Fore-tp25-MIB
File:
Fore-tp25-MIB.mib (7293 bytes)
Imported modules
Imported symbols
Defined Types
Tp25ConfEntry |
|
SEQUENCE |
|
|
|
|
tp25ConfBoard |
Integer32 |
|
|
tp25ConfModule |
Integer32 |
|
|
tp25ConfPort |
Integer32 |
|
|
tp25MediaType |
INTEGER |
|
|
tp25LoopbackConfig |
INTEGER |
|
|
tp25RxTiming |
INTEGER |
|
Tp25ErrorEntry |
|
SEQUENCE |
|
|
|
|
tp25ErrorBoard |
Integer32 |
|
|
tp25ErrorModule |
Integer32 |
|
|
tp25ErrorPort |
Integer32 |
|
|
tp25ErrorSymbol |
Counter32 |
|
Tp25AtmEntry |
|
SEQUENCE |
|
|
|
|
tp25AtmBoard |
Integer32 |
|
|
tp25AtmModule |
Integer32 |
|
|
tp25AtmPort |
Integer32 |
|
|
tp25AtmHCSs |
Counter32 |
|
|
tp25AtmRxCells |
Counter32 |
|
|
tp25AtmTxCells |
Counter32 |
|
Defined Values
foreTP25Module |
1.3.6.1.4.1.326.2.2.1.1.9 |
The foreTP25 Module supports all switchs that have
the 25.6Mbps UTP/STP port module. |
MODULE-IDENTITY |
|
|
|
tp25ConfTable |
1.3.6.1.4.1.326.2.2.1.1.9.1.1 |
A table of TP25(25.6Mbps UTP/STP switch port configuration
information. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Tp25ConfEntry |
|
tp25ConfEntry |
1.3.6.1.4.1.326.2.2.1.1.9.1.1.1 |
A table entry containing TP25 configuration information
for each port. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Tp25ConfEntry |
|
|
tp25ConfBoard |
1.3.6.1.4.1.326.2.2.1.1.9.1.1.1.1 |
The index of this port's switch board. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
tp25ConfModule |
1.3.6.1.4.1.326.2.2.1.1.9.1.1.1.2 |
The network module of this port. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
tp25ConfPort |
1.3.6.1.4.1.326.2.2.1.1.9.1.1.1.3 |
The number of this port. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
tp25LoopbackConfig |
1.3.6.1.4.1.326.2.2.1.1.9.1.1.1.5 |
This variable represents the loopback configuration of the
TP25 interface.
tp25NoLoop (1) means that the interface is not in a loopback
state.
tp25DiagLoop (2) means that the transmit data stream is looped
back to the receiver.
tp25LineLoop (3) also known as remote loopback, in this state
received data is transfered to upstream system as well as
looped back to the transmitter. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
tp25NoLoop(1), tp25DiagLoop(2), tp25LineLoop(3) |
|
tp25RxTiming |
1.3.6.1.4.1.326.2.2.1.1.9.1.1.1.6 |
This variable represents the type of the physical medium
connected to the TP25 interface:
tp25NoTimingPresent (1) means port is not receiving sync pulses.
tp25TimingPresent (2) means port is receiving sync pulses. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
tp25NoTimingPresent(1), tp25TimingPresent(2) |
|
tp25ErrorTable |
1.3.6.1.4.1.326.2.2.1.1.9.2.1 |
A table of TP25 error counters. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Tp25ErrorEntry |
|
tp25ErrorEntry |
1.3.6.1.4.1.326.2.2.1.1.9.2.1.1 |
A table entry containing TP25 error counters. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Tp25ErrorEntry |
|
|
tp25ErrorBoard |
1.3.6.1.4.1.326.2.2.1.1.9.2.1.1.1 |
The index of this port's switch board. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
tp25ErrorModule |
1.3.6.1.4.1.326.2.2.1.1.9.2.1.1.2 |
The network module of this port. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
tp25ErrorPort |
1.3.6.1.4.1.326.2.2.1.1.9.2.1.1.3 |
The number of this port. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
tp25ErrorSymbol |
1.3.6.1.4.1.326.2.2.1.1.9.2.1.1.4 |
The number of all undefined 5 bit symbols received. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
tp25AtmTable |
1.3.6.1.4.1.326.2.2.1.1.9.2.2 |
A table of TP25 ATM statistics information. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Tp25AtmEntry |
|
tp25AtmEntry |
1.3.6.1.4.1.326.2.2.1.1.9.2.2.1 |
A table entry containing TP25 ATM statistics information. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Tp25AtmEntry |
|
|
tp25AtmBoard |
1.3.6.1.4.1.326.2.2.1.1.9.2.2.1.1 |
The index of this port's switch board. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
tp25AtmModule |
1.3.6.1.4.1.326.2.2.1.1.9.2.2.1.2 |
The network module of this port. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
tp25AtmPort |
1.3.6.1.4.1.326.2.2.1.1.9.2.2.1.3 |
The number of this port. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
tp25AtmHCSs |
1.3.6.1.4.1.326.2.2.1.1.9.2.2.1.4 |
Number of header check sequence (HCS) error events.
The HCS is a CRC-8 calculation over the first 4 octets
of the ATM cell header. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
tp25AtmRxCells |
1.3.6.1.4.1.326.2.2.1.1.9.2.2.1.5 |
Number of ATM cells that were received. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
tp25AtmTxCells |
1.3.6.1.4.1.326.2.2.1.1.9.2.2.1.6 |
Number of non-null ATM cells that were transmitted. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|