsLdpEntityWellKnownUdpDiscoveryPort 78.5.1.1.2.1.1.7
The UDP Discovery Port for LDP. The default value is the well-known value for this port.
Status: current Access: read-create
OBJECT-TYPE    
  InetPortNumber  

mplsLdpEntityMaxPduLength 78.5.1.1.2.1.1.8
The maximum PDU Length that is sent in the Common Session Parameters of an Initialization Message. According to the LDP Specification [RFC3036] a value of 255 or less specifies the default maximum length of 4096 octets, this is why the value of this object starts at 256. The receiving LSR MUST calculate the maximum PDU length for the session by using the smaller of its and its peer's proposals for Max PDU Length.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 256..65535  

mplsLdpEntityKeepAliveHoldTimer 78.5.1.1.2.1.1.9
The 16-bit integer value which is the proposed keep alive hold timer for this LDP Entity.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 1..65535  

mplsLdpEntityHelloHoldTimer 78.5.1.1.2.1.1.10
The 16-bit integer value which is the proposed Hello hold timer for this LDP Entity. The Hello Hold time in seconds. An LSR maintains a record of Hellos received from potential peers. This object represents the Hold Time in the Common Hello Parameters TLV of the Hello Message. A value of 0 is a default value and should be interpretted in conjunction with the mplsLdpEntityTargetPeer object. If the value of this object is 0: if the value of the mplsLdpEntityTargetPeer object is false(2), then this specifies that the Hold Time's actual default value is 15 seconds (i.e., the default Hold time for Link Hellos is 15 seconds). Otherwise if the value of the mplsLdpEntityTargetPeer object is true(1), then this specifies that the Hold Time's actual default value is 45 seconds (i.e., the default Hold time for Targeted Hellos is 45 seconds). A value of 65535 means infinite (i.e., wait forever). All other values represent the amount of time in seconds to wait for a Hello Message. Setting the hold time to a value smaller than 15 is not recommended, although not forbidden according to RFC3036. For auto-created entities that use the global label space (and therefore might correspond to more than one adjacency over more than one interface), this value will only be meaningful if all interfaces that correspond to this entity are configured to use the same hello hold time, since this property can be configured on a per interface basis. If the interfaces have differing configurations, the value returned on a MIB Get will be 0.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..65535  

mplsLdpEntityInitSessionThreshold 78.5.1.1.2.1.1.11
When attempting to establish a session with a given Peer, the given LDP Entity should send out the SNMP notification, 'mplsLdpInitSessionThresholdExceeded', when the number of Session Initialization messages sent exceeds this threshold. The notification is used to notify an operator when this Entity and its Peer are possibly engaged in an endless sequence of messages as each NAKs the other's Initialization messages with Error Notification messages. Setting this threshold which triggers the notification is one way to notify the operator. The notification should be generated each time this threshold is exceeded and for every subsequent Initialization message which is NAK'd with an Error Notification message after this threshold is exceeded. A value of 0 (zero) for this object indicates that the threshold is infinity, thus the SNMP notification will never be generated.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..100  

mplsLdpEntityLabelDistMethod 78.5.1.1.2.1.1.12
For any given LDP session, the method of label distribution must be specified.
Status: current Access: read-create
OBJECT-TYPE    
  MplsLabelDistributionMethod  

mplsLdpEntityLabelRetentionMode 78.5.1.1.2.1.1.13
The LDP Entity can be configured to use either conservative or liberal label retention mode. If the value of this object is conservative(1) then advertized label mappings are retained only if they will be used to forward packets, i.e., if label came from a valid next hop. If the value of this object is liberal(2) then all advertized label mappings are retained whether they are from a valid next hop or not.
Status: current Access: read-create
OBJECT-TYPE    
  MplsRetentionMode  

mplsLdpEntityPathVectorLimit 78.5.1.1.2.1.1.14
If the value of this object is 0 (zero) then Loop Detection for Path Vectors is disabled. Otherwise, if this object has a value greater than zero, then Loop Dection for Path Vectors is enabled, and the Path Vector Limit is this value. Also, the value of the object, 'mplsLdpLsrLoopDetectionCapable', must be set to either 'pathVector(4)' or 'hopCountAndPathVector(5)', if this object has a value greater than 0 (zero), otherwise it is ignored.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

mplsLdpEntityHopCountLimit 78.5.1.1.2.1.1.15
If the value of this object is 0 (zero), then Loop Detection using Hop Counters is disabled. If the value of this object is greater than 0 (zero) then Loop Detection using Hop Counters is enabled, and this object specifies this Entity's maximum allowable value for the Hop Count. Also, the value of the object mplsLdpLsrLoopDetectionCapable must be set to either 'hopCount(3)' or 'hopCountAndPathVector(5)' if this object has a value greater than 0 (zero), otherwise it is ignored.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

mplsLdpEntityTransportAddrKind 78.5.1.1.2.1.1.16
This specifies whether the loopback or interface address is to be used as the transport address in the transport address TLV of the hello message. If the value is interface(1), then the IP address of the interface from which hello messages are sent is used as the transport address in the hello message. Otherwise, if the value is loopback(2), then the IP address of the loopback interface is used as the transport address in the hello message.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER interface(1), loopback(2)  

mplsLdpEntityTargetPeer 78.5.1.1.2.1.1.17
If this LDP entity uses targeted peer then set this to true.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

mplsLdpEntityTargetPeerAddrType 78.5.1.1.2.1.1.18
The type of the internetwork layer address used for the Extended Discovery. This object indicates how the value of mplsLdpEntityTargetPeerAddr is to be interpreted.
Status: current Access: read-create
OBJECT-TYPE    
  InetAddressType  

mplsLdpEntityTargetPeerAddr 78.5.1.1.2.1.1.19
The value of the internetwork layer address used for the Extended Discovery. The value of mplsLdpEntityTargetPeerAddrType specifies how this address is to be interpreted.
Status: current Access: read-create
OBJECT-TYPE    
  InetAddress  

mplsLdpEntityLabelType 78.5.1.1.2.1.1.20
Specifies the optional parameters for the LDP Initialization Message. If the value is generic(1) then no optional parameters will be sent in the LDP Initialization message associated with this Entity. If the value is atmParameters(2) then a row must be created in the mplsLdpEntityAtmTable, which corresponds to this entry. If the value is frameRelayParameters(3) then a row must be created in the mplsLdpEntityFrameRelayTable, which corresponds to this entry.
Status: current Access: read-create
OBJECT-TYPE    
  MplsLdpLabelType  

mplsLdpEntityDiscontinuityTime 78.5.1.1.2.1.1.21
The value of sysUpTime on the most recent occasion at which any one or more of this entity's counters suffered a discontinuity. The relevant counters are the specific instances associated with this entity of any Counter32 object contained in the 'mplsLdpEntityStatsTable'. If no such discontinuities have occurred since the last re-initialization of the local management subsystem, then this object contains a zero value.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

mplsLdpEntityStorageType 78.5.1.1.2.1.1.22
The storage type for this conceptual row. Conceptual rows having the value 'permanent(4)' need not allow write-access to any columnar objects in the row.
Status: current Access: read-only
OBJECT-TYPE    
  StorageType  

