HM2-PWRMGMT-MIB
File:
HM2-PWRMGMT-MIB.mib (11281 bytes)
Imported modules
Imported symbols
Defined Types
Hm2PSEntry |
|
SEQUENCE |
|
|
|
|
hm2PSID |
Integer32 |
|
|
hm2PSState |
INTEGER |
|
Hm2PSUSlotInfoEntry |
|
SEQUENCE |
|
|
|
|
hm2PSUSlotIndex |
Integer32 |
|
|
hm2PSUSlotChassisTypeId |
INTEGER |
|
|
hm2PSUSlotManufacturerId |
INTEGER |
|
|
hm2PSUSlotManufacturerDate |
SnmpAdminString |
|
|
hm2PSUSlotSerialNumber |
SnmpAdminString |
|
|
hm2PSUSlotProductCode |
SnmpAdminString |
|
|
hm2PSUSlotDescription |
SnmpAdminString |
|
|
hm2PSUSlotCombinationType |
INTEGER |
|
|
hm2PSUSlotTemperatureRange |
INTEGER |
|
|
hm2PSUSlotRevisionId |
Integer32 |
|
Hm2PSUUnitInfoEntry |
|
SEQUENCE |
|
|
|
|
hm2PSUUnitIndex |
Integer32 |
|
|
hm2PSUUnitConverterType |
INTEGER |
|
|
hm2PSUUnitNumberOfInputs |
Integer32 |
|
|
hm2PSUUnitOutputType |
INTEGER |
|
|
hm2PSUUnitSystemBudget |
Integer32 |
|
|
hm2PSUUnitPoeBudget |
Integer32 |
|
|
hm2PSUUnitFanCount |
Integer32 |
|
|
hm2PSUUnitVoltageRange |
INTEGER |
|
|
hm2PSUUnitPowerInterruption |
INTEGER |
|
Defined Values
hm2PowerMgmtMib |
1.11.11 |
Hirschmann Power Management MIB.
Copyright (C) 2011. All Rights Reserved. |
MODULE-IDENTITY |
|
|
|
hm2PSTable |
1.11.11.1.1.1 |
This table contains all variables related to the power supply
units of the chassis/switch. For each power supply slot exists
one instance. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Hm2PSEntry |
|
hm2PSEntry |
1.11.11.1.1.1.1 |
The entry of the hm2PSTable. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Hm2PSEntry |
|
|
hm2PSID |
1.11.11.1.1.1.1.1 |
This index is used to identify the associated power supply
unit. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..8 |
|
hm2PSState |
1.11.11.1.1.1.1.2 |
Indicates the operational state of the associated power
supply. If the value of this variable changes, a hm2PowerSupply
trap is sent. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
present(1), defective(2), notInstalled(3), unknown(4) |
|
hm2PSUSlotInfoTable |
1.11.11.1.1.10 |
This table contains all EEPROM variables related to the power supply
slot modules of the chassis/switch. For each power supply slot module exists
one instance. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Hm2PSUSlotInfoEntry |
|
hm2PSUSlotInfoEntry |
1.11.11.1.1.10.1 |
The entry of the hm2PSUSlotInfoTable. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Hm2PSUSlotInfoEntry |
|
|
hm2PSUSlotIndex |
1.11.11.1.1.10.1.1 |
This index is used to identify the associated power supply
slot module. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..4 |
|
hm2PSUSlotChassisTypeId |
1.11.11.1.1.10.1.2 |
The chassis type id of the associated power supply
slot module. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(0), mach1020(1), mach4000(2), railswitch(3), grs(4) |
|
hm2PSUSlotManufacturerId |
1.11.11.1.1.10.1.3 |
The manufacturer id of the associated power supply
slot module. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(0), hirschmann(1) |
|
hm2PSUSlotManufacturerDate |
1.11.11.1.1.10.1.4 |
The manufacturer date of the associated power supply
slot module.
*** NOTE this is set to OBSOLETE *** |
Status: obsolete |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
SnmpAdminString |
|
|
hm2PSUSlotCombinationType |
1.11.11.1.1.10.1.8 |
The combination type of the associated power supply
slot module. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
only-on-psu1(0), psu1-sys-psu2-poe(1), psu1-poe-psu2-sys(2), two-separate-psus(3) |
|
hm2PSUSlotTemperatureRange |
1.11.11.1.1.10.1.9 |
The temperature range of the associated power supply
slot module. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
tr-0-60(0), tr-minus40-60(1), tr-minus40-70(2), tr-minus40-70cc(3), tr-minus40-85(4), tr-minus40-85cc(5) |
|
hm2PSUUnitInfoTable |
1.11.11.1.1.20 |
This table contains all EEPROM variables related to the power supply
slot module units. For each power supply slot module exists
up to two instances. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Hm2PSUUnitInfoEntry |
|
hm2PSUUnitInfoEntry |
1.11.11.1.1.20.1 |
The entry of the hm2PSUUnitInfoTable. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Hm2PSUUnitInfoEntry |
|
|
hm2PSUUnitIndex |
1.11.11.1.1.20.1.1 |
The number of PSU units on the associated power supply
slot module. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..2 |
|
hm2PSUUnitConverterType |
1.11.11.1.1.20.1.2 |
The converter type of the associated power supply
slot module unit. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
ac(1), dc(2) |
|
hm2PSUUnitOutputType |
1.11.11.1.1.20.1.4 |
The output type of the associated power supply
slot module unit. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
system(1), both(2), poe(3) |
|
hm2PSUUnitSystemBudget |
1.11.11.1.1.20.1.5 |
The system budget of the associated power supply
slot module unit. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..1000 |
|
hm2PSUUnitPoeBudget |
1.11.11.1.1.20.1.6 |
The Poe budget of the associated power supply
slot module unit. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..1000 |
|
hm2PSUUnitFanCount |
1.11.11.1.1.20.1.7 |
The fan count of the associated power supply
slot module unit. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..2 |
|
hm2PSUUnitVoltageRange |
1.11.11.1.1.20.1.8 |
The voltage range of the associated power supply
slot module unit. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
vr-18-60vdc(0), vr-24-60vdc(1), vr-24-48vdc(2), vr-60-250vdc-110-240vac(3), vr-48-54vdc-poe(4) |
|
hm2PSUUnitPowerInterruption |
1.11.11.1.1.20.1.9 |
The power interruption value of the associated power supply
slot module unit. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
yes(1), no(2) |
|
hm2PowerSupplyTrap |
1.11.11.0.1 |
This trap is sent when the value of hm2PSState has been changed. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|