Webio-Digital-MIB-US

File: Webio-Digital-MIB-US.mib (1205659 bytes)

Imported modules

RFC-1212 RFC-1215 RFC1213-MIB
RFC1155-SMI

Imported symbols

OBJECT-TYPE TRAP-TYPE DisplayString
PhysAddress enterprises TimeTicks
IpAddress NetworkAddress

Defined Types

WtWebioEA2x2InputEntry  
SEQUENCE    
  wtWebioEA2x2InputNo INTEGER
  wtWebioEA2x2InputCounter INTEGER
  wtWebioEA2x2InputCounterClear INTEGER
  wtWebioEA2x2InputState INTEGER

WtWebioEA2x2OutputEntry  
SEQUENCE    
  wtWebioEA2x2OutputNo INTEGER
  wtWebioEA2x2OutputState INTEGER

WtWebioEA2x2BinaryIfEntry  
SEQUENCE    
  wtWebioEA2x2BinaryModeNo INTEGER

WtWebioEA2x2BinaryEntry  
SEQUENCE    
  wtWebioEA2x2BinaryOperationMode OCTET STRING
  wtWebioEA2x2BinaryTcpServerLocalPort INTEGER
  wtWebioEA2x2BinaryTcpServerInputTrigger OCTET STRING
  wtWebioEA2x2BinaryTcpServerApplicationMode OCTET STRING
  wtWebioEA2x2BinaryTcpClientLocalPort INTEGER
  wtWebioEA2x2BinaryTcpClientServerPort INTEGER
  wtWebioEA2x2BinaryTcpClientServerIpAddr OCTET STRING
  wtWebioEA2x2BinaryTcpClientServerPassword OCTET STRING
  wtWebioEA2x2BinaryTcpClientInactivity INTEGER
  wtWebioEA2x2BinaryTcpClientInputTrigger OCTET STRING
  wtWebioEA2x2BinaryTcpClientInterval INTEGER
  wtWebioEA2x2BinaryTcpClientApplicationMode OCTET STRING
  wtWebioEA2x2BinaryUdpPeerLocalPort INTEGER
  wtWebioEA2x2BinaryUdpPeerRemotePort INTEGER
  wtWebioEA2x2BinaryUdpPeerRemoteIpAddr OCTET STRING
  wtWebioEA2x2BinaryUdpPeerInputTrigger OCTET STRING
  wtWebioEA2x2BinaryUdpPeerInterval INTEGER
  wtWebioEA2x2BinaryUdpPeerApplicationMode OCTET STRING
  wtWebioEA2x2BinaryConnectedPort INTEGER
  wtWebioEA2x2BinaryConnectedIpAddr IpAddress
  wtWebioEA2x2BinaryTcpServerClientHttpPort INTEGER
  wtWebioEA2x2BinaryTcpClientServerHttpPort INTEGER

WtWebioEA2x2OutputModeEntry  
SEQUENCE    
  wtWebioEA2x2OutputModeBit OCTET STRING

WtWebioEA2x2AlarmIfEntry  
SEQUENCE    
  wtWebioEA2x2AlarmNo INTEGER

WtWebioEA2x2AlarmEntry  
SEQUENCE    
  wtWebioEA2x2AlarmInputTrigger OCTET STRING
  wtWebioEA2x2AlarmOutputTrigger OCTET STRING
  wtWebioEA2x2AlarmSystemTrigger OCTET STRING
  wtWebioEA2x2AlarmMaxCounterValue OCTET STRING
  wtWebioEA2x2AlarmInterval OCTET STRING
  wtWebioEA2x2AlarmEnable OCTET STRING
  wtWebioEA2x2AlarmMailAddr OCTET STRING
  wtWebioEA2x2AlarmMailSubject OCTET STRING
  wtWebioEA2x2AlarmMailText OCTET STRING
  wtWebioEA2x2AlarmSnmpManagerIP OCTET STRING
  wtWebioEA2x2AlarmSnmpTrapText OCTET STRING
  wtWebioEA2x2AlarmUdpIpAddr OCTET STRING
  wtWebioEA2x2AlarmUdpPort INTEGER
  wtWebioEA2x2AlarmUdpText OCTET STRING
  wtWebioEA2x2AlarmTcpIpAddr OCTET STRING
  wtWebioEA2x2AlarmTcpPort INTEGER
  wtWebioEA2x2AlarmTcpText OCTET STRING
  wtWebioEA2x2AlarmSyslogIpAddr OCTET STRING
  wtWebioEA2x2AlarmSyslogPort INTEGER
  wtWebioEA2x2AlarmSyslogText OCTET STRING
  wtWebioEA2x2AlarmFtpDataPort OCTET STRING
  wtWebioEA2x2AlarmFtpFileName OCTET STRING
  wtWebioEA2x2AlarmFtpText OCTET STRING
  wtWebioEA2x2AlarmFtpOption OCTET STRING
  wtWebioEA2x2AlarmTimerCron OCTET STRING
  wtWebioEA2x2AlarmMailReleaseSubject OCTET STRING
  wtWebioEA2x2AlarmMailReleaseText OCTET STRING
  wtWebioEA2x2AlarmSnmpTrapReleaseText OCTET STRING
  wtWebioEA2x2AlarmUdpReleaseText OCTET STRING
  wtWebioEA2x2AlarmTcpReleaseText OCTET STRING
  wtWebioEA2x2AlarmSyslogReleaseText OCTET STRING
  wtWebioEA2x2AlarmFtpReleaseText OCTET STRING

WtWebioEA2x2InputPortEntry  
SEQUENCE    
  wtWebioEA2x2PortInputName OCTET STRING
  wtWebioEA2x2PortInputText OCTET STRING
  wtWebioEA2x2PortInputMode OCTET STRING
  wtWebioEA2x2PortInputFilter INTEGER
  wtWebioEA2x2PortInputBicountPulsePolarity OCTET STRING
  wtWebioEA2x2PortInputBicountInactivTimeout INTEGER

WtWebioEA2x2OutputPortEntry  
SEQUENCE    
  wtWebioEA2x2PortOutputName OCTET STRING
  wtWebioEA2x2PortOutputText OCTET STRING
  wtWebioEA2x2PortOutputGroupMode OCTET STRING
  wtWebioEA2x2PortOutputSafetyState OCTET STRING
  wtWebioEA2x2PortLogicInputMask OCTET STRING
  wtWebioEA2x2PortLogicInputInverter OCTET STRING
  wtWebioEA2x2PortLogicFunction OCTET STRING
  wtWebioEA2x2PortLogicOutputInverter OCTET STRING
  wtWebioEA2x2PortPulseDuration INTEGER
  wtWebioEA2x2PortPulsePolarity OCTET STRING

WtWebioEA12x12InputEntry  
SEQUENCE    
  wtWebioEA12x12InputNo INTEGER
  wtWebioEA12x12InputCounter INTEGER
  wtWebioEA12x12InputCounterClear INTEGER
  wtWebioEA12x12InputState INTEGER

WtWebioEA12x12OutputEntry  
SEQUENCE    
  wtWebioEA12x12OutputNo INTEGER
  wtWebioEA12x12OutputState INTEGER

WtWebioEA12x12BinaryIfEntry  
SEQUENCE    
  wtWebioEA12x12BinaryModeNo INTEGER

WtWebioEA12x12BinaryEntry  
SEQUENCE    
  wtWebioEA12x12BinaryOperationMode OCTET STRING
  wtWebioEA12x12BinaryTcpServerLocalPort INTEGER
  wtWebioEA12x12BinaryTcpServerInputTrigger OCTET STRING
  wtWebioEA12x12BinaryTcpServerApplicationMode OCTET STRING
  wtWebioEA12x12BinaryTcpClientLocalPort INTEGER
  wtWebioEA12x12BinaryTcpClientServerPort INTEGER
  wtWebioEA12x12BinaryTcpClientServerIpAddr OCTET STRING
  wtWebioEA12x12BinaryTcpClientServerPassword OCTET STRING
  wtWebioEA12x12BinaryTcpClientInactivity INTEGER
  wtWebioEA12x12BinaryTcpClientInputTrigger OCTET STRING
  wtWebioEA12x12BinaryTcpClientInterval INTEGER
  wtWebioEA12x12BinaryTcpClientApplicationMode OCTET STRING
  wtWebioEA12x12BinaryUdpPeerLocalPort INTEGER
  wtWebioEA12x12BinaryUdpPeerRemotePort INTEGER
  wtWebioEA12x12BinaryUdpPeerRemoteIpAddr OCTET STRING
  wtWebioEA12x12BinaryUdpPeerInputTrigger OCTET STRING
  wtWebioEA12x12BinaryUdpPeerInterval INTEGER
  wtWebioEA12x12BinaryUdpPeerApplicationMode OCTET STRING
  wtWebioEA12x12BinaryConnectedPort INTEGER
  wtWebioEA12x12BinaryConnectedIpAddr IpAddress
  wtWebioEA12x12BinaryTcpServerClientHttpPort INTEGER
  wtWebioEA12x12BinaryTcpClientServerHttpPort INTEGER

WtWebioEA12x12OutputModeEntry  
SEQUENCE    
  wtWebioEA12x12OutputModeBit OCTET STRING

WtWebioEA12x12AlarmIfEntry  
SEQUENCE    
  wtWebioEA12x12AlarmNo INTEGER

WtWebioEA12x12AlarmEntry  
SEQUENCE    
  wtWebioEA12x12AlarmInputTrigger OCTET STRING
  wtWebioEA12x12AlarmOutputTrigger OCTET STRING
  wtWebioEA12x12AlarmSystemTrigger OCTET STRING
  wtWebioEA12x12AlarmMaxCounterValue OCTET STRING
  wtWebioEA12x12AlarmInterval OCTET STRING
  wtWebioEA12x12AlarmEnable OCTET STRING
  wtWebioEA12x12AlarmMailAddr OCTET STRING
  wtWebioEA12x12AlarmMailSubject OCTET STRING
  wtWebioEA12x12AlarmMailText OCTET STRING
  wtWebioEA12x12AlarmSnmpManagerIP OCTET STRING
  wtWebioEA12x12AlarmSnmpTrapText OCTET STRING
  wtWebioEA12x12AlarmUdpIpAddr OCTET STRING
  wtWebioEA12x12AlarmUdpPort INTEGER
  wtWebioEA12x12AlarmUdpText OCTET STRING
  wtWebioEA12x12AlarmTcpIpAddr OCTET STRING
  wtWebioEA12x12AlarmTcpPort INTEGER
  wtWebioEA12x12AlarmTcpText OCTET STRING
  wtWebioEA12x12AlarmSyslogIpAddr OCTET STRING
  wtWebioEA12x12AlarmSyslogPort INTEGER
  wtWebioEA12x12AlarmSyslogText OCTET STRING
  wtWebioEA12x12AlarmFtpDataPort OCTET STRING
  wtWebioEA12x12AlarmFtpFileName OCTET STRING
  wtWebioEA12x12AlarmFtpText OCTET STRING
  wtWebioEA12x12AlarmFtpOption OCTET STRING
  wtWebioEA12x12AlarmTimerCron OCTET STRING
  wtWebioEA12x12AlarmMailReleaseSubject OCTET STRING
  wtWebioEA12x12AlarmMailReleaseText OCTET STRING
  wtWebioEA12x12AlarmSnmpTrapReleaseText OCTET STRING
  wtWebioEA12x12AlarmUdpReleaseText OCTET STRING
  wtWebioEA12x12AlarmTcpReleaseText OCTET STRING
  wtWebioEA12x12AlarmSyslogReleaseText OCTET STRING
  wtWebioEA12x12AlarmFtpReleaseText OCTET STRING

WtWebioEA12x12InputPortEntry  
SEQUENCE    
  wtWebioEA12x12PortInputName OCTET STRING
  wtWebioEA12x12PortInputText OCTET STRING
  wtWebioEA12x12PortInputMode OCTET STRING
  wtWebioEA12x12PortInputFilter INTEGER
  wtWebioEA12x12PortInputBicountPulsePolarity OCTET STRING
  wtWebioEA12x12PortInputBicountInactivTimeout INTEGER

WtWebioEA12x12OutputPortEntry  
SEQUENCE    
  wtWebioEA12x12PortOutputName OCTET STRING
  wtWebioEA12x12PortOutputText OCTET STRING
  wtWebioEA12x12PortOutputGroupMode OCTET STRING
  wtWebioEA12x12PortOutputSafetyState OCTET STRING
  wtWebioEA12x12PortLogicInputMask OCTET STRING
  wtWebioEA12x12PortLogicInputInverter OCTET STRING
  wtWebioEA12x12PortLogicFunction OCTET STRING
  wtWebioEA12x12PortLogicOutputInverter OCTET STRING
  wtWebioEA12x12PortPulseDuration INTEGER
  wtWebioEA12x12PortPulsePolarity OCTET STRING

WtWebioEA24oemInputEntry  
SEQUENCE    
  wtWebioEA24oemInputNo INTEGER
  wtWebioEA24oemInputCounter INTEGER
  wtWebioEA24oemInputCounterClear INTEGER
  wtWebioEA24oemInputState INTEGER

WtWebioEA24oemOutputEntry  
SEQUENCE    
  wtWebioEA24oemOutputNo INTEGER
  wtWebioEA24oemOutputState INTEGER

WtWebioEA24oemBinaryIfEntry  
SEQUENCE    
  wtWebioEA24oemBinaryModeNo INTEGER

WtWebioEA24oemBinaryEntry  
SEQUENCE    
  wtWebioEA24oemBinaryOperationMode OCTET STRING
  wtWebioEA24oemBinaryTcpServerLocalPort INTEGER
  wtWebioEA24oemBinaryTcpServerInputTrigger OCTET STRING
  wtWebioEA24oemBinaryTcpServerApplicationMode OCTET STRING
  wtWebioEA24oemBinaryTcpClientLocalPort INTEGER
  wtWebioEA24oemBinaryTcpClientServerPort INTEGER
  wtWebioEA24oemBinaryTcpClientServerIpAddr OCTET STRING
  wtWebioEA24oemBinaryTcpClientServerPassword OCTET STRING
  wtWebioEA24oemBinaryTcpClientInactivity INTEGER
  wtWebioEA24oemBinaryTcpClientInputTrigger OCTET STRING
  wtWebioEA24oemBinaryTcpClientInterval INTEGER
  wtWebioEA24oemBinaryTcpClientApplicationMode OCTET STRING
  wtWebioEA24oemBinaryUdpPeerLocalPort INTEGER
  wtWebioEA24oemBinaryUdpPeerRemotePort INTEGER
  wtWebioEA24oemBinaryUdpPeerRemoteIpAddr OCTET STRING
  wtWebioEA24oemBinaryUdpPeerInputTrigger OCTET STRING
  wtWebioEA24oemBinaryUdpPeerInterval INTEGER
  wtWebioEA24oemBinaryUdpPeerApplicationMode OCTET STRING
  wtWebioEA24oemBinaryConnectedPort INTEGER
  wtWebioEA24oemBinaryConnectedIpAddr IpAddress
  wtWebioEA24oemBinaryTcpServerClientHttpPort INTEGER
  wtWebioEA24oemBinaryTcpClientServerHttpPort INTEGER

WtWebioEA24oemOutputModeEntry  
SEQUENCE    
  wtWebioEA24oemOutputModeBit OCTET STRING

WtWebioEA24oemAlarmIfEntry  
SEQUENCE    
  wtWebioEA24oemAlarmNo INTEGER

WtWebioEA24oemAlarmEntry  
SEQUENCE    
  wtWebioEA24oemAlarmInputTrigger OCTET STRING
  wtWebioEA24oemAlarmOutputTrigger OCTET STRING
  wtWebioEA24oemAlarmSystemTrigger OCTET STRING
  wtWebioEA24oemAlarmMaxCounterValue OCTET STRING
  wtWebioEA24oemAlarmInterval OCTET STRING
  wtWebioEA24oemAlarmEnable OCTET STRING
  wtWebioEA24oemAlarmMailAddr OCTET STRING
  wtWebioEA24oemAlarmMailSubject OCTET STRING
  wtWebioEA24oemAlarmMailText OCTET STRING
  wtWebioEA24oemAlarmSnmpManagerIP OCTET STRING
  wtWebioEA24oemAlarmSnmpTrapText OCTET STRING
  wtWebioEA24oemAlarmUdpIpAddr OCTET STRING
  wtWebioEA24oemAlarmUdpPort INTEGER
  wtWebioEA24oemAlarmUdpText OCTET STRING
  wtWebioEA24oemAlarmTcpIpAddr OCTET STRING
  wtWebioEA24oemAlarmTcpPort INTEGER
  wtWebioEA24oemAlarmTcpText OCTET STRING
  wtWebioEA24oemAlarmSyslogIpAddr OCTET STRING
  wtWebioEA24oemAlarmSyslogPort INTEGER
  wtWebioEA24oemAlarmSyslogText OCTET STRING
  wtWebioEA24oemAlarmFtpDataPort OCTET STRING
  wtWebioEA24oemAlarmFtpFileName OCTET STRING
  wtWebioEA24oemAlarmFtpText OCTET STRING
  wtWebioEA24oemAlarmFtpOption OCTET STRING
  wtWebioEA24oemAlarmTimerCron OCTET STRING

WtWebioEA24oemInputPortEntry  
SEQUENCE    
  wtWebioEA24oemPortInputName OCTET STRING
  wtWebioEA24oemPortInputText OCTET STRING
  wtWebioEA24oemPortInputMode OCTET STRING
  wtWebioEA24oemPortInputFilter INTEGER

WtWebioEA24oemOutputPortEntry  
SEQUENCE    
  wtWebioEA24oemPortOutputName OCTET STRING
  wtWebioEA24oemPortOutputText OCTET STRING
  wtWebioEA24oemPortOutputGroupMode OCTET STRING
  wtWebioEA24oemPortOutputSafetyState OCTET STRING
  wtWebioEA24oemPortLogicInputMask OCTET STRING
  wtWebioEA24oemPortLogicInputInverter OCTET STRING
  wtWebioEA24oemPortLogicFunction OCTET STRING
  wtWebioEA24oemPortLogicOutputInverter OCTET STRING
  wtWebioEA24oemPortPulseDuration INTEGER
  wtWebioEA24oemPortPulsePolarity OCTET STRING

WtWebioEA12x6RelInputEntry  
SEQUENCE    
  wtWebioEA12x6RelInputNo INTEGER
  wtWebioEA12x6RelInputCounter INTEGER
  wtWebioEA12x6RelInputCounterClear INTEGER

WtWebioEA12x6RelOutputEntry  
SEQUENCE    
  wtWebioEA12x6RelOutputNo INTEGER
  wtWebioEA12x6RelOutputState INTEGER

WtWebioEA12x6RelBinaryIfEntry  
SEQUENCE    
  wtWebioEA12x6RelBinaryModeNo INTEGER

WtWebioEA12x6RelBinaryEntry  
SEQUENCE    
  wtWebioEA12x6RelBinaryOperationMode OCTET STRING
  wtWebioEA12x6RelBinaryTcpServerLocalPort INTEGER
  wtWebioEA12x6RelBinaryTcpServerInputTrigger OCTET STRING
  wtWebioEA12x6RelBinaryTcpServerApplicationMode OCTET STRING
  wtWebioEA12x6RelBinaryTcpClientLocalPort INTEGER
  wtWebioEA12x6RelBinaryTcpClientServerPort INTEGER
  wtWebioEA12x6RelBinaryTcpClientServerIpAddr OCTET STRING
  wtWebioEA12x6RelBinaryTcpClientServerPassword OCTET STRING
  wtWebioEA12x6RelBinaryTcpClientInactivity INTEGER
  wtWebioEA12x6RelBinaryTcpClientInputTrigger OCTET STRING
  wtWebioEA12x6RelBinaryTcpClientInterval INTEGER
  wtWebioEA12x6RelBinaryTcpClientApplicationMode OCTET STRING
  wtWebioEA12x6RelBinaryUdpPeerLocalPort INTEGER
  wtWebioEA12x6RelBinaryUdpPeerRemotePort INTEGER
  wtWebioEA12x6RelBinaryUdpPeerRemoteIpAddr OCTET STRING
  wtWebioEA12x6RelBinaryUdpPeerInputTrigger OCTET STRING
  wtWebioEA12x6RelBinaryUdpPeerInterval INTEGER
  wtWebioEA12x6RelBinaryUdpPeerApplicationMode OCTET STRING
  wtWebioEA12x6RelBinaryConnectedPort INTEGER
  wtWebioEA12x6RelBinaryConnectedIpAddr IpAddress
  wtWebioEA12x6RelBinaryTcpServerClientHttpPort INTEGER
  wtWebioEA12x6RelBinaryTcpClientServerHttpPort INTEGER

WtWebioEA12x6RelOutputModeEntry  
SEQUENCE    
  wtWebioEA12x6RelOutputModeBit OCTET STRING

WtWebioEA12x6RelAlarmIfEntry  
SEQUENCE    
  wtWebioEA12x6RelAlarmNo INTEGER

WtWebioEA12x6RelAlarmEntry  
SEQUENCE    
  wtWebioEA12x6RelAlarmInputTrigger OCTET STRING
  wtWebioEA12x6RelAlarmOutputTrigger OCTET STRING
  wtWebioEA12x6RelAlarmSystemTrigger OCTET STRING
  wtWebioEA12x6RelAlarmMaxCounterValue OCTET STRING
  wtWebioEA12x6RelAlarmInterval OCTET STRING
  wtWebioEA12x6RelAlarmEnable OCTET STRING
  wtWebioEA12x6RelAlarmMailAddr OCTET STRING
  wtWebioEA12x6RelAlarmMailSubject OCTET STRING
  wtWebioEA12x6RelAlarmMailText OCTET STRING
  wtWebioEA12x6RelAlarmSnmpManagerIP OCTET STRING
  wtWebioEA12x6RelAlarmSnmpTrapText OCTET STRING
  wtWebioEA12x6RelAlarmUdpIpAddr OCTET STRING
  wtWebioEA12x6RelAlarmUdpPort INTEGER
  wtWebioEA12x6RelAlarmUdpText OCTET STRING
  wtWebioEA12x6RelAlarmTcpIpAddr OCTET STRING
  wtWebioEA12x6RelAlarmTcpPort INTEGER
  wtWebioEA12x6RelAlarmTcpText OCTET STRING
  wtWebioEA12x6RelAlarmSyslogIpAddr OCTET STRING
  wtWebioEA12x6RelAlarmSyslogPort INTEGER
  wtWebioEA12x6RelAlarmSyslogText OCTET STRING
  wtWebioEA12x6RelAlarmFtpDataPort OCTET STRING
  wtWebioEA12x6RelAlarmFtpFileName OCTET STRING
  wtWebioEA12x6RelAlarmFtpText OCTET STRING
  wtWebioEA12x6RelAlarmFtpOption OCTET STRING
  wtWebioEA12x6RelAlarmTimerCron OCTET STRING
  wtWebioEA12x6RelAlarmMailReleaseSubject OCTET STRING
  wtWebioEA12x6RelAlarmMailReleaseText OCTET STRING
  wtWebioEA12x6RelAlarmSnmpTrapReleaseText OCTET STRING
  wtWebioEA12x6RelAlarmUdpReleaseText OCTET STRING
  wtWebioEA12x6RelAlarmTcpReleaseText OCTET STRING
  wtWebioEA12x6RelAlarmSyslogReleaseText OCTET STRING
  wtWebioEA12x6RelAlarmFtpReleaseText OCTET STRING

WtWebioEA12x6RelInputPortEntry  
SEQUENCE    
  wtWebioEA12x6RelPortInputName OCTET STRING
  wtWebioEA12x6RelPortInputText OCTET STRING
  wtWebioEA12x6RelPortInputMode OCTET STRING
  wtWebioEA12x6RelPortInputFilter INTEGER
  wtWebioEA12x6RelPortInputBicountPulsePolarity OCTET STRING
  wtWebioEA12x6RelPortInputBicountInactivTimeout INTEGER

WtWebioEA12x6RelOutputPortEntry  
SEQUENCE    
  wtWebioEA12x6RelPortOutputName OCTET STRING
  wtWebioEA12x6RelPortOutputText OCTET STRING
  wtWebioEA12x6RelPortOutputGroupMode OCTET STRING
  wtWebioEA12x6RelPortOutputSafetyState OCTET STRING
  wtWebioEA12x6RelPortLogicInputMask OCTET STRING
  wtWebioEA12x6RelPortLogicInputInverter OCTET STRING
  wtWebioEA12x6RelPortLogicFunction OCTET STRING
  wtWebioEA12x6RelPortLogicOutputInverter OCTET STRING
  wtWebioEA12x6RelPortPulseDuration INTEGER
  wtWebioEA12x6RelPortPulsePolarity OCTET STRING

WtWebAlarm6x6InputEntry  
SEQUENCE    
  wtWebAlarm6x6InputNo INTEGER
  wtWebAlarm6x6InputCounter INTEGER
  wtWebAlarm6x6InputCounterClear INTEGER
  wtWebAlarm6x6InputState INTEGER

WtWebAlarm6x6OutputEntry  
SEQUENCE    
  wtWebAlarm6x6OutputNo INTEGER
  wtWebAlarm6x6OutputState INTEGER

WtWebAlarm6x6AlarmOutputEntry  
SEQUENCE    
  wtWebAlarm6x6AlarmOutputState INTEGER
  wtWebAlarm6x6AlarmTriggerState INTEGER

WtWebAlarm6x6AlarmIfEntry  
SEQUENCE    
  wtWebAlarm6x6AlarmNo INTEGER

WtWebAlarm6x6AlarmEntry  
SEQUENCE    
  wtWebAlarm6x6AlarmInputTrigger OCTET STRING
  wtWebAlarm6x6AlarmMaxCounterValue OCTET STRING
  wtWebAlarm6x6AlarmInterval OCTET STRING
  wtWebAlarm6x6AlarmEnable OCTET STRING
  wtWebAlarm6x6AlarmMailAddr OCTET STRING
  wtWebAlarm6x6AlarmMailSubject OCTET STRING
  wtWebAlarm6x6AlarmMailText OCTET STRING
  wtWebAlarm6x6AlarmSnmpManagerIP OCTET STRING
  wtWebAlarm6x6AlarmSnmpTrapText OCTET STRING
  wtWebAlarm6x6AlarmUdpIpAddr OCTET STRING
  wtWebAlarm6x6AlarmUdpPort INTEGER
  wtWebAlarm6x6AlarmUdpText OCTET STRING
  wtWebAlarm6x6AlarmTcpIpAddr OCTET STRING
  wtWebAlarm6x6AlarmTcpPort INTEGER
  wtWebAlarm6x6AlarmTcpText OCTET STRING
  wtWebAlarm6x6AlarmSyslogIpAddr OCTET STRING
  wtWebAlarm6x6AlarmSyslogPort INTEGER
  wtWebAlarm6x6AlarmSyslogText OCTET STRING
  wtWebAlarm6x6AlarmFtpDataPort OCTET STRING
  wtWebAlarm6x6AlarmFtpFileName OCTET STRING
  wtWebAlarm6x6AlarmFtpText OCTET STRING
  wtWebAlarm6x6AlarmFtpOption OCTET STRING
  wtWebAlarm6x6AlarmMailReleaseSubject OCTET STRING
  wtWebAlarm6x6AlarmMailReleaseText OCTET STRING
  wtWebAlarm6x6AlarmSnmpTrapReleaseText OCTET STRING
  wtWebAlarm6x6AlarmUdpReleaseText OCTET STRING
  wtWebAlarm6x6AlarmTcpReleaseText OCTET STRING
  wtWebAlarm6x6AlarmSyslogReleaseText OCTET STRING
  wtWebAlarm6x6AlarmFtpReleaseText OCTET STRING
  wtWebAlarm6x6AlarmName OCTET STRING
  wtWebAlarm6x6AlarmGlobalEnable OCTET STRING
  wtWebAlarm6x6AlarmCounterClear OCTET STRING
  wtWebAlarm6x6AlarmAckEnable OCTET STRING
  wtWebAlarm6x6AlarmAckPort INTEGER
  wtWebAlarm6x6AlarmSetPort INTEGER
  wtWebAlarm6x6AlarmMailTrgClearSubject OCTET STRING
  wtWebAlarm6x6AlarmMailTrgClearText OCTET STRING
  wtWebAlarm6x6AlarmSnmpTrapTrgClearText OCTET STRING
  wtWebAlarm6x6AlarmUdpTrgClearText OCTET STRING
  wtWebAlarm6x6AlarmTcpTrgClearText OCTET STRING
  wtWebAlarm6x6AlarmSyslogTrgClearText OCTET STRING
  wtWebAlarm6x6AlarmFtpTrgClearText OCTET STRING
  wtWebAlarm6x6AlarmMailTrapTxEnable OCTET STRING
  wtWebAlarm6x6AlarmSnmpTrapTrapTxEnable OCTET STRING
  wtWebAlarm6x6AlarmUdpTrapTxEnable OCTET STRING
  wtWebAlarm6x6AlarmTcpTrapTxEnable OCTET STRING
  wtWebAlarm6x6AlarmSyslogTrapTxEnable OCTET STRING
  wtWebAlarm6x6AlarmFtpTrapTxEnable OCTET STRING

WtWebAlarm6x6InputPortEntry  
SEQUENCE    
  wtWebAlarm6x6PortInputName OCTET STRING
  wtWebAlarm6x6PortInputText OCTET STRING
  wtWebAlarm6x6PortInputFilter INTEGER
  wtWebAlarm6x6PortInputPulsePolarity OCTET STRING
  wtWebAlarm6x6PortInputCounterSet INTEGER

WtWebAlarm6x6OutputPortEntry  
SEQUENCE    
  wtWebAlarm6x6PortOutputName OCTET STRING
  wtWebAlarm6x6PortOutputText OCTET STRING
  wtWebAlarm6x6PortPulseDuration INTEGER
  wtWebAlarm6x6PortPulsePolarity OCTET STRING

WtWebCount6InputEntry  
SEQUENCE    
  wtWebCount6InputNo INTEGER
  wtWebCount6InputCounter INTEGER
  wtWebCount6InputCounterClear INTEGER
  wtWebCount6InputState INTEGER

WtWebCount6ReportOutputEntry  
SEQUENCE    
  wtWebCount6ReportOutputState INTEGER
  wtWebCount6ReportTriggerState INTEGER

WtWebCount6ReportIfEntry  
SEQUENCE    
  wtWebCount6ReportNo INTEGER

WtWebCount6ReportEntry  
SEQUENCE    
  wtWebCount6ReportInputTrigger OCTET STRING
  wtWebCount6ReportSystemTrigger OCTET STRING
  wtWebCount6ReportMaxCounterValue OCTET STRING
  wtWebCount6ReportInterval OCTET STRING
  wtWebCount6ReportEnable OCTET STRING
  wtWebCount6ReportMailAddr OCTET STRING
  wtWebCount6ReportMailSubject OCTET STRING
  wtWebCount6ReportMailText OCTET STRING
  wtWebCount6ReportSnmpManagerIP OCTET STRING
  wtWebCount6ReportSnmpTrapText OCTET STRING
  wtWebCount6ReportUdpIpAddr OCTET STRING
  wtWebCount6ReportUdpPort INTEGER
  wtWebCount6ReportUdpText OCTET STRING
  wtWebCount6ReportTcpIpAddr OCTET STRING
  wtWebCount6ReportTcpPort INTEGER
  wtWebCount6ReportTcpText OCTET STRING
  wtWebCount6ReportSyslogIpAddr OCTET STRING
  wtWebCount6ReportSyslogPort INTEGER
  wtWebCount6ReportSyslogText OCTET STRING
  wtWebCount6ReportFtpDataPort OCTET STRING
  wtWebCount6ReportFtpFileName OCTET STRING
  wtWebCount6ReportFtpText OCTET STRING
  wtWebCount6ReportFtpOption OCTET STRING
  wtWebCount6ReportTimerCron OCTET STRING
  wtWebCount6ReportName OCTET STRING
  wtWebCount6ReportGlobalEnable OCTET STRING
  wtWebCount6ReportCounterClear OCTET STRING
  wtWebCount6ReportRateOfChange OCTET STRING
  wtWebCount6ReportRateOfChangeWindow OCTET STRING
  wtWebCount6ReportRateOfChange OCTET STRING
  wtWebCount6ReportRateOfChangeMode OCTET STRING

WtWebCount6InputPortEntry  
SEQUENCE    
  wtWebCount6PortInputName OCTET STRING
  wtWebCount6PortInputText OCTET STRING
  wtWebCount6PortInputMode OCTET STRING
  wtWebCount6PortInputFilter INTEGER
  wtWebCount6PortInputPulsePolarity OCTET STRING
  wtWebCount6PortInputBicountInactivTimeout INTEGER
  wtWebCount6PortInputCounterSet INTEGER
  wtWebCount6PortInputCounterScale OCTET STRING
  wtWebCount6PortInputCounterUnit OCTET STRING

WtWebioEA6x6InputEntry  
SEQUENCE    
  wtWebioEA6x6InputNo INTEGER
  wtWebioEA6x6InputCounter INTEGER
  wtWebioEA6x6InputCounterClear INTEGER
  wtWebioEA6x6InputState INTEGER

WtWebioEA6x6OutputEntry  
SEQUENCE    
  wtWebioEA6x6OutputNo INTEGER
  wtWebioEA6x6OutputState INTEGER

WtWebioEA6x6BinaryIfEntry  
SEQUENCE    
  wtWebioEA6x6BinaryModeNo INTEGER

WtWebioEA6x6BinaryEntry  
SEQUENCE    
  wtWebioEA6x6BinaryOperationMode OCTET STRING
  wtWebioEA6x6BinaryTcpServerLocalPort INTEGER
  wtWebioEA6x6BinaryTcpServerInputTrigger OCTET STRING
  wtWebioEA6x6BinaryTcpServerApplicationMode OCTET STRING
  wtWebioEA6x6BinaryTcpClientLocalPort INTEGER
  wtWebioEA6x6BinaryTcpClientServerPort INTEGER
  wtWebioEA6x6BinaryTcpClientServerIpAddr OCTET STRING
  wtWebioEA6x6BinaryTcpClientServerPassword OCTET STRING
  wtWebioEA6x6BinaryTcpClientInactivity INTEGER
  wtWebioEA6x6BinaryTcpClientInputTrigger OCTET STRING
  wtWebioEA6x6BinaryTcpClientInterval INTEGER
  wtWebioEA6x6BinaryTcpClientApplicationMode OCTET STRING
  wtWebioEA6x6BinaryUdpPeerLocalPort INTEGER
  wtWebioEA6x6BinaryUdpPeerRemotePort INTEGER
  wtWebioEA6x6BinaryUdpPeerRemoteIpAddr OCTET STRING
  wtWebioEA6x6BinaryUdpPeerInputTrigger OCTET STRING
  wtWebioEA6x6BinaryUdpPeerInterval INTEGER
  wtWebioEA6x6BinaryUdpPeerApplicationMode OCTET STRING
  wtWebioEA6x6BinaryConnectedPort INTEGER
  wtWebioEA6x6BinaryConnectedIpAddr IpAddress
  wtWebioEA6x6BinaryTcpServerClientHttpPort INTEGER
  wtWebioEA6x6BinaryTcpClientServerHttpPort INTEGER

WtWebioEA6x6OutputModeEntry  
SEQUENCE    
  wtWebioEA6x6OutputModeBit OCTET STRING

WtWebioEA6x6AlarmIfEntry  
SEQUENCE    
  wtWebioEA6x6AlarmNo INTEGER

WtWebioEA6x6AlarmEntry  
SEQUENCE    
  wtWebioEA6x6AlarmInputTrigger OCTET STRING
  wtWebioEA6x6AlarmOutputTrigger OCTET STRING
  wtWebioEA6x6AlarmSystemTrigger OCTET STRING
  wtWebioEA6x6AlarmMaxCounterValue OCTET STRING
  wtWebioEA6x6AlarmInterval OCTET STRING
  wtWebioEA6x6AlarmEnable OCTET STRING
  wtWebioEA6x6AlarmMailAddr OCTET STRING
  wtWebioEA6x6AlarmMailSubject OCTET STRING
  wtWebioEA6x6AlarmMailText OCTET STRING
  wtWebioEA6x6AlarmSnmpManagerIP OCTET STRING
  wtWebioEA6x6AlarmSnmpTrapText OCTET STRING
  wtWebioEA6x6AlarmUdpIpAddr OCTET STRING
  wtWebioEA6x6AlarmUdpPort INTEGER
  wtWebioEA6x6AlarmUdpText OCTET STRING
  wtWebioEA6x6AlarmTcpIpAddr OCTET STRING
  wtWebioEA6x6AlarmTcpPort INTEGER
  wtWebioEA6x6AlarmTcpText OCTET STRING
  wtWebioEA6x6AlarmSyslogIpAddr OCTET STRING
  wtWebioEA6x6AlarmSyslogPort INTEGER
  wtWebioEA6x6AlarmSyslogText OCTET STRING
  wtWebioEA6x6AlarmFtpDataPort OCTET STRING
  wtWebioEA6x6AlarmFtpFileName OCTET STRING
  wtWebioEA6x6AlarmFtpText OCTET STRING
  wtWebioEA6x6AlarmFtpOption OCTET STRING
  wtWebioEA6x6AlarmTimerCron OCTET STRING
  wtWebioEA6x6AlarmMailReleaseSubject OCTET STRING
  wtWebioEA6x6AlarmMailReleaseText OCTET STRING
  wtWebioEA6x6AlarmSnmpTrapReleaseText OCTET STRING
  wtWebioEA6x6AlarmUdpReleaseText OCTET STRING
  wtWebioEA6x6AlarmTcpReleaseText OCTET STRING
  wtWebioEA6x6AlarmSyslogReleaseText OCTET STRING
  wtWebioEA6x6AlarmFtpReleaseText OCTET STRING

WtWebioEA6x6InputPortEntry  
SEQUENCE    
  wtWebioEA6x6PortInputName OCTET STRING
  wtWebioEA6x6PortInputText OCTET STRING
  wtWebioEA6x6PortInputMode OCTET STRING
  wtWebioEA6x6PortInputFilter INTEGER
  wtWebioEA6x6PortInputBicountPulsePolarity OCTET STRING
  wtWebioEA6x6PortInputBicountInactivTimeout INTEGER

WtWebioEA6x6OutputPortEntry  
SEQUENCE    
  wtWebioEA6x6PortOutputName OCTET STRING
  wtWebioEA6x6PortOutputText OCTET STRING
  wtWebioEA6x6PortOutputGroupMode OCTET STRING
  wtWebioEA6x6PortOutputSafetyState OCTET STRING
  wtWebioEA6x6PortLogicInputMask OCTET STRING
  wtWebioEA6x6PortLogicInputInverter OCTET STRING
  wtWebioEA6x6PortLogicFunction OCTET STRING
  wtWebioEA6x6PortLogicOutputInverter OCTET STRING
  wtWebioEA6x6PortPulseDuration INTEGER
  wtWebioEA6x6PortPulsePolarity OCTET STRING

WtWebioEA2x2ERPInputEntry  
SEQUENCE    
  wtWebioEA2x2ERPInputNo INTEGER
  wtWebioEA2x2ERPInputCounter INTEGER
  wtWebioEA2x2ERPInputCounterClear INTEGER
  wtWebioEA2x2ERPInputState INTEGER

WtWebioEA2x2ERPOutputEntry  
SEQUENCE    
  wtWebioEA2x2ERPOutputNo INTEGER
  wtWebioEA2x2ERPOutputState INTEGER

WtWebioEA2x2ERPBinaryIfEntry  
SEQUENCE    
  wtWebioEA2x2ERPBinaryModeNo INTEGER

WtWebioEA2x2ERPBinaryEntry  
SEQUENCE    
  wtWebioEA2x2ERPBinaryOperationMode OCTET STRING
  wtWebioEA2x2ERPBinaryTcpServerLocalPort INTEGER
  wtWebioEA2x2ERPBinaryTcpServerInputTrigger OCTET STRING
  wtWebioEA2x2ERPBinaryTcpServerApplicationMode OCTET STRING
  wtWebioEA2x2ERPBinaryTcpClientLocalPort INTEGER
  wtWebioEA2x2ERPBinaryTcpClientServerPort INTEGER
  wtWebioEA2x2ERPBinaryTcpClientServerIpAddr OCTET STRING
  wtWebioEA2x2ERPBinaryTcpClientServerPassword OCTET STRING
  wtWebioEA2x2ERPBinaryTcpClientInactivity INTEGER
  wtWebioEA2x2ERPBinaryTcpClientInputTrigger OCTET STRING
  wtWebioEA2x2ERPBinaryTcpClientInterval INTEGER
  wtWebioEA2x2ERPBinaryTcpClientApplicationMode OCTET STRING
  wtWebioEA2x2ERPBinaryUdpPeerLocalPort INTEGER
  wtWebioEA2x2ERPBinaryUdpPeerRemotePort INTEGER
  wtWebioEA2x2ERPBinaryUdpPeerRemoteIpAddr OCTET STRING
  wtWebioEA2x2ERPBinaryUdpPeerInputTrigger OCTET STRING
  wtWebioEA2x2ERPBinaryUdpPeerInterval INTEGER
  wtWebioEA2x2ERPBinaryUdpPeerApplicationMode OCTET STRING
  wtWebioEA2x2ERPBinaryConnectedPort INTEGER
  wtWebioEA2x2ERPBinaryConnectedIpAddr IpAddress
  wtWebioEA2x2ERPBinaryTcpServerClientHttpPort INTEGER
  wtWebioEA2x2ERPBinaryTcpClientServerHttpPort INTEGER

WtWebioEA2x2ERPOutputModeEntry  
SEQUENCE    
  wtWebioEA2x2ERPOutputModeBit OCTET STRING

WtWebioEA2x2ERPAlarmIfEntry  
SEQUENCE    
  wtWebioEA2x2ERPAlarmNo INTEGER

WtWebioEA2x2ERPAlarmEntry  
SEQUENCE    
  wtWebioEA2x2ERPAlarmInputTrigger OCTET STRING
  wtWebioEA2x2ERPAlarmOutputTrigger OCTET STRING
  wtWebioEA2x2ERPAlarmSystemTrigger OCTET STRING
  wtWebioEA2x2ERPAlarmMaxCounterValue OCTET STRING
  wtWebioEA2x2ERPAlarmInterval OCTET STRING
  wtWebioEA2x2ERPAlarmEnable OCTET STRING
  wtWebioEA2x2ERPAlarmMailAddr OCTET STRING
  wtWebioEA2x2ERPAlarmMailSubject OCTET STRING
  wtWebioEA2x2ERPAlarmMailText OCTET STRING
  wtWebioEA2x2ERPAlarmSnmpManagerIP OCTET STRING
  wtWebioEA2x2ERPAlarmSnmpTrapText OCTET STRING
  wtWebioEA2x2ERPAlarmUdpIpAddr OCTET STRING
  wtWebioEA2x2ERPAlarmUdpPort INTEGER
  wtWebioEA2x2ERPAlarmUdpText OCTET STRING
  wtWebioEA2x2ERPAlarmTcpIpAddr OCTET STRING
  wtWebioEA2x2ERPAlarmTcpPort INTEGER
  wtWebioEA2x2ERPAlarmTcpText OCTET STRING
  wtWebioEA2x2ERPAlarmSyslogIpAddr OCTET STRING
  wtWebioEA2x2ERPAlarmSyslogPort INTEGER
  wtWebioEA2x2ERPAlarmSyslogText OCTET STRING
  wtWebioEA2x2ERPAlarmFtpDataPort OCTET STRING
  wtWebioEA2x2ERPAlarmFtpFileName OCTET STRING
  wtWebioEA2x2ERPAlarmFtpText OCTET STRING
  wtWebioEA2x2ERPAlarmFtpOption OCTET STRING
  wtWebioEA2x2ERPAlarmTimerCron OCTET STRING
  wtWebioEA2x2ERPAlarmMailReleaseSubject OCTET STRING
  wtWebioEA2x2ERPAlarmMailReleaseText OCTET STRING
  wtWebioEA2x2ERPAlarmSnmpTrapReleaseText OCTET STRING
  wtWebioEA2x2ERPAlarmUdpReleaseText OCTET STRING
  wtWebioEA2x2ERPAlarmTcpReleaseText OCTET STRING
  wtWebioEA2x2ERPAlarmSyslogReleaseText OCTET STRING
  wtWebioEA2x2ERPAlarmFtpReleaseText OCTET STRING

WtWebioEA2x2ERPInputPortEntry  
SEQUENCE    
  wtWebioEA2x2ERPPortInputName OCTET STRING
  wtWebioEA2x2ERPPortInputText OCTET STRING
  wtWebioEA2x2ERPPortInputMode OCTET STRING
  wtWebioEA2x2ERPPortInputFilter INTEGER
  wtWebioEA2x2ERPPortInputBicountPulsePolarity OCTET STRING
  wtWebioEA2x2ERPPortInputBicountInactivTimeout INTEGER

WtWebioEA2x2ERPOutputPortEntry  
SEQUENCE    
  wtWebioEA2x2ERPPortOutputName OCTET STRING
  wtWebioEA2x2ERPPortOutputText OCTET STRING
  wtWebioEA2x2ERPPortOutputGroupMode OCTET STRING
  wtWebioEA2x2ERPPortOutputSafetyState OCTET STRING
  wtWebioEA2x2ERPPortLogicInputMask OCTET STRING
  wtWebioEA2x2ERPPortLogicInputInverter OCTET STRING
  wtWebioEA2x2ERPPortLogicFunction OCTET STRING
  wtWebioEA2x2ERPPortLogicOutputInverter OCTET STRING
  wtWebioEA2x2ERPPortPulseDuration INTEGER
  wtWebioEA2x2ERPPortPulsePolarity OCTET STRING

WtWebioEA12x6RelERPInputEntry  
SEQUENCE    
  wtWebioEA12x6RelERPInputNo INTEGER
  wtWebioEA12x6RelERPInputCounter INTEGER
  wtWebioEA12x6RelERPInputCounterClear INTEGER

WtWebioEA12x6RelERPOutputEntry  
SEQUENCE    
  wtWebioEA12x6RelERPOutputNo INTEGER
  wtWebioEA12x6RelERPOutputState INTEGER

WtWebioEA12x6RelERPBinaryIfEntry  
SEQUENCE    
  wtWebioEA12x6RelERPBinaryModeNo INTEGER

WtWebioEA12x6RelERPBinaryEntry  
SEQUENCE    
  wtWebioEA12x6RelERPBinaryOperationMode OCTET STRING
  wtWebioEA12x6RelERPBinaryTcpServerLocalPort INTEGER
  wtWebioEA12x6RelERPBinaryTcpServerInputTrigger OCTET STRING
  wtWebioEA12x6RelERPBinaryTcpServerApplicationMode OCTET STRING
  wtWebioEA12x6RelERPBinaryTcpClientLocalPort INTEGER
  wtWebioEA12x6RelERPBinaryTcpClientServerPort INTEGER
  wtWebioEA12x6RelERPBinaryTcpClientServerIpAddr OCTET STRING
  wtWebioEA12x6RelERPBinaryTcpClientServerPassword OCTET STRING
  wtWebioEA12x6RelERPBinaryTcpClientInactivity INTEGER
  wtWebioEA12x6RelERPBinaryTcpClientInputTrigger OCTET STRING
  wtWebioEA12x6RelERPBinaryTcpClientInterval INTEGER
  wtWebioEA12x6RelERPBinaryTcpClientApplicationMode OCTET STRING
  wtWebioEA12x6RelERPBinaryUdpPeerLocalPort INTEGER
  wtWebioEA12x6RelERPBinaryUdpPeerRemotePort INTEGER
  wtWebioEA12x6RelERPBinaryUdpPeerRemoteIpAddr OCTET STRING
  wtWebioEA12x6RelERPBinaryUdpPeerInputTrigger OCTET STRING
  wtWebioEA12x6RelERPBinaryUdpPeerInterval INTEGER
  wtWebioEA12x6RelERPBinaryUdpPeerApplicationMode OCTET STRING
  wtWebioEA12x6RelERPBinaryConnectedPort INTEGER
  wtWebioEA12x6RelERPBinaryConnectedIpAddr IpAddress
  wtWebioEA12x6RelERPBinaryTcpServerClientHttpPort INTEGER
  wtWebioEA12x6RelERPBinaryTcpClientServerHttpPort INTEGER

WtWebioEA12x6RelERPOutputModeEntry  
SEQUENCE    
  wtWebioEA12x6RelERPOutputModeBit OCTET STRING

WtWebioEA12x6RelERPAlarmIfEntry  
SEQUENCE    
  wtWebioEA12x6RelERPAlarmNo INTEGER

WtWebioEA12x6RelERPAlarmEntry  
SEQUENCE    
  wtWebioEA12x6RelERPAlarmInputTrigger OCTET STRING
  wtWebioEA12x6RelERPAlarmOutputTrigger OCTET STRING
  wtWebioEA12x6RelERPAlarmSystemTrigger OCTET STRING
  wtWebioEA12x6RelERPAlarmMaxCounterValue OCTET STRING
  wtWebioEA12x6RelERPAlarmInterval OCTET STRING
  wtWebioEA12x6RelERPAlarmEnable OCTET STRING
  wtWebioEA12x6RelERPAlarmMailAddr OCTET STRING
  wtWebioEA12x6RelERPAlarmMailSubject OCTET STRING
  wtWebioEA12x6RelERPAlarmMailText OCTET STRING
  wtWebioEA12x6RelERPAlarmSnmpManagerIP OCTET STRING
  wtWebioEA12x6RelERPAlarmSnmpTrapText OCTET STRING
  wtWebioEA12x6RelERPAlarmUdpIpAddr OCTET STRING
  wtWebioEA12x6RelERPAlarmUdpPort INTEGER
  wtWebioEA12x6RelERPAlarmUdpText OCTET STRING
  wtWebioEA12x6RelERPAlarmTcpIpAddr OCTET STRING
  wtWebioEA12x6RelERPAlarmTcpPort INTEGER
  wtWebioEA12x6RelERPAlarmTcpText OCTET STRING
  wtWebioEA12x6RelERPAlarmSyslogIpAddr OCTET STRING
  wtWebioEA12x6RelERPAlarmSyslogPort INTEGER
  wtWebioEA12x6RelERPAlarmSyslogText OCTET STRING
  wtWebioEA12x6RelERPAlarmFtpDataPort OCTET STRING
  wtWebioEA12x6RelERPAlarmFtpFileName OCTET STRING
  wtWebioEA12x6RelERPAlarmFtpText OCTET STRING
  wtWebioEA12x6RelERPAlarmFtpOption OCTET STRING
  wtWebioEA12x6RelERPAlarmTimerCron OCTET STRING
  wtWebioEA12x6RelERPAlarmMailReleaseSubject OCTET STRING
  wtWebioEA12x6RelERPAlarmMailReleaseText OCTET STRING
  wtWebioEA12x6RelERPAlarmSnmpTrapReleaseText OCTET STRING
  wtWebioEA12x6RelERPAlarmUdpReleaseText OCTET STRING
  wtWebioEA12x6RelERPAlarmTcpReleaseText OCTET STRING
  wtWebioEA12x6RelERPAlarmSyslogReleaseText OCTET STRING
  wtWebioEA12x6RelERPAlarmFtpReleaseText OCTET STRING

WtWebioEA12x6RelERPInputPortEntry  
SEQUENCE    
  wtWebioEA12x6RelERPPortInputName OCTET STRING
  wtWebioEA12x6RelERPPortInputText OCTET STRING
  wtWebioEA12x6RelERPPortInputMode OCTET STRING
  wtWebioEA12x6RelERPPortInputFilter INTEGER
  wtWebioEA12x6RelERPPortInputBicountPulsePolarity OCTET STRING
  wtWebioEA12x6RelERPPortInputBicountInactivTimeout INTEGER

WtWebioEA12x6RelERPOutputPortEntry  
SEQUENCE    
  wtWebioEA12x6RelERPPortOutputName OCTET STRING
  wtWebioEA12x6RelERPPortOutputText OCTET STRING
  wtWebioEA12x6RelERPPortOutputGroupMode OCTET STRING
  wtWebioEA12x6RelERPPortOutputSafetyState OCTET STRING
  wtWebioEA12x6RelERPPortLogicInputMask OCTET STRING
  wtWebioEA12x6RelERPPortLogicInputInverter OCTET STRING
  wtWebioEA12x6RelERPPortLogicFunction OCTET STRING
  wtWebioEA12x6RelERPPortLogicOutputInverter OCTET STRING
  wtWebioEA12x6RelERPPortPulseDuration INTEGER
  wtWebioEA12x6RelERPPortPulsePolarity OCTET STRING

WtIpWatcherInputEntry  
SEQUENCE    
  wtIpWatcherInputNo INTEGER
  wtIpWatcherInputCounter INTEGER
  wtIpWatcherInputCounterClear INTEGER
  wtIpWatcherInputState INTEGER

WtIpWatcherOutputEntry  
SEQUENCE    
  wtIpWatcherOutputNo INTEGER
  wtIpWatcherOutputState INTEGER

WtIpWatcherAlarmOutputEntry  
SEQUENCE    
  wtIpWatcherAlarmOutputState INTEGER
  wtIpWatcherAlarmTriggerState INTEGER

WtIpWatcherIpListIfEntry  
SEQUENCE    
  wtIpWatcherIpListNo INTEGER

WtIpWatcherIpListEntry  
SEQUENCE    
  wtIpWatcherIpListName OCTET STRING
  wtIpWatcherIpListPort INTEGER
  wtIpWatcherIpListService OCTET STRING
  wtIpWatcherIpListEnable OCTET STRING
  wtIpWatcherIpListAlias OCTET STRING

WtIpWatcherAlarmIfEntry  
SEQUENCE    
  wtIpWatcherAlarmNo INTEGER

WtIpWatcherAlarmEntry  
SEQUENCE    
  wtIpWatcherAlarmInterval OCTET STRING
  wtIpWatcherAlarmEnable OCTET STRING
  wtIpWatcherAlarmMailAddr OCTET STRING
  wtIpWatcherAlarmMailSubject OCTET STRING
  wtIpWatcherAlarmMailText OCTET STRING
  wtIpWatcherAlarmSnmpManagerIP OCTET STRING
  wtIpWatcherAlarmSnmpTrapText OCTET STRING
  wtIpWatcherAlarmUdpIpAddr OCTET STRING
  wtIpWatcherAlarmUdpPort INTEGER
  wtIpWatcherAlarmUdpText OCTET STRING
  wtIpWatcherAlarmTcpIpAddr OCTET STRING
  wtIpWatcherAlarmTcpPort INTEGER
  wtIpWatcherAlarmTcpText OCTET STRING
  wtIpWatcherAlarmSyslogIpAddr OCTET STRING
  wtIpWatcherAlarmSyslogPort INTEGER
  wtIpWatcherAlarmSyslogText OCTET STRING
  wtIpWatcherAlarmFtpDataPort OCTET STRING
  wtIpWatcherAlarmFtpFileName OCTET STRING
  wtIpWatcherAlarmFtpText OCTET STRING
  wtIpWatcherAlarmFtpOption OCTET STRING
  wtIpWatcherAlarmTimerCron OCTET STRING
  wtIpWatcherAlarmMailReleaseSubject OCTET STRING
  wtIpWatcherAlarmMailReleaseText OCTET STRING
  wtIpWatcherAlarmSnmpTrapReleaseText OCTET STRING
  wtIpWatcherAlarmUdpReleaseText OCTET STRING
  wtIpWatcherAlarmTcpReleaseText OCTET STRING
  wtIpWatcherAlarmSyslogReleaseText OCTET STRING
  wtIpWatcherAlarmFtpReleaseText OCTET STRING
  wtIpWatcherAlarmName OCTET STRING
  wtIpWatcherAlarmGlobalEnable OCTET STRING
  wtIpWatcherAlarmCounterClear OCTET STRING
  wtIpWatcherAlarmAckEnable OCTET STRING
  wtIpWatcherAlarmAckPort INTEGER
  wtIpWatcherAlarmSetPort INTEGER
  wtIpWatcherAlarmMailTrgClearSubject OCTET STRING
  wtIpWatcherAlarmMailTrgClearText OCTET STRING
  wtIpWatcherAlarmSnmpTrapTrgClearText OCTET STRING
  wtIpWatcherAlarmUdpTrgClearText OCTET STRING
  wtIpWatcherAlarmTcpTrgClearText OCTET STRING
  wtIpWatcherAlarmSyslogTrgClearText OCTET STRING
  wtIpWatcherAlarmFtpTrgClearText OCTET STRING
  wtIpWatcherAlarmMailTrapTxEnable OCTET STRING
  wtIpWatcherAlarmSnmpTrapTrapTxEnable OCTET STRING
  wtIpWatcherAlarmUdpTrapTxEnable OCTET STRING
  wtIpWatcherAlarmTcpTrapTxEnable OCTET STRING
  wtIpWatcherAlarmSyslogTrapTxEnable OCTET STRING
  wtIpWatcherAlarmFtpTrapTxEnable OCTET STRING
  wtIpWatcherAlarmTriggerCount INTEGER
  wtIpWatcherAlarmPollingRate INTEGER

