Juniper-AUTOCONFIGURE-MIB
File:
Juniper-AUTOCONFIGURE-MIB.mib (13748 bytes)
Imported modules
Imported symbols
Defined Types
JuniAutoConfEncaps |
|
Encapsulated protocol type. |
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
ip(0), ppp(1), pppoe(17), bridgedEthernet(19) |
|
JuniAutoConfEntry |
|
SEQUENCE |
|
|
|
|
juniAutoConfIfIndex |
InterfaceIndex |
|
|
juniAutoConfEncaps |
JuniAutoConfEncaps |
|
|
juniAutoConfEnable |
JuniEnable |
|
|
juniAutoConfLockoutSupported |
TruthValue |
|
|
juniAutoConfLockoutMin |
Integer32 |
|
|
juniAutoConfLockoutMax |
Integer32 |
|
|
juniAutoConfLockoutTime |
Integer32 |
|
|
juniAutoConfLockoutElapsedTime |
Integer32 |
|
|
juniAutoConfNextLockoutTime |
Integer32 |
|
Defined Values
juniAutoConfMIB |
1.3.6.1.4.1.4874.2.2.48 |
The Auto-Configuration MIB for the Juniper Networks enterprise. |
MODULE-IDENTITY |
|
|
|
juniAutoConfTable |
1.3.6.1.4.1.4874.2.2.48.1.1.1 |
Configures recognition of incoming data encapsulation types that
trigger autoconfiguration on an interface. Also, configures the
time range that the encapsulation type will be locked-out from
recognition in the event of an error in creating an interface of
the encapsulation type. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
JuniAutoConfEntry |
|
juniAutoConfEntry |
1.3.6.1.4.1.4874.2.2.48.1.1.1.1 |
Configures recognition of an incoming data encapsulation type that
triggers autoconfiguration on an interface. Also, configures the
time range that the encapsulation type will be locked-out from
recognition in the event of an error in creating an interface of
the encapsulation type. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
JuniAutoConfEntry |
|
|
juniAutoConfIfIndex |
1.3.6.1.4.1.4874.2.2.48.1.1.1.1.1 |
The ifIndex of the interface to which the autoconfiguration information
in this entry applies. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
InterfaceIndex |
|
|
juniAutoConfEncaps |
1.3.6.1.4.1.4874.2.2.48.1.1.1.1.2 |
The encapsulated protocol type to which the autoconfiguration
information in this entry applies. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
JuniAutoConfEncaps |
|
|
juniAutoConfEnable |
1.3.6.1.4.1.4874.2.2.48.1.1.1.1.3 |
When enabled, permits autoconfiguration of the specified interface when
the specified encapsulation is recognized in an incoming data frame. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
JuniEnable |
|
|
juniAutoConfLockoutSupported |
1.3.6.1.4.1.4874.2.2.48.1.1.1.1.4 |
Indicates whether lockout is supported for the specified
encapsulation type for the specified interface. If lockout is
supported, then juniAutoConfLockoutMin, juniAutoConfLockoutMax,
juniAutoConfLockoutTime, juniAutoConfLockoutElapsedTime, and
juniAutoConfNextLockoutTime are valid and supported in this entry. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
juniAutoConfLockoutMin |
1.3.6.1.4.1.4874.2.2.48.1.1.1.1.5 |
The lower bound, in seconds, of the time range used to specify
the duration of the lockout of the encapsulation type from
recognition for the specified interface. This only takes effect
if juniAutoConfEnable is set to enable for the encapsulation type
for this interface.
The ability to lockout the specified encapsulation type from
recognition in the event of an error in creating an interface of
the encapsulation type is enabled by default. The initial lockout
duration is this object's value and increases exponentially for
each failure that occurs for the specified encapsulation type
for the specified interface within the greater of 15 minutes
and juniAutoConfLockoutMax. The lockout duration for the specified
encapsulation type will not exceed juniAutoConfLockoutMax. If the
time between creation errors for the specified encapsulation type
for the specified interface is greater than the greater of 15
minutes and juniAutoConfigLockoutMax, then the lockout duration
reverts to this object's value.
