HUAWEI-ENT-VOICE-DIAGNOSE-MIB
File:
HUAWEI-ENT-VOICE-DIAGNOSE-MIB.mib (38748 bytes)
Imported modules
Imported symbols
Defined Types
HwEntCallerEmulateEntry |
|
SEQUENCE |
|
|
|
|
hwEntCallerEmulatePort |
Integer32 |
|
|
hwEntCallerEmulateOprType |
INTEGER |
|
|
hwEntCallerEmulateTelno |
DisplayString |
|
|
hwEntCallerEmulateStatus |
Integer32 |
|
HwEntCalledEmulateEntry |
|
SEQUENCE |
|
|
|
|
hwEntCalledEmulatePort |
Integer32 |
|
|
hwEntCalledEmulateOprType |
INTEGER |
|
|
hwEntCalledEmulateStatus |
Integer32 |
|
HwEntCallEmulateEntry |
|
SEQUENCE |
|
|
|
|
hwEntCallEmulateIndex |
Integer32 |
|
|
hwEntCallEmulateOprType |
INTEGER |
|
|
hwEntCallEmulateCallerPort |
Integer32 |
|
|
hwEntCallEmulateCalledPort |
Integer32 |
|
|
hwEntCallEmulateCalledTelno |
DisplayString |
|
|
hwEntCallEmulateStatus |
Integer32 |
|
|
hwEntCallEmulateResult |
Integer32 |
|
Defined Values
hwEntPotsCircuitTestOprType |
1.3.6.1.4.1.2011.5.25.314.1.1 |
Indicates the operation type. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
stop(1), start(2) |
|
hwEntPotsCircuitTestPort |
1.3.6.1.4.1.2011.5.25.314.1.2 |
Indicates the test port.
bits 31-24: reserved
bits 23-16: slot index
bits 15-8: subcard index
bits 7-0: port index
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hwEntPotsCircuitTestBusyFlag |
1.3.6.1.4.1.2011.5.25.314.1.3 |
Indicates the process method, when the test port is busy. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
cancel(1), busytest(2), force(3), defer(4) |
|
hwEntPotsCircuitTestTimeProc |
1.3.6.1.4.1.2011.5.25.314.1.5 |
Indicates the process method afert time out. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noTest(1), mandatoryTest(2) |
|
hwEntPotsCircuitTestStatus |
1.3.6.1.4.1.2011.5.25.314.1.6 |
Indicates the test result. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
normal(1), testfail(2), portbusy(3), outoftime(4), testingAbnormal(5), testcanceled(6) |
|
hwEntPotsCircuitTestDigitalVoltageResult |
1.3.6.1.4.1.2011.5.25.314.1.7 |
Indicates the test result of digital voltage. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
normal(1), abnormal(2), notTested(3) |
|
hwEntPotsCircuitTestLowBatteryResult |
1.3.6.1.4.1.2011.5.25.314.1.8 |
Indicates the test result of low battery. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
normal(1), abnormal(2), notTested(3) |
|
hwEntPotsCircuitTestHighBatteryResult |
1.3.6.1.4.1.2011.5.25.314.1.9 |
Indicates the test result of high battery. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
normal(1), abnormal(2), notTested(3) |
|
hwEntPotsCircuitTestPositiveBatteryResult |
1.3.6.1.4.1.2011.5.25.314.1.10 |
Indicates the test result of positive battery.