WtIpWatcherInputPortEntry  
SEQUENCE    
  wtIpWatcherPortInputName OCTET STRING
  wtIpWatcherPortInputText OCTET STRING
  wtIpWatcherPortInputFilter INTEGER

WtIpWatcherOutputPortEntry  
SEQUENCE    
  wtIpWatcherPortOutputName OCTET STRING
  wtIpWatcherPortOutputText OCTET STRING
  wtIpWatcherPortPulseDuration INTEGER
  wtIpWatcherPortPulsePolarity OCTET STRING

WtWebioEA2x2-24VInputEntry  
SEQUENCE    
  wtWebioEA2x2-24VInputNo INTEGER
  wtWebioEA2x2-24VInputCounter INTEGER
  wtWebioEA2x2-24VInputCounterClear INTEGER
  wtWebioEA2x2-24VInputState INTEGER

WtWebioEA2x2-24VOutputEntry  
SEQUENCE    
  wtWebioEA2x2-24VOutputNo INTEGER
  wtWebioEA2x2-24VOutputState INTEGER

WtWebioEA2x2-24VBinaryIfEntry  
SEQUENCE    
  wtWebioEA2x2-24VBinaryModeNo INTEGER

WtWebioEA2x2-24VBinaryEntry  
SEQUENCE    
  wtWebioEA2x2-24VBinaryOperationMode OCTET STRING
  wtWebioEA2x2-24VBinaryTcpServerLocalPort INTEGER
  wtWebioEA2x2-24VBinaryTcpServerInputTrigger OCTET STRING
  wtWebioEA2x2-24VBinaryTcpServerApplicationMode OCTET STRING
  wtWebioEA2x2-24VBinaryTcpClientLocalPort INTEGER
  wtWebioEA2x2-24VBinaryTcpClientServerPort INTEGER
  wtWebioEA2x2-24VBinaryTcpClientServerIpAddr OCTET STRING
  wtWebioEA2x2-24VBinaryTcpClientServerPassword OCTET STRING
  wtWebioEA2x2-24VBinaryTcpClientInactivity INTEGER
  wtWebioEA2x2-24VBinaryTcpClientInputTrigger OCTET STRING
  wtWebioEA2x2-24VBinaryTcpClientInterval INTEGER
  wtWebioEA2x2-24VBinaryTcpClientApplicationMode OCTET STRING
  wtWebioEA2x2-24VBinaryUdpPeerLocalPort INTEGER
  wtWebioEA2x2-24VBinaryUdpPeerRemotePort INTEGER
  wtWebioEA2x2-24VBinaryUdpPeerRemoteIpAddr OCTET STRING
  wtWebioEA2x2-24VBinaryUdpPeerInputTrigger OCTET STRING
  wtWebioEA2x2-24VBinaryUdpPeerInterval INTEGER
  wtWebioEA2x2-24VBinaryUdpPeerApplicationMode OCTET STRING
  wtWebioEA2x2-24VBinaryConnectedPort INTEGER
  wtWebioEA2x2-24VBinaryConnectedIpAddr IpAddress
  wtWebioEA2x2-24VBinaryTcpServerClientHttpPort INTEGER
  wtWebioEA2x2-24VBinaryTcpClientServerHttpPort INTEGER

WtWebioEA2x2-24VOutputModeEntry  
SEQUENCE    
  wtWebioEA2x2-24VOutputModeBit OCTET STRING

WtWebioEA2x2-24VAlarmIfEntry  
SEQUENCE    
  wtWebioEA2x2-24VAlarmNo INTEGER

WtWebioEA2x2-24VAlarmEntry  
SEQUENCE    
  wtWebioEA2x2-24VAlarmInputTrigger OCTET STRING
  wtWebioEA2x2-24VAlarmOutputTrigger OCTET STRING
  wtWebioEA2x2-24VAlarmSystemTrigger OCTET STRING
  wtWebioEA2x2-24VAlarmMaxCounterValue OCTET STRING
  wtWebioEA2x2-24VAlarmInterval OCTET STRING
  wtWebioEA2x2-24VAlarmEnable OCTET STRING
  wtWebioEA2x2-24VAlarmMailAddr OCTET STRING
  wtWebioEA2x2-24VAlarmMailSubject OCTET STRING
  wtWebioEA2x2-24VAlarmMailText OCTET STRING
  wtWebioEA2x2-24VAlarmSnmpManagerIP OCTET STRING
  wtWebioEA2x2-24VAlarmSnmpTrapText OCTET STRING
  wtWebioEA2x2-24VAlarmUdpIpAddr OCTET STRING
  wtWebioEA2x2-24VAlarmUdpPort INTEGER
  wtWebioEA2x2-24VAlarmUdpText OCTET STRING
  wtWebioEA2x2-24VAlarmTcpIpAddr OCTET STRING
  wtWebioEA2x2-24VAlarmTcpPort INTEGER
  wtWebioEA2x2-24VAlarmTcpText OCTET STRING
  wtWebioEA2x2-24VAlarmSyslogIpAddr OCTET STRING
  wtWebioEA2x2-24VAlarmSyslogPort INTEGER
  wtWebioEA2x2-24VAlarmSyslogText OCTET STRING
  wtWebioEA2x2-24VAlarmFtpDataPort OCTET STRING
  wtWebioEA2x2-24VAlarmFtpFileName OCTET STRING
  wtWebioEA2x2-24VAlarmFtpText OCTET STRING
  wtWebioEA2x2-24VAlarmFtpOption OCTET STRING
  wtWebioEA2x2-24VAlarmTimerCron OCTET STRING
  wtWebioEA2x2-24VAlarmMailReleaseSubject OCTET STRING
  wtWebioEA2x2-24VAlarmMailReleaseText OCTET STRING
  wtWebioEA2x2-24VAlarmSnmpTrapReleaseText OCTET STRING
  wtWebioEA2x2-24VAlarmUdpReleaseText OCTET STRING
  wtWebioEA2x2-24VAlarmTcpReleaseText OCTET STRING
  wtWebioEA2x2-24VAlarmSyslogReleaseText OCTET STRING
  wtWebioEA2x2-24VAlarmFtpReleaseText OCTET STRING

WtWebioEA2x2-24VInputPortEntry  
SEQUENCE    
  wtWebioEA2x2-24VPortInputName OCTET STRING
  wtWebioEA2x2-24VPortInputText OCTET STRING
  wtWebioEA2x2-24VPortInputMode OCTET STRING
  wtWebioEA2x2-24VPortInputFilter INTEGER
  wtWebioEA2x2-24VPortInputBicountPulsePolarity OCTET STRING
  wtWebioEA2x2-24VPortInputBicountInactivTimeout INTEGER

WtWebioEA2x2-24VOutputPortEntry  
SEQUENCE    
  wtWebioEA2x2-24VPortOutputName OCTET STRING
  wtWebioEA2x2-24VPortOutputText OCTET STRING
  wtWebioEA2x2-24VPortOutputGroupMode OCTET STRING
  wtWebioEA2x2-24VPortOutputSafetyState OCTET STRING
  wtWebioEA2x2-24VPortLogicInputMask OCTET STRING
  wtWebioEA2x2-24VPortLogicInputInverter OCTET STRING
  wtWebioEA2x2-24VPortLogicFunction OCTET STRING
  wtWebioEA2x2-24VPortLogicOutputInverter OCTET STRING
  wtWebioEA2x2-24VPortPulseDuration INTEGER
  wtWebioEA2x2-24VPortPulsePolarity OCTET STRING

WtWebioEA2x2ERP-24VInputEntry  
SEQUENCE    
  wtWebioEA2x2ERP-24VInputNo INTEGER
  wtWebioEA2x2ERP-24VInputCounter INTEGER
  wtWebioEA2x2ERP-24VInputCounterClear INTEGER
  wtWebioEA2x2ERP-24VInputState INTEGER

WtWebioEA2x2ERP-24VOutputEntry  
SEQUENCE    
  wtWebioEA2x2ERP-24VOutputNo INTEGER
  wtWebioEA2x2ERP-24VOutputState INTEGER

WtWebioEA2x2ERP-24VBinaryIfEntry  
SEQUENCE    
  wtWebioEA2x2ERP-24VBinaryModeNo INTEGER

WtWebioEA2x2ERP-24VBinaryEntry  
SEQUENCE    
  wtWebioEA2x2ERP-24VBinaryOperationMode OCTET STRING
  wtWebioEA2x2ERP-24VBinaryTcpServerLocalPort INTEGER
  wtWebioEA2x2ERP-24VBinaryTcpServerInputTrigger OCTET STRING
  wtWebioEA2x2ERP-24VBinaryTcpServerApplicationMode OCTET STRING
  wtWebioEA2x2ERP-24VBinaryTcpClientLocalPort INTEGER
  wtWebioEA2x2ERP-24VBinaryTcpClientServerPort INTEGER
  wtWebioEA2x2ERP-24VBinaryTcpClientServerIpAddr OCTET STRING
  wtWebioEA2x2ERP-24VBinaryTcpClientServerPassword OCTET STRING
  wtWebioEA2x2ERP-24VBinaryTcpClientInactivity INTEGER
  wtWebioEA2x2ERP-24VBinaryTcpClientInputTrigger OCTET STRING
  wtWebioEA2x2ERP-24VBinaryTcpClientInterval INTEGER
  wtWebioEA2x2ERP-24VBinaryTcpClientApplicationMode OCTET STRING
  wtWebioEA2x2ERP-24VBinaryUdpPeerLocalPort INTEGER
  wtWebioEA2x2ERP-24VBinaryUdpPeerRemotePort INTEGER
  wtWebioEA2x2ERP-24VBinaryUdpPeerRemoteIpAddr OCTET STRING
  wtWebioEA2x2ERP-24VBinaryUdpPeerInputTrigger OCTET STRING
  wtWebioEA2x2ERP-24VBinaryUdpPeerInterval INTEGER
  wtWebioEA2x2ERP-24VBinaryUdpPeerApplicationMode OCTET STRING
  wtWebioEA2x2ERP-24VBinaryConnectedPort INTEGER
  wtWebioEA2x2ERP-24VBinaryConnectedIpAddr IpAddress
  wtWebioEA2x2ERP-24VBinaryTcpServerClientHttpPort INTEGER
  wtWebioEA2x2ERP-24VBinaryTcpClientServerHttpPort INTEGER

WtWebioEA2x2ERP-24VOutputModeEntry  
SEQUENCE    
  wtWebioEA2x2ERP-24VOutputModeBit OCTET STRING

WtWebioEA2x2ERP-24VAlarmIfEntry  
SEQUENCE    
  wtWebioEA2x2ERP-24VAlarmNo INTEGER

WtWebioEA2x2ERP-24VAlarmEntry  
SEQUENCE    
  wtWebioEA2x2ERP-24VAlarmInputTrigger OCTET STRING
  wtWebioEA2x2ERP-24VAlarmOutputTrigger OCTET STRING
  wtWebioEA2x2ERP-24VAlarmSystemTrigger OCTET STRING
  wtWebioEA2x2ERP-24VAlarmMaxCounterValue OCTET STRING
  wtWebioEA2x2ERP-24VAlarmInterval OCTET STRING
  wtWebioEA2x2ERP-24VAlarmEnable OCTET STRING
  wtWebioEA2x2ERP-24VAlarmMailAddr OCTET STRING
  wtWebioEA2x2ERP-24VAlarmMailSubject OCTET STRING
  wtWebioEA2x2ERP-24VAlarmMailText OCTET STRING
  wtWebioEA2x2ERP-24VAlarmSnmpManagerIP OCTET STRING
  wtWebioEA2x2ERP-24VAlarmSnmpTrapText OCTET STRING
  wtWebioEA2x2ERP-24VAlarmUdpIpAddr OCTET STRING
  wtWebioEA2x2ERP-24VAlarmUdpPort INTEGER
  wtWebioEA2x2ERP-24VAlarmUdpText OCTET STRING
  wtWebioEA2x2ERP-24VAlarmTcpIpAddr OCTET STRING
  wtWebioEA2x2ERP-24VAlarmTcpPort INTEGER
  wtWebioEA2x2ERP-24VAlarmTcpText OCTET STRING
  wtWebioEA2x2ERP-24VAlarmSyslogIpAddr OCTET STRING
  wtWebioEA2x2ERP-24VAlarmSyslogPort INTEGER
  wtWebioEA2x2ERP-24VAlarmSyslogText OCTET STRING
  wtWebioEA2x2ERP-24VAlarmFtpDataPort OCTET STRING
  wtWebioEA2x2ERP-24VAlarmFtpFileName OCTET STRING
  wtWebioEA2x2ERP-24VAlarmFtpText OCTET STRING
  wtWebioEA2x2ERP-24VAlarmFtpOption OCTET STRING
  wtWebioEA2x2ERP-24VAlarmTimerCron OCTET STRING
  wtWebioEA2x2ERP-24VAlarmMailReleaseSubject OCTET STRING
  wtWebioEA2x2ERP-24VAlarmMailReleaseText OCTET STRING
  wtWebioEA2x2ERP-24VAlarmSnmpTrapReleaseText OCTET STRING
  wtWebioEA2x2ERP-24VAlarmUdpReleaseText OCTET STRING
  wtWebioEA2x2ERP-24VAlarmTcpReleaseText OCTET STRING
  wtWebioEA2x2ERP-24VAlarmSyslogReleaseText OCTET STRING
  wtWebioEA2x2ERP-24VAlarmFtpReleaseText OCTET STRING

WtWebioEA2x2ERP-24VInputPortEntry  
SEQUENCE    
  wtWebioEA2x2ERP-24VPortInputName OCTET STRING
  wtWebioEA2x2ERP-24VPortInputText OCTET STRING
  wtWebioEA2x2ERP-24VPortInputMode OCTET STRING
  wtWebioEA2x2ERP-24VPortInputFilter INTEGER
  wtWebioEA2x2ERP-24VPortInputBicountPulsePolarity OCTET STRING
  wtWebioEA2x2ERP-24VPortInputBicountInactivTimeout INTEGER

WtWebioEA2x2ERP-24VOutputPortEntry  
SEQUENCE    
  wtWebioEA2x2ERP-24VPortOutputName OCTET STRING
  wtWebioEA2x2ERP-24VPortOutputText OCTET STRING
  wtWebioEA2x2ERP-24VPortOutputGroupMode OCTET STRING
  wtWebioEA2x2ERP-24VPortOutputSafetyState OCTET STRING
  wtWebioEA2x2ERP-24VPortLogicInputMask OCTET STRING
  wtWebioEA2x2ERP-24VPortLogicInputInverter OCTET STRING
  wtWebioEA2x2ERP-24VPortLogicFunction OCTET STRING
  wtWebioEA2x2ERP-24VPortLogicOutputInverter OCTET STRING
  wtWebioEA2x2ERP-24VPortPulseDuration INTEGER
  wtWebioEA2x2ERP-24VPortPulsePolarity OCTET STRING

WtIpWatcher-24VInputEntry  
SEQUENCE    
  wtIpWatcher-24VInputNo INTEGER
  wtIpWatcher-24VInputCounter INTEGER
  wtIpWatcher-24VInputCounterClear INTEGER
  wtIpWatcher-24VInputState INTEGER

WtIpWatcher-24VOutputEntry  
SEQUENCE    
  wtIpWatcher-24VOutputNo INTEGER
  wtIpWatcher-24VOutputState INTEGER

WtIpWatcher-24VAlarmOutputEntry  
SEQUENCE    
  wtIpWatcher-24VAlarmOutputState INTEGER
  wtIpWatcher-24VAlarmTriggerState INTEGER

WtIpWatcher-24VIpListIfEntry  
SEQUENCE    
  wtIpWatcher-24VIpListNo INTEGER

WtIpWatcher-24VIpListEntry  
SEQUENCE    
  wtIpWatcher-24VIpListName OCTET STRING
  wtIpWatcher-24VIpListPort INTEGER
  wtIpWatcher-24VIpListService OCTET STRING
  wtIpWatcher-24VIpListEnable OCTET STRING
  wtIpWatcher-24VIpListAlias OCTET STRING

WtIpWatcher-24VAlarmIfEntry  
SEQUENCE    
  wtIpWatcher-24VAlarmNo INTEGER

WtIpWatcher-24VAlarmEntry  
SEQUENCE    
  wtIpWatcher-24VAlarmInterval OCTET STRING
  wtIpWatcher-24VAlarmEnable OCTET STRING
  wtIpWatcher-24VAlarmMailAddr OCTET STRING
  wtIpWatcher-24VAlarmMailSubject OCTET STRING
  wtIpWatcher-24VAlarmMailText OCTET STRING
  wtIpWatcher-24VAlarmSnmpManagerIP OCTET STRING
  wtIpWatcher-24VAlarmSnmpTrapText OCTET STRING
  wtIpWatcher-24VAlarmUdpIpAddr OCTET STRING
  wtIpWatcher-24VAlarmUdpPort INTEGER
  wtIpWatcher-24VAlarmUdpText OCTET STRING
  wtIpWatcher-24VAlarmTcpIpAddr OCTET STRING
  wtIpWatcher-24VAlarmTcpPort INTEGER
  wtIpWatcher-24VAlarmTcpText OCTET STRING
  wtIpWatcher-24VAlarmSyslogIpAddr OCTET STRING
  wtIpWatcher-24VAlarmSyslogPort INTEGER
  wtIpWatcher-24VAlarmSyslogText OCTET STRING
  wtIpWatcher-24VAlarmFtpDataPort OCTET STRING
  wtIpWatcher-24VAlarmFtpFileName OCTET STRING
  wtIpWatcher-24VAlarmFtpText OCTET STRING
  wtIpWatcher-24VAlarmFtpOption OCTET STRING
  wtIpWatcher-24VAlarmTimerCron OCTET STRING
  wtIpWatcher-24VAlarmMailReleaseSubject OCTET STRING
  wtIpWatcher-24VAlarmMailReleaseText OCTET STRING
  wtIpWatcher-24VAlarmSnmpTrapReleaseText OCTET STRING
  wtIpWatcher-24VAlarmUdpReleaseText OCTET STRING
  wtIpWatcher-24VAlarmTcpReleaseText OCTET STRING
  wtIpWatcher-24VAlarmSyslogReleaseText OCTET STRING
  wtIpWatcher-24VAlarmFtpReleaseText OCTET STRING
  wtIpWatcher-24VAlarmName OCTET STRING
  wtIpWatcher-24VAlarmGlobalEnable OCTET STRING
  wtIpWatcher-24VAlarmCounterClear OCTET STRING
  wtIpWatcher-24VAlarmAckEnable OCTET STRING
  wtIpWatcher-24VAlarmAckPort INTEGER
  wtIpWatcher-24VAlarmSetPort INTEGER
  wtIpWatcher-24VAlarmMailTrgClearSubject OCTET STRING
  wtIpWatcher-24VAlarmMailTrgClearText OCTET STRING
  wtIpWatcher-24VAlarmSnmpTrapTrgClearText OCTET STRING
  wtIpWatcher-24VAlarmUdpTrgClearText OCTET STRING
  wtIpWatcher-24VAlarmTcpTrgClearText OCTET STRING
  wtIpWatcher-24VAlarmSyslogTrgClearText OCTET STRING
  wtIpWatcher-24VAlarmFtpTrgClearText OCTET STRING
  wtIpWatcher-24VAlarmMailTrapTxEnable OCTET STRING
  wtIpWatcher-24VAlarmSnmpTrapTrapTxEnable OCTET STRING
  wtIpWatcher-24VAlarmUdpTrapTxEnable OCTET STRING
  wtIpWatcher-24VAlarmTcpTrapTxEnable OCTET STRING
  wtIpWatcher-24VAlarmSyslogTrapTxEnable OCTET STRING
  wtIpWatcher-24VAlarmFtpTrapTxEnable OCTET STRING
  wtIpWatcher-24VAlarmTriggerCount INTEGER
  wtIpWatcher-24VAlarmPollingRate INTEGER

WtIpWatcher-24VInputPortEntry  
SEQUENCE    
  wtIpWatcher-24VPortInputName OCTET STRING
  wtIpWatcher-24VPortInputText OCTET STRING
  wtIpWatcher-24VPortInputFilter INTEGER

WtIpWatcher-24VOutputPortEntry  
SEQUENCE    
  wtIpWatcher-24VPortOutputName OCTET STRING
  wtIpWatcher-24VPortOutputText OCTET STRING
  wtIpWatcher-24VPortPulseDuration INTEGER
  wtIpWatcher-24VPortPulsePolarity OCTET STRING

WtTrapReceiver2x2InputEntry  
SEQUENCE    
  wtTrapReceiver2x2InputNo INTEGER
  wtTrapReceiver2x2InputState INTEGER

WtTrapReceiver2x2OutputEntry  
SEQUENCE    
  wtTrapReceiver2x2OutputNo INTEGER
  wtTrapReceiver2x2OutputState INTEGER

WtTrapReceiver2x2ActionOutputEntry  
SEQUENCE    
  wtTrapReceiver2x2ActionOutputState INTEGER
  wtTrapReceiver2x2ActionTriggerState INTEGER

WtTrapReceiver2x2SystemTimerEntry  
SEQUENCE    
  wtTrapReceiver2x2SystemTimerNo INTEGER

WtTrapReceiver2x2ButtonEntry  
SEQUENCE    
  wtTrapReceiver2x2ButtonNo INTEGER

WtTrapReceiver2x2WatchListIfEntry  
SEQUENCE    
  wtTrapReceiver2x2WatchListNo INTEGER

WtTrapReceiver2x2WatchListEntry  
SEQUENCE    
  wtTrapReceiver2x2WatchListName OCTET STRING
  wtTrapReceiver2x2WatchListPort INTEGER
  wtTrapReceiver2x2WatchListService OCTET STRING
  wtTrapReceiver2x2WatchListEnable OCTET STRING
  wtTrapReceiver2x2WatchListAlias OCTET STRING
  wtTrapReceiver2x2WatchListTrapNo INTEGER
  wtTrapReceiver2x2WatchListSpecificNo INTEGER
  wtTrapReceiver2x2WatchListFacility INTEGER
  wtTrapReceiver2x2WatchListSeverity INTEGER

WtTrapReceiver2x2ActionIfEntry  
SEQUENCE    
  wtTrapReceiver2x2ActionNo INTEGER

WtTrapReceiver2x2ActionEntry  
SEQUENCE    
  wtTrapReceiver2x2ActionInputTrigger OCTET STRING
  wtTrapReceiver2x2ActionInterval OCTET STRING
  wtTrapReceiver2x2ActionEnable OCTET STRING
  wtTrapReceiver2x2ActionMailAddr OCTET STRING
  wtTrapReceiver2x2ActionMailSubject OCTET STRING
  wtTrapReceiver2x2ActionMailText OCTET STRING
  wtTrapReceiver2x2ActionSnmpManagerIP OCTET STRING
  wtTrapReceiver2x2ActionSnmpTrapText OCTET STRING
  wtTrapReceiver2x2ActionUdpIpAddr OCTET STRING
  wtTrapReceiver2x2ActionUdpPort INTEGER
  wtTrapReceiver2x2ActionUdpText OCTET STRING
  wtTrapReceiver2x2ActionTcpIpAddr OCTET STRING
  wtTrapReceiver2x2ActionTcpPort INTEGER
  wtTrapReceiver2x2ActionTcpText OCTET STRING
  wtTrapReceiver2x2ActionSyslogIpAddr OCTET STRING
  wtTrapReceiver2x2ActionSyslogPort INTEGER
  wtTrapReceiver2x2ActionSyslogText OCTET STRING
  wtTrapReceiver2x2ActionFtpDataPort OCTET STRING
  wtTrapReceiver2x2ActionFtpFileName OCTET STRING
  wtTrapReceiver2x2ActionFtpText OCTET STRING
  wtTrapReceiver2x2ActionFtpOption OCTET STRING
  wtTrapReceiver2x2ActionTimerCron OCTET STRING
  wtTrapReceiver2x2ActionName OCTET STRING
  wtTrapReceiver2x2ActionGlobalEnable OCTET STRING
  wtTrapReceiver2x2ActionSystemTimerTrigger OCTET STRING
  wtTrapReceiver2x2ActionSystemButtonTrigger OCTET STRING
  wtTrapReceiver2x2ActionOutputAction OCTET STRING

WtTrapReceiver2x2SystemTimerPortEntry  
SEQUENCE    
  wtTrapReceiver2x2PortSystemTimerEnable OCTET STRING
  wtTrapReceiver2x2PortSystemTimerName OCTET STRING
  wtTrapReceiver2x2PortSystemTimerCron OCTET STRING

WtTrapReceiver2x2ButtonPortEntry  
SEQUENCE    
  wtTrapReceiver2x2PortButtonEnable OCTET STRING
  wtTrapReceiver2x2PortButtonName OCTET STRING
  wtTrapReceiver2x2PortButtonText OCTET STRING
  wtTrapReceiver2x2PortButtonAccess OCTET STRING

WtTrapReceiver2x2InputPortEntry  
SEQUENCE    
  wtTrapReceiver2x2PortInputName OCTET STRING
  wtTrapReceiver2x2PortInputText OCTET STRING
  wtTrapReceiver2x2PortInputFilter INTEGER

WtTrapReceiver2x2OutputPortEntry  
SEQUENCE    
  wtTrapReceiver2x2PortOutputName OCTET STRING
  wtTrapReceiver2x2PortOutputText OCTET STRING
  wtTrapReceiver2x2PortPulseDuration INTEGER
  wtTrapReceiver2x2PortPulsePolarity OCTET STRING

