OMNI-gx2litePS-MIB
File:
OMNI-gx2litePS-MIB.mib (29123 bytes)
Imported modules
Imported symbols
Defined Types
Gx2LitepsAnalogEntry |
|
SEQUENCE |
|
|
|
|
gx2LitepsAnalogTableIndex |
INTEGER |
|
|
litepslabel12Volt |
DisplayString |
Size(0..80) |
|
litepsuom12Volt |
DisplayString |
Size(0..80) |
|
litepsmajorHigh12Volt |
Float |
|
|
litepsmajorLow12Volt |
Float |
|
|
litepsminorHigh12Volt |
Float |
|
|
litepsminorLow12Volt |
Float |
|
|
litepscurrentValue12Volt |
Float |
|
|
litepsstateFlag12Volt |
INTEGER |
|
|
litepsminValue12Volt |
Float |
|
|
litepsmaxValue12Volt |
Float |
|
|
litepsalarmState12Volt |
INTEGER |
|
|
litepslabel5Volt |
DisplayString |
Size(0..80) |
|
litepsuom5Volt |
DisplayString |
Size(0..80) |
|
litepsmajorHigh5Volt |
Float |
|
|
litepsmajorLow5Volt |
Float |
|
|
litepsminorHigh5Volt |
Float |
|
|
litepsminorLow5Volt |
Float |
|
|
litepscurrentValue5Volt |
Float |
|
|
litepsstateFlag5Volt |
INTEGER |
|
|
litepsminValue5Volt |
Float |
|
|
litepsmaxValue5Volt |
Float |
|
|
litepsalarmState5Volt |
INTEGER |
|
|
litepslabel3Volt |
DisplayString |
Size(0..80) |
|
litepsuom3Volt |
DisplayString |
Size(0..80) |
|
litepsmajorHigh3Volt |
Float |
|
|
litepsmajorLow3Volt |
Float |
|
|
litepsminorHigh3Volt |
Float |
|
|
litepsminorLow3Volt |
Float |
|
|
litepscurrentValue3Volt |
Float |
|
|
litepsstateFlag3Volt |
INTEGER |
|
|
litepsminValue3Volt |
Float |
|
|
litepsmaxValue3Volt |
Float |
|
|
litepsalarmState3Volt |
INTEGER |
|
Gx2LitepsStatusEntry |
|
SEQUENCE |
|
|
|
|
gx2LitepsStatusTableIndex |
INTEGER |
|
|
litepslabelFan1Status |
DisplayString |
Size(0..80) |
|
litepsvalueFan1Status |
INTEGER |
|
|
litepsstateflagFan1Status |
INTEGER |
|
|
litepslabelFan2Status |
DisplayString |
Size(0..80) |
|
litepsvalueFan2Status |
INTEGER |
|
|
litepsstateflagFan2Status |
INTEGER |
|
Defined Values
gx2LitepsAnalogTable |
1.3.6.1.4.1.1166.6.1.2.23.2 |
This table contains gx2Liteps specific parameters with
nominal and current values. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Gx2LitepsAnalogEntry |
|
gx2LitepsAnalogEntry |
1.3.6.1.4.1.1166.6.1.2.23.2.1 |
This list contains digital product class and the
associated RF channel parameters and descriptions. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Gx2LitepsAnalogEntry |
|
|
gx2LitepsStatusTable |
1.3.6.1.4.1.1166.6.1.2.23.3 |
This table contains gx2Liteps specific parameters with
nominal and current values. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Gx2LitepsStatusEntry |
|
gx2LitepsStatusEntry |
1.3.6.1.4.1.1166.6.1.2.23.3.2 |
This list contains digital product class and the
associated RF channel parameters and descriptions. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Gx2LitepsStatusEntry |
|
|
gx2LitepsAnalogTableIndex |
1.3.6.1.4.1.1166.6.1.2.23.2.1.1 |
The value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..4294967295 |
|
litepslabel12Volt |
1.3.6.1.4.1.1166.6.1.2.23.2.1.2 |
The value of this object provides the label of the 12 Volt Analog parameter. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
litepsuom12Volt |
1.3.6.1.4.1.1166.6.1.2.23.2.1.3 |
The value of this object provides the unit of measure of the 12 Volt
Analog parameter. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
litepsmajorHigh12Volt |
1.3.6.1.4.1.1166.6.1.2.23.2.1.4 |
The value of this object provides the Major High alarm value of the 12 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
litepsmajorLow12Volt |
1.3.6.1.4.1.1166.6.1.2.23.2.1.5 |
The value of this object provides the Major Low alarm value of the 12 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
litepsminorHigh12Volt |
1.3.6.1.4.1.1166.6.1.2.23.2.1.6 |
The value of this object provides the Minor High alarm value of the 12 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
litepsminorLow12Volt |
1.3.6.1.4.1.1166.6.1.2.23.2.1.7 |
The value of this object provides the Minor Low alarm value of the 12 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
litepscurrentValue12Volt |
1.3.6.1.4.1.1166.6.1.2.23.2.1.8 |
The value of this object provides the Current value of the 12 Volt Analog
parameter. This value is a floating point number that is represented as an
IEEE 32 Bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
litepsstateFlag12Volt |
1.3.6.1.4.1.1166.6.1.2.23.2.1.9 |
The value of this object provides the state of the 12 Volt Analog parameter.
