OMNI-gx2CEB-MIB

File: OMNI-gx2CEB-MIB.mib (60185 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
RFC-1215 NLS-BBNIDENT-MIB GX2HFC-MIB
NLSBBN-TRAPS-MIB

Imported symbols

IpAddress TimeTicks Counter
OBJECT-TYPE sysUpTime DisplayString
TRAP-TYPE gi motproxies
gx2CEB trapIdentifier trapNetworkElemModelNumber
trapNetworkElemSerialNum trapPerceivedSeverity trapNetworkElemOperState
trapNetworkElemAlarmStatus trapNetworkElemAdminState trapNetworkElemAvailStatus
trapText trapNETrapLastTrapTimeStamp trapChangedObjectId
trapChangedValueInteger trapChangedValueDisplayString

Defined Types

Float  
Counter    

Gx2CEBAnalogEntry  
SEQUENCE    
  gx2CEBAnalogTableIndex INTEGER
  ceblabelModTemp DisplayString Size(0..80)
  cebuomModTemp DisplayString Size(0..80)
  cebmajorHighModTemp Float
  cebmajorLowModTemp Float
  cebminorHighModTemp Float
  cebminorLowModTemp Float
  cebcurrentValueModTemp Float
  cebstateFlagModTemp INTEGER
  cebminValueModTemp Float
  cebmaxValueModTemp Float
  cebalarmStateModTemp INTEGER
  ceblabelFanCurrent DisplayString Size(0..80)
  cebuomFanCurrent DisplayString Size(0..80)
  cebmajorHighFanCurrent Float
  cebmajorLowFanCurrent Float
  cebminorHighFanCurrent Float
  cebminorLowFanCurrent Float
  cebcurrentValueFanCurrent Float
  cebstateFlagFanCurrent INTEGER
  cebminValueFanCurrent Float
  cebmaxValueFanCurrent Float
  cebalarmStateFanCurrent INTEGER
  ceblabelAnalogVoltage01 DisplayString Size(0..80)
  cebuomAnalogVoltage01 DisplayString Size(0..80)
  cebmajorHighAnalogVoltage01 Float
  cebmajorLowAnalogVoltage01 Float
  cebminorHighAnalogVoltage01 Float
  cebminorLowAnalogVoltage01 Float
  cebcurrentValueAnalogVoltage01 Float
  cebstateFlagAnalogVoltage01 INTEGER
  cebminValueAnalogVoltage01 Float
  cebmaxValueAnalogVoltage01 Float
  cebalarmStateAnalogVoltage01 INTEGER
  ceblabelAnalogVoltage02 DisplayString Size(0..80)
  cebuomAnalogVoltage02 DisplayString Size(0..80)
  cebmajorHighAnalogVoltage02 Float
  cebmajorLowAnalogVoltage02 Float
  cebminorHighAnalogVoltage02 Float
  cebminorLowAnalogVoltage02 Float
  cebcurrentValueAnalogVoltage02 Float
  cebstateFlagAnalogVoltage02 INTEGER
  cebminValueAnalogVoltage02 Float
  cebmaxValueAnalogVoltage02 Float
  cebalarmStateAnalogVoltage02 INTEGER
  ceblabelAnalogVoltage03 DisplayString Size(0..80)
  cebuomAnalogVoltage03 DisplayString Size(0..80)
  cebmajorHighAnalogVoltage03 Float
  cebmajorLowAnalogVoltage03 Float
  cebminorHighAnalogVoltage03 Float
  cebminorLowAnalogVoltage03 Float
  cebcurrentValueAnalogVoltage03 Float
  cebstateFlagAnalogVoltage03 INTEGER
  cebminValueAnalogVoltage03 Float
  cebmaxValueAnalogVoltage03 Float
  cebalarmStateAnalogVoltage03 INTEGER
  ceblabelAnalogVoltage04 DisplayString Size(0..80)
  cebuomAnalogVoltage04 DisplayString Size(0..80)
  cebmajorHighAnalogVoltage04 Float
  cebmajorLowAnalogVoltage04 Float
  cebminorHighAnalogVoltage04 Float
  cebminorLowAnalogVoltage04 Float
  cebcurrentValueAnalogVoltage04 Float
  cebstateFlagAnalogVoltage04 INTEGER
  cebminValueAnalogVoltage04 Float
  cebmaxValueAnalogVoltage04 Float
  cebalarmStateAnalogVoltage04 INTEGER
  ceblabelAnalogVoltage05 DisplayString Size(0..80)
  cebuomAnalogVoltage05 DisplayString Size(0..80)
  cebmajorHighAnalogVoltage05 Float
  cebmajorLowAnalogVoltage05 Float
  cebminorHighAnalogVoltage05 Float
  cebminorLowAnalogVoltage05 Float
  cebcurrentValueAnalogVoltage05 Float
  cebstateFlagAnalogVoltage05 INTEGER
  cebminValueAnalogVoltage05 Float
  cebmaxValueAnalogVoltage05 Float
  cebalarmStateAnalogVoltage05 INTEGER

