Wellfleet-T1-MIB

File: Wellfleet-T1-MIB.mib (6384 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC-1215
RFC1213-MIB Wellfleet-COMMON-MIB

Imported symbols

IpAddress Counter Gauge
TimeTicks Opaque enterprises
mgmt OBJECT-TYPE TRAP-TYPE
DisplayString mib-2 wfLine

Defined Types

WfT1Entry  
SEQUENCE    
  wfT1Delete INTEGER
  wfT1Disable INTEGER
  wfT1State INTEGER
  wfT1Slot INTEGER
  wfT1Connector INTEGER
  wfT1Madr OCTET STRING
  wfT1FrameType INTEGER
  wfT1LineBuildout INTEGER
  wfT1B8ZSSupport INTEGER
  wfT1ClockMode INTEGER
  wfT1MiniDacs DisplayString
  wfT1BipolarVios Counter
  wfT1FrameBitErrs Counter
  wfT1OutOfFrameErrs Counter
  wfT1SuperFrameErrs Counter
  wfT1RcvYelAlarms Counter
  wfT1RcvCarrierLoss Counter
  wfT1RcvRedAlarms Counter

Defined Values

wfT1Table 1.3.6.1.4.1.18.3.4.10
T1 line record
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfT1Entry

wfT1Entry 1.3.6.1.4.1.18.3.4.10.1
An entry in the T1 table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfT1Entry  

wfT1Delete 1.3.6.1.4.1.18.3.4.10.1.1
create/delete parameter, dflt = created
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER created(1), deleted(2)  

wfT1Disable 1.3.6.1.4.1.18.3.4.10.1.2
enable/disable parameter, dflt = enabled
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfT1State 1.3.6.1.4.1.18.3.4.10.1.3
line driver state variable, Not Present, Init, Up
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER up(1), init(3), notpresent(4)  

wfT1Slot 1.3.6.1.4.1.18.3.4.10.1.4
instance ID Slot, filled in by driver
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..14  

wfT1Connector 1.3.6.1.4.1.18.3.4.10.1.5
instance ID Connector, filled in by driver
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER one(1), two(2)  

wfT1Madr 1.3.6.1.4.1.18.3.4.10.1.6
Line mac address, filled in by driver
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wfT1FrameType 1.3.6.1.4.1.18.3.4.10.1.7
Frame Type - differentiates between two tarrifed framing formats D4 and ESF.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER d4(1), esf(2)  

wfT1LineBuildout 1.3.6.1.4.1.18.3.4.10.1.8
Line Buildout - Approximate length of cable
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..655  

wfT1B8ZSSupport 1.3.6.1.4.1.18.3.4.10.1.9
B8ZS Support - Enables or disables Binary 8 zeros suppression
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfT1ClockMode 1.3.6.1.4.1.18.3.4.10.1.10
Clock Mode - Specifies the source of the T1 transmit clock
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER internal(1), slave(2), manual(4)  

wfT1MiniDacs 1.3.6.1.4.1.18.3.4.10.1.11
MiniDacs Configuration - assigns each T1 channel to a specific function
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

wfT1BipolarVios 1.3.6.1.4.1.18.3.4.10.1.12
Number of Bipolar Violations
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfT1FrameBitErrs 1.3.6.1.4.1.18.3.4.10.1.13
Number of frame bit errors
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfT1OutOfFrameErrs 1.3.6.1.4.1.18.3.4.10.1.14
Number of Out of Frame errors
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfT1SuperFrameErrs 1.3.6.1.4.1.18.3.4.10.1.15
Number of Superframe errors
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfT1RcvYelAlarms 1.3.6.1.4.1.18.3.4.10.1.16
Number of Yellow Alarms Received
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfT1RcvCarrierLoss 1.3.6.1.4.1.18.3.4.10.1.17
Number of instances of carrier loss
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfT1RcvRedAlarms 1.3.6.1.4.1.18.3.4.10.1.18
Number of Red Alarm Received
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter