DNOS-POWER-ETHERNET-MIB
File:
DNOS-POWER-ETHERNET-MIB.mib (13331 bytes)
Imported modules
Imported symbols
Defined Types
AgentPethPsePortEntry |
|
SEQUENCE |
|
|
|
|
agentPethPowerLimit |
Gauge32 |
|
|
agentPethOutputPower |
Gauge32 |
|
|
agentPethOutputCurrent |
Gauge32 |
|
|
agentPethOutputVolts |
Gauge32 |
|
|
agentPethTemperature |
Gauge32 |
|
|
agentPethPowerLimitType |
INTEGER |
|
|
agentPethHighPowerEnable |
TruthValue |
|
|
agentPethPowerDetectionType |
INTEGER |
|
|
agentPethFaultStatus |
INTEGER |
|
|
agentPethPortReset |
INTEGER |
|
AgentPethMainPseEntry |
|
SEQUENCE |
|
|
|
|
agentPethMainPseLegacy |
TruthValue |
|
AgentPethPseEntry |
|
SEQUENCE |
|
|
|
|
agentPethPsePowerManagementMode |
INTEGER |
|
|
agentPethPseAutoResetEnable |
TruthValue |
|
Defined Values
fastPathpowerEthernetMIB |
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.15 |
This MIB Augments the POWER-ETHERNET-MIB created by the IETF Ethernet
Interfaces and Hub MIB Working Group for managing Power Source
Equipment (PSE). The objects in this MIB are intended to provide
additional objects for reporting information available to the hardware
on this platform which are not represented in the draft MIB. |
MODULE-IDENTITY |
|
|
|
agentPethPsePortTable |
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.15.1.1 |
A table of per-port information and configuration objects relating
to the power status of each port. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
AgentPethPsePortEntry |
|
agentPethPsePortEntry |
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.15.1.1.1 |
A collection of objects providing additional power information
and control parameters for the specified port. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
AgentPethPsePortEntry |
|
|
agentPethPowerLimit |
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.15.1.1.1.1 |
The configured maximum power this port can provide to an
attached device measured in Milliwatts. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
agentPethOutputPower |
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.15.1.1.1.2 |
The power this port is supplying to an attached device measured
in Milliwatts. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
agentPethOutputCurrent |
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.15.1.1.1.3 |
The current this port is supplying to an attached device measured
in Milliamps. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
agentPethOutputVolts |
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.15.1.1.1.4 |
The voltage this port is supplying to an attached device measured
in Volts. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
agentPethTemperature |
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.15.1.1.1.5 |
The temperature measured at this port of the PoE Controller. It is
measured in degree celcius. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
agentPethPowerLimitType |
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.15.1.1.1.6 |
Describes or controls the maximum power that a port can deliver
A value of dot3af(1) means that the port power limit is as per
the dot3af class of the PD attached.
A value of user(2) means that the port power limit is equal to the value
specified by agentPethPowerLimit |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
dot3af(1), user(2) |
|
agentPethHighPowerEnable |
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.15.1.1.1.7 |
true (1) The PSE port can deliver power up to 32Watts.
false(2) The PSE port can deliver power up to 18Watts |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
agentPethPowerDetectionType |
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.15.1.1.1.8 |
Describes PD detection mechanism performed by the PSE port.
A value of none(0) means no detection is done.
A value of legacy(1) means only legacy capacitive detection scheme is
used.
A value of 4ptdot3afonly(2) means that IEEE 802.3af 4point detection scheme
is used.
A value of 4ptdot3afandlegacy(3)means that IEEE 802.3af 4point detection scheme
is used and when that fails to detect a connected PD, legacity capacitive detection
is used.
A value of 2ptdot3afonly(4) means that IEEE 802.3af 2point detection scheme
is used.
A value of 2ptdot3afandlegacy(5)means that IEEE 802.3af 2point detection scheme
is used and when that fails to detect a connected PD, legacity capacitive detection
is used.
The value 'none' can not be forcibly set by the administrator. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
none(0), legacy(1), fourPtdot3afonly(2), fourPtdot3afandlegacy(3), twoPtdot3afonly(4), twoPtdot3afandlegacy(5) |
|
agentPethFaultStatus |
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.15.1.1.1.9 |
Describes the error description when the pse port is in fault status.
A value of none(0) specifies that the pse port is not in any error state.
A value of mpsAbsent(1) specifies that the pse port has detected and absence
of main power supply.
A value of short(2) specifies that the pse port has detected a short circuit
condition.
A value of overload(3) specifies that the pd connected to the pse port had tried
to draw more power than permissible by the hardware.
A value of powerDenied(4) specifies that the pse port has been denied power
because of shortage of power or due to administrative action. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
none(0), mpsAbsent(1), short(2), overload(3), powerDenied(4) |
|
agentPethPortReset |
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.15.1.1.1.10 |
A value of reset(1) is used to move the pse port dot3af state to idle. A
read on this object will always return the value none(0). The value none(0)
can not be forcibly set by the administrtor. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
none(0), reset(1) |
|
agentPethMainPseObjects |
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.15.1.2 |
OBJECT IDENTIFIER |
|
|
|
agentPethMainPseTable |
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.15.1.2.1 |
A table of objects that display and control attributes
of the main power source in a PSE device. Ethernet
switches are one example of boxes that would support
these objects.
Values of all read-write objects in this table are
persistent at restart/reboot. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
AgentPethMainPseEntry |
|
agentPethMainPseEntry |
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.15.1.2.1.1 |
A set of objects that display and control the Main
power of a PSE. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
AgentPethMainPseEntry |
|
|
agentPethMainPseLegacy |
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.15.1.2.1.1.1 |
Enable/Disable Legacy device detection. The
value true(1) means legacy devices are detected; the
value false(2) means legacy devices are not detected. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
agentPethPseTable |
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.15.1.3 |
A table of per-unit information and configuration objects relating
to the power configurtion for the entire pse unit. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
AgentPethPseEntry |
|
agentPethPseEntry |
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.15.1.3.1 |
A collection of objects providing additional power information
and control parameters for the specified pse unit. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
AgentPethPseEntry |
|
|
agentPethPsePowerManagementMode |
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.15.1.3.1.1 |
Describes or controls the power management algorithm used by the pse
to deliver power to the requesting PDsthat a pds.
A value of dot3af(1) means that the port power limit is as per
the dot3af class of the PD attached.
A value of user(2) means that the port power limit is equal to the value
specified by agentPethPowerLimit |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
none(0), dynamic(1), static(2) |
|
agentPethPseAutoResetEnable |
1.3.6.1.4.1.674.10895.5000.2.6132.1.1.15.1.3.1.2 |
true (1) The PSE port is reset with out administrator intervention whenver a
fault condition occurs.
false(2) Administrator has to reset the pse port whenver a fault condition
is detected. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|