mplsLdpEntityRowStatus 78.5.1.1.2.1.1.25
An object that allows entries in this table to be created and deleted using the RowStatus convention. Once the 'mplsLdpEntityAdminStatus' object has the value of 'up' and this object has the value of 'active' then the Entity will atttempt to contact an LDP Peer. If the value of this object is changed to 'notInService', then the Entity looses contact with the LDP Peer and all information related to that Peer must be removed from the MIB. This has the same effect as changing 'mplsLdpEntityAdminStatus' from 'enable' to 'disable'. When this object is set to 'active' and the value of the 'mplsLdpEntityAdminStatus' is 'enable' then this Entity will attempt to contact the Peer and establish new sessions.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

mplsLdpEntityWildcardEntity 78.5.1.1.2.1.1.24
Specifies whether the LDP Entity is to be used for accepting 'unsolicited' Hello messages that include the R bit. The value of this object is ignored unless mplsLdpEntityTargetedPeer is set to true mplsLdpEntityTargetedPeerAddr is set to 0.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

mplsLdpEntityStatsTable 78.5.1.1.2.4
This table is a read-only table which augments the mplsLdpEntityTable. The purpose of this table is to keep statistical information about the LDP Entities on the LSR.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MplsLdpEntityStatsEntry

mplsLdpEntityStatsEntry 78.5.1.1.2.4.1
A row in this table contains statistical information about an LDP Entity. Some counters contained in a row are for fatal errors received during a former LDP Session associated with this entry. For example, an LDP PDU received on a TCP connection during an LDP Session contains a fatal error. That error is counted here, because the session is terminated. If the error is NOT fatal (i.e., the Session remains), then the error is counted in the mplsLdpSessionStatsEntry.
Status: current Access: not-accessible
OBJECT-TYPE    
  MplsLdpEntityStatsEntry  

mplsLdpEntityStatsSessionAttempts 78.5.1.1.2.4.1.1
A count of the Session Initialization messages which were sent or received by this LDP Entity and were NAK'd. In other words, this counter counts the number of session initializations that failed. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of mplsLdpEntityDiscontinuityTime.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

mplsLdpEntityStatsSessionRejectedNoHelloErrors 78.5.1.1.2.4.1.2
A count of the Session Rejected/No Hello Error Notification Messages sent or received by this LDP Entity. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of mplsLdpEntityDiscontinuityTime.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

mplsLdpEntityStatsSessionRejectedAdErrors 78.5.1.1.2.4.1.3
A count of the Session Rejected/Parameters Advertisement Mode Error Notification Messages sent or received by this LDP Entity. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of mplsLdpEntityDiscontinuityTime.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

mplsLdpEntityStatsSessionRejectedMaxPduErrors 78.5.1.1.2.4.1.4
A count of the Session Rejected/Parameters Max Pdu Length Error Notification Messages sent or received by this LDP Entity. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of mplsLdpEntityDiscontinuityTime.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

mplsLdpEntityStatsSessionRejectedLRErrors 78.5.1.1.2.4.1.5
A count of the Session Rejected/Parameters Label Range Notification Messages sent or received by this LDP Entity. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of mplsLdpEntityDiscontinuityTime.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

mplsLdpEntityStatsBadLdpIdentifierErrors 78.5.1.1.2.4.1.6
This object counts the number of Bad LDP Identifier Fatal Errors detected by the session(s) (past and present) associated with this LDP Entity. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of mplsLdpEntityDiscontinuityTime.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

mplsLdpEntityStatsBadPduLengthErrors 78.5.1.1.2.4.1.7
This object counts the number of Bad PDU Length Fatal Errors detected by the session(s) (past and present) associated with this LDP Entity. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of mplsLdpEntityDiscontinuityTime.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

mplsLdpEntityStatsBadMessageLengthErrors 78.5.1.1.2.4.1.8
This object counts the number of Bad Message Length Fatal Errors detected by the session(s) (past and present) associated with this LDP Entity. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of mplsLdpEntityDiscontinuityTime.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

mplsLdpEntityStatsBadTlvLengthErrors 78.5.1.1.2.4.1.9
This object counts the number of Bad TLV Length Fatal Errors detected by the session(s) (past and present) associated with this LDP Entity. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of mplsLdpEntityDiscontinuityTime.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

mplsLdpEntityStatsMalformedTlvValueErrors 78.5.1.1.2.4.1.10
This object counts the number of Malformed TLV Value Fatal Errors detected by the session(s) (past and present) associated with this LDP Entity. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of mplsLdpEntityDiscontinuityTime.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

mplsLdpEntityStatsKeepAliveTimerExpErrors 78.5.1.1.2.4.1.11
This object counts the number of Session Keep Alive Timer Expired Errors detected by the session(s) (past and present) associated with this LDP Entity. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of mplsLdpEntityDiscontinuityTime.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

mplsLdpEntityStatsShutdownReceivedNotifications 78.5.1.1.2.4.1.12
This object counts the number of Shutdown Notifications received related to session(s) (past and present) associated with this LDP Entity. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of mplsLdpEntityDiscontinuityTime.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

mplsLdpEntityStatsShutdownSentNotifications 78.5.1.1.2.4.1.13
This object counts the number of Shutdown Notfications sent related to session(s) (past and present) associated with this LDP Entity. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of mplsLdpEntityDiscontinuityTime.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

mplsLdpSessionObjects 78.5.1.1.3
OBJECT IDENTIFIER    

mplsLdpPeerLastChange 78.5.1.1.3.1
The value of sysUpTime at the time of the most recent addition or deletion to/from the mplsLdpPeerTable/mplsLdpSessionTable.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

mplsLdpPeerTable 78.5.1.1.3.2
Information about LDP peers known by Entities in the mplsLdpEntityTable. The information in this table is based on information from the Entity-Peer interaction during session initialization but is not appropriate for the mplsLdpSessionTable, because objects in this table may or may not be used in session establishment.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MplsLdpPeerEntry

mplsLdpPeerEntry 78.5.1.1.3.2.1
Information about a single Peer which is related to a Session. NOTE: this table is used to augment the mplsLdpSessionTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  MplsLdpPeerEntry  

mplsLdpPeerLdpId 78.5.1.1.3.2.1.1
The LDP identifier of this LDP Peer.
Status: current Access: not-accessible
OBJECT-TYPE    
  MplsLdpIdentifier  

mplsLdpPeerLabelDistMethod 78.5.1.1.3.2.1.2
For any given LDP session, the method of label distribution must be specified.
Status: current Access: read-only
OBJECT-TYPE    
  MplsLabelDistributionMethod  

mplsLdpPeerPathVectorLimit 78.5.1.1.3.2.1.3
If the value of this object is 0 (zero) then Loop Dection for Path Vectors for this Peer is disabled. Otherwise, if this object has a value greater than zero, then Loop Dection for Path Vectors for this Peer is enabled and the Path Vector Limit is this value.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

mplsLdpPeerTransportAddrType 78.5.1.1.3.2.1.4
The type of the Internet address for the mplsLdpPeerTransportAddr object. The LDP specification describes this as being either an IPv4 Transport Address or IPv6 Transport Address which is used in opening the LDP session's TCP connection, or if the optional TLV is not present, then this is the IPv4/IPv6 source address for the UPD packet carrying the Hellos. This object specifies how the value of the mplsLdpPeerTransportAddr object should be interpreted.
Status: current Access: read-only
OBJECT-TYPE    
  InetAddressType  

mplsLdpPeerTransportAddr 78.5.1.1.3.2.1.5
The Internet address advertised by the peer in the Hello Message or the Hello source address. The type of this address is specified by the value of the mplsLdpPeerTransportAddrType object.
Status: current Access: read-only
OBJECT-TYPE    
  InetAddress  

mplsLdpSessionTable 78.5.1.1.3.3
A table of Sessions between the LDP Entities and LDP Peers. Each row in this table represents a single session.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MplsLdpSessionEntry

mplsLdpSessionEntry 78.5.1.1.3.3.1
An entry in this table represents information on a single session between an LDP Entity and LDP Peer. The information contained in a row is read-only. Please note: the Path Vector Limit for the Session is the value which is configured in the corresponding mplsLdpEntityEntry. The Peer's Path Vector Limit is in the mplsLdpPeerPathVectorLimit object in the mplsLdpPeerTable. Values which may differ from those configured are noted in the objects of this table, the mplsLdpAtmSessionTable and the mplsLdpFrameRelaySessionTable. A value will differ if it was negotiated between the Entity and the Peer. Values may or may not be negotiated. For example, if the values are the same then no negotiation takes place. If they are negotiated, then they may differ.
Status: current Access: not-accessible
OBJECT-TYPE    
  MplsLdpSessionEntry  

mplsLdpSessionStateLastChange 78.5.1.1.3.3.1.1
The value of sysUpTime at the time this Session entered its current state as denoted by the mplsLdpSessionState object.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

mplsLdpSessionState 78.5.1.1.3.3.1.2
The current state of the session, all of the states 1 - 5 are based on the state machine for session negotiation behavior.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER nonexistent(1), initialized(2), openrec(3), opensent(4), operational(5)  

mplsLdpSessionRole 78.5.1.1.3.3.1.3
During session establishment the LSR/LER takes either the active role or the passive role based on address comparisons. This object indicates whether this LSR/LER was behaving in an active role or passive role during this session's establishment. The value of unknown(1), indicates that the role is not able to be determined at the present time.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), active(2), passive(3)  

mplsLdpSessionProtocolVersion 78.5.1.1.3.3.1.4
The version of the LDP Protocol which this session is using. This is the version of the LDP protocol which has been negotiated during session initialization.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..65535  

mplsLdpSessionKeepAliveHoldTimeRemaining 78.5.1.1.3.3.1.5
The keep alive hold time remaining for this session in units of hundredths of a second. This interval will change when the 'next' Keep Alive message which corresponds to this session is received. A value of zero indicates that the keep alive hold timer is not running.
Status: current Access: read-only
OBJECT-TYPE    
  TimeInterval  

mplsLdpSessionKeepAliveTime 78.5.1.1.3.3.1.6
The negotiated KeepAlive Time which represents the amount of seconds between keep alive messages. The mplsLdpEntityKeepAliveHoldTimer related to this Session is the value that was proposed as the KeepAlive Time for this session. This value is negotiated during session initialization between the entity's proposed value (i.e., the value configured in mplsLdpEntityKeepAliveHoldTimer) and the peer's proposed KeepAlive Hold Timer value. This value is the smaller of the two proposed values.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 1..65535  

mplsLdpSessionMaxPduLength 78.5.1.1.3.3.1.7
The value of maximum allowable length for LDP PDUs for this session. This value may have been negotiated during the Session Initialization. This object is related to the mplsLdpEntityMaxPduLength object. The mplsLdpEntityMaxPduLength object specifies the requested LDP PDU length, and this object reflects the negotiated LDP PDU length between the Entity and the Peer.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 1..65535  

mplsLdpSessionDiscontinuityTime 78.5.1.1.3.3.1.8
The value of sysUpTime on the most recent occasion at which any one or more of this session's counters suffered a discontinuity. The relevant counters are the specific instances associated with this session of any Counter32 or Counter64 object contained in the mplsLdpSessionStatsTable. If no such discontinuities have occurred since the last re-initialization of the local management subsystem, then this object contains a zero value. The initial value of this object is the value of sysUpTime when the entry was created in this table. Also, a NMS(command generator) can distinguish when a session between a given Entity and Peer goes away and then a new session is established. This value would change and thus indicate to the NMS(command generator) that this is a different session.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

mplsLdpSessionConfiguredHoldTime 78.5.1.1.3.3.1.13
The locally configured keepalive hold time for this session, in seconds. Note that the value of this field reflects configuration at the time of session initialization; this may differ from the configuration that would apply to a new session, if configuration has changed since this session was initialized.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

mplsLdpSessionPeerHoldTime 78.5.1.1.3.3.1.14
The peer's advertised keepalive hold time for this session in seconds. Note that the value of this field reflects the peer's configuration at the time of session initialization; this may differ from the configuration that would apply to a new session, if the peer's configuration has changed since this session was initialized.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

mplsLdpSessionHoldTimeInUse 78.5.1.1.3.3.1.15
The keepalive hold time that is currently in use for this session, in seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

mplsLdpSessionStatsTable 78.5.1.1.3.4
A table of statistics for Sessions between LDP Entities and LDP Peers. The table is read only. Counters are only incremented when the U bit is not set.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MplsLdpSessionStatsEntry

mplsLdpSessionStatsEntry 78.5.1.1.3.4.1
An entry in this table represents statistical information on a single session between an LDP Entity and LDP Peer. Errors are only counted if the U bit is not set in the message or TLV.
Status: current Access: not-accessible
OBJECT-TYPE    
  MplsLdpSessionStatsEntry  

mplsLdpSessionStatsUnknownMesTypeErrors 78.5.1.1.3.4.1.1
This object counts the number of Unknown Message Type Errors detected by this LSR/LER during this session. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of mplsLdpSessionDiscontinuityTime.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

mplsLdpSessionStatsUnknownTlvErrors 78.5.1.1.3.4.1.2
This object counts the number of Unknown TLV Errors detected by this LSR/LER during this session. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of mplsLdpSessionDiscontinuityTime.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

mplsLdpHelloAdjacencyObjects 78.5.1.1.3.5
OBJECT IDENTIFIER    

mplsLdpHelloAdjacencyTable 78.5.1.1.3.5.1
A table of Hello Adjacencies for Sessions.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MplsLdpHelloAdjacencyEntry

mplsLdpHelloAdjacencyEntry 78.5.1.1.3.5.1.1
Each row represents a single LDP Hello Adjacency. An LDP Session can have one or more Hello adjacencies.
Status: current Access: not-accessible
OBJECT-TYPE    
  MplsLdpHelloAdjacencyEntry  

mplsLdpHelloAdjacencyIndex 78.5.1.1.3.5.1.1.1
An identifier for this specific adjacency.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..4294967295  

mplsLdpHelloAdjacencyHoldTimeRemaining 78.5.1.1.3.5.1.1.2
If the value of this object is 65535, this means that the hold time is infinite (i.e., wait forever). Otherwise, the time remaining for this Hello Adjacency to receive its next Hello Message. This interval will change when the 'next' Hello Message which corresponds to this Hello Adjacency is received unless it is infinite.
Status: current Access: read-only
OBJECT-TYPE    
  TimeInterval  

mplsLdpHelloAdjacencyHoldTime 78.5.1.1.3.5.1.1.3
The Hello hold time which is negotiated between the Entity and the Peer. The entity associated with this Hello Adjacency issues a proposed Hello Hold Time value in the mplsLdpEntityHelloHoldTimer object. The peer also proposes a value and this object represents the negotiated value. A value of 0 means the default, which is 15 seconds for Link Hellos and 45 seconds for Targeted Hellos. A value of 65535 indicates an infinite hold time.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