Default: enable(1) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
normal(1), abnormal(2), notTested(3) |
|
hwEntPotsCircuitTestVAGResult |
1.3.6.1.4.1.2011.5.25.314.1.11 |
Indicates the test result of a-ground voltage. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
normal(1), abnormal(2), notTested(3) |
|
hwEntPotsCircuitTestVBGResult |
1.3.6.1.4.1.2011.5.25.314.1.12 |
Indicates the test result of b-ground voltage. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
normal(1), abnormal(2), notTested(3) |
|
hwEntPotsCircuitTestLoopCurrentResult |
1.3.6.1.4.1.2011.5.25.314.1.13 |
Indicates the test result of loop current. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
normal(1), abnormal(2), notTested(3) |
|
hwEntPotsCircuitTestFeederVoltageResult |
1.3.6.1.4.1.2011.5.25.314.1.14 |
Indicates the test result of feeder voltage. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
normal(1), abnormal(2), notTested(3) |
|
hwEntPotsLoopTestOprType |
1.3.6.1.4.1.2011.5.25.314.2.1 |
Indicates the operation type |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
stop(1), start(2) |
|
hwEntPotsLoopTestPort |
1.3.6.1.4.1.2011.5.25.314.2.2 |
Indicates the test port.
bits 31-24: reserved
bits 23-16: slot index
bits 15-8: subcard index
bits 7-0: port index
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hwEntPotsLoopTestBusyFlag |
1.3.6.1.4.1.2011.5.25.314.2.3 |
Indicates the process method, when the test port is busy. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
cancel(1), busytest(2), force(3), defer(4) |
|
hwEntPotsLoopTestTimeOut |
1.3.6.1.4.1.2011.5.25.314.2.4 |
Indicates the time out of busy. (Unit: min)
Default: 30 |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..1440 |
|
hwEntPotsLoopTestTimeProc |
1.3.6.1.4.1.2011.5.25.314.2.5 |
Indicates the process method, after the time out of busy. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noTest(1), mandatoryTest(2) |
|
hwEntPotsLoopTestVoltage |
1.3.6.1.4.1.2011.5.25.314.2.6 |
Indicates the test result of voltage. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noSelect(1), select(2) |
|
hwEntPotsLoopTestResistance |
1.3.6.1.4.1.2011.5.25.314.2.7 |
Indicates the test result of resistance. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noSelect(1), select(2) |
|
hwEntPotsLoopTestCapacitance |
1.3.6.1.4.1.2011.5.25.314.2.8 |
Indicates the test result of capacitance. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noSelect(1), select(2) |
|
hwEntPotsLoopTestLoopResistance |
1.3.6.1.4.1.2011.5.25.314.2.9 |
Indicates the test result of loop resistance. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noSelect(1), select(2) |
|
hwEntPotsLoopTestInverseResistance |
1.3.6.1.4.1.2011.5.25.314.2.10 |
Indicates the test result of inverse resistance. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noSelect(1), select(2) |
|
hwEntPotsLoopTestStatus |
1.3.6.1.4.1.2011.5.25.314.2.11 |
Indicates the test status. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
normal(1), testFail(2), portBusy(3), outofTime(4), testingAbnormal(5), testCanceled(6) |
|
hwEntPotsLoopTestRAB |
1.3.6.1.4.1.2011.5.25.314.2.21 |
Indicates the a-b resistance. (Unit: ) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hwEntPotsLoopTestCAGnd |
1.3.6.1.4.1.2011.5.25.314.2.22 |
Indicates the a-ground capacitance. (Unit: F) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hwEntPotsLoopTestCBGnd |
1.3.6.1.4.1.2011.5.25.314.2.23 |
Indicates the b-ground capacitance. (Unit: F) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hwEntPotsLoopTestCAB |
1.3.6.1.4.1.2011.5.25.314.2.24 |
Indicates the a-b capacitance. (Unit: F) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hwEntPotsLoopTestLR |
1.3.6.1.4.1.2011.5.25.314.2.25 |
Indicates the loop resistance. (Unit: ) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hwEntPotsLoopTestMSocket |
1.3.6.1.4.1.2011.5.25.314.2.27 |
Indicates the MSocket. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
notConnected(1), connected(2) |
|
hwEntPotsPathTestPort |
1.3.6.1.4.1.2011.5.25.314.3.1 |
Indicates the test port.
