ZXR10-POE-MIB

File: ZXR10-POE-MIB.mib (8487 bytes)

Imported modules

SNMPv2-SMI

Imported symbols

OBJECT-TYPE Integer32 enterprises

Defined Types

DisplayString  
OCTET STRING    

PseEntry  
SEQUENCE    
  pseGroupIndex Integer32
  overTemperatureAutoRecovery INTEGER
  psePeakPower DisplayString
  psePeakPowerTime DisplayString
  pseCurrentTemperature DisplayString
  pseFirmwareVersion DisplayString
  pseCriticalPower DisplayString

PortEntry  
SEQUENCE    
  portEntryGroupIndex Integer32
  portEntryPortIndex Integer32
  interfaceCurrentPower DisplayString
  interfaceAvgPower DisplayString
  interfacePeakPower DisplayString
  interfacepeakPowerTime DisplayString
  enhancedMode INTEGER
  pdMaxPower INTEGER

Defined Values

zte 1.3.6.1.4.1.3902
OBJECT IDENTIFIER    

zxr10 1.3.6.1.4.1.3902.3
OBJECT IDENTIFIER    

zxr10POE 1.3.6.1.4.1.3902.3.319
OBJECT IDENTIFIER    

pseTable 1.3.6.1.4.1.3902.3.319.1
A table of objects that display and control attributes of the main power source in a PSE device. Ethernet switches are one example of boxes that would support these objects. Values of all read-write objects in this table are persistent at restart/reboot.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PseEntry

pseEntry 1.3.6.1.4.1.3902.3.319.1.1
A set of objects that display and control the Main power of a PSE.
Status: current Access: not-accessible
OBJECT-TYPE    
  PseEntry  

pseGroupIndex 1.3.6.1.4.1.3902.3.319.1.1.1
This variable uniquely identifies the group containing the port to which a power Ethernet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for non-modular devices. Furthermore, the same value MUST be used in this variable, pethMainPseGroupIndex, and pethNotificationControlGroupIndex to refer to a given box in a stack or module in the rack.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..2147483647  

overTemperatureAutoRecovery 1.3.6.1.4.1.3902.3.319.1.1.2
disable (0) An group which can not provide the overtemperature auto-recovery functions. enable(1) An group which can provide the overtemperature auto-recovery functions.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

psePeakPower 1.3.6.1.4.1.3902.3.319.1.1.3
Poe peak-power.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

psePeakPowerTime 1.3.6.1.4.1.3902.3.319.1.1.4
peak-power time.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

pseCurrentTemperature 1.3.6.1.4.1.3902.3.319.1.1.5
Poe current temperature.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

pseFirmwareVersion 1.3.6.1.4.1.3902.3.319.1.1.6
Poe firmware version.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

pseCriticalPower 1.3.6.1.4.1.3902.3.319.1.1.7
Poe critical-power.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

portTable 1.3.6.1.4.1.3902.3.319.2
A table of objects that display and control the power characteristics of power Ethernet ports on a Power Source Entity (PSE) device. This group will be implemented in managed power Ethernet switches and mid-span devices. Values of all read-write objects in this table are persistent at restart/reboot.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PortEntry

portEntry 1.3.6.1.4.1.3902.3.319.2.1
A set of objects that display and control the power characteristics of a power Ethernet PSE port.
Status: current Access: not-accessible
OBJECT-TYPE    
  PortEntry  

portEntryGroupIndex 1.3.6.1.4.1.3902.3.319.2.1.1
This variable uniquely identifies the group to which power Ethernet PSE is connected. Group means (box in the stack, module in a rack) and the value 1 MUST be used for non-modular devices. Furthermore, the same value MUST be used in this variable, pethPsePortGroupIndex, and pethNotificationControlGroupIndex to refer to a given box in a stack or module in a rack.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..2147483647  

portEntryPortIndex 1.3.6.1.4.1.3902.3.319.2.1.2
This variable uniquely identifies the power Ethernet PSE port within group pethPsePortGroupIndex to which the power Ethernet PSE entry is connected.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..2147483647  

interfaceCurrentPower 1.3.6.1.4.1.3902.3.319.2.1.3
The current power of the PSE port expressed in Watts.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

interfaceAvgPower 1.3.6.1.4.1.3902.3.319.2.1.4
The average power of the PSE port expressed in Watts.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

interfacePeakPower 1.3.6.1.4.1.3902.3.319.2.1.5
The peak power of the PSE port expressed in Watts.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

interfacepeakPowerTime 1.3.6.1.4.1.3902.3.319.2.1.6
The interface peak Power Time.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

enhancedMode 1.3.6.1.4.1.3902.3.319.2.1.7
enable (0) An interface which can provide the enhanced mode. disable(1) An interface which can not provide the enhanced mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(0), disable(1)  

pdMaxPower 1.3.6.1.4.1.3902.3.319.2.1.8
The max poe pd power: 15.4(0) 15.4W 4.0(1), 4.0W 7.0(2), 7.0W ext.18(3), 18W ext.27(4), 27W ext.30(5) 30W
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER fifteen-point-four(0), four(1), seven(2), eighteen(3), twenty-seven(4), thirty(5)