mplsLdpHelloAdjacencyType 78.5.1.1.3.5.1.1.4
This adjacency is the result of a 'link' hello if the value of this object is link(1). Otherwise, it is a result of a 'targeted' hello, targeted(2).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER link(1), targeted(2)  

mplsLdpHelloAdjacencyConfiguredHoldTime 78.5.1.1.3.5.1.1.5
The locally configured hello hold time for this adjacency, in seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

mplsLdpHelloAdjacencyPeerHoldTime 78.5.1.1.3.5.1.1.6
The peer's advertised hello hold time for this adjacency, in seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

mplsInSegmentLdpLspTable 78.5.1.1.3.6
A table of LDP LSPs which map to the mplsInSegmentTable in the MPLS-LSR-MIB module.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MplsInSegmentLdpLspEntry

mplsInSegmentLdpLspEntry 78.5.1.1.3.6.1
An entry in this table represents information on a single LDP LSP which is represented by a session's index triple (mplsLdpEntityLdpId, mplsLdpEntityIndex, mplsLdpPeerLdpId) AND the index for the mplsInSegmentTable (mplsInSegmentLdpLspLabelIndex) from the MPLS-LSR-MIB. The information contained in a row is read-only.
Status: current Access: not-accessible
OBJECT-TYPE    
  MplsInSegmentLdpLspEntry  

mplsInSegmentLdpLspIndex 78.5.1.1.3.6.1.1
This contains the same value as the mplsInSegmentIndex in the MPLS-LSR-MIB's mplsInSegmentTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  MplsIndexType  

mplsInSegmentLdpLspLabelType 78.5.1.1.3.6.1.2
The Layer 2 Label Type.
Status: current Access: read-only
OBJECT-TYPE    
  MplsLdpLabelType  

mplsInSegmentLdpLspType 78.5.1.1.3.6.1.3
The type of LSP connection.
Status: current Access: read-only
OBJECT-TYPE    
  MplsLspType  

mplsOutSegmentLdpLspTable 78.5.1.1.3.7
A table of LDP LSPs which map to the mplsOutSegmentTable in the MPLS-LSR-MIB.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MplsOutSegmentLdpLspEntry

mplsOutSegmentLdpLspEntry 78.5.1.1.3.7.1
An entry in this table represents information on a single LDP LSP which is represented by a session's index triple (mplsLdpEntityLdpId, mplsLdpEntityIndex, mplsLdpPeerLdpId) AND the index (mplsOutSegmentLdpLspIndex) for the mplsOutSegmentTable. The information contained in a row is read-only.
Status: current Access: not-accessible
OBJECT-TYPE    
  MplsOutSegmentLdpLspEntry  

mplsOutSegmentLdpLspIndex 78.5.1.1.3.7.1.1
This contains the same value as the mplsOutSegmentIndex in the MPLS-LSR-MIB's mplsOutSegmentTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  MplsIndexType  

mplsOutSegmentLdpLspLabelType 78.5.1.1.3.7.1.2
The Layer 2 Label Type.
Status: current Access: read-only
OBJECT-TYPE    
  MplsLdpLabelType  

mplsOutSegmentLdpLspType 78.5.1.1.3.7.1.3
The type of LSP connection.
Status: current Access: read-only
OBJECT-TYPE    
  MplsLspType  

mplsFecObjects 78.5.1.1.3.10
OBJECT IDENTIFIER    

mplsFecLastChange 78.5.1.1.3.10.1
The value of sysUpTime at the time of the most recent addition/deletion of an entry to/from the mplsLdpFectTable or the most recent change in values to any objects in the mplsLdpFecTable. If no such changes have occurred since the last re-initialization of the local management subsystem, then this object contains a zero value.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

mplsFecTable 78.5.1.1.3.10.2
This table represents the FEC (Forwarding Equivalence Class) Information associated with an LSP.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MplsFecEntry

mplsFecEntry 78.5.1.1.3.10.2.1
Each row represents a single FEC Element.
Status: current Access: not-accessible
OBJECT-TYPE    
  MplsFecEntry  

mplsFecIndex 78.5.1.1.3.10.2.1.1
The index which uniquely identifies this entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..4294967295  

mplsFecType 78.5.1.1.3.10.2.1.2
The type of the FEC. If the value of this object is 'prefix(1)' then the FEC type described by this row is an address prefix. If the value of this object is 'hostAddress(2)' then the FEC type described by this row is a host address.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER prefix(1), hostAddress(2)  

mplsFecAddrType 78.5.1.1.3.10.2.1.4
The value of this object is the type of the Internet address. The value of this object, decides how the value of the mplsFecAddr object is interpreted.
Status: current Access: read-only
OBJECT-TYPE    
  InetAddressType  

mplsFecAddr 78.5.1.1.3.10.2.1.5
The value of this object is interpreted based on the value of the 'mplsFecAddrType' object. This address is then further interpretted as an being used with the address prefix, or as the host address. This further interpretation is indicated by the 'mplsFecType' object. In other words, the FEC element is populated according to the Prefix FEC Element value encoding, or the Host Address FEC Element encoding.
Status: current Access: read-only
OBJECT-TYPE    
  InetAddress  

mplsFecAddrPrefixLength 78.5.1.1.3.10.2.1.3
If the value of the 'mplsFecType' is 'hostAddress(2)' then this object is undefined. If the value of 'mplsFecType' is 'prefix(1)' then the value of this object is the length in bits of the address prefix represented by 'mplsFecAddr', or zero. If the value of this object is zero, this indicates that the prefix matches all addresses. In this case the address prefix MUST also be zero (i.e., 'mplsFecAddr' should have the value of zero).
Status: current Access: read-only
OBJECT-TYPE    
  InetAddressPrefixLength  

mplsFecStorageType 78.5.1.1.3.10.2.1.6
The storage type for this conceptual row. Conceptual rows having the value 'permanent(4)' need not allow write-access to any columnar objects in the row.
Status: current Access: read-only
OBJECT-TYPE    
  StorageType  

mplsLdpLspFecLastChange 78.5.1.1.3.11
The value of sysUpTime at the time of the most recent addition/deletion of an entry to/from the mplsLdpLspFecTable or the most recent change in values to any objects in the mplsLdpLspFecTable. If no such changes have occurred since the last re-initialization of the local management subsystem, then this object contains a zero value.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

mplsLdpLspFecTable 78.5.1.1.3.12
A table which shows the relationship between LDP LSPs and FECs. Each row represents a single LDP LSP to FEC association.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MplsLdpLspFecEntry

mplsLdpLspFecEntry 78.5.1.1.3.12.1
An entry represents a LDP LSP to FEC association.
Status: current Access: not-accessible
OBJECT-TYPE    
  MplsLdpLspFecEntry  

mplsLdpLspFecSegment 78.5.1.1.3.12.1.1
If the value is inSegment(1), then this indicates that the following index, mplsLdpLspFecSegmentIndex, contains the same value as the mplsInSegmentLdpLspIndex. Otherwise, if the value of this object is outSegment(2), then this indicates that following index, mplsLdpLspFecSegmentIndex, contains the same value as the mplsOutSegmentLdpLspIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER inSegment(1), outSegment(2)  