Gx2CEBStatusEntry  
SEQUENCE    
  gx2CEBStatusTableIndex INTEGER
  ceblabelBoot DisplayString Size(0..80)
  cebvalueBoot INTEGER
  cebstateflagBoot INTEGER
  ceblabelFlash DisplayString Size(0..80)
  cebvalueFlash INTEGER
  cebstateflagFlash INTEGER
  ceblabelFactoryDataCRC DisplayString Size(0..80)
  cebvalueFactoryDataCRC INTEGER
  cebstateflagFactoryDataCRC INTEGER
  ceblabelAlarmDataCrc DisplayString Size(0..80)
  cebvalueAlarmDataCrc INTEGER
  cebstateflagAlarmDataCrc INTEGER

Gx2CEBFactoryEntry  
SEQUENCE    
  gx2CEBFactoryTableIndex INTEGER
  cebbootControlByte INTEGER
  cebbootStatusByte INTEGER
  cebbank1CRC INTEGER
  cebbank2CRC INTEGER
  cebprgEEPROMByte INTEGER
  cebfactoryCRC INTEGER
  cebcalculateCRC INTEGER
  cebhourMeter INTEGER
  cebflashPrgCntA INTEGER
  cebflashPrgCntB INTEGER
  cebflashBankARev DisplayString Size(0..80)
  cebflashBankBRev DisplayString Size(0..80)

Defined Values

gx2CEBDescriptor 1.3.6.1.4.1.1166.6.1.2.20.1
OBJECT IDENTIFIER    

gx2CEBAnalogTable 1.3.6.1.4.1.1166.6.1.2.20.2
This table contains gx2CEB specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2CEBAnalogEntry

gx2CEBAnalogEntry 1.3.6.1.4.1.1166.6.1.2.20.2.1
This list contains the analog parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2CEBAnalogEntry  

gx2CEBStatusTable 1.3.6.1.4.1.1166.6.1.2.20.3
This table contains gx2CEB specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2CEBStatusEntry

gx2CEBStatusEntry 1.3.6.1.4.1.1166.6.1.2.20.3.2
This list contains Status parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2CEBStatusEntry  

gx2CEBFactoryTable 1.3.6.1.4.1.1166.6.1.2.20.4
This table contains gx2CEB specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2CEBFactoryEntry

gx2CEBFactoryEntry 1.3.6.1.4.1.1166.6.1.2.20.4.3
This list contains Factory parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2CEBFactoryEntry  

gx2CEBAnalogTableIndex 1.3.6.1.4.1.1166.6.1.2.20.2.1.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

ceblabelModTemp 1.3.6.1.4.1.1166.6.1.2.20.2.1.2
The value of this object provides the label of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

cebuomModTemp 1.3.6.1.4.1.1166.6.1.2.20.2.1.3
The value of this object provides the Unit of Measure of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