Defined Values

wut 1.3.6.1.4.1.5040
OBJECT IDENTIFIER    

wtComServer 1.3.6.1.4.1.5040.1
OBJECT IDENTIFIER    

wtWebio 1.3.6.1.4.1.5040.1.2
OBJECT IDENTIFIER    

wtWebioEA12x12 1.3.6.1.4.1.5040.1.2.4
OBJECT IDENTIFIER    

wtWebioEA2x2 1.3.6.1.4.1.5040.1.2.13
OBJECT IDENTIFIER    

wtWebioEA24oem 1.3.6.1.4.1.5040.1.2.14
OBJECT IDENTIFIER    

wtWebioEA12x6Rel 1.3.6.1.4.1.5040.1.2.19
OBJECT IDENTIFIER    

wtWebAlarm6x6 1.3.6.1.4.1.5040.1.2.20
OBJECT IDENTIFIER    

wtWebCount6 1.3.6.1.4.1.5040.1.2.22
OBJECT IDENTIFIER    

wtWebioEA6x6 1.3.6.1.4.1.5040.1.2.24
OBJECT IDENTIFIER    

wtWebioEA2x2ERP 1.3.6.1.4.1.5040.1.2.25
OBJECT IDENTIFIER    

wtWebioEA12x6RelERP 1.3.6.1.4.1.5040.1.2.26
OBJECT IDENTIFIER    

wtIpWatcher 1.3.6.1.4.1.5040.1.2.27
OBJECT IDENTIFIER    

wtWebioEA2x2-24V 1.3.6.1.4.1.5040.1.2.30
OBJECT IDENTIFIER    

wtWebioEA2x2ERP-24V 1.3.6.1.4.1.5040.1.2.31
OBJECT IDENTIFIER    

wtIpWatcher-24V 1.3.6.1.4.1.5040.1.2.32
OBJECT IDENTIFIER    

wtTrapReceiver2x2 1.3.6.1.4.1.5040.1.2.33
OBJECT IDENTIFIER    

wtWebioEA2x2InOut 1.3.6.1.4.1.5040.1.2.13.1
OBJECT IDENTIFIER    

wtWebioEA2x2SessCntrl 1.3.6.1.4.1.5040.1.2.13.2
OBJECT IDENTIFIER    

wtWebioEA2x2Config 1.3.6.1.4.1.5040.1.2.13.3
OBJECT IDENTIFIER    

wtWebioEA2x2Diag 1.3.6.1.4.1.5040.1.2.13.4
OBJECT IDENTIFIER    

wtWebioEA2x2Device 1.3.6.1.4.1.5040.1.2.13.3.1
OBJECT IDENTIFIER    

wtWebioEA2x2Ports 1.3.6.1.4.1.5040.1.2.13.3.2
OBJECT IDENTIFIER    

wtWebioEA2x2Manufact 1.3.6.1.4.1.5040.1.2.13.3.3
OBJECT IDENTIFIER    

wtWebioEA2x2Text 1.3.6.1.4.1.5040.1.2.13.3.1.1
OBJECT IDENTIFIER    

wtWebioEA2x2TimeDate 1.3.6.1.4.1.5040.1.2.13.3.1.2
OBJECT IDENTIFIER    

wtWebioEA2x2Basic 1.3.6.1.4.1.5040.1.2.13.3.1.3
OBJECT IDENTIFIER    

wtWebioEA2x2OutputMode 1.3.6.1.4.1.5040.1.2.13.3.1.4
OBJECT IDENTIFIER    

wtWebioEA2x2Alarm 1.3.6.1.4.1.5040.1.2.13.3.1.5
OBJECT IDENTIFIER    

wtWebioEA2x2Network 1.3.6.1.4.1.5040.1.2.13.3.1.3.1
OBJECT IDENTIFIER    

wtWebioEA2x2HTTP 1.3.6.1.4.1.5040.1.2.13.3.1.3.2
OBJECT IDENTIFIER    

wtWebioEA2x2Mail 1.3.6.1.4.1.5040.1.2.13.3.1.3.3
OBJECT IDENTIFIER    

wtWebioEA2x2SNMP 1.3.6.1.4.1.5040.1.2.13.3.1.3.4
OBJECT IDENTIFIER    

wtWebioEA2x2UDP 1.3.6.1.4.1.5040.1.2.13.3.1.3.5
OBJECT IDENTIFIER    

wtWebioEA2x2Binary 1.3.6.1.4.1.5040.1.2.13.3.1.3.6
OBJECT IDENTIFIER    

wtWebioEA2x2Syslog 1.3.6.1.4.1.5040.1.2.13.3.1.3.7
OBJECT IDENTIFIER    

wtWebioEA2x2FTP 1.3.6.1.4.1.5040.1.2.13.3.1.3.8
OBJECT IDENTIFIER    

wtWebioEA2x2TimeZone 1.3.6.1.4.1.5040.1.2.13.3.1.2.1
OBJECT IDENTIFIER    

wtWebioEA2x2TimeServer 1.3.6.1.4.1.5040.1.2.13.3.1.2.2
OBJECT IDENTIFIER    

wtWebioEA2x2DeviceClock 1.3.6.1.4.1.5040.1.2.13.3.1.2.3
OBJECT IDENTIFIER    

wtWebioEA12x12InOut 1.3.6.1.4.1.5040.1.2.4.1
OBJECT IDENTIFIER    

wtWebioEA12x12SessCntrl 1.3.6.1.4.1.5040.1.2.4.2
OBJECT IDENTIFIER    

wtWebioEA12x12Config 1.3.6.1.4.1.5040.1.2.4.3
OBJECT IDENTIFIER    

wtWebioEA12x12Diag 1.3.6.1.4.1.5040.1.2.4.4
OBJECT IDENTIFIER    

wtWebioEA12x12Device 1.3.6.1.4.1.5040.1.2.4.3.1
OBJECT IDENTIFIER    

wtWebioEA12x12Ports 1.3.6.1.4.1.5040.1.2.4.3.2
OBJECT IDENTIFIER    

wtWebioEA12x12Manufact 1.3.6.1.4.1.5040.1.2.4.3.3
OBJECT IDENTIFIER    

wtWebioEA12x12Text 1.3.6.1.4.1.5040.1.2.4.3.1.1
OBJECT IDENTIFIER    

wtWebioEA12x12TimeDate 1.3.6.1.4.1.5040.1.2.4.3.1.2
OBJECT IDENTIFIER    

wtWebioEA12x12Basic 1.3.6.1.4.1.5040.1.2.4.3.1.3
OBJECT IDENTIFIER    

wtWebioEA12x12OutputMode 1.3.6.1.4.1.5040.1.2.4.3.1.4
OBJECT IDENTIFIER    

wtWebioEA12x12Alarm 1.3.6.1.4.1.5040.1.2.4.3.1.5
OBJECT IDENTIFIER    

wtWebioEA12x12Network 1.3.6.1.4.1.5040.1.2.4.3.1.3.1
OBJECT IDENTIFIER    

wtWebioEA12x12HTTP 1.3.6.1.4.1.5040.1.2.4.3.1.3.2
OBJECT IDENTIFIER    

wtWebioEA12x12Mail 1.3.6.1.4.1.5040.1.2.4.3.1.3.3
OBJECT IDENTIFIER    

wtWebioEA12x12SNMP 1.3.6.1.4.1.5040.1.2.4.3.1.3.4
OBJECT IDENTIFIER    

wtWebioEA12x12UDP 1.3.6.1.4.1.5040.1.2.4.3.1.3.5
OBJECT IDENTIFIER    

wtWebioEA12x12Binary 1.3.6.1.4.1.5040.1.2.4.3.1.3.6
OBJECT IDENTIFIER    

wtWebioEA12x12Syslog 1.3.6.1.4.1.5040.1.2.4.3.1.3.7
OBJECT IDENTIFIER    

wtWebioEA12x12FTP 1.3.6.1.4.1.5040.1.2.4.3.1.3.8
OBJECT IDENTIFIER    

wtWebioEA12x12TimeZone 1.3.6.1.4.1.5040.1.2.4.3.1.2.1
OBJECT IDENTIFIER    

wtWebioEA12x12TimeServer 1.3.6.1.4.1.5040.1.2.4.3.1.2.2
OBJECT IDENTIFIER    

wtWebioEA12x12DeviceClock 1.3.6.1.4.1.5040.1.2.4.3.1.2.3
OBJECT IDENTIFIER    

wtWebioEA24oemInOut 1.3.6.1.4.1.5040.1.2.14.1
OBJECT IDENTIFIER    

wtWebioEA24oemSessCntrl 1.3.6.1.4.1.5040.1.2.14.2
OBJECT IDENTIFIER    

wtWebioEA24oemConfig 1.3.6.1.4.1.5040.1.2.14.3
OBJECT IDENTIFIER    

wtWebioEA24oemDiag 1.3.6.1.4.1.5040.1.2.14.4
OBJECT IDENTIFIER    

wtWebioEA24oemDevice 1.3.6.1.4.1.5040.1.2.14.3.1
OBJECT IDENTIFIER    

wtWebioEA24oemPorts 1.3.6.1.4.1.5040.1.2.14.3.2
OBJECT IDENTIFIER    

wtWebioEA24oemManufact 1.3.6.1.4.1.5040.1.2.14.3.3
OBJECT IDENTIFIER    

wtWebioEA24oemText 1.3.6.1.4.1.5040.1.2.14.3.1.1
OBJECT IDENTIFIER    

wtWebioEA24oemTimeDate 1.3.6.1.4.1.5040.1.2.14.3.1.2
OBJECT IDENTIFIER    

wtWebioEA24oemBasic 1.3.6.1.4.1.5040.1.2.14.3.1.3
OBJECT IDENTIFIER    

wtWebioEA24oemOutputMode 1.3.6.1.4.1.5040.1.2.14.3.1.4
OBJECT IDENTIFIER    

wtWebioEA24oemAlarm 1.3.6.1.4.1.5040.1.2.14.3.1.5
OBJECT IDENTIFIER    

wtWebioEA24oemNetwork 1.3.6.1.4.1.5040.1.2.14.3.1.3.1
OBJECT IDENTIFIER    

wtWebioEA24oemHTTP 1.3.6.1.4.1.5040.1.2.14.3.1.3.2
OBJECT IDENTIFIER    

wtWebioEA24oemMail 1.3.6.1.4.1.5040.1.2.14.3.1.3.3
OBJECT IDENTIFIER    

wtWebioEA24oemSNMP 1.3.6.1.4.1.5040.1.2.14.3.1.3.4
OBJECT IDENTIFIER    

wtWebioEA24oemUDP 1.3.6.1.4.1.5040.1.2.14.3.1.3.5
OBJECT IDENTIFIER    

wtWebioEA24oemBinary 1.3.6.1.4.1.5040.1.2.14.3.1.3.6
OBJECT IDENTIFIER    

wtWebioEA24oemSyslog 1.3.6.1.4.1.5040.1.2.14.3.1.3.7
OBJECT IDENTIFIER    

wtWebioEA24oemFTP 1.3.6.1.4.1.5040.1.2.14.3.1.3.8
OBJECT IDENTIFIER    

wtWebioEA24oemTimeZone 1.3.6.1.4.1.5040.1.2.14.3.1.2.1
OBJECT IDENTIFIER    

wtWebioEA24oemTimeServer 1.3.6.1.4.1.5040.1.2.14.3.1.2.2
OBJECT IDENTIFIER    

wtWebioEA24oemDeviceClock 1.3.6.1.4.1.5040.1.2.14.3.1.2.3
OBJECT IDENTIFIER    

wtWebioEA12x6RelInOut 1.3.6.1.4.1.5040.1.2.19.1
OBJECT IDENTIFIER    

wtWebioEA12x6RelSessCntrl 1.3.6.1.4.1.5040.1.2.19.2
OBJECT IDENTIFIER    

wtWebioEA12x6RelConfig 1.3.6.1.4.1.5040.1.2.19.3
OBJECT IDENTIFIER    

wtWebioEA12x6RelDiag 1.3.6.1.4.1.5040.1.2.19.4
OBJECT IDENTIFIER    

wtWebioEA12x6RelDevice 1.3.6.1.4.1.5040.1.2.19.3.1
OBJECT IDENTIFIER    

wtWebioEA12x6RelPorts 1.3.6.1.4.1.5040.1.2.19.3.2
OBJECT IDENTIFIER    

wtWebioEA12x6RelManufact 1.3.6.1.4.1.5040.1.2.19.3.3
OBJECT IDENTIFIER    

wtWebioEA12x6RelText 1.3.6.1.4.1.5040.1.2.19.3.1.1
OBJECT IDENTIFIER    

wtWebioEA12x6RelTimeDate 1.3.6.1.4.1.5040.1.2.19.3.1.2
OBJECT IDENTIFIER    

wtWebioEA12x6RelBasic 1.3.6.1.4.1.5040.1.2.19.3.1.3
OBJECT IDENTIFIER    

wtWebioEA12x6RelOutputMode 1.3.6.1.4.1.5040.1.2.19.3.1.4
OBJECT IDENTIFIER    

wtWebioEA12x6RelAlarm 1.3.6.1.4.1.5040.1.2.19.3.1.5
OBJECT IDENTIFIER    

wtWebioEA12x6RelNetwork 1.3.6.1.4.1.5040.1.2.19.3.1.3.1
OBJECT IDENTIFIER    

wtWebioEA12x6RelHTTP 1.3.6.1.4.1.5040.1.2.19.3.1.3.2
OBJECT IDENTIFIER    

wtWebioEA12x6RelMail 1.3.6.1.4.1.5040.1.2.19.3.1.3.3
OBJECT IDENTIFIER    

wtWebioEA12x6RelSNMP 1.3.6.1.4.1.5040.1.2.19.3.1.3.4
OBJECT IDENTIFIER    

wtWebioEA12x6RelUDP 1.3.6.1.4.1.5040.1.2.19.3.1.3.5
OBJECT IDENTIFIER    

wtWebioEA12x6RelBinary 1.3.6.1.4.1.5040.1.2.19.3.1.3.6
OBJECT IDENTIFIER    

wtWebioEA12x6RelSyslog 1.3.6.1.4.1.5040.1.2.19.3.1.3.7
OBJECT IDENTIFIER    

wtWebioEA12x6RelFTP 1.3.6.1.4.1.5040.1.2.19.3.1.3.8
OBJECT IDENTIFIER    

wtWebioEA12x6RelTimeZone 1.3.6.1.4.1.5040.1.2.19.3.1.2.1
OBJECT IDENTIFIER    

wtWebioEA12x6RelTimeServer 1.3.6.1.4.1.5040.1.2.19.3.1.2.2
OBJECT IDENTIFIER    

wtWebioEA12x6RelDeviceClock 1.3.6.1.4.1.5040.1.2.19.3.1.2.3
OBJECT IDENTIFIER    

wtWebAlarm6x6InOut 1.3.6.1.4.1.5040.1.2.20.1
OBJECT IDENTIFIER    

wtWebAlarm6x6SessCntrl 1.3.6.1.4.1.5040.1.2.20.2
OBJECT IDENTIFIER    

wtWebAlarm6x6Config 1.3.6.1.4.1.5040.1.2.20.3
OBJECT IDENTIFIER    

wtWebAlarm6x6Diag 1.3.6.1.4.1.5040.1.2.20.4
OBJECT IDENTIFIER    

wtWebAlarm6x6Device 1.3.6.1.4.1.5040.1.2.20.3.1
OBJECT IDENTIFIER    

wtWebAlarm6x6Ports 1.3.6.1.4.1.5040.1.2.20.3.2
OBJECT IDENTIFIER    

wtWebAlarm6x6Manufact 1.3.6.1.4.1.5040.1.2.20.3.3
OBJECT IDENTIFIER    

wtWebAlarm6x6Text 1.3.6.1.4.1.5040.1.2.20.3.1.1
OBJECT IDENTIFIER    

wtWebAlarm6x6TimeDate 1.3.6.1.4.1.5040.1.2.20.3.1.2
OBJECT IDENTIFIER    

wtWebAlarm6x6Basic 1.3.6.1.4.1.5040.1.2.20.3.1.3
OBJECT IDENTIFIER    

wtWebAlarm6x6Alarm 1.3.6.1.4.1.5040.1.2.20.3.1.5
OBJECT IDENTIFIER    

wtWebAlarm6x6Network 1.3.6.1.4.1.5040.1.2.20.3.1.3.1
OBJECT IDENTIFIER    

wtWebAlarm6x6HTTP 1.3.6.1.4.1.5040.1.2.20.3.1.3.2
OBJECT IDENTIFIER    

wtWebAlarm6x6Mail 1.3.6.1.4.1.5040.1.2.20.3.1.3.3
OBJECT IDENTIFIER    

wtWebAlarm6x6SNMP 1.3.6.1.4.1.5040.1.2.20.3.1.3.4
OBJECT IDENTIFIER    

wtWebAlarm6x6UDP 1.3.6.1.4.1.5040.1.2.20.3.1.3.5
OBJECT IDENTIFIER    

wtWebAlarm6x6Syslog 1.3.6.1.4.1.5040.1.2.20.3.1.3.7
OBJECT IDENTIFIER    

wtWebAlarm6x6FTP 1.3.6.1.4.1.5040.1.2.20.3.1.3.8
OBJECT IDENTIFIER    

wtWebAlarm6x6TimeZone 1.3.6.1.4.1.5040.1.2.20.3.1.2.1
OBJECT IDENTIFIER    

wtWebAlarm6x6TimeServer 1.3.6.1.4.1.5040.1.2.20.3.1.2.2
OBJECT IDENTIFIER    

wtWebAlarm6x6DeviceClock 1.3.6.1.4.1.5040.1.2.20.3.1.2.3
OBJECT IDENTIFIER    

wtWebCount6InOut 1.3.6.1.4.1.5040.1.2.22.1
OBJECT IDENTIFIER    

wtWebCount6SessCntrl 1.3.6.1.4.1.5040.1.2.22.2
OBJECT IDENTIFIER    

wtWebCount6Config 1.3.6.1.4.1.5040.1.2.22.3
OBJECT IDENTIFIER    

wtWebCount6Diag 1.3.6.1.4.1.5040.1.2.22.4
OBJECT IDENTIFIER    

wtWebCount6Device 1.3.6.1.4.1.5040.1.2.22.3.1
OBJECT IDENTIFIER    

wtWebCount6Ports 1.3.6.1.4.1.5040.1.2.22.3.2
OBJECT IDENTIFIER    

wtWebCount6Manufact 1.3.6.1.4.1.5040.1.2.22.3.3
OBJECT IDENTIFIER    

wtWebCount6Text 1.3.6.1.4.1.5040.1.2.22.3.1.1
OBJECT IDENTIFIER    

wtWebCount6TimeDate 1.3.6.1.4.1.5040.1.2.22.3.1.2
OBJECT IDENTIFIER    

wtWebCount6Basic 1.3.6.1.4.1.5040.1.2.22.3.1.3
OBJECT IDENTIFIER    

wtWebCount6Report 1.3.6.1.4.1.5040.1.2.22.3.1.5
OBJECT IDENTIFIER    

wtWebCount6Network 1.3.6.1.4.1.5040.1.2.22.3.1.3.1
OBJECT IDENTIFIER    

wtWebCount6HTTP 1.3.6.1.4.1.5040.1.2.22.3.1.3.2
OBJECT IDENTIFIER    

wtWebCount6Mail 1.3.6.1.4.1.5040.1.2.22.3.1.3.3
OBJECT IDENTIFIER    

wtWebCount6SNMP 1.3.6.1.4.1.5040.1.2.22.3.1.3.4
OBJECT IDENTIFIER    

wtWebCount6UDP 1.3.6.1.4.1.5040.1.2.22.3.1.3.5
OBJECT IDENTIFIER    

wtWebCount6Syslog 1.3.6.1.4.1.5040.1.2.22.3.1.3.7
OBJECT IDENTIFIER    

wtWebCount6FTP 1.3.6.1.4.1.5040.1.2.22.3.1.3.8
OBJECT IDENTIFIER    

wtWebCount6TimeZone 1.3.6.1.4.1.5040.1.2.22.3.1.2.1
OBJECT IDENTIFIER    

wtWebCount6TimeServer 1.3.6.1.4.1.5040.1.2.22.3.1.2.2
OBJECT IDENTIFIER    

wtWebCount6DeviceClock 1.3.6.1.4.1.5040.1.2.22.3.1.2.3
OBJECT IDENTIFIER    

wtWebioEA6x6InOut 1.3.6.1.4.1.5040.1.2.24.1
OBJECT IDENTIFIER    

wtWebioEA6x6SessCntrl 1.3.6.1.4.1.5040.1.2.24.2
OBJECT IDENTIFIER    

wtWebioEA6x6Config 1.3.6.1.4.1.5040.1.2.24.3
OBJECT IDENTIFIER    

wtWebioEA6x6Diag 1.3.6.1.4.1.5040.1.2.24.4
OBJECT IDENTIFIER    

wtWebioEA6x6Device 1.3.6.1.4.1.5040.1.2.24.3.1
OBJECT IDENTIFIER    

wtWebioEA6x6Ports 1.3.6.1.4.1.5040.1.2.24.3.2
OBJECT IDENTIFIER    

wtWebioEA6x6Manufact 1.3.6.1.4.1.5040.1.2.24.3.3
OBJECT IDENTIFIER    

wtWebioEA6x6Text 1.3.6.1.4.1.5040.1.2.24.3.1.1
OBJECT IDENTIFIER    

wtWebioEA6x6TimeDate 1.3.6.1.4.1.5040.1.2.24.3.1.2
OBJECT IDENTIFIER    

wtWebioEA6x6Basic 1.3.6.1.4.1.5040.1.2.24.3.1.3
OBJECT IDENTIFIER    

wtWebioEA6x6OutputMode 1.3.6.1.4.1.5040.1.2.24.3.1.4
OBJECT IDENTIFIER    

wtWebioEA6x6Alarm 1.3.6.1.4.1.5040.1.2.24.3.1.5
OBJECT IDENTIFIER    

wtWebioEA6x6Network 1.3.6.1.4.1.5040.1.2.24.3.1.3.1
OBJECT IDENTIFIER    

wtWebioEA6x6HTTP 1.3.6.1.4.1.5040.1.2.24.3.1.3.2
OBJECT IDENTIFIER    

wtWebioEA6x6Mail 1.3.6.1.4.1.5040.1.2.24.3.1.3.3
OBJECT IDENTIFIER    

wtWebioEA6x6SNMP 1.3.6.1.4.1.5040.1.2.24.3.1.3.4
OBJECT IDENTIFIER    

wtWebioEA6x6UDP 1.3.6.1.4.1.5040.1.2.24.3.1.3.5
OBJECT IDENTIFIER    

wtWebioEA6x6Binary 1.3.6.1.4.1.5040.1.2.24.3.1.3.6
OBJECT IDENTIFIER    

wtWebioEA6x6Syslog 1.3.6.1.4.1.5040.1.2.24.3.1.3.7
OBJECT IDENTIFIER    

wtWebioEA6x6FTP 1.3.6.1.4.1.5040.1.2.24.3.1.3.8
OBJECT IDENTIFIER    

wtWebioEA6x6TimeZone 1.3.6.1.4.1.5040.1.2.24.3.1.2.1
OBJECT IDENTIFIER    

wtWebioEA6x6TimeServer 1.3.6.1.4.1.5040.1.2.24.3.1.2.2
OBJECT IDENTIFIER    

wtWebioEA6x6DeviceClock 1.3.6.1.4.1.5040.1.2.24.3.1.2.3
OBJECT IDENTIFIER    

wtWebioEA2x2ERPInOut 1.3.6.1.4.1.5040.1.2.25.1
OBJECT IDENTIFIER    

wtWebioEA2x2ERPSessCntrl 1.3.6.1.4.1.5040.1.2.25.2
OBJECT IDENTIFIER    

wtWebioEA2x2ERPConfig 1.3.6.1.4.1.5040.1.2.25.3
OBJECT IDENTIFIER    

wtWebioEA2x2ERPDiag 1.3.6.1.4.1.5040.1.2.25.4
OBJECT IDENTIFIER    

wtWebioEA2x2ERPDevice 1.3.6.1.4.1.5040.1.2.25.3.1
OBJECT IDENTIFIER    

wtWebioEA2x2ERPPorts 1.3.6.1.4.1.5040.1.2.25.3.2
OBJECT IDENTIFIER    

wtWebioEA2x2ERPManufact 1.3.6.1.4.1.5040.1.2.25.3.3
OBJECT IDENTIFIER    

wtWebioEA2x2ERPText 1.3.6.1.4.1.5040.1.2.25.3.1.1
OBJECT IDENTIFIER    

wtWebioEA2x2ERPTimeDate 1.3.6.1.4.1.5040.1.2.25.3.1.2
OBJECT IDENTIFIER    

wtWebioEA2x2ERPBasic 1.3.6.1.4.1.5040.1.2.25.3.1.3
OBJECT IDENTIFIER    

wtWebioEA2x2ERPOutputMode 1.3.6.1.4.1.5040.1.2.25.3.1.4
OBJECT IDENTIFIER    

wtWebioEA2x2ERPAlarm 1.3.6.1.4.1.5040.1.2.25.3.1.5
OBJECT IDENTIFIER    

wtWebioEA2x2ERPNetwork 1.3.6.1.4.1.5040.1.2.25.3.1.3.1
OBJECT IDENTIFIER    

wtWebioEA2x2ERPHTTP 1.3.6.1.4.1.5040.1.2.25.3.1.3.2
OBJECT IDENTIFIER    

wtWebioEA2x2ERPMail 1.3.6.1.4.1.5040.1.2.25.3.1.3.3
OBJECT IDENTIFIER    

wtWebioEA2x2ERPSNMP 1.3.6.1.4.1.5040.1.2.25.3.1.3.4
OBJECT IDENTIFIER    

wtWebioEA2x2ERPUDP 1.3.6.1.4.1.5040.1.2.25.3.1.3.5
OBJECT IDENTIFIER    

wtWebioEA2x2ERPBinary 1.3.6.1.4.1.5040.1.2.25.3.1.3.6
OBJECT IDENTIFIER    

wtWebioEA2x2ERPSyslog 1.3.6.1.4.1.5040.1.2.25.3.1.3.7
OBJECT IDENTIFIER    

wtWebioEA2x2ERPFTP 1.3.6.1.4.1.5040.1.2.25.3.1.3.8
OBJECT IDENTIFIER    

wtWebioEA2x2ERPWayBack 1.3.6.1.4.1.5040.1.2.25.3.1.3.10
OBJECT IDENTIFIER    

wtWebioEA2x2ERPTimeZone 1.3.6.1.4.1.5040.1.2.25.3.1.2.1
OBJECT IDENTIFIER    

wtWebioEA2x2ERPTimeServer 1.3.6.1.4.1.5040.1.2.25.3.1.2.2
OBJECT IDENTIFIER    

wtWebioEA2x2ERPDeviceClock 1.3.6.1.4.1.5040.1.2.25.3.1.2.3
OBJECT IDENTIFIER    

wtWebioEA12x6RelERPInOut 1.3.6.1.4.1.5040.1.2.26.1
OBJECT IDENTIFIER    

wtWebioEA12x6RelERPSessCntrl 1.3.6.1.4.1.5040.1.2.26.2
OBJECT IDENTIFIER    

wtWebioEA12x6RelERPConfig 1.3.6.1.4.1.5040.1.2.26.3
OBJECT IDENTIFIER    

wtWebioEA12x6RelERPDiag 1.3.6.1.4.1.5040.1.2.26.4
OBJECT IDENTIFIER    

wtWebioEA12x6RelERPDevice 1.3.6.1.4.1.5040.1.2.26.3.1
OBJECT IDENTIFIER    

wtWebioEA12x6RelERPPorts 1.3.6.1.4.1.5040.1.2.26.3.2
OBJECT IDENTIFIER    

wtWebioEA12x6RelERPManufact 1.3.6.1.4.1.5040.1.2.26.3.3
OBJECT IDENTIFIER    

wtWebioEA12x6RelERPText 1.3.6.1.4.1.5040.1.2.26.3.1.1
OBJECT IDENTIFIER    

wtWebioEA12x6RelERPTimeDate 1.3.6.1.4.1.5040.1.2.26.3.1.2
OBJECT IDENTIFIER    

wtWebioEA12x6RelERPBasic 1.3.6.1.4.1.5040.1.2.26.3.1.3
OBJECT IDENTIFIER    

wtWebioEA12x6RelERPOutputMode 1.3.6.1.4.1.5040.1.2.26.3.1.4
OBJECT IDENTIFIER    

wtWebioEA12x6RelERPAlarm 1.3.6.1.4.1.5040.1.2.26.3.1.5
OBJECT IDENTIFIER    

wtWebioEA12x6RelERPNetwork 1.3.6.1.4.1.5040.1.2.26.3.1.3.1
OBJECT IDENTIFIER    

wtWebioEA12x6RelERPHTTP 1.3.6.1.4.1.5040.1.2.26.3.1.3.2
OBJECT IDENTIFIER    

wtWebioEA12x6RelERPMail 1.3.6.1.4.1.5040.1.2.26.3.1.3.3
OBJECT IDENTIFIER    

wtWebioEA12x6RelERPSNMP 1.3.6.1.4.1.5040.1.2.26.3.1.3.4
OBJECT IDENTIFIER    

wtWebioEA12x6RelERPUDP 1.3.6.1.4.1.5040.1.2.26.3.1.3.5
OBJECT IDENTIFIER    

wtWebioEA12x6RelERPBinary 1.3.6.1.4.1.5040.1.2.26.3.1.3.6
OBJECT IDENTIFIER    

wtWebioEA12x6RelERPSyslog 1.3.6.1.4.1.5040.1.2.26.3.1.3.7
OBJECT IDENTIFIER    

wtWebioEA12x6RelERPFTP 1.3.6.1.4.1.5040.1.2.26.3.1.3.8
OBJECT IDENTIFIER    

wtWebioEA12x6RelERPWayBack 1.3.6.1.4.1.5040.1.2.26.3.1.3.10
OBJECT IDENTIFIER    

wtWebioEA12x6RelERPTimeZone 1.3.6.1.4.1.5040.1.2.26.3.1.2.1
OBJECT IDENTIFIER    

wtWebioEA12x6RelERPTimeServer 1.3.6.1.4.1.5040.1.2.26.3.1.2.2
OBJECT IDENTIFIER    

wtWebioEA12x6RelERPDeviceClock 1.3.6.1.4.1.5040.1.2.26.3.1.2.3
OBJECT IDENTIFIER    

wtIpWatcherInOut 1.3.6.1.4.1.5040.1.2.27.1
OBJECT IDENTIFIER    

wtIpWatcherSessCntrl 1.3.6.1.4.1.5040.1.2.27.2
OBJECT IDENTIFIER    

wtIpWatcherConfig 1.3.6.1.4.1.5040.1.2.27.3
OBJECT IDENTIFIER    

wtIpWatcherDiag 1.3.6.1.4.1.5040.1.2.27.4
OBJECT IDENTIFIER    

wtIpWatcherDevice 1.3.6.1.4.1.5040.1.2.27.3.1
OBJECT IDENTIFIER    

wtIpWatcherPorts 1.3.6.1.4.1.5040.1.2.27.3.2
OBJECT IDENTIFIER    

wtIpWatcherManufact 1.3.6.1.4.1.5040.1.2.27.3.3
OBJECT IDENTIFIER    

wtIpWatcherText 1.3.6.1.4.1.5040.1.2.27.3.1.1
OBJECT IDENTIFIER    

wtIpWatcherTimeDate 1.3.6.1.4.1.5040.1.2.27.3.1.2
OBJECT IDENTIFIER    

wtIpWatcherBasic 1.3.6.1.4.1.5040.1.2.27.3.1.3
OBJECT IDENTIFIER    

wtIpWatcherAlarm 1.3.6.1.4.1.5040.1.2.27.3.1.5
OBJECT IDENTIFIER    

wtIpWatcherNetwork 1.3.6.1.4.1.5040.1.2.27.3.1.3.1
OBJECT IDENTIFIER    

wtIpWatcherHTTP 1.3.6.1.4.1.5040.1.2.27.3.1.3.2
OBJECT IDENTIFIER    

wtIpWatcherMail 1.3.6.1.4.1.5040.1.2.27.3.1.3.3
OBJECT IDENTIFIER    

wtIpWatcherSNMP 1.3.6.1.4.1.5040.1.2.27.3.1.3.4
OBJECT IDENTIFIER    

wtIpWatcherUDP 1.3.6.1.4.1.5040.1.2.27.3.1.3.5
OBJECT IDENTIFIER    

wtIpWatcherSyslog 1.3.6.1.4.1.5040.1.2.27.3.1.3.7
OBJECT IDENTIFIER    

wtIpWatcherFTP 1.3.6.1.4.1.5040.1.2.27.3.1.3.8
OBJECT IDENTIFIER    

wtIpWatcherIpList 1.3.6.1.4.1.5040.1.2.27.3.1.3.11
OBJECT IDENTIFIER    

wtIpWatcherTimeZone 1.3.6.1.4.1.5040.1.2.27.3.1.2.1
OBJECT IDENTIFIER    

wtIpWatcherTimeServer 1.3.6.1.4.1.5040.1.2.27.3.1.2.2
OBJECT IDENTIFIER    

wtIpWatcherDeviceClock 1.3.6.1.4.1.5040.1.2.27.3.1.2.3
OBJECT IDENTIFIER    

wtWebioEA2x2-24VInOut 1.3.6.1.4.1.5040.1.2.30.1
OBJECT IDENTIFIER    

wtWebioEA2x2-24VSessCntrl 1.3.6.1.4.1.5040.1.2.30.2
OBJECT IDENTIFIER    

wtWebioEA2x2-24VConfig 1.3.6.1.4.1.5040.1.2.30.3
OBJECT IDENTIFIER    

wtWebioEA2x2-24VDiag 1.3.6.1.4.1.5040.1.2.30.4
OBJECT IDENTIFIER    

wtWebioEA2x2-24VDevice 1.3.6.1.4.1.5040.1.2.30.3.1
OBJECT IDENTIFIER    

wtWebioEA2x2-24VPorts 1.3.6.1.4.1.5040.1.2.30.3.2
OBJECT IDENTIFIER    

wtWebioEA2x2-24VManufact 1.3.6.1.4.1.5040.1.2.30.3.3
OBJECT IDENTIFIER    

wtWebioEA2x2-24VText 1.3.6.1.4.1.5040.1.2.30.3.1.1
OBJECT IDENTIFIER    

wtWebioEA2x2-24VTimeDate 1.3.6.1.4.1.5040.1.2.30.3.1.2
OBJECT IDENTIFIER    

wtWebioEA2x2-24VBasic 1.3.6.1.4.1.5040.1.2.30.3.1.3
OBJECT IDENTIFIER    

wtWebioEA2x2-24VOutputMode 1.3.6.1.4.1.5040.1.2.30.3.1.4
OBJECT IDENTIFIER    

wtWebioEA2x2-24VAlarm 1.3.6.1.4.1.5040.1.2.30.3.1.5
OBJECT IDENTIFIER    

wtWebioEA2x2-24VNetwork 1.3.6.1.4.1.5040.1.2.30.3.1.3.1
OBJECT IDENTIFIER    

wtWebioEA2x2-24VHTTP 1.3.6.1.4.1.5040.1.2.30.3.1.3.2
OBJECT IDENTIFIER    

wtWebioEA2x2-24VMail 1.3.6.1.4.1.5040.1.2.30.3.1.3.3
OBJECT IDENTIFIER    

wtWebioEA2x2-24VSNMP 1.3.6.1.4.1.5040.1.2.30.3.1.3.4
OBJECT IDENTIFIER    

wtWebioEA2x2-24VUDP 1.3.6.1.4.1.5040.1.2.30.3.1.3.5
OBJECT IDENTIFIER    

wtWebioEA2x2-24VBinary 1.3.6.1.4.1.5040.1.2.30.3.1.3.6
OBJECT IDENTIFIER    

wtWebioEA2x2-24VSyslog 1.3.6.1.4.1.5040.1.2.30.3.1.3.7
OBJECT IDENTIFIER    

wtWebioEA2x2-24VFTP 1.3.6.1.4.1.5040.1.2.30.3.1.3.8
OBJECT IDENTIFIER    

wtWebioEA2x2-24VTimeZone 1.3.6.1.4.1.5040.1.2.30.3.1.2.1
OBJECT IDENTIFIER    

wtWebioEA2x2-24VTimeServer 1.3.6.1.4.1.5040.1.2.30.3.1.2.2
OBJECT IDENTIFIER    

wtWebioEA2x2-24VDeviceClock 1.3.6.1.4.1.5040.1.2.30.3.1.2.3
OBJECT IDENTIFIER    

wtWebioEA2x2ERP-24VInOut 1.3.6.1.4.1.5040.1.2.31.1
OBJECT IDENTIFIER    

wtWebioEA2x2ERP-24VSessCntrl 1.3.6.1.4.1.5040.1.2.31.2
OBJECT IDENTIFIER    

wtWebioEA2x2ERP-24VConfig 1.3.6.1.4.1.5040.1.2.31.3
OBJECT IDENTIFIER    

wtWebioEA2x2ERP-24VDiag 1.3.6.1.4.1.5040.1.2.31.4
OBJECT IDENTIFIER    

wtWebioEA2x2ERP-24VDevice 1.3.6.1.4.1.5040.1.2.31.3.1
OBJECT IDENTIFIER    

wtWebioEA2x2ERP-24VPorts 1.3.6.1.4.1.5040.1.2.31.3.2
OBJECT IDENTIFIER    

wtWebioEA2x2ERP-24VManufact 1.3.6.1.4.1.5040.1.2.31.3.3
OBJECT IDENTIFIER    

wtWebioEA2x2ERP-24VText 1.3.6.1.4.1.5040.1.2.31.3.1.1
OBJECT IDENTIFIER    

wtWebioEA2x2ERP-24VTimeDate 1.3.6.1.4.1.5040.1.2.31.3.1.2
OBJECT IDENTIFIER    

wtWebioEA2x2ERP-24VBasic 1.3.6.1.4.1.5040.1.2.31.3.1.3
OBJECT IDENTIFIER    

wtWebioEA2x2ERP-24VOutputMode 1.3.6.1.4.1.5040.1.2.31.3.1.4
OBJECT IDENTIFIER    

wtWebioEA2x2ERP-24VAlarm 1.3.6.1.4.1.5040.1.2.31.3.1.5
OBJECT IDENTIFIER    

wtWebioEA2x2ERP-24VNetwork 1.3.6.1.4.1.5040.1.2.31.3.1.3.1
OBJECT IDENTIFIER    

wtWebioEA2x2ERP-24VHTTP 1.3.6.1.4.1.5040.1.2.31.3.1.3.2
OBJECT IDENTIFIER    

wtWebioEA2x2ERP-24VMail 1.3.6.1.4.1.5040.1.2.31.3.1.3.3
OBJECT IDENTIFIER    

wtWebioEA2x2ERP-24VSNMP 1.3.6.1.4.1.5040.1.2.31.3.1.3.4
OBJECT IDENTIFIER    

wtWebioEA2x2ERP-24VUDP 1.3.6.1.4.1.5040.1.2.31.3.1.3.5
OBJECT IDENTIFIER    

wtWebioEA2x2ERP-24VBinary 1.3.6.1.4.1.5040.1.2.31.3.1.3.6
OBJECT IDENTIFIER    

wtWebioEA2x2ERP-24VSyslog 1.3.6.1.4.1.5040.1.2.31.3.1.3.7
OBJECT IDENTIFIER    

wtWebioEA2x2ERP-24VFTP 1.3.6.1.4.1.5040.1.2.31.3.1.3.8
OBJECT IDENTIFIER    

wtWebioEA2x2ERP-24VWayBack 1.3.6.1.4.1.5040.1.2.31.3.1.3.10
OBJECT IDENTIFIER    

wtWebioEA2x2ERP-24VTimeZone 1.3.6.1.4.1.5040.1.2.31.3.1.2.1
OBJECT IDENTIFIER    

wtWebioEA2x2ERP-24VTimeServer 1.3.6.1.4.1.5040.1.2.31.3.1.2.2
OBJECT IDENTIFIER    

wtWebioEA2x2ERP-24VDeviceClock 1.3.6.1.4.1.5040.1.2.31.3.1.2.3
OBJECT IDENTIFIER    

wtIpWatcher-24VInOut 1.3.6.1.4.1.5040.1.2.32.1
OBJECT IDENTIFIER    

wtIpWatcher-24VSessCntrl 1.3.6.1.4.1.5040.1.2.32.2
OBJECT IDENTIFIER    

wtIpWatcher-24VConfig 1.3.6.1.4.1.5040.1.2.32.3
OBJECT IDENTIFIER    

wtIpWatcher-24VDiag 1.3.6.1.4.1.5040.1.2.32.4
OBJECT IDENTIFIER    

wtIpWatcher-24VDevice 1.3.6.1.4.1.5040.1.2.32.3.1
OBJECT IDENTIFIER    

wtIpWatcher-24VPorts 1.3.6.1.4.1.5040.1.2.32.3.2
OBJECT IDENTIFIER    

wtIpWatcher-24VManufact 1.3.6.1.4.1.5040.1.2.32.3.3
OBJECT IDENTIFIER    

wtIpWatcher-24VText 1.3.6.1.4.1.5040.1.2.32.3.1.1
OBJECT IDENTIFIER    

wtIpWatcher-24VTimeDate 1.3.6.1.4.1.5040.1.2.32.3.1.2
OBJECT IDENTIFIER    

wtIpWatcher-24VBasic 1.3.6.1.4.1.5040.1.2.32.3.1.3
OBJECT IDENTIFIER    

wtIpWatcher-24VOutputMode 1.3.6.1.4.1.5040.1.2.32.3.1.4
OBJECT IDENTIFIER    

wtIpWatcher-24VAlarm 1.3.6.1.4.1.5040.1.2.32.3.1.5
OBJECT IDENTIFIER    

wtIpWatcher-24VNetwork 1.3.6.1.4.1.5040.1.2.32.3.1.3.1
OBJECT IDENTIFIER    

wtIpWatcher-24VHTTP 1.3.6.1.4.1.5040.1.2.32.3.1.3.2
OBJECT IDENTIFIER    

wtIpWatcher-24VMail 1.3.6.1.4.1.5040.1.2.32.3.1.3.3
OBJECT IDENTIFIER    

wtIpWatcher-24VSNMP 1.3.6.1.4.1.5040.1.2.32.3.1.3.4
OBJECT IDENTIFIER    

wtIpWatcher-24VUDP 1.3.6.1.4.1.5040.1.2.32.3.1.3.5
OBJECT IDENTIFIER    

wtIpWatcher-24VSyslog 1.3.6.1.4.1.5040.1.2.32.3.1.3.7
OBJECT IDENTIFIER    

wtIpWatcher-24VFTP 1.3.6.1.4.1.5040.1.2.32.3.1.3.8
OBJECT IDENTIFIER    

wtIpWatcher-24VIpList 1.3.6.1.4.1.5040.1.2.32.3.1.3.11
OBJECT IDENTIFIER    

wtIpWatcher-24VTimeZone 1.3.6.1.4.1.5040.1.2.32.3.1.2.1
OBJECT IDENTIFIER    

wtIpWatcher-24VTimeServer 1.3.6.1.4.1.5040.1.2.32.3.1.2.2
OBJECT IDENTIFIER    

wtIpWatcher-24VDeviceClock 1.3.6.1.4.1.5040.1.2.32.3.1.2.3
OBJECT IDENTIFIER    

wtTrapReceiver2x2InOut 1.3.6.1.4.1.5040.1.2.33.1
OBJECT IDENTIFIER    

wtTrapReceiver2x2SessCntrl 1.3.6.1.4.1.5040.1.2.33.2
OBJECT IDENTIFIER    

wtTrapReceiver2x2Config 1.3.6.1.4.1.5040.1.2.33.3
OBJECT IDENTIFIER    

wtTrapReceiver2x2Diag 1.3.6.1.4.1.5040.1.2.33.4
OBJECT IDENTIFIER    

wtTrapReceiver2x2Device 1.3.6.1.4.1.5040.1.2.33.3.1
OBJECT IDENTIFIER    

wtTrapReceiver2x2Ports 1.3.6.1.4.1.5040.1.2.33.3.2
OBJECT IDENTIFIER    

wtTrapReceiver2x2Manufact 1.3.6.1.4.1.5040.1.2.33.3.3
OBJECT IDENTIFIER    

wtTrapReceiver2x2Text 1.3.6.1.4.1.5040.1.2.33.3.1.1
OBJECT IDENTIFIER    

wtTrapReceiver2x2TimeDate 1.3.6.1.4.1.5040.1.2.33.3.1.2
OBJECT IDENTIFIER    

wtTrapReceiver2x2Basic 1.3.6.1.4.1.5040.1.2.33.3.1.3
OBJECT IDENTIFIER    

wtTrapReceiver2x2OutputMode 1.3.6.1.4.1.5040.1.2.33.3.1.4
OBJECT IDENTIFIER    

wtTrapReceiver2x2Action 1.3.6.1.4.1.5040.1.2.33.3.1.5
OBJECT IDENTIFIER    

wtTrapReceiver2x2PrepareInEvents 1.3.6.1.4.1.5040.1.2.33.3.1.6
OBJECT IDENTIFIER    

wtTrapReceiver2x2PrepareOutEvents 1.3.6.1.4.1.5040.1.2.33.3.1.7
OBJECT IDENTIFIER    

wtTrapReceiver2x2Network 1.3.6.1.4.1.5040.1.2.33.3.1.3.1
OBJECT IDENTIFIER    

wtTrapReceiver2x2HTTP 1.3.6.1.4.1.5040.1.2.33.3.1.3.2
OBJECT IDENTIFIER    

wtTrapReceiver2x2Mail 1.3.6.1.4.1.5040.1.2.33.3.1.3.3
OBJECT IDENTIFIER    

wtTrapReceiver2x2SNMP 1.3.6.1.4.1.5040.1.2.33.3.1.3.4
OBJECT IDENTIFIER    

wtTrapReceiver2x2UDP 1.3.6.1.4.1.5040.1.2.33.3.1.3.5
OBJECT IDENTIFIER    

wtTrapReceiver2x2Syslog 1.3.6.1.4.1.5040.1.2.33.3.1.3.7
OBJECT IDENTIFIER    

wtTrapReceiver2x2FTP 1.3.6.1.4.1.5040.1.2.33.3.1.3.8
OBJECT IDENTIFIER    

wtTrapReceiver2x2TimeZone 1.3.6.1.4.1.5040.1.2.33.3.1.2.1
OBJECT IDENTIFIER    

wtTrapReceiver2x2TimeServer 1.3.6.1.4.1.5040.1.2.33.3.1.2.2
OBJECT IDENTIFIER    

wtTrapReceiver2x2DeviceClock 1.3.6.1.4.1.5040.1.2.33.3.1.2.3
OBJECT IDENTIFIER    

wtTrapReceiver2x2WatchList 1.3.6.1.4.1.5040.1.2.33.3.1.6.1
OBJECT IDENTIFIER    

wtTrapReceiver2x2InEvSystemTimer 1.3.6.1.4.1.5040.1.2.33.3.1.6.2
OBJECT IDENTIFIER    

wtTrapReceiver2x2InEvButtons 1.3.6.1.4.1.5040.1.2.33.3.1.6.3
OBJECT IDENTIFIER    

wtTrapReceiver2x2InEvInputs 1.3.6.1.4.1.5040.1.2.33.3.1.6.4
OBJECT IDENTIFIER    

wtTrapReceiver2x2OutEvOutputs 1.3.6.1.4.1.5040.1.2.33.3.1.7.1
OBJECT IDENTIFIER    

wtWebioEA2x2Inputs 1.3.6.1.4.1.5040.1.2.13.1.1
Number of idependent inputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtWebioEA2x2Outputs 1.3.6.1.4.1.5040.1.2.13.1.2
Number of idependent outputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtWebioEA2x2InputTable 1.3.6.1.4.1.5040.1.2.13.1.3
List of input indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2InputEntry

wtWebioEA2x2InputEntry 1.3.6.1.4.1.5040.1.2.13.1.3.1
Number of the inputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2InputEntry  

wtWebioEA2x2InputNo 1.3.6.1.4.1.5040.1.2.13.1.3.1.1
Index numbers of the inputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebioEA2x2InputCounter 1.3.6.1.4.1.5040.1.2.13.1.3.1.2
Value of the input counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebioEA2x2InputCounterClear 1.3.6.1.4.1.5040.1.2.13.1.3.1.3
Clears the input counter after returning its value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2InputState 1.3.6.1.4.1.5040.1.2.13.1.3.1.4
Value of a single input bit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtWebioEA2x2InputState-OFF(0), wtWebioEA2x2InputState-ON(1)  

wtWebioEA2x2InputValue 1.3.6.1.4.1.5040.1.2.13.1.4
This variable is used to read the inputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital outputs 0-1
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2OutputTable 1.3.6.1.4.1.5040.1.2.13.1.5
List of output indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2OutputEntry

wtWebioEA2x2OutputEntry 1.3.6.1.4.1.5040.1.2.13.1.5.1
Number of the outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2OutputEntry  

wtWebioEA2x2OutputNo 1.3.6.1.4.1.5040.1.2.13.1.5.1.1
Output number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebioEA2x2OutputState 1.3.6.1.4.1.5040.1.2.13.1.5.1.2
Value of a single output bit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA2x2OutputState-OFF(0), wtWebioEA2x2OutputState-ON(1)  

wtWebioEA2x2OutputValue 1.3.6.1.4.1.5040.1.2.13.1.6
This variable is used to read and write the outputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital outputs 0-1 Bit 2-7: ungenutzt
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2SetOutput 1.3.6.1.4.1.5040.1.2.13.1.7
This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first two OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital outputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital outputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

wtWebioEA2x2SessCntrlPassword 1.3.6.1.4.1.5040.1.2.13.2.1
Entering this password opens a session which is ended by writing a 1 to wtWebioEA2x2SessCntrlLogout. When read this variable provides a string of length zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2SessCntrlConfigMode 1.3.6.1.4.1.5040.1.2.13.2.2
When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtWebioEA2x2SessCntrl-NoSession(0), wtWebioEA2x2SessCntrl-Session(1)  

wtWebioEA2x2SessCntrlLogout 1.3.6.1.4.1.5040.1.2.13.2.3
If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2SessCntrlAdminPassword 1.3.6.1.4.1.5040.1.2.13.2.4
This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2SessCntrlConfigPassword 1.3.6.1.4.1.5040.1.2.13.2.5
This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2DeviceName 1.3.6.1.4.1.5040.1.2.13.3.1.1.1
Name of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2DeviceText 1.3.6.1.4.1.5040.1.2.13.3.1.1.2
Description of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2DeviceLocation 1.3.6.1.4.1.5040.1.2.13.3.1.1.3
Description of the location of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2DeviceContact 1.3.6.1.4.1.5040.1.2.13.3.1.1.4
Contact address of the system operator of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2TzOffsetHrs 1.3.6.1.4.1.5040.1.2.13.3.1.2.1.1
Offset hours for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2TzOffsetMin 1.3.6.1.4.1.5040.1.2.13.3.1.2.1.2
Offset minutes for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2TzEnable 1.3.6.1.4.1.5040.1.2.13.3.1.2.1.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2StTzOffsetHrs 1.3.6.1.4.1.5040.1.2.13.3.1.2.1.4
Offset hours of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2StTzOffsetMin 1.3.6.1.4.1.5040.1.2.13.3.1.2.1.5
Offset minutes of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2StTzEnable 1.3.6.1.4.1.5040.1.2.13.3.1.2.1.6
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2StTzStartMonth 1.3.6.1.4.1.5040.1.2.13.3.1.2.1.7
Month in which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA2x2StartMonth-January(1), wtWebioEA2x2StartMonth-February(2), wtWebioEA2x2StartMonth-March(3), wtWebioEA2x2StartMonth-April(4), wtWebioEA2x2StartMonth-May(5), wtWebioEA2x2StartMonth-June(6), wtWebioEA2x2StartMonth-July(7), wtWebioEA2x2StartMonth-August(8), wtWebioEA2x2StartMonth-September(9), wtWebioEA2x2StartMonth-October(10), wtWebioEA2x2StartMonth-November(11), wtWebioEA2x2StartMonth-December(12)  

wtWebioEA2x2StTzStartMode 1.3.6.1.4.1.5040.1.2.13.3.1.2.1.8
Mode of the day of the week for which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA2x2StartMode-first(1), wtWebioEA2x2StartMode-second(2), wtWebioEA2x2StartMode-third(3), wtWebioEA2x2StartMode-fourth(4), wtWebioEA2x2StartMode-last(5)  

wtWebioEA2x2StTzStartWday 1.3.6.1.4.1.5040.1.2.13.3.1.2.1.9
Day of the week on which the change is made from winter time to summer time
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA2x2StartWday-Sunday(1), wtWebioEA2x2StartWday-Monday(2), wtWebioEA2x2StartWday-Tuesday(3), wtWebioEA2x2StartWday-Thursday(4), wtWebioEA2x2StartWday-Wednesday(5), wtWebioEA2x2StartWday-Friday(6), wtWebioEA2x2StartWday-Saturday(7)  

wtWebioEA2x2StTzStartHrs 1.3.6.1.4.1.5040.1.2.13.3.1.2.1.10
Hour in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2StTzStartMin 1.3.6.1.4.1.5040.1.2.13.3.1.2.1.11
Minute in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2StTzStopMonth 1.3.6.1.4.1.5040.1.2.13.3.1.2.1.12
Month in which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA2x2StopMonth-January(1), wtWebioEA2x2StopMonth-February(2), wtWebioEA2x2StopMonth-March(3), wtWebioEA2x2StopMonth-April(4), wtWebioEA2x2StopMonth-May(5), wtWebioEA2x2StopMonth-June(6), wtWebioEA2x2StopMonth-July(7), wtWebioEA2x2StopMonth-August(8), wtWebioEA2x2StopMonth-September(9), wtWebioEA2x2StopMonth-October(10), wtWebioEA2x2StopMonth-November(11), wtWebioEA2x2StopMonth-December(12)  

wtWebioEA2x2StTzStopMode 1.3.6.1.4.1.5040.1.2.13.3.1.2.1.13
Mode of the week day on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA2x2StopMode-first(1), wtWebioEA2x2StopMode-second(2), wtWebioEA2x2StopMode-third(3), wtWebioEA2x2StopMode-fourth(4), wtWebioEA2x2StopMode-last(5)  

wtWebioEA2x2StTzStopWday 1.3.6.1.4.1.5040.1.2.13.3.1.2.1.14
Day of the week on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA2x2StopWday-Sunday(1), wtWebioEA2x2StopWday-Monday(2), wtWebioEA2x2StopWday-Tuesday(3), wtWebioEA2x2StopWday-Thursday(4), wtWebioEA2x2StopWday-Wednesday(5), wtWebioEA2x2StopWday-Friday(6), wtWebioEA2x2StopWday-Saturday(7)  

wtWebioEA2x2StTzStopHrs 1.3.6.1.4.1.5040.1.2.13.3.1.2.1.15
Hour at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2StTzStopMin 1.3.6.1.4.1.5040.1.2.13.3.1.2.1.16
Minute at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2TimeServer1 1.3.6.1.4.1.5040.1.2.13.3.1.2.2.1
IP address or name of the 1st time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2TimeServer2 1.3.6.1.4.1.5040.1.2.13.3.1.2.2.2
IP address or name of the 2nd time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2TsEnable 1.3.6.1.4.1.5040.1.2.13.3.1.2.2.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2TsSyncTime 1.3.6.1.4.1.5040.1.2.13.3.1.2.2.4
Daily synchronisation time with the time server (hour: 0-23).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ClockHrs 1.3.6.1.4.1.5040.1.2.13.3.1.2.3.1
Clock hours taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..23  

wtWebioEA2x2ClockMin 1.3.6.1.4.1.5040.1.2.13.3.1.2.3.2
Clock minutes taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..59  

wtWebioEA2x2ClockDay 1.3.6.1.4.1.5040.1.2.13.3.1.2.3.3
Date: Day of the month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..31  

wtWebioEA2x2ClockMonth 1.3.6.1.4.1.5040.1.2.13.3.1.2.3.4
Date: Month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA2x2ClockMonth-January(1), wtWebioEA2x2ClockMonth-February(2), wtWebioEA2x2ClockMonth-March(3), wtWebioEA2x2ClockMonth-April(4), wtWebioEA2x2ClockMonth-May(5), wtWebioEA2x2ClockMonth-June(6), wtWebioEA2x2ClockMonth-July(7), wtWebioEA2x2ClockMonth-August(8), wtWebioEA2x2ClockMonth-September(9), wtWebioEA2x2ClockMonth-October(10), wtWebioEA2x2ClockMonth-November(11), wtWebioEA2x2ClockMonth-December(12)  

wtWebioEA2x2ClockYear 1.3.6.1.4.1.5040.1.2.13.3.1.2.3.5
Date: Year, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA2x2IpAddress 1.3.6.1.4.1.5040.1.2.13.3.1.3.1.1
IP address of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioEA2x2SubnetMask 1.3.6.1.4.1.5040.1.2.13.3.1.3.1.2
Subnet mask of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioEA2x2Gateway 1.3.6.1.4.1.5040.1.2.13.3.1.3.1.3
Gateway of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioEA2x2DnsServer1 1.3.6.1.4.1.5040.1.2.13.3.1.3.1.4
IP address of the 1st DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2DnsServer2 1.3.6.1.4.1.5040.1.2.13.3.1.3.1.5
IP address of the 2nd DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2AddConfig 1.3.6.1.4.1.5040.1.2.13.3.1.3.1.6
Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP enable Bit 0: BOOTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2Startup 1.3.6.1.4.1.5040.1.2.13.3.1.3.2.1
Binary coded start page, more than one page must not be selected: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2: user.htm Bit 1: home.htm Bit 0: index.htm
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2GetHeaderEnable 1.3.6.1.4.1.5040.1.2.13.3.1.3.2.2
If bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device (Header) or a HTTP header (HTTP): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2-7: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2HttpInputTrigger 1.3.6.1.4.1.5040.1.2.13.3.1.3.2.3
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2HttpPort 1.3.6.1.4.1.5040.1.2.13.3.1.3.2.4
Definition of the standard HTML port (Default: 80).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65534  

wtWebioEA2x2MailAdName 1.3.6.1.4.1.5040.1.2.13.3.1.3.3.1
Device name for mail administration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2MailReply 1.3.6.1.4.1.5040.1.2.13.3.1.3.3.2
Reply address for the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2MailServer 1.3.6.1.4.1.5040.1.2.13.3.1.3.3.3
Name or IP address of the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2MailEnable 1.3.6.1.4.1.5040.1.2.13.3.1.3.3.4
Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2MailAuthentication 1.3.6.1.4.1.5040.1.2.13.3.1.3.3.5
Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2MailAuthUser 1.3.6.1.4.1.5040.1.2.13.3.1.3.3.6
Name of the user to be authenticated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2MailAuthPassword 1.3.6.1.4.1.5040.1.2.13.3.1.3.3.7
Authentication password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2MailPop3Server 1.3.6.1.4.1.5040.1.2.13.3.1.3.3.8
Name or Ip-address of the POP3 Servers.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2SnmpEnable 1.3.6.1.4.1.5040.1.2.13.3.1.3.4.1
Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2SnmpCommunityStringRead 1.3.6.1.4.1.5040.1.2.13.3.1.3.4.2
Community string read only
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2SnmpCommunityStringReadWrite 1.3.6.1.4.1.5040.1.2.13.3.1.3.4.3
Community string read / write
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2SnmpSystemTrapManagerIP 1.3.6.1.4.1.5040.1.2.13.3.1.3.4.4
Name or IP address of the TCP server which accepts the system trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2SnmpSystemTrapEnable 1.3.6.1.4.1.5040.1.2.13.3.1.3.4.5
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag messages Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2UdpAdminPort 1.3.6.1.4.1.5040.1.2.13.3.1.3.5.1
Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2UdpEnable 1.3.6.1.4.1.5040.1.2.13.3.1.3.5.2
Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2UdpRemotePort 1.3.6.1.4.1.5040.1.2.13.3.1.3.5.3
Udp remote port setting. If this value is set to zero, the source port read from a request will be used as destination port for the answer. A non zero value forced the destination port to this value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2BinaryModeCount 1.3.6.1.4.1.5040.1.2.13.3.1.3.6.1
Number of independent binary channels.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtWebioEA2x2BinaryIfTable 1.3.6.1.4.1.5040.1.2.13.3.1.3.6.2
Table of indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2BinaryIfEntry

wtWebioEA2x2BinaryIfEntry 1.3.6.1.4.1.5040.1.2.13.3.1.3.6.2.1
Indices of the binary channels.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2BinaryIfEntry  

wtWebioEA2x2BinaryModeNo 1.3.6.1.4.1.5040.1.2.13.3.1.3.6.2.1.1
Number of the binary channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtWebioEA2x2BinaryTable 1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3
Table of properties of the binary mode.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2BinaryEntry

wtWebioEA2x2BinaryEntry 1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1
Binary properties.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2BinaryEntry  

wtWebioEA2x2BinaryOperationMode 1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.1
Selection of the operation mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : UDP Peer Bit 1 : TCP Client Bit 0 : TCP Server
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2BinaryTcpServerLocalPort 1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.2
Local TCP port for data exchange in this server mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2BinaryTcpServerInputTrigger 1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.3
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2BinaryTcpServerApplicationMode 1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.4
Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 4-7: unused Bit 3 : OPC Device Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2BinaryTcpClientLocalPort 1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.5
Local TCP port for data exchange in this client mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2BinaryTcpClientServerPort 1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.6
Port number of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server port to zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2BinaryTcpClientServerIpAddr 1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.7
Ip address of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server IP address to 0.0.0.0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2BinaryTcpClientServerPassword 1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.8
Building a connection may be protected by the administrator password of the server. Enter the server password to establish the connection, if a server administrator password exists.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2BinaryTcpClientInactivity 1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.9
Connection timeout in 100ms. If no data are exchanged within the specified time, the device closes the connection to the server. The value 0 deactivates the timer. Using the Box2Box mode this function is disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2BinaryTcpClientInputTrigger 1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.10
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2BinaryTcpClientInterval 1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.11
Configurable interval with a 100ms base, in which the Webio device sends data to the configured application. A interval of zero stopps the periodical sending.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA2x2BinaryTcpClientApplicationMode 1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.12
Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2BinaryUdpPeerLocalPort 1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.13
Local UDP port for data exchange in this peer to peer mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2BinaryUdpPeerRemotePort 1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.14
Port number of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote port to zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2BinaryUdpPeerRemoteIpAddr 1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.15
Ip address of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote device IP address to 0.0.0.0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2BinaryUdpPeerInputTrigger 1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.16
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2BinaryUdpPeerInterval 1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.17
Configurable interval with a 100ms base, in which the Webio device sends data to the configured remote device. A interval of zero stopps the periodical sending.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA2x2BinaryUdpPeerApplicationMode 1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.18
Selection of the application mode: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2BinaryConnectedPort 1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.19
Port number of the remote device, after connection has been established. In case of no connection or missing port informations a zero will be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2BinaryConnectedIpAddr 1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.20
IP address of the remote device, after connection has been established. In case of no connection or missing port informations 0.0.0.0 will be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

wtWebioEA2x2BinaryTcpServerClientHttpPort 1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.21
HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs status informations will be send to this port. Not used at mode Compatible 50xxx.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2BinaryTcpClientServerHttpPort 1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.22
HTTP port number of the remote device at TCP Client Mode. In the operating mode Box2Box connection status informations will be exchanged through this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2SyslogServerIP 1.3.6.1.4.1.5040.1.2.13.3.1.3.7.1
Name or IP address of the Syslog server, which accepts the Syslog messgaes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2SyslogServerPort 1.3.6.1.4.1.5040.1.2.13.3.1.3.7.2
Portnumber of the Syslog servers, default 514.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2SyslogSystemMessagesEnable 1.3.6.1.4.1.5040.1.2.13.3.1.3.7.3
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2SyslogEnable 1.3.6.1.4.1.5040.1.2.13.3.1.3.7.4
Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2FTPServerIP 1.3.6.1.4.1.5040.1.2.13.3.1.3.8.1
Name or IP address of the FTP server, which accepts the FTP messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2FTPServerControlPort 1.3.6.1.4.1.5040.1.2.13.3.1.3.8.2
Portnumber of the control port of the FTP server, default 21.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2FTPUserName 1.3.6.1.4.1.5040.1.2.13.3.1.3.8.3
FTP Loggin: user name.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2FTPPassword 1.3.6.1.4.1.5040.1.2.13.3.1.3.8.4
FTP Loggin: user password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2FTPAccount 1.3.6.1.4.1.5040.1.2.13.3.1.3.8.5
FTP Loggin: name of account.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2FTPOption 1.3.6.1.4.1.5040.1.2.13.3.1.3.8.6
Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2FTPEnable 1.3.6.1.4.1.5040.1.2.13.3.1.3.8.7
Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2OutputModeTable 1.3.6.1.4.1.5040.1.2.13.3.1.4.1
Table of output mode configurations dependent on the output indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2OutputModeEntry

wtWebioEA2x2OutputModeEntry 1.3.6.1.4.1.5040.1.2.13.3.1.4.1.1
Output mode configurations of the individual outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2OutputModeEntry  

wtWebioEA2x2OutputModeBit 1.3.6.1.4.1.5040.1.2.13.3.1.4.1.1.1
This binary coded output mode defines the individual operation mode for any output. More than one mode must not be selected. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 6-7: unused Bit 5 : Logic Bit 4 : Binary 2 Bit 3 : Binary 1 Bit 2 : SNMP Bit 1 : UDP ASCII Bit 0 : HTTP
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2SafetyTimeout 1.3.6.1.4.1.5040.1.2.13.3.1.4.2
After this period of time (multiple of 100ms) without receiving data outputs switch to their Safety States. For each output a independend safety state could be defined.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA2x2LoadControlEnable 1.3.6.1.4.1.5040.1.2.13.3.1.4.3
Here the function of automatic load control can be enabled. All output were tested in pairs (0-1). If an error occours at one output, both output of an pair will be switched of. For a properly function of the load control each output of a pair have to has a load. If there is no existing load, a pull down resistor can be used. Outputs with no load are automaticly detected and not part of the control function. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Load Control enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2AlarmCount 1.3.6.1.4.1.5040.1.2.13.3.1.5.1
Number of independent alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

wtWebioEA2x2AlarmIfTable 1.3.6.1.4.1.5040.1.2.13.3.1.5.2
List of alarm indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2AlarmIfEntry

wtWebioEA2x2AlarmIfEntry 1.3.6.1.4.1.5040.1.2.13.3.1.5.2.1
Numbers of the alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2AlarmIfEntry  

wtWebioEA2x2AlarmNo 1.3.6.1.4.1.5040.1.2.13.3.1.5.2.1.1
Numbers of the alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

wtWebioEA2x2AlarmTable 1.3.6.1.4.1.5040.1.2.13.3.1.5.3
List of settings depending on the alarm number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2AlarmEntry

wtWebioEA2x2AlarmEntry 1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1
Alarm parameters of the individual alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2AlarmEntry  

wtWebioEA2x2AlarmInputTrigger 1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.1
This variable allows setting of individual input trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the inputs are to be considered (corresponding bit = 1) and which inputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital inputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital inputs 0-1 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change of the corresponding input bit. Settings in OCTET 5-9 are then unused: OCTET 9: unused OCTET 10: unused OCTET 11: unused OCTET 12, Bit 0-1: ANY bits of digital inputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(12)  

wtWebioEA2x2AlarmOutputTrigger 1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.2
This variable allows setting of individual output trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be considered (corresponding bit = 1) and which outputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital outputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital outputs 0-1 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change of the corresponding output bit. Settings in OCTET 5-9 are then unused: OCTET 9: unused OCTET 10: unused OCTET 11: unused OCTET 12, Bit 0-1: ANY bits of digital outputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(12)  

wtWebioEA2x2AlarmSystemTrigger 1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.3
Binary coded trigger conditions: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Warm Start Bit 2 : Cold Start Bit 1 : Timer Bit 0 : Load Control
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2AlarmMaxCounterValue 1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.4
This variable configures a max. counter value. If an input counter value exceeds this max. value, the corresponding alarm is triggered. Input counters with its mask bit unset in wtWebioEA2x2AlarmInputTrigger are not considered.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2AlarmInterval 1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.5
Send interval for alarm messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2AlarmEnable 1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.6
Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: UDP enable Bit 3: Send inputs to pending TCP connections Bit 4: TCP Client enable Bit 5: Syslog Messages enable Bit 6-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2AlarmMailAddr 1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.7
E-Mail address for sending the alarm mail to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2AlarmMailSubject 1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.8
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2AlarmMailText 1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.9
Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2AlarmSnmpManagerIP 1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.10
IP address of the SNMP Manager to which the Webio device should send SNMP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2AlarmSnmpTrapText 1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.11
This text appears in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2AlarmUdpIpAddr 1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.12
IP address of the UDP listener to which the Webio device should send UDP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2AlarmUdpPort 1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.13
Port number of the UDP listener to which the Webio device should send UDP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2AlarmUdpText 1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.14
This text appears in the UDP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2AlarmTcpIpAddr 1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.15
IP address of the TCP listener to which the Webio device should send TCP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2AlarmTcpPort 1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.16
Port number of the TCP listener to which the Webio device should send TCP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2AlarmTcpText 1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.17
This text appears in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2AlarmSyslogIpAddr 1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.18
IP address of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2AlarmSyslogPort 1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.19
Port number of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2AlarmSyslogText 1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.20
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2AlarmFtpDataPort 1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.21
Local data port: 1..65535 or AUTO: the next free port will be assigned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2AlarmFtpFileName 1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.22
Name of the file including path informations.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2AlarmFtpText 1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.23
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2AlarmFtpOption 1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.24
Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2AlarmTimerCron 1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.25
This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2AlarmMailReleaseSubject 1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.26
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2AlarmMailReleaseText 1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.27
Release Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2AlarmSnmpTrapReleaseText 1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.28
This text appears in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2AlarmUdpReleaseText 1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.29
This text appears in the UDP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2AlarmTcpReleaseText 1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.30
This text appears in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2AlarmSyslogReleaseText 1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.31
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2AlarmFtpReleaseText 1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.32
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2LoadControlView 1.3.6.1.4.1.5040.1.2.13.3.1.5.4
Here the result of automatic load control can be read. All output were tested in pairs (0-1). If an error occours at one output, both output of an pair will be switched of. For a properly function of the load control each output of a pair have to has a load. If there is no existing load, a pull down resistor can be used. Outputs with no load are automaticly detected and not part of the control function. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0-1: outputs 0-1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2LCShutDownView 1.3.6.1.4.1.5040.1.2.13.3.1.5.5
Here the result of the automatic load control shut down can be read. All outputs remain switched of, until a zero is written into this variable. But previously all loads should be inspected. High current (short circuit), a broken supply line or a defect load (i.e. lamp) may be a shut down reason. If no load is detected, the load control unit suspend automaticly the control of the corresponding output pair. All controlled output could be identified reading the variable wtWebioEA2x2LoadControlEnable. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an ouput. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0-1: outputs 0-1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2InputPortTable 1.3.6.1.4.1.5040.1.2.13.3.2.1
List of settings depending on the input number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2InputPortEntry

wtWebioEA2x2InputPortEntry 1.3.6.1.4.1.5040.1.2.13.3.2.1.1
Input parameter for the individual inputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2InputPortEntry  

wtWebioEA2x2PortInputName 1.3.6.1.4.1.5040.1.2.13.3.2.1.1.1
Name of the input.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2PortInputText 1.3.6.1.4.1.5040.1.2.13.3.2.1.1.2
Description of the input.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2PortInputMode 1.3.6.1.4.1.5040.1.2.13.3.2.1.1.3
Binary coded modes: Selecting short pulse detection enable by setting the corresponding bit to 1 enables interrupt support for counting. Only positive edges are accepted as trigger source. The maximum counting frequenz equals 2000 Hz. This mode is available for inputs 0-3 only. Selecting counter clear on read by setting the corresponding bit to 1 enables the corresponding counter to be cleared automatically every time it is read, except HTTP reading with user rights. The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. Selection for input 0-1: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Bidirectional counter enable Bit 2 : Counter clear on read Bit 1 : Change detection enable (default) Bit 0 : Short Pulse detection enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2PortInputFilter 1.3.6.1.4.1.5040.1.2.13.3.2.1.1.4
Pulses with a duration shorter than here specified (duration in 1/1000 sec), are ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2PortInputBicountPulsePolarity 1.3.6.1.4.1.5040.1.2.13.3.2.1.1.5
This value defines the polarity of the input pulse. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2PortInputBicountInactivTimeout 1.3.6.1.4.1.5040.1.2.13.3.2.1.1.6
Pulse chains with a duration shorter than here specified (in 1/10 sek), are ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2OutputPortTable 1.3.6.1.4.1.5040.1.2.13.3.2.2
List of settings depending on the output number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2OutputPortEntry

wtWebioEA2x2OutputPortEntry 1.3.6.1.4.1.5040.1.2.13.3.2.2.1
Output parameters of the individual outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2OutputPortEntry  

wtWebioEA2x2PortOutputName 1.3.6.1.4.1.5040.1.2.13.3.2.2.1.1
Name of the output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2PortOutputText 1.3.6.1.4.1.5040.1.2.13.3.2.2.1.2
Description of the output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2PortOutputGroupMode 1.3.6.1.4.1.5040.1.2.13.3.2.2.1.3
It is possible to connect outputs together to increase the output current. This could be done by connecting 2 or 4 outputs in a group together. All bits of such a group has to be set all together in the same way. This variable configures this group scheme. If one ouput bit of a group is set, all other output bits of the same group will be set in the same manner. More than one configuration must not be selected. Selection for ouputs 0-1: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: Bit 0 : ouputs 0,1 disconnected (default) Bit 1 : ouputs 0+1 connected
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2PortOutputSafetyState 1.3.6.1.4.1.5040.1.2.13.3.2.2.1.4
This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 1-7: unused Bit 0 : Mask for digital output OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs to be changed should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 1-7: unused Bit 0 : Level of digital output
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2PortLogicInputMask 1.3.6.1.4.1.5040.1.2.13.3.2.2.1.5
Selecting one of these inputs by setting the corresponding bit to 1 enables the logic function for the output identified by the index within this table. The calculation take place in 4 steps: 1. Selecting inputs (wtWebioEA2x2PortLogicInputMask) 2. Inverting inputs if necessary (wtWebioEA2x2PortLogicInputInverter) 3. Logical combination (wtWebioEA2x2PortLogicFunction) 4. Inverting the result if necessary (wtWebioEA2x2PortLogicOutputInverter) OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0-1 : inputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2PortLogicInputInverter 1.3.6.1.4.1.5040.1.2.13.3.2.2.1.6
Every input bit selected here will be inverted. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0-1 : inputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2PortLogicFunction 1.3.6.1.4.1.5040.1.2.13.3.2.2.1.7
This determines the logic function. No more than one function may be selected. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : logic function OR (default) Bit 1 : logic function AND Bit 2-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2PortLogicOutputInverter 1.3.6.1.4.1.5040.1.2.13.3.2.2.1.8
The logical operation result could be inverteted by setting the corresponding bit to 1. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : Output Inverter enable Bit 1-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2PortPulseDuration 1.3.6.1.4.1.5040.1.2.13.3.2.2.1.9
Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2PortPulsePolarity 1.3.6.1.4.1.5040.1.2.13.3.2.2.1.10
This value defines the polarity of the output pulse, if wtWebioEA2x2PortPulseDuration is not set to zero. After the pulse is finished, the output switches back to the opposite state. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2MfName 1.3.6.1.4.1.5040.1.2.13.3.3.1
Manufacturer company name
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2MfAddr 1.3.6.1.4.1.5040.1.2.13.3.3.2
Manufacturer address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2MfHotline 1.3.6.1.4.1.5040.1.2.13.3.3.3
Manufacturer hotline.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2MfInternet 1.3.6.1.4.1.5040.1.2.13.3.3.4
Manufacturer Internet address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2MfDeviceTyp 1.3.6.1.4.1.5040.1.2.13.3.3.5
Manufacturer device name (model number).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2DiagErrorCount 1.3.6.1.4.1.5040.1.2.13.4.1
Number of entries in the error memory.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2DiagBinaryError 1.3.6.1.4.1.5040.1.2.13.4.2
Error causes coded bit-by-bit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2DiagErrorIndex 1.3.6.1.4.1.5040.1.2.13.4.3
The value of this variable is used as an index to read an error massege from wtWebioEA2x2DiagErrorMessage. Errors are numbered from 1 to wtWebioEA2x2DiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebioEA2x2DiagErrorMessage.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2DiagErrorMessage 1.3.6.1.4.1.5040.1.2.13.4.4
Using wtWebioEA2x2DiagErrorIndex as an index, the appropriate message is available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2DiagErrorClear 1.3.6.1.4.1.5040.1.2.13.4.5
Writing 1 into this variable clears all diagnosis messages.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2Alert1 41
This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2Alert2 42
This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2Alert3 43
This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2Alert4 44
This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2Alert5 45
This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2Alert6 46
This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2Alert7 47
This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2Alert8 48
This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2Alert9 49
This SNMP trap is generated when Alarm 9 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2Alert10 50
This SNMP trap is generated when Alarm 10 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2Alert11 51
This SNMP trap is generated when Alarm 11 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2Alert12 52
This SNMP trap is generated when Alarm 12 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2Alert13 71
This SNMP trap is generated when Alarm 1 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2Alert14 72
This SNMP trap is generated when Alarm 2 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2Alert15 73
This SNMP trap is generated when Alarm 3 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2Alert16 74
This SNMP trap is generated when Alarm 4 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2Alert17 75
This SNMP trap is generated when Alarm 5 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2Alert18 76
This SNMP trap is generated when Alarm 6 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2Alert19 77
This SNMP trap is generated when Alarm 7 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2Alert20 78
This SNMP trap is generated when Alarm 8 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2Alert21 79
This SNMP trap is generated when Alarm 9 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2Alert22 80
This SNMP trap is generated when Alarm 10 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2Alert23 81
This SNMP trap is generated when Alarm 11 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2Alert24 82
This SNMP trap is generated when Alarm 12 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2AlertDiag 110
This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x12Inputs 1.3.6.1.4.1.5040.1.2.4.1.1
Number of idependent inputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..12  

wtWebioEA12x12Outputs 1.3.6.1.4.1.5040.1.2.4.1.2
Number of idependent outputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..12  

wtWebioEA12x12InputTable 1.3.6.1.4.1.5040.1.2.4.1.3
List of input indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA12x12InputEntry

wtWebioEA12x12InputEntry 1.3.6.1.4.1.5040.1.2.4.1.3.1
Number of the inputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA12x12InputEntry  

wtWebioEA12x12InputNo 1.3.6.1.4.1.5040.1.2.4.1.3.1.1
Index numbers of the inputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebioEA12x12InputCounter 1.3.6.1.4.1.5040.1.2.4.1.3.1.2
Value of the input counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebioEA12x12InputCounterClear 1.3.6.1.4.1.5040.1.2.4.1.3.1.3
Clears the input counter after returning its value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x12InputState 1.3.6.1.4.1.5040.1.2.4.1.3.1.4
Value of a single input bit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtWebioEA12x12InputState-OFF(0), wtWebioEA12x12InputState-ON(1)  

wtWebioEA12x12InputValue 1.3.6.1.4.1.5040.1.2.4.1.4
This variable is used to read the inputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, Bit 0-3: Digital outputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Digital outputs 0-7
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x12OutputTable 1.3.6.1.4.1.5040.1.2.4.1.5
List of output indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA12x12OutputEntry

wtWebioEA12x12OutputEntry 1.3.6.1.4.1.5040.1.2.4.1.5.1
Number of the outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA12x12OutputEntry  

wtWebioEA12x12OutputNo 1.3.6.1.4.1.5040.1.2.4.1.5.1.1
Output number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebioEA12x12OutputState 1.3.6.1.4.1.5040.1.2.4.1.5.1.2
Value of a single output bit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA12x12OutputState-OFF(0), wtWebioEA12x12OutputState-ON(1)  

wtWebioEA12x12OutputValue 1.3.6.1.4.1.5040.1.2.4.1.6
This variable is used to read and write the outputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, Bit 0-3: Digital outputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Digital outputs 0-7
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x12SetOutput 1.3.6.1.4.1.5040.1.2.4.1.7
This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first two OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3, Bit 0-3: Mask for digital outputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Mask for digital outputs 0-7 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7, Bit 0-3: Level of digital outputs 8-11 Bit 4-7: unused OCTET 8, Bit 0-7: Level of digital outputs 0-7
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

wtWebioEA12x12SessCntrlPassword 1.3.6.1.4.1.5040.1.2.4.2.1
Entering this password opens a session which is ended by writing a 1 to wtWebioEA12x12SessCntrlLogout. When read this variable provides a string of length zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12SessCntrlConfigMode 1.3.6.1.4.1.5040.1.2.4.2.2
When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtWebioEA12x12SessCntrl-NoSession(0), wtWebioEA12x12SessCntrl-Session(1)  

wtWebioEA12x12SessCntrlLogout 1.3.6.1.4.1.5040.1.2.4.2.3
If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x12SessCntrlAdminPassword 1.3.6.1.4.1.5040.1.2.4.2.4
This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12SessCntrlConfigPassword 1.3.6.1.4.1.5040.1.2.4.2.5
This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12DeviceName 1.3.6.1.4.1.5040.1.2.4.3.1.1.1
Name of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12DeviceText 1.3.6.1.4.1.5040.1.2.4.3.1.1.2
Description of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12DeviceLocation 1.3.6.1.4.1.5040.1.2.4.3.1.1.3
Description of the location of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12DeviceContact 1.3.6.1.4.1.5040.1.2.4.3.1.1.4
Contact address of the system operator of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12TzOffsetHrs 1.3.6.1.4.1.5040.1.2.4.3.1.2.1.1
Offset hours for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x12TzOffsetMin 1.3.6.1.4.1.5040.1.2.4.3.1.2.1.2
Offset minutes for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x12TzEnable 1.3.6.1.4.1.5040.1.2.4.3.1.2.1.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x12StTzOffsetHrs 1.3.6.1.4.1.5040.1.2.4.3.1.2.1.4
Offset hours of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x12StTzOffsetMin 1.3.6.1.4.1.5040.1.2.4.3.1.2.1.5
Offset minutes of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x12StTzEnable 1.3.6.1.4.1.5040.1.2.4.3.1.2.1.6
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x12StTzStartMonth 1.3.6.1.4.1.5040.1.2.4.3.1.2.1.7
Month in which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA12x12StartMonth-January(1), wtWebioEA12x12StartMonth-February(2), wtWebioEA12x12StartMonth-March(3), wtWebioEA12x12StartMonth-April(4), wtWebioEA12x12StartMonth-May(5), wtWebioEA12x12StartMonth-June(6), wtWebioEA12x12StartMonth-July(7), wtWebioEA12x12StartMonth-August(8), wtWebioEA12x12StartMonth-September(9), wtWebioEA12x12StartMonth-October(10), wtWebioEA12x12StartMonth-November(11), wtWebioEA12x12StartMonth-December(12)  

wtWebioEA12x12StTzStartMode 1.3.6.1.4.1.5040.1.2.4.3.1.2.1.8
Mode of the day of the week for which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA12x12StartMode-first(1), wtWebioEA12x12StartMode-second(2), wtWebioEA12x12StartMode-third(3), wtWebioEA12x12StartMode-fourth(4), wtWebioEA12x12StartMode-last(5)  

wtWebioEA12x12StTzStartWday 1.3.6.1.4.1.5040.1.2.4.3.1.2.1.9
Day of the week on which the change is made from winter time to summer time
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA12x12StartWday-Sunday(1), wtWebioEA12x12StartWday-Monday(2), wtWebioEA12x12StartWday-Tuesday(3), wtWebioEA12x12StartWday-Thursday(4), wtWebioEA12x12StartWday-Wednesday(5), wtWebioEA12x12StartWday-Friday(6), wtWebioEA12x12StartWday-Saturday(7)  

wtWebioEA12x12StTzStartHrs 1.3.6.1.4.1.5040.1.2.4.3.1.2.1.10
Hour in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x12StTzStartMin 1.3.6.1.4.1.5040.1.2.4.3.1.2.1.11
Minute in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x12StTzStopMonth 1.3.6.1.4.1.5040.1.2.4.3.1.2.1.12
Month in which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA12x12StopMonth-January(1), wtWebioEA12x12StopMonth-February(2), wtWebioEA12x12StopMonth-March(3), wtWebioEA12x12StopMonth-April(4), wtWebioEA12x12StopMonth-May(5), wtWebioEA12x12StopMonth-June(6), wtWebioEA12x12StopMonth-July(7), wtWebioEA12x12StopMonth-August(8), wtWebioEA12x12StopMonth-September(9), wtWebioEA12x12StopMonth-October(10), wtWebioEA12x12StopMonth-November(11), wtWebioEA12x12StopMonth-December(12)  

