AV-IC-ALARM-MIB
File:
AV-IC-ALARM-MIB.mib (8531 bytes)
Imported modules
Imported symbols
Defined Values
crm2 |
1.3.6.1.4.1.6889.1.4 |
OBJECT IDENTIFIER |
|
|
|
ic2 |
1.3.6.1.4.1.6889.1.4.1 |
OBJECT IDENTIFIER |
|
|
|
crm |
1.3.6.1.4.1.6889.2.4 |
OBJECT IDENTIFIER |
|
|
|
ic |
1.3.6.1.4.1.6889.2.4.1 |
OBJECT IDENTIFIER |
|
|
|
avICAlarmMIB |
1.3.6.1.4.1.6889.2.4.1.1 |
MIB objects for AIC alarm |
MODULE-IDENTITY |
|
|
|
avICAlarmIndex |
1.3.6.1.4.1.6889.2.4.1.1.1.1.1 |
An integer that acts as an Alarm Id to uniquely identify
each IC alarm. The alarm id starts at zero
when the sysUpTime starts at zero. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..4294967295 |
|
avICAlarmTime |
1.3.6.1.4.1.6889.2.4.1.1.1.1.2 |
The local Time at which Alarm was generated at the alarm source
identified by avICAlarmName/avICAlarmLocation.
This is a time-stamp based on alarm-generation
time at the source (IC server) -
not the sysUptime of the associated SNMP agent.
The time value is encoded by the source as an integer. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TimeTicks |
|
|
avICAlarmName |
1.3.6.1.4.1.6889.2.4.1.1.1.1.3 |
Interface name of the alarm source entity -
in form of interface name i.e. ServerName.Interface
(e.g. alarm.Alarm). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
avICAlarmLocation |
1.3.6.1.4.1.6889.2.4.1.1.1.1.4 |
The location (IP address and port) of the server/client
from where the alarm was generated.
The location is in the form of ip-address:port-number,
e.g. 192.168.6.185:7001. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
avICAlarmLocationIpAddress |
1.3.6.1.4.1.6889.2.4.1.1.1.1.5 |
Ip-Address of the location of the server/client
from where the alarm was generated |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
avICAlarmLocationPort |
1.3.6.1.4.1.6889.2.4.1.1.1.1.6 |
IP port-number of the server/client at avICAlarmLocationIpAddress
from where the alarm was generated |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
avICAlarmPriorityCritical |
1.3.6.1.4.1.6889.2.4.1.1.1.1.7 |
Importance of the alarm.
Pre-defined levels are emergency, high, info, low. Alarms with info priority are discarded
and alarms with other priority levels are mapped as shown following -
emergency --> critical(3) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
ItuPerceivedSeverity |
|
|
avICAlarmPriorityMajor |
1.3.6.1.4.1.6889.2.4.1.1.1.1.8 |
Importance of the alarm.
Pre-defined levels are emergency, high, info, low. Alarms with info priority are discarded
and alarms with other priority levels are mapped as shown following -
high --> major(4) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
ItuPerceivedSeverity |
|
|
avICAlarmPriorityMinor |
1.3.6.1.4.1.6889.2.4.1.1.1.1.9 |
Importance of the alarm.
Pre-defined levels are emergency, high, info, low. Alarms with info priority are discarded
and alarms with other priority levels are mapped as shown following -
low --> minor(5) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
ItuPerceivedSeverity |
|
|
avICAlarmDescription |
1.3.6.1.4.1.6889.2.4.1.1.1.1.10 |
Textual description of this alarm.
Actual cause of raising this alarm |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
avICAlarmEvent |
1.3.6.1.4.1.6889.2.4.1.1.2.1 |
IC Alarm event that encapsulates IC Alarm into SNMP Notification.
Make sure that the object (control variable) instances are
encoded as
sysUpTime.0 = <55556>,
snmpTrapOID.0 = avICAlarmNotifications.1 ,
avICAlarmTime.0=, avICAlarmName.0=,
avICAlarmLocation.0=,
(avICAlarmLocationIpAddress.0=,
avICAlarmLocationPort.0=<1234>,)
avICAlarmPriorityCritical.0=<3>
avICAlarmPriorityMajor.0=<4>
avICAlarmPriorityMinor.0=<5>
avICAlarmDescription.0=<00 00 00 00 00 ... >
in the varbind-list of the Notification PDU.
|
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
avICAlarmCompliance |
1.3.6.1.4.1.6889.2.4.1.1.3.1.1 |
The compliance statement |
Status: current |
Access: read-only |
MODULE-COMPLIANCE |
|
|
|
avICAlarmTrapObjectGroup |
1.3.6.1.4.1.6889.2.4.1.1.3.2.1 |
These objects are required to control traps
from IC Alarm Manager systems. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|