ELTEX-SMI
File:
ELTEX-SMI.mib (33361 bytes)
Imported modules
Imported symbols
Defined Values
eltex |
1.3.6.1.4.1.34300 |
The Structure of Management Information for Eltex Networks. |
MODULE-IDENTITY |
|
|
|
elHardware |
1.3.6.1.4.1.34300.1 |
The root of eltex hardware OIDs. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
elSoftware |
1.3.6.1.4.1.34300.2 |
The root of eltex software OIDs. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
eltrapGroup |
1.3.6.1.4.1.34300.3 |
The root of eltex traps objects. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
mc240StreamAlarmTrap |
1.3.6.1.4.1.34300.3.3.1 |
mc-240 stream alarm trap. Severity: alert |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mc240SyncAlarmTrap |
1.3.6.1.4.1.34300.3.3.2 |
mc-240 sync alarm trap. Severity: warning |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mc240ss7LinkAlarmTrap |
1.3.6.1.4.1.34300.3.3.3 |
mc-240 ss7 link alarm trap. Severity: alert |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mc240ss7LinksetAlarmTrap |
1.3.6.1.4.1.34300.3.3.4 |
mc-240 ss7 linkset alarm trap. Severity: critical |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mc240FileAlarmTrap |
1.3.6.1.4.1.34300.3.3.5 |
mc-240 file alarm trap. Severity: critical |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mc240CardAlarmTrap |
1.3.6.1.4.1.34300.3.3.6 |
mc-240 card alarm trap. Severity: critical |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mxlDPSAlarmTrap |
1.3.6.1.4.1.34300.3.3.7 |
mxl DSL DP system alarm trap |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mxlTELEAlarmTrap |
1.3.6.1.4.1.34300.3.3.8 |
mxl DSL DP system alarm trap |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mc240UPSAlarmTrap |
1.3.6.1.4.1.34300.3.3.9 |
mc240 UPS alarm trap |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mc240SensAlarmTrap |
1.3.6.1.4.1.34300.3.3.10 |
mc240 sensor alarm trap (mcTrapExState = sensors bit mask, param1=temp,C, param2=Hum,%) |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
dslamLinkDownTrap |
1.3.6.1.4.1.34300.3.3.11 |
dslam link down trap (mcTrapExState = link state, param1 = ADSLport) |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
dslamDSRateAlarmTrap |
1.3.6.1.4.1.34300.3.3.12 |
Downstream rate for dslam ADSL port change (mcTrapExState = 2-increase 1-decrease, param1 = ADSLport) |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
dslamUSRateAlarmTrap |
1.3.6.1.4.1.34300.3.3.13 |
Downstream rate for dslam ADSL port change (mcTrapExState = 2-increase 1-decrease, param1 = ADSLport) |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
ponONUAuthAlarmTrap |
1.3.6.1.4.1.34300.3.3.14 |
Bad registration ONU Event (mcTrapLParam1=Optical Interface Number, mcTrapDescr='description with MAC addr ONU') |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
ponEthAlarmTrap |
1.3.6.1.4.1.34300.3.3.15 |
Eth Link Down, mcTrapLParam1=Link Number, Description='GePON: Eth Link N down' |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
ponOpticalAlarmTrap |
1.3.6.1.4.1.34300.3.3.16 |
The optical link N (mcTrapLParam1) has no active devices |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
dslamOverheatAlarmTrap |
1.3.6.1.4.1.34300.3.3.17 |
overheat (mcTrapExState = 1 -> DSP, = 2 -> PWR, param1 = val of temp * 10) |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
dslamVoltageAlarmTrap |
1.3.6.1.4.1.34300.3.3.18 |
when voltage deviation become more 10% (param1 = number of voltage nominal mean 12, -12, 3.3, 2.5, 1.8, 1.25, 1.5, 1 correspondly, param2 - whole number part temperature value, param3 - decimal part temperature value ) |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
dslamSessionAlarmTrap |
1.3.6.1.4.1.34300.3.3.19 |
Trap sending when connection happen, mcTrapLParam1 - means connection from (0)-CLI (1)->Webs (2)->SNMP |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
dslamEthLinkAlarmTrap |
1.3.6.1.4.1.34300.3.3.20 |
Trap sending when switch port link DOWN, mcTrapLParam1 - means port num:
for mxa: 0 - p0; 1 - p1; 2 - p2; 3 - cpu; 4 - dsl0; 5 - sfp; 6 - dsl1;
for asl: 0 - lan; 3 - cpu; 4 - dsl0; 5 - dsl1; 6 - s0; 7 - s1 |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mc240StreamOkTrap |
1.3.6.1.4.1.34300.3.4.1 |
mc-240 stream ok trap. Severity: alert |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mc240SyncOkTrap |
1.3.6.1.4.1.34300.3.4.2 |
mc-240 sync ok trap. Severity: warning |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mc240ss7LinkOkTrap |
1.3.6.1.4.1.34300.3.4.3 |