To disable the ability to lockout the specified encapsulation type
from recognition in the event of an error in creating an interface
of the encapsulation type for the specified interface, the value of
this object and juniAutoConfLockoutMax must be set to 0. It is not
recommended that this lockout feature be disabled except for
debugging purposes. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..86400 |
|
juniAutoConfLockoutMax |
1.3.6.1.4.1.4874.2.2.48.1.1.1.1.6 |
The upper bound, in seconds, of the time range used to specify
the duration of the lockout of the encapsulation type from
recognition for the specified interface. This value must equal
or exceed the value for juniAutoConfLockoutMin. This only takes
effect if juniAutoConfEnable is set to enable for the encapsulation
type for this interface.
The ability to lockout the specified encapsulation type from
recognition in the event of an error in creating an interface of
the encapsulation type is enabled by default. The initial lockout
duration is juniAutoConfLockoutMin and increases exponentially for
each failure that occurs for the specified encapsulation type
for the specified interface within the greater of 15 minutes
and this object's value. The lockout duration for the specified
encapsulation type will not exceed this object's value. If the
time between creation errors for the specified encapsulation type
for the specified interface is greater than the greater of 15
minutes and this object's value, then the lockout duration
reverts to juniAutoConfigLockoutMin.
To disable the ability to lockout the specified encapsulation type
from recognition in the event of an error in creating an interface
of the encapsulation type for the specified interface, the value of
this object and juniAutoConfLockoutMin must be set to 0. It is not
recommended that this lockout feature be disabled except for
debugging purposes. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..86400 |
|
juniAutoConfLockoutTime |
1.3.6.1.4.1.4874.2.2.48.1.1.1.1.7 |
The time duration, in seconds, currently used to lockout the
specified encapsulation type from recognition for the specified
interface. The reported value is within the range specified by
juniAutoConfLockoutMin and juniAutoConfLockoutMax. A value of 0
indicates that no lockout is occurring for the encapsulation type
for the specified interface. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..86400 |
|
juniAutoConfLockoutElapsedTime |
1.3.6.1.4.1.4874.2.2.48.1.1.1.1.8 |
The elapsed time, in seconds, that the specified encapsulation type
has been locked-out from recognition for the specified interface.
Its value will not exceed that of juniAutoConfLockoutTime. A value of
0 indicates that no lockout is occurring for the encapsulation type
for the specified interface. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..86400 |
|
juniAutoConfNextLockoutTime |
1.3.6.1.4.1.4874.2.2.48.1.1.1.1.9 |
The time duration, in seconds, that will be used to lockout the
specified encapsulation type from recognition for the specified
interface for the next event that results in a lockout condition.
The reported value is within the range specified by
juniAutoConfLockoutMin and juniAutoConfLockoutMax. When
juniAutoConfEnable is set to enable, a value of 0 indicates that
lockout is prevented from occurring for the encapsulation type
for the specified interface (i.e., juniAutoConfLockoutMin and
juniAutoConfLockoutMax are both set to 0). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..86400 |
|
juniAutoConfCompliance |
1.3.6.1.4.1.4874.2.2.48.4.1.1 |
Obsolete compliance statement for systems supporting enabling of
autoconfiguration operation. This statement was obsoleted when
encapsulation type lockout objects were added. |
Status: obsolete |
Access: read-only |
MODULE-COMPLIANCE |
|
|
|
juniAutoConfCompliance2 |
1.3.6.1.4.1.4874.2.2.48.4.1.2 |
The compliance statement for systems supporting enabling of
autoconfiguration operation. |
Status: current |
Access: read-only |
MODULE-COMPLIANCE |
|
|
|
juniAutoConfGroup |
1.3.6.1.4.1.4874.2.2.48.4.2.1 |
Obsoleted collection of objects providing management of
autoconfiguration enabling in a Juniper product. This group
became obsolete when Encapsulation Type Lockout support was added. |
Status: obsolete |
Access: read-only |
OBJECT-GROUP |
|
|
|
juniAutoConfGroup2 |
1.3.6.1.4.1.4874.2.2.48.4.2.2 |
The basic collection of objects providing management of
autoconfiguration enabling in a Juniper product. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|