OMNI-gx2litePS-MIB

File: OMNI-gx2litePS-MIB.mib (29123 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
RFC-1215 NLS-BBNIDENT-MIB GX2HFC-MIB
NLSBBN-TRAPS-MIB

Imported symbols

IpAddress TimeTicks Counter
OBJECT-TYPE sysUpTime DisplayString
TRAP-TYPE gi motproxies
gx2Liteps trapIdentifier trapNetworkElemModelNumber
trapNetworkElemSerialNum trapPerceivedSeverity trapNetworkElemOperState
trapNetworkElemAlarmStatus trapNetworkElemAdminState trapNetworkElemAvailStatus
trapText trapNETrapLastTrapTimeStamp trapChangedObjectId
trapChangedValueInteger trapChangedValueDisplayString

Defined Types

Float  
Counter    

Gx2LitepsAnalogEntry  
SEQUENCE    
  gx2LitepsAnalogTableIndex INTEGER
  litepslabel12Volt DisplayString Size(0..80)
  litepsuom12Volt DisplayString Size(0..80)
  litepsmajorHigh12Volt Float
  litepsmajorLow12Volt Float
  litepsminorHigh12Volt Float
  litepsminorLow12Volt Float
  litepscurrentValue12Volt Float
  litepsstateFlag12Volt INTEGER
  litepsminValue12Volt Float
  litepsmaxValue12Volt Float
  litepsalarmState12Volt INTEGER
  litepslabel5Volt DisplayString Size(0..80)
  litepsuom5Volt DisplayString Size(0..80)
  litepsmajorHigh5Volt Float
  litepsmajorLow5Volt Float
  litepsminorHigh5Volt Float
  litepsminorLow5Volt Float
  litepscurrentValue5Volt Float
  litepsstateFlag5Volt INTEGER
  litepsminValue5Volt Float
  litepsmaxValue5Volt Float
  litepsalarmState5Volt INTEGER
  litepslabel3Volt DisplayString Size(0..80)
  litepsuom3Volt DisplayString Size(0..80)
  litepsmajorHigh3Volt Float
  litepsmajorLow3Volt Float
  litepsminorHigh3Volt Float
  litepsminorLow3Volt Float
  litepscurrentValue3Volt Float
  litepsstateFlag3Volt INTEGER
  litepsminValue3Volt Float
  litepsmaxValue3Volt Float
  litepsalarmState3Volt INTEGER

Gx2LitepsStatusEntry  
SEQUENCE    
  gx2LitepsStatusTableIndex INTEGER
  litepslabelFan1Status DisplayString Size(0..80)
  litepsvalueFan1Status INTEGER
  litepsstateflagFan1Status INTEGER
  litepslabelFan2Status DisplayString Size(0..80)
  litepsvalueFan2Status INTEGER
  litepsstateflagFan2Status INTEGER

Defined Values

gx2LitepsDescriptor 1.3.6.1.4.1.1166.6.1.2.23.1
OBJECT IDENTIFIER    

gx2LitepsAnalogTable 1.3.6.1.4.1.1166.6.1.2.23.2
This table contains gx2Liteps specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2LitepsAnalogEntry

gx2LitepsAnalogEntry 1.3.6.1.4.1.1166.6.1.2.23.2.1
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2LitepsAnalogEntry  

gx2LitepsStatusTable 1.3.6.1.4.1.1166.6.1.2.23.3
This table contains gx2Liteps specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2LitepsStatusEntry

gx2LitepsStatusEntry 1.3.6.1.4.1.1166.6.1.2.23.3.2
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2LitepsStatusEntry  

gx2LitepsAnalogTableIndex 1.3.6.1.4.1.1166.6.1.2.23.2.1.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

litepslabel12Volt 1.3.6.1.4.1.1166.6.1.2.23.2.1.2
The value of this object provides the label of the 12 Volt Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

litepsuom12Volt 1.3.6.1.4.1.1166.6.1.2.23.2.1.3
The value of this object provides the unit of measure of the 12 Volt Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

litepsmajorHigh12Volt 1.3.6.1.4.1.1166.6.1.2.23.2.1.4
The value of this object provides the Major High alarm value of the 12 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

litepsmajorLow12Volt 1.3.6.1.4.1.1166.6.1.2.23.2.1.5
The value of this object provides the Major Low alarm value of the 12 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

litepsminorHigh12Volt 1.3.6.1.4.1.1166.6.1.2.23.2.1.6
The value of this object provides the Minor High alarm value of the 12 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

litepsminorLow12Volt 1.3.6.1.4.1.1166.6.1.2.23.2.1.7
The value of this object provides the Minor Low alarm value of the 12 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

litepscurrentValue12Volt 1.3.6.1.4.1.1166.6.1.2.23.2.1.8
The value of this object provides the Current value of the 12 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

litepsstateFlag12Volt 1.3.6.1.4.1.1166.6.1.2.23.2.1.9
The value of this object provides the state of the 12 Volt Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

litepsminValue12Volt 1.3.6.1.4.1.1166.6.1.2.23.2.1.10
The value of this object provides the minimum value the 12 Volt Analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 Bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

litepsmaxValue12Volt 1.3.6.1.4.1.1166.6.1.2.23.2.1.11
The value of this object provides the maximum value the 12 Volt Analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 Bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