wtWebioEA12x12StTzStopMode 1.3.6.1.4.1.5040.1.2.4.3.1.2.1.13
Mode of the week day on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA12x12StopMode-first(1), wtWebioEA12x12StopMode-second(2), wtWebioEA12x12StopMode-third(3), wtWebioEA12x12StopMode-fourth(4), wtWebioEA12x12StopMode-last(5)  

wtWebioEA12x12StTzStopWday 1.3.6.1.4.1.5040.1.2.4.3.1.2.1.14
Day of the week on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA12x12StopWday-Sunday(1), wtWebioEA12x12StopWday-Monday(2), wtWebioEA12x12StopWday-Tuesday(3), wtWebioEA12x12StopWday-Thursday(4), wtWebioEA12x12StopWday-Wednesday(5), wtWebioEA12x12StopWday-Friday(6), wtWebioEA12x12StopWday-Saturday(7)  

wtWebioEA12x12StTzStopHrs 1.3.6.1.4.1.5040.1.2.4.3.1.2.1.15
Hour at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x12StTzStopMin 1.3.6.1.4.1.5040.1.2.4.3.1.2.1.16
Minute at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x12TimeServer1 1.3.6.1.4.1.5040.1.2.4.3.1.2.2.1
IP address or name of the 1st time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12TimeServer2 1.3.6.1.4.1.5040.1.2.4.3.1.2.2.2
IP address or name of the 2nd time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12TsEnable 1.3.6.1.4.1.5040.1.2.4.3.1.2.2.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x12TsSyncTime 1.3.6.1.4.1.5040.1.2.4.3.1.2.2.4
Daily synchronisation time with the time server (hour: 0-23).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x12ClockHrs 1.3.6.1.4.1.5040.1.2.4.3.1.2.3.1
Clock hours taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..23  

wtWebioEA12x12ClockMin 1.3.6.1.4.1.5040.1.2.4.3.1.2.3.2
Clock minutes taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..59  

wtWebioEA12x12ClockDay 1.3.6.1.4.1.5040.1.2.4.3.1.2.3.3
Date: Day of the month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..31  

wtWebioEA12x12ClockMonth 1.3.6.1.4.1.5040.1.2.4.3.1.2.3.4
Date: Month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA12x12ClockMonth-January(1), wtWebioEA12x12ClockMonth-February(2), wtWebioEA12x12ClockMonth-March(3), wtWebioEA12x12ClockMonth-April(4), wtWebioEA12x12ClockMonth-May(5), wtWebioEA12x12ClockMonth-June(6), wtWebioEA12x12ClockMonth-July(7), wtWebioEA12x12ClockMonth-August(8), wtWebioEA12x12ClockMonth-September(9), wtWebioEA12x12ClockMonth-October(10), wtWebioEA12x12ClockMonth-November(11), wtWebioEA12x12ClockMonth-December(12)  

wtWebioEA12x12ClockYear 1.3.6.1.4.1.5040.1.2.4.3.1.2.3.5
Date: Year, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA12x12IpAddress 1.3.6.1.4.1.5040.1.2.4.3.1.3.1.1
IP address of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioEA12x12SubnetMask 1.3.6.1.4.1.5040.1.2.4.3.1.3.1.2
Subnet mask of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioEA12x12Gateway 1.3.6.1.4.1.5040.1.2.4.3.1.3.1.3
Gateway of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioEA12x12DnsServer1 1.3.6.1.4.1.5040.1.2.4.3.1.3.1.4
IP address of the 1st DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12DnsServer2 1.3.6.1.4.1.5040.1.2.4.3.1.3.1.5
IP address of the 2nd DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12AddConfig 1.3.6.1.4.1.5040.1.2.4.3.1.3.1.6
Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP enable Bit 0: BOOTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12Startup 1.3.6.1.4.1.5040.1.2.4.3.1.3.2.1
Binary coded start page, more than one page must not be selected: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2: user.htm Bit 1: home.htm Bit 0: index.htm
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12GetHeaderEnable 1.3.6.1.4.1.5040.1.2.4.3.1.3.2.2
If bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device (Header) or a HTTP header (HTTP): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2-7: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12HttpInputTrigger 1.3.6.1.4.1.5040.1.2.4.3.1.3.2.3
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, Bit 0-3: Digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Digital inputs 0-7
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x12HttpPort 1.3.6.1.4.1.5040.1.2.4.3.1.3.2.4
Definition of the standard HTML port (Default: 80).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65534  

wtWebioEA12x12MailAdName 1.3.6.1.4.1.5040.1.2.4.3.1.3.3.1
Device name for mail administration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12MailReply 1.3.6.1.4.1.5040.1.2.4.3.1.3.3.2
Reply address for the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12MailServer 1.3.6.1.4.1.5040.1.2.4.3.1.3.3.3
Name or IP address of the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12MailEnable 1.3.6.1.4.1.5040.1.2.4.3.1.3.3.4
Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12MailAuthentication 1.3.6.1.4.1.5040.1.2.4.3.1.3.3.5
Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x12MailAuthUser 1.3.6.1.4.1.5040.1.2.4.3.1.3.3.6
Name of the user to be authenticated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12MailAuthPassword 1.3.6.1.4.1.5040.1.2.4.3.1.3.3.7
Authentication password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12MailPop3Server 1.3.6.1.4.1.5040.1.2.4.3.1.3.3.8
Name or Ip-address of the POP3 Servers.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12SnmpEnable 1.3.6.1.4.1.5040.1.2.4.3.1.3.4.1
Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12SnmpCommunityStringRead 1.3.6.1.4.1.5040.1.2.4.3.1.3.4.2
Community string read only
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12SnmpCommunityStringReadWrite 1.3.6.1.4.1.5040.1.2.4.3.1.3.4.3
Community string read / write
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12SnmpSystemTrapManagerIP 1.3.6.1.4.1.5040.1.2.4.3.1.3.4.4
Name or IP address of the TCP server which accepts the system trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12SnmpSystemTrapEnable 1.3.6.1.4.1.5040.1.2.4.3.1.3.4.5
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag messages Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x12UdpAdminPort 1.3.6.1.4.1.5040.1.2.4.3.1.3.5.1
Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x12UdpEnable 1.3.6.1.4.1.5040.1.2.4.3.1.3.5.2
Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12UdpRemotePort 1.3.6.1.4.1.5040.1.2.4.3.1.3.5.3
Udp remote port setting. If this value is set to zero, the source port read from a request will be used as destination port for the answer. A non zero value forced the destination port to this value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x12BinaryModeCount 1.3.6.1.4.1.5040.1.2.4.3.1.3.6.1
Number of independent binary channels.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtWebioEA12x12BinaryIfTable 1.3.6.1.4.1.5040.1.2.4.3.1.3.6.2
Table of indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA12x12BinaryIfEntry

wtWebioEA12x12BinaryIfEntry 1.3.6.1.4.1.5040.1.2.4.3.1.3.6.2.1
Indices of the binary channels.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA12x12BinaryIfEntry  

wtWebioEA12x12BinaryModeNo 1.3.6.1.4.1.5040.1.2.4.3.1.3.6.2.1.1
Number of the binary channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtWebioEA12x12BinaryTable 1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3
Table of properties of the binary mode.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA12x12BinaryEntry

wtWebioEA12x12BinaryEntry 1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1
Binary properties.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA12x12BinaryEntry  

wtWebioEA12x12BinaryOperationMode 1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.1
Selection of the operation mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : UDP Peer Bit 1 : TCP Client Bit 0 : TCP Server
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x12BinaryTcpServerLocalPort 1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.2
Local TCP port for data exchange in this server mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA12x12BinaryTcpServerInputTrigger 1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.3
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, Bit 0-3: Digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Digital inputs 0-7
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x12BinaryTcpServerApplicationMode 1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.4
Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 4-7: unused Bit 3 : OPC Device Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x12BinaryTcpClientLocalPort 1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.5
Local TCP port for data exchange in this client mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA12x12BinaryTcpClientServerPort 1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.6
Port number of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server port to zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA12x12BinaryTcpClientServerIpAddr 1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.7
Ip address of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server IP address to 0.0.0.0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12BinaryTcpClientServerPassword 1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.8
Building a connection may be protected by the administrator password of the server. Enter the server password to establish the connection, if a server administrator password exists.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12BinaryTcpClientInactivity 1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.9
Connection timeout in 100ms. If no data are exchanged within the specified time, the device closes the connection to the server. The value 0 deactivates the timer. Using the Box2Box mode this function is disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x12BinaryTcpClientInputTrigger 1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.10
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, Bit 0-3: Digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Digital inputs 0-7
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x12BinaryTcpClientInterval 1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.11
Configurable interval with a 100ms base, in which the Webio device sends data to the configured application. A interval of zero stopps the periodical sending.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA12x12BinaryTcpClientApplicationMode 1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.12
Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x12BinaryUdpPeerLocalPort 1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.13
Local UDP port for data exchange in this peer to peer mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA12x12BinaryUdpPeerRemotePort 1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.14
Port number of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote port to zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA12x12BinaryUdpPeerRemoteIpAddr 1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.15
Ip address of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote device IP address to 0.0.0.0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12BinaryUdpPeerInputTrigger 1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.16
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, Bit 0-3: Digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Digital inputs 0-7
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x12BinaryUdpPeerInterval 1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.17
Configurable interval with a 100ms base, in which the Webio device sends data to the configured remote device. A interval of zero stopps the periodical sending.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA12x12BinaryUdpPeerApplicationMode 1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.18
Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x12BinaryConnectedPort 1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.19
Port number of the remote device, after connection has been established. In case of no connection or missing port informations a zero will be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA12x12BinaryConnectedIpAddr 1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.20
IP address of the remote device, after connection has been established. In case of no connection or missing port informations 0.0.0.0 will be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

wtWebioEA12x12BinaryTcpServerClientHttpPort 1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.21
HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs status informations will be send to this port. Not used at mode Compatible 50xxx.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA12x12BinaryTcpClientServerHttpPort 1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.22
HTTP port number of the remote device at TCP Client Mode. In the operating mode Box2Box connection status informations will be exchanged through this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA12x12SyslogServerIP 1.3.6.1.4.1.5040.1.2.4.3.1.3.7.1
Name or IP address of the Syslog server, which accepts the Syslog messgaes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12SyslogServerPort 1.3.6.1.4.1.5040.1.2.4.3.1.3.7.2
Portnumber of the Syslog servers, default 514.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x12SyslogSystemMessagesEnable 1.3.6.1.4.1.5040.1.2.4.3.1.3.7.3
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x12SyslogEnable 1.3.6.1.4.1.5040.1.2.4.3.1.3.7.4
Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12FTPServerIP 1.3.6.1.4.1.5040.1.2.4.3.1.3.8.1
Name or IP address of the FTP server, which accepts the FTP messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12FTPServerControlPort 1.3.6.1.4.1.5040.1.2.4.3.1.3.8.2
Portnumber of the control port of the FTP server, default 21.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x12FTPUserName 1.3.6.1.4.1.5040.1.2.4.3.1.3.8.3
FTP Loggin: user name.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12FTPPassword 1.3.6.1.4.1.5040.1.2.4.3.1.3.8.4
FTP Loggin: user password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12FTPAccount 1.3.6.1.4.1.5040.1.2.4.3.1.3.8.5
FTP Loggin: name of account.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12FTPOption 1.3.6.1.4.1.5040.1.2.4.3.1.3.8.6
Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12FTPEnable 1.3.6.1.4.1.5040.1.2.4.3.1.3.8.7
Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12OutputModeTable 1.3.6.1.4.1.5040.1.2.4.3.1.4.1
Table of output mode configurations dependent on the output indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA12x12OutputModeEntry

wtWebioEA12x12OutputModeEntry 1.3.6.1.4.1.5040.1.2.4.3.1.4.1.1
Output mode configurations of the individual outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA12x12OutputModeEntry  

wtWebioEA12x12OutputModeBit 1.3.6.1.4.1.5040.1.2.4.3.1.4.1.1.1
This binary coded output mode defines the individual operation mode for any output. More than one mode must not be selected. The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 6-7: unused Bit 5 : Logic Bit 4 : Binary 2 Bit 3 : Binary 1 Bit 2 : SNMP Bit 1 : UDP ASCII Bit 0 : HTTP
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x12SafetyTimeout 1.3.6.1.4.1.5040.1.2.4.3.1.4.2
After this period of time (multiple of 100ms) without receiving data outputs switch to their Safety States. For each output a independend safety state could be defined.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA12x12LoadControlEnable 1.3.6.1.4.1.5040.1.2.4.3.1.4.3
Here the function of automatic load control can be enabled. All output were tested in pairs (0-1, 2-3, 4-5, 6-7, 8-9, 10-11). If an error occours at one output, both output of an pair will be switched of. For a properly function of the load control each output of a pair have to has a load. If there is no existing load, a pull down resistor can be used. Outputs with no load are automaticly detected and not part of the control function. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Load Control enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12AlarmCount 1.3.6.1.4.1.5040.1.2.4.3.1.5.1
Number of independent alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..12  

wtWebioEA12x12AlarmIfTable 1.3.6.1.4.1.5040.1.2.4.3.1.5.2
List of alarm indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA12x12AlarmIfEntry

wtWebioEA12x12AlarmIfEntry 1.3.6.1.4.1.5040.1.2.4.3.1.5.2.1
Numbers of the alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA12x12AlarmIfEntry  

wtWebioEA12x12AlarmNo 1.3.6.1.4.1.5040.1.2.4.3.1.5.2.1.1
Numbers of the alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..12  

wtWebioEA12x12AlarmTable 1.3.6.1.4.1.5040.1.2.4.3.1.5.3
List of settings depending on the alarm number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA12x12AlarmEntry

wtWebioEA12x12AlarmEntry 1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1
Alarm parameters of the individual alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA12x12AlarmEntry  

wtWebioEA12x12AlarmInputTrigger 1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.1
This variable allows setting of individual input trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the inputs are to be considered (corresponding bit = 1) and which inputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3, Bit 0-3: Mask for digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Mask for digital inputs 0-7 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7, Bit 0-3: Level of digital inputs 8-11 Bit 4-7: unused OCTET 8, Bit 0-7: Level of digital inputs 0-7 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change of the corresponding input bit. Settings in OCTET 5-9 are then unused: OCTET 9 : unused OCTET 10: unsused OCTET 11, Bit 0-7 : ANY bits of digital inputs 8-11 Bit 12-15 : unused OCTET 12, Bit 0-7 : ANY bits of digital inputs 0-7
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(12)  

wtWebioEA12x12AlarmOutputTrigger 1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.2
This variable allows setting of individual output trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be considered (corresponding bit = 1) and which outputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3, Bit 0-3: Mask for digital outputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Mask for digital outputs 0-7 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7, Bit 0-3: Level of digital outputs 8-11 Bit 4-7: unused OCTET 8, Bit 0-7: Level of digital outputs 0-7 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change of the corresponding output bit. Settings in OCTET 5-9 are then unused: OCTET 9 : unused OCTET 11, Bit 0-7 : ANY bits of digital inputs 8-11 Bit 12-15 : unused OCTET 12, Bit 0-7 : ANY bits of digital inputs 0-7
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(12)  

wtWebioEA12x12AlarmSystemTrigger 1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.3
Binary coded trigger conditions: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Warm Start Bit 2 : Cold Start Bit 1 : Timer Bit 0 : Load Control
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x12AlarmMaxCounterValue 1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.4
This variable configures a max. counter value. If an input counter value exceeds this max. value, the corresponding alarm is triggered. Input counters with its mask bit unset in wtWebioEA12x12AlarmInputTrigger are not considered.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12AlarmInterval 1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.5
Send interval for alarm messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12AlarmEnable 1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.6
Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: UDP enable Bit 3: Send inputs to pending TCP connections Bit 4: TCP Client enable Bit 5: Syslog Messages enable Bit 6-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x12AlarmMailAddr 1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.7
E-Mail address for sending the alarm mail to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12AlarmMailSubject 1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.8
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12AlarmMailText 1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.9
Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12AlarmSnmpManagerIP 1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.10
IP address of the SNMP Manager to which the Webio device should send SNMP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12AlarmSnmpTrapText 1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.11
This text appears in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12AlarmUdpIpAddr 1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.12
IP address of the UDP listener to which the Webio device should send UDP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12AlarmUdpPort 1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.13
Port number of the UDP listener to which the Webio device should send UDP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA12x12AlarmUdpText 1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.14
This text appears in the UDP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12AlarmTcpIpAddr 1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.15
IP address of the TCP listener to which the Webio device should send TCP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12AlarmTcpPort 1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.16
Port number of the TCP listener to which the Webio device should send TCP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA12x12AlarmTcpText 1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.17
This text appears in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12AlarmSyslogIpAddr 1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.18
IP address of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12AlarmSyslogPort 1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.19
Port number of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA12x12AlarmSyslogText 1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.20
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12AlarmFtpDataPort 1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.21
Local data port: 1..65535 or AUTO: the next free port will be assigned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12AlarmFtpFileName 1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.22
Name of the file including path informations.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12AlarmFtpText 1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.23
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12AlarmFtpOption 1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.24
Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x12AlarmTimerCron 1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.25
This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12AlarmMailReleaseSubject 1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.26
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12AlarmMailReleaseText 1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.27
Release Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12AlarmSnmpTrapReleaseText 1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.28
This text appears in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12AlarmUdpReleaseText 1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.29
This text appears in the UDP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12AlarmTcpReleaseText 1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.30
This text appears in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12AlarmSyslogReleaseText 1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.31
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12AlarmFtpReleaseText 1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.32
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12LoadControlView 1.3.6.1.4.1.5040.1.2.4.3.1.5.4
Here the result of automatic load control can be read. All output were tested in pairs (0-1, 2-3, 4-5, 6-7, 8-9, 10-11). If an error occours at one output, both output of an pair will be switched of. For a properly function of the load control each output of a pair have to has a load. If there is no existing load, a pull down resistor can be used. Outputs with no load are automaticly detected and not part of the control function. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: unused Octet 3: Bit 4-7: unused Bit 0-3: outputs 8-11 Octet 4: Bit 0-7: outputs 0-7.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x12LCShutDownView 1.3.6.1.4.1.5040.1.2.4.3.1.5.5
Here the result of the automatic load control shut down can be read. All outputs remain switched of, until a zero is written into this variable. But previously all loads should be inspected. High current (short circuit), a broken supply line or a defect load (i.e. lamp) may be a shut down reason. If no load is detected, the load control unit suspend automaticly the control of the corresponding output pair. All controlled output could be identified reading the variable wtWebioEA12x12LoadControlEnable. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: unused Octet 3: Bit 4-7: unused Bit 0-3: outputs 8-11 Octet 4: Bit 0-7: outputs 0-7.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x12InputPortTable 1.3.6.1.4.1.5040.1.2.4.3.2.1
List of settings depending on the input number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA12x12InputPortEntry

wtWebioEA12x12InputPortEntry 1.3.6.1.4.1.5040.1.2.4.3.2.1.1
Input parameter for the individual inputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA12x12InputPortEntry  

wtWebioEA12x12PortInputName 1.3.6.1.4.1.5040.1.2.4.3.2.1.1.1
Name of the input.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12PortInputText 1.3.6.1.4.1.5040.1.2.4.3.2.1.1.2
Description of the input.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12PortInputMode 1.3.6.1.4.1.5040.1.2.4.3.2.1.1.3
Binary coded modes: Selecting short pulse detection enable by setting the corresponding bit to 1 enables interrupt support for counting. Only positive edges are accepted as trigger source. The maximum counting frequenz equals 2000 Hz. This mode is available for inputs 0-3 only. Selecting counter clear on read by setting the corresponding bit to 1 enables the corresponding counter to be cleared automatically every time it is read, except HTTP reading with user rights. The OCTETS are interpreted bit-by-bit, with each set of octets corresponding to an input. Bit 0 corresponds to the LSB. Selection for input 0-3: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 3-7: unused Bit 2 : Counter clear on read Bit 1 : Change detection enable (default) Bit 0 : Short Pulse detection enable Selection for inputs 4-11: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : Counter clear on read Bit 0 : Change detection enable (default)
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x12PortInputFilter 1.3.6.1.4.1.5040.1.2.4.3.2.1.1.4
Pulses with a duration shorter than here specified (duration in 1/1000 sec), are ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x12PortInputBicountPulsePolarity 1.3.6.1.4.1.5040.1.2.4.3.2.1.1.5
This value defines the polarity of the input pulse. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x12PortInputBicountInactivTimeout 1.3.6.1.4.1.5040.1.2.4.3.2.1.1.6
Pulse chains with a duration shorter than here specified (in 1/10 sek), are ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x12OutputPortTable 1.3.6.1.4.1.5040.1.2.4.3.2.2
List of settings depending on the output number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA12x12OutputPortEntry

wtWebioEA12x12OutputPortEntry 1.3.6.1.4.1.5040.1.2.4.3.2.2.1
Output parameters of the individual outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA12x12OutputPortEntry  

wtWebioEA12x12PortOutputName 1.3.6.1.4.1.5040.1.2.4.3.2.2.1.1
Name of the output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12PortOutputText 1.3.6.1.4.1.5040.1.2.4.3.2.2.1.2
Description of the output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12PortOutputGroupMode 1.3.6.1.4.1.5040.1.2.4.3.2.2.1.3
It is possible to connect outputs together to increase the output current. This could be done by connecting 2 or 4 outputs in a group together. All bits of such a group has to be set all together in the same way. This variable configures this group scheme. If one output bit of a group is set, all other output bits of the same group will be set in the same manner. More than one configuration must not be selected. Selection for outputs 0-3: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: Bit 0 : outputs 0,1,2,3 disconnected (default) Bit 1 : outputs 0+1, 2+3 connected Bit 2 : outputs 0+1+2+3 connected Bit 3-7 : unused Selection for outputs 4-7: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: Bit 0 : outputs 4, 5, 6, 7 disconnected (default) Bit 1 : outputs 4+5, 6+7 connected Bit 2 : outputs 4+5+6+7 connected Bit 3-7 : unused Selection for outputs 8-11: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: Bit 0 : outputs 8, 9, 10, 11 disconnected (default) Bit 1 : outputs 8+9, 10+11 connected Bit 2 : outputs 8+9+10+11 connected Bit 3-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12PortOutputSafetyState 1.3.6.1.4.1.5040.1.2.4.3.2.2.1.4
This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 1-7: unused Bit 0 : Mask for digital output OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs to be changed should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 1-7: unused Bit 0 : Level of digital output
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12PortLogicInputMask 1.3.6.1.4.1.5040.1.2.4.3.2.2.1.5
Selecting one of these inputs by setting the corresponding bit to 1 enables the logic function for the output identified by the index within this table. The calculation take place in 4 steps: 1. Selecting inputs (wtWebioEA12x12PortLogicInputMask) 2. Inverting inputs if necessary (wtWebioEA12x12PortLogicInputInverter) 3. Logical combination (wtWebioEA12x12PortLogicFunction) 4. Inverting the result if necessary (wtWebioEA12x12PortLogicOutputInverter) OCTET 1: unused OCTET 2: unused OCTET 3: Bit 0-3 : inputs 8-11 Bit 4-7 : unused OCTET 4: Bit 0-7 : inputs 0-7
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x12PortLogicInputInverter 1.3.6.1.4.1.5040.1.2.4.3.2.2.1.6
Every input bit selected here will be inverted. OCTET 1: unused OCTET 2: unused OCTET 3: Bit 0-3 : inputs 8-11 Bit 4-7 : unused OCTET 4: Bit 0-7 : inputs 0-7
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x12PortLogicFunction 1.3.6.1.4.1.5040.1.2.4.3.2.2.1.7
This determines the logic function. No more than one function may be selected. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : logic function OR (default) Bit 1 : logic function AND Bit 2-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x12PortLogicOutputInverter 1.3.6.1.4.1.5040.1.2.4.3.2.2.1.8
The logical operation result could be inverteted by setting the corresponding bit to 1. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : Output Inverter enable Bit 1-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x12PortPulseDuration 1.3.6.1.4.1.5040.1.2.4.3.2.2.1.9
Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x12PortPulsePolarity 1.3.6.1.4.1.5040.1.2.4.3.2.2.1.10
This value defines the polarity of the output pulse, if wtWebioEA12x12PortPulseDuration is not set to zero. After the pulse is finished, the output switches back to the opposite state. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x12MfName 1.3.6.1.4.1.5040.1.2.4.3.3.1
Manufacturer company name
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12MfAddr 1.3.6.1.4.1.5040.1.2.4.3.3.2
Manufacturer address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12MfHotline 1.3.6.1.4.1.5040.1.2.4.3.3.3
Manufacturer hotline.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12MfInternet 1.3.6.1.4.1.5040.1.2.4.3.3.4
Manufacturer Internet address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12MfDeviceTyp 1.3.6.1.4.1.5040.1.2.4.3.3.5
Manufacturer device name (model number).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12DiagErrorCount 1.3.6.1.4.1.5040.1.2.4.4.1
Number of entries in the error memory.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x12DiagBinaryError 1.3.6.1.4.1.5040.1.2.4.4.2
Error causes coded bit-by-bit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12DiagErrorIndex 1.3.6.1.4.1.5040.1.2.4.4.3
The value of this variable is used as an index to read an error massege from wtWebioEA12x12DiagErrorMessage. Errors are numbered from 1 to wtWebioEA12x12DiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebioEA12x12DiagErrorMessage.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x12DiagErrorMessage 1.3.6.1.4.1.5040.1.2.4.4.4
Using wtWebioEA12x12DiagErrorIndex as an index, the appropriate message is available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x12DiagErrorClear 1.3.6.1.4.1.5040.1.2.4.4.5
Writing 1 into this variable clears all diagnosis messages.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x12Alert1 41
This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x12Alert2 42
This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x12Alert3 43
This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x12Alert4 44
This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x12Alert5 45
This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x12Alert6 46
This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x12Alert7 47
This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x12Alert8 48
This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x12Alert9 49
This SNMP trap is generated when Alarm 9 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x12Alert10 50
This SNMP trap is generated when Alarm 10 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x12Alert11 51
This SNMP trap is generated when Alarm 11 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x12Alert12 52
This SNMP trap is generated when Alarm 12 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x12Alert13 71
This SNMP trap is generated when Alarm 1 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x12Alert14 72
This SNMP trap is generated when Alarm 2 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x12Alert15 73
This SNMP trap is generated when Alarm 3 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x12Alert16 74
This SNMP trap is generated when Alarm 4 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x12Alert17 75
This SNMP trap is generated when Alarm 5 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x12Alert18 76
This SNMP trap is generated when Alarm 6 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x12Alert19 77
This SNMP trap is generated when Alarm 7 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x12Alert20 78
This SNMP trap is generated when Alarm 8 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x12Alert21 79
This SNMP trap is generated when Alarm 9 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x12Alert22 80
This SNMP trap is generated when Alarm 10 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x12Alert23 81
This SNMP trap is generated when Alarm 11 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x12Alert24 82
This SNMP trap is generated when Alarm 12 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x12AlertDiag 110
This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA24oemInputs 1.3.6.1.4.1.5040.1.2.14.1.1
Number of independent inputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..24  

wtWebioEA24oemOutputs 1.3.6.1.4.1.5040.1.2.14.1.2
Number of independent outputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..24  

wtWebioEA24oemInputTable 1.3.6.1.4.1.5040.1.2.14.1.3
List of input indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA24oemInputEntry

wtWebioEA24oemInputEntry 1.3.6.1.4.1.5040.1.2.14.1.3.1
Numbers of the inputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA24oemInputEntry  

wtWebioEA24oemInputNo 1.3.6.1.4.1.5040.1.2.14.1.3.1.1
Index numbers of the inputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA24oemInputCounter 1.3.6.1.4.1.5040.1.2.14.1.3.1.2
Value of the input counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA24oemInputCounterClear 1.3.6.1.4.1.5040.1.2.14.1.3.1.3
Value of the input counter. After reading this counter will be cleared.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA24oemInputState 1.3.6.1.4.1.5040.1.2.14.1.3.1.4
Value of a single input bit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtWebioEA24oemInputState-OFF(0), wtWebioEA24oemInputState-ON(1)  

wtWebioEA24oemInputValue 1.3.6.1.4.1.5040.1.2.14.1.4
This variable is used to read the inputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: Bit 0-7 : inputs 16 - 23 OCTET 3: Bit 0-7 : inputs 8 - 15 OCTET 4: Bit 0-7 : inputs 0 - 7
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA24oemOutputTable 1.3.6.1.4.1.5040.1.2.14.1.5
List of output indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA24oemOutputEntry

wtWebioEA24oemOutputEntry 1.3.6.1.4.1.5040.1.2.14.1.5.1
Numbers of the outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA24oemOutputEntry  

wtWebioEA24oemOutputNo 1.3.6.1.4.1.5040.1.2.14.1.5.1.1
Index numbers of the outputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..24  

wtWebioEA24oemOutputState 1.3.6.1.4.1.5040.1.2.14.1.5.1.2
Value of a single output bit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA24oemOutputState-OFF(0), wtWebioEA24oemOutputState-ON(1)  

wtWebioEA24oemOutputValue 1.3.6.1.4.1.5040.1.2.14.1.6
This variable is used to read and write the outputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: Bit 0-7: Digital outputs 16-23 OCTET 3, Bit 0-7: Digital outputs 8-15 OCTET 4, Bit 0-7: Digital outputs 0-7
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA24oemSetOutput 1.3.6.1.4.1.5040.1.2.14.1.7
This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first two OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1: unused OCTET 2: Bit 0-7: Mask for digital outputs 16-23 OCTET 3, Bit 0-7: Mask for digital outputs 8-15 OCTET 4, Bit 0-7: Mask for digital outputs 0-7 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5: unused OCTET 6: Bit 0-7: Level of digital outputs 16-23 OCTET 7, Bit 0-7: Level of digital outputs 8-15 OCTET 8, Bit 0-7: Level of digital outputs 0-7
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

wtWebioEA24oemSessCntrlPassword 1.3.6.1.4.1.5040.1.2.14.2.1
Entering this password opens a session which is ended by writing a 1 to wtWebioEA24oemSessCntrlLogout. When read this variable provides a string of length zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemSessCntrlConfigMode 1.3.6.1.4.1.5040.1.2.14.2.2
When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtWebioEA24oemSessCntrl-NoSession(0), wtWebioEA24oemSessCntrl-Session(1)  

wtWebioEA24oemSessCntrlLogout 1.3.6.1.4.1.5040.1.2.14.2.3
If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA24oemSessCntrlAdminPassword 1.3.6.1.4.1.5040.1.2.14.2.4
This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemSessCntrlConfigPassword 1.3.6.1.4.1.5040.1.2.14.2.5
This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemDeviceName 1.3.6.1.4.1.5040.1.2.14.3.1.1.1
Name of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemDeviceText 1.3.6.1.4.1.5040.1.2.14.3.1.1.2
Description of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemDeviceLocation 1.3.6.1.4.1.5040.1.2.14.3.1.1.3
Description of the location of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemDeviceContact 1.3.6.1.4.1.5040.1.2.14.3.1.1.4
Contact address of the system operator of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemTzOffsetHrs 1.3.6.1.4.1.5040.1.2.14.3.1.2.1.1
Offset hours for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA24oemTzOffsetMin 1.3.6.1.4.1.5040.1.2.14.3.1.2.1.2
Offset minutes for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA24oemTzEnable 1.3.6.1.4.1.5040.1.2.14.3.1.2.1.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA24oemStTzOffsetHrs 1.3.6.1.4.1.5040.1.2.14.3.1.2.1.4
Offset hours of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA24oemStTzOffsetMin 1.3.6.1.4.1.5040.1.2.14.3.1.2.1.5
Offset minutes of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA24oemStTzEnable 1.3.6.1.4.1.5040.1.2.14.3.1.2.1.6
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA24oemStTzStartMonth 1.3.6.1.4.1.5040.1.2.14.3.1.2.1.7
Month in which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA24oemStartMonth-January(1), wtWebioEA24oemStartMonth-February(2), wtWebioEA24oemStartMonth-March(3), wtWebioEA24oemStartMonth-April(4), wtWebioEA24oemStartMonth-May(5), wtWebioEA24oemStartMonth-June(6), wtWebioEA24oemStartMonth-July(7), wtWebioEA24oemStartMonth-August(8), wtWebioEA24oemStartMonth-September(9), wtWebioEA24oemStartMonth-October(10), wtWebioEA24oemStartMonth-November(11), wtWebioEA24oemStartMonth-December(12)  

wtWebioEA24oemStTzStartMode 1.3.6.1.4.1.5040.1.2.14.3.1.2.1.8
Mode of the day of the week for which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA24oemStartMode-first(1), wtWebioEA24oemStartMode-second(2), wtWebioEA24oemStartMode-third(3), wtWebioEA24oemStartMode-fourth(4), wtWebioEA24oemStartMode-last(5)  

wtWebioEA24oemStTzStartWday 1.3.6.1.4.1.5040.1.2.14.3.1.2.1.9
Day of the week on which the change is made from winter time to summer time
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA24oemStartWday-Sunday(1), wtWebioEA24oemStartWday-Monday(2), wtWebioEA24oemStartWday-Tuesday(3), wtWebioEA24oemStartWday-Thursday(4), wtWebioEA24oemStartWday-Wednesday(5), wtWebioEA24oemStartWday-Friday(6), wtWebioEA24oemStartWday-Saturday(7)  

wtWebioEA24oemStTzStartHrs 1.3.6.1.4.1.5040.1.2.14.3.1.2.1.10
Hour in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA24oemStTzStartMin 1.3.6.1.4.1.5040.1.2.14.3.1.2.1.11
Minute in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA24oemStTzStopMonth 1.3.6.1.4.1.5040.1.2.14.3.1.2.1.12
Month in which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA24oemStopMonth-January(1), wtWebioEA24oemStopMonth-February(2), wtWebioEA24oemStopMonth-March(3), wtWebioEA24oemStopMonth-April(4), wtWebioEA24oemStopMonth-May(5), wtWebioEA24oemStopMonth-June(6), wtWebioEA24oemStopMonth-July(7), wtWebioEA24oemStopMonth-August(8), wtWebioEA24oemStopMonth-September(9), wtWebioEA24oemStopMonth-October(10), wtWebioEA24oemStopMonth-November(11), wtWebioEA24oemStopMonth-December(12)  

wtWebioEA24oemStTzStopMode 1.3.6.1.4.1.5040.1.2.14.3.1.2.1.13
Mode of the week day on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA24oemStopMode-first(1), wtWebioEA24oemStopMode-second(2), wtWebioEA24oemStopMode-third(3), wtWebioEA24oemStopMode-fourth(4), wtWebioEA24oemStopMode-last(5)  

wtWebioEA24oemStTzStopWday 1.3.6.1.4.1.5040.1.2.14.3.1.2.1.14
Day of the week on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA24oemStopWday-Sunday(1), wtWebioEA24oemStopWday-Monday(2), wtWebioEA24oemStopWday-Tuesday(3), wtWebioEA24oemStopWday-Thursday(4), wtWebioEA24oemStopWday-Wednesday(5), wtWebioEA24oemStopWday-Friday(6), wtWebioEA24oemStopWday-Saturday(7)  

wtWebioEA24oemStTzStopHrs 1.3.6.1.4.1.5040.1.2.14.3.1.2.1.15
Hour at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA24oemStTzStopMin 1.3.6.1.4.1.5040.1.2.14.3.1.2.1.16
Minute at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA24oemTimeServer1 1.3.6.1.4.1.5040.1.2.14.3.1.2.2.1
IP address or name of the 1st time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemTimeServer2 1.3.6.1.4.1.5040.1.2.14.3.1.2.2.2
IP address or name of the 2nd time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemTsEnable 1.3.6.1.4.1.5040.1.2.14.3.1.2.2.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA24oemTsSyncTime 1.3.6.1.4.1.5040.1.2.14.3.1.2.2.4
Daily synchronisation time with the time server (hour: 0-23).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA24oemClockHrs 1.3.6.1.4.1.5040.1.2.14.3.1.2.3.1
Clock hours taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..23  

wtWebioEA24oemClockMin 1.3.6.1.4.1.5040.1.2.14.3.1.2.3.2
Clock minutes taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..59  

wtWebioEA24oemClockDay 1.3.6.1.4.1.5040.1.2.14.3.1.2.3.3
Date: Day of the month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..31  

wtWebioEA24oemClockMonth 1.3.6.1.4.1.5040.1.2.14.3.1.2.3.4
Date: Month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA24oemClockMonth-January(1), wtWebioEA24oemClockMonth-February(2), wtWebioEA24oemClockMonth-March(3), wtWebioEA24oemClockMonth-April(4), wtWebioEA24oemClockMonth-May(5), wtWebioEA24oemClockMonth-June(6), wtWebioEA24oemClockMonth-July(7), wtWebioEA24oemClockMonth-August(8), wtWebioEA24oemClockMonth-September(9), wtWebioEA24oemClockMonth-October(10), wtWebioEA24oemClockMonth-November(11), wtWebioEA24oemClockMonth-December(12)  

wtWebioEA24oemClockYear 1.3.6.1.4.1.5040.1.2.14.3.1.2.3.5
Date: Year, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA24oemIpAddress 1.3.6.1.4.1.5040.1.2.14.3.1.3.1.1
IP address of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioEA24oemSubnetMask 1.3.6.1.4.1.5040.1.2.14.3.1.3.1.2
Subnet mask of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioEA24oemGateway 1.3.6.1.4.1.5040.1.2.14.3.1.3.1.3
Gateway of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioEA24oemDnsServer1 1.3.6.1.4.1.5040.1.2.14.3.1.3.1.4
IP address of the 1st DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemDnsServer2 1.3.6.1.4.1.5040.1.2.14.3.1.3.1.5
IP address of the 2nd DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemAddConfig 1.3.6.1.4.1.5040.1.2.14.3.1.3.1.6
Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP enable Bit 0: BOOTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemStartup 1.3.6.1.4.1.5040.1.2.14.3.1.3.2.1
Binary coded start page, more than one page must not be selected: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2: user.htm Bit 1: home.htm Bit 0: index.htm
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemGetHeaderEnable 1.3.6.1.4.1.5040.1.2.14.3.1.3.2.2
If bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device (Header) or a HTTP header (HTTP): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2-7: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemHttpInputTrigger 1.3.6.1.4.1.5040.1.2.14.3.1.3.2.3
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: Bit 0-7 : inputs 16 - 23 OCTET 3: Bit 0-7 : inputs 8 - 15 OCTET 4: Bit 0-7 : inputs 0 - 7
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA24oemHttpPort 1.3.6.1.4.1.5040.1.2.14.3.1.3.2.4
Definition of the standard HTML port (Default: 80).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65534  

wtWebioEA24oemMailAdName 1.3.6.1.4.1.5040.1.2.14.3.1.3.3.1
Device name for mail administration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemMailReply 1.3.6.1.4.1.5040.1.2.14.3.1.3.3.2
Reply address for the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemMailServer 1.3.6.1.4.1.5040.1.2.14.3.1.3.3.3
Name or IP address of the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemMailEnable 1.3.6.1.4.1.5040.1.2.14.3.1.3.3.4
Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemMailAuthentication 1.3.6.1.4.1.5040.1.2.14.3.1.3.3.5
Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA24oemMailAuthUser 1.3.6.1.4.1.5040.1.2.14.3.1.3.3.6
Name of the user to be authenticated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemMailAuthPassword 1.3.6.1.4.1.5040.1.2.14.3.1.3.3.7
Authentication password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemMailPop3Server 1.3.6.1.4.1.5040.1.2.14.3.1.3.3.8
Name or Ip-address of the POP3 Servers.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemSnmpEnable 1.3.6.1.4.1.5040.1.2.14.3.1.3.4.1
Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemSnmpCommunityStringRead 1.3.6.1.4.1.5040.1.2.14.3.1.3.4.2
Community string read only
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemSnmpCommunityStringReadWrite 1.3.6.1.4.1.5040.1.2.14.3.1.3.4.3
Community string read / write
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemSnmpSystemTrapManagerIP 1.3.6.1.4.1.5040.1.2.14.3.1.3.4.4
Name or IP address of the TCP server which accepts the system trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemSnmpSystemTrapEnable 1.3.6.1.4.1.5040.1.2.14.3.1.3.4.5
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA24oemUdpAdminPort 1.3.6.1.4.1.5040.1.2.14.3.1.3.5.1
Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA24oemUdpEnable 1.3.6.1.4.1.5040.1.2.14.3.1.3.5.2
Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemUdpRemotePort 1.3.6.1.4.1.5040.1.2.14.3.1.3.5.3
Udp remote port setting. If this value is set to zero, the source port read from a request will be used as destination port for the answer. A non zero value forced the destination port to this value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA24oemBinaryModeCount 1.3.6.1.4.1.5040.1.2.14.3.1.3.6.1
Number of independent binary channels.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtWebioEA24oemBinaryIfTable 1.3.6.1.4.1.5040.1.2.14.3.1.3.6.2
Table of indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA24oemBinaryIfEntry

wtWebioEA24oemBinaryIfEntry 1.3.6.1.4.1.5040.1.2.14.3.1.3.6.2.1
Indices of the binary channels.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA24oemBinaryIfEntry  

wtWebioEA24oemBinaryModeNo 1.3.6.1.4.1.5040.1.2.14.3.1.3.6.2.1.1
Number of the binary channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtWebioEA24oemBinaryTable 1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3
Table of properties of the binary mode.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA24oemBinaryEntry

wtWebioEA24oemBinaryEntry 1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1
Binary properties.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA24oemBinaryEntry  

wtWebioEA24oemBinaryOperationMode 1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.1
Selection of the operation mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : UDP Peer Bit 1 : TCP Client Bit 0 : TCP Server
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA24oemBinaryTcpServerLocalPort 1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.2
Local TCP port for data exchange in this server mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA24oemBinaryTcpServerInputTrigger 1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.3
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: Bit 0-7 : inputs 16 - 23 OCTET 3: Bit 0-7 : inputs 8 - 15 OCTET 4: Bit 0-7 : inputs 0 - 7
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA24oemBinaryTcpServerApplicationMode 1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.4
Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 4-7: unused Bit 3 : OPC Device Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA24oemBinaryTcpClientLocalPort 1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.5
Local TCP port for data exchange in this client mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA24oemBinaryTcpClientServerPort 1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.6
Port number of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server port to zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA24oemBinaryTcpClientServerIpAddr 1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.7
Ip address of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server IP address to 0.0.0.0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemBinaryTcpClientServerPassword 1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.8
Building a connection may be protected by the administrator password of the server. Enter the server password to establish the connection, if a server administrator password exists.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemBinaryTcpClientInactivity 1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.9
Connection timeout in 100ms. If no data are exchanged within the specified time, the device closes the connection to the server. The value 0 deactivates the timer. Using the Box2Box mode this function is disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA24oemBinaryTcpClientInputTrigger 1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.10
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: Bit 0-7 : inputs 16 - 23 OCTET 3: Bit 0-7 : inputs 8 - 15 OCTET 4: Bit 0-7 : inputs 0 - 7
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA24oemBinaryTcpClientInterval 1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.11
Configurable interval with a 100ms base, in which the Webio device sends data to the configured application. A interval of zero stopps the periodical sending.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA24oemBinaryTcpClientApplicationMode 1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.12
Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA24oemBinaryUdpPeerLocalPort 1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.13
Local UDP port for data exchange in this peer to peer mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA24oemBinaryUdpPeerRemotePort 1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.14
Port number of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote port to zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA24oemBinaryUdpPeerRemoteIpAddr 1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.15
Ip address of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote device IP address to 0.0.0.0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemBinaryUdpPeerInputTrigger 1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.16
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: Bit 0-7 : inputs 16 - 23 OCTET 3: Bit 0-7 : inputs 8 - 15 OCTET 4: Bit 0-7 : inputs 0 - 7
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA24oemBinaryUdpPeerInterval 1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.17
Configurable interval with a 100ms base, in which the Webio device sends data to the configured remote device. A interval of zero stopps the periodical sending.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA24oemBinaryUdpPeerApplicationMode 1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.18
Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA24oemBinaryConnectedPort 1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.19
Port number of the remote device, after connection has been established. In case of no connection or missing port informations a zero will be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA24oemBinaryConnectedIpAddr 1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.20
IP address of the remote device, after connection has been established. In case of no connection or missing port informations 0.0.0.0 will be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

wtWebioEA24oemBinaryTcpServerClientHttpPort 1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.21
HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs status informations will be send to this port. Not used at mode Compatible 50xxx.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA24oemBinaryTcpClientServerHttpPort 1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.22
HTTP port number of the remote device at TCP Client Mode. In the operating mode Box2Box connection status informations will be exchanged through this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA24oemSyslogServerIP 1.3.6.1.4.1.5040.1.2.14.3.1.3.7.1
Name or IP address of the Syslog server, which accepts the Syslog messgaes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemSyslogServerPort 1.3.6.1.4.1.5040.1.2.14.3.1.3.7.2
Portnumber of the Syslog servers, default 514.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA24oemSyslogSystemMessagesEnable 1.3.6.1.4.1.5040.1.2.14.3.1.3.7.3
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA24oemSyslogEnable 1.3.6.1.4.1.5040.1.2.14.3.1.3.7.4
Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemFTPServerIP 1.3.6.1.4.1.5040.1.2.14.3.1.3.8.1
Name or IP address of the FTP server, which accepts the FTP messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemFTPServerControlPort 1.3.6.1.4.1.5040.1.2.14.3.1.3.8.2
Portnumber of the control port of the FTP server, default 21.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA24oemFTPUserName 1.3.6.1.4.1.5040.1.2.14.3.1.3.8.3
FTP Loggin: user name.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemFTPPassword 1.3.6.1.4.1.5040.1.2.14.3.1.3.8.4
FTP Loggin: user password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemFTPAccount 1.3.6.1.4.1.5040.1.2.14.3.1.3.8.5
FTP Loggin: name of account.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemFTPOption 1.3.6.1.4.1.5040.1.2.14.3.1.3.8.6
Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemFTPEnable 1.3.6.1.4.1.5040.1.2.14.3.1.3.8.7
Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemOutputModeTable 1.3.6.1.4.1.5040.1.2.14.3.1.4.1
Table of output mode configurations dependent on the output indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA24oemOutputModeEntry

wtWebioEA24oemOutputModeEntry 1.3.6.1.4.1.5040.1.2.14.3.1.4.1.1
Output mode configurations of the individual outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA24oemOutputModeEntry  

wtWebioEA24oemOutputModeBit 1.3.6.1.4.1.5040.1.2.14.3.1.4.1.1.1
This binary coded output mode defines the individual operation mode for any output. More than one mode must not be selected. The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 6-7: unused Bit 5 : Logic Bit 4 : Binary 2 Bit 3 : Binary 1 Bit 2 : SNMP Bit 1 : UDP ASCII Bit 0 : HTTP
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA24oemSafetyTimeout 1.3.6.1.4.1.5040.1.2.14.3.1.4.2
After this period of time (multiple of 100ms) without receiving data outputs switch to their Safety States. For each output a independend safety state could be defined.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA24oemLoadControlEnable 1.3.6.1.4.1.5040.1.2.14.3.1.4.3
Here the function of automatic load control can be enabled. All output were tested in pairs (0-1, 2-3, 4-5, 6-7, 8-9, 10-11). If an error occours at one output, both output of an pair will be switched of. For a properly function of the load control each output of a pair have to has a load. If there is no existing load, a pull down resistor can be used. Outputs with no load are automaticly detected and not part of the control function. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Load Control enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemAlarmCount 1.3.6.1.4.1.5040.1.2.14.3.1.5.1
Number of independent alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..12  

wtWebioEA24oemAlarmIfTable 1.3.6.1.4.1.5040.1.2.14.3.1.5.2
List of alarm indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA24oemAlarmIfEntry

wtWebioEA24oemAlarmIfEntry 1.3.6.1.4.1.5040.1.2.14.3.1.5.2.1
Numbers of the alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA24oemAlarmIfEntry  

wtWebioEA24oemAlarmNo 1.3.6.1.4.1.5040.1.2.14.3.1.5.2.1.1
Numbers of the alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..12  

wtWebioEA24oemAlarmTable 1.3.6.1.4.1.5040.1.2.14.3.1.5.3
List of settings depending on the alarm number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA24oemAlarmEntry

wtWebioEA24oemAlarmEntry 1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1
Alarm parameters of the individual alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA24oemAlarmEntry  

wtWebioEA24oemAlarmInputTrigger 1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.1
This variable allows setting of individual input trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the inputs are to be considered (corresponding bit = 1) and which inputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2: Bit 0-7: Mask for digital inputs 16-23 OCTET 3, Bit 0-7: Mask for digital inputs 8-15 OCTET 4, Bit 0-7: Mask for digital inputs 0-7 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6: Bit 0-7: Level of digital inputs 16-23 OCTET 7, Bit 0-7: Level of digital inputs 8-15 OCTET 8, Bit 0-7: Level of digital inputs 0-7 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change of the corresponding input bit. Settings in OCTET 5-9 are then unused: OCTET 9: unused OCTET 10, Bit 0-7: ANY bits of digital inputs 16-23 OCTET 11, Bit 0-7: ANY bits of digital inputs 8-15 OCTET 12, Bit 0-7: ANY bits of digital inputs 0-7
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(12)  

wtWebioEA24oemAlarmOutputTrigger 1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.2
This variable allows setting of individual output trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be considered (corresponding bit = 1) and which outputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2: Bit 0-7: Mask for digital outputs 16-23 OCTET 3, Bit 0-7: Mask for digital outputs 8-15 OCTET 4, Bit 0-7: Mask for digital outputs 0-7 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6: Bit 0-7: Level of digital outputs 16-23 OCTET 7, Bit 0-7: Level of digital outputs 8-15 OCTET 8, Bit 0-7: Level of digital outputs 0-7 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change of the corresponding output bit. Settings in OCTET 5-9 are then unused: OCTET 9: unused OCTET 10, Bit 0-7: ANY bits of digital outputs 16-23 OCTET 11, Bit 0-7: ANY bits of digital outputs 8-15 OCTET 12, Bit 0-7: ANY bits of digital outputs 0-7
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(12)  

wtWebioEA24oemAlarmSystemTrigger 1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.3
Binary coded trigger conditions: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Warm Start Bit 2 : Cold Start Bit 1 : Timer Bit 0 : Load Control
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA24oemAlarmMaxCounterValue 1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.4
This variable configures a max. counter value. If an input counter value exceeds this max. value, the corresponding alarm is triggered. Input counters with its mask bit unset in wtWebioEA24oemAlarmInputTrigger are not considered.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemAlarmInterval 1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.5
Send interval for alarm messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemAlarmEnable 1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.6
Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: UDP enable Bit 3: Send inputs to pending TCP connections Bit 4-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA24oemAlarmMailAddr 1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.7
E-Mail address for sending the alarm mail to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemAlarmMailSubject 1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.8
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemAlarmMailText 1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.9
Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemAlarmSnmpManagerIP 1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.10
IP address of the SNMP Manager to which the Webio device should send SNMP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemAlarmSnmpTrapText 1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.11
This text appears in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemAlarmUdpIpAddr 1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.12
IP address of the UDP listener to which the Webio device should send UDP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemAlarmUdpPort 1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.13
Port number of the UDP listener to which the Webio device should send UDP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA24oemAlarmUdpText 1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.14
This text appears in the UDP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemAlarmTcpIpAddr 1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.15
IP address of the TCP listener to which the Webio device should send TCP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemAlarmTcpPort 1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.16
Port number of the TCP listener to which the Webio device should send TCP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA24oemAlarmTcpText 1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.17
This text appears in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemAlarmSyslogIpAddr 1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.18
IP address of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemAlarmSyslogPort 1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.19
Port number of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA24oemAlarmSyslogText 1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.20
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemAlarmFtpDataPort 1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.21
Local data port: 1..65535 or AUTO: the next free port will be assigned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemAlarmFtpFileName 1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.22
Name of the file including path informations.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemAlarmFtpText 1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.23
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemAlarmFtpOption 1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.24
Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA24oemAlarmTimerCron 1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.25
This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemLoadControlView 1.3.6.1.4.1.5040.1.2.14.3.1.5.4
Here the result of automatic load control can be read. All output were tested in pairs (0-1, 2-3, 4-5, 6-7, 8-9, 10-11). If an error occours at one output, both output of an pair will be switched of. For a properly function of the load control each output of a pair have to has a load. If there is no existing load, a pull down resistor can be used. Outputs with no load are automaticly detected and not part of the control function. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. Octet 1: unused OCTET 2: Bit 0-7 : outputs 16 - 23 OCTET 3: Bit 0-7 : outputs 8 - 15 OCTET 4: Bit 0-7 : outputs 0 - 7
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA24oemLCShutDownView 1.3.6.1.4.1.5040.1.2.14.3.1.5.5
Here the result of the automatic load control shut down can be read. All outputs remain switched of, until a zero is written into this variable. But previously all loads should be inspected. High current (short circuit), a broken supply line or a defect load (i.e. lamp) may be a shut down reason. If no load is detected, the load control unit suspend automaticly the control of the corresponding output pair. All controlled output could be identified reading the variable wtWebioEA24oemLoadControlEnable. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. Octet 1: unused OCTET 2: Bit 0-7 : outputs 16 - 23 OCTET 3: Bit 0-7 : outputs 8 - 15 OCTET 4: Bit 0-7 : outputs 0 - 7
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA24oemInputPortTable 1.3.6.1.4.1.5040.1.2.14.3.2.1
List of settings depending on the input number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA24oemInputPortEntry

wtWebioEA24oemInputPortEntry 1.3.6.1.4.1.5040.1.2.14.3.2.1.1
Input parameter for the individual inputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA24oemInputPortEntry  

wtWebioEA24oemPortInputName 1.3.6.1.4.1.5040.1.2.14.3.2.1.1.1
Name of the input.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemPortInputText 1.3.6.1.4.1.5040.1.2.14.3.2.1.1.2
Description of the input.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemPortInputMode 1.3.6.1.4.1.5040.1.2.14.3.2.1.1.3
Binary coded modes: Selecting short pulse detection enable by setting the corresponding bit to 1 enables interrupt support for counting. Only positive edges are accepted as trigger source. The maximum counting frequenz equals 2000 Hz. This mode is available for inputs 0-3 only. Selecting counter clear on read by setting the corresponding bit to 1 enables the corresponding counter to be cleared automatically every time it is read, except HTTP reading with user rights. The OCTETS are interpreted bit-by-bit, with each set of octets corresponding to an input. Bit 0 corresponds to the LSB. Selection for input 0-3: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 2 : Counter clear on read Bit 1 : Change detection enable (default) Bit 0 : Short Pulse detection enable Selection for inputs 4-11: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : Counter clear on read Bit 0 : Change detection enable (default)
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA24oemPortInputFilter 1.3.6.1.4.1.5040.1.2.14.3.2.1.1.4
Pulses with a duration shorter than here specified (duration in 1/1000 sec), are ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA24oemOutputPortTable 1.3.6.1.4.1.5040.1.2.14.3.2.2
List of settings depending on the output number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA24oemOutputPortEntry

wtWebioEA24oemOutputPortEntry 1.3.6.1.4.1.5040.1.2.14.3.2.2.1
Output parameters of the individual outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA24oemOutputPortEntry  

