HW-IMAPV2NORTHBOUND-TRAP-MIB
File:
HW-IMAPV2NORTHBOUND-TRAP-MIB.mib (37421 bytes)
Imported modules
Imported symbols
Defined Values
huawei |
1.3.6.1.4.1.2011 |
This MIB defines the managed objects that are used
by the function interfaces of the SNMP Northbound
Interface. |
MODULE-IDENTITY |
|
|
|
products |
1.3.6.1.4.1.2011.2 |
OBJECT IDENTIFIER |
|
|
|
hwNmAgent |
1.3.6.1.4.1.2011.2.15.1 |
OBJECT IDENTIFIER |
|
|
|
hwNmFault |
1.3.6.1.4.1.2011.2.15.1.3 |
OBJECT IDENTIFIER |
|
|
|
thirdNMSFaultFilter |
1.3.6.1.4.1.2011.2.15.1.3.5 |
IP:Port:AlarmLevelFilter:AlarmCategoryFilter
AlarmLevelFilter = xxxx (Critical, Major, Minor, Warning) (1 - filter, 0 - report)
AlarmCategoryFilter = yyyyyy (Event, Fault, Recovery, Acknowledge, UnAcknowledge, Change) (1 - filter, 0 - report)
Both AlarmLevelFilter and AlarmCategoryFilter are optional and both or any one can be set
E.g.: 10.18.17.28:9999:0110:100000
Only events of major and minor severity will be send to the OSS [10.18.17.28:9999] and rest filtered.
The format to specify only AlarmLevelFilter is:
10.18.17.28:9999:0110
The format to specify only AlarmCategoryFilter is:
10.18.17.28:9999::100000
Get attempt on this node will result in error. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(1..255) |
|
hwNmClearAlarms |
1.3.6.1.4.1.2011.2.15.1.3.6 |
This provides the functionality of clearing alarms to third party NMS.
The alarms can be cleared based on alarm serial number.
Multiple serial numbers are separated by comma(,).
Alarms serial number(s)are of type unsigned long and
incompatible types are automatically considered
as invalid serial number(s). Get attempt on this node
will result in error.
Output: Serial number(s) of alarms which could not be
cleared. This also contains Alarm serial number(s)
with incorrect syntax. If all alarms are successfully
cleared then output is blank. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(1..2048) |
|
hwNmAcknowledgeAlarms |
1.3.6.1.4.1.2011.2.15.1.3.7 |
This provides the functionality of acknowledging alarms to third party NMS.
The alarms can be acknowledged based on alarm serial number.
Multiple serial numbers are separated by comma(,).
Alarms serial number(s) are of type unsigned long and
incompatible types are automatically considered
as invalid serial number(s). Get attempt on this node
will result in error.
Output: Serial number(s) of alarms which could not be
acknowledged. This also contains Alarm serial number(s)
with incorrect syntax. If all alarms are successfully
acknowledged then output is blank. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(1..2048) |
|
hwNmUnAcknowledgeAlarms |
1.3.6.1.4.1.2011.2.15.1.3.8 |
This provides the functionality of unacknowledging alarms to third party NMS.
The alarms can be unacknowledged based on alarm serial number.
Multiple serial numbers are separated by comma(,).
Alarms serial number(s) are of type unsigned long and
incompatible types are automatically considered
as invalid serial number(s). Get attempt on this node
will result in error.
Output: Serial number(s) of alarms which could not be
unacknowledged. This also contains Alarm serial number(s)
with incorrect syntax. If all alarms are successfully
unacknowledged then output is blank. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(1..2048) |
|
hwNmNorthboundEventTrap |
1.3.6.1.4.1.2011.2.15.1.7.1.0 |
Event Traps |
Status: current |
Access: read-write |
OBJECT-IDENTITY |
|
|
|
hwNmNorthboundNEName |
1.3.6.1.4.1.2011.2.15.1.7.1.1 |
The name of network element,string (255) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(1..255) |
|
hwNmNorthboundNEType |
1.3.6.1.4.1.2011.2.15.1.7.1.2 |
Device type of element,string(64) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..64) |
|
hwNmNorthboundObjectInstance |
1.3.6.1.4.1.2011.2.15.1.7.1.3 |
Instance of element,such as number of Rack, Frame, Slot, Subslot, Port and so on,string(255) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..255) |
|
hwNmNorthboundEventType |
1.3.6.1.4.1.2011.2.15.1.7.1.4 |
Type of Event,string(64) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..64) |
|
hwNmNorthboundEventTime |
1.3.6.1.4.1.2011.2.15.1.7.1.5 |
Time at which the alarm was generated,string(64).