litepsalarmState12Volt 1.3.6.1.4.1.1166.6.1.2.23.2.1.12
The value of this object provides the curent alarm state of the 12 Volt Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

litepslabel5Volt 1.3.6.1.4.1.1166.6.1.2.23.2.1.13
The value of this object provides the label of the Attenuator Setting Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

litepsuom5Volt 1.3.6.1.4.1.1166.6.1.2.23.2.1.14
The value of this object provides the Unit of Measure of the 5 Volt Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

litepsmajorHigh5Volt 1.3.6.1.4.1.1166.6.1.2.23.2.1.15
The value of this object provides the Major High alarm value of the 5 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

litepsmajorLow5Volt 1.3.6.1.4.1.1166.6.1.2.23.2.1.16
The value of this object provides the Major Low alarm value of the 5 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

litepsminorHigh5Volt 1.3.6.1.4.1.1166.6.1.2.23.2.1.17
The value of this object provides the Minor High alarm value of the 5 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

litepsminorLow5Volt 1.3.6.1.4.1.1166.6.1.2.23.2.1.18
The value of this object provides the Minor Low alarm value of the 5 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

litepscurrentValue5Volt 1.3.6.1.4.1.1166.6.1.2.23.2.1.19
The value of this object provides the Current value of the 5 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

litepsstateFlag5Volt 1.3.6.1.4.1.1166.6.1.2.23.2.1.20
The value of this object provides the state of the 5 Volt Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

litepsminValue5Volt 1.3.6.1.4.1.1166.6.1.2.23.2.1.21
The value of this object provides the minimum value the 5 Volt Analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 Bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

litepsmaxValue5Volt 1.3.6.1.4.1.1166.6.1.2.23.2.1.22
The value of this object provides the maximum value the 5 Volt Analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 Bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

litepsalarmState5Volt 1.3.6.1.4.1.1166.6.1.2.23.2.1.23
The value of this object provides the curent alarm state of the 5 Volt Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

litepslabel3Volt 1.3.6.1.4.1.1166.6.1.2.23.2.1.24
The value of this object provides the label of the 3 Anode Volt Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

litepsuom3Volt 1.3.6.1.4.1.1166.6.1.2.23.2.1.25
The value of this object provides the Unit of Measure of the 3.7V anode voltage analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

litepsmajorHigh3Volt 1.3.6.1.4.1.1166.6.1.2.23.2.1.26
The value of this object provides the Major High alarm value of the 3.7V anode voltage analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

litepsmajorLow3Volt 1.3.6.1.4.1.1166.6.1.2.23.2.1.27
The value of this object provides the Major Low alarm value of the 3.7V anode voltage analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

litepsminorHigh3Volt 1.3.6.1.4.1.1166.6.1.2.23.2.1.28
The value of this object provides the Minor High alarm value of the 3.7V anode voltage analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

litepsminorLow3Volt 1.3.6.1.4.1.1166.6.1.2.23.2.1.29
The value of this object provides the Minor Low alarm value of the 3.7V anode voltage analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

litepscurrentValue3Volt 1.3.6.1.4.1.1166.6.1.2.23.2.1.30
The value of this object provides the Current value of the 3.7V anode voltage analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

litepsstateFlag3Volt 1.3.6.1.4.1.1166.6.1.2.23.2.1.31
The value of this object provides the state of the 3 Volt Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

litepsminValue3Volt 1.3.6.1.4.1.1166.6.1.2.23.2.1.32
The value of this object provides the minimum value that the 3.7V anode voltage analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 Bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

litepsmaxValue3Volt 1.3.6.1.4.1.1166.6.1.2.23.2.1.33
The value of this object provides the maximum value that the 3.7V anode voltage analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 Bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

litepsalarmState3Volt 1.3.6.1.4.1.1166.6.1.2.23.2.1.34
The value of this object provides the curent alarm state of the 3.7V anode voltage analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

gx2LitepsStatusTableIndex 1.3.6.1.4.1.1166.6.1.2.23.3.2.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

litepslabelFan1Status 1.3.6.1.4.1.1166.6.1.2.23.3.2.2
The value of this object provides the label of the Fan 1 Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

litepsvalueFan1Status 1.3.6.1.4.1.1166.6.1.2.23.3.2.3
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

litepsstateflagFan1Status 1.3.6.1.4.1.1166.6.1.2.23.3.2.4
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

litepslabelFan2Status 1.3.6.1.4.1.1166.6.1.2.23.3.2.5
The value of this object provides the label of the Fan 2 Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

litepsvalueFan2Status 1.3.6.1.4.1.1166.6.1.2.23.3.2.6
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

litepsstateflagFan2Status 1.3.6.1.4.1.1166.6.1.2.23.3.2.7
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

trapLitepsConfigChangeInteger 1
This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapLitepsConfigChangeDisplayString 2
This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapLitepsFanCurrent1 3
This trap is issued when Fan 1 is in an alarm condition.
TRAP-TYPE    

trapLitepsFanCurrent2 4
This trap is issued when Fan 2 is in an alarm condition.
TRAP-TYPE    

trapLiteps12Volt 5
This trap is issued when the 12 Volts is in an alarm condition.
TRAP-TYPE    

trapLiteps5Volt 6
This trap is issued when the 5.1 Volts is in an alarm condition.
TRAP-TYPE    

trapLiteps3Volt 7
This trap is issued when the 3.7 Volts is in an alarm condition.
TRAP-TYPE