mc-240 ss7 link ok trap. Severity: alert |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mc240ss7LinksetOkTrap |
1.3.6.1.4.1.34300.3.4.4 |
mc-240 ss7 linkset ok trap. Severity: critical |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mc240FileOkTrap |
1.3.6.1.4.1.34300.3.4.5 |
mc-240 file ok trap. Severity: critical |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mc240CardOkTrap |
1.3.6.1.4.1.34300.3.4.6 |
mc-240 card trap. Severity: critical |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mxlDPSOkTrap |
1.3.6.1.4.1.34300.3.4.7 |
mxl DSL DP system alarm trap (normal state) |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mxlTELEOkTrap |
1.3.6.1.4.1.34300.3.4.8 |
mxl DSL DP system alarm trap (normal state) |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mc240UPSOkTrap |
1.3.6.1.4.1.34300.3.4.9 |
mc240 UPS alarm trap (normal state) |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mc240SensOkTrap |
1.3.6.1.4.1.34300.3.4.10 |
mc240 sensor alarm trap (normal state) |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
dslamLinkUpTrap |
1.3.6.1.4.1.34300.3.4.11 |
dslam link up trap (mcTrapExState = link state == 0, param1 = ADSLport) |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
dslamDSRateOkTrap |
1.3.6.1.4.1.34300.3.4.12 |
Downstream rate for dslam ADSL port change (mcTrapExState = 0-reate not change, param1 = ADSLport) |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
dslamUSRateOkTrap |
1.3.6.1.4.1.34300.3.4.13 |
Downstream rate for dslam ADSL port change (mcTrapExState = 0-reate not change, param1 = ADSLport) |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
ponONUAuthOkTrap |
1.3.6.1.4.1.34300.3.4.14 |
Normal registration ONU Event (mcTrapLParam1=Optical Interface Number, mcTrapDescr='description with MAC addr ONU') |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
ponEthOkTrap |
1.3.6.1.4.1.34300.3.4.15 |
Eth Link Up, mcTrapLParam1=Link Number, Description='GePON: Eth Link N up' |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
ponOpticalOkTrap |
1.3.6.1.4.1.34300.3.4.16 |
The optical link N (mcTrapLParam1) has M (mcTrapLParam2) active devices |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
dslamOverheatOkTrap |
1.3.6.1.4.1.34300.3.4.17 |
overheat (mcTrapExState = 1 -> DSP, = 2 -> PWR, param1 = val of temp * 10) |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
dslamVoltageOkTrap |
1.3.6.1.4.1.34300.3.4.18 |
when voltage deviation become less 10% (param1 = number of voltage nominal mean 12, -12, 3.3, 2.5, 1.8, 1.25, 1.5, 1 correspondly, param2 - whole number part temperature value, param3 - decimal part temperature value ) |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
dslamSessionOkTrap |
1.3.6.1.4.1.34300.3.4.19 |
Trap sending when connection closed, mcTrapLParam1 - means disconnection from (0)-CLI (1)->Webs (2)->SNMP |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
dslamEthLinkOkTrap |
1.3.6.1.4.1.34300.3.4.20 |
Trap sending when switch port link UP, mcTrapLParam1 - means port num:
for mxa: 0 - p0; 1 - p1; 2 - p2; 3 - cpu; 4 - dsl0; 5 - sfp; 6 - dsl1;
for asl: 0 - lan; 3 - cpu; 4 - dsl0; 5 - dsl1; 6 - s0; 7 - s1 |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mcTrapExState |
1.3.6.1.4.1.34300.3.5.1 |
state (additional state) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
mcTrapLParam1 |
1.3.6.1.4.1.34300.3.5.2 |
param-1 (slot or index) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
mcTrapLParam2 |
1.3.6.1.4.1.34300.3.5.3 |
param-2 (port or index) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
mcTrapLParam3 |
1.3.6.1.4.1.34300.3.5.4 |
param-3 (other index) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
mcTrapID |
1.3.6.1.4.1.34300.3.5.5 |
ID (pbx trap id) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
mcTrapDescr |
1.3.6.1.4.1.34300.3.5.6 |
Alarm description |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
mcTrapRestoredAlarmID |
1.3.6.1.4.1.34300.3.5.7 |
If this restore event then here writed Alarm ID. If this alarm event then mcTrapRestoredAlarmID=0. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
mcTrapSyncType |
1.3.6.1.4.1.34300.3.5.8 |
Type of trap: 0 - Normal; 1 - Journal alarms; 2 - Active alarms |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
omsOperationCommandAlarm |
1.3.6.1.4.1.34300.3.20.1 |
mcTrapLParam1 = command ;
mcTrapLParam2 = filetype
mcTrapDescr = Description of operarion:
DeviceName,
command ,
tftp host,
config filename,
status=Error,
cause of error |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
omsOperationCommandOk |
1.3.6.1.4.1.34300.3.21.1 |