(0-Hidden 1-Read-Only, 2-Updateable) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
hidden(1), read-only(2), updateable(3) |
|
litepsminValue12Volt |
1.3.6.1.4.1.1166.6.1.2.23.2.1.10 |
The value of this object provides the minimum value the 12 Volt Analog
parameter can achieve. This value is a floating point number that is
represented as an IEEE 32 Bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
litepsmaxValue12Volt |
1.3.6.1.4.1.1166.6.1.2.23.2.1.11 |
The value of this object provides the maximum value the 12 Volt Analog
parameter can achieve. This value is a floating point number that is
represented as an IEEE 32 Bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
litepsalarmState12Volt |
1.3.6.1.4.1.1166.6.1.2.23.2.1.12 |
The value of this object provides the curent alarm state of the 12 Volt Analog
parameter. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) |
|
litepslabel5Volt |
1.3.6.1.4.1.1166.6.1.2.23.2.1.13 |
The value of this object provides the label of the Attenuator Setting Analog
parameter. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
litepsuom5Volt |
1.3.6.1.4.1.1166.6.1.2.23.2.1.14 |
The value of this object provides the Unit of Measure of the 5 Volt Analog
parameter. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
litepsmajorHigh5Volt |
1.3.6.1.4.1.1166.6.1.2.23.2.1.15 |
The value of this object provides the Major High alarm value of the 5 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
litepsmajorLow5Volt |
1.3.6.1.4.1.1166.6.1.2.23.2.1.16 |
The value of this object provides the Major Low alarm value of the 5 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
litepsminorHigh5Volt |
1.3.6.1.4.1.1166.6.1.2.23.2.1.17 |
The value of this object provides the Minor High alarm value of the 5 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
litepsminorLow5Volt |
1.3.6.1.4.1.1166.6.1.2.23.2.1.18 |
The value of this object provides the Minor Low alarm value of the 5 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
litepscurrentValue5Volt |
1.3.6.1.4.1.1166.6.1.2.23.2.1.19 |
The value of this object provides the Current value of the 5 Volt Analog
parameter. This value is a floating point number that is represented as
an IEEE 32 Bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
litepsstateFlag5Volt |
1.3.6.1.4.1.1166.6.1.2.23.2.1.20 |
The value of this object provides the state of the 5 Volt Analog parameter.