It can be of any of the following formats:
1. Local Time without timezone information - 'YYYY/MM/DD - hh:mm:ss'
2. UTC Time - 'YYYY/MM/DD - hh:mm:ssZ'
3. Local Time with timezone information - 'YYYY/MM/DD - hh:mm:ss,hh:mmTZ[DST]'
where TZ stands for timezone information. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..64) |
|
hwNmNorthboundProbableCause |
1.3.6.1.4.1.2011.2.15.1.7.1.6 |
Probable cause of the alarm, string(255) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..4096) |
|
hwNmNorthboundSeverity |
1.3.6.1.4.1.2011.2.15.1.7.1.7 |
Level of Alarm., string(64)
It can be any of the following: Critical, Major, Minor, Warning, Indeterminate. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..64) |
|
hwNmNorthboundEventDetail |
1.3.6.1.4.1.2011.2.15.1.7.1.8 |
Alarm ID and detail information, string(4096) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..4096) |
|
hwNmNorthboundAdditionalInfo |
1.3.6.1.4.1.2011.2.15.1.7.1.9 |
Additional information of device, such as Country, City and so on, string(255) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..255) |
|
hwNmNorthboundFaultFlag |
1.3.6.1.4.1.2011.2.15.1.7.1.10 |
The flag which specifies whether the alarm is an Event, Fault, Recovery, Acknowledge
Unacknowledge or Change. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..64) |
|
hwNmNorthboundFaultFunction |
1.3.6.1.4.1.2011.2.15.1.7.1.11 |
The function type of the alarm.It can be one of these values:'Power','Environment','Signal','Relay','Hardware','Software','Run','Communication','Service','Processerror','UNKNOWN_FUNC_TYPE' |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..64) |
|
hwNmNorthboundProbableRepair |
1.3.6.1.4.1.2011.2.15.1.7.1.14 |
Alarm repair recommendations. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..4096) |
|
hwNmNorthboundResourceIDs |
1.3.6.1.4.1.2011.2.15.1.7.1.15 |
The ID of the resource. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(1..255) |
|
hwNmNorthboundsAdditionalVB1 |
1.3.6.1.4.1.2011.2.15.1.7.1.16 |
Additional information of the alarm. These 8 fields are decided by configuration in snmpsvc.xml |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(1..255) |
|
hwNmNorthboundsAdditionalVB2 |
1.3.6.1.4.1.2011.2.15.1.7.1.17 |
Additional information of the alarm. These 8 fields are decided by configuration in snmpsvc.xml |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(1..255) |
|
hwNmNorthboundsAdditionalVB3 |
1.3.6.1.4.1.2011.2.15.1.7.1.18 |
Additional information of the alarm. These 8 fields are decided by configuration in snmpsvc.xml |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(1..255) |
|
hwNmNorthboundsAdditionalVB4 |
1.3.6.1.4.1.2011.2.15.1.7.1.19 |
Additional information of the alarm. These 8 fields are decided by configuration in snmpsvc.xml |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(1..255) |
|
hwNmNorthboundsAdditionalVB5 |
1.3.6.1.4.1.2011.2.15.1.7.1.20 |
Additional information of the alarm. These 8 fields are decided by configuration in snmpsvc.xml |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(1..255) |
|
hwNmNorthboundsAdditionalVB6 |
1.3.6.1.4.1.2011.2.15.1.7.1.21 |
Additional information of the alarm. These 8 fields are decided by configuration in snmpsvc.xml |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(1..255) |
|
hwNmNorthboundsAdditionalVB7 |
1.3.6.1.4.1.2011.2.15.1.7.1.22 |
Additional information of the alarm. These 8 fields are decided by configuration in snmpsvc.xml |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(1..255) |
|
hwNmNorthboundsAdditionalVB8 |
1.3.6.1.4.1.2011.2.15.1.7.1.23 |
Additional information of the alarm. These 8 fields are decided by configuration in snmpsvc.xml |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(1..255) |
|
hwNmNorthboundEventName |
1.3.6.1.4.1.2011.2.15.1.7.1.24 |
The name of event,string (4096) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..4096) |
|
hwNmNorthboundDeviceType |
1.3.6.1.4.1.2011.2.15.1.7.1.27 |
The Device Type ID of the alarm |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(1..255) |
|
hwNmNorthboundTrailName |
1.3.6.1.4.1.2011.2.15.1.7.1.28 |
TrailName effected by alarm |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(1..255) |
|
hwNmNorthboundRootAlarm |
1.3.6.1.4.1.2011.2.15.1.7.1.29 |
Specifies if the alarm is a root alarm
0 - Non-root alarm
1 - Root alarm |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hwNmNorthboundMaintainStatus |
1.3.6.1.4.1.2011.2.15.1.7.1.31 |
maintain status |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hwNmNorthboundKeepAlive |
1.3.6.1.4.1.2011.2.15.1.7.2.1 |
Keep Alive |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
hwNmNorthboundEventSynchronizationEndStatus |
1.3.6.1.4.1.2011.2.15.1.7.7.3.1 |
It shows the result of alarm synchronization.