mplsLdpLspFecSegmentIndex 78.5.1.1.3.12.1.2
This index is interpretted by using the value of the mplsLdpLspFecSegment. If the mplsLdpLspFecSegment is inSegment(1), then this index has the same value as mplsInSegmentLdpLspIndex. If the mplsLdpLspFecSegment is outSegment(2), then this index has the same value as mplsOutSegmentLdpLspIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  MplsIndexType  

mplsLdpLspFecIndex 78.5.1.1.3.12.1.3
This index identifies the FEC entry in the mplsFecTable associated with this session. In other words, the value of this index is the same as the value of the mplsFecIndex that denotes the FEC associated with this Session.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..2147483647  

mplsLdpLspFecStorageType 78.5.1.1.3.12.1.4
The storage type for this conceptual row. Conceptual rows having the value 'permanent(4)' need not allow write-access to any columnar objects in the row.
Status: current Access: read-create
OBJECT-TYPE    
  StorageType  

mplsLdpLspFecRowStatus 78.5.1.1.3.12.1.5
The status of this conceptual row. If the value of this object is 'active(1)', then none of the writable objects of this entry can be modified. The Agent should delete this row when the session ceases to exist. If an operator wants to associate the session with a different FEC, the recommended procedure is (as described in detail in the section entitled, 'Changing Values After Session Establishment', and again described in the DESCRIPTION clause of the mplsLdpEntityAdminStatus object) is to set the mplsLdpEntityAdminStatus to down, thereby explicitly causing a session to be torn down. This will also cause this entry to be deleted. Then, set the mplsLdpEntityAdminStatus to enable which enables a new session to be initiated. Once the session is initiated, an entry may be added to this table to associate the new session with a FEC.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

mplsLdpSessionPeerAddrTable 78.5.1.1.3.13
This table 'extends' the mplsLdpSessionTable. This table is used to store Label Address Information from Label Address Messages received by this LSR from Peers. This table is read-only and should be updated when Label Withdraw Address Messages are received, i.e., Rows should be deleted as appropriate. NOTE: since more than one address may be contained in a Label Address Message, this table 'sparse augments', the mplsLdpSessionTable's information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MplsLdpSessionPeerAddrEntry

mplsLdpSessionPeerAddrEntry 78.5.1.1.3.13.1
An entry in this table represents information on a session's single next hop address which was advertised in an Address Message from the LDP peer. The information contained in a row is read-only.
Status: current Access: not-accessible
OBJECT-TYPE    
  MplsLdpSessionPeerAddrEntry  

mplsLdpSessionPeerAddrIndex 78.5.1.1.3.13.1.1
An index which uniquely identifies this entry within a given session.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..4294967295  

mplsLdpSessionPeerNextHopAddrType 78.5.1.1.3.13.1.2
The internetwork layer address type of this Next Hop Address as specified in the Label Address Message associated with this Session. The value of this object indicates how to interpret the value of mplsLdpSessionPeerNextHopAddr.
Status: current Access: read-only
OBJECT-TYPE    
  InetAddressType  

mplsLdpSessionPeerNextHopAddr 78.5.1.1.3.13.1.3
The next hop address. The type of this address is specified by the value of the mplsLdpSessionPeerNextHopAddrType.
Status: current Access: read-only
OBJECT-TYPE    
  InetAddress  

mplsLdpEntityIndexNextTable 78.5.1.1.2.2
This table contains the next available values of mplsLdpEntityIndex for all entities.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MplsLdpEntityIndexNextEntry

mplsLdpEntityIndexNextEntry 78.5.1.1.2.2.1
An entry in this table represents the next available mplsLdpEntityIndex for a specific LDP entity. This MIB table is indexed by the PRVT-LDP entity Index.
Status: current Access: not-accessible
OBJECT-TYPE    
  MplsLdpEntityIndexNextEntry  

mplsLdpEntityIndexNext 78.5.1.1.2.2.1.1
This object contains an appropriate value to be used for mplsLdpEntityIndex when creating entries in the mplsLdpEntityTable. The value 0 indicates that no unassigned entries are available. To obtain the mplsLdpEntityIndex value for a new entry, the manager issues a management protocol retrieval operation to obtain the current value of this object. After each retrieval, the agent should modify the value to the next unassigned index.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

mplsLdpInitSessionThresholdExceeded 78.5.1.2.0.1
This notification is generated when the value of the 'mplsLdpEntityInitSessionThreshold' object is not zero, and the number of Session Initialization messages exceeds the value of the 'mplsLdpEntityInitSessionThreshold' object.
Status: current Access: read-only
NOTIFICATION-TYPE    

mplsLdpPathVectorLimitMismatch 78.5.1.2.0.2
This notification is sent when the 'mplsLdpEntityPathVectorLimit' does NOT match the value of the 'mplsLdpPeerPathVectorLimit' for a specific Entity.
Status: current Access: read-only
NOTIFICATION-TYPE    

mplsLdpSessionUp 78.5.1.2.0.3
If this notification is sent when the value of 'mplsLdpSessionState' enters the 'operational(5)' state.
Status: current Access: read-only
NOTIFICATION-TYPE    

mplsLdpSessionDown 78.5.1.2.0.4
This notification is sent when the value of 'mplsLdpSessionState' leaves the 'operational(5)' state.
Status: current Access: read-only
NOTIFICATION-TYPE    

mplsLdpGroups 78.5.1.3.1
OBJECT IDENTIFIER    

mplsLdpCompliances 78.5.1.3.2
OBJECT IDENTIFIER    

mplsLdpModuleFullCompliance 78.5.1.3.2.1
The Module is implemented with support for read-create and read-write. In other words, both monitoring and configuration are available when using this MODULE-COMPLIANCE.
Status: current Access: read-only
MODULE-COMPLIANCE    

mplsLdpModuleReadOnlyCompliance 78.5.1.3.2.2
The Module is implemented with support for read-only. In other words, only monitoring is available by implementing this MODULE-COMPLIANCE.
Status: current Access: read-only
MODULE-COMPLIANCE    

mplsLdpGeneralGroup 78.5.1.3.1.1
Objects that apply to all MPLS LDP implementations.
Status: current Access: read-only
OBJECT-GROUP    

mplsLdpLspGroup 78.5.1.3.1.2
These objects are for LDP implementations which interface to the Label Information Base (LIB) in the MPLS-LSR-STD-MIB. The LIB is represented in the mplsInSegmentTable, mplsOutSegmentTable and mplsXCTable.
Status: current Access: read-only
OBJECT-GROUP    

mplsLdpNotificationsGroup 78.5.1.3.1.3
The notification for an MPLS LDP implementation.
Status: current Access: read-only
NOTIFICATION-GROUP    

mplsLdpAtmObjects 78.5.1.4
OBJECT IDENTIFIER    

mplsLdpAtmConformance 78.5.1.5
OBJECT IDENTIFIER    

mplsLdpEntityAtmObjects 78.5.1.4.1
OBJECT IDENTIFIER    

mplsLdpEntityAtmTable 78.5.1.4.1.1
This table contains ATM specific information which could be used in the 'Optional Parameters' and other ATM specific information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MplsLdpEntityAtmEntry

mplsLdpEntityAtmEntry 78.5.1.4.1.1.1
An entry in this table represents the ATM parameters and ATM information for this LDP entity.
Status: current Access: not-accessible
OBJECT-TYPE    
  MplsLdpEntityAtmEntry  