(0-Hidden 1-Read-Only, 2-Updateable). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
hidden(1), read-only(2), updateable(3) |
|
litepsminValue5Volt |
1.3.6.1.4.1.1166.6.1.2.23.2.1.21 |
The value of this object provides the minimum value the 5 Volt Analog
parameter can achieve. This value is a floating point number that is
represented as an IEEE 32 Bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
litepsmaxValue5Volt |
1.3.6.1.4.1.1166.6.1.2.23.2.1.22 |
The value of this object provides the maximum value the 5 Volt Analog parameter
can achieve. This value is a floating point number that is represented as an
IEEE 32 Bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
litepsalarmState5Volt |
1.3.6.1.4.1.1166.6.1.2.23.2.1.23 |
The value of this object provides the curent alarm state of the 5 Volt
Analog parameter. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) |
|
litepslabel3Volt |
1.3.6.1.4.1.1166.6.1.2.23.2.1.24 |
The value of this object provides the label of the
3 Anode Volt Analog parameter. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
litepsuom3Volt |
1.3.6.1.4.1.1166.6.1.2.23.2.1.25 |
The value of this object provides the Unit of Measure of the 3.7V anode voltage
analog parameter. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
litepsmajorHigh3Volt |
1.3.6.1.4.1.1166.6.1.2.23.2.1.26 |
The value of this object provides the Major High alarm value of the 3.7V anode
voltage analog parameter. This value is a floating point number that is
represented as an IEEE 32 Bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
litepsmajorLow3Volt |
1.3.6.1.4.1.1166.6.1.2.23.2.1.27 |
The value of this object provides the Major Low alarm value of the 3.7V anode
voltage analog parameter. This value is a floating point number that is
represented as an IEEE 32 Bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
litepsminorHigh3Volt |
1.3.6.1.4.1.1166.6.1.2.23.2.1.28 |
The value of this object provides the Minor High alarm value of the 3.7V anode
voltage analog parameter. This value is a floating point number that is
represented as an IEEE 32 Bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
litepsminorLow3Volt |
1.3.6.1.4.1.1166.6.1.2.23.2.1.29 |
The value of this object provides the Minor Low alarm value of the 3.7V anode
voltage analog parameter. This value is a floating point number that is
represented as an IEEE 32 Bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
litepscurrentValue3Volt |
1.3.6.1.4.1.1166.6.1.2.23.2.1.30 |
The value of this object provides the Current value of the 3.7V anode voltage
analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
litepsstateFlag3Volt |
1.3.6.1.4.1.1166.6.1.2.23.2.1.31 |
The value of this object provides the state of the 3 Volt Analog parameter.
(0-Hidden 1-Read-Only, 2-Updateable). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
hidden(1), read-only(2), updateable(3) |
|
litepsminValue3Volt |
1.3.6.1.4.1.1166.6.1.2.23.2.1.32 |
The value of this object provides the minimum value that the 3.7V anode voltage
analog parameter can achieve. This value is a floating point number that is
represented as an IEEE 32 Bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
litepsmaxValue3Volt |
1.3.6.1.4.1.1166.6.1.2.23.2.1.33 |
The value of this object provides the maximum value that the 3.7V anode voltage
analog parameter can achieve. This value is a floating point number that is
represented as an IEEE 32 Bit number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Float |
|
|
litepsalarmState3Volt |
1.3.6.1.4.1.1166.6.1.2.23.2.1.34 |
The value of this object provides the curent alarm state of the 3.7V anode
voltage analog parameter. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) |
|
gx2LitepsStatusTableIndex |
1.3.6.1.4.1.1166.6.1.2.23.3.2.1 |
The value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..4294967295 |
|
litepslabelFan1Status |
1.3.6.1.4.1.1166.6.1.2.23.3.2.2 |
The value of this object provides the label of the
Fan 1 Status parameter. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
litepsvalueFan1Status |
1.3.6.1.4.1.1166.6.1.2.23.3.2.3 |
The value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) |
|
litepsstateflagFan1Status |
1.3.6.1.4.1.1166.6.1.2.23.3.2.4 |
The value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
hidden(1), read-only(2), updateable(3) |
|
litepslabelFan2Status |
1.3.6.1.4.1.1166.6.1.2.23.3.2.5 |
The value of this object provides the label of the
Fan 2 Status parameter. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
litepsvalueFan2Status |
1.3.6.1.4.1.1166.6.1.2.23.3.2.6 |
The value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) |
|
litepsstateflagFan2Status |
1.3.6.1.4.1.1166.6.1.2.23.3.2.7 |
The value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
hidden(1), read-only(2), updateable(3) |
|
trapLitepsConfigChangeInteger |
1 |
This trap is issued if configuration of a single variable
with integer type was changed (via ANY interface).
TrapChangedValueInteger variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' |
TRAP-TYPE |
|
|
|
trapLitepsConfigChangeDisplayString |
2 |
This trap is issued if configuration of a single variable
with DispalayString type was changed (via ANY interface).
TrapChangedValueDisplayString variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' |
TRAP-TYPE |
|
|
|
trapLiteps12Volt |
5 |
This trap is issued when the 12 Volts is in an alarm condition. |
TRAP-TYPE |
|
|
|
trapLiteps5Volt |
6 |
This trap is issued when the 5.1 Volts is in an alarm condition. |
TRAP-TYPE |
|
|
|
trapLiteps3Volt |
7 |
This trap is issued when the 3.7 Volts is in an alarm condition. |
TRAP-TYPE |
|
|
|