1 means the alarm synchronization successfully ended.
2 means the alarm synchronization is stopped by the NMS's command.
3 means some error occured during the alarm synchronization. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
normalEnd(1), stopped(2), error(3) |
|
hwNmNorthboundEventSynchronizationCommandStart |
1.3.6.1.4.1.2011.2.15.1.7.7.4 |
This node is to be set to start the alarm synchronization.
The format to query alarms is:- IP:port:start time:end time
Query time can be UTC time, Local time or Local time with timezone.
Syntax for start time and end time is - YYYYMMDDhhmmss. The interpretation of the start time and end time depends on
'AlarmTimeFormat' parameter in /etc/conf/snmpsvc.xml file.
Query can be in any of the following formats:
1. Local time(AlarmTimeFormat = 0):
Format:- IP:port:start time:end time
Here, the start time and end time will be considered to be in local time format.
2. UTC time(AlarmTimeFormat = 1):
Format:- IP:port:start time:end time
Here, the start time and end time will be considered to be UTC format.
3. Local time with timezone(AlarmTimeFormat = 2):
Format:- IP:port:start time:end time:timezone:dstflag
Here, the user can mention the timezone and dst flag.
Format to mention timezone is +/-hh.mm
if dstflag is 0 - DST disabled, 1- DST enabled.
Format to omit dst flag:- IP:port:start time:end time:timezone, will consider the dstflag to be 0.
The agent will send alarm synchronization result to the IP and port specified which were raised between start time and end time.
If start time and end time are missing all alarms are reported.
Start time and end time both are optional.
If end time is missing current time of the EMS is taken as end time.
If end time is present start time is not optional, it means you cannot provide end time without specifying the start time.
If there is already a running alarm synchronization for that IP and port,it will return a commit fail error. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(1..255) |
|
hwNmNorthboundEventSynchronizationCommandStop |
1.3.6.1.4.1.2011.2.15.1.7.7.5 |
This node is to be set to stop the alarm synchronization.
It should be set as NMS's IP:port,and the agent will stop alarm synchronization for the IP and port specified.
If alarm synchronization is not in progress for the specified IP and port,it will return a commit fail error. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(1..255) |
|
hwNmNorthboundEventNotify |
1.3.6.1.4.1.2011.2.15.1.7.1.0.1 |
Notification for real-time alarm. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwNmNorthboundEventKeepAlive |
1.3.6.1.4.1.2011.2.15.1.7.2.0.2 |
Notification for keep alive traps. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwNmNorthboundEventNotifyCritical |
1.3.6.1.4.1.2011.2.15.1.7.1.0.3 |
Notification for real-time alarm whose level is Critical. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwNmNorthboundEventNotifyMajor |
1.3.6.1.4.1.2011.2.15.1.7.1.0.4 |
Notification for real-time alarm whose level is Major. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwNmNorthboundEventNotifyMinor |
1.3.6.1.4.1.2011.2.15.1.7.1.0.5 |
Notification for real-time alarm whose level is Minor. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
hwNmNorthboundEventNotifyWarning |
1.3.6.1.4.1.2011.2.15.1.7.1.0.6 |
Notification for real-time alarm whose level is Warning. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|