wtWebioEA24oemPortOutputName 1.3.6.1.4.1.5040.1.2.14.3.2.2.1.1
Name of the output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemPortOutputText 1.3.6.1.4.1.5040.1.2.14.3.2.2.1.2
Description of the output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemPortOutputGroupMode 1.3.6.1.4.1.5040.1.2.14.3.2.2.1.3
It is possible to connect outputs together to increase the output current. This could be done by connecting 2 or 4 outputs in a group together. All bits of such a group has to be set all together in the same way. This variable configures this group scheme. If one output bit of a group is set, all other output bits of the same group will be set in the same manner. More than one configuration must not be selected. Selection for outputs 0-3: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: Bit 0 : outputs 0,1,2,3 disconnected (default) Bit 1 : outputs 0+1, 2+3 connected Bit 2 : outputs 0+1+2+3 connected Bit 3-7 : unused Selection for outputs 4-7: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: Bit 0 : outputs 4, 5, 6, 7 disconnected (default) Bit 1 : outputs 4+5, 6+7 connected Bit 2 : outputs 4+5+6+7 connected Bit 3-7 : unused Selection for outputs 8-11: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: Bit 0 : outputs 8, 9, 10, 11 disconnected (default) Bit 1 : outputs 8+9, 10+11 connected Bit 2 : outputs 8+9+10+11 connected Bit 3-7 : unused Selection for outputs 12-15: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : outputs 12,13,14,15 disconnected (default) Bit 1 : outputs 12+13,14+15 connected Bit 2 : outputs 12+13+14+15 connected Bit 3-7 : unused Selection for outputs 16-19: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : outputs 16,17,18,19 disconnected (default) Bit 1 : outputs 16+17,18+19 connected Bit 2 : outputs 16+17+18+19 connected Bit 3-7 : unused Selection for outputs 20-23: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : outputs 20,21,22,23 disconnected (default) Bit 1 : outputs 20+21,22+23 connected Bit 2 : outputs 20+21+22+23 connected Bit 3-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemPortOutputSafetyState 1.3.6.1.4.1.5040.1.2.14.3.2.2.1.4
This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 1-7: unused Bit 0 : Mask for digital output OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs to be changed should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 1-7: unused Bit 0 : Level of digital output
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemPortLogicInputMask 1.3.6.1.4.1.5040.1.2.14.3.2.2.1.5
Selecting one of these inputs by setting the corresponding bit to 1 enables the logic function for the output identified by the index within this table. The calculation take place in 4 steps: 1. Selecting inputs (wtWebioEA24oemPortLogicInputMask) 2. Inverting inputs if necessary (wtWebioEA24oemPortLogicInputInverter) 3. Logical combination (wtWebioEA24oemPortLogicFunction) 4. Inverting the result if necessary (wtWebioEA24oemPortLogicOutputInverter) OCTET 1: unused OCTET 2: Bit 0-7 : inputs 16 - 23 OCTET 3: Bit 0-7 : inputs 8 - 15 OCTET 4: Bit 0-7 : inputs 0 - 7
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA24oemPortLogicInputInverter 1.3.6.1.4.1.5040.1.2.14.3.2.2.1.6
Every input bit selected here will be inverted. OCTET 1: unused OCTET 2: Bit 0-7 : inputs 16 - 23 OCTET 3: Bit 0-7 : inputs 8 - 15 OCTET 4: Bit 0-7 : inputs 0 - 7
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA24oemPortLogicFunction 1.3.6.1.4.1.5040.1.2.14.3.2.2.1.7
This determines the logic function. No more than one function may be selected. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : logic function OR (default) Bit 1 : logic function AND Bit 2-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA24oemPortLogicOutputInverter 1.3.6.1.4.1.5040.1.2.14.3.2.2.1.8
The logical operation result could be inverteted by setting the corresponding bit to 1. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : Output Inverter enable Bit 1-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA24oemPortPulseDuration 1.3.6.1.4.1.5040.1.2.14.3.2.2.1.9
Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA24oemPortPulsePolarity 1.3.6.1.4.1.5040.1.2.14.3.2.2.1.10
This value defines the polarity of the output pulse, if wtWebioEA24oemPortPulseDuration is not set to zero. After the pulse is finished, the output switches back to the opposite state. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : ungenutzt
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA24oemMfName 1.3.6.1.4.1.5040.1.2.14.3.3.1
Manufacturer company name
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemMfAddr 1.3.6.1.4.1.5040.1.2.14.3.3.2
Manufacturer address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemMfHotline 1.3.6.1.4.1.5040.1.2.14.3.3.3
Manufacturer hotline.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemMfInternet 1.3.6.1.4.1.5040.1.2.14.3.3.4
Manufacturer Internet address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemMfDeviceTyp 1.3.6.1.4.1.5040.1.2.14.3.3.5
Manufacturer device name (model number).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemDiagErrorCount 1.3.6.1.4.1.5040.1.2.14.4.1
Number of entries in the error memory.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA24oemDiagBinaryError 1.3.6.1.4.1.5040.1.2.14.4.2
Error causes coded bit-by-bit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemDiagErrorIndex 1.3.6.1.4.1.5040.1.2.14.4.3
The value of this variable is used as an index to read an error massege from wtWebioEA24oemDiagErrorMessage. Errors are numbered from 1 to wtWebioEA24oemDiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebioEA24oemDiagErrorMessage.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA24oemDiagErrorMessage 1.3.6.1.4.1.5040.1.2.14.4.4
Using wtWebioEA24oemDiagErrorIndex as an index, the appropriate message is available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA24oemDiagErrorClear 1.3.6.1.4.1.5040.1.2.14.4.5
Writing 1 into this variable clears all diagnosis messages.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA24oemAlert1 53
This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA24oemAlert2 54
This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA24oemAlert3 55
This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA24oemAlert4 56
This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA24oemAlert5 57
This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA24oemAlert6 58
This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA24oemAlert7 59
This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA24oemAlert8 60
This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA24oemAlert9 61
This SNMP trap is generated when Alarm 9 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA24oemAlert10 62
This SNMP trap is generated when Alarm 10 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA24oemAlert11 63
This SNMP trap is generated when Alarm 11 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA24oemAlert12 64
This SNMP trap is generated when Alarm 12 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA24oemAlert13 65
This SNMP trap is generated when Alarm 13 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA24oemAlert14 66
This SNMP trap is generated when Alarm 14 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA24oemAlert15 67
This SNMP trap is generated when Alarm 15 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA24oemAlert16 68
This SNMP trap is generated when Alarm 16 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA24oemAlert17 71
This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA24oemAlert18 72
This SNMP trap is generated when Alarm 2 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA24oemAlert19 73
This SNMP trap is generated when Alarm 3 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA24oemAlert20 74
This SNMP trap is generated when Alarm 4 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA24oemAlert21 75
This SNMP trap is generated when Alarm 5 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA24oemAlert22 76
This SNMP trap is generated when Alarm 6 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA24oemAlert23 77
This SNMP trap is generated when Alarm 7 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA24oemAlert24 78
This SNMP trap is generated when Alarm 8 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA24oemAlert25 79
This SNMP trap is generated when Alarm 9 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA24oemAlert26 80
This SNMP trap is generated when Alarm 10 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA24oemAlert27 81
This SNMP trap is generated when Alarm 11 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA24oemAlert28 82
This SNMP trap is generated when Alarm 12 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA24oemAlert29 83
This SNMP trap is generated when Alarm 13 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA24oemAlert30 84
This SNMP trap is generated when Alarm 14 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA24oemAlert31 85
This SNMP trap is generated when Alarm 15 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA24oemAlert32 86
This SNMP trap is generated when Alarm 16 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA24oemAlertDiag 110
Dieser SNMP-Trap wird generiert, wenn eine Diagnose/Error-Message ausgelst wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist.
TRAP-TYPE    

wtWebioEA12x6RelInputs 1.3.6.1.4.1.5040.1.2.19.1.1
Number of idependent inputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..12  

wtWebioEA12x6RelOutputs 1.3.6.1.4.1.5040.1.2.19.1.2
Number of independent outputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..6  

wtWebioEA12x6RelInputTable 1.3.6.1.4.1.5040.1.2.19.1.3
List of input indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA12x6RelInputEntry

wtWebioEA12x6RelInputEntry 1.3.6.1.4.1.5040.1.2.19.1.3.1
Number of the inputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA12x6RelInputEntry  

wtWebioEA12x6RelInputNo 1.3.6.1.4.1.5040.1.2.19.1.3.1.1
Index numbers of the inputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebioEA12x6RelInputCounter 1.3.6.1.4.1.5040.1.2.19.1.3.1.2
Value of the input counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebioEA12x6RelInputCounterClear 1.3.6.1.4.1.5040.1.2.19.1.3.1.3
Clears the input counter after returning its value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelInputValue 1.3.6.1.4.1.5040.1.2.19.1.4
This variable is used to read the inputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, Bit 0-3: Digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Digital inputs 0-7
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelOutputTable 1.3.6.1.4.1.5040.1.2.19.1.5
List of output indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA12x6RelOutputEntry

wtWebioEA12x6RelOutputEntry 1.3.6.1.4.1.5040.1.2.19.1.5.1
Number of the outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA12x6RelOutputEntry  

wtWebioEA12x6RelOutputNo 1.3.6.1.4.1.5040.1.2.19.1.5.1.1
Output number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebioEA12x6RelOutputState 1.3.6.1.4.1.5040.1.2.19.1.5.1.2
Setting and reading of the states of the outputs.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA12x6RelOutputState-OFF(0), wtWebioEA12x6OutputState-ON(1)  

wtWebioEA12x6RelOutputValue 1.3.6.1.4.1.5040.1.2.19.1.6
This variable is used to read and write the outputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0-5: Digital outputs 0-5
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelSetOutput 1.3.6.1.4.1.5040.1.2.19.1.7
This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first two OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4 : Bit 0-5: Mask for digital outputs 0-5 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8 : Bit 0-5: Level of digital outputs 0-5
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

wtWebioEA12x6RelSessCntrlPassword 1.3.6.1.4.1.5040.1.2.19.2.1
Entering this password opens a session which is ended by writing a 1 to wtWebioEA12x6RelSessCntrlLogout. When read this variable provides a string of length zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelSessCntrlConfigMode 1.3.6.1.4.1.5040.1.2.19.2.2
When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtWebioEA12x6RelSessCntrl-NoSession(0), wtWebioEA12x6RelSessCntrl-Session(1)  

wtWebioEA12x6RelSessCntrlLogout 1.3.6.1.4.1.5040.1.2.19.2.3
If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelSessCntrlAdminPassword 1.3.6.1.4.1.5040.1.2.19.2.4
This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelSessCntrlConfigPassword 1.3.6.1.4.1.5040.1.2.19.2.5
This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelDeviceName 1.3.6.1.4.1.5040.1.2.19.3.1.1.1
Name of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelDeviceText 1.3.6.1.4.1.5040.1.2.19.3.1.1.2
Description of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelDeviceLocation 1.3.6.1.4.1.5040.1.2.19.3.1.1.3
Description of the location of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelDeviceContact 1.3.6.1.4.1.5040.1.2.19.3.1.1.4
Contact address of the system operator of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelTzOffsetHrs 1.3.6.1.4.1.5040.1.2.19.3.1.2.1.1
Offset hours for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelTzOffsetMin 1.3.6.1.4.1.5040.1.2.19.3.1.2.1.2
Offset minutes for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelTzEnable 1.3.6.1.4.1.5040.1.2.19.3.1.2.1.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelStTzOffsetHrs 1.3.6.1.4.1.5040.1.2.19.3.1.2.1.4
Offset hours of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelStTzOffsetMin 1.3.6.1.4.1.5040.1.2.19.3.1.2.1.5
Offset minutes of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelStTzEnable 1.3.6.1.4.1.5040.1.2.19.3.1.2.1.6
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelStTzStartMonth 1.3.6.1.4.1.5040.1.2.19.3.1.2.1.7
Month in which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA12x6RelStartMonth-January(1), wtWebioEA12x6RelStartMonth-February(2), wtWebioEA12x6RelStartMonth-March(3), wtWebioEA12x6RelStartMonth-April(4), wtWebioEA12x6RelStartMonth-May(5), wtWebioEA12x6RelStartMonth-June(6), wtWebioEA12x6RelStartMonth-July(7), wtWebioEA12x6RelStartMonth-August(8), wtWebioEA12x6RelStartMonth-September(9), wtWebioEA12x6RelStartMonth-October(10), wtWebioEA12x6RelStartMonth-November(11), wtWebioEA12x6RelStartMonth-December(12)  

wtWebioEA12x6RelStTzStartMode 1.3.6.1.4.1.5040.1.2.19.3.1.2.1.8
Mode of the day of the week for which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA12x6RelStartMode-first(1), wtWebioEA12x6RelStartMode-second(2), wtWebioEA12x6RelStartMode-third(3), wtWebioEA12x6RelStartMode-fourth(4), wtWebioEA12x6RelStartMode-last(5)  

wtWebioEA12x6RelStTzStartWday 1.3.6.1.4.1.5040.1.2.19.3.1.2.1.9
Day of the week on which the change is made from winter time to summer time
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA12x6RelStartWday-Sunday(1), wtWebioEA12x6RelStartWday-Monday(2), wtWebioEA12x6RelStartWday-Tuesday(3), wtWebioEA12x6RelStartWday-Thursday(4), wtWebioEA12x6RelStartWday-Wednesday(5), wtWebioEA12x6RelStartWday-Friday(6), wtWebioEA12x6RelStartWday-Saturday(7)  

wtWebioEA12x6RelStTzStartHrs 1.3.6.1.4.1.5040.1.2.19.3.1.2.1.10
Hour in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelStTzStartMin 1.3.6.1.4.1.5040.1.2.19.3.1.2.1.11
Minute in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelStTzStopMonth 1.3.6.1.4.1.5040.1.2.19.3.1.2.1.12
Month in which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA12x6RelStopMonth-January(1), wtWebioEA12x6RelStopMonth-February(2), wtWebioEA12x6RelStopMonth-March(3), wtWebioEA12x6RelStopMonth-April(4), wtWebioEA12x6RelStopMonth-May(5), wtWebioEA12x6RelStopMonth-June(6), wtWebioEA12x6RelStopMonth-July(7), wtWebioEA12x6RelStopMonth-August(8), wtWebioEA12x6RelStopMonth-September(9), wtWebioEA12x6RelStopMonth-October(10), wtWebioEA12x6RelStopMonth-November(11), wtWebioEA12x6RelStopMonth-December(12)  

wtWebioEA12x6RelStTzStopMode 1.3.6.1.4.1.5040.1.2.19.3.1.2.1.13
Mode of the week day on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA12x6RelStopMode-first(1), wtWebioEA12x6RelStopMode-second(2), wtWebioEA12x6RelStopMode-third(3), wtWebioEA12x6RelStopMode-fourth(4), wtWebioEA12x6RelStopMode-last(5)  

wtWebioEA12x6RelStTzStopWday 1.3.6.1.4.1.5040.1.2.19.3.1.2.1.14
Day of the week on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA12x6RelStopWday-Sunday(1), wtWebioEA12x6RelStopWday-Monday(2), wtWebioEA12x6RelStopWday-Tuesday(3), wtWebioEA12x6RelStopWday-Thursday(4), wtWebioEA12x6RelStopWday-Wednesday(5), wtWebioEA12x6RelStopWday-Friday(6), wtWebioEA12x6RelStopWday-Saturday(7)  

wtWebioEA12x6RelStTzStopHrs 1.3.6.1.4.1.5040.1.2.19.3.1.2.1.15
Hour at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelStTzStopMin 1.3.6.1.4.1.5040.1.2.19.3.1.2.1.16
Minute at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelTimeServer1 1.3.6.1.4.1.5040.1.2.19.3.1.2.2.1
IP address or name of the 1st time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelTimeServer2 1.3.6.1.4.1.5040.1.2.19.3.1.2.2.2
IP address or name of the 2nd time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelTsEnable 1.3.6.1.4.1.5040.1.2.19.3.1.2.2.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelTsSyncTime 1.3.6.1.4.1.5040.1.2.19.3.1.2.2.4
Daily synchronisation time with the time server (hour: 0-23).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelClockHrs 1.3.6.1.4.1.5040.1.2.19.3.1.2.3.1
Clock hours taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..23  

wtWebioEA12x6RelClockMin 1.3.6.1.4.1.5040.1.2.19.3.1.2.3.2
Clock minutes taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..59  

wtWebioEA12x6RelClockDay 1.3.6.1.4.1.5040.1.2.19.3.1.2.3.3
Date: Day of the month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..31  

wtWebioEA12x6RelClockMonth 1.3.6.1.4.1.5040.1.2.19.3.1.2.3.4
Date: Month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA12x6RelClockMonth-January(1), wtWebioEA12x6RelClockMonth-February(2), wtWebioEA12x6RelClockMonth-March(3), wtWebioEA12x6RelClockMonth-April(4), wtWebioEA12x6RelClockMonth-May(5), wtWebioEA12x6RelClockMonth-June(6), wtWebioEA12x6RelClockMonth-July(7), wtWebioEA12x6RelClockMonth-August(8), wtWebioEA12x6RelClockMonth-September(9), wtWebioEA12x6RelClockMonth-October(10), wtWebioEA12x6RelClockMonth-November(11), wtWebioEA12x6RelClockMonth-December(12)  

wtWebioEA12x6RelClockYear 1.3.6.1.4.1.5040.1.2.19.3.1.2.3.5
Date: Year, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA12x6RelIpAddress 1.3.6.1.4.1.5040.1.2.19.3.1.3.1.1
IP address of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioEA12x6RelSubnetMask 1.3.6.1.4.1.5040.1.2.19.3.1.3.1.2
Subnet mask of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioEA12x6RelGateway 1.3.6.1.4.1.5040.1.2.19.3.1.3.1.3
Gateway of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioEA12x6RelDnsServer1 1.3.6.1.4.1.5040.1.2.19.3.1.3.1.4
IP address of the 1st DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelDnsServer2 1.3.6.1.4.1.5040.1.2.19.3.1.3.1.5
IP address of the 2nd DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelAddConfig 1.3.6.1.4.1.5040.1.2.19.3.1.3.1.6
Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP enable Bit 0: BOOTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelStartup 1.3.6.1.4.1.5040.1.2.19.3.1.3.2.1
Binary coded start page, more than one page must not be selected: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2: user.htm Bit 1: home.htm Bit 0: index.htm
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelGetHeaderEnable 1.3.6.1.4.1.5040.1.2.19.3.1.3.2.2
If bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device (Header) or a HTTP header (HTTP): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2-7: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelHttpInputTrigger 1.3.6.1.4.1.5040.1.2.19.3.1.3.2.3
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, Bit 0-3: Digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Digital inputs 0-7
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelHttpPort 1.3.6.1.4.1.5040.1.2.19.3.1.3.2.4
Definition of the standard HTML port (Default: 80).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65534  

wtWebioEA12x6RelMailAdName 1.3.6.1.4.1.5040.1.2.19.3.1.3.3.1
Device name for mail administration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelMailReply 1.3.6.1.4.1.5040.1.2.19.3.1.3.3.2
Reply address for the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelMailServer 1.3.6.1.4.1.5040.1.2.19.3.1.3.3.3
Name or IP address of the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelMailEnable 1.3.6.1.4.1.5040.1.2.19.3.1.3.3.4
Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelMailAuthentication 1.3.6.1.4.1.5040.1.2.19.3.1.3.3.5
Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelMailAuthUser 1.3.6.1.4.1.5040.1.2.19.3.1.3.3.6
Name of the user to be authenticated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelMailAuthPassword 1.3.6.1.4.1.5040.1.2.19.3.1.3.3.7
Authentication password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelMailPop3Server 1.3.6.1.4.1.5040.1.2.19.3.1.3.3.8
Name or Ip-address of the POP3 Servers.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelSnmpEnable 1.3.6.1.4.1.5040.1.2.19.3.1.3.4.1
Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelSnmpCommunityStringRead 1.3.6.1.4.1.5040.1.2.19.3.1.3.4.2
Community string read only
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelSnmpCommunityStringReadWrite 1.3.6.1.4.1.5040.1.2.19.3.1.3.4.3
Community string read / write
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelSnmpSystemTrapManagerIP 1.3.6.1.4.1.5040.1.2.19.3.1.3.4.4
Name or IP address of the TCP server which accepts the system trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelSnmpSystemTrapEnable 1.3.6.1.4.1.5040.1.2.19.3.1.3.4.5
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag messages Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelUdpAdminPort 1.3.6.1.4.1.5040.1.2.19.3.1.3.5.1
Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelUdpEnable 1.3.6.1.4.1.5040.1.2.19.3.1.3.5.2
Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelUdpRemotePort 1.3.6.1.4.1.5040.1.2.19.3.1.3.5.3
Udp remote port setting. If this value is set to zero, the source port read from a request will be used as destination port for the answer. A non zero value forced the destination port to this value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelBinaryModeCount 1.3.6.1.4.1.5040.1.2.19.3.1.3.6.1
Number of independent binary channels.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtWebioEA12x6RelBinaryIfTable 1.3.6.1.4.1.5040.1.2.19.3.1.3.6.2
Table of indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA12x6RelBinaryIfEntry

wtWebioEA12x6RelBinaryIfEntry 1.3.6.1.4.1.5040.1.2.19.3.1.3.6.2.1
Indices of the binary channels.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA12x6RelBinaryIfEntry  

wtWebioEA12x6RelBinaryModeNo 1.3.6.1.4.1.5040.1.2.19.3.1.3.6.2.1.1
Number of the binary channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtWebioEA12x6RelBinaryTable 1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3
Table of properties of the binary mode.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA12x6RelBinaryEntry

wtWebioEA12x6RelBinaryEntry 1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1
Binary properties.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA12x6RelBinaryEntry  

wtWebioEA12x6RelBinaryOperationMode 1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.1
Selection of the operation mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : UDP Peer Bit 1 : TCP Client Bit 0 : TCP Server
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelBinaryTcpServerLocalPort 1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.2
Local TCP port for data exchange in this server mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA12x6RelBinaryTcpServerInputTrigger 1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.3
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, Bit 0-3: Digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Digital inputs 0-7
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelBinaryTcpServerApplicationMode 1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.4
Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 4-7: unused Bit 3 : OPC Device Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelBinaryTcpClientLocalPort 1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.5
Local TCP port for data exchange in this client mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA12x6RelBinaryTcpClientServerPort 1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.6
Port number of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server port to zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA12x6RelBinaryTcpClientServerIpAddr 1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.7
Ip address of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server IP address to 0.0.0.0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelBinaryTcpClientServerPassword 1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.8
Building a connection may be protected by the administrator password of the server. Enter the server password to establish the connection, if a server administrator password exists.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelBinaryTcpClientInactivity 1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.9
Connection timeout in 100ms. If no data are exchanged within the specified time, the device closes the connection to the server. The value 0 deactivates the timer. Using the Box2Box mode this function is disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelBinaryTcpClientInputTrigger 1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.10
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, Bit 0-3: Digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Digital inputs 0-7
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelBinaryTcpClientInterval 1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.11
Configurable interval with a 100ms base, in which the Webio device sends data to the configured application. A interval of zero stopps the periodical sending.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA12x6RelBinaryTcpClientApplicationMode 1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.12
Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelBinaryUdpPeerLocalPort 1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.13
Local UDP port for data exchange in this peer to peer mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA12x6RelBinaryUdpPeerRemotePort 1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.14
Port number of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote port to zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA12x6RelBinaryUdpPeerRemoteIpAddr 1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.15
Ip address of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote device IP address to 0.0.0.0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelBinaryUdpPeerInputTrigger 1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.16
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, Bit 0-3: Digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Digital inputs 0-7
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelBinaryUdpPeerInterval 1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.17
Configurable interval with a 100ms base, in which the Webio device sends data to the configured remote device. A interval of zero stopps the periodical sending.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA12x6RelBinaryUdpPeerApplicationMode 1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.18
Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelBinaryConnectedPort 1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.19
Port number of the remote device, after connection has been established. In case of no connection or missing port informations a zero will be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA12x6RelBinaryConnectedIpAddr 1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.20
IP address of the remote device, after connection has been established. In case of no connection or missing port informations 0.0.0.0 will be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

wtWebioEA12x6RelBinaryTcpServerClientHttpPort 1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.21
HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs status informations will be send to this port. Not used at mode Compatible 50xxx.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA12x6RelBinaryTcpClientServerHttpPort 1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.22
HTTP port number of the remote device at TCP Client Mode. In the operating mode Box2Box connection status informations will be exchanged through this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA12x6RelSyslogServerIP 1.3.6.1.4.1.5040.1.2.19.3.1.3.7.1
Name or IP address of the Syslog server, which accepts the Syslog messgaes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelSyslogServerPort 1.3.6.1.4.1.5040.1.2.19.3.1.3.7.2
Portnumber of the Syslog servers, default 514.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelSyslogSystemMessagesEnable 1.3.6.1.4.1.5040.1.2.19.3.1.3.7.3
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelSyslogEnable 1.3.6.1.4.1.5040.1.2.19.3.1.3.7.4
Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelFTPServerIP 1.3.6.1.4.1.5040.1.2.19.3.1.3.8.1
Name or IP address of the FTP server, which accepts the FTP messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelFTPServerControlPort 1.3.6.1.4.1.5040.1.2.19.3.1.3.8.2
Portnumber of the control port of the FTP server, default 21.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelFTPUserName 1.3.6.1.4.1.5040.1.2.19.3.1.3.8.3
FTP Loggin: user name.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelFTPPassword 1.3.6.1.4.1.5040.1.2.19.3.1.3.8.4
FTP Loggin: user password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelFTPAccount 1.3.6.1.4.1.5040.1.2.19.3.1.3.8.5
FTP Loggin: name of account.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelFTPOption 1.3.6.1.4.1.5040.1.2.19.3.1.3.8.6
Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelFTPEnable 1.3.6.1.4.1.5040.1.2.19.3.1.3.8.7
Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelOutputModeTable 1.3.6.1.4.1.5040.1.2.19.3.1.4.1
Table of output mode configurations dependent on the output indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA12x6RelOutputModeEntry

wtWebioEA12x6RelOutputModeEntry 1.3.6.1.4.1.5040.1.2.19.3.1.4.1.1
Output mode configurations of the individual outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA12x6RelOutputModeEntry  

wtWebioEA12x6RelOutputModeBit 1.3.6.1.4.1.5040.1.2.19.3.1.4.1.1.1
This binary coded output mode defines the individual operation mode for any output. More than one mode must not be selected. The OCTETS are interpreted bit-by-bit, with each set of octets corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 6-7: unused Bit 5 : Logic Bit 4 : Binary 2 Bit 3 : Binary 1 Bit 2 : SNMP Bit 1 : UDP ASCII Bit 0 : HTTP
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelSafetyTimeout 1.3.6.1.4.1.5040.1.2.19.3.1.4.2
After this period of time (multiple of 100ms) without receiving data outputs switch to their Safety States. For each output a independend safety state could be defined.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA12x6RelAlarmCount 1.3.6.1.4.1.5040.1.2.19.3.1.5.1
Number of independent alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..12  

wtWebioEA12x6RelAlarmIfTable 1.3.6.1.4.1.5040.1.2.19.3.1.5.2
List of alarm indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA12x6RelAlarmIfEntry

wtWebioEA12x6RelAlarmIfEntry 1.3.6.1.4.1.5040.1.2.19.3.1.5.2.1
Numbers of the alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA12x6RelAlarmIfEntry  

wtWebioEA12x6RelAlarmNo 1.3.6.1.4.1.5040.1.2.19.3.1.5.2.1.1
Numbers of the alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..12  

wtWebioEA12x6RelAlarmTable 1.3.6.1.4.1.5040.1.2.19.3.1.5.3
List of settings depending on the alarm number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA12x6RelAlarmEntry

wtWebioEA12x6RelAlarmEntry 1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1
Alarm parameters of the individual alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA12x6RelAlarmEntry  

wtWebioEA12x6RelAlarmInputTrigger 1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.1
This variable allows setting of individual input trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the inputs are to be considered (corresponding bit = 1) and which inputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3, Bit 0-3: Mask for digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Mask for digital inputs 0-7 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7, Bit 0-3: Level of digital inputs 8-11 Bit 4-7: unused OCTET 8, Bit 0-7: Level of digital inputs 0-7 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change of the corresponding input bit. Settings in OCTET 5-9 are then unused: OCTET 9 : unused OCTET 11, Bit 0-7 : ANY bits of digital inputs 8-11 Bit 12-15 : unused OCTET 12, Bit 0-7 : ANY bits of digital inputs 0-7
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(12)  

wtWebioEA12x6RelAlarmOutputTrigger 1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.2
This variable allows setting of individual output trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be considered (corresponding bit = 1) and which outputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-5: Mask for digital outputs 0-5 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-5: Level of digital outputs 0-5 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change of the corresponding output bit. Settings in OCTET 5-9 are then unused: OCTET 9 : unused OCTET 10: unused OCTET 11: unused OCTET 12: Bit 0-5: ANY bits of digital outputs 0-5
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(12)  

wtWebioEA12x6RelAlarmSystemTrigger 1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.3
Binary coded trigger conditions: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Warm Start Bit 2 : Cold Start Bit 1 : Timer Bit 0 : Load Control
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelAlarmMaxCounterValue 1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.4
This variable configures a max. counter value. If an input counter value exceeds this max. value, the corresponding alarm is triggered. Input counters with its mask bit unset in wtWebioEA12x6RelAlarmInputTrigger are not considered.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelAlarmInterval 1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.5
Send interval for alarm messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelAlarmEnable 1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.6
Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: UDP enable Bit 3: Send inputs to pending TCP connections Bit 4: TCP Client enable Bit 5: Syslog Messages enable Bit 6-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelAlarmMailAddr 1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.7
E-Mail address for sending the alarm mail to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelAlarmMailSubject 1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.8
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelAlarmMailText 1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.9
Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelAlarmSnmpManagerIP 1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.10
IP address of the SNMP Manager to which the Webio device should send SNMP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelAlarmSnmpTrapText 1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.11
This text appears in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelAlarmUdpIpAddr 1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.12
IP address of the UDP listener to which the Webio device should send UDP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelAlarmUdpPort 1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.13
Port number of the UDP listener to which the Webio device should send UDP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA12x6RelAlarmUdpText 1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.14
This text appears in the UDP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelAlarmTcpIpAddr 1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.15
IP address of the TCP listener to which the Webio device should send TCP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelAlarmTcpPort 1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.16
Port number of the TCP listener to which the Webio device should send TCP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA12x6RelAlarmTcpText 1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.17
This text appears in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelAlarmSyslogIpAddr 1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.18
IP address of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelAlarmSyslogPort 1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.19
Port number of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA12x6RelAlarmSyslogText 1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.20
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelAlarmFtpDataPort 1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.21
Local data port: 1..65535 or AUTO: the next free port will be assigned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelAlarmFtpFileName 1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.22
Name of the file including path informations.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelAlarmFtpText 1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.23
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelAlarmFtpOption 1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.24
Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelAlarmTimerCron 1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.25
This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelAlarmMailReleaseSubject 1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.26
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelAlarmMailReleaseText 1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.27
Release Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelAlarmSnmpTrapReleaseText 1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.28
This text appears in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelAlarmUdpReleaseText 1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.29
This text appears in the UDP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelAlarmTcpReleaseText 1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.30
This text appears in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelAlarmSyslogReleaseText 1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.31
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelAlarmFtpReleaseText 1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.32
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelInputPortTable 1.3.6.1.4.1.5040.1.2.19.3.2.1
List of settings depending on the input number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA12x6RelInputPortEntry

wtWebioEA12x6RelInputPortEntry 1.3.6.1.4.1.5040.1.2.19.3.2.1.1
Input parameter for the individual inputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA12x6RelInputPortEntry  

wtWebioEA12x6RelPortInputName 1.3.6.1.4.1.5040.1.2.19.3.2.1.1.1
Name of the input.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelPortInputText 1.3.6.1.4.1.5040.1.2.19.3.2.1.1.2
Description of the input.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelPortInputMode 1.3.6.1.4.1.5040.1.2.19.3.2.1.1.3
Binary coded modes: Selecting short pulse detection enable by setting the corresponding bit to 1 enables interrupt support for counting. Only positive edges are accepted as trigger source. The maximum counting frequenz equals 2000 Hz. This mode is available for inputs 0-3 only. Selecting counter clear on read by setting the corresponding bit to 1 enables the corresponding counter to be cleared automatically every time it is read, except HTTP reading with user rights. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. Selection for input 0-3: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 3-7: unused Bit 2 : Counter clear on read Bit 1 : Change detection enable (default) Bit 0 : Short Pulse detection enable Selection for inputs 4-11: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : Counter clear on read Bit 0 : Change detection enable (default)
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelPortInputFilter 1.3.6.1.4.1.5040.1.2.19.3.2.1.1.4
Pulses with a duration shorter than here specified (duration in 1/1000 sec), are ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelPortInputBicountPulsePolarity 1.3.6.1.4.1.5040.1.2.19.3.2.1.1.5
This value defines the polarity of the input pulse. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelPortInputBicountInactivTimeout 1.3.6.1.4.1.5040.1.2.19.3.2.1.1.6
Pulse chains with a duration shorter than here specified (in 1/10 sek), are ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelOutputPortTable 1.3.6.1.4.1.5040.1.2.19.3.2.2
List of settings depending on the output number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA12x6RelOutputPortEntry

wtWebioEA12x6RelOutputPortEntry 1.3.6.1.4.1.5040.1.2.19.3.2.2.1
Output parameters of the individual outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA12x6RelOutputPortEntry  

wtWebioEA12x6RelPortOutputName 1.3.6.1.4.1.5040.1.2.19.3.2.2.1.1
Name of the output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelPortOutputText 1.3.6.1.4.1.5040.1.2.19.3.2.2.1.2
Description of the output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelPortOutputGroupMode 1.3.6.1.4.1.5040.1.2.19.3.2.2.1.3
Unused in this device 57634
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelPortOutputSafetyState 1.3.6.1.4.1.5040.1.2.19.3.2.2.1.4
This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 1-7: unused Bit 0 : Mask for digital output OCTETS 5-8 contain the level (1=HIGH=Relais closed, 0=LOW Relais open) which the outputs to be changed should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 1-7: unused Bit 0 : Level of digital output
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelPortLogicInputMask 1.3.6.1.4.1.5040.1.2.19.3.2.2.1.5
Selecting one of these inputs by setting the corresponding bit to 1 enables the logic function for the output identified by the index within this table. The calculation take place in 4 steps: 1. Selecting inputs (wtWebioEA12x6RelPortLogicInputMask) 2. Inverting inputs if necessary (wtWebioEA12x6RelPortLogicInputInverter) 3. Logical combination (wtWebioEA12x6RelPortLogicFunction) 4. Inverting the result if necessary (wtWebioEA12x6RelPortLogicOutputInverter) OCTET 1: unused OCTET 2: unused OCTET 3: Bit 0-3 : inputs 8-11 Bit 4-7 : unused OCTET 4: Bit 0-7 : inputs 0-7
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelPortLogicInputInverter 1.3.6.1.4.1.5040.1.2.19.3.2.2.1.6
Every input bit selected here will be inverted. OCTET 1: unused OCTET 2: unused OCTET 3: Bit 0-3 : inputs 8-11 Bit 4-7 : unused OCTET 4: Bit 0-7 : inputs 0-7
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelPortLogicFunction 1.3.6.1.4.1.5040.1.2.19.3.2.2.1.7
This determines the logic function. No more than one function may be selected. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : logic function OR (default) Bit 1 : logic function AND Bit 2-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelPortLogicOutputInverter 1.3.6.1.4.1.5040.1.2.19.3.2.2.1.8
The logical operation result could be inverteted by setting the corresponding bit to 1. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : Output Inverter enable Bit 1-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelPortPulseDuration 1.3.6.1.4.1.5040.1.2.19.3.2.2.1.9
Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelPortPulsePolarity 1.3.6.1.4.1.5040.1.2.19.3.2.2.1.10
This value defines the polarity of the output pulse, if wtWebioEA12x6RelPortPulseDuration is not set to zero. After the pulse is finished, the output switches back to the opposite state. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelMfName 1.3.6.1.4.1.5040.1.2.19.3.3.1
Manufacturer company name
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelMfAddr 1.3.6.1.4.1.5040.1.2.19.3.3.2
Manufacturer address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelMfHotline 1.3.6.1.4.1.5040.1.2.19.3.3.3
Manufacturer hotline.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelMfInternet 1.3.6.1.4.1.5040.1.2.19.3.3.4
Manufacturer Internet address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelMfDeviceTyp 1.3.6.1.4.1.5040.1.2.19.3.3.5
Manufacturer device name (model number).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelMfOrderNo 1.3.6.1.4.1.5040.1.2.19.3.3.6
Manufacturer part number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelDiagErrorCount 1.3.6.1.4.1.5040.1.2.19.4.1
Number of entries in the error memory.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelDiagBinaryError 1.3.6.1.4.1.5040.1.2.19.4.2
Error causes coded bit-by-bit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelDiagErrorIndex 1.3.6.1.4.1.5040.1.2.19.4.3
The value of this variable is used as an index to read an error massege from wtWebioEA12x6RelDiagErrorMessage. Errors are numbered from 1 to wtWebioEA12x6RelDiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebioEA12x6RelDiagErrorMessage.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelDiagErrorMessage 1.3.6.1.4.1.5040.1.2.19.4.4
Using wtWebioEA12x6RelDiagErrorIndex as an index, the appropriate message is available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelDiagErrorClear 1.3.6.1.4.1.5040.1.2.19.4.5
Writing 1 into this variable clears all diagnosis messages.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelAlert1 41
This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelAlert2 42
This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelAlert3 43
This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelAlert4 44
This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelAlert5 45
This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelAlert6 46
This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelAlert7 47
This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelAlert8 48
This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelAlert9 49
This SNMP trap is generated when Alarm 9 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelAlert10 50
This SNMP trap is generated when Alarm 10 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelAlert11 51
This SNMP trap is generated when Alarm 11 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelAlert12 52
This SNMP trap is generated when Alarm 12 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelAlert13 71
This SNMP trap is generated when Alarm 1 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelAlert14 72
This SNMP trap is generated when Alarm 2 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelAlert15 73
This SNMP trap is generated when Alarm 3 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelAlert16 74
This SNMP trap is generated when Alarm 4 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelAlert17 75
This SNMP trap is generated when Alarm 5 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelAlert18 76
This SNMP trap is generated when Alarm 6 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelAlert19 77
This SNMP trap is generated when Alarm 7 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelAlert20 78
This SNMP trap is generated when Alarm 8 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelAlert21 79
This SNMP trap is generated when Alarm 9 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelAlert22 80
This SNMP trap is generated when Alarm 10 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelAlert23 81
This SNMP trap is generated when Alarm 11 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelAlert24 82
This SNMP trap is generated when Alarm 12 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelAlertDiag 110
This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Inputs 1.3.6.1.4.1.5040.1.2.20.1.1
Number of idependent inputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..6  

wtWebAlarm6x6Outputs 1.3.6.1.4.1.5040.1.2.20.1.2
Number of independent outputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..6  

wtWebAlarm6x6InputTable 1.3.6.1.4.1.5040.1.2.20.1.3
List of input indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebAlarm6x6InputEntry

wtWebAlarm6x6InputEntry 1.3.6.1.4.1.5040.1.2.20.1.3.1
Number of the inputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebAlarm6x6InputEntry  

wtWebAlarm6x6InputNo 1.3.6.1.4.1.5040.1.2.20.1.3.1.1
Index numbers of the inputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebAlarm6x6InputCounter 1.3.6.1.4.1.5040.1.2.20.1.3.1.2
Value of the input counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebAlarm6x6InputCounterClear 1.3.6.1.4.1.5040.1.2.20.1.3.1.3
Clears the input counter after returning its value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebAlarm6x6InputState 1.3.6.1.4.1.5040.1.2.20.1.3.1.4
States of the inputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtWebAlarm6x6InputState-OFF(0), wtWebAlarm6x6InputState-ON(1)  

wtWebAlarm6x6InputValue 1.3.6.1.4.1.5040.1.2.20.1.4
This variable is used to read the inputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-5: Digital inputs 0-5 Bit 6-7: unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebAlarm6x6OutputTable 1.3.6.1.4.1.5040.1.2.20.1.5
List of output indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebAlarm6x6OutputEntry

wtWebAlarm6x6OutputEntry 1.3.6.1.4.1.5040.1.2.20.1.5.1
Number of the outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebAlarm6x6OutputEntry  

wtWebAlarm6x6OutputNo 1.3.6.1.4.1.5040.1.2.20.1.5.1.1
Output number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebAlarm6x6OutputState 1.3.6.1.4.1.5040.1.2.20.1.5.1.2
States of the outputs.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebAlarm6x6OutputState-OFF(0), wtWebAlarm6x6OutputState-ON(1)  

wtWebAlarm6x6OutputValue 1.3.6.1.4.1.5040.1.2.20.1.6
This variable is used to read the outputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0-5: Digital outputs 0-5
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebAlarm6x6AlarmOutputTable 1.3.6.1.4.1.5040.1.2.20.1.8
List of alarm indices..
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebAlarm6x6AlarmOutputEntry

wtWebAlarm6x6AlarmOutputEntry 1.3.6.1.4.1.5040.1.2.20.1.8.1
Index reference.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebAlarm6x6AlarmOutputEntry  

wtWebAlarm6x6AlarmOutputState 1.3.6.1.4.1.5040.1.2.20.1.8.1.1
State of the alarm.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebAlarm6x6AlarmOutputState-OFF(0), wtWebAlarm6x6AlarmOutputState-ON(1)  

wtWebAlarm6x6AlarmTriggerState 1.3.6.1.4.1.5040.1.2.20.1.8.1.2
State of the trigger condition.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtWebAlarm6x6AlarmTriggerState-OFF(0), wtWebAlarm6x6AlarmTriggerState-ON(1)  

wtWebAlarm6x6SessCntrlPassword 1.3.6.1.4.1.5040.1.2.20.2.1
Entering this password opens a session which is ended by writing a 1 to wtWebAlarm6x6SessCntrlLogout. When read this variable provides a string of length zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6SessCntrlConfigMode 1.3.6.1.4.1.5040.1.2.20.2.2
When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtWebAlarm6x6SessCntrl-NoSession(0), wtWebAlarm6x6SessCntrl-Session(1)  

wtWebAlarm6x6SessCntrlLogout 1.3.6.1.4.1.5040.1.2.20.2.3
If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebAlarm6x6SessCntrlAdminPassword 1.3.6.1.4.1.5040.1.2.20.2.4
This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6SessCntrlConfigPassword 1.3.6.1.4.1.5040.1.2.20.2.5
This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6DeviceName 1.3.6.1.4.1.5040.1.2.20.3.1.1.1
Name of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6DeviceText 1.3.6.1.4.1.5040.1.2.20.3.1.1.2
Description of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6DeviceLocation 1.3.6.1.4.1.5040.1.2.20.3.1.1.3
Description of the location of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6DeviceContact 1.3.6.1.4.1.5040.1.2.20.3.1.1.4
Contact address of the system operator of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6TzOffsetHrs 1.3.6.1.4.1.5040.1.2.20.3.1.2.1.1
Offset hours for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebAlarm6x6TzOffsetMin 1.3.6.1.4.1.5040.1.2.20.3.1.2.1.2
Offset minutes for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebAlarm6x6TzEnable 1.3.6.1.4.1.5040.1.2.20.3.1.2.1.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebAlarm6x6StTzOffsetHrs 1.3.6.1.4.1.5040.1.2.20.3.1.2.1.4
Offset hours of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebAlarm6x6StTzOffsetMin 1.3.6.1.4.1.5040.1.2.20.3.1.2.1.5
Offset minutes of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebAlarm6x6StTzEnable 1.3.6.1.4.1.5040.1.2.20.3.1.2.1.6
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebAlarm6x6StTzStartMonth 1.3.6.1.4.1.5040.1.2.20.3.1.2.1.7
Month in which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebAlarm6x6StartMonth-January(1), wtWebAlarm6x6StartMonth-February(2), wtWebAlarm6x6StartMonth-March(3), wtWebAlarm6x6StartMonth-April(4), wtWebAlarm6x6StartMonth-May(5), wtWebAlarm6x6StartMonth-June(6), wtWebAlarm6x6StartMonth-July(7), wtWebAlarm6x6StartMonth-August(8), wtWebAlarm6x6StartMonth-September(9), wtWebAlarm6x6StartMonth-October(10), wtWebAlarm6x6StartMonth-November(11), wtWebAlarm6x6StartMonth-December(12)  

wtWebAlarm6x6StTzStartMode 1.3.6.1.4.1.5040.1.2.20.3.1.2.1.8
Mode of the day of the week for which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebAlarm6x6StartMode-first(1), wtWebAlarm6x6StartMode-second(2), wtWebAlarm6x6StartMode-third(3), wtWebAlarm6x6StartMode-fourth(4), wtWebAlarm6x6StartMode-last(5)  

wtWebAlarm6x6StTzStartWday 1.3.6.1.4.1.5040.1.2.20.3.1.2.1.9
Day of the week on which the change is made from winter time to summer time
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebAlarm6x6StartWday-Sunday(1), wtWebAlarm6x6StartWday-Monday(2), wtWebAlarm6x6StartWday-Tuesday(3), wtWebAlarm6x6StartWday-Thursday(4), wtWebAlarm6x6StartWday-Wednesday(5), wtWebAlarm6x6StartWday-Friday(6), wtWebAlarm6x6StartWday-Saturday(7)  

wtWebAlarm6x6StTzStartHrs 1.3.6.1.4.1.5040.1.2.20.3.1.2.1.10
Hour in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebAlarm6x6StTzStartMin 1.3.6.1.4.1.5040.1.2.20.3.1.2.1.11
Minute in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebAlarm6x6StTzStopMonth 1.3.6.1.4.1.5040.1.2.20.3.1.2.1.12
Month in which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebAlarm6x6StopMonth-January(1), wtWebAlarm6x6StopMonth-February(2), wtWebAlarm6x6StopMonth-March(3), wtWebAlarm6x6StopMonth-April(4), wtWebAlarm6x6StopMonth-May(5), wtWebAlarm6x6StopMonth-June(6), wtWebAlarm6x6StopMonth-July(7), wtWebAlarm6x6StopMonth-August(8), wtWebAlarm6x6StopMonth-September(9), wtWebAlarm6x6StopMonth-October(10), wtWebAlarm6x6StopMonth-November(11), wtWebAlarm6x6StopMonth-December(12)  

wtWebAlarm6x6StTzStopMode 1.3.6.1.4.1.5040.1.2.20.3.1.2.1.13
Mode of the week day on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebAlarm6x6StopMode-first(1), wtWebAlarm6x6StopMode-second(2), wtWebAlarm6x6StopMode-third(3), wtWebAlarm6x6StopMode-fourth(4), wtWebAlarm6x6StopMode-last(5)  

wtWebAlarm6x6StTzStopWday 1.3.6.1.4.1.5040.1.2.20.3.1.2.1.14
Day of the week on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebAlarm6x6StopWday-Sunday(1), wtWebAlarm6x6StopWday-Monday(2), wtWebAlarm6x6StopWday-Tuesday(3), wtWebAlarm6x6StopWday-Thursday(4), wtWebAlarm6x6StopWday-Wednesday(5), wtWebAlarm6x6StopWday-Friday(6), wtWebAlarm6x6StopWday-Saturday(7)  

wtWebAlarm6x6StTzStopHrs 1.3.6.1.4.1.5040.1.2.20.3.1.2.1.15
Hour at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebAlarm6x6StTzStopMin 1.3.6.1.4.1.5040.1.2.20.3.1.2.1.16
Minute at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebAlarm6x6TimeServer1 1.3.6.1.4.1.5040.1.2.20.3.1.2.2.1
IP address or name of the 1st time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6TimeServer2 1.3.6.1.4.1.5040.1.2.20.3.1.2.2.2
IP address or name of the 2nd time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6TsEnable 1.3.6.1.4.1.5040.1.2.20.3.1.2.2.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebAlarm6x6TsSyncTime 1.3.6.1.4.1.5040.1.2.20.3.1.2.2.4
Daily synchronisation time with the time server (hour: 0-23).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebAlarm6x6ClockHrs 1.3.6.1.4.1.5040.1.2.20.3.1.2.3.1
Clock hours taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..23  

wtWebAlarm6x6ClockMin 1.3.6.1.4.1.5040.1.2.20.3.1.2.3.2
Clock minutes taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..59  

wtWebAlarm6x6ClockDay 1.3.6.1.4.1.5040.1.2.20.3.1.2.3.3
Date: Day of the month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..31  

wtWebAlarm6x6ClockMonth 1.3.6.1.4.1.5040.1.2.20.3.1.2.3.4
Date: Month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebAlarm6x6ClockMonth-January(1), wtWebAlarm6x6ClockMonth-February(2), wtWebAlarm6x6ClockMonth-March(3), wtWebAlarm6x6ClockMonth-April(4), wtWebAlarm6x6ClockMonth-May(5), wtWebAlarm6x6ClockMonth-June(6), wtWebAlarm6x6ClockMonth-July(7), wtWebAlarm6x6ClockMonth-August(8), wtWebAlarm6x6ClockMonth-September(9), wtWebAlarm6x6ClockMonth-October(10), wtWebAlarm6x6ClockMonth-November(11), wtWebAlarm6x6ClockMonth-December(12)  

wtWebAlarm6x6ClockYear 1.3.6.1.4.1.5040.1.2.20.3.1.2.3.5
Date: Year, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebAlarm6x6IpAddress 1.3.6.1.4.1.5040.1.2.20.3.1.3.1.1
IP address of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebAlarm6x6SubnetMask 1.3.6.1.4.1.5040.1.2.20.3.1.3.1.2
Subnet mask of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebAlarm6x6Gateway 1.3.6.1.4.1.5040.1.2.20.3.1.3.1.3
Gateway of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebAlarm6x6DnsServer1 1.3.6.1.4.1.5040.1.2.20.3.1.3.1.4
IP address of the 1st DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6DnsServer2 1.3.6.1.4.1.5040.1.2.20.3.1.3.1.5
IP address of the 2nd DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AddConfig 1.3.6.1.4.1.5040.1.2.20.3.1.3.1.6
Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP enable Bit 0: BOOTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6HttpPort 1.3.6.1.4.1.5040.1.2.20.3.1.3.2.4
Definition of the standard HTML port (Default: 80).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65534  

wtWebAlarm6x6MailAdName 1.3.6.1.4.1.5040.1.2.20.3.1.3.3.1
Device name for mail administration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6MailReply 1.3.6.1.4.1.5040.1.2.20.3.1.3.3.2
Reply address for the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6MailServer 1.3.6.1.4.1.5040.1.2.20.3.1.3.3.3
Name or IP address of the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6MailEnable 1.3.6.1.4.1.5040.1.2.20.3.1.3.3.4
Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6MailAuthentication 1.3.6.1.4.1.5040.1.2.20.3.1.3.3.5
Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebAlarm6x6MailAuthUser 1.3.6.1.4.1.5040.1.2.20.3.1.3.3.6
Name of the user to be authenticated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6MailAuthPassword 1.3.6.1.4.1.5040.1.2.20.3.1.3.3.7
Authentication password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6MailPop3Server 1.3.6.1.4.1.5040.1.2.20.3.1.3.3.8
Name or Ip-address of the POP3 Servers.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6SnmpEnable 1.3.6.1.4.1.5040.1.2.20.3.1.3.4.1
Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6SnmpCommunityStringRead 1.3.6.1.4.1.5040.1.2.20.3.1.3.4.2
Community string read only
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6SnmpCommunityStringReadWrite 1.3.6.1.4.1.5040.1.2.20.3.1.3.4.3
Community string read / write
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6SnmpSystemTrapManagerIP 1.3.6.1.4.1.5040.1.2.20.3.1.3.4.4
Name or IP address of the TCP server which accepts the system trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6SnmpSystemTrapEnable 1.3.6.1.4.1.5040.1.2.20.3.1.3.4.5
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag messages Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebAlarm6x6UdpAdminPort 1.3.6.1.4.1.5040.1.2.20.3.1.3.5.1
Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebAlarm6x6UdpEnable 1.3.6.1.4.1.5040.1.2.20.3.1.3.5.2
Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6UdpRemotePort 1.3.6.1.4.1.5040.1.2.20.3.1.3.5.3
Udp remote port setting. If this value is set to zero, the source port read from a request will be used as destination port for the answer. A non zero value forced the destination port to this value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebAlarm6x6SyslogServerIP 1.3.6.1.4.1.5040.1.2.20.3.1.3.7.1
Name or IP address of the Syslog server, which accepts the Syslog messgaes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6SyslogServerPort 1.3.6.1.4.1.5040.1.2.20.3.1.3.7.2
Portnumber of the Syslog servers, default 514.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebAlarm6x6SyslogSystemMessagesEnable 1.3.6.1.4.1.5040.1.2.20.3.1.3.7.3
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebAlarm6x6SyslogEnable 1.3.6.1.4.1.5040.1.2.20.3.1.3.7.4
Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6FTPServerIP 1.3.6.1.4.1.5040.1.2.20.3.1.3.8.1
Name or IP address of the FTP server, which accepts the FTP messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6FTPServerControlPort 1.3.6.1.4.1.5040.1.2.20.3.1.3.8.2
Portnumber of the control port of the FTP server, default 21.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebAlarm6x6FTPUserName 1.3.6.1.4.1.5040.1.2.20.3.1.3.8.3
FTP Loggin: user name.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6FTPPassword 1.3.6.1.4.1.5040.1.2.20.3.1.3.8.4
FTP Loggin: user password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6FTPAccount 1.3.6.1.4.1.5040.1.2.20.3.1.3.8.5
FTP Loggin: name of account.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6FTPOption 1.3.6.1.4.1.5040.1.2.20.3.1.3.8.6
Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6FTPEnable 1.3.6.1.4.1.5040.1.2.20.3.1.3.8.7
Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmCount 1.3.6.1.4.1.5040.1.2.20.3.1.5.1
Number of independent alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..12  

wtWebAlarm6x6AlarmIfTable 1.3.6.1.4.1.5040.1.2.20.3.1.5.2
List of alarm indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebAlarm6x6AlarmIfEntry

wtWebAlarm6x6AlarmIfEntry 1.3.6.1.4.1.5040.1.2.20.3.1.5.2.1
Numbers of the alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebAlarm6x6AlarmIfEntry  

wtWebAlarm6x6AlarmNo 1.3.6.1.4.1.5040.1.2.20.3.1.5.2.1.1
Numbers of the alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..12  

wtWebAlarm6x6AlarmTable 1.3.6.1.4.1.5040.1.2.20.3.1.5.3
List of settings depending on the alarm number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebAlarm6x6AlarmEntry

wtWebAlarm6x6AlarmEntry 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1
Alarm parameters of the individual alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebAlarm6x6AlarmEntry  

wtWebAlarm6x6AlarmInputTrigger 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.1
This variable allows setting of individual input trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the inputs are to be considered (corresponding bit = 1) and which inputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3: unused OCTET 4, Bit 0-5: Mask for digital inputs 0-5 Bit 6-7: unused OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-5: Level of digital inputs 0-5 Bit 6-7: unused OCTETS 9-12 contain the counter bit (1=ON, 0=OFF). Inputs masked with the counter bit trigger an alarm when the corresponding counter reaching the wtWebAlarm6x6AlarmMaxCounterValue. Settings in OCTET 5-9 are then unused: OCTET 9 : unused OCTET 10: unused OCTET 11: unused OCTET 12, Bit 0-5: Counter bits of digital inputs 0-5 Bit 6-7: unused.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(12)  