cebmajorHighModTemp 1.3.6.1.4.1.1166.6.1.2.20.2.1.4
The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebmajorLowModTemp 1.3.6.1.4.1.1166.6.1.2.20.2.1.5
The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebminorHighModTemp 1.3.6.1.4.1.1166.6.1.2.20.2.1.6
The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebminorLowModTemp 1.3.6.1.4.1.1166.6.1.2.20.2.1.7
The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebcurrentValueModTemp 1.3.6.1.4.1.1166.6.1.2.20.2.1.8
The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebstateFlagModTemp 1.3.6.1.4.1.1166.6.1.2.20.2.1.9
The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

cebminValueModTemp 1.3.6.1.4.1.1166.6.1.2.20.2.1.10
The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebmaxValueModTemp 1.3.6.1.4.1.1166.6.1.2.20.2.1.11
The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebalarmStateModTemp 1.3.6.1.4.1.1166.6.1.2.20.2.1.12
The value of this object provides the curent alarm state of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

ceblabelFanCurrent 1.3.6.1.4.1.1166.6.1.2.20.2.1.13
The value of this object provides the label of the Fan Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

cebuomFanCurrent 1.3.6.1.4.1.1166.6.1.2.20.2.1.14
The value of this object provides the Unit of Measure of the Fan Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

cebmajorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.20.2.1.15
The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebmajorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.20.2.1.16
The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebminorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.20.2.1.17
The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

cebminorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.20.2.1.18
The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

cebcurrentValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.20.2.1.19
The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebstateFlagFanCurrent 1.3.6.1.4.1.1166.6.1.2.20.2.1.20
The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

cebminValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.20.2.1.21
The value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebmaxValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.20.2.1.22
The value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebalarmStateFanCurrent 1.3.6.1.4.1.1166.6.1.2.20.2.1.23
The value of this object provides the curent alarm state of the Fan Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

ceblabelAnalogVoltage01 1.3.6.1.4.1.1166.6.1.2.20.2.1.24
The value of this object provides the label of the Analog Voltage number 01 Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

cebuomAnalogVoltage01 1.3.6.1.4.1.1166.6.1.2.20.2.1.25
The value of this object provides the Unit of Measure of the Analog Voltage number 01 Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

cebmajorHighAnalogVoltage01 1.3.6.1.4.1.1166.6.1.2.20.2.1.26
The value of this object provides the Major High alarm value Analog Voltage number 01 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebmajorLowAnalogVoltage01 1.3.6.1.4.1.1166.6.1.2.20.2.1.27
The value of this object provides the Major Low alarm value Analog Voltage number 01 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebminorHighAnalogVoltage01 1.3.6.1.4.1.1166.6.1.2.20.2.1.28
The value of this object provides the Minor High alarm value Analog Voltage number 01 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebminorLowAnalogVoltage01 1.3.6.1.4.1.1166.6.1.2.20.2.1.29
The value of this object provides the Minor Low alarm value Analog Voltage number 01 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebcurrentValueAnalogVoltage01 1.3.6.1.4.1.1166.6.1.2.20.2.1.30
The value of this object provides the Current value Analog Voltage number 01 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebstateFlagAnalogVoltage01 1.3.6.1.4.1.1166.6.1.2.20.2.1.31
The value of this object provides the state of the Analog Voltage number 01 Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

cebminValueAnalogVoltage01 1.3.6.1.4.1.1166.6.1.2.20.2.1.32
The value of this object provides the minimum value the Analog Voltage number 01 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebmaxValueAnalogVoltage01 1.3.6.1.4.1.1166.6.1.2.20.2.1.33
The value of this object provides the maximum value the Analog Voltage number 01 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebalarmStateAnalogVoltage01 1.3.6.1.4.1.1166.6.1.2.20.2.1.34
The value of this object provides the curent alarm state of the Analog Voltage number 01 Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

ceblabelAnalogVoltage02 1.3.6.1.4.1.1166.6.1.2.20.2.1.35
The value of this object provides the label of the Analog Voltage number 02 Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

