ERICSSON-ELN-TRAP-MIB
File:
ERICSSON-ELN-TRAP-MIB.mib (9511 bytes)
Imported modules
Imported symbols
Defined Values
elnTrapMIB |
1.3.6.1.4.1.193.109.2 |
This MIB module defines the Traps for the ELN |
MODULE-IDENTITY |
|
|
|
elnTrap |
1.3.6.1.4.1.193.109.2.0 |
OBJECT IDENTIFIER |
|
|
|
elnStart |
1.3.6.1.4.1.193.109.2.0.1 |
The switch has started / restarted. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
elnLinkDown |
1.3.6.1.4.1.193.109.2.0.2 |
The agent has detected that ifOperStatus for one communication link
is about to enter the down state. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
elnLinkUp |
1.3.6.1.4.1.193.109.2.0.3 |
The agent has detected ifOperStatus for one communication links has left
down state and transitioned into another state. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
elnOverheat |
1.3.6.1.4.1.193.109.2.0.4 |
The on board temperature sensor has detected an overheat condition. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
elnFanFail |
1.3.6.1.4.1.193.109.2.0.5 |
One or more fans is not working. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
elnPowerSupplyFail |
1.3.6.1.4.1.193.109.2.0.6 |
One or more sources of power has failed.
Presumably a redundant power-supply has taken over. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
elnPowerBackupFail |
1.3.6.1.4.1.193.109.2.0.7 |
One or more sources of backup power has failed. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
elnCabinetDoorOpen |
1.3.6.1.4.1.193.109.2.0.8 |
The door to the cabinet has been opened. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
elnHighTrafficLoad |
1.3.6.1.4.1.193.109.2.0.9 |
The number of free Cell Descriptors in the network processor has
fallen below a threshold value. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
elnOverheatOK |
1.3.6.1.4.1.193.109.2.0.11 |
An on board temperature sensor has detected that the overheat
condition has ceased. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
elnFanOK |
1.3.6.1.4.1.193.109.2.0.12 |
The fan is working again after a failure. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
elnPowerSupplyOK |
1.3.6.1.4.1.193.109.2.0.13 |
All sources of power is working again after a failure. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
elnPowerBackupOK |
1.3.6.1.4.1.193.109.2.0.14 |
All sources of backup power is working again after a failure. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|