wtWebAlarm6x6AlarmMaxCounterValue 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.4
This variable configures a max. counter value. If an input counter value exceeds this max. value, the corresponding alarm is triggered. Input counters with its mask bit unset in wtWebAlarm6x6AlarmInputTrigger are not considered.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmInterval 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.5
Send interval for alarm messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmEnable 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.6
Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Output Switch Enable Bit 1: Mail Enable Bit 2: SNMP Trap enable Bit 3: UDP enable Bit 4: unused Bit 5: TCP Client enable Bit 6: Syslog Messages enable Bit 7: FTP Client enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebAlarm6x6AlarmMailAddr 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.7
E-Mail address for sending the alarm mail to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmMailSubject 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.8
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmMailText 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.9
Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmSnmpManagerIP 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.10
IP address of the SNMP Manager to which the Webio device should send SNMP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmSnmpTrapText 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.11
This text appears in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmUdpIpAddr 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.12
IP address of the UDP listener to which the Webio device should send UDP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmUdpPort 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.13
Port number of the UDP listener to which the Webio device should send UDP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebAlarm6x6AlarmUdpText 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.14
This text appears in the UDP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmTcpIpAddr 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.15
IP address of the TCP listener to which the Webio device should send TCP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmTcpPort 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.16
Port number of the TCP listener to which the Webio device should send TCP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebAlarm6x6AlarmTcpText 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.17
This text appears in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmSyslogIpAddr 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.18
IP address of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmSyslogPort 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.19
Port number of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebAlarm6x6AlarmSyslogText 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.20
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmFtpDataPort 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.21
Local data port: 1..65535 or AUTO: the next free port will be assigned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmFtpFileName 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.22
Name of the file including path informations.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmFtpText 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.23
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmFtpOption 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.24
Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebAlarm6x6AlarmMailReleaseSubject 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.26
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmMailReleaseText 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.27
Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmSnmpTrapReleaseText 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.28
This text appears in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmUdpReleaseText 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.29
This text appears in the UDP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmTcpReleaseText 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.30
This text appears in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmSyslogReleaseText 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.31
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmFtpReleaseText 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.32
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmName 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.33
Name of the alarm.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmGlobalEnable 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.34
Binary coded alarm activation: Die OCTETS werden bitweise interpretiert. Bit 0 entspricht dem LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : Alarm enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmCounterClear 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.35
Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : Counter clear on Alarm acknowledge Bit 0 : Counter clear on Alarm send
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmAckEnable 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.36
Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : Software acknowledge enable Bit 0 : Hardware acknowledge enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmAckPort 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.37
Number of the input, which clears the alarm (1-6).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebAlarm6x6AlarmSetPort 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.38
Number of the output, which will be set by this alarm (1-6). The configuration of pulse mode and polarity defined in the port output section is used.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebAlarm6x6AlarmMailTrgClearSubject 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.39
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmMailTrgClearText 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.40
Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmSnmpTrapTrgClearText 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.41
This text appears in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmUdpTrgClearText 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.42
This text appears in the UDP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmTcpTrgClearText 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.43
This text appears in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmSyslogTrgClearText 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.44
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmFtpTrgClearText 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.45
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmMailTrapTxEnable 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.46
Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmSnmpTrapTrapTxEnable 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.47
Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmUdpTrapTxEnable 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.48
Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmTcpTrapTxEnable 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.49
Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmSyslogTrapTxEnable 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.50
Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6AlarmFtpTrapTxEnable 1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.51
Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6InputPortTable 1.3.6.1.4.1.5040.1.2.20.3.2.1
List of settings depending on the input number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebAlarm6x6InputPortEntry

wtWebAlarm6x6InputPortEntry 1.3.6.1.4.1.5040.1.2.20.3.2.1.1
Input parameter for the individual inputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebAlarm6x6InputPortEntry  

wtWebAlarm6x6PortInputName 1.3.6.1.4.1.5040.1.2.20.3.2.1.1.1
Name of the input.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6PortInputText 1.3.6.1.4.1.5040.1.2.20.3.2.1.1.2
Description of the input.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6PortInputFilter 1.3.6.1.4.1.5040.1.2.20.3.2.1.1.4
Pulses with a duration shorter than here specified (duration in 1/1000 sec), are ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebAlarm6x6PortInputPulsePolarity 1.3.6.1.4.1.5040.1.2.20.3.2.1.1.5
This value defines the polarity of the input pulse. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebAlarm6x6PortInputCounterSet 1.3.6.1.4.1.5040.1.2.20.3.2.1.1.7
Writing to this variable presets the counter, while reading returns the actual value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebAlarm6x6OutputPortTable 1.3.6.1.4.1.5040.1.2.20.3.2.2
List of settings depending on the output number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebAlarm6x6OutputPortEntry

wtWebAlarm6x6OutputPortEntry 1.3.6.1.4.1.5040.1.2.20.3.2.2.1
Output parameters of the individual outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebAlarm6x6OutputPortEntry  

wtWebAlarm6x6PortOutputName 1.3.6.1.4.1.5040.1.2.20.3.2.2.1.1
Name of the output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6PortOutputText 1.3.6.1.4.1.5040.1.2.20.3.2.2.1.2
Description of the output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6PortPulseDuration 1.3.6.1.4.1.5040.1.2.20.3.2.2.1.9
Pulse length in 1/100 sec. Setting this value to zero, disables the pulse output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebAlarm6x6PortPulsePolarity 1.3.6.1.4.1.5040.1.2.20.3.2.2.1.10
This value defines the polarity of the output pulse, if wtWebAlarm6x6PortPulseDuration is not set to zero. After the pulse is finished, the output switches back to the opposite state. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebAlarm6x6MfName 1.3.6.1.4.1.5040.1.2.20.3.3.1
Manufacturer company name
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6MfAddr 1.3.6.1.4.1.5040.1.2.20.3.3.2
Manufacturer address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6MfHotline 1.3.6.1.4.1.5040.1.2.20.3.3.3
Manufacturer hotline.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6MfInternet 1.3.6.1.4.1.5040.1.2.20.3.3.4
Manufacturer Internet address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6MfDeviceTyp 1.3.6.1.4.1.5040.1.2.20.3.3.5
Manufacturer device name (model number).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6MfOrderNo 1.3.6.1.4.1.5040.1.2.20.3.3.6
Manufacturer part number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6DiagErrorCount 1.3.6.1.4.1.5040.1.2.20.4.1
Number of entries in the error memory.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebAlarm6x6DiagBinaryError 1.3.6.1.4.1.5040.1.2.20.4.2
Error causes coded bit-by-bit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6DiagErrorIndex 1.3.6.1.4.1.5040.1.2.20.4.3
The value of this variable is used as an index to read an error massege from wtWebAlarm6x6DiagErrorMessage. Errors are numbered from 1 to wtWebAlarm6x6DiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebAlarm6x6DiagErrorMessage.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebAlarm6x6DiagErrorMessage 1.3.6.1.4.1.5040.1.2.20.4.4
Using wtWebAlarm6x6DiagErrorIndex as an index, the appropriate message is available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebAlarm6x6DiagErrorClear 1.3.6.1.4.1.5040.1.2.20.4.5
Writing 1 into this variable clears all diagnosis messages.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER  

wtWebAlarm6x6Alert1 41
This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert2 42
This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert3 43
This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert4 44
This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert5 45
This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert6 46
This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert7 47
This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert8 48
This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert9 49
This SNMP trap is generated when Alarm 9 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert10 50
This SNMP trap is generated when Alarm 10 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert11 51
This SNMP trap is generated when Alarm 11 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert12 52
This SNMP trap is generated when Alarm 12 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert13 71
This SNMP trap is generated when Alarm 1 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert14 72
This SNMP trap is generated when Alarm 2 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert15 73
This SNMP trap is generated when Alarm 3 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert16 74
This SNMP trap is generated when Alarm 4 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert17 75
This SNMP trap is generated when Alarm 5 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert18 76
This SNMP trap is generated when Alarm 6 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert19 77
This SNMP trap is generated when Alarm 7 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert20 78
This SNMP trap is generated when Alarm 8 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert21 79
This SNMP trap is generated when Alarm 9 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert22 80
This SNMP trap is generated when Alarm 10 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert23 81
This SNMP trap is generated when Alarm 11 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert24 82
This SNMP trap is generated when Alarm 12 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert25 91
This SNMP trap is generated when the trigger of the Alarm 1 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert26 92
This SNMP trap is generated when the trigger of the Alarm 2 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert27 93
This SNMP trap is generated when the trigger of the Alarm 3 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert28 94
This SNMP trap is generated when the trigger of the Alarm 4 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert29 95
This SNMP trap is generated when the trigger of the Alarm 5 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert30 96
This SNMP trap is generated when the trigger of the Alarm 6 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert31 97
This SNMP trap is generated when the trigger of the Alarm 7 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert32 98
This SNMP trap is generated when the trigger of the Alarm 8 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert33 99
This SNMP trap is generated when the trigger of the Alarm 9 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert34 100
This SNMP trap is generated when the trigger of the Alarm 10 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert35 101
This SNMP trap is generated when the trigger of the Alarm 11 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6Alert36 102
This SNMP trap is generated when the trigger of the Alarm 12 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebAlarm6x6AlertDiag 110
This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebCount6Inputs 1.3.6.1.4.1.5040.1.2.22.1.1
Number of idependent inputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..6  

wtWebCount6Outputs 1.3.6.1.4.1.5040.1.2.22.1.2
Number of independent outputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..6  

wtWebCount6InputTable 1.3.6.1.4.1.5040.1.2.22.1.3
List of input indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebCount6InputEntry

wtWebCount6InputEntry 1.3.6.1.4.1.5040.1.2.22.1.3.1
Number of the inputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebCount6InputEntry  

wtWebCount6InputNo 1.3.6.1.4.1.5040.1.2.22.1.3.1.1
Index numbers of the inputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebCount6InputCounter 1.3.6.1.4.1.5040.1.2.22.1.3.1.2
Value of the input counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebCount6InputCounterClear 1.3.6.1.4.1.5040.1.2.22.1.3.1.3
Clears the input counter after returning its value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebCount6InputState 1.3.6.1.4.1.5040.1.2.22.1.3.1.4
Tates of the inputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtWebCount6InputState-OFF(0), wtWebCount6InputState-ON(1)  

wtWebCount6InputValue 1.3.6.1.4.1.5040.1.2.22.1.4
This variable is used to read the inputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-5: Digital inputs 0-5 Bit 6-7: unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebCount6ReportOutputTable 1.3.6.1.4.1.5040.1.2.22.1.8
List of Report indices..
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebCount6ReportOutputEntry

wtWebCount6ReportOutputEntry 1.3.6.1.4.1.5040.1.2.22.1.8.1
Index reference.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebCount6ReportOutputEntry  

wtWebCount6ReportOutputState 1.3.6.1.4.1.5040.1.2.22.1.8.1.1
State of the Report.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebCount6ReportOutputState-OFF(0), wtWebCount6ReportOutputState-ON(1)  

wtWebCount6ReportTriggerState 1.3.6.1.4.1.5040.1.2.22.1.8.1.2
State of the trigger condition.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtWebCount6ReportTriggerState-OFF(0), wtWebCount6ReportTriggerState-ON(1)  

wtWebCount6SessCntrlPassword 1.3.6.1.4.1.5040.1.2.22.2.1
Entering this password opens a session which is ended by writing a 1 to wtWebCount6SessCntrlLogout. When read this variable provides a string of length zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6SessCntrlConfigMode 1.3.6.1.4.1.5040.1.2.22.2.2
When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtWebCount6SessCntrl-NoSession(0), wtWebCount6SessCntrl-Session(1)  

wtWebCount6SessCntrlLogout 1.3.6.1.4.1.5040.1.2.22.2.3
If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebCount6SessCntrlAdminPassword 1.3.6.1.4.1.5040.1.2.22.2.4
This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6SessCntrlConfigPassword 1.3.6.1.4.1.5040.1.2.22.2.5
This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6DeviceName 1.3.6.1.4.1.5040.1.2.22.3.1.1.1
Name of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6DeviceText 1.3.6.1.4.1.5040.1.2.22.3.1.1.2
Description of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6DeviceLocation 1.3.6.1.4.1.5040.1.2.22.3.1.1.3
Description of the location of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6DeviceContact 1.3.6.1.4.1.5040.1.2.22.3.1.1.4
Contact address of the system operator of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6TzOffsetHrs 1.3.6.1.4.1.5040.1.2.22.3.1.2.1.1
Offset hours for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebCount6TzOffsetMin 1.3.6.1.4.1.5040.1.2.22.3.1.2.1.2
Offset minutes for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebCount6TzEnable 1.3.6.1.4.1.5040.1.2.22.3.1.2.1.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebCount6StTzOffsetHrs 1.3.6.1.4.1.5040.1.2.22.3.1.2.1.4
Offset hours of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebCount6StTzOffsetMin 1.3.6.1.4.1.5040.1.2.22.3.1.2.1.5
Offset minutes of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebCount6StTzEnable 1.3.6.1.4.1.5040.1.2.22.3.1.2.1.6
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebCount6StTzStartMonth 1.3.6.1.4.1.5040.1.2.22.3.1.2.1.7
Month in which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebCount6StartMonth-January(1), wtWebCount6StartMonth-February(2), wtWebCount6StartMonth-March(3), wtWebCount6StartMonth-April(4), wtWebCount6StartMonth-May(5), wtWebCount6StartMonth-June(6), wtWebCount6StartMonth-July(7), wtWebCount6StartMonth-August(8), wtWebCount6StartMonth-September(9), wtWebCount6StartMonth-October(10), wtWebCount6StartMonth-November(11), wtWebCount6StartMonth-December(12)  

wtWebCount6StTzStartMode 1.3.6.1.4.1.5040.1.2.22.3.1.2.1.8
Mode of the day of the week for which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebCount6StartMode-first(1), wtWebCount6StartMode-second(2), wtWebCount6StartMode-third(3), wtWebCount6StartMode-fourth(4), wtWebCount6StartMode-last(5)  

wtWebCount6StTzStartWday 1.3.6.1.4.1.5040.1.2.22.3.1.2.1.9
Day of the week on which the change is made from winter time to summer time
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebCount6StartWday-Sunday(1), wtWebCount6StartWday-Monday(2), wtWebCount6StartWday-Tuesday(3), wtWebCount6StartWday-Thursday(4), wtWebCount6StartWday-Wednesday(5), wtWebCount6StartWday-Friday(6), wtWebCount6StartWday-Saturday(7)  

wtWebCount6StTzStartHrs 1.3.6.1.4.1.5040.1.2.22.3.1.2.1.10
Hour in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebCount6StTzStartMin 1.3.6.1.4.1.5040.1.2.22.3.1.2.1.11
Minute in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebCount6StTzStopMonth 1.3.6.1.4.1.5040.1.2.22.3.1.2.1.12
Month in which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebCount6StopMonth-January(1), wtWebCount6StopMonth-February(2), wtWebCount6StopMonth-March(3), wtWebCount6StopMonth-April(4), wtWebCount6StopMonth-May(5), wtWebCount6StopMonth-June(6), wtWebCount6StopMonth-July(7), wtWebCount6StopMonth-August(8), wtWebCount6StopMonth-September(9), wtWebCount6StopMonth-October(10), wtWebCount6StopMonth-November(11), wtWebCount6StopMonth-December(12)  

wtWebCount6StTzStopMode 1.3.6.1.4.1.5040.1.2.22.3.1.2.1.13
Mode of the week day on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebCount6StopMode-first(1), wtWebCount6StopMode-second(2), wtWebCount6StopMode-third(3), wtWebCount6StopMode-fourth(4), wtWebCount6StopMode-last(5)  

wtWebCount6StTzStopWday 1.3.6.1.4.1.5040.1.2.22.3.1.2.1.14
Day of the week on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebCount6StopWday-Sunday(1), wtWebCount6StopWday-Monday(2), wtWebCount6StopWday-Tuesday(3), wtWebCount6StopWday-Thursday(4), wtWebCount6StopWday-Wednesday(5), wtWebCount6StopWday-Friday(6), wtWebCount6StopWday-Saturday(7)  

wtWebCount6StTzStopHrs 1.3.6.1.4.1.5040.1.2.22.3.1.2.1.15
Hour at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebCount6StTzStopMin 1.3.6.1.4.1.5040.1.2.22.3.1.2.1.16
Minute at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebCount6TimeServer1 1.3.6.1.4.1.5040.1.2.22.3.1.2.2.1
IP address or name of the 1st time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6TimeServer2 1.3.6.1.4.1.5040.1.2.22.3.1.2.2.2
IP address or name of the 2nd time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6TsEnable 1.3.6.1.4.1.5040.1.2.22.3.1.2.2.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebCount6TsSyncTime 1.3.6.1.4.1.5040.1.2.22.3.1.2.2.4
Daily synchronisation time with the time server (hour: 0-23).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebCount6ClockHrs 1.3.6.1.4.1.5040.1.2.22.3.1.2.3.1
Clock hours taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..23  

wtWebCount6ClockMin 1.3.6.1.4.1.5040.1.2.22.3.1.2.3.2
Clock minutes taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..59  

wtWebCount6ClockDay 1.3.6.1.4.1.5040.1.2.22.3.1.2.3.3
Date: Day of the month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..31  

wtWebCount6ClockMonth 1.3.6.1.4.1.5040.1.2.22.3.1.2.3.4
Date: Month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebCount6ClockMonth-January(1), wtWebCount6ClockMonth-February(2), wtWebCount6ClockMonth-March(3), wtWebCount6ClockMonth-April(4), wtWebCount6ClockMonth-May(5), wtWebCount6ClockMonth-June(6), wtWebCount6ClockMonth-July(7), wtWebCount6ClockMonth-August(8), wtWebCount6ClockMonth-September(9), wtWebCount6ClockMonth-October(10), wtWebCount6ClockMonth-November(11), wtWebCount6ClockMonth-December(12)  

wtWebCount6ClockYear 1.3.6.1.4.1.5040.1.2.22.3.1.2.3.5
Date: Year, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebCount6IpAddress 1.3.6.1.4.1.5040.1.2.22.3.1.3.1.1
IP address of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebCount6SubnetMask 1.3.6.1.4.1.5040.1.2.22.3.1.3.1.2
Subnet mask of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebCount6Gateway 1.3.6.1.4.1.5040.1.2.22.3.1.3.1.3
Gateway of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebCount6DnsServer1 1.3.6.1.4.1.5040.1.2.22.3.1.3.1.4
IP address of the 1st DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6DnsServer2 1.3.6.1.4.1.5040.1.2.22.3.1.3.1.5
IP address of the 2nd DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6AddConfig 1.3.6.1.4.1.5040.1.2.22.3.1.3.1.6
Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP enable Bit 0: BOOTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6HttpPort 1.3.6.1.4.1.5040.1.2.22.3.1.3.2.4
Definition of the standard HTML port (Default: 80).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65534  

wtWebCount6MailAdName 1.3.6.1.4.1.5040.1.2.22.3.1.3.3.1
Device name for mail administration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6MailReply 1.3.6.1.4.1.5040.1.2.22.3.1.3.3.2
Reply address for the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6MailServer 1.3.6.1.4.1.5040.1.2.22.3.1.3.3.3
Name or IP address of the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6MailEnable 1.3.6.1.4.1.5040.1.2.22.3.1.3.3.4
Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6MailAuthentication 1.3.6.1.4.1.5040.1.2.22.3.1.3.3.5
Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebCount6MailAuthUser 1.3.6.1.4.1.5040.1.2.22.3.1.3.3.6
Name of the user to be authenticated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6MailAuthPassword 1.3.6.1.4.1.5040.1.2.22.3.1.3.3.7
Authentication password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6MailPop3Server 1.3.6.1.4.1.5040.1.2.22.3.1.3.3.8
Name or Ip-address of the POP3 Servers.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6SnmpEnable 1.3.6.1.4.1.5040.1.2.22.3.1.3.4.1
Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6SnmpCommunityStringRead 1.3.6.1.4.1.5040.1.2.22.3.1.3.4.2
Community string read only
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6SnmpCommunityStringReadWrite 1.3.6.1.4.1.5040.1.2.22.3.1.3.4.3
Community string read / write
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6SnmpSystemTrapManagerIP 1.3.6.1.4.1.5040.1.2.22.3.1.3.4.4
Name or IP address of the TCP server which accepts the system trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6SnmpSystemTrapEnable 1.3.6.1.4.1.5040.1.2.22.3.1.3.4.5
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag messages Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebCount6UdpAdminPort 1.3.6.1.4.1.5040.1.2.22.3.1.3.5.1
Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebCount6UdpEnable 1.3.6.1.4.1.5040.1.2.22.3.1.3.5.2
Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6UdpRemotePort 1.3.6.1.4.1.5040.1.2.22.3.1.3.5.3
Udp remote port setting. If this value is set to zero, the source port read from a request will be used as destination port for the answer. A non zero value forced the destination port to this value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebCount6SyslogServerIP 1.3.6.1.4.1.5040.1.2.22.3.1.3.7.1
Name or IP address of the Syslog server, which accepts the Syslog messgaes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6SyslogServerPort 1.3.6.1.4.1.5040.1.2.22.3.1.3.7.2
Portnumber of the Syslog servers, default 514.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebCount6SyslogSystemMessagesEnable 1.3.6.1.4.1.5040.1.2.22.3.1.3.7.3
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebCount6SyslogEnable 1.3.6.1.4.1.5040.1.2.22.3.1.3.7.4
Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6FTPServerIP 1.3.6.1.4.1.5040.1.2.22.3.1.3.8.1
Name or IP address of the FTP server, which accepts the FTP messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6FTPServerControlPort 1.3.6.1.4.1.5040.1.2.22.3.1.3.8.2
Portnumber of the control port of the FTP server, default 21.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebCount6FTPUserName 1.3.6.1.4.1.5040.1.2.22.3.1.3.8.3
FTP Loggin: user name.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6FTPPassword 1.3.6.1.4.1.5040.1.2.22.3.1.3.8.4
FTP Loggin: user password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6FTPAccount 1.3.6.1.4.1.5040.1.2.22.3.1.3.8.5
FTP Loggin: name of account.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6FTPOption 1.3.6.1.4.1.5040.1.2.22.3.1.3.8.6
Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6FTPEnable 1.3.6.1.4.1.5040.1.2.22.3.1.3.8.7
Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6ReportCount 1.3.6.1.4.1.5040.1.2.22.3.1.5.1
Number of independent Reports.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..12  

wtWebCount6ReportIfTable 1.3.6.1.4.1.5040.1.2.22.3.1.5.2
List of Report indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebCount6ReportIfEntry

wtWebCount6ReportIfEntry 1.3.6.1.4.1.5040.1.2.22.3.1.5.2.1
Numbers of the Reports.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebCount6ReportIfEntry  

wtWebCount6ReportNo 1.3.6.1.4.1.5040.1.2.22.3.1.5.2.1.1
Numbers of the Reports.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..12  

wtWebCount6ReportTable 1.3.6.1.4.1.5040.1.2.22.3.1.5.3
List of settings depending on the Report number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebCount6ReportEntry

wtWebCount6ReportEntry 1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1
Report parameters of the individual Reports.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebCount6ReportEntry  

wtWebCount6ReportInputTrigger 1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.1
This variable allows setting of individual input trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the inputs are to be considered (corresponding bit = 1) and which inputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3: unused OCTET 4, Bit 0-5: Mask for digital inputs 0-5 Bit 6-7: unused OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-5: Level of digital inputs 0-5 Bit 6-7: unused OCTETS 9-12 contain the counter bit (1=ON, 0=OFF). Inputs masked with the counter bit trigger an Report when the corresponding counter reaching the wtWebCount6ReportMaxCounterValue. Settings in OCTET 5-9 are then unused: OCTET 9 : unused OCTET 10: unused OCTET 11: unused OCTET 12, Bit 0-5: Counter bits of digital inputs 0-5 Bit 6-7: unused.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(12)  

wtWebCount6ReportSystemTrigger 1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.3
Binary coded trigger conditions: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 7 : Timer OFF Bit 6 : Time Window Bit 5 : unused Bit 4 : unused Bit 3 : unused Bit 2 : unused Bit 1 : Timer Bit 0 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6ReportMaxCounterValue 1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.4
This variable configures a max. counter value. If an input counter value exceeds this max. value, the corresponding Report is triggered. Input counters with its mask bit unset in wtWebCount6ReportInputTrigger are not considered.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6ReportInterval 1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.5
Send interval for Report messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6ReportEnable 1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.6
Binary coded Report enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Output Switch Enable Bit 1: Mail Enable Bit 2: SNMP Trap enable Bit 3: UDP enable Bit 4: unused Bit 5: TCP Client enable Bit 6: Syslog Messages enable Bit 7: FTP Client enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebCount6ReportMailAddr 1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.7
E-Mail address for sending the Report mail to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6ReportMailSubject 1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.8
Subject line for Report mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6ReportMailText 1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.9
Report mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6ReportSnmpManagerIP 1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.10
IP address of the SNMP Manager to which the Webio device should send SNMP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6ReportSnmpTrapText 1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.11
This text appears in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6ReportUdpIpAddr 1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.12
IP address of the UDP listener to which the Webio device should send UDP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6ReportUdpPort 1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.13
Port number of the UDP listener to which the Webio device should send UDP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebCount6ReportUdpText 1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.14
This text appears in the UDP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6ReportTcpIpAddr 1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.15
IP address of the TCP listener to which the Webio device should send TCP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6ReportTcpPort 1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.16
Port number of the TCP listener to which the Webio device should send TCP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebCount6ReportTcpText 1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.17
This text appears in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6ReportSyslogIpAddr 1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.18
IP address of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6ReportSyslogPort 1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.19
Port number of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebCount6ReportSyslogText 1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.20
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6ReportFtpDataPort 1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.21
Local data port: 1..65535 or AUTO: the next free port will be assigned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6ReportFtpFileName 1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.22
Name of the file including path informations.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6ReportFtpText 1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.23
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6ReportFtpOption 1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.24
Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebCount6ReportTimerCron 1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.25
This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a report, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6ReportName 1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.33
Name of the Report.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6ReportGlobalEnable 1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.34
Binary coded Report activation: Die OCTETS werden bitweise interpretiert. Bit 0 entspricht dem LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : Report enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6ReportCounterClear 1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.35
Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : Counter clear on Report send
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6ReportRateOfChange 1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.52
This variable configures a max. counter value within a time slot. If an input counter value exceeds this max. value, the corresponding Report is triggered. Input counters with its mask bit unset in wtWebCount6ReportInputTrigger are not considered. A value of Zero disable the tracing of rate of change.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6ReportRateOfChangeWindow 1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.53
This variable configures the time slot of wtWebCount6ReportRateOfChange. Input counters with its mask bit unset in wtWebCount6ReportInputTrigger are not considered. A value of Zero disable the tracing of rate of change.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6ReportRateOfChangeMode 1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.54
Binary coded options: Minimum mode: a report will be send if the count of pulses is lower than the given pulse count in wtWebCount6ReportRateOfChange. Maximum mode: a report will be send if the count of pulses is greater than the pulse count given in wtWebCount6ReportRateOfChange. The OCTETS are interpreted bit-by-bit, use only one bit at a time. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 2 : Maximum Mode Bit 1 : Minimum Mode Bit 0 : Rate of Change OFF
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6InputPortTable 1.3.6.1.4.1.5040.1.2.22.3.2.1
List of settings depending on the input number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebCount6InputPortEntry

wtWebCount6InputPortEntry 1.3.6.1.4.1.5040.1.2.22.3.2.1.1
Input parameter for the individual inputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebCount6InputPortEntry  

wtWebCount6PortInputName 1.3.6.1.4.1.5040.1.2.22.3.2.1.1.1
Name of the input.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6PortInputText 1.3.6.1.4.1.5040.1.2.22.3.2.1.1.2
Description of the input.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6PortInputMode 1.3.6.1.4.1.5040.1.2.22.3.2.1.1.3
Binary coded modes: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. Selection for input 0-1: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Bidirectional counter enable Bit 2 : unused Bit 1 : Change detection enable Bit 0 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebCount6PortInputFilter 1.3.6.1.4.1.5040.1.2.22.3.2.1.1.4
Pulses with a duration shorter than here specified (duration in 1/1000 sec), are ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebCount6PortInputPulsePolarity 1.3.6.1.4.1.5040.1.2.22.3.2.1.1.5
This value defines the polarity of the input pulse. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebCount6PortInputBicountInactivTimeout 1.3.6.1.4.1.5040.1.2.22.3.2.1.1.6
Pulse chains with a duration shorter than here specified (in 1/10 sek), are ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebCount6PortInputCounterSet 1.3.6.1.4.1.5040.1.2.22.3.2.1.1.7
Writing to this variable presets the counter, while reading returns the actual value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebCount6PortInputCounterScale 1.3.6.1.4.1.5040.1.2.22.3.2.1.1.8
Conversion factor for this counter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6PortInputCounterUnit 1.3.6.1.4.1.5040.1.2.22.3.2.1.1.9
Unit for this counter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6MfName 1.3.6.1.4.1.5040.1.2.22.3.3.1
Manufacturer company name
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6MfAddr 1.3.6.1.4.1.5040.1.2.22.3.3.2
Manufacturer address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6MfHotline 1.3.6.1.4.1.5040.1.2.22.3.3.3
Manufacturer hotline.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6MfInternet 1.3.6.1.4.1.5040.1.2.22.3.3.4
Manufacturer Internet address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6MfDeviceTyp 1.3.6.1.4.1.5040.1.2.22.3.3.5
Manufacturer device name (model number).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6MfOrderNo 1.3.6.1.4.1.5040.1.2.22.3.3.6
Manufacturer part number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6DiagErrorCount 1.3.6.1.4.1.5040.1.2.22.4.1
Number of entries in the error memory.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebCount6DiagBinaryError 1.3.6.1.4.1.5040.1.2.22.4.2
Error causes coded bit-by-bit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6DiagErrorIndex 1.3.6.1.4.1.5040.1.2.22.4.3
The value of this variable is used as an index to read an error massege from wtWebCount6DiagErrorMessage. Errors are numbered from 1 to wtWebCount6DiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebCount6DiagErrorMessage.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebCount6DiagErrorMessage 1.3.6.1.4.1.5040.1.2.22.4.4
Using wtWebCount6DiagErrorIndex as an index, the appropriate message is available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebCount6DiagErrorClear 1.3.6.1.4.1.5040.1.2.22.4.5
Writing 1 into this variable clears all diagnosis messages.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER  

wtWebCount6Alert1 41
This SNMP trap is generated when Report 1 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebCount6Alert2 42
This SNMP trap is generated when Report 2 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebCount6Alert3 43
This SNMP trap is generated when Report 3 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebCount6Alert4 44
This SNMP trap is generated when Report 4 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebCount6Alert5 45
This SNMP trap is generated when Report 5 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebCount6Alert6 46
This SNMP trap is generated when Report 6 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebCount6Alert7 47
This SNMP trap is generated when Report 7 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebCount6Alert8 48
This SNMP trap is generated when Report 8 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebCount6Alert9 49
This SNMP trap is generated when Report 9 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebCount6Alert10 50
This SNMP trap is generated when Report 10 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebCount6Alert11 51
This SNMP trap is generated when Report 11 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebCount6Alert12 52
This SNMP trap is generated when Report 12 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebCount6AlertDiag 110
This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA6x6Inputs 1.3.6.1.4.1.5040.1.2.24.1.1
Number of idependent inputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..6  

wtWebioEA6x6Outputs 1.3.6.1.4.1.5040.1.2.24.1.2
Number of idependent outputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..6  

wtWebioEA6x6InputTable 1.3.6.1.4.1.5040.1.2.24.1.3
List of input indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA6x6InputEntry

wtWebioEA6x6InputEntry 1.3.6.1.4.1.5040.1.2.24.1.3.1
Number of the inputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA6x6InputEntry  

wtWebioEA6x6InputNo 1.3.6.1.4.1.5040.1.2.24.1.3.1.1
Index numbers of the inputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebioEA6x6InputCounter 1.3.6.1.4.1.5040.1.2.24.1.3.1.2
Value of the input counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebioEA6x6InputCounterClear 1.3.6.1.4.1.5040.1.2.24.1.3.1.3
Clears the input counter after returning its value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA6x6InputState 1.3.6.1.4.1.5040.1.2.24.1.3.1.4
Value of a single input bit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtWebioEA6x6InputState-OFF(0), wtWebioEA6x6InputState-ON(1)  

wtWebioEA6x6InputValue 1.3.6.1.4.1.5040.1.2.24.1.4
This variable is used to read the inputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, unused OCTET 4, Bit 0-5: Digital outputs 0-5 Bit 6-7: unused
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA6x6OutputTable 1.3.6.1.4.1.5040.1.2.24.1.5
List of output indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA6x6OutputEntry

wtWebioEA6x6OutputEntry 1.3.6.1.4.1.5040.1.2.24.1.5.1
Number of the outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA6x6OutputEntry  

wtWebioEA6x6OutputNo 1.3.6.1.4.1.5040.1.2.24.1.5.1.1
Output number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebioEA6x6OutputState 1.3.6.1.4.1.5040.1.2.24.1.5.1.2
Value of a single output bit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA6x6OutputState-OFF(0), wtWebioEA6x6OutputState-ON(1)  

wtWebioEA6x6OutputValue 1.3.6.1.4.1.5040.1.2.24.1.6
This variable is used to read and write the outputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, unused OCTET 4, Bit 0-5: Digital outputs 0-5 Bit 6-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA6x6SetOutput 1.3.6.1.4.1.5040.1.2.24.1.7
This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first two OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4 : Bit 0-5: Mask for digital outputs 0-5 Bit 6-7: unused OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8 : Bit 0-5: Level of digital outputs 0-5 Bit 6-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

wtWebioEA6x6SessCntrlPassword 1.3.6.1.4.1.5040.1.2.24.2.1
Entering this password opens a session which is ended by writing a 1 to wtWebioEA6x6SessCntrlLogout. When read this variable provides a string of length zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6SessCntrlConfigMode 1.3.6.1.4.1.5040.1.2.24.2.2
When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtWebioEA6x6SessCntrl-NoSession(0), wtWebioEA6x6SessCntrl-Session(1)  

wtWebioEA6x6SessCntrlLogout 1.3.6.1.4.1.5040.1.2.24.2.3
If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA6x6SessCntrlAdminPassword 1.3.6.1.4.1.5040.1.2.24.2.4
This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6SessCntrlConfigPassword 1.3.6.1.4.1.5040.1.2.24.2.5
This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6DeviceName 1.3.6.1.4.1.5040.1.2.24.3.1.1.1
Name of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6DeviceText 1.3.6.1.4.1.5040.1.2.24.3.1.1.2
Description of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6DeviceLocation 1.3.6.1.4.1.5040.1.2.24.3.1.1.3
Description of the location of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6DeviceContact 1.3.6.1.4.1.5040.1.2.24.3.1.1.4
Contact address of the system operator of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6TzOffsetHrs 1.3.6.1.4.1.5040.1.2.24.3.1.2.1.1
Offset hours for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA6x6TzOffsetMin 1.3.6.1.4.1.5040.1.2.24.3.1.2.1.2
Offset minutes for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA6x6TzEnable 1.3.6.1.4.1.5040.1.2.24.3.1.2.1.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA6x6StTzOffsetHrs 1.3.6.1.4.1.5040.1.2.24.3.1.2.1.4
Offset hours of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA6x6StTzOffsetMin 1.3.6.1.4.1.5040.1.2.24.3.1.2.1.5
Offset minutes of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA6x6StTzEnable 1.3.6.1.4.1.5040.1.2.24.3.1.2.1.6
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA6x6StTzStartMonth 1.3.6.1.4.1.5040.1.2.24.3.1.2.1.7
Month in which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA6x6StartMonth-January(1), wtWebioEA6x6StartMonth-February(2), wtWebioEA6x6StartMonth-March(3), wtWebioEA6x6StartMonth-April(4), wtWebioEA6x6StartMonth-May(5), wtWebioEA6x6StartMonth-June(6), wtWebioEA6x6StartMonth-July(7), wtWebioEA6x6StartMonth-August(8), wtWebioEA6x6StartMonth-September(9), wtWebioEA6x6StartMonth-October(10), wtWebioEA6x6StartMonth-November(11), wtWebioEA6x6StartMonth-December(12)  

wtWebioEA6x6StTzStartMode 1.3.6.1.4.1.5040.1.2.24.3.1.2.1.8
Mode of the day of the week for which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA6x6StartMode-first(1), wtWebioEA6x6StartMode-second(2), wtWebioEA6x6StartMode-third(3), wtWebioEA6x6StartMode-fourth(4), wtWebioEA6x6StartMode-last(5)  

wtWebioEA6x6StTzStartWday 1.3.6.1.4.1.5040.1.2.24.3.1.2.1.9
Day of the week on which the change is made from winter time to summer time
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA6x6StartWday-Sunday(1), wtWebioEA6x6StartWday-Monday(2), wtWebioEA6x6StartWday-Tuesday(3), wtWebioEA6x6StartWday-Thursday(4), wtWebioEA6x6StartWday-Wednesday(5), wtWebioEA6x6StartWday-Friday(6), wtWebioEA6x6StartWday-Saturday(7)  

wtWebioEA6x6StTzStartHrs 1.3.6.1.4.1.5040.1.2.24.3.1.2.1.10
Hour in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA6x6StTzStartMin 1.3.6.1.4.1.5040.1.2.24.3.1.2.1.11
Minute in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA6x6StTzStopMonth 1.3.6.1.4.1.5040.1.2.24.3.1.2.1.12
Month in which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA6x6StopMonth-January(1), wtWebioEA6x6StopMonth-February(2), wtWebioEA6x6StopMonth-March(3), wtWebioEA6x6StopMonth-April(4), wtWebioEA6x6StopMonth-May(5), wtWebioEA6x6StopMonth-June(6), wtWebioEA6x6StopMonth-July(7), wtWebioEA6x6StopMonth-August(8), wtWebioEA6x6StopMonth-September(9), wtWebioEA6x6StopMonth-October(10), wtWebioEA6x6StopMonth-November(11), wtWebioEA6x6StopMonth-December(12)  

wtWebioEA6x6StTzStopMode 1.3.6.1.4.1.5040.1.2.24.3.1.2.1.13
Mode of the week day on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA6x6StopMode-first(1), wtWebioEA6x6StopMode-second(2), wtWebioEA6x6StopMode-third(3), wtWebioEA6x6StopMode-fourth(4), wtWebioEA6x6StopMode-last(5)  

wtWebioEA6x6StTzStopWday 1.3.6.1.4.1.5040.1.2.24.3.1.2.1.14
Day of the week on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA6x6StopWday-Sunday(1), wtWebioEA6x6StopWday-Monday(2), wtWebioEA6x6StopWday-Tuesday(3), wtWebioEA6x6StopWday-Thursday(4), wtWebioEA6x6StopWday-Wednesday(5), wtWebioEA6x6StopWday-Friday(6), wtWebioEA6x6StopWday-Saturday(7)  

wtWebioEA6x6StTzStopHrs 1.3.6.1.4.1.5040.1.2.24.3.1.2.1.15
Hour at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA6x6StTzStopMin 1.3.6.1.4.1.5040.1.2.24.3.1.2.1.16
Minute at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA6x6TimeServer1 1.3.6.1.4.1.5040.1.2.24.3.1.2.2.1
IP address or name of the 1st time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6TimeServer2 1.3.6.1.4.1.5040.1.2.24.3.1.2.2.2
IP address or name of the 2nd time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6TsEnable 1.3.6.1.4.1.5040.1.2.24.3.1.2.2.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA6x6TsSyncTime 1.3.6.1.4.1.5040.1.2.24.3.1.2.2.4
Daily synchronisation time with the time server (hour: 0-23).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA6x6ClockHrs 1.3.6.1.4.1.5040.1.2.24.3.1.2.3.1
Clock hours taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..23  

wtWebioEA6x6ClockMin 1.3.6.1.4.1.5040.1.2.24.3.1.2.3.2
Clock minutes taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..59  

wtWebioEA6x6ClockDay 1.3.6.1.4.1.5040.1.2.24.3.1.2.3.3
Date: Day of the month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..31  

wtWebioEA6x6ClockMonth 1.3.6.1.4.1.5040.1.2.24.3.1.2.3.4
Date: Month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA6x6ClockMonth-January(1), wtWebioEA6x6ClockMonth-February(2), wtWebioEA6x6ClockMonth-March(3), wtWebioEA6x6ClockMonth-April(4), wtWebioEA6x6ClockMonth-May(5), wtWebioEA6x6ClockMonth-June(6), wtWebioEA6x6ClockMonth-July(7), wtWebioEA6x6ClockMonth-August(8), wtWebioEA6x6ClockMonth-September(9), wtWebioEA6x6ClockMonth-October(10), wtWebioEA6x6ClockMonth-November(11), wtWebioEA6x6ClockMonth-December(12)  

wtWebioEA6x6ClockYear 1.3.6.1.4.1.5040.1.2.24.3.1.2.3.5
Date: Year, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA6x6IpAddress 1.3.6.1.4.1.5040.1.2.24.3.1.3.1.1
IP address of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioEA6x6SubnetMask 1.3.6.1.4.1.5040.1.2.24.3.1.3.1.2
Subnet mask of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioEA6x6Gateway 1.3.6.1.4.1.5040.1.2.24.3.1.3.1.3
Gateway of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioEA6x6DnsServer1 1.3.6.1.4.1.5040.1.2.24.3.1.3.1.4
IP address of the 1st DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6DnsServer2 1.3.6.1.4.1.5040.1.2.24.3.1.3.1.5
IP address of the 2nd DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6AddConfig 1.3.6.1.4.1.5040.1.2.24.3.1.3.1.6
Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP enable Bit 0: BOOTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6Startup 1.3.6.1.4.1.5040.1.2.24.3.1.3.2.1
Binary coded start page, more than one page must not be selected: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2: user.htm Bit 1: home.htm Bit 0: index.htm
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6GetHeaderEnable 1.3.6.1.4.1.5040.1.2.24.3.1.3.2.2
If bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device (Header) or a HTTP header (HTTP): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2-7: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6HttpInputTrigger 1.3.6.1.4.1.5040.1.2.24.3.1.3.2.3
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-5: Digital inputs 0-5 Bit 6-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA6x6HttpPort 1.3.6.1.4.1.5040.1.2.24.3.1.3.2.4
Definition of the standard HTML port (Default: 80).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65534  

wtWebioEA6x6MailAdName 1.3.6.1.4.1.5040.1.2.24.3.1.3.3.1
Device name for mail administration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6MailReply 1.3.6.1.4.1.5040.1.2.24.3.1.3.3.2
Reply address for the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6MailServer 1.3.6.1.4.1.5040.1.2.24.3.1.3.3.3
Name or IP address of the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6MailEnable 1.3.6.1.4.1.5040.1.2.24.3.1.3.3.4
Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6MailAuthentication 1.3.6.1.4.1.5040.1.2.24.3.1.3.3.5
Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA6x6MailAuthUser 1.3.6.1.4.1.5040.1.2.24.3.1.3.3.6
Name of the user to be authenticated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6MailAuthPassword 1.3.6.1.4.1.5040.1.2.24.3.1.3.3.7
Authentication password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6MailPop3Server 1.3.6.1.4.1.5040.1.2.24.3.1.3.3.8
Name or Ip-address of the POP3 Servers.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6SnmpEnable 1.3.6.1.4.1.5040.1.2.24.3.1.3.4.1
Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6SnmpCommunityStringRead 1.3.6.1.4.1.5040.1.2.24.3.1.3.4.2
Community string read only
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6SnmpCommunityStringReadWrite 1.3.6.1.4.1.5040.1.2.24.3.1.3.4.3
Community string read / write
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6SnmpSystemTrapManagerIP 1.3.6.1.4.1.5040.1.2.24.3.1.3.4.4
Name or IP address of the TCP server which accepts the system trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6SnmpSystemTrapEnable 1.3.6.1.4.1.5040.1.2.24.3.1.3.4.5
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag messages Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA6x6UdpAdminPort 1.3.6.1.4.1.5040.1.2.24.3.1.3.5.1
Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA6x6UdpEnable 1.3.6.1.4.1.5040.1.2.24.3.1.3.5.2
Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6UdpRemotePort 1.3.6.1.4.1.5040.1.2.24.3.1.3.5.3
Udp remote port setting. If this value is set to zero, the source port read from a request will be used as destination port for the answer. A non zero value forced the destination port to this value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA6x6BinaryModeCount 1.3.6.1.4.1.5040.1.2.24.3.1.3.6.1
Number of independent binary channels.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtWebioEA6x6BinaryIfTable 1.3.6.1.4.1.5040.1.2.24.3.1.3.6.2
Table of indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA6x6BinaryIfEntry

wtWebioEA6x6BinaryIfEntry 1.3.6.1.4.1.5040.1.2.24.3.1.3.6.2.1
Indices of the binary channels.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA6x6BinaryIfEntry  

wtWebioEA6x6BinaryModeNo 1.3.6.1.4.1.5040.1.2.24.3.1.3.6.2.1.1
Number of the binary channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtWebioEA6x6BinaryTable 1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3
Table of properties of the binary mode.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA6x6BinaryEntry

wtWebioEA6x6BinaryEntry 1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1
Binary properties.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA6x6BinaryEntry  

wtWebioEA6x6BinaryOperationMode 1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.1
Selection of the operation mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : UDP Peer Bit 1 : TCP Client Bit 0 : TCP Server
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA6x6BinaryTcpServerLocalPort 1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.2
Local TCP port for data exchange in this server mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA6x6BinaryTcpServerInputTrigger 1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.3
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-5: Digital inputs 0-5 Bit 6-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA6x6BinaryTcpServerApplicationMode 1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.4
Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 4-7: unused Bit 3 : OPC Device Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA6x6BinaryTcpClientLocalPort 1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.5
Local TCP port for data exchange in this client mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA6x6BinaryTcpClientServerPort 1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.6
Port number of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server port to zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA6x6BinaryTcpClientServerIpAddr 1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.7
Ip address of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server IP address to 0.0.0.0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6BinaryTcpClientServerPassword 1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.8
Building a connection may be protected by the administrator password of the server. Enter the server password to establish the connection, if a server administrator password exists.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6BinaryTcpClientInactivity 1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.9
Connection timeout in 100ms. If no data are exchanged within the specified time, the device closes the connection to the server. The value 0 deactivates the timer. Using the Box2Box mode this function is disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA6x6BinaryTcpClientInputTrigger 1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.10
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-5: Digital inputs 0-5 Bit 6-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA6x6BinaryTcpClientInterval 1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.11
Configurable interval with a 100ms base, in which the Webio device sends data to the configured application. A interval of zero stopps the periodical sending.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA6x6BinaryTcpClientApplicationMode 1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.12
Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA6x6BinaryUdpPeerLocalPort 1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.13
Local UDP port for data exchange in this peer to peer mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA6x6BinaryUdpPeerRemotePort 1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.14
Port number of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote port to zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA6x6BinaryUdpPeerRemoteIpAddr 1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.15
Ip address of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote device IP address to 0.0.0.0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6BinaryUdpPeerInputTrigger 1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.16
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-5: Digital inputs 0-5 Bit 6-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA6x6BinaryUdpPeerInterval 1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.17
Configurable interval with a 100ms base, in which the Webio device sends data to the configured remote device. A interval of zero stopps the periodical sending.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA6x6BinaryUdpPeerApplicationMode 1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.18
Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA6x6BinaryConnectedPort 1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.19
Port number of the remote device, after connection has been established. In case of no connection or missing port informations a zero will be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA6x6BinaryConnectedIpAddr 1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.20
IP address of the remote device, after connection has been established. In case of no connection or missing port informations 0.0.0.0 will be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

wtWebioEA6x6BinaryTcpServerClientHttpPort 1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.21
HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs status informations will be send to this port. Not used at mode Compatible 50xxx.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA6x6BinaryTcpClientServerHttpPort 1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.22
HTTP port number of the remote device at TCP Client Mode. In the operating mode Box2Box connection status informations will be exchanged through this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA6x6SyslogServerIP 1.3.6.1.4.1.5040.1.2.24.3.1.3.7.1
Name or IP address of the Syslog server, which accepts the Syslog messgaes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6SyslogServerPort 1.3.6.1.4.1.5040.1.2.24.3.1.3.7.2
Portnumber of the Syslog servers, default 514.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA6x6SyslogSystemMessagesEnable 1.3.6.1.4.1.5040.1.2.24.3.1.3.7.3
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA6x6SyslogEnable 1.3.6.1.4.1.5040.1.2.24.3.1.3.7.4
Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6FTPServerIP 1.3.6.1.4.1.5040.1.2.24.3.1.3.8.1
Name or IP address of the FTP server, which accepts the FTP messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6FTPServerControlPort 1.3.6.1.4.1.5040.1.2.24.3.1.3.8.2
Portnumber of the control port of the FTP server, default 21.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA6x6FTPUserName 1.3.6.1.4.1.5040.1.2.24.3.1.3.8.3
FTP Loggin: user name.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6FTPPassword 1.3.6.1.4.1.5040.1.2.24.3.1.3.8.4
FTP Loggin: user password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6FTPAccount 1.3.6.1.4.1.5040.1.2.24.3.1.3.8.5
FTP Loggin: name of account.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6FTPOption 1.3.6.1.4.1.5040.1.2.24.3.1.3.8.6
Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6FTPEnable 1.3.6.1.4.1.5040.1.2.24.3.1.3.8.7
Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6OutputModeTable 1.3.6.1.4.1.5040.1.2.24.3.1.4.1
Table of output mode configurations dependent on the output indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA6x6OutputModeEntry

wtWebioEA6x6OutputModeEntry 1.3.6.1.4.1.5040.1.2.24.3.1.4.1.1
Output mode configurations of the individual outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA6x6OutputModeEntry  

wtWebioEA6x6OutputModeBit 1.3.6.1.4.1.5040.1.2.24.3.1.4.1.1.1
This binary coded output mode defines the individual operation mode for any output. More than one mode must not be selected. The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 6-7: unused Bit 5 : Logic Bit 4 : Binary 2 Bit 3 : Binary 1 Bit 2 : SNMP Bit 1 : UDP ASCII Bit 0 : HTTP
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA6x6SafetyTimeout 1.3.6.1.4.1.5040.1.2.24.3.1.4.2
After this period of time (multiple of 100ms) without receiving data outputs switch to their Safety States. For each output a independend safety state could be defined.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA6x6AlarmCount 1.3.6.1.4.1.5040.1.2.24.3.1.5.1
Number of independent alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..12  

wtWebioEA6x6AlarmIfTable 1.3.6.1.4.1.5040.1.2.24.3.1.5.2
List of alarm indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA6x6AlarmIfEntry

wtWebioEA6x6AlarmIfEntry 1.3.6.1.4.1.5040.1.2.24.3.1.5.2.1
Numbers of the alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA6x6AlarmIfEntry  

wtWebioEA6x6AlarmNo 1.3.6.1.4.1.5040.1.2.24.3.1.5.2.1.1
Numbers of the alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..12  

wtWebioEA6x6AlarmTable 1.3.6.1.4.1.5040.1.2.24.3.1.5.3
List of settings depending on the alarm number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA6x6AlarmEntry

wtWebioEA6x6AlarmEntry 1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1
Alarm parameters of the individual alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA6x6AlarmEntry  

wtWebioEA6x6AlarmInputTrigger 1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.1
This variable allows setting of individual input trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the inputs are to be considered (corresponding bit = 1) and which inputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-5: Mask for digital inputs 0-5 Bit 6-7: unused OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-5: Level of digital inputs 0-5 Bit 6-7: unused OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change of the corresponding input bit. Settings in OCTET 5-9 are then unused: OCTET 9 : unused OCTET 10: unused OCTET 11: unused OCTET 12, Bit 0-5: ANY bits of digital inputs 0-5 Bit 6-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(12)  

wtWebioEA6x6AlarmOutputTrigger 1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.2
This variable allows setting of individual output trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be considered (corresponding bit = 1) and which outputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-5: Mask for digital outputs 0-5 Bit 6-7: unused OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-5: Level of digital outputs 0-5 Bit 6-7: unused OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change of the corresponding output bit. Settings in OCTET 5-9 are then unused: OCTET 9 : unused OCTET 10: unused OCTET 11: unused OCTET 12, Bit 0-5: ANY bits of digital outputs 0-5 Bit 6-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(12)  

wtWebioEA6x6AlarmSystemTrigger 1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.3
Binary coded trigger conditions: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Warm Start Bit 2 : Cold Start Bit 1 : Timer Bit 0 : Load Control
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA6x6AlarmMaxCounterValue 1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.4
This variable configures a max. counter value. If an input counter value exceeds this max. value, the corresponding alarm is triggered. Input counters with its mask bit unset in wtWebioEA6x6AlarmInputTrigger are not considered.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6AlarmInterval 1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.5
Send interval for alarm messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6AlarmEnable 1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.6
Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: UDP enable Bit 3: Send inputs to pending TCP connections Bit 4: TCP Client enable Bit 5: Syslog Messages enable Bit 6-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA6x6AlarmMailAddr 1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.7
E-Mail address for sending the alarm mail to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6AlarmMailSubject 1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.8
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6AlarmMailText 1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.9
Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6AlarmSnmpManagerIP 1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.10
IP address of the SNMP Manager to which the Webio device should send SNMP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6AlarmSnmpTrapText 1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.11
This text appears in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6AlarmUdpIpAddr 1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.12
IP address of the UDP listener to which the Webio device should send UDP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6AlarmUdpPort 1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.13
Port number of the UDP listener to which the Webio device should send UDP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA6x6AlarmUdpText 1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.14
This text appears in the UDP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6AlarmTcpIpAddr 1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.15
IP address of the TCP listener to which the Webio device should send TCP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6AlarmTcpPort 1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.16
Port number of the TCP listener to which the Webio device should send TCP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA6x6AlarmTcpText 1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.17
This text appears in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6AlarmSyslogIpAddr 1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.18
IP address of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6AlarmSyslogPort 1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.19
Port number of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA6x6AlarmSyslogText 1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.20
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6AlarmFtpDataPort 1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.21
Local data port: 1..65535 or AUTO: the next free port will be assigned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6AlarmFtpFileName 1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.22
Name of the file including path informations.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6AlarmFtpText 1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.23
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6AlarmFtpOption 1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.24
Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA6x6AlarmTimerCron 1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.25
This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6AlarmMailReleaseSubject 1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.26
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6AlarmMailReleaseText 1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.27
Release Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6AlarmSnmpTrapReleaseText 1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.28
This text appears in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6AlarmUdpReleaseText 1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.29
This text appears in the UDP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6AlarmTcpReleaseText 1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.30
This text appears in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6AlarmSyslogReleaseText 1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.31
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6AlarmFtpReleaseText 1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.32
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6InputPortTable 1.3.6.1.4.1.5040.1.2.24.3.2.1
List of settings depending on the input number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA6x6InputPortEntry

wtWebioEA6x6InputPortEntry 1.3.6.1.4.1.5040.1.2.24.3.2.1.1
Input parameter for the individual inputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA6x6InputPortEntry  

wtWebioEA6x6PortInputName 1.3.6.1.4.1.5040.1.2.24.3.2.1.1.1
Name of the input.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6PortInputText 1.3.6.1.4.1.5040.1.2.24.3.2.1.1.2
Description of the input.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6PortInputMode 1.3.6.1.4.1.5040.1.2.24.3.2.1.1.3
Binary coded modes: Selecting short pulse detection enable by setting the corresponding bit to 1 enables interrupt support for counting. Only positive edges are accepted as trigger source. The maximum counting frequenz equals 2000 Hz. This mode is available for inputs 0-3 only. Selecting counter clear on read by setting the corresponding bit to 1 enables the corresponding counter to be cleared automatically every time it is read, except HTTP reading with user rights. The OCTETS are interpreted bit-by-bit, with each set of octets corresponding to an input. Bit 0 corresponds to the LSB. Selection for input 0-3: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 3-7: unused Bit 2 : Counter clear on read Bit 1 : Change detection enable (default) Bit 0 : Short Pulse detection enable Selection for inputs 4-5: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : Counter clear on read Bit 0 : Change detection enable (default)
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA6x6PortInputFilter 1.3.6.1.4.1.5040.1.2.24.3.2.1.1.4
Pulses with a duration shorter than here specified (duration in 1/1000 sec), are ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA6x6PortInputBicountPulsePolarity 1.3.6.1.4.1.5040.1.2.24.3.2.1.1.5
This value defines the polarity of the input pulse. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA6x6PortInputBicountInactivTimeout 1.3.6.1.4.1.5040.1.2.24.3.2.1.1.6
Pulse chains with a duration shorter than here specified (in 1/10 sek), are ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA6x6OutputPortTable 1.3.6.1.4.1.5040.1.2.24.3.2.2
List of settings depending on the output number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA6x6OutputPortEntry