cebuomAnalogVoltage02 1.3.6.1.4.1.1166.6.1.2.20.2.1.36
The value of this object provides the Unit of Measure of the Analog Voltage number 02 Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

cebmajorHighAnalogVoltage02 1.3.6.1.4.1.1166.6.1.2.20.2.1.37
The value of this object provides the Major High alarm value Analog Voltage number 02 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebmajorLowAnalogVoltage02 1.3.6.1.4.1.1166.6.1.2.20.2.1.38
The value of this object provides the Major Low alarm value Analog Voltage number 02 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebminorHighAnalogVoltage02 1.3.6.1.4.1.1166.6.1.2.20.2.1.39
The value of this object provides the Minor High alarm value Analog Voltage number 02 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebminorLowAnalogVoltage02 1.3.6.1.4.1.1166.6.1.2.20.2.1.40
The value of this object provides the Minor Low alarm value Analog Voltage number 02 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebcurrentValueAnalogVoltage02 1.3.6.1.4.1.1166.6.1.2.20.2.1.41
The value of this object provides the Current value Analog Voltage number 02 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebstateFlagAnalogVoltage02 1.3.6.1.4.1.1166.6.1.2.20.2.1.42
The value of this object provides the state of the Analog Voltage number 02 Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

cebminValueAnalogVoltage02 1.3.6.1.4.1.1166.6.1.2.20.2.1.43
The value of this object provides the minimum value the Analog Voltage number 02 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebmaxValueAnalogVoltage02 1.3.6.1.4.1.1166.6.1.2.20.2.1.44
The value of this object provides the maximum value the Analog Voltage number 02 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebalarmStateAnalogVoltage02 1.3.6.1.4.1.1166.6.1.2.20.2.1.45
The value of this object provides the curent alarm state of the Analog Voltage number 02 Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

ceblabelAnalogVoltage03 1.3.6.1.4.1.1166.6.1.2.20.2.1.46
The value of this object provides the label of the Analog Voltage number 03 Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

cebuomAnalogVoltage03 1.3.6.1.4.1.1166.6.1.2.20.2.1.47
The value of this object provides the Unit of Measure of the Analog Voltage number 03 Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

cebmajorHighAnalogVoltage03 1.3.6.1.4.1.1166.6.1.2.20.2.1.48
The value of this object provides the Major High alarm value Analog Voltage number 03 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebmajorLowAnalogVoltage03 1.3.6.1.4.1.1166.6.1.2.20.2.1.49
The value of this object provides the Major Low alarm value Analog Voltage number 03 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebminorHighAnalogVoltage03 1.3.6.1.4.1.1166.6.1.2.20.2.1.50
The value of this object provides the Minor High alarm value Analog Voltage number 03 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebminorLowAnalogVoltage03 1.3.6.1.4.1.1166.6.1.2.20.2.1.51
The value of this object provides the Minor Low alarm value Analog Voltage number 03 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebcurrentValueAnalogVoltage03 1.3.6.1.4.1.1166.6.1.2.20.2.1.52
The value of this object provides the Current value Analog Voltage number 03 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebstateFlagAnalogVoltage03 1.3.6.1.4.1.1166.6.1.2.20.2.1.53
The value of this object provides the state of the Analog Voltage number 03 Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

cebminValueAnalogVoltage03 1.3.6.1.4.1.1166.6.1.2.20.2.1.54
The value of this object provides the minimum value the Analog Voltage number 03 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebmaxValueAnalogVoltage03 1.3.6.1.4.1.1166.6.1.2.20.2.1.55
The value of this object provides the maximum value the Analog Voltage number 03 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebalarmStateAnalogVoltage03 1.3.6.1.4.1.1166.6.1.2.20.2.1.56
The value of this object provides the curent alarm state of the Analog Voltage number 03 Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

ceblabelAnalogVoltage04 1.3.6.1.4.1.1166.6.1.2.20.2.1.57
The value of this object provides the label of the Analog Voltage number 04 Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