bits 31-24: reserved
bits 23-16: slot index
bits 15-8: subcard index
bits 7-0: port index
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hwEntPotsPathTestMode |
1.3.6.1.4.1.2011.5.25.314.3.2 |
Indicates the test type. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
hardware(1), business(2) |
|
hwEntPotsPathTestAssistPort |
1.3.6.1.4.1.2011.5.25.314.3.3 |
Indicates the assist port.
bits 31-24: reserved
bits 23-16: slot index
bits 15-8: subcard index
bits 7-0: port index
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hwEntPotsPathTestOprType |
1.3.6.1.4.1.2011.5.25.314.3.5 |
Indicates the operation type. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
stop(1), start(2) |
|
hwEntLineTestACVolGate |
1.3.6.1.4.1.2011.5.25.314.4.1 |
Indicates the AC voltage gate. (Unit: v)
Default: 55 |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..2147483647 |
|
hwEntLineTestDCVolGate |
1.3.6.1.4.1.2011.5.25.314.4.2 |
Indicates the DC voltage gate. (Unit: v)
Default: 40 |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..2147483647 |
|
hwEntLineTestResistGate |
1.3.6.1.4.1.2011.5.25.314.4.3 |
Indicates the resistance gate. (Unit: )
Default: 20000 |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..2147483647 |
|
hwEntLineTestOffHookRABLow |
1.3.6.1.4.1.2011.5.25.314.4.4 |
Indicates the low limit of a-b resistance in off hook. (Unit: )
Default: 100 |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..2147483647 |
|
hwEntLineTestOffHookRABUp |
1.3.6.1.4.1.2011.5.25.314.4.5 |
Indicates the up limit of a-b resistance in off hook. (Unit: )
Default: 100000 |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..2147483647 |
|
hwEntLineTestLRLow |
1.3.6.1.4.1.2011.5.25.314.4.6 |
Indicates the low limit of loop resistance. (Unit: )
Default: 100 |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..2147483647 |
|
hwEntLineTestLRLUp |
1.3.6.1.4.1.2011.5.25.314.4.7 |
Indicates the up limit of loop resistance. (Unit: )
Default: 2000 |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..2147483647 |
|
hwEntLineTestSelfMixRAB |
1.3.6.1.4.1.2011.5.25.314.4.8 |
Indicates the a-b resistance of mix. (Unit: )
Default: 2000 |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..2147483647 |
|
hwEntLineTestInsRABLow |
1.3.6.1.4.1.2011.5.25.314.4.9 |
Indicates the low limit of a-b resistance. (Unit: )
Default: 2000 |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..2147483647 |
|
hwEntLineTestInsRABUp |
1.3.6.1.4.1.2011.5.25.314.4.10 |
Indicates the up limit of a-b resistance. (Unit: )
Default: 20000 |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..2147483647 |
|
hwEntLineTestCapACUpGate |
1.3.6.1.4.1.2011.5.25.314.4.11 |
Indicates the ground capacitance up gate. (Unit: nF)
Default: 700 |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..2147483647 |
|
hwEntLineTestCapACLowGate |
1.3.6.1.4.1.2011.5.25.314.4.13 |
Indicates the ground capacitance low gate. (Unit: nF)
Default: 350 |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..2147483647 |
|
hwEntLineTestAdjustCAB |
1.3.6.1.4.1.2011.5.25.314.4.15 |
Indicates the a-b adjest capacitance. (Unit: nF) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..10000000 |
|
hwEntLineTestAdjustCAG |
1.3.6.1.4.1.2011.5.25.314.4.16 |
Indicates the a-ground adjest capacitance. (Unit: nF) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..10000000 |
|
hwEntLineTestAdjustCBG |
1.3.6.1.4.1.2011.5.25.314.4.17 |
Indicates the b-ground adjest capacitance. (Unit: nF) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..10000000 |
|
hwEntLineTestAdjustRAB |
1.3.6.1.4.1.2011.5.25.314.4.18 |
Indicates the a-b adjest resistance. (Unit: ) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..10000000 |
|
hwEntLineTestAdjustCutPort |
1.3.6.1.4.1.2011.5.25.314.4.19 |
Indicates the adjest cut port.