wtWebioEA6x6OutputPortEntry 1.3.6.1.4.1.5040.1.2.24.3.2.2.1
Output parameters of the individual outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA6x6OutputPortEntry  

wtWebioEA6x6PortOutputName 1.3.6.1.4.1.5040.1.2.24.3.2.2.1.1
Name of the output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6PortOutputText 1.3.6.1.4.1.5040.1.2.24.3.2.2.1.2
Description of the output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6PortOutputGroupMode 1.3.6.1.4.1.5040.1.2.24.3.2.2.1.3
It is possible to connect outputs together to increase the output current. This could be done by connecting 2 or 4 outputs in a group together. All bits of such a group has to be set all together in the same way. This variable configures this group scheme. If one output bit of a group is set, all other output bits of the same group will be set in the same manner. More than one configuration must not be selected. Selection for outputs 0-3: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: Bit 0 : outputs 0,1,2,3 disconnected (default) Bit 1 : outputs 0+1, 2+3 connected Bit 2 : outputs 0+1+2+3 connected Bit 3-7 : unused Selection for outputs 4-7: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: Bit 0 : outputs 4, 5 disconnected (default) Bit 1 : outputs 4+5 connected Bit 2-7 : unused Selection for outputs 8-11: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6PortOutputSafetyState 1.3.6.1.4.1.5040.1.2.24.3.2.2.1.4
This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 1-7: unused Bit 0 : Mask for digital output OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs to be changed should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 1-7: unused Bit 0 : Level of digital output
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6PortLogicInputMask 1.3.6.1.4.1.5040.1.2.24.3.2.2.1.5
Selecting one of these inputs by setting the corresponding bit to 1 enables the logic function for the output identified by the index within this table. The calculation take place in 4 steps: 1. Selecting inputs (wtWebioEA6x6PortLogicInputMask) 2. Inverting inputs if necessary (wtWebioEA6x6PortLogicInputInverter) 3. Logical combination (wtWebioEA6x6PortLogicFunction) 4. Inverting the result if necessary (wtWebioEA6x6PortLogicOutputInverter) OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0-5 : inputs 0-5 Bit 6-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA6x6PortLogicInputInverter 1.3.6.1.4.1.5040.1.2.24.3.2.2.1.6
Every input bit selected here will be inverted. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0-5 : inputs 0-5 Bit 6-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA6x6PortLogicFunction 1.3.6.1.4.1.5040.1.2.24.3.2.2.1.7
This determines the logic function. No more than one function may be selected. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : logic function OR (default) Bit 1 : logic function AND Bit 2-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA6x6PortLogicOutputInverter 1.3.6.1.4.1.5040.1.2.24.3.2.2.1.8
The logical operation result could be inverteted by setting the corresponding bit to 1. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : Output Inverter enable Bit 1-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA6x6PortPulseDuration 1.3.6.1.4.1.5040.1.2.24.3.2.2.1.9
Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA6x6PortPulsePolarity 1.3.6.1.4.1.5040.1.2.24.3.2.2.1.10
This value defines the polarity of the output pulse, if wtWebioEA6x6PortPulseDuration is not set to zero. After the pulse is finished, the output switches back to the opposite state. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA6x6MfName 1.3.6.1.4.1.5040.1.2.24.3.3.1
Manufacturer company name
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6MfAddr 1.3.6.1.4.1.5040.1.2.24.3.3.2
Manufacturer address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6MfHotline 1.3.6.1.4.1.5040.1.2.24.3.3.3
Manufacturer hotline.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6MfInternet 1.3.6.1.4.1.5040.1.2.24.3.3.4
Manufacturer Internet address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6MfDeviceTyp 1.3.6.1.4.1.5040.1.2.24.3.3.5
Manufacturer device name (model number).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6DiagErrorCount 1.3.6.1.4.1.5040.1.2.24.4.1
Number of entries in the error memory.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA6x6DiagBinaryError 1.3.6.1.4.1.5040.1.2.24.4.2
Error causes coded bit-by-bit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6DiagErrorIndex 1.3.6.1.4.1.5040.1.2.24.4.3
The value of this variable is used as an index to read an error massege from wtWebioEA6x6DiagErrorMessage. Errors are numbered from 1 to wtWebioEA6x6DiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebioEA6x6DiagErrorMessage.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA6x6DiagErrorMessage 1.3.6.1.4.1.5040.1.2.24.4.4
Using wtWebioEA6x6DiagErrorIndex as an index, the appropriate message is available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA6x6DiagErrorClear 1.3.6.1.4.1.5040.1.2.24.4.5
Writing 1 into this variable clears all diagnosis messages.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA6x6Alert1 41
This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA6x6Alert2 42
This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA6x6Alert3 43
This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA6x6Alert4 44
This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA6x6Alert5 45
This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA6x6Alert6 46
This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA6x6Alert7 47
This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA6x6Alert8 48
This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA6x6Alert9 49
This SNMP trap is generated when Alarm 9 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA6x6Alert10 50
This SNMP trap is generated when Alarm 10 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA6x6Alert11 51
This SNMP trap is generated when Alarm 11 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA6x6Alert12 52
This SNMP trap is generated when Alarm 12 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA6x6Alert13 71
This SNMP trap is generated when Alarm 1 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA6x6Alert14 72
This SNMP trap is generated when Alarm 2 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA6x6Alert15 73
This SNMP trap is generated when Alarm 3 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA6x6Alert16 74
This SNMP trap is generated when Alarm 4 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA6x6Alert17 75
This SNMP trap is generated when Alarm 5 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA6x6Alert18 76
This SNMP trap is generated when Alarm 6 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA6x6Alert19 77
This SNMP trap is generated when Alarm 7 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA6x6Alert20 78
This SNMP trap is generated when Alarm 8 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA6x6Alert21 79
This SNMP trap is generated when Alarm 9 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA6x6Alert22 80
This SNMP trap is generated when Alarm 10 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA6x6Alert23 81
This SNMP trap is generated when Alarm 11 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA6x6Alert24 82
This SNMP trap is generated when Alarm 12 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA6x6AlertDiag 110
This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERPInputs 1.3.6.1.4.1.5040.1.2.25.1.1
Number of idependent inputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtWebioEA2x2ERPOutputs 1.3.6.1.4.1.5040.1.2.25.1.2
Number of idependent outputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtWebioEA2x2ERPInputTable 1.3.6.1.4.1.5040.1.2.25.1.3
List of input indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2ERPInputEntry

wtWebioEA2x2ERPInputEntry 1.3.6.1.4.1.5040.1.2.25.1.3.1
Number of the inputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2ERPInputEntry  

wtWebioEA2x2ERPInputNo 1.3.6.1.4.1.5040.1.2.25.1.3.1.1
Index numbers of the inputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebioEA2x2ERPInputCounter 1.3.6.1.4.1.5040.1.2.25.1.3.1.2
Value of the input counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebioEA2x2ERPInputCounterClear 1.3.6.1.4.1.5040.1.2.25.1.3.1.3
Clears the input counter after returning its value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERPInputState 1.3.6.1.4.1.5040.1.2.25.1.3.1.4
Value of a single input bit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtWebioEA2x2ERPInputState-OFF(0), wtWebioEA2x2ERPInputState-ON(1)  

wtWebioEA2x2ERPInputValue 1.3.6.1.4.1.5040.1.2.25.1.4
This variable is used to read the inputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital outputs 0-1
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERPOutputTable 1.3.6.1.4.1.5040.1.2.25.1.5
List of output indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2ERPOutputEntry

wtWebioEA2x2ERPOutputEntry 1.3.6.1.4.1.5040.1.2.25.1.5.1
Number of the outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2ERPOutputEntry  

wtWebioEA2x2ERPOutputNo 1.3.6.1.4.1.5040.1.2.25.1.5.1.1
Output number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebioEA2x2ERPOutputState 1.3.6.1.4.1.5040.1.2.25.1.5.1.2
Value of a single output bit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA2x2ERPOutputState-OFF(0), wtWebioEA2x2ERPOutputState-ON(1)  

wtWebioEA2x2ERPOutputValue 1.3.6.1.4.1.5040.1.2.25.1.6
This variable is used to read and write the outputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital outputs 0-1 Bit 2-7: ungenutzt
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERPSetOutput 1.3.6.1.4.1.5040.1.2.25.1.7
This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first two OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital outputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital outputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

wtWebioEA2x2ERPSessCntrlPassword 1.3.6.1.4.1.5040.1.2.25.2.1
Entering this password opens a session which is ended by writing a 1 to wtWebioEA2x2ERPSessCntrlLogout. When read this variable provides a string of length zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPSessCntrlConfigMode 1.3.6.1.4.1.5040.1.2.25.2.2
When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtWebioEA2x2ERPSessCntrl-NoSession(0), wtWebioEA2x2ERPSessCntrl-Session(1)  

wtWebioEA2x2ERPSessCntrlLogout 1.3.6.1.4.1.5040.1.2.25.2.3
If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERPSessCntrlAdminPassword 1.3.6.1.4.1.5040.1.2.25.2.4
This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPSessCntrlConfigPassword 1.3.6.1.4.1.5040.1.2.25.2.5
This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPDeviceName 1.3.6.1.4.1.5040.1.2.25.3.1.1.1
Name of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPDeviceText 1.3.6.1.4.1.5040.1.2.25.3.1.1.2
Description of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPDeviceLocation 1.3.6.1.4.1.5040.1.2.25.3.1.1.3
Description of the location of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPDeviceContact 1.3.6.1.4.1.5040.1.2.25.3.1.1.4
Contact address of the system operator of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPTzOffsetHrs 1.3.6.1.4.1.5040.1.2.25.3.1.2.1.1
Offset hours for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERPTzOffsetMin 1.3.6.1.4.1.5040.1.2.25.3.1.2.1.2
Offset minutes for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERPTzEnable 1.3.6.1.4.1.5040.1.2.25.3.1.2.1.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERPStTzOffsetHrs 1.3.6.1.4.1.5040.1.2.25.3.1.2.1.4
Offset hours of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERPStTzOffsetMin 1.3.6.1.4.1.5040.1.2.25.3.1.2.1.5
Offset minutes of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERPStTzEnable 1.3.6.1.4.1.5040.1.2.25.3.1.2.1.6
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERPStTzStartMonth 1.3.6.1.4.1.5040.1.2.25.3.1.2.1.7
Month in which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA2x2ERPStartMonth-January(1), wtWebioEA2x2ERPStartMonth-February(2), wtWebioEA2x2ERPStartMonth-March(3), wtWebioEA2x2ERPStartMonth-April(4), wtWebioEA2x2ERPStartMonth-May(5), wtWebioEA2x2ERPStartMonth-June(6), wtWebioEA2x2ERPStartMonth-July(7), wtWebioEA2x2ERPStartMonth-August(8), wtWebioEA2x2ERPStartMonth-September(9), wtWebioEA2x2ERPStartMonth-October(10), wtWebioEA2x2ERPStartMonth-November(11), wtWebioEA2x2ERPStartMonth-December(12)  

wtWebioEA2x2ERPStTzStartMode 1.3.6.1.4.1.5040.1.2.25.3.1.2.1.8
Mode of the day of the week for which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA2x2ERPStartMode-first(1), wtWebioEA2x2ERPStartMode-second(2), wtWebioEA2x2ERPStartMode-third(3), wtWebioEA2x2ERPStartMode-fourth(4), wtWebioEA2x2ERPStartMode-last(5)  

wtWebioEA2x2ERPStTzStartWday 1.3.6.1.4.1.5040.1.2.25.3.1.2.1.9
Day of the week on which the change is made from winter time to summer time
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA2x2ERPStartWday-Sunday(1), wtWebioEA2x2ERPStartWday-Monday(2), wtWebioEA2x2ERPStartWday-Tuesday(3), wtWebioEA2x2ERPStartWday-Thursday(4), wtWebioEA2x2ERPStartWday-Wednesday(5), wtWebioEA2x2ERPStartWday-Friday(6), wtWebioEA2x2ERPStartWday-Saturday(7)  

wtWebioEA2x2ERPStTzStartHrs 1.3.6.1.4.1.5040.1.2.25.3.1.2.1.10
Hour in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERPStTzStartMin 1.3.6.1.4.1.5040.1.2.25.3.1.2.1.11
Minute in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERPStTzStopMonth 1.3.6.1.4.1.5040.1.2.25.3.1.2.1.12
Month in which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA2x2ERPStopMonth-January(1), wtWebioEA2x2ERPStopMonth-February(2), wtWebioEA2x2ERPStopMonth-March(3), wtWebioEA2x2ERPStopMonth-April(4), wtWebioEA2x2ERPStopMonth-May(5), wtWebioEA2x2ERPStopMonth-June(6), wtWebioEA2x2ERPStopMonth-July(7), wtWebioEA2x2ERPStopMonth-August(8), wtWebioEA2x2ERPStopMonth-September(9), wtWebioEA2x2ERPStopMonth-October(10), wtWebioEA2x2ERPStopMonth-November(11), wtWebioEA2x2ERPStopMonth-December(12)  

wtWebioEA2x2ERPStTzStopMode 1.3.6.1.4.1.5040.1.2.25.3.1.2.1.13
Mode of the week day on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA2x2ERPStopMode-first(1), wtWebioEA2x2ERPStopMode-second(2), wtWebioEA2x2ERPStopMode-third(3), wtWebioEA2x2ERPStopMode-fourth(4), wtWebioEA2x2ERPStopMode-last(5)  

wtWebioEA2x2ERPStTzStopWday 1.3.6.1.4.1.5040.1.2.25.3.1.2.1.14
Day of the week on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA2x2ERPStopWday-Sunday(1), wtWebioEA2x2ERPStopWday-Monday(2), wtWebioEA2x2ERPStopWday-Tuesday(3), wtWebioEA2x2ERPStopWday-Thursday(4), wtWebioEA2x2ERPStopWday-Wednesday(5), wtWebioEA2x2ERPStopWday-Friday(6), wtWebioEA2x2ERPStopWday-Saturday(7)  

wtWebioEA2x2ERPStTzStopHrs 1.3.6.1.4.1.5040.1.2.25.3.1.2.1.15
Hour at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERPStTzStopMin 1.3.6.1.4.1.5040.1.2.25.3.1.2.1.16
Minute at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERPTimeServer1 1.3.6.1.4.1.5040.1.2.25.3.1.2.2.1
IP address or name of the 1st time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPTimeServer2 1.3.6.1.4.1.5040.1.2.25.3.1.2.2.2
IP address or name of the 2nd time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPTsEnable 1.3.6.1.4.1.5040.1.2.25.3.1.2.2.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERPTsSyncTime 1.3.6.1.4.1.5040.1.2.25.3.1.2.2.4
Daily synchronisation time with the time server (hour: 0-23).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERPClockHrs 1.3.6.1.4.1.5040.1.2.25.3.1.2.3.1
Clock hours taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..23  

wtWebioEA2x2ERPClockMin 1.3.6.1.4.1.5040.1.2.25.3.1.2.3.2
Clock minutes taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..59  

wtWebioEA2x2ERPClockDay 1.3.6.1.4.1.5040.1.2.25.3.1.2.3.3
Date: Day of the month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..31  

wtWebioEA2x2ERPClockMonth 1.3.6.1.4.1.5040.1.2.25.3.1.2.3.4
Date: Month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA2x2ERPClockMonth-January(1), wtWebioEA2x2ERPClockMonth-February(2), wtWebioEA2x2ERPClockMonth-March(3), wtWebioEA2x2ERPClockMonth-April(4), wtWebioEA2x2ERPClockMonth-May(5), wtWebioEA2x2ERPClockMonth-June(6), wtWebioEA2x2ERPClockMonth-July(7), wtWebioEA2x2ERPClockMonth-August(8), wtWebioEA2x2ERPClockMonth-September(9), wtWebioEA2x2ERPClockMonth-October(10), wtWebioEA2x2ERPClockMonth-November(11), wtWebioEA2x2ERPClockMonth-December(12)  

wtWebioEA2x2ERPClockYear 1.3.6.1.4.1.5040.1.2.25.3.1.2.3.5
Date: Year, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA2x2ERPIpAddress 1.3.6.1.4.1.5040.1.2.25.3.1.3.1.1
IP address of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioEA2x2ERPSubnetMask 1.3.6.1.4.1.5040.1.2.25.3.1.3.1.2
Subnet mask of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioEA2x2ERPGateway 1.3.6.1.4.1.5040.1.2.25.3.1.3.1.3
Gateway of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioEA2x2ERPDnsServer1 1.3.6.1.4.1.5040.1.2.25.3.1.3.1.4
IP address of the 1st DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPDnsServer2 1.3.6.1.4.1.5040.1.2.25.3.1.3.1.5
IP address of the 2nd DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPAddConfig 1.3.6.1.4.1.5040.1.2.25.3.1.3.1.6
Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP enable Bit 0: BOOTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPStartup 1.3.6.1.4.1.5040.1.2.25.3.1.3.2.1
Binary coded start page, more than one page must not be selected: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2: user.htm Bit 1: home.htm Bit 0: index.htm
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPGetHeaderEnable 1.3.6.1.4.1.5040.1.2.25.3.1.3.2.2
If bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device (Header) or a HTTP header (HTTP): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2-7: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPHttpInputTrigger 1.3.6.1.4.1.5040.1.2.25.3.1.3.2.3
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERPHttpPort 1.3.6.1.4.1.5040.1.2.25.3.1.3.2.4
Definition of the standard HTML port (Default: 80).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65534  

wtWebioEA2x2ERPMailAdName 1.3.6.1.4.1.5040.1.2.25.3.1.3.3.1
Device name for mail administration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPMailReply 1.3.6.1.4.1.5040.1.2.25.3.1.3.3.2
Reply address for the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPMailServer 1.3.6.1.4.1.5040.1.2.25.3.1.3.3.3
Name or IP address of the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPMailEnable 1.3.6.1.4.1.5040.1.2.25.3.1.3.3.4
Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPMailAuthentication 1.3.6.1.4.1.5040.1.2.25.3.1.3.3.5
Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERPMailAuthUser 1.3.6.1.4.1.5040.1.2.25.3.1.3.3.6
Name of the user to be authenticated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPMailAuthPassword 1.3.6.1.4.1.5040.1.2.25.3.1.3.3.7
Authentication password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPMailPop3Server 1.3.6.1.4.1.5040.1.2.25.3.1.3.3.8
Name or Ip-address of the POP3 Servers.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPSnmpEnable 1.3.6.1.4.1.5040.1.2.25.3.1.3.4.1
Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPSnmpCommunityStringRead 1.3.6.1.4.1.5040.1.2.25.3.1.3.4.2
Community string read only
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPSnmpCommunityStringReadWrite 1.3.6.1.4.1.5040.1.2.25.3.1.3.4.3
Community string read / write
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPSnmpSystemTrapManagerIP 1.3.6.1.4.1.5040.1.2.25.3.1.3.4.4
Name or IP address of the TCP server which accepts the system trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPSnmpSystemTrapEnable 1.3.6.1.4.1.5040.1.2.25.3.1.3.4.5
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag messages Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERPUdpAdminPort 1.3.6.1.4.1.5040.1.2.25.3.1.3.5.1
Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERPUdpEnable 1.3.6.1.4.1.5040.1.2.25.3.1.3.5.2
Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPUdpRemotePort 1.3.6.1.4.1.5040.1.2.25.3.1.3.5.3
Udp remote port setting. If this value is set to zero, the source port read from a request will be used as destination port for the answer. A non zero value forced the destination port to this value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERPBinaryModeCount 1.3.6.1.4.1.5040.1.2.25.3.1.3.6.1
Number of independent binary channels.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtWebioEA2x2ERPBinaryIfTable 1.3.6.1.4.1.5040.1.2.25.3.1.3.6.2
Table of indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2ERPBinaryIfEntry

wtWebioEA2x2ERPBinaryIfEntry 1.3.6.1.4.1.5040.1.2.25.3.1.3.6.2.1
Indices of the binary channels.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2ERPBinaryIfEntry  

wtWebioEA2x2ERPBinaryModeNo 1.3.6.1.4.1.5040.1.2.25.3.1.3.6.2.1.1
Number of the binary channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtWebioEA2x2ERPBinaryTable 1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3
Table of properties of the binary mode.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2ERPBinaryEntry

wtWebioEA2x2ERPBinaryEntry 1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1
Binary properties.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2ERPBinaryEntry  

wtWebioEA2x2ERPBinaryOperationMode 1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.1
Selection of the operation mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : UDP Peer Bit 1 : TCP Client Bit 0 : TCP Server
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERPBinaryTcpServerLocalPort 1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.2
Local TCP port for data exchange in this server mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2ERPBinaryTcpServerInputTrigger 1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.3
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERPBinaryTcpServerApplicationMode 1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.4
Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 4-7: unused Bit 3 : OPC Device Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERPBinaryTcpClientLocalPort 1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.5
Local TCP port for data exchange in this client mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2ERPBinaryTcpClientServerPort 1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.6
Port number of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server port to zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2ERPBinaryTcpClientServerIpAddr 1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.7
Ip address of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server IP address to 0.0.0.0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPBinaryTcpClientServerPassword 1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.8
Building a connection may be protected by the administrator password of the server. Enter the server password to establish the connection, if a server administrator password exists.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPBinaryTcpClientInactivity 1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.9
Connection timeout in 100ms. If no data are exchanged within the specified time, the device closes the connection to the server. The value 0 deactivates the timer. Using the Box2Box mode this function is disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERPBinaryTcpClientInputTrigger 1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.10
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERPBinaryTcpClientInterval 1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.11
Configurable interval with a 100ms base, in which the Webio device sends data to the configured application. A interval of zero stopps the periodical sending.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA2x2ERPBinaryTcpClientApplicationMode 1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.12
Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERPBinaryUdpPeerLocalPort 1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.13
Local UDP port for data exchange in this peer to peer mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2ERPBinaryUdpPeerRemotePort 1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.14
Port number of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote port to zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2ERPBinaryUdpPeerRemoteIpAddr 1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.15
Ip address of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote device IP address to 0.0.0.0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPBinaryUdpPeerInputTrigger 1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.16
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERPBinaryUdpPeerInterval 1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.17
Configurable interval with a 100ms base, in which the Webio device sends data to the configured remote device. A interval of zero stopps the periodical sending.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA2x2ERPBinaryUdpPeerApplicationMode 1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.18
Selection of the application mode: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERPBinaryConnectedPort 1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.19
Port number of the remote device, after connection has been established. In case of no connection or missing port informations a zero will be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2ERPBinaryConnectedIpAddr 1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.20
IP address of the remote device, after connection has been established. In case of no connection or missing port informations 0.0.0.0 will be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

wtWebioEA2x2ERPBinaryTcpServerClientHttpPort 1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.21
HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs status informations will be send to this port. Not used at mode Compatible 50xxx.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2ERPBinaryTcpClientServerHttpPort 1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.22
HTTP port number of the remote device at TCP Client Mode. In the operating mode Box2Box connection status informations will be exchanged through this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2ERPSyslogServerIP 1.3.6.1.4.1.5040.1.2.25.3.1.3.7.1
Name or IP address of the Syslog server, which accepts the Syslog messgaes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPSyslogServerPort 1.3.6.1.4.1.5040.1.2.25.3.1.3.7.2
Portnumber of the Syslog servers, default 514.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERPSyslogSystemMessagesEnable 1.3.6.1.4.1.5040.1.2.25.3.1.3.7.3
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERPSyslogEnable 1.3.6.1.4.1.5040.1.2.25.3.1.3.7.4
Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPFTPServerIP 1.3.6.1.4.1.5040.1.2.25.3.1.3.8.1
Name or IP address of the FTP server, which accepts the FTP messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPFTPServerControlPort 1.3.6.1.4.1.5040.1.2.25.3.1.3.8.2
Portnumber of the control port of the FTP server, default 21.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERPFTPUserName 1.3.6.1.4.1.5040.1.2.25.3.1.3.8.3
FTP Loggin: user name.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPFTPPassword 1.3.6.1.4.1.5040.1.2.25.3.1.3.8.4
FTP Loggin: user password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPFTPAccount 1.3.6.1.4.1.5040.1.2.25.3.1.3.8.5
FTP Loggin: name of account.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPFTPOption 1.3.6.1.4.1.5040.1.2.25.3.1.3.8.6
Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPFTPEnable 1.3.6.1.4.1.5040.1.2.25.3.1.3.8.7
Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPWayBackEnable 1.3.6.1.4.1.5040.1.2.25.3.1.3.10.1
Set Bit 0 to enable WayBack: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : WayBack enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPWayBackServerControlPort 1.3.6.1.4.1.5040.1.2.25.3.1.3.10.2
Portnumber of the control port of the FTP server, default 21.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERPWayBackFTPPassword 1.3.6.1.4.1.5040.1.2.25.3.1.3.10.3
WayBack FTP Loggin: Password of the user.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPWayBackFTPResponse 1.3.6.1.4.1.5040.1.2.25.3.1.3.10.4
WayBack FTP response: return message after login.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPWayBackFTPTimeOut 1.3.6.1.4.1.5040.1.2.25.3.1.3.10.5
WayBack FTP Timeout: a request must be finished within this periode of time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPOutputModeTable 1.3.6.1.4.1.5040.1.2.25.3.1.4.1
Table of output mode configurations dependent on the output indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2ERPOutputModeEntry

wtWebioEA2x2ERPOutputModeEntry 1.3.6.1.4.1.5040.1.2.25.3.1.4.1.1
Output mode configurations of the individual outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2ERPOutputModeEntry  

wtWebioEA2x2ERPOutputModeBit 1.3.6.1.4.1.5040.1.2.25.3.1.4.1.1.1
This binary coded output mode defines the individual operation mode for any output. More than one mode must not be selected. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 6-7: unused Bit 5 : Logic Bit 4 : Binary 2 Bit 3 : Binary 1 Bit 2 : SNMP Bit 1 : UDP ASCII Bit 0 : HTTP
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERPSafetyTimeout 1.3.6.1.4.1.5040.1.2.25.3.1.4.2
After this period of time (multiple of 100ms) without receiving data outputs switch to their Safety States. For each output a independend safety state could be defined.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA2x2ERPLoadControlEnable 1.3.6.1.4.1.5040.1.2.25.3.1.4.3
Here the function of automatic load control can be enabled. All output were tested in pairs (0-1). If an error occours at one output, both output of an pair will be switched of. For a properly function of the load control each output of a pair have to has a load. If there is no existing load, a pull down resistor can be used. Outputs with no load are automaticly detected and not part of the control function. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Load Control enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPAlarmCount 1.3.6.1.4.1.5040.1.2.25.3.1.5.1
Number of independent alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

wtWebioEA2x2ERPAlarmIfTable 1.3.6.1.4.1.5040.1.2.25.3.1.5.2
List of alarm indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2ERPAlarmIfEntry

wtWebioEA2x2ERPAlarmIfEntry 1.3.6.1.4.1.5040.1.2.25.3.1.5.2.1
Numbers of the alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2ERPAlarmIfEntry  

wtWebioEA2x2ERPAlarmNo 1.3.6.1.4.1.5040.1.2.25.3.1.5.2.1.1
Numbers of the alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

wtWebioEA2x2ERPAlarmTable 1.3.6.1.4.1.5040.1.2.25.3.1.5.3
List of settings depending on the alarm number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2ERPAlarmEntry

wtWebioEA2x2ERPAlarmEntry 1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1
Alarm parameters of the individual alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2ERPAlarmEntry  

wtWebioEA2x2ERPAlarmInputTrigger 1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.1
This variable allows setting of individual input trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the inputs are to be considered (corresponding bit = 1) and which inputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital inputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital inputs 0-1 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change of the corresponding input bit. Settings in OCTET 5-9 are then unused: OCTET 9: unused OCTET 10: unused OCTET 11: unused OCTET 12, Bit 0-1: ANY bits of digital inputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(12)  

wtWebioEA2x2ERPAlarmOutputTrigger 1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.2
This variable allows setting of individual output trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be considered (corresponding bit = 1) and which outputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital outputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital outputs 0-1 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change of the corresponding output bit. Settings in OCTET 5-9 are then unused: OCTET 9: unused OCTET 10: unused OCTET 11: unused OCTET 12, Bit 0-1: ANY bits of digital outputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(12)  

wtWebioEA2x2ERPAlarmSystemTrigger 1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.3
Binary coded trigger conditions: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Warm Start Bit 2 : Cold Start Bit 1 : Timer Bit 0 : Load Control
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERPAlarmMaxCounterValue 1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.4
This variable configures a max. counter value. If an input counter value exceeds this max. value, the corresponding alarm is triggered. Input counters with its mask bit unset in wtWebioEA2x2ERPAlarmInputTrigger are not considered.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPAlarmInterval 1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.5
Send interval for alarm messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPAlarmEnable 1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.6
Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: UDP enable Bit 3: Send inputs to pending TCP connections Bit 4: TCP Client enable Bit 5: Syslog Messages enable Bit 6-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERPAlarmMailAddr 1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.7
E-Mail address for sending the alarm mail to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPAlarmMailSubject 1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.8
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPAlarmMailText 1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.9
Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPAlarmSnmpManagerIP 1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.10
IP address of the SNMP Manager to which the Webio device should send SNMP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPAlarmSnmpTrapText 1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.11
This text appears in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPAlarmUdpIpAddr 1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.12
IP address of the UDP listener to which the Webio device should send UDP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPAlarmUdpPort 1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.13
Port number of the UDP listener to which the Webio device should send UDP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2ERPAlarmUdpText 1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.14
This text appears in the UDP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPAlarmTcpIpAddr 1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.15
IP address of the TCP listener to which the Webio device should send TCP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPAlarmTcpPort 1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.16
Port number of the TCP listener to which the Webio device should send TCP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2ERPAlarmTcpText 1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.17
This text appears in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPAlarmSyslogIpAddr 1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.18
IP address of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPAlarmSyslogPort 1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.19
Port number of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2ERPAlarmSyslogText 1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.20
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPAlarmFtpDataPort 1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.21
Local data port: 1..65535 or AUTO: the next free port will be assigned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPAlarmFtpFileName 1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.22
Name of the file including path informations.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPAlarmFtpText 1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.23
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPAlarmFtpOption 1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.24
Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERPAlarmTimerCron 1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.25
This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPAlarmMailReleaseSubject 1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.26
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPAlarmMailReleaseText 1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.27
Release Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPAlarmSnmpTrapReleaseText 1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.28
This text appears in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPAlarmUdpReleaseText 1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.29
This text appears in the UDP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPAlarmTcpReleaseText 1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.30
This text appears in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPAlarmSyslogReleaseText 1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.31
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPAlarmFtpReleaseText 1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.32
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPLoadControlView 1.3.6.1.4.1.5040.1.2.25.3.1.5.4
Here the result of automatic load control can be read. All output were tested in pairs (0-1). If an error occours at one output, both output of an pair will be switched of. For a properly function of the load control each output of a pair have to has a load. If there is no existing load, a pull down resistor can be used. Outputs with no load are automaticly detected and not part of the control function. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0-1: outputs 0-1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERPLCShutDownView 1.3.6.1.4.1.5040.1.2.25.3.1.5.5
Here the result of the automatic load control shut down can be read. All outputs remain switched of, until a zero is written into this variable. But previously all loads should be inspected. High current (short circuit), a broken supply line or a defect load (i.e. lamp) may be a shut down reason. If no load is detected, the load control unit suspend automaticly the control of the corresponding output pair. All controlled output could be identified reading the variable wtWebioEA2x2ERPLoadControlEnable. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an ouput. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0-1: outputs 0-1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERPInputPortTable 1.3.6.1.4.1.5040.1.2.25.3.2.1
List of settings depending on the input number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2ERPInputPortEntry

wtWebioEA2x2ERPInputPortEntry 1.3.6.1.4.1.5040.1.2.25.3.2.1.1
Input parameter for the individual inputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2ERPInputPortEntry  

wtWebioEA2x2ERPPortInputName 1.3.6.1.4.1.5040.1.2.25.3.2.1.1.1
Name of the input.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPPortInputText 1.3.6.1.4.1.5040.1.2.25.3.2.1.1.2
Description of the input.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPPortInputMode 1.3.6.1.4.1.5040.1.2.25.3.2.1.1.3
Binary coded modes: Selecting short pulse detection enable by setting the corresponding bit to 1 enables interrupt support for counting. Only positive edges are accepted as trigger source. The maximum counting frequenz equals 2000 Hz. This mode is available for inputs 0-3 only. Selecting counter clear on read by setting the corresponding bit to 1 enables the corresponding counter to be cleared automatically every time it is read, except HTTP reading with user rights. The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. Selection for input 0-1: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Bidirectional counter enable Bit 2 : Counter clear on read Bit 1 : Change detection enable (default) Bit 0 : Short Pulse detection enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERPPortInputFilter 1.3.6.1.4.1.5040.1.2.25.3.2.1.1.4
Pulses with a duration shorter than here specified (duration in 1/1000 sec), are ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERPPortInputBicountPulsePolarity 1.3.6.1.4.1.5040.1.2.25.3.2.1.1.5
This value defines the polarity of the input pulse. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERPPortInputBicountInactivTimeout 1.3.6.1.4.1.5040.1.2.25.3.2.1.1.6
Pulse chains with a duration shorter than here specified (in 1/10 sek), are ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERPOutputPortTable 1.3.6.1.4.1.5040.1.2.25.3.2.2
List of settings depending on the output number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2ERPOutputPortEntry

wtWebioEA2x2ERPOutputPortEntry 1.3.6.1.4.1.5040.1.2.25.3.2.2.1
Output parameters of the individual outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2ERPOutputPortEntry  

wtWebioEA2x2ERPPortOutputName 1.3.6.1.4.1.5040.1.2.25.3.2.2.1.1
Name of the output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPPortOutputText 1.3.6.1.4.1.5040.1.2.25.3.2.2.1.2
Description of the output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPPortOutputGroupMode 1.3.6.1.4.1.5040.1.2.25.3.2.2.1.3
It is possible to connect outputs together to increase the output current. This could be done by connecting 2 or 4 outputs in a group together. All bits of such a group has to be set all together in the same way. This variable configures this group scheme. If one ouput bit of a group is set, all other output bits of the same group will be set in the same manner. More than one configuration must not be selected. Selection for ouputs 0-1: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: Bit 0 : ouputs 0,1 disconnected (default) Bit 1 : ouputs 0+1 connected
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPPortOutputSafetyState 1.3.6.1.4.1.5040.1.2.25.3.2.2.1.4
This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 1-7: unused Bit 0 : Mask for digital output OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs to be changed should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 1-7: unused Bit 0 : Level of digital output
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPPortLogicInputMask 1.3.6.1.4.1.5040.1.2.25.3.2.2.1.5
Selecting one of these inputs by setting the corresponding bit to 1 enables the logic function for the output identified by the index within this table. The calculation take place in 4 steps: 1. Selecting inputs (wtWebioEA2x2ERPPortLogicInputMask) 2. Inverting inputs if necessary (wtWebioEA2x2ERPPortLogicInputInverter) 3. Logical combination (wtWebioEA2x2ERPPortLogicFunction) 4. Inverting the result if necessary (wtWebioEA2x2ERPPortLogicOutputInverter) OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0-1 : inputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERPPortLogicInputInverter 1.3.6.1.4.1.5040.1.2.25.3.2.2.1.6
Every input bit selected here will be inverted. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0-1 : inputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERPPortLogicFunction 1.3.6.1.4.1.5040.1.2.25.3.2.2.1.7
This determines the logic function. No more than one function may be selected. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : logic function OR (default) Bit 1 : logic function AND Bit 2-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERPPortLogicOutputInverter 1.3.6.1.4.1.5040.1.2.25.3.2.2.1.8
The logical operation result could be inverteted by setting the corresponding bit to 1. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : Output Inverter enable Bit 1-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERPPortPulseDuration 1.3.6.1.4.1.5040.1.2.25.3.2.2.1.9
Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERPPortPulsePolarity 1.3.6.1.4.1.5040.1.2.25.3.2.2.1.10
This value defines the polarity of the output pulse, if wtWebioEA2x2ERPPortPulseDuration is not set to zero. After the pulse is finished, the output switches back to the opposite state. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERPMfName 1.3.6.1.4.1.5040.1.2.25.3.3.1
Manufacturer company name
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPMfAddr 1.3.6.1.4.1.5040.1.2.25.3.3.2
Manufacturer address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPMfHotline 1.3.6.1.4.1.5040.1.2.25.3.3.3
Manufacturer hotline.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPMfInternet 1.3.6.1.4.1.5040.1.2.25.3.3.4
Manufacturer Internet address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPMfDeviceTyp 1.3.6.1.4.1.5040.1.2.25.3.3.5
Manufacturer device name (model number).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPDiagErrorCount 1.3.6.1.4.1.5040.1.2.25.4.1
Number of entries in the error memory.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERPDiagBinaryError 1.3.6.1.4.1.5040.1.2.25.4.2
Error causes coded bit-by-bit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPDiagErrorIndex 1.3.6.1.4.1.5040.1.2.25.4.3
The value of this variable is used as an index to read an error massege from wtWebioEA2x2ERPDiagErrorMessage. Errors are numbered from 1 to wtWebioEA2x2ERPDiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebioEA2x2ERPDiagErrorMessage.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERPDiagErrorMessage 1.3.6.1.4.1.5040.1.2.25.4.4
Using wtWebioEA2x2ERPDiagErrorIndex as an index, the appropriate message is available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERPDiagErrorClear 1.3.6.1.4.1.5040.1.2.25.4.5
Writing 1 into this variable clears all diagnosis messages.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERPAlert1 41
This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERPAlert2 42
This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERPAlert3 43
This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERPAlert4 44
This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERPAlert5 45
This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERPAlert6 46
This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERPAlert7 47
This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERPAlert8 48
This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERPAlert9 49
This SNMP trap is generated when Alarm 9 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERPAlert10 50
This SNMP trap is generated when Alarm 10 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERPAlert11 51
This SNMP trap is generated when Alarm 11 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERPAlert12 52
This SNMP trap is generated when Alarm 12 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERPAlert13 71
This SNMP trap is generated when Alarm 1 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERPAlert14 72
This SNMP trap is generated when Alarm 2 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERPAlert15 73
This SNMP trap is generated when Alarm 3 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERPAlert16 74
This SNMP trap is generated when Alarm 4 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERPAlert17 75
This SNMP trap is generated when Alarm 5 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERPAlert18 76
This SNMP trap is generated when Alarm 6 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERPAlert19 77
This SNMP trap is generated when Alarm 7 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERPAlert20 78
This SNMP trap is generated when Alarm 8 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERPAlert21 79
This SNMP trap is generated when Alarm 9 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERPAlert22 80
This SNMP trap is generated when Alarm 10 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERPAlert23 81
This SNMP trap is generated when Alarm 11 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERPAlert24 82
This SNMP trap is generated when Alarm 12 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERPAlertDiag 110
This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelERPInputs 1.3.6.1.4.1.5040.1.2.26.1.1
Number of idependent inputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..12  

wtWebioEA12x6RelERPOutputs 1.3.6.1.4.1.5040.1.2.26.1.2
Number of independent outputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..6  

wtWebioEA12x6RelERPInputTable 1.3.6.1.4.1.5040.1.2.26.1.3
List of input indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA12x6RelERPInputEntry

wtWebioEA12x6RelERPInputEntry 1.3.6.1.4.1.5040.1.2.26.1.3.1
Number of the inputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA12x6RelERPInputEntry  

wtWebioEA12x6RelERPInputNo 1.3.6.1.4.1.5040.1.2.26.1.3.1.1
Index numbers of the inputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebioEA12x6RelERPInputCounter 1.3.6.1.4.1.5040.1.2.26.1.3.1.2
Value of the input counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebioEA12x6RelERPInputCounterClear 1.3.6.1.4.1.5040.1.2.26.1.3.1.3
Clears the input counter after returning its value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelERPInputValue 1.3.6.1.4.1.5040.1.2.26.1.4
This variable is used to read the inputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, Bit 0-3: Digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Digital inputs 0-7
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelERPOutputTable 1.3.6.1.4.1.5040.1.2.26.1.5
List of output indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA12x6RelERPOutputEntry

wtWebioEA12x6RelERPOutputEntry 1.3.6.1.4.1.5040.1.2.26.1.5.1
Number of the outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA12x6RelERPOutputEntry  

wtWebioEA12x6RelERPOutputNo 1.3.6.1.4.1.5040.1.2.26.1.5.1.1
Output number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebioEA12x6RelERPOutputState 1.3.6.1.4.1.5040.1.2.26.1.5.1.2
Setting and reading of the states of the outputs.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA12x6RelERPOutputState-OFF(0), wtWebioEA12x6OutputState-ON(1)  

wtWebioEA12x6RelERPOutputValue 1.3.6.1.4.1.5040.1.2.26.1.6
This variable is used to read and write the outputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0-5: Digital outputs 0-5
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelERPSetOutput 1.3.6.1.4.1.5040.1.2.26.1.7
This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first two OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4 : Bit 0-5: Mask for digital outputs 0-5 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8 : Bit 0-5: Level of digital outputs 0-5
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

wtWebioEA12x6RelERPSessCntrlPassword 1.3.6.1.4.1.5040.1.2.26.2.1
Entering this password opens a session which is ended by writing a 1 to wtWebioEA12x6RelERPSessCntrlLogout. When read this variable provides a string of length zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPSessCntrlConfigMode 1.3.6.1.4.1.5040.1.2.26.2.2
When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtWebioEA12x6RelERPSessCntrl-NoSession(0), wtWebioEA12x6RelERPSessCntrl-Session(1)  

wtWebioEA12x6RelERPSessCntrlLogout 1.3.6.1.4.1.5040.1.2.26.2.3
If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelERPSessCntrlAdminPassword 1.3.6.1.4.1.5040.1.2.26.2.4
This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPSessCntrlConfigPassword 1.3.6.1.4.1.5040.1.2.26.2.5
This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPDeviceName 1.3.6.1.4.1.5040.1.2.26.3.1.1.1
Name of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPDeviceText 1.3.6.1.4.1.5040.1.2.26.3.1.1.2
Description of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPDeviceLocation 1.3.6.1.4.1.5040.1.2.26.3.1.1.3
Description of the location of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPDeviceContact 1.3.6.1.4.1.5040.1.2.26.3.1.1.4
Contact address of the system operator of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPTzOffsetHrs 1.3.6.1.4.1.5040.1.2.26.3.1.2.1.1
Offset hours for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelERPTzOffsetMin 1.3.6.1.4.1.5040.1.2.26.3.1.2.1.2
Offset minutes for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelERPTzEnable 1.3.6.1.4.1.5040.1.2.26.3.1.2.1.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelERPStTzOffsetHrs 1.3.6.1.4.1.5040.1.2.26.3.1.2.1.4
Offset hours of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelERPStTzOffsetMin 1.3.6.1.4.1.5040.1.2.26.3.1.2.1.5
Offset minutes of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelERPStTzEnable 1.3.6.1.4.1.5040.1.2.26.3.1.2.1.6
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelERPStTzStartMonth 1.3.6.1.4.1.5040.1.2.26.3.1.2.1.7
Month in which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA12x6RelERPStartMonth-January(1), wtWebioEA12x6RelERPStartMonth-February(2), wtWebioEA12x6RelERPStartMonth-March(3), wtWebioEA12x6RelERPStartMonth-April(4), wtWebioEA12x6RelERPStartMonth-May(5), wtWebioEA12x6RelERPStartMonth-June(6), wtWebioEA12x6RelERPStartMonth-July(7), wtWebioEA12x6RelERPStartMonth-August(8), wtWebioEA12x6RelERPStartMonth-September(9), wtWebioEA12x6RelERPStartMonth-October(10), wtWebioEA12x6RelERPStartMonth-November(11), wtWebioEA12x6RelERPStartMonth-December(12)  

wtWebioEA12x6RelERPStTzStartMode 1.3.6.1.4.1.5040.1.2.26.3.1.2.1.8
Mode of the day of the week for which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA12x6RelERPStartMode-first(1), wtWebioEA12x6RelERPStartMode-second(2), wtWebioEA12x6RelERPStartMode-third(3), wtWebioEA12x6RelERPStartMode-fourth(4), wtWebioEA12x6RelERPStartMode-last(5)  

wtWebioEA12x6RelERPStTzStartWday 1.3.6.1.4.1.5040.1.2.26.3.1.2.1.9
Day of the week on which the change is made from winter time to summer time
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA12x6RelERPStartWday-Sunday(1), wtWebioEA12x6RelERPStartWday-Monday(2), wtWebioEA12x6RelERPStartWday-Tuesday(3), wtWebioEA12x6RelERPStartWday-Thursday(4), wtWebioEA12x6RelERPStartWday-Wednesday(5), wtWebioEA12x6RelERPStartWday-Friday(6), wtWebioEA12x6RelERPStartWday-Saturday(7)  

wtWebioEA12x6RelERPStTzStartHrs 1.3.6.1.4.1.5040.1.2.26.3.1.2.1.10
Hour in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelERPStTzStartMin 1.3.6.1.4.1.5040.1.2.26.3.1.2.1.11
Minute in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelERPStTzStopMonth 1.3.6.1.4.1.5040.1.2.26.3.1.2.1.12
Month in which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA12x6RelERPStopMonth-January(1), wtWebioEA12x6RelERPStopMonth-February(2), wtWebioEA12x6RelERPStopMonth-March(3), wtWebioEA12x6RelERPStopMonth-April(4), wtWebioEA12x6RelERPStopMonth-May(5), wtWebioEA12x6RelERPStopMonth-June(6), wtWebioEA12x6RelERPStopMonth-July(7), wtWebioEA12x6RelERPStopMonth-August(8), wtWebioEA12x6RelERPStopMonth-September(9), wtWebioEA12x6RelERPStopMonth-October(10), wtWebioEA12x6RelERPStopMonth-November(11), wtWebioEA12x6RelERPStopMonth-December(12)  

wtWebioEA12x6RelERPStTzStopMode 1.3.6.1.4.1.5040.1.2.26.3.1.2.1.13
Mode of the week day on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA12x6RelERPStopMode-first(1), wtWebioEA12x6RelERPStopMode-second(2), wtWebioEA12x6RelERPStopMode-third(3), wtWebioEA12x6RelERPStopMode-fourth(4), wtWebioEA12x6RelERPStopMode-last(5)  

wtWebioEA12x6RelERPStTzStopWday 1.3.6.1.4.1.5040.1.2.26.3.1.2.1.14
Day of the week on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA12x6RelERPStopWday-Sunday(1), wtWebioEA12x6RelERPStopWday-Monday(2), wtWebioEA12x6RelERPStopWday-Tuesday(3), wtWebioEA12x6RelERPStopWday-Thursday(4), wtWebioEA12x6RelERPStopWday-Wednesday(5), wtWebioEA12x6RelERPStopWday-Friday(6), wtWebioEA12x6RelERPStopWday-Saturday(7)  

wtWebioEA12x6RelERPStTzStopHrs 1.3.6.1.4.1.5040.1.2.26.3.1.2.1.15
Hour at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelERPStTzStopMin 1.3.6.1.4.1.5040.1.2.26.3.1.2.1.16
Minute at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelERPTimeServer1 1.3.6.1.4.1.5040.1.2.26.3.1.2.2.1
IP address or name of the 1st time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPTimeServer2 1.3.6.1.4.1.5040.1.2.26.3.1.2.2.2
IP address or name of the 2nd time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPTsEnable 1.3.6.1.4.1.5040.1.2.26.3.1.2.2.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelERPTsSyncTime 1.3.6.1.4.1.5040.1.2.26.3.1.2.2.4
Daily synchronisation time with the time server (hour: 0-23).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelERPClockHrs 1.3.6.1.4.1.5040.1.2.26.3.1.2.3.1
Clock hours taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..23  

wtWebioEA12x6RelERPClockMin 1.3.6.1.4.1.5040.1.2.26.3.1.2.3.2
Clock minutes taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..59  

wtWebioEA12x6RelERPClockDay 1.3.6.1.4.1.5040.1.2.26.3.1.2.3.3
Date: Day of the month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..31  

wtWebioEA12x6RelERPClockMonth 1.3.6.1.4.1.5040.1.2.26.3.1.2.3.4
Date: Month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA12x6RelERPClockMonth-January(1), wtWebioEA12x6RelERPClockMonth-February(2), wtWebioEA12x6RelERPClockMonth-March(3), wtWebioEA12x6RelERPClockMonth-April(4), wtWebioEA12x6RelERPClockMonth-May(5), wtWebioEA12x6RelERPClockMonth-June(6), wtWebioEA12x6RelERPClockMonth-July(7), wtWebioEA12x6RelERPClockMonth-August(8), wtWebioEA12x6RelERPClockMonth-September(9), wtWebioEA12x6RelERPClockMonth-October(10), wtWebioEA12x6RelERPClockMonth-November(11), wtWebioEA12x6RelERPClockMonth-December(12)  

wtWebioEA12x6RelERPClockYear 1.3.6.1.4.1.5040.1.2.26.3.1.2.3.5
Date: Year, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA12x6RelERPIpAddress 1.3.6.1.4.1.5040.1.2.26.3.1.3.1.1
IP address of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioEA12x6RelERPSubnetMask 1.3.6.1.4.1.5040.1.2.26.3.1.3.1.2
Subnet mask of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioEA12x6RelERPGateway 1.3.6.1.4.1.5040.1.2.26.3.1.3.1.3
Gateway of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioEA12x6RelERPDnsServer1 1.3.6.1.4.1.5040.1.2.26.3.1.3.1.4
IP address of the 1st DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPDnsServer2 1.3.6.1.4.1.5040.1.2.26.3.1.3.1.5
IP address of the 2nd DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPAddConfig 1.3.6.1.4.1.5040.1.2.26.3.1.3.1.6
Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP enable Bit 0: BOOTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPStartup 1.3.6.1.4.1.5040.1.2.26.3.1.3.2.1
Binary coded start page, more than one page must not be selected: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2: user.htm Bit 1: home.htm Bit 0: index.htm
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPGetHeaderEnable 1.3.6.1.4.1.5040.1.2.26.3.1.3.2.2
If bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device (Header) or a HTTP header (HTTP): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2-7: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPHttpInputTrigger 1.3.6.1.4.1.5040.1.2.26.3.1.3.2.3
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, Bit 0-3: Digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Digital inputs 0-7
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelERPHttpPort 1.3.6.1.4.1.5040.1.2.26.3.1.3.2.4
Definition of the standard HTML port (Default: 80).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65534  

wtWebioEA12x6RelERPMailAdName 1.3.6.1.4.1.5040.1.2.26.3.1.3.3.1
Device name for mail administration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPMailReply 1.3.6.1.4.1.5040.1.2.26.3.1.3.3.2
Reply address for the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPMailServer 1.3.6.1.4.1.5040.1.2.26.3.1.3.3.3
Name or IP address of the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPMailEnable 1.3.6.1.4.1.5040.1.2.26.3.1.3.3.4
Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPMailAuthentication 1.3.6.1.4.1.5040.1.2.26.3.1.3.3.5
Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelERPMailAuthUser 1.3.6.1.4.1.5040.1.2.26.3.1.3.3.6
Name of the user to be authenticated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPMailAuthPassword 1.3.6.1.4.1.5040.1.2.26.3.1.3.3.7
Authentication password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPMailPop3Server 1.3.6.1.4.1.5040.1.2.26.3.1.3.3.8
Name or Ip-address of the POP3 Servers.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPSnmpEnable 1.3.6.1.4.1.5040.1.2.26.3.1.3.4.1
Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPSnmpCommunityStringRead 1.3.6.1.4.1.5040.1.2.26.3.1.3.4.2
Community string read only
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPSnmpCommunityStringReadWrite 1.3.6.1.4.1.5040.1.2.26.3.1.3.4.3
Community string read / write
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPSnmpSystemTrapManagerIP 1.3.6.1.4.1.5040.1.2.26.3.1.3.4.4
Name or IP address of the TCP server which accepts the system trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPSnmpSystemTrapEnable 1.3.6.1.4.1.5040.1.2.26.3.1.3.4.5
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag messages Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelERPUdpAdminPort 1.3.6.1.4.1.5040.1.2.26.3.1.3.5.1
Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelERPUdpEnable 1.3.6.1.4.1.5040.1.2.26.3.1.3.5.2
Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPUdpRemotePort 1.3.6.1.4.1.5040.1.2.26.3.1.3.5.3
Udp remote port setting. If this value is set to zero, the source port read from a request will be used as destination port for the answer. A non zero value forced the destination port to this value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelERPBinaryModeCount 1.3.6.1.4.1.5040.1.2.26.3.1.3.6.1
Number of independent binary channels.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtWebioEA12x6RelERPBinaryIfTable 1.3.6.1.4.1.5040.1.2.26.3.1.3.6.2
Table of indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA12x6RelERPBinaryIfEntry

wtWebioEA12x6RelERPBinaryIfEntry 1.3.6.1.4.1.5040.1.2.26.3.1.3.6.2.1
Indices of the binary channels.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA12x6RelERPBinaryIfEntry  

wtWebioEA12x6RelERPBinaryModeNo 1.3.6.1.4.1.5040.1.2.26.3.1.3.6.2.1.1
Number of the binary channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtWebioEA12x6RelERPBinaryTable 1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3
Table of properties of the binary mode.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA12x6RelERPBinaryEntry

wtWebioEA12x6RelERPBinaryEntry 1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1
Binary properties.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA12x6RelERPBinaryEntry  

wtWebioEA12x6RelERPBinaryOperationMode 1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.1
Selection of the operation mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : UDP Peer Bit 1 : TCP Client Bit 0 : TCP Server
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelERPBinaryTcpServerLocalPort 1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.2
Local TCP port for data exchange in this server mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA12x6RelERPBinaryTcpServerInputTrigger 1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.3
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, Bit 0-3: Digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Digital inputs 0-7
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelERPBinaryTcpServerApplicationMode 1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.4
Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 4-7: unused Bit 3 : OPC Device Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelERPBinaryTcpClientLocalPort 1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.5
Local TCP port for data exchange in this client mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA12x6RelERPBinaryTcpClientServerPort 1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.6
Port number of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server port to zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA12x6RelERPBinaryTcpClientServerIpAddr 1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.7
Ip address of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server IP address to 0.0.0.0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPBinaryTcpClientServerPassword 1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.8
Building a connection may be protected by the administrator password of the server. Enter the server password to establish the connection, if a server administrator password exists.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPBinaryTcpClientInactivity 1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.9
Connection timeout in 100ms. If no data are exchanged within the specified time, the device closes the connection to the server. The value 0 deactivates the timer. Using the Box2Box mode this function is disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelERPBinaryTcpClientInputTrigger 1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.10
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, Bit 0-3: Digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Digital inputs 0-7
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelERPBinaryTcpClientInterval 1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.11
Configurable interval with a 100ms base, in which the Webio device sends data to the configured application. A interval of zero stopps the periodical sending.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA12x6RelERPBinaryTcpClientApplicationMode 1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.12
Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelERPBinaryUdpPeerLocalPort 1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.13
Local UDP port for data exchange in this peer to peer mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA12x6RelERPBinaryUdpPeerRemotePort 1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.14
Port number of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote port to zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA12x6RelERPBinaryUdpPeerRemoteIpAddr 1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.15
Ip address of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote device IP address to 0.0.0.0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPBinaryUdpPeerInputTrigger 1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.16
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3, Bit 0-3: Digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Digital inputs 0-7
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelERPBinaryUdpPeerInterval 1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.17
Configurable interval with a 100ms base, in which the Webio device sends data to the configured remote device. A interval of zero stopps the periodical sending.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA12x6RelERPBinaryUdpPeerApplicationMode 1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.18
Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelERPBinaryConnectedPort 1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.19
Port number of the remote device, after connection has been established. In case of no connection or missing port informations a zero will be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA12x6RelERPBinaryConnectedIpAddr 1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.20
IP address of the remote device, after connection has been established. In case of no connection or missing port informations 0.0.0.0 will be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

