Defined Values
eltMesNotifications |
1.3.6.1.4.1.35265.1.23.0 |
This private MIB module defines Eltex's private notifications |
MODULE-IDENTITY |
|
|
|
i2cBusFailure |
1.3.6.1.4.1.35265.1.23.0.3 |
An I2C bus malfunction detected. It means that a lot of I2C bus I/O
transactions was completed unsuccessfully before and repairing efforts
were vain. It is a critical event, all I2C-controllable HW nodes are
unaccessible now. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
i2cBusOperational |
1.3.6.1.4.1.35265.1.23.0.4 |
An I2C bus is now operational. Appearance of this trap means that bus
operation was stick before and is repaired now. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
transThresholdWarning |
1.3.6.1.4.1.35265.1.23.0.5 |
Particular value of temperature, voltage, current, output power or
input power is outside of normal limits.
Alarm indicates conditions associated with an in-operational link.
Warning indicates conditions outside normally guaranteed bounds,
but not necessary causes link failures |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
transThresholdOK |
1.3.6.1.4.1.35265.1.23.0.6 |
Particular value of temperature, voltage, current, output power or
input power is inside of normal limits. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|