mcTrapLParam1 = command ;
mcTrapLParam2 = filetype
mcTrapDescr = Description of operarion:
DeviceName,
command ,
tftp host,
config filename,
status=Ok |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mp800mkMPStatusAlarmTrap |
1.3.6.1.4.1.34300.3.8.1 |
MP operation error. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mp800mkInpParmAlarmTrap |
1.3.6.1.4.1.34300.3.8.2 |
Incorrect input parameters. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mp800mkUEPConfAlarmTrap |
1.3.6.1.4.1.34300.3.8.3 |
UEP configuration error. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mp800mkTMAlarmTrap |
1.3.6.1.4.1.34300.3.8.4 |
Temperature measurement error. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mp800mkACVMAlarmTrap |
1.3.6.1.4.1.34300.3.8.5 |
ACV measurement error. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mp800mkIbatMAlarmTrap |
1.3.6.1.4.1.34300.3.8.6 |
Battery current measurement error. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mp800mkVbatMAlarmTrap |
1.3.6.1.4.1.34300.3.8.7 |
Battery voltage measurement error. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mp800mkVbatChAlarmTrap |
1.3.6.1.4.1.34300.3.8.8 |
Can't change (increase or decrease) battery voltage. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mp800mkRlsDevAlarmTrap |
1.3.6.1.4.1.34300.3.8.9 |
Release device is off (battery disconnected). |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mp800mkDVcellAlarmTrap |
1.3.6.1.4.1.34300.3.8.10 |
Battery cell voltage spread is out of range. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mp800mkACVAlarmTrap |
1.3.6.1.4.1.34300.3.8.11 |
AC voltage is out of range. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mp800mkBatChargeAlarmTrap |
1.3.6.1.4.1.34300.3.8.12 |
Battery is close to total discharge. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mp800mkIloadAlarmTrap |
1.3.6.1.4.1.34300.3.8.13 |
Load current is out of range. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mp800mkIbatChAlarmTrap |
1.3.6.1.4.1.34300.3.8.14 |
Battery charge current is too high. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mp800mkSuppAlarmTrap |
1.3.6.1.4.1.34300.3.8.15 |
Power supply from battery. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mp800mkBatConnAlarmTrap |
1.3.6.1.4.1.34300.3.8.16 |
Battery is disconnected from MPs' output. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mp800mkMPStatusOkTrap |
1.3.6.1.4.1.34300.3.9.1 |
MP operation OK. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mp800mkInpParmOkTrap |
1.3.6.1.4.1.34300.3.9.2 |
Input parameters OK. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mp800mkUEPConfOkTrap |
1.3.6.1.4.1.34300.3.9.3 |
UEP configuration OK. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mp800mkTMOkTrap |
1.3.6.1.4.1.34300.3.9.4 |
Temperature measurement OK. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mp800mkACVMOkTrap |
1.3.6.1.4.1.34300.3.9.5 |
ACV measurement OK. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mp800mkIbatMOkTrap |
1.3.6.1.4.1.34300.3.9.6 |
Battery current measurement OK. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mp800mkVbatMOkTrap |
1.3.6.1.4.1.34300.3.9.7 |
Battery voltage measurement OK. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mp800mkVbatChOkTrap |
1.3.6.1.4.1.34300.3.9.8 |
Battery voltage changing OK. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mp800mkRlsDevOkTrap |
1.3.6.1.4.1.34300.3.9.9 |
Release device is on. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mp800mkDVcellOkTrap |
1.3.6.1.4.1.34300.3.9.10 |
Battery cell voltage spread is in range. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mp800mkACVOkTrap |
1.3.6.1.4.1.34300.3.9.11 |
AC voltage is in range. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mp800mkBatChargeOkTrap |
1.3.6.1.4.1.34300.3.9.12 |
Battery charge status is OK. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mp800mkIloadOkTrap |
1.3.6.1.4.1.34300.3.9.13 |
Load current is in range. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mp800mkIbatChOkTrap |
1.3.6.1.4.1.34300.3.9.14 |
Battery charge current is in range. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mp800mkSuppOkTrap |
1.3.6.1.4.1.34300.3.9.15 |
Power supply from MPs. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mp800mkBatConnOkTrap |
1.3.6.1.4.1.34300.3.9.16 |
Battery is connected to MPs' output. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
eltrapObjectGroup |
1.3.6.1.4.1.34300.3.101 |
Tok_String |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|