bits 31-24: reserved
bits 23-16: slot index
bits 15-8: subcard index
bits 7-0: port index
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..10000000 |
|
hwEntLineTestAdjustSelfMixPort |
1.3.6.1.4.1.2011.5.25.314.4.20 |
Indicates the adjest self mix port.
bits 31-24: reserved
bits 23-16: slot index
bits 15-8: subcard index
bits 7-0: port index
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..10000000 |
|
hwEntCallerEmulateEntry |
1.3.6.1.4.1.2011.5.25.314.5.1 |
A list of hwEntCallerEmulateEntry objects.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
HwEntCallerEmulateEntry |
|
|
hwEntCallerEmulatePort |
1.3.6.1.4.1.2011.5.25.314.5.1.1 |
Indicates the caller port.
bits 31-24: reserved
bits 23-16: slot index
bits 15-8: subcard index
bits 7-0: port index
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hwEntCallerEmulateOprType |
1.3.6.1.4.1.2011.5.25.314.5.1.2 |
Indicates the operation type. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
stop(1), start(2) |
|
hwEntCalledEmulateEntry |
1.3.6.1.4.1.2011.5.25.314.6.1 |
A list of hwEntCalledEmulateEntry objects. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
HwEntCalledEmulateEntry |
|
|
hwEntCalledEmulatePort |
1.3.6.1.4.1.2011.5.25.314.6.1.1 |
Indicates the caller port.
bits 31-24: reserved
bits 23-16: slot index
bits 15-8: subcard index
bits 7-0: port index
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hwEntCalledEmulateOprType |
1.3.6.1.4.1.2011.5.25.314.6.1.2 |
Indicates the operation type. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
stop(1), start(2) |
|
hwEntCallEmulateEntry |
1.3.6.1.4.1.2011.5.25.314.7.1 |
A list of hwEntCallEmulateEntry objects. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
HwEntCallEmulateEntry |
|
|
hwEntCallEmulateOprType |
1.3.6.1.4.1.2011.5.25.314.7.1.2 |
Indicates the operation type. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
stop(1), start(2) |
|
hwEntPotsCircuitTestTrap |
1.3.6.1.4.1.2011.5.25.314.8.1 |
circuit test result. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
hwEntPotsLoopTestTrap |
1.3.6.1.4.1.2011.5.25.314.8.2 |
Loop test result. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
hwEntPotsPathTestTrap |
1.3.6.1.4.1.2011.5.25.314.8.3 |
Path test result. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
hwEntCallEmulateTrap |
1.3.6.1.4.1.2011.5.25.314.8.4 |
Call emulate result. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
hwEntVoiceDiagnoseCompliance |
1.3.6.1.4.1.2011.5.25.314.9.1.1 |
The compliance statement for systems supporting
the this module. |
Status: current |
Access: read-only |
MODULE-COMPLIANCE |
|
|
|
hwEntPotsCircuitTestGroup |
1.3.6.1.4.1.2011.5.25.314.9.2.1 |
The hwEntPotsCircuitTest group. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
hwEntPotsLoopTestGroup |
1.3.6.1.4.1.2011.5.25.314.9.2.2 |
The hwEntPotsLoopTest group. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
hwEntPotsPathTestGroup |
1.3.6.1.4.1.2011.5.25.314.9.2.3 |
The hwEntPotsPathTest group. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
hwEntLineTestConfigGroup |
1.3.6.1.4.1.2011.5.25.314.9.2.4 |
The EntLineTest Config group. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
hwEntCallerEmulateGroup |
1.3.6.1.4.1.2011.5.25.314.9.2.5 |
The EntCaller Emulate Group. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
hwEntCalledEmulateGroup |
1.3.6.1.4.1.2011.5.25.314.9.2.6 |
The EntCalled Emulate group. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
hwEntCallEmulateGroup |
1.3.6.1.4.1.2011.5.25.314.9.2.7 |
The EntCallEmulate group. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|