cebuomAnalogVoltage04 1.3.6.1.4.1.1166.6.1.2.20.2.1.58
The value of this object provides the Unit of Measure of the Analog Voltage number 04 Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

cebmajorHighAnalogVoltage04 1.3.6.1.4.1.1166.6.1.2.20.2.1.59
The value of this object provides the Major High alarm value Analog Voltage number 04 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebmajorLowAnalogVoltage04 1.3.6.1.4.1.1166.6.1.2.20.2.1.60
The value of this object provides the Major Low alarm value Analog Voltage number 04 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebminorHighAnalogVoltage04 1.3.6.1.4.1.1166.6.1.2.20.2.1.61
The value of this object provides the Minor High alarm value Analog Voltage number 04 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebminorLowAnalogVoltage04 1.3.6.1.4.1.1166.6.1.2.20.2.1.62
The value of this object provides the Minor Low alarm value Analog Voltage number 04 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebcurrentValueAnalogVoltage04 1.3.6.1.4.1.1166.6.1.2.20.2.1.63
The value of this object provides the Current value Analog Voltage number 04 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebstateFlagAnalogVoltage04 1.3.6.1.4.1.1166.6.1.2.20.2.1.64
The value of this object provides the state of the Analog Voltage number 04 Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

cebminValueAnalogVoltage04 1.3.6.1.4.1.1166.6.1.2.20.2.1.65
The value of this object provides the minimum value the Analog Voltage number 04 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebmaxValueAnalogVoltage04 1.3.6.1.4.1.1166.6.1.2.20.2.1.66
The value of this object provides the maximum value the Analog Voltage number 04 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebalarmStateAnalogVoltage04 1.3.6.1.4.1.1166.6.1.2.20.2.1.67
The value of this object provides the curent alarm state of the Analog Voltage number 04 Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

ceblabelAnalogVoltage05 1.3.6.1.4.1.1166.6.1.2.20.2.1.68
The value of this object provides the label of the Analog Voltage number 05 Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

cebuomAnalogVoltage05 1.3.6.1.4.1.1166.6.1.2.20.2.1.69
The value of this object provides the Unit of Measure of the Analog Voltage number 05 Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

cebmajorHighAnalogVoltage05 1.3.6.1.4.1.1166.6.1.2.20.2.1.70
The value of this object provides the Major High alarm value Analog Voltage number 05 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebmajorLowAnalogVoltage05 1.3.6.1.4.1.1166.6.1.2.20.2.1.71
The value of this object provides the Major Low alarm value Analog Voltage number 05 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebminorHighAnalogVoltage05 1.3.6.1.4.1.1166.6.1.2.20.2.1.72
The value of this object provides the Minor High alarm value Analog Voltage number 05 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebminorLowAnalogVoltage05 1.3.6.1.4.1.1166.6.1.2.20.2.1.73
The value of this object provides the Minor Low alarm value Analog Voltage number 05 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebcurrentValueAnalogVoltage05 1.3.6.1.4.1.1166.6.1.2.20.2.1.74
The value of this object provides the Current value Analog Voltage number 05 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebstateFlagAnalogVoltage05 1.3.6.1.4.1.1166.6.1.2.20.2.1.75
The value of this object provides the state of the Analog Voltage number 05 Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

cebminValueAnalogVoltage05 1.3.6.1.4.1.1166.6.1.2.20.2.1.76
The value of this object provides the minimum value the Analog Voltage number 05 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebmaxValueAnalogVoltage05 1.3.6.1.4.1.1166.6.1.2.20.2.1.77
The value of this object provides the maximum value the Analog Voltage number 05 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

cebalarmStateAnalogVoltage05 1.3.6.1.4.1.1166.6.1.2.20.2.1.78
The value of this object provides the curent alarm state of the Analog Voltage number 01 Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

gx2CEBStatusTableIndex 1.3.6.1.4.1.1166.6.1.2.20.3.2.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