mplsLdpEntityAtmIfIndexOrZero 78.5.1.4.1.1.1.1
This value represents either the InterfaceIndex or 0 (zero). The value of zero means that the InterfaceIndex is not known. However, if the InterfaceIndex is known, then it must be represented by this value. If an InterfaceIndex becomes known, then the network management entity (e.g., SNMP agent) responsible for this object MUST change the value from 0 (zero) to the value of the InterfaceIndex. If an ATM Label is being used in forwarding data, then the value of this object MUST be the InterfaceIndex.
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndexOrZero  

mplsLdpEntityAtmMergeCap 78.5.1.4.1.1.1.2
Denotes the Merge Capability of this Entity. This is the EXACT value for the ATM Session Parameter, field M (for ATM Merge Capabilities). The ATM Session Parameter is an optional parameter in the Initialization Message. The description from rfc3036.txt is: 'M, ATM Merge Capabilities Specifies the merge capabilities of an ATM switch. The following values are supported in this version of the specification: Value Meaning 0 Merge not supported 1 VP Merge supported 2 VC Merge supported 3 VP & VC Merge supported If the merge capabilities of the LSRs differ, then: - Non-merge and VC-merge LSRs may freely interoperate. - The interoperability of VP-merge-capable switches with non-VP-merge-capable switches is a subject for future study. When the LSRs differ on the use of VP-merge, the session is established, but VP merge is not used.' Please refer to the following reference for a complete description of this feature.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notSupported(0), vpMerge(1), vcMerge(2), vpAndVcMerge(3)  

mplsLdpEntityAtmLRComponents 78.5.1.4.1.1.1.3
Number of Label Range Components in the Initialization message. This also represents the number of entries in the mplsLdpEntityAtmLRTable which correspond to this entry. This is the EXACT value for the ATM Session Parameter, field N (for Number of label range components). The ATM Session Parameter is an optional parameter in the Initialization Message. The description from rfc3036.txt is: 'N, Number of label range components Specifies the number of ATM Label Range Components included in the TLV.' Please refer to the following reference for a complete description of this feature.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 1..65535  

mplsLdpEntityAtmVcDirectionality 78.5.1.4.1.1.1.4
If the value of this object is 'bidirectional(0)', a given VCI, within a given VPI, is used as a label for both directions independently. If the value of this object is 'unidirectional(1)', a given VCI within a VPI designates one direction. This is the EXACT value for the ATM Session Parameter, field D (for VC Directionality). The ATM Session Parameter is an optional parameter in the Initialization Message. The description from rfc3036.txt is: 'D, VC Directionality A value of 0 specifies bidirectional VC capability, meaning the LSR can (within a given VPI) support the use of a given VCI as a label for both link directions independently. A value of 1 specifies unidirectional VC capability, meaning (within a given VPI) a given VCI may appear in a label mapping for one direction on the link only. When either or both of the peers specifies unidirectional VC capability, both LSRs use unidirectional VC label assignment for the link as follows. The LSRs compare their LDP Identifiers as unsigned integers. The LSR with the larger LDP Identifier may assign only odd-numbered VCIs in the VPI/VCI range as labels. The system with the smaller LDP Identifier may assign only even-numbered VCIs in the VPI/VCI range as labels.' Please refer to the following reference for a complete description of this feature.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER bidirectional(0), unidirectional(1)  

mplsLdpEntityAtmLsrConnectivity 78.5.1.4.1.1.1.5
The peer LSR may be connected indirectly by means of an ATM VP so that the VPI values may be different on either endpoint so the label MUST be encoded entirely within the VCI field.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER direct(1), indirect(2)  

mplsLdpEntityAtmDefaultControlVpi 78.5.1.4.1.1.1.6
The default VPI value for the non-MPLS connection. The default value of this is 0 (zero) but other values may be configured. This object allows a different value to be configured.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

mplsLdpEntityAtmDefaultControlVci 78.5.1.4.1.1.1.7
The Default VCI value for a non-MPLS connection. The default value of this is 32 but other values may be configured. This object allows a different value to be configured.
Status: current Access: read-only
OBJECT-TYPE    
  MplsAtmVcIdentifier  

mplsLdpEntityAtmUnlabTrafVpi 78.5.1.4.1.1.1.8
VPI value of the VCC supporting unlabeled traffic. This non-MPLS connection is used to carry unlabeled (IP) packets. The default value is the same as the default value of the 'mplsLdpEntityAtmDefaultControlVpi', however another value may be configured.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

mplsLdpEntityAtmUnlabTrafVci 78.5.1.4.1.1.1.9
VCI value of the VCC supporting unlabeled traffic. This non-MPLS connection is used to carry unlabeled (IP) packets. The default value is the same as the default value of the 'mplsLdpEntityAtmDefaultControlVci', however another value may be configured.
Status: current Access: read-only
OBJECT-TYPE    
  MplsAtmVcIdentifier  

mplsLdpEntityAtmStorageType 78.5.1.4.1.1.1.10
The storage type for this conceptual row. Conceptual rows having the value 'permanent(4)' need not allow write-access to any columnar objects in the row.
Status: current Access: read-only
OBJECT-TYPE    
  StorageType  

mplsLdpEntityAtmLRTable 78.5.1.4.1.2
The MPLS LDP Entity ATM Label Range (LR) Table. The purpose of this table is to provide a mechanism for configuring a contiguous range of vpi's with a contiguous range of vci's, or a 'label range' for LDP Entities. LDP Entities which use ATM must have at least one entry in this table. There must exist at least one entry in this table for every LDP Entity that has 'mplsLdpEntityLabelType' object with a value of 'atmSessionParameters'.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MplsLdpEntityAtmLREntry

mplsLdpEntityAtmLREntry 78.5.1.4.1.2.1
A row in the LDP Entity ATM Label Range Table. One entry in this table contains information on a single range of labels represented by the configured Upper and Lower Bounds VPI/VCI pairs. These are the same data used in the Initialization Message. NOTE: The ranges for a specific LDP Entity are UNIQUE and non-overlapping. For example, for a specific LDP Entity index, there could be one entry having LowerBound vpi/vci == 0/32, and UpperBound vpi/vci == 0/100, and a second entry for this same interface with LowerBound vpi/vci == 0/101 and UpperBound vpi/vci == 0/200. However, there could not be a third entry with LowerBound vpi/vci == 0/200 and UpperBound vpi/vci == 0/300 because this label range overlaps with the second entry (i.e., both entries now have 0/200). A row will not become active unless a unique and non-overlapping range is specified. At least one label range entry for a specific LDP Entity MUST include the default VPI/VCI values denoted in the LDP Entity Table. A request to create a row with an overlapping range should result in an inconsistentValue error.
Status: current Access: not-accessible
OBJECT-TYPE    
  MplsLdpEntityAtmLREntry  

mplsLdpEntityAtmLRMinVpi 78.5.1.4.1.2.1.1
The minimum VPI number configured for this range. The value of zero is a valid value for the VPI portion of the label.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..2147483647  

mplsLdpEntityAtmLRMinVci 78.5.1.4.1.2.1.2
The minimum VCI number configured for this range.
Status: current Access: not-accessible
OBJECT-TYPE    
  MplsAtmVcIdentifier  

mplsLdpEntityAtmLRMaxVpi 78.5.1.4.1.2.1.3
The maximum VPI number configured for this range.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

mplsLdpEntityAtmLRMaxVci 78.5.1.4.1.2.1.4
The maximum VCI number configured for this range.
Status: current Access: read-only
OBJECT-TYPE    
  MplsAtmVcIdentifier  

mplsLdpEntityAtmLRStorageType 78.5.1.4.1.2.1.5
The storage type for this conceptual row. Conceptual rows having the value 'permanent(4)' need not allow write-access to any columnar objects in the row.
Status: current Access: read-only
OBJECT-TYPE    
  StorageType  

mplsLdpAtmSessionObjects 78.5.1.4.2
OBJECT IDENTIFIER    

mplsLdpAtmSessionTable 78.5.1.4.2.1
A table which relates sessions in the 'mplsLdpSessionTable' and their label range intersections. There could be one or more label range intersections between an LDP Entity and LDP Peer using ATM as the underlying media. Each row represents a single label range intersection. This table cannot use the 'AUGMENTS' clause because there is not necessarily a one-to-one mapping between this table and the mplsLdpSessionTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MplsLdpAtmSessionEntry

mplsLdpAtmSessionEntry 78.5.1.4.2.1.1
An entry in this table represents information on a single label range intersection between an LDP Entity and LDP Peer. The information contained in a row is read-only.
Status: current Access: not-accessible
OBJECT-TYPE    
  MplsLdpAtmSessionEntry  

mplsLdpSessionAtmLRLowerBoundVpi 78.5.1.4.2.1.1.1
The minimum VPI number for this range.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..2147483647  

mplsLdpSessionAtmLRLowerBoundVci 78.5.1.4.2.1.1.2
The minimum VCI number for this range.
Status: current Access: not-accessible
OBJECT-TYPE    
  MplsAtmVcIdentifier  

mplsLdpSessionAtmLRUpperBoundVpi 78.5.1.4.2.1.1.3
The maximum VPI number for this range.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

mplsLdpSessionAtmLRUpperBoundVci 78.5.1.4.2.1.1.4
The maximum VCI number for this range.
Status: current Access: read-only
OBJECT-TYPE    
  MplsAtmVcIdentifier  

mplsLdpAtmGroups 78.5.1.5.1
OBJECT IDENTIFIER    

mplsLdpAtmCompliances 78.5.1.5.2
OBJECT IDENTIFIER    

mplsLdpAtmModuleFullCompliance 78.5.1.5.2.1
The Module is implemented with support for read-create and read-write. In other words, both monitoring and configuration are available when using this MODULE-COMPLIANCE.
Status: current Access: read-only
MODULE-COMPLIANCE    

mplsLdpAtmModuleReadOnlyCompliance 78.5.1.5.2.2
The Module is implemented with support for read-only. In other words, only monitoring is available by implementing this MODULE-COMPLIANCE.
Status: current Access: read-only
MODULE-COMPLIANCE    

mplsLdpAtmGroup 78.5.1.5.1.1
Objects that apply to all MPLS LDP implementations using ATM as the Layer 2.
Status: current Access: read-only
OBJECT-GROUP    

mplsLdpFrameRelayObjects 78.5.1.6
OBJECT IDENTIFIER    

mplsLdpFrameRelayConformance 78.5.1.7
OBJECT IDENTIFIER    

mplsLdpEntityFrameRelayObjects 78.5.1.6.1
OBJECT IDENTIFIER    

mplsLdpEntityFrameRelayTable 78.5.1.6.1.1
This table contains Frame Relay specific information which could be used in the 'Optional Parameters' and other Frame Relay specific information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MplsLdpEntityFrameRelayEntry

mplsLdpEntityFrameRelayEntry 78.5.1.6.1.1.1
An entry in this table represents the Frame Relay optional parameters associated with the LDP entity.
Status: current Access: not-accessible
OBJECT-TYPE    
  MplsLdpEntityFrameRelayEntry  

mplsLdpEntityFrameRelayIfIndexOrZero 78.5.1.6.1.1.1.1
This value represents either the InterfaceIndex of the 'ifLayer' where the Frame Relay Labels 'owned' by this entry were created, or 0 (zero). The value of zero means that the InterfaceIndex is not known. For example, if the InterfaceIndex is created subsequent to the Frame Relay Label's creation, then it would not be known. However, if the InterfaceIndex is known, then it must be represented by this value. If an InterfaceIndex becomes known, then the network management entity (e.g., SNMP agent) responsible for this object MUST change the value from 0 (zero) to the value of the InterfaceIndex. If an Frame Relay Label is being used in forwarding data, then the value of this object MUST be the InterfaceIndex.
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndexOrZero  

mplsLdpEntityFrameRelayMergeCap 78.5.1.6.1.1.1.2
This represents whether or not the Frame Relay merge capability is supported. This is the EXACT value for the Frame Relay Session Parameter, field M (for Frame Relay Merge Capabilities). The Frame Relay Session Parameter is an optional parameter in the Initialization Message. The description from rfc3036.txt is: 'M, Frame Relay Merge Capabilities Specifies the merge capabilities of a Frame Relay switch. The following values are supported in this version of the specification: Value Meaning 0 Merge not supported 1 Merge supported Non-merge and merge Frame Relay LSRs may freely interoperate.' Please refer to the following reference for a complete description of this feature.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notSupported(0), supported(1)  

mplsLdpEntityFrameRelayLRComponents 78.5.1.6.1.1.1.3
Number of Label Range Components in the Initialization message. This also represents the number of entries in the mplsLdpEntityFrameRelayLRTable which correspond to this entry. This is the EXACT value for the Frame Relay Session Parameter, field N (for Number of label range components). The Frame Relay Session Parameter is an optional parameter in the Initialization Message. The description from rfc3036.txt is: 'N, Number of label range components Specifies the number of Frame Relay Label Range Components included in the TLV.' Please refer to the following reference for a complete description of this feature.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 1..65535  

mplsLdpEntityFrameRelayVcDirectionality 78.5.1.6.1.1.1.4
If the value of this object is 'bidirectional(0)', then the LSR supports the use of a given DLCI as a label for both directions independently. If the value of this object is 'unidirectional(1)', then the LSR uses the given DLCI as a label in only one direction. This is the EXACT value for the Frame Relay Session Parameter, field D (for VC Directionality). The Frame Relay Session Parameter is an optional parameter in the Initialization Message. The description from rfc3036.txt is: 'D, VC Directionality A value of 0 specifies bidirectional VC capability, meaning the LSR can support the use of a given DLCI as a label for both link directions independently. A value of 1 specifies unidirectional VC capability, meaning a given DLCI may appear in a label mapping for one direction on the link only. When either or both of the peers specifies unidirectional VC capability, both LSRs use unidirectional VC label assignment for the link as follows. The LSRs compare their LDP Identifiers as unsigned integers. The LSR with the larger LDP Identifier may assign only odd-numbered DLCIs in the range as labels. The system with the smaller LDP Identifier may assign only even-numbered DLCIs in the range as labels.' Please refer to the following reference for a complete description of this feature.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER bidirectional(0), unidirection(1)  

mplsLdpEntityFrameRelayStorageType 78.5.1.6.1.1.1.5
The storage type for this conceptual row. Conceptual rows having the value 'permanent(4)' need not allow write-access to any columnar objects in the row.
Status: current Access: read-only
OBJECT-TYPE    
  StorageType  

mplsLdpEntityFrameRelayLRTable 78.5.1.6.1.2
This table contains information about the Optional Parameters for the Frame Relay Session in the LDP Initialization Message, specifically it contains information about the Frame Relay Label Range Components. If the value of the object 'mplsLdpEntityLabelType' contains the value of 'frameRelaySessionParameters(3)' then there must be at least one corresponding entry in this table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MplsLdpEntityFrameRelayLREntry

mplsLdpEntityFrameRelayLREntry 78.5.1.6.1.2.1
An entry in this table represents the Frame Relay Label Range Component associated with the LDP entity.
Status: current Access: not-accessible
OBJECT-TYPE    
  MplsLdpEntityFrameRelayLREntry  

mplsLdpEntityFrameRelayLRMinDlci 78.5.1.6.1.2.1.1
The lower bound which is supported. This value should be the same as that in the Frame Relay Label Range Component's Minimum DLCI field. The value of zero is valid for the minimum DLCI field of the label.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..2147483647  

mplsLdpEntityFrameRelayLRMaxDlci 78.5.1.6.1.2.1.2
The upper bound which is supported. This value should be the same as that in the Frame Relay Label Range Component's Maximum DLCI field.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

mplsLdpEntityFrameRelayLRLen 78.5.1.6.1.2.1.3
This object specifies the length of the DLCI bits. This is the EXACT value for the Len field of the Frame Relay Label Range Component. The description from rfc3036.txt is: 'Len This field specifies the number of bits of the DLCI. The following values are supported: Len DLCI bits 0 10 2 23 Len values 1 and 3 are reserved.' Please refer to the following reference for a complete description of this feature.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER tenDlciBits(0), twentyThreeDlciBits(2)  

mplsLdpEntityFrameRelayLRStorageType 78.5.1.6.1.2.1.4
The storage type for this conceptual row. Conceptual rows having the value 'permanent(4)' need not allow write-access to any columnar objects in the row.
Status: current Access: read-only
OBJECT-TYPE    
  StorageType  

mplsLdpFrameRelaySessionObjects 78.5.1.6.2
OBJECT IDENTIFIER    

mplsLdpFrameRelaySessionTable 78.5.1.6.2.1
A table of Frame Relay label range intersections between the LDP Entities and LDP Peers. Each row represents a single label range intersection. NOTE: this table cannot use the 'AUGMENTS' clause because there is not necessarily a one-to-one mapping between this table and the mplsLdpSessionTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MplsLdpFrameRelaySessionEntry

mplsLdpFrameRelaySessionEntry 78.5.1.6.2.1.1
An entry in this table represents information on a single label range intersection between an LDP Entity and LDP Peer. The information contained in a row is read-only.
Status: current Access: not-accessible
OBJECT-TYPE    
  MplsLdpFrameRelaySessionEntry  

mplsLdpFrameRelaySessionMinDlci 78.5.1.6.2.1.1.1
The lower bound of DLCIs which are supported. The value of zero is a valid value for the minimum DLCI field of the label.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..2147483647  

mplsLdpFrameRelaySessionMaxDlci 78.5.1.6.2.1.1.2
The upper bound of DLCIs which are supported.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

mplsLdpFrameRelaySessionLen 78.5.1.6.2.1.1.3
This object specifies the DLCI bits.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER tenDlciBits(0), twentyThreeDlciBits(2)  

mplsLdpFrameRelayGroups 78.5.1.7.1
OBJECT IDENTIFIER    

mplsLdpFrameRelayCompliances 78.5.1.7.2
OBJECT IDENTIFIER    

mplsLdpFrameRelayModuleReadOnlyCompliance 78.5.1.7.2.2
The Module is implemented with support for read-only. In other words, only monitoring is available by implementing this MODULE-COMPLIANCE.
Status: current Access: read-only
MODULE-COMPLIANCE    

mplsLdpFrameRelayGroup 78.5.1.7.1.1
Objects that apply to all MPLS LDP implementations using Frame Relay as the Layer 2.
Status: current Access: read-only
OBJECT-GROUP    

mplsLdpGenericObjects 78.5.1.8
OBJECT IDENTIFIER    

mplsLdpGenericConformance 78.5.1.9
OBJECT IDENTIFIER    

mplsLdpEntityGenericObjects 78.5.1.8.1
OBJECT IDENTIFIER    

mplsLdpEntityGenericLRTable 78.5.1.8.1.1
The MPLS LDP Entity Generic Label Range (LR) Table. The purpose of this table is to provide a mechanism for configurating a contiguous range of generic labels, or a 'label range' for LDP Entities. LDP Entities which use Generic Labels must have at least one entry in this table. In other words, this table 'extends' the mpldLdpEntityTable for Generic Labels.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MplsLdpEntityGenericLREntry

mplsLdpEntityGenericLREntry 78.5.1.8.1.1.1
A row in the LDP Entity Generic Label Range (LR) Table. One entry in this table contains information on a single range of labels represented by the configured Upper and Lower Bounds pairs. NOTE: there is NO corresponding LDP message which relates to the information in this table, however, this table does provide a way for a user to 'reserve' a generic label range. NOTE: The ranges for a specific LDP Entity are UNIQUE and non-overlapping. A row will not be created unless a unique and non-overlapping range is specified.
Status: current Access: not-accessible
OBJECT-TYPE    
  MplsLdpEntityGenericLREntry  

mplsLdpEntityGenericLRMin 78.5.1.8.1.1.1.1
The minimum label configured for this range.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..1048575  

mplsLdpEntityGenericLRMax 78.5.1.8.1.1.1.2
The maximum label configured for this range.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..1048575  

mplsLdpEntityGenericLabelSpace 78.5.1.8.1.1.1.3
This value of this object is perPlatform(1), then this means that the label space type is per platform. If this object is perInterface(2), then this means that the label space type is per Interface.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER perPlatform(1), perInterface(2)  

mplsLdpEntityGenericIfIndexOrZero 78.5.1.8.1.1.1.4
This value represents either the InterfaceIndex of the 'ifLayer' where these Generic Label would be created, or 0 (zero). The value of zero means that the InterfaceIndex is not known. However, if the InterfaceIndex is known, then it must be represented by this value. If an InterfaceIndex becomes known, then the network management entity (e.g., SNMP agent) responsible for this object MUST change the value from 0 (zero) to the value of the InterfaceIndex.
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndexOrZero  

mplsLdpEntityGenericLRStorageType 78.5.1.8.1.1.1.5
The storage type for this conceptual row. Conceptual rows having the value 'permanent(4)' need not allow write-access to any columnar objects in the row.
Status: current Access: read-only
OBJECT-TYPE    
  StorageType  

mplsLdpGenericGroups 78.5.1.9.1
OBJECT IDENTIFIER    

mplsLdpGenericCompliances 78.5.1.9.2
OBJECT IDENTIFIER    

mplsLdpGenericModuleReadOnlyCompliance 78.5.1.9.2.2
The Module is implemented with support for read-only. In other words, only monitoring is available by implementing this MODULE-COMPLIANCE.
Status: current Access: read-only
MODULE-COMPLIANCE    

mplsLdpGenericGroup 78.5.1.9.1.1
Objects that apply to all MPLS LDP implementations using Generic Labels as the Layer 2.
Status: current Access: read-only
OBJECT-GROUP