ceblabelBoot 1.3.6.1.4.1.1166.6.1.2.20.3.2.2
The value of this object provides the label of the Boot Status Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

cebvalueBoot 1.3.6.1.4.1.1166.6.1.2.20.3.2.3
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

cebstateflagBoot 1.3.6.1.4.1.1166.6.1.2.20.3.2.4
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

ceblabelFlash 1.3.6.1.4.1.1166.6.1.2.20.3.2.5
The value of this object provides the label of the Flash Status Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

cebvalueFlash 1.3.6.1.4.1.1166.6.1.2.20.3.2.6
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

cebstateflagFlash 1.3.6.1.4.1.1166.6.1.2.20.3.2.7
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

ceblabelFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.20.3.2.8
The value of this object provides the label of the Factory Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

cebvalueFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.20.3.2.9
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

cebstateflagFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.20.3.2.10
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

ceblabelAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.20.3.2.11
The value of this object provides the label of the Alarm Data Crc parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

cebvalueAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.20.3.2.12
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

cebstateflagAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.20.3.2.13
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gx2CEBFactoryTableIndex 1.3.6.1.4.1.1166.6.1.2.20.4.3.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

cebbootControlByte 1.3.6.1.4.1.1166.6.1.2.20.4.3.2
The value of this object indicates which bank the firmware is currently being boot from.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cebbootStatusByte 1.3.6.1.4.1.1166.6.1.2.20.4.3.3
This object indicates the status of the last boot. Bit 2 = Bank 0/1 Active (0 = Bank 0, 1 = Bank 1), Bit 1 = Bank 1 Fail and Bit 0 = Bank 0 Fail (0 = Pass, 1 = Fail)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cebbank1CRC 1.3.6.1.4.1.1166.6.1.2.20.4.3.4
This object provides the CRC code of bank 0. The display formate for the data is Hex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cebbank2CRC 1.3.6.1.4.1.1166.6.1.2.20.4.3.5
This object provides the CRC code of bank 1.The display formate for the data is Hex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cebprgEEPROMByte 1.3.6.1.4.1.1166.6.1.2.20.4.3.6
This object indicates if the EEPROM has been programmed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cebfactoryCRC 1.3.6.1.4.1.1166.6.1.2.20.4.3.7
This object provides the CRC code for the Factory data.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cebcalculateCRC 1.3.6.1.4.1.1166.6.1.2.20.4.3.8
This object indicates which of the Enums will have the CRC calculated.
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER factory(1), na(2), alarm(3)  

cebhourMeter 1.3.6.1.4.1.1166.6.1.2.20.4.3.9
This object provides the hour meter reading of the module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cebflashPrgCntA 1.3.6.1.4.1.1166.6.1.2.20.4.3.10
This object provides the number of times Bank 1 flash has been programmed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cebflashPrgCntB 1.3.6.1.4.1.1166.6.1.2.20.4.3.11
This object provides the number of times Bank 1 flash has been programmed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cebflashBankARev 1.3.6.1.4.1.1166.6.1.2.20.4.3.12
This object provides the revision of flash bank 0. The rev is 2 characters.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

cebflashBankBRev 1.3.6.1.4.1.1166.6.1.2.20.4.3.13
This object provides the revision of flash bank 1. The rev is 2 characters.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

trapCEBConfigChangeInteger 1
This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapCEBConfigChangeDisplayString 2
This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapCEBfanCurrentAlarm 3
This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapCEBModuleTempAlarm 4
This trap is issued when the Module Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapCEBFlashAlarm 5
This trap is issued when the Laser Modules detects an error during Flash memory operations.
TRAP-TYPE    

trapCEBBankBootAlarm 6
This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1.
TRAP-TYPE    

trapCEBAlarmDataCRCAlarm 7
This trap is issued when the Alarm Data CRC is incorrect.
TRAP-TYPE    

trapCEBFactoryDataCRCAlarm 8
This trap is issued when the Factory Data CRC is incorrect.
TRAP-TYPE