wtWebioEA12x6RelERPBinaryTcpServerClientHttpPort 1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.21
HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs status informations will be send to this port. Not used at mode Compatible 50xxx.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA12x6RelERPBinaryTcpClientServerHttpPort 1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.22
HTTP port number of the remote device at TCP Client Mode. In the operating mode Box2Box connection status informations will be exchanged through this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA12x6RelERPSyslogServerIP 1.3.6.1.4.1.5040.1.2.26.3.1.3.7.1
Name or IP address of the Syslog server, which accepts the Syslog messgaes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPSyslogServerPort 1.3.6.1.4.1.5040.1.2.26.3.1.3.7.2
Portnumber of the Syslog servers, default 514.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelERPSyslogSystemMessagesEnable 1.3.6.1.4.1.5040.1.2.26.3.1.3.7.3
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelERPSyslogEnable 1.3.6.1.4.1.5040.1.2.26.3.1.3.7.4
Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPFTPServerIP 1.3.6.1.4.1.5040.1.2.26.3.1.3.8.1
Name or IP address of the FTP server, which accepts the FTP messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPFTPServerControlPort 1.3.6.1.4.1.5040.1.2.26.3.1.3.8.2
Portnumber of the control port of the FTP server, default 21.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelERPFTPUserName 1.3.6.1.4.1.5040.1.2.26.3.1.3.8.3
FTP Loggin: user name.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPFTPPassword 1.3.6.1.4.1.5040.1.2.26.3.1.3.8.4
FTP Loggin: user password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPFTPAccount 1.3.6.1.4.1.5040.1.2.26.3.1.3.8.5
FTP Loggin: name of account.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPFTPOption 1.3.6.1.4.1.5040.1.2.26.3.1.3.8.6
Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPFTPEnable 1.3.6.1.4.1.5040.1.2.26.3.1.3.8.7
Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPWayBackEnable 1.3.6.1.4.1.5040.1.2.26.3.1.3.10.1
Set Bit 0 to enable WayBack: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : WayBack enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPWayBackServerControlPort 1.3.6.1.4.1.5040.1.2.26.3.1.3.10.2
Portnumber of the control port of the FTP server, default 21.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelERPWayBackFTPPassword 1.3.6.1.4.1.5040.1.2.26.3.1.3.10.3
WayBack FTP Loggin: Password of the user.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPWayBackFTPResponse 1.3.6.1.4.1.5040.1.2.26.3.1.3.10.4
WayBack FTP response: return message after login.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPWayBackFTPTimeOut 1.3.6.1.4.1.5040.1.2.26.3.1.3.10.5
WayBack FTP Timeout: a request must be finished within this periode of time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPOutputModeTable 1.3.6.1.4.1.5040.1.2.26.3.1.4.1
Table of output mode configurations dependent on the output indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA12x6RelERPOutputModeEntry

wtWebioEA12x6RelERPOutputModeEntry 1.3.6.1.4.1.5040.1.2.26.3.1.4.1.1
Output mode configurations of the individual outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA12x6RelERPOutputModeEntry  

wtWebioEA12x6RelERPOutputModeBit 1.3.6.1.4.1.5040.1.2.26.3.1.4.1.1.1
This binary coded output mode defines the individual operation mode for any output. More than one mode must not be selected. The OCTETS are interpreted bit-by-bit, with each set of octets corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 6-7: unused Bit 5 : Logic Bit 4 : Binary 2 Bit 3 : Binary 1 Bit 2 : SNMP Bit 1 : UDP ASCII Bit 0 : HTTP
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelERPSafetyTimeout 1.3.6.1.4.1.5040.1.2.26.3.1.4.2
After this period of time (multiple of 100ms) without receiving data outputs switch to their Safety States. For each output a independend safety state could be defined.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA12x6RelERPAlarmCount 1.3.6.1.4.1.5040.1.2.26.3.1.5.1
Number of independent alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..12  

wtWebioEA12x6RelERPAlarmIfTable 1.3.6.1.4.1.5040.1.2.26.3.1.5.2
List of alarm indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA12x6RelERPAlarmIfEntry

wtWebioEA12x6RelERPAlarmIfEntry 1.3.6.1.4.1.5040.1.2.26.3.1.5.2.1
Numbers of the alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA12x6RelERPAlarmIfEntry  

wtWebioEA12x6RelERPAlarmNo 1.3.6.1.4.1.5040.1.2.26.3.1.5.2.1.1
Numbers of the alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..12  

wtWebioEA12x6RelERPAlarmTable 1.3.6.1.4.1.5040.1.2.26.3.1.5.3
List of settings depending on the alarm number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA12x6RelERPAlarmEntry

wtWebioEA12x6RelERPAlarmEntry 1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1
Alarm parameters of the individual alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA12x6RelERPAlarmEntry  

wtWebioEA12x6RelERPAlarmInputTrigger 1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.1
This variable allows setting of individual input trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the inputs are to be considered (corresponding bit = 1) and which inputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3, Bit 0-3: Mask for digital inputs 8-11 Bit 4-7: unused OCTET 4, Bit 0-7: Mask for digital inputs 0-7 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7, Bit 0-3: Level of digital inputs 8-11 Bit 4-7: unused OCTET 8, Bit 0-7: Level of digital inputs 0-7 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change of the corresponding input bit. Settings in OCTET 5-9 are then unused: OCTET 9 : unused OCTET 11, Bit 0-7 : ANY bits of digital inputs 8-11 Bit 12-15 : unused OCTET 12, Bit 0-7 : ANY bits of digital inputs 0-7
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(12)  

wtWebioEA12x6RelERPAlarmOutputTrigger 1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.2
This variable allows setting of individual output trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be considered (corresponding bit = 1) and which outputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-5: Mask for digital outputs 0-5 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-5: Level of digital outputs 0-5 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change of the corresponding output bit. Settings in OCTET 5-9 are then unused: OCTET 9 : unused OCTET 10: unused OCTET 11: unused OCTET 12: Bit 0-5: ANY bits of digital outputs 0-5
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(12)  

wtWebioEA12x6RelERPAlarmSystemTrigger 1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.3
Binary coded trigger conditions: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Warm Start Bit 2 : Cold Start Bit 1 : Timer Bit 0 : Load Control
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelERPAlarmMaxCounterValue 1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.4
This variable configures a max. counter value. If an input counter value exceeds this max. value, the corresponding alarm is triggered. Input counters with its mask bit unset in wtWebioEA12x6RelERPAlarmInputTrigger are not considered.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPAlarmInterval 1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.5
Send interval for alarm messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPAlarmEnable 1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.6
Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: UDP enable Bit 3: Send inputs to pending TCP connections Bit 4: TCP Client enable Bit 5: Syslog Messages enable Bit 6-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelERPAlarmMailAddr 1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.7
E-Mail address for sending the alarm mail to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPAlarmMailSubject 1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.8
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPAlarmMailText 1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.9
Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPAlarmSnmpManagerIP 1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.10
IP address of the SNMP Manager to which the Webio device should send SNMP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPAlarmSnmpTrapText 1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.11
This text appears in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPAlarmUdpIpAddr 1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.12
IP address of the UDP listener to which the Webio device should send UDP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPAlarmUdpPort 1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.13
Port number of the UDP listener to which the Webio device should send UDP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA12x6RelERPAlarmUdpText 1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.14
This text appears in the UDP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPAlarmTcpIpAddr 1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.15
IP address of the TCP listener to which the Webio device should send TCP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPAlarmTcpPort 1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.16
Port number of the TCP listener to which the Webio device should send TCP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA12x6RelERPAlarmTcpText 1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.17
This text appears in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPAlarmSyslogIpAddr 1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.18
IP address of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPAlarmSyslogPort 1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.19
Port number of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA12x6RelERPAlarmSyslogText 1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.20
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPAlarmFtpDataPort 1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.21
Local data port: 1..65535 or AUTO: the next free port will be assigned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPAlarmFtpFileName 1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.22
Name of the file including path informations.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPAlarmFtpText 1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.23
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPAlarmFtpOption 1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.24
Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelERPAlarmTimerCron 1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.25
This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPAlarmMailReleaseSubject 1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.26
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPAlarmMailReleaseText 1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.27
Release Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPAlarmSnmpTrapReleaseText 1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.28
This text appears in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPAlarmUdpReleaseText 1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.29
This text appears in the UDP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPAlarmTcpReleaseText 1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.30
This text appears in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPAlarmSyslogReleaseText 1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.31
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPAlarmFtpReleaseText 1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.32
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPInputPortTable 1.3.6.1.4.1.5040.1.2.26.3.2.1
List of settings depending on the input number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA12x6RelERPInputPortEntry

wtWebioEA12x6RelERPInputPortEntry 1.3.6.1.4.1.5040.1.2.26.3.2.1.1
Input parameter for the individual inputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA12x6RelERPInputPortEntry  

wtWebioEA12x6RelERPPortInputName 1.3.6.1.4.1.5040.1.2.26.3.2.1.1.1
Name of the input.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPPortInputText 1.3.6.1.4.1.5040.1.2.26.3.2.1.1.2
Description of the input.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPPortInputMode 1.3.6.1.4.1.5040.1.2.26.3.2.1.1.3
Binary coded modes: Selecting short pulse detection enable by setting the corresponding bit to 1 enables interrupt support for counting. Only positive edges are accepted as trigger source. The maximum counting frequenz equals 2000 Hz. This mode is available for inputs 0-3 only. Selecting counter clear on read by setting the corresponding bit to 1 enables the corresponding counter to be cleared automatically every time it is read, except HTTP reading with user rights. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. Selection for input 0-3: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 3-7: unused Bit 2 : Counter clear on read Bit 1 : Change detection enable (default) Bit 0 : Short Pulse detection enable Selection for inputs 4-11: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : Counter clear on read Bit 0 : Change detection enable (default)
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelERPPortInputFilter 1.3.6.1.4.1.5040.1.2.26.3.2.1.1.4
Pulses with a duration shorter than here specified (duration in 1/1000 sec), are ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelERPPortInputBicountPulsePolarity 1.3.6.1.4.1.5040.1.2.26.3.2.1.1.5
This value defines the polarity of the input pulse. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelERPPortInputBicountInactivTimeout 1.3.6.1.4.1.5040.1.2.26.3.2.1.1.6
Pulse chains with a duration shorter than here specified (in 1/10 sek), are ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelERPOutputPortTable 1.3.6.1.4.1.5040.1.2.26.3.2.2
List of settings depending on the output number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA12x6RelERPOutputPortEntry

wtWebioEA12x6RelERPOutputPortEntry 1.3.6.1.4.1.5040.1.2.26.3.2.2.1
Output parameters of the individual outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA12x6RelERPOutputPortEntry  

wtWebioEA12x6RelERPPortOutputName 1.3.6.1.4.1.5040.1.2.26.3.2.2.1.1
Name of the output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPPortOutputText 1.3.6.1.4.1.5040.1.2.26.3.2.2.1.2
Description of the output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPPortOutputGroupMode 1.3.6.1.4.1.5040.1.2.26.3.2.2.1.3
Unused in this device 57634
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPPortOutputSafetyState 1.3.6.1.4.1.5040.1.2.26.3.2.2.1.4
This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 1-7: unused Bit 0 : Mask for digital output OCTETS 5-8 contain the level (1=HIGH=Relais closed, 0=LOW Relais open) which the outputs to be changed should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 1-7: unused Bit 0 : Level of digital output
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPPortLogicInputMask 1.3.6.1.4.1.5040.1.2.26.3.2.2.1.5
Selecting one of these inputs by setting the corresponding bit to 1 enables the logic function for the output identified by the index within this table. The calculation take place in 4 steps: 1. Selecting inputs (wtWebioEA12x6RelERPPortLogicInputMask) 2. Inverting inputs if necessary (wtWebioEA12x6RelERPPortLogicInputInverter) 3. Logical combination (wtWebioEA12x6RelERPPortLogicFunction) 4. Inverting the result if necessary (wtWebioEA12x6RelERPPortLogicOutputInverter) OCTET 1: unused OCTET 2: unused OCTET 3: Bit 0-3 : inputs 8-11 Bit 4-7 : unused OCTET 4: Bit 0-7 : inputs 0-7
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelERPPortLogicInputInverter 1.3.6.1.4.1.5040.1.2.26.3.2.2.1.6
Every input bit selected here will be inverted. OCTET 1: unused OCTET 2: unused OCTET 3: Bit 0-3 : inputs 8-11 Bit 4-7 : unused OCTET 4: Bit 0-7 : inputs 0-7
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelERPPortLogicFunction 1.3.6.1.4.1.5040.1.2.26.3.2.2.1.7
This determines the logic function. No more than one function may be selected. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : logic function OR (default) Bit 1 : logic function AND Bit 2-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelERPPortLogicOutputInverter 1.3.6.1.4.1.5040.1.2.26.3.2.2.1.8
The logical operation result could be inverteted by setting the corresponding bit to 1. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : Output Inverter enable Bit 1-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelERPPortPulseDuration 1.3.6.1.4.1.5040.1.2.26.3.2.2.1.9
Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelERPPortPulsePolarity 1.3.6.1.4.1.5040.1.2.26.3.2.2.1.10
This value defines the polarity of the output pulse, if wtWebioEA12x6RelERPPortPulseDuration is not set to zero. After the pulse is finished, the output switches back to the opposite state. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA12x6RelERPMfName 1.3.6.1.4.1.5040.1.2.26.3.3.1
Manufacturer company name
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPMfAddr 1.3.6.1.4.1.5040.1.2.26.3.3.2
Manufacturer address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPMfHotline 1.3.6.1.4.1.5040.1.2.26.3.3.3
Manufacturer hotline.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPMfInternet 1.3.6.1.4.1.5040.1.2.26.3.3.4
Manufacturer Internet address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPMfDeviceTyp 1.3.6.1.4.1.5040.1.2.26.3.3.5
Manufacturer device name (model number).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPMfOrderNo 1.3.6.1.4.1.5040.1.2.26.3.3.6
Manufacturer part number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPDiagErrorCount 1.3.6.1.4.1.5040.1.2.26.4.1
Number of entries in the error memory.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelERPDiagBinaryError 1.3.6.1.4.1.5040.1.2.26.4.2
Error causes coded bit-by-bit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPDiagErrorIndex 1.3.6.1.4.1.5040.1.2.26.4.3
The value of this variable is used as an index to read an error massege from wtWebioEA12x6RelERPDiagErrorMessage. Errors are numbered from 1 to wtWebioEA12x6RelERPDiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebioEA12x6RelERPDiagErrorMessage.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelERPDiagErrorMessage 1.3.6.1.4.1.5040.1.2.26.4.4
Using wtWebioEA12x6RelERPDiagErrorIndex as an index, the appropriate message is available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA12x6RelERPDiagErrorClear 1.3.6.1.4.1.5040.1.2.26.4.5
Writing 1 into this variable clears all diagnosis messages.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA12x6RelERPAlert1 41
This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelERPAlert2 42
This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelERPAlert3 43
This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelERPAlert4 44
This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelERPAlert5 45
This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelERPAlert6 46
This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelERPAlert7 47
This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelERPAlert8 48
This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelERPAlert9 49
This SNMP trap is generated when Alarm 9 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelERPAlert10 50
This SNMP trap is generated when Alarm 10 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelERPAlert11 51
This SNMP trap is generated when Alarm 11 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelERPAlert12 52
This SNMP trap is generated when Alarm 12 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelERPAlert13 71
This SNMP trap is generated when Alarm 1 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelERPAlert14 72
This SNMP trap is generated when Alarm 2 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelERPAlert15 73
This SNMP trap is generated when Alarm 3 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelERPAlert16 74
This SNMP trap is generated when Alarm 4 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelERPAlert17 75
This SNMP trap is generated when Alarm 5 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelERPAlert18 76
This SNMP trap is generated when Alarm 6 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelERPAlert19 77
This SNMP trap is generated when Alarm 7 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelERPAlert20 78
This SNMP trap is generated when Alarm 8 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelERPAlert21 79
This SNMP trap is generated when Alarm 9 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelERPAlert22 80
This SNMP trap is generated when Alarm 10 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelERPAlert23 81
This SNMP trap is generated when Alarm 11 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelERPAlert24 82
This SNMP trap is generated when Alarm 12 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA12x6RelERPAlertDiag 110
This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherInputs 1.3.6.1.4.1.5040.1.2.27.1.1
Number of idependent inputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtIpWatcherOutputs 1.3.6.1.4.1.5040.1.2.27.1.2
Number of idependent outputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtIpWatcherInputTable 1.3.6.1.4.1.5040.1.2.27.1.3
List of input indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtIpWatcherInputEntry

wtIpWatcherInputEntry 1.3.6.1.4.1.5040.1.2.27.1.3.1
Number of the inputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtIpWatcherInputEntry  

wtIpWatcherInputNo 1.3.6.1.4.1.5040.1.2.27.1.3.1.1
Index numbers of the inputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtIpWatcherInputCounter 1.3.6.1.4.1.5040.1.2.27.1.3.1.2
Value of the input counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtIpWatcherInputCounterClear 1.3.6.1.4.1.5040.1.2.27.1.3.1.3
Clears the input counter after returning its value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtIpWatcherInputState 1.3.6.1.4.1.5040.1.2.27.1.3.1.4
Value of a single input bit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtIpWatcherInputState-OFF(0), wtIpWatcherInputState-ON(1)  

wtIpWatcherInputValue 1.3.6.1.4.1.5040.1.2.27.1.4
This variable is used to read the inputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital outputs 0-1
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtIpWatcherOutputTable 1.3.6.1.4.1.5040.1.2.27.1.5
List of output indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtIpWatcherOutputEntry

wtIpWatcherOutputEntry 1.3.6.1.4.1.5040.1.2.27.1.5.1
Number of the outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtIpWatcherOutputEntry  

wtIpWatcherOutputNo 1.3.6.1.4.1.5040.1.2.27.1.5.1.1
Output number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtIpWatcherOutputState 1.3.6.1.4.1.5040.1.2.27.1.5.1.2
Value of a single output bit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtIpWatcherOutputState-OFF(0), wtIpWatcherOutputState-ON(1)  

wtIpWatcherOutputValue 1.3.6.1.4.1.5040.1.2.27.1.6
This variable is used to read and write the outputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital outputs 0-1 Bit 2-7: ungenutzt
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcherSetOutput 1.3.6.1.4.1.5040.1.2.27.1.7
This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first two OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital outputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital outputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

wtIpWatcherAlarmOutputTable 1.3.6.1.4.1.5040.1.2.27.1.8
List of alarm indices..
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtIpWatcherAlarmOutputEntry

wtIpWatcherAlarmOutputEntry 1.3.6.1.4.1.5040.1.2.27.1.8.1
Index reference.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtIpWatcherAlarmOutputEntry  

wtIpWatcherAlarmOutputState 1.3.6.1.4.1.5040.1.2.27.1.8.1.1
State of the alarm.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtIpWatcherAlarmOutputState-OFF(0), wtIpWatcherAlarmOutputState-ON(1)  

wtIpWatcherAlarmTriggerState 1.3.6.1.4.1.5040.1.2.27.1.8.1.2
State of the trigger condition.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtIpWatcherAlarmTriggerState-OFF(0), wtIpWatcherAlarmTriggerState-ON(1)  

wtIpWatcherSessCntrlPassword 1.3.6.1.4.1.5040.1.2.27.2.1
Entering this password opens a session which is ended by writing a 1 to wtIpWatcherSessCntrlLogout. When read this variable provides a string of length zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherSessCntrlConfigMode 1.3.6.1.4.1.5040.1.2.27.2.2
When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtIpWatcherSessCntrl-NoSession(0), wtIpWatcherSessCntrl-Session(1)  

wtIpWatcherSessCntrlLogout 1.3.6.1.4.1.5040.1.2.27.2.3
If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcherSessCntrlAdminPassword 1.3.6.1.4.1.5040.1.2.27.2.4
This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherSessCntrlConfigPassword 1.3.6.1.4.1.5040.1.2.27.2.5
This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherDeviceName 1.3.6.1.4.1.5040.1.2.27.3.1.1.1
Name of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherDeviceText 1.3.6.1.4.1.5040.1.2.27.3.1.1.2
Description of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherDeviceLocation 1.3.6.1.4.1.5040.1.2.27.3.1.1.3
Description of the location of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherDeviceContact 1.3.6.1.4.1.5040.1.2.27.3.1.1.4
Contact address of the system operator of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherTzOffsetHrs 1.3.6.1.4.1.5040.1.2.27.3.1.2.1.1
Offset hours for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcherTzOffsetMin 1.3.6.1.4.1.5040.1.2.27.3.1.2.1.2
Offset minutes for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcherTzEnable 1.3.6.1.4.1.5040.1.2.27.3.1.2.1.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtIpWatcherStTzOffsetHrs 1.3.6.1.4.1.5040.1.2.27.3.1.2.1.4
Offset hours of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcherStTzOffsetMin 1.3.6.1.4.1.5040.1.2.27.3.1.2.1.5
Offset minutes of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcherStTzEnable 1.3.6.1.4.1.5040.1.2.27.3.1.2.1.6
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtIpWatcherStTzStartMonth 1.3.6.1.4.1.5040.1.2.27.3.1.2.1.7
Month in which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtIpWatcherStartMonth-January(1), wtIpWatcherStartMonth-February(2), wtIpWatcherStartMonth-March(3), wtIpWatcherStartMonth-April(4), wtIpWatcherStartMonth-May(5), wtIpWatcherStartMonth-June(6), wtIpWatcherStartMonth-July(7), wtIpWatcherStartMonth-August(8), wtIpWatcherStartMonth-September(9), wtIpWatcherStartMonth-October(10), wtIpWatcherStartMonth-November(11), wtIpWatcherStartMonth-December(12)  

wtIpWatcherStTzStartMode 1.3.6.1.4.1.5040.1.2.27.3.1.2.1.8
Mode of the day of the week for which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtIpWatcherStartMode-first(1), wtIpWatcherStartMode-second(2), wtIpWatcherStartMode-third(3), wtIpWatcherStartMode-fourth(4), wtIpWatcherStartMode-last(5)  

wtIpWatcherStTzStartWday 1.3.6.1.4.1.5040.1.2.27.3.1.2.1.9
Day of the week on which the change is made from winter time to summer time
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtIpWatcherStartWday-Sunday(1), wtIpWatcherStartWday-Monday(2), wtIpWatcherStartWday-Tuesday(3), wtIpWatcherStartWday-Thursday(4), wtIpWatcherStartWday-Wednesday(5), wtIpWatcherStartWday-Friday(6), wtIpWatcherStartWday-Saturday(7)  

wtIpWatcherStTzStartHrs 1.3.6.1.4.1.5040.1.2.27.3.1.2.1.10
Hour in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcherStTzStartMin 1.3.6.1.4.1.5040.1.2.27.3.1.2.1.11
Minute in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcherStTzStopMonth 1.3.6.1.4.1.5040.1.2.27.3.1.2.1.12
Month in which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtIpWatcherStopMonth-January(1), wtIpWatcherStopMonth-February(2), wtIpWatcherStopMonth-March(3), wtIpWatcherStopMonth-April(4), wtIpWatcherStopMonth-May(5), wtIpWatcherStopMonth-June(6), wtIpWatcherStopMonth-July(7), wtIpWatcherStopMonth-August(8), wtIpWatcherStopMonth-September(9), wtIpWatcherStopMonth-October(10), wtIpWatcherStopMonth-November(11), wtIpWatcherStopMonth-December(12)  

wtIpWatcherStTzStopMode 1.3.6.1.4.1.5040.1.2.27.3.1.2.1.13
Mode of the week day on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtIpWatcherStopMode-first(1), wtIpWatcherStopMode-second(2), wtIpWatcherStopMode-third(3), wtIpWatcherStopMode-fourth(4), wtIpWatcherStopMode-last(5)  

wtIpWatcherStTzStopWday 1.3.6.1.4.1.5040.1.2.27.3.1.2.1.14
Day of the week on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtIpWatcherStopWday-Sunday(1), wtIpWatcherStopWday-Monday(2), wtIpWatcherStopWday-Tuesday(3), wtIpWatcherStopWday-Thursday(4), wtIpWatcherStopWday-Wednesday(5), wtIpWatcherStopWday-Friday(6), wtIpWatcherStopWday-Saturday(7)  

wtIpWatcherStTzStopHrs 1.3.6.1.4.1.5040.1.2.27.3.1.2.1.15
Hour at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcherStTzStopMin 1.3.6.1.4.1.5040.1.2.27.3.1.2.1.16
Minute at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcherTimeServer1 1.3.6.1.4.1.5040.1.2.27.3.1.2.2.1
IP address or name of the 1st time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherTimeServer2 1.3.6.1.4.1.5040.1.2.27.3.1.2.2.2
IP address or name of the 2nd time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherTsEnable 1.3.6.1.4.1.5040.1.2.27.3.1.2.2.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtIpWatcherTsSyncTime 1.3.6.1.4.1.5040.1.2.27.3.1.2.2.4
Daily synchronisation time with the time server (hour: 0-23).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcherClockHrs 1.3.6.1.4.1.5040.1.2.27.3.1.2.3.1
Clock hours taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..23  

wtIpWatcherClockMin 1.3.6.1.4.1.5040.1.2.27.3.1.2.3.2
Clock minutes taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..59  

wtIpWatcherClockDay 1.3.6.1.4.1.5040.1.2.27.3.1.2.3.3
Date: Day of the month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..31  

wtIpWatcherClockMonth 1.3.6.1.4.1.5040.1.2.27.3.1.2.3.4
Date: Month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtIpWatcherClockMonth-January(1), wtIpWatcherClockMonth-February(2), wtIpWatcherClockMonth-March(3), wtIpWatcherClockMonth-April(4), wtIpWatcherClockMonth-May(5), wtIpWatcherClockMonth-June(6), wtIpWatcherClockMonth-July(7), wtIpWatcherClockMonth-August(8), wtIpWatcherClockMonth-September(9), wtIpWatcherClockMonth-October(10), wtIpWatcherClockMonth-November(11), wtIpWatcherClockMonth-December(12)  

wtIpWatcherClockYear 1.3.6.1.4.1.5040.1.2.27.3.1.2.3.5
Date: Year, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtIpWatcherIpAddress 1.3.6.1.4.1.5040.1.2.27.3.1.3.1.1
IP address of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtIpWatcherSubnetMask 1.3.6.1.4.1.5040.1.2.27.3.1.3.1.2
Subnet mask of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtIpWatcherGateway 1.3.6.1.4.1.5040.1.2.27.3.1.3.1.3
Gateway of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtIpWatcherDnsServer1 1.3.6.1.4.1.5040.1.2.27.3.1.3.1.4
IP address of the 1st DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherDnsServer2 1.3.6.1.4.1.5040.1.2.27.3.1.3.1.5
IP address of the 2nd DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAddConfig 1.3.6.1.4.1.5040.1.2.27.3.1.3.1.6
Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP enable Bit 0: BOOTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherHttpPort 1.3.6.1.4.1.5040.1.2.27.3.1.3.2.4
Definition of the standard HTML port (Default: 80).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65534  

wtIpWatcherMailAdName 1.3.6.1.4.1.5040.1.2.27.3.1.3.3.1
Device name for mail administration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherMailReply 1.3.6.1.4.1.5040.1.2.27.3.1.3.3.2
Reply address for the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherMailServer 1.3.6.1.4.1.5040.1.2.27.3.1.3.3.3
Name or IP address of the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherMailEnable 1.3.6.1.4.1.5040.1.2.27.3.1.3.3.4
Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherMailAuthentication 1.3.6.1.4.1.5040.1.2.27.3.1.3.3.5
Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtIpWatcherMailAuthUser 1.3.6.1.4.1.5040.1.2.27.3.1.3.3.6
Name of the user to be authenticated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherMailAuthPassword 1.3.6.1.4.1.5040.1.2.27.3.1.3.3.7
Authentication password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherMailPop3Server 1.3.6.1.4.1.5040.1.2.27.3.1.3.3.8
Name or Ip-address of the POP3 Servers.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherSnmpEnable 1.3.6.1.4.1.5040.1.2.27.3.1.3.4.1
Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherSnmpCommunityStringRead 1.3.6.1.4.1.5040.1.2.27.3.1.3.4.2
Community string read only
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherSnmpCommunityStringReadWrite 1.3.6.1.4.1.5040.1.2.27.3.1.3.4.3
Community string read / write
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherSnmpSystemTrapManagerIP 1.3.6.1.4.1.5040.1.2.27.3.1.3.4.4
Name or IP address of the TCP server which accepts the system trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherSnmpSystemTrapEnable 1.3.6.1.4.1.5040.1.2.27.3.1.3.4.5
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag messages Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtIpWatcherUdpAdminPort 1.3.6.1.4.1.5040.1.2.27.3.1.3.5.1
Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcherUdpEnable 1.3.6.1.4.1.5040.1.2.27.3.1.3.5.2
Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherUdpRemotePort 1.3.6.1.4.1.5040.1.2.27.3.1.3.5.3
Udp remote port setting. If this value is set to zero, the source port read from a request will be used as destination port for the answer. A non zero value forced the destination port to this value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcherSyslogServerIP 1.3.6.1.4.1.5040.1.2.27.3.1.3.7.1
Name or IP address of the Syslog server, which accepts the Syslog messgaes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherSyslogServerPort 1.3.6.1.4.1.5040.1.2.27.3.1.3.7.2
Portnumber of the Syslog servers, default 514.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcherSyslogSystemMessagesEnable 1.3.6.1.4.1.5040.1.2.27.3.1.3.7.3
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtIpWatcherSyslogEnable 1.3.6.1.4.1.5040.1.2.27.3.1.3.7.4
Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherFTPServerIP 1.3.6.1.4.1.5040.1.2.27.3.1.3.8.1
Name or IP address of the FTP server, which accepts the FTP messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherFTPServerControlPort 1.3.6.1.4.1.5040.1.2.27.3.1.3.8.2
Portnumber of the control port of the FTP server, default 21.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcherFTPUserName 1.3.6.1.4.1.5040.1.2.27.3.1.3.8.3
FTP Loggin: user name.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherFTPPassword 1.3.6.1.4.1.5040.1.2.27.3.1.3.8.4
FTP Loggin: user password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherFTPAccount 1.3.6.1.4.1.5040.1.2.27.3.1.3.8.5
FTP Loggin: name of account.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherFTPOption 1.3.6.1.4.1.5040.1.2.27.3.1.3.8.6
Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherFTPEnable 1.3.6.1.4.1.5040.1.2.27.3.1.3.8.7
Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherIpListCount 1.3.6.1.4.1.5040.1.2.27.3.1.3.11.1
Number of Ip addresses.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtIpWatcherIpListIfTable 1.3.6.1.4.1.5040.1.2.27.3.1.3.11.2
Table of inices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtIpWatcherIpListIfEntry

wtIpWatcherIpListIfEntry 1.3.6.1.4.1.5040.1.2.27.3.1.3.11.2.1
Table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtIpWatcherIpListIfEntry  

wtIpWatcherIpListNo 1.3.6.1.4.1.5040.1.2.27.3.1.3.11.2.1.1
List number of this entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..999  

wtIpWatcherIpListTable 1.3.6.1.4.1.5040.1.2.27.3.1.3.11.3
List of ip addresses.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtIpWatcherIpListEntry

wtIpWatcherIpListEntry 1.3.6.1.4.1.5040.1.2.27.3.1.3.11.3.1
List entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtIpWatcherIpListEntry  

wtIpWatcherIpListName 1.3.6.1.4.1.5040.1.2.27.3.1.3.11.3.1.1
Name or IP address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherIpListPort 1.3.6.1.4.1.5040.1.2.27.3.1.3.11.3.1.2
Port number, zero in the case of broadcast or Ping.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcherIpListService 1.3.6.1.4.1.5040.1.2.27.3.1.3.11.3.1.3
Binary coded scan mode, only one mode can be selected at a particular time: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Ping enable Bit 1-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherIpListEnable 1.3.6.1.4.1.5040.1.2.27.3.1.3.11.3.1.4
Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: enabled in Alarm 1 Bit 1: enabled in Alarm 2 Bit 2: enabled in Alarm 3 Bit 3: enabled in Alarm 4 Bit 4-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherIpListAlias 1.3.6.1.4.1.5040.1.2.27.3.1.3.11.3.1.5
Alias Name
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmCount 1.3.6.1.4.1.5040.1.2.27.3.1.5.1
Number of independent alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

wtIpWatcherAlarmIfTable 1.3.6.1.4.1.5040.1.2.27.3.1.5.2
List of alarm indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtIpWatcherAlarmIfEntry

wtIpWatcherAlarmIfEntry 1.3.6.1.4.1.5040.1.2.27.3.1.5.2.1
Numbers of the alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtIpWatcherAlarmIfEntry  

wtIpWatcherAlarmNo 1.3.6.1.4.1.5040.1.2.27.3.1.5.2.1.1
Numbers of the alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

wtIpWatcherAlarmTable 1.3.6.1.4.1.5040.1.2.27.3.1.5.3
List of settings depending on the alarm number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtIpWatcherAlarmEntry

wtIpWatcherAlarmEntry 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1
Alarm parameters of the individual alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtIpWatcherAlarmEntry  

wtIpWatcherAlarmInterval 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.5
Send interval for alarm messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmEnable 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.6
Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: UDP enable Bit 3: Send inputs to pending TCP connections Bit 4: TCP Client enable Bit 5: Syslog Messages enable Bit 6-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtIpWatcherAlarmMailAddr 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.7
E-Mail address for sending the alarm mail to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmMailSubject 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.8
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmMailText 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.9
Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmSnmpManagerIP 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.10
IP address of the SNMP Manager to which the Webio device should send SNMP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmSnmpTrapText 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.11
This text appears in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmUdpIpAddr 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.12
IP address of the UDP listener to which the Webio device should send UDP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmUdpPort 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.13
Port number of the UDP listener to which the Webio device should send UDP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtIpWatcherAlarmUdpText 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.14
This text appears in the UDP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmTcpIpAddr 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.15
IP address of the TCP listener to which the Webio device should send TCP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmTcpPort 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.16
Port number of the TCP listener to which the Webio device should send TCP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtIpWatcherAlarmTcpText 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.17
This text appears in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmSyslogIpAddr 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.18
IP address of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmSyslogPort 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.19
Port number of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtIpWatcherAlarmSyslogText 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.20
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmFtpDataPort 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.21
Local data port: 1..65535 or AUTO: the next free port will be assigned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmFtpFileName 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.22
Name of the file including path informations.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmFtpText 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.23
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmFtpOption 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.24
Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtIpWatcherAlarmTimerCron 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.25
This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmMailReleaseSubject 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.26
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmMailReleaseText 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.27
Release Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmSnmpTrapReleaseText 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.28
This text appears in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmUdpReleaseText 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.29
This text appears in the UDP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmTcpReleaseText 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.30
This text appears in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmSyslogReleaseText 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.31
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmFtpReleaseText 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.32
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmName 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.33
Name of the alarm.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmGlobalEnable 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.34
Binary coded alarm activation: Die OCTETS werden bitweise interpretiert. Bit 0 entspricht dem LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : Alarm enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmCounterClear 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.35
Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : Counter clear on Alarm acknowledge Bit 0 : Counter clear on Alarm send
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmAckEnable 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.36
Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : Software acknowledge enable Bit 0 : Hardware acknowledge enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmAckPort 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.37
Number of the input, which clears the alarm (1-6).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcherAlarmSetPort 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.38
Number of the output, which will be set by this alarm (1-6). The configuration of pulse mode and polarity defined in the port output section is used.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcherAlarmMailTrgClearSubject 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.39
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmMailTrgClearText 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.40
Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmSnmpTrapTrgClearText 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.41
This text appears in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmUdpTrgClearText 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.42
This text appears in the UDP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmTcpTrgClearText 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.43
This text appears in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmSyslogTrgClearText 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.44
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmFtpTrgClearText 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.45
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmMailTrapTxEnable 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.46
Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmSnmpTrapTrapTxEnable 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.47
Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmUdpTrapTxEnable 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.48
Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmTcpTrapTxEnable 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.49
Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmSyslogTrapTxEnable 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.50
Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmFtpTrapTxEnable 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.51
Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherAlarmTriggerCount 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.52
Alarm will be send if the trigger condition occours TriggerCount times.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcherAlarmPollingRate 1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.53
Time in seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcherInputPortTable 1.3.6.1.4.1.5040.1.2.27.3.2.1
List of settings depending on the input number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtIpWatcherInputPortEntry

wtIpWatcherInputPortEntry 1.3.6.1.4.1.5040.1.2.27.3.2.1.1
Input parameter for the individual inputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtIpWatcherInputPortEntry  

wtIpWatcherPortInputName 1.3.6.1.4.1.5040.1.2.27.3.2.1.1.1
Name of the input.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherPortInputText 1.3.6.1.4.1.5040.1.2.27.3.2.1.1.2
Description of the input.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherPortInputFilter 1.3.6.1.4.1.5040.1.2.27.3.2.1.1.4
Pulses with a duration shorter than here specified (duration in 1/1000 sec), are ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcherOutputPortTable 1.3.6.1.4.1.5040.1.2.27.3.2.2
List of settings depending on the output number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtIpWatcherOutputPortEntry

wtIpWatcherOutputPortEntry 1.3.6.1.4.1.5040.1.2.27.3.2.2.1
Output parameters of the individual outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtIpWatcherOutputPortEntry  

wtIpWatcherPortOutputName 1.3.6.1.4.1.5040.1.2.27.3.2.2.1.1
Name of the output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherPortOutputText 1.3.6.1.4.1.5040.1.2.27.3.2.2.1.2
Description of the output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherPortPulseDuration 1.3.6.1.4.1.5040.1.2.27.3.2.2.1.9
Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcherPortPulsePolarity 1.3.6.1.4.1.5040.1.2.27.3.2.2.1.10
This value defines the polarity of the output pulse, if wtIpWatcherPortPulseDuration is not set to zero. After the pulse is finished, the output switches back to the opposite state. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtIpWatcherMfName 1.3.6.1.4.1.5040.1.2.27.3.3.1
Manufacturer company name
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherMfAddr 1.3.6.1.4.1.5040.1.2.27.3.3.2
Manufacturer address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherMfHotline 1.3.6.1.4.1.5040.1.2.27.3.3.3
Manufacturer hotline.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherMfInternet 1.3.6.1.4.1.5040.1.2.27.3.3.4
Manufacturer Internet address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherMfDeviceTyp 1.3.6.1.4.1.5040.1.2.27.3.3.5
Manufacturer device name (model number).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherDiagErrorCount 1.3.6.1.4.1.5040.1.2.27.4.1
Number of entries in the error memory.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtIpWatcherDiagBinaryError 1.3.6.1.4.1.5040.1.2.27.4.2
Error causes coded bit-by-bit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherDiagErrorIndex 1.3.6.1.4.1.5040.1.2.27.4.3
The value of this variable is used as an index to read an error massege from wtIpWatcherDiagErrorMessage. Errors are numbered from 1 to wtIpWatcherDiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtIpWatcherDiagErrorMessage.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcherDiagErrorMessage 1.3.6.1.4.1.5040.1.2.27.4.4
Using wtIpWatcherDiagErrorIndex as an index, the appropriate message is available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcherDiagErrorClear 1.3.6.1.4.1.5040.1.2.27.4.5
Writing 1 into this variable clears all diagnosis messages.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER  

wtIpWatcherAlert1 41
This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert2 42
This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert3 43
This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert4 44
This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert5 45
This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert6 46
This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert7 47
This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert8 48
This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert9 49
This SNMP trap is generated when Alarm 9 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert10 50
This SNMP trap is generated when Alarm 10 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert11 51
This SNMP trap is generated when Alarm 11 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert12 52
This SNMP trap is generated when Alarm 12 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert13 71
This SNMP trap is generated when Alarm 1 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert14 72
This SNMP trap is generated when Alarm 2 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert15 73
This SNMP trap is generated when Alarm 3 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert16 74
This SNMP trap is generated when Alarm 4 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert17 75
This SNMP trap is generated when Alarm 5 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert18 76
This SNMP trap is generated when Alarm 6 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert19 77
This SNMP trap is generated when Alarm 7 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert20 78
This SNMP trap is generated when Alarm 8 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert21 79
This SNMP trap is generated when Alarm 9 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert22 80
This SNMP trap is generated when Alarm 10 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert23 81
This SNMP trap is generated when Alarm 11 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert24 82
This SNMP trap is generated when Alarm 12 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert25 91
This SNMP trap is generated when the trigger of the Alarm 1 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert26 92
This SNMP trap is generated when the trigger of the Alarm 2 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert27 93
This SNMP trap is generated when the trigger of the Alarm 3 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert28 94
This SNMP trap is generated when the trigger of the Alarm 4 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert29 95
This SNMP trap is generated when the trigger of the Alarm 5 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert30 96
This SNMP trap is generated when the trigger of the Alarm 6 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert31 97
This SNMP trap is generated when the trigger of the Alarm 7 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert32 98
This SNMP trap is generated when the trigger of the Alarm 8 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert33 99
This SNMP trap is generated when the trigger of the Alarm 9 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert34 100
This SNMP trap is generated when the trigger of the Alarm 10 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert35 101
This SNMP trap is generated when the trigger of the Alarm 11 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlert36 102
This SNMP trap is generated when the trigger of the Alarm 12 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcherAlertDiag 110
This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2-24VInputs 1.3.6.1.4.1.5040.1.2.30.1.1
Number of idependent inputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtWebioEA2x2-24VOutputs 1.3.6.1.4.1.5040.1.2.30.1.2
Number of idependent outputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtWebioEA2x2-24VInputTable 1.3.6.1.4.1.5040.1.2.30.1.3
List of input indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2-24VInputEntry

wtWebioEA2x2-24VInputEntry 1.3.6.1.4.1.5040.1.2.30.1.3.1
Number of the inputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2-24VInputEntry  

wtWebioEA2x2-24VInputNo 1.3.6.1.4.1.5040.1.2.30.1.3.1.1
Index numbers of the inputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebioEA2x2-24VInputCounter 1.3.6.1.4.1.5040.1.2.30.1.3.1.2
Value of the input counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebioEA2x2-24VInputCounterClear 1.3.6.1.4.1.5040.1.2.30.1.3.1.3
Clears the input counter after returning its value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2-24VInputState 1.3.6.1.4.1.5040.1.2.30.1.3.1.4
Value of a single input bit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtWebioEA2x2-24VInputState-OFF(0), wtWebioEA2x2-24VInputState-ON(1)  

wtWebioEA2x2-24VInputValue 1.3.6.1.4.1.5040.1.2.30.1.4
This variable is used to read the inputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital outputs 0-1
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2-24VOutputTable 1.3.6.1.4.1.5040.1.2.30.1.5
List of output indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2-24VOutputEntry

wtWebioEA2x2-24VOutputEntry 1.3.6.1.4.1.5040.1.2.30.1.5.1
Number of the outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2-24VOutputEntry  

wtWebioEA2x2-24VOutputNo 1.3.6.1.4.1.5040.1.2.30.1.5.1.1
Output number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebioEA2x2-24VOutputState 1.3.6.1.4.1.5040.1.2.30.1.5.1.2
Value of a single output bit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA2x2-24VOutputState-OFF(0), wtWebioEA2x2-24VOutputState-ON(1)  

wtWebioEA2x2-24VOutputValue 1.3.6.1.4.1.5040.1.2.30.1.6
This variable is used to read and write the outputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital outputs 0-1 Bit 2-7: ungenutzt
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2-24VSetOutput 1.3.6.1.4.1.5040.1.2.30.1.7
This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first two OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital outputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital outputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

wtWebioEA2x2-24VSessCntrlPassword 1.3.6.1.4.1.5040.1.2.30.2.1
Entering this password opens a session which is ended by writing a 1 to wtWebioEA2x2-24VSessCntrlLogout. When read this variable provides a string of length zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VSessCntrlConfigMode 1.3.6.1.4.1.5040.1.2.30.2.2
When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtWebioEA2x2-24VSessCntrl-NoSession(0), wtWebioEA2x2-24VSessCntrl-Session(1)  

wtWebioEA2x2-24VSessCntrlLogout 1.3.6.1.4.1.5040.1.2.30.2.3
If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2-24VSessCntrlAdminPassword 1.3.6.1.4.1.5040.1.2.30.2.4
This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VSessCntrlConfigPassword 1.3.6.1.4.1.5040.1.2.30.2.5
This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VDeviceName 1.3.6.1.4.1.5040.1.2.30.3.1.1.1
Name of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VDeviceText 1.3.6.1.4.1.5040.1.2.30.3.1.1.2
Description of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VDeviceLocation 1.3.6.1.4.1.5040.1.2.30.3.1.1.3
Description of the location of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VDeviceContact 1.3.6.1.4.1.5040.1.2.30.3.1.1.4
Contact address of the system operator of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VTzOffsetHrs 1.3.6.1.4.1.5040.1.2.30.3.1.2.1.1
Offset hours for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2-24VTzOffsetMin 1.3.6.1.4.1.5040.1.2.30.3.1.2.1.2
Offset minutes for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2-24VTzEnable 1.3.6.1.4.1.5040.1.2.30.3.1.2.1.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2-24VStTzOffsetHrs 1.3.6.1.4.1.5040.1.2.30.3.1.2.1.4
Offset hours of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2-24VStTzOffsetMin 1.3.6.1.4.1.5040.1.2.30.3.1.2.1.5
Offset minutes of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2-24VStTzEnable 1.3.6.1.4.1.5040.1.2.30.3.1.2.1.6
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2-24VStTzStartMonth 1.3.6.1.4.1.5040.1.2.30.3.1.2.1.7
Month in which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA2x2-24VStartMonth-January(1), wtWebioEA2x2-24VStartMonth-February(2), wtWebioEA2x2-24VStartMonth-March(3), wtWebioEA2x2-24VStartMonth-April(4), wtWebioEA2x2-24VStartMonth-May(5), wtWebioEA2x2-24VStartMonth-June(6), wtWebioEA2x2-24VStartMonth-July(7), wtWebioEA2x2-24VStartMonth-August(8), wtWebioEA2x2-24VStartMonth-September(9), wtWebioEA2x2-24VStartMonth-October(10), wtWebioEA2x2-24VStartMonth-November(11), wtWebioEA2x2-24VStartMonth-December(12)  

wtWebioEA2x2-24VStTzStartMode 1.3.6.1.4.1.5040.1.2.30.3.1.2.1.8
Mode of the day of the week for which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA2x2-24VStartMode-first(1), wtWebioEA2x2-24VStartMode-second(2), wtWebioEA2x2-24VStartMode-third(3), wtWebioEA2x2-24VStartMode-fourth(4), wtWebioEA2x2-24VStartMode-last(5)  

wtWebioEA2x2-24VStTzStartWday 1.3.6.1.4.1.5040.1.2.30.3.1.2.1.9
Day of the week on which the change is made from winter time to summer time
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA2x2-24VStartWday-Sunday(1), wtWebioEA2x2-24VStartWday-Monday(2), wtWebioEA2x2-24VStartWday-Tuesday(3), wtWebioEA2x2-24VStartWday-Thursday(4), wtWebioEA2x2-24VStartWday-Wednesday(5), wtWebioEA2x2-24VStartWday-Friday(6), wtWebioEA2x2-24VStartWday-Saturday(7)  

wtWebioEA2x2-24VStTzStartHrs 1.3.6.1.4.1.5040.1.2.30.3.1.2.1.10
Hour in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2-24VStTzStartMin 1.3.6.1.4.1.5040.1.2.30.3.1.2.1.11
Minute in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2-24VStTzStopMonth 1.3.6.1.4.1.5040.1.2.30.3.1.2.1.12
Month in which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA2x2-24VStopMonth-January(1), wtWebioEA2x2-24VStopMonth-February(2), wtWebioEA2x2-24VStopMonth-March(3), wtWebioEA2x2-24VStopMonth-April(4), wtWebioEA2x2-24VStopMonth-May(5), wtWebioEA2x2-24VStopMonth-June(6), wtWebioEA2x2-24VStopMonth-July(7), wtWebioEA2x2-24VStopMonth-August(8), wtWebioEA2x2-24VStopMonth-September(9), wtWebioEA2x2-24VStopMonth-October(10), wtWebioEA2x2-24VStopMonth-November(11), wtWebioEA2x2-24VStopMonth-December(12)  

wtWebioEA2x2-24VStTzStopMode 1.3.6.1.4.1.5040.1.2.30.3.1.2.1.13
Mode of the week day on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA2x2-24VStopMode-first(1), wtWebioEA2x2-24VStopMode-second(2), wtWebioEA2x2-24VStopMode-third(3), wtWebioEA2x2-24VStopMode-fourth(4), wtWebioEA2x2-24VStopMode-last(5)  

wtWebioEA2x2-24VStTzStopWday 1.3.6.1.4.1.5040.1.2.30.3.1.2.1.14
Day of the week on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA2x2-24VStopWday-Sunday(1), wtWebioEA2x2-24VStopWday-Monday(2), wtWebioEA2x2-24VStopWday-Tuesday(3), wtWebioEA2x2-24VStopWday-Thursday(4), wtWebioEA2x2-24VStopWday-Wednesday(5), wtWebioEA2x2-24VStopWday-Friday(6), wtWebioEA2x2-24VStopWday-Saturday(7)  

wtWebioEA2x2-24VStTzStopHrs 1.3.6.1.4.1.5040.1.2.30.3.1.2.1.15
Hour at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2-24VStTzStopMin 1.3.6.1.4.1.5040.1.2.30.3.1.2.1.16
Minute at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2-24VTimeServer1 1.3.6.1.4.1.5040.1.2.30.3.1.2.2.1
IP address or name of the 1st time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VTimeServer2 1.3.6.1.4.1.5040.1.2.30.3.1.2.2.2
IP address or name of the 2nd time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VTsEnable 1.3.6.1.4.1.5040.1.2.30.3.1.2.2.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2-24VTsSyncTime 1.3.6.1.4.1.5040.1.2.30.3.1.2.2.4
Daily synchronisation time with the time server (hour: 0-23).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2-24VClockHrs 1.3.6.1.4.1.5040.1.2.30.3.1.2.3.1
Clock hours taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..23  

wtWebioEA2x2-24VClockMin 1.3.6.1.4.1.5040.1.2.30.3.1.2.3.2
Clock minutes taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..59  

wtWebioEA2x2-24VClockDay 1.3.6.1.4.1.5040.1.2.30.3.1.2.3.3
Date: Day of the month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..31  

wtWebioEA2x2-24VClockMonth 1.3.6.1.4.1.5040.1.2.30.3.1.2.3.4
Date: Month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA2x2-24VClockMonth-January(1), wtWebioEA2x2-24VClockMonth-February(2), wtWebioEA2x2-24VClockMonth-March(3), wtWebioEA2x2-24VClockMonth-April(4), wtWebioEA2x2-24VClockMonth-May(5), wtWebioEA2x2-24VClockMonth-June(6), wtWebioEA2x2-24VClockMonth-July(7), wtWebioEA2x2-24VClockMonth-August(8), wtWebioEA2x2-24VClockMonth-September(9), wtWebioEA2x2-24VClockMonth-October(10), wtWebioEA2x2-24VClockMonth-November(11), wtWebioEA2x2-24VClockMonth-December(12)  

wtWebioEA2x2-24VClockYear 1.3.6.1.4.1.5040.1.2.30.3.1.2.3.5
Date: Year, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA2x2-24VIpAddress 1.3.6.1.4.1.5040.1.2.30.3.1.3.1.1
IP address of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioEA2x2-24VSubnetMask 1.3.6.1.4.1.5040.1.2.30.3.1.3.1.2
Subnet mask of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioEA2x2-24VGateway 1.3.6.1.4.1.5040.1.2.30.3.1.3.1.3
Gateway of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioEA2x2-24VDnsServer1 1.3.6.1.4.1.5040.1.2.30.3.1.3.1.4
IP address of the 1st DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VDnsServer2 1.3.6.1.4.1.5040.1.2.30.3.1.3.1.5
IP address of the 2nd DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VAddConfig 1.3.6.1.4.1.5040.1.2.30.3.1.3.1.6
Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP enable Bit 0: BOOTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VStartup 1.3.6.1.4.1.5040.1.2.30.3.1.3.2.1
Binary coded start page, more than one page must not be selected: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2: user.htm Bit 1: home.htm Bit 0: index.htm
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VGetHeaderEnable 1.3.6.1.4.1.5040.1.2.30.3.1.3.2.2
If bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device (Header) or a HTTP header (HTTP): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2-7: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VHttpInputTrigger 1.3.6.1.4.1.5040.1.2.30.3.1.3.2.3
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2-24VHttpPort 1.3.6.1.4.1.5040.1.2.30.3.1.3.2.4
Definition of the standard HTML port (Default: 80).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65534  

wtWebioEA2x2-24VMailAdName 1.3.6.1.4.1.5040.1.2.30.3.1.3.3.1
Device name for mail administration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VMailReply 1.3.6.1.4.1.5040.1.2.30.3.1.3.3.2
Reply address for the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VMailServer 1.3.6.1.4.1.5040.1.2.30.3.1.3.3.3
Name or IP address of the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VMailEnable 1.3.6.1.4.1.5040.1.2.30.3.1.3.3.4
Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VMailAuthentication 1.3.6.1.4.1.5040.1.2.30.3.1.3.3.5
Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2-24VMailAuthUser 1.3.6.1.4.1.5040.1.2.30.3.1.3.3.6
Name of the user to be authenticated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VMailAuthPassword 1.3.6.1.4.1.5040.1.2.30.3.1.3.3.7
Authentication password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VMailPop3Server 1.3.6.1.4.1.5040.1.2.30.3.1.3.3.8
Name or Ip-address of the POP3 Servers.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VSnmpEnable 1.3.6.1.4.1.5040.1.2.30.3.1.3.4.1
Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VSnmpCommunityStringRead 1.3.6.1.4.1.5040.1.2.30.3.1.3.4.2
Community string read only
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VSnmpCommunityStringReadWrite 1.3.6.1.4.1.5040.1.2.30.3.1.3.4.3
Community string read / write
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VSnmpSystemTrapManagerIP 1.3.6.1.4.1.5040.1.2.30.3.1.3.4.4
Name or IP address of the TCP server which accepts the system trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VSnmpSystemTrapEnable 1.3.6.1.4.1.5040.1.2.30.3.1.3.4.5
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag messages Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2-24VUdpAdminPort 1.3.6.1.4.1.5040.1.2.30.3.1.3.5.1
Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2-24VUdpEnable 1.3.6.1.4.1.5040.1.2.30.3.1.3.5.2
Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VUdpRemotePort 1.3.6.1.4.1.5040.1.2.30.3.1.3.5.3
Udp remote port setting. If this value is set to zero, the source port read from a request will be used as destination port for the answer. A non zero value forced the destination port to this value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2-24VBinaryModeCount 1.3.6.1.4.1.5040.1.2.30.3.1.3.6.1
Number of independent binary channels.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtWebioEA2x2-24VBinaryIfTable 1.3.6.1.4.1.5040.1.2.30.3.1.3.6.2
Table of indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2-24VBinaryIfEntry

wtWebioEA2x2-24VBinaryIfEntry 1.3.6.1.4.1.5040.1.2.30.3.1.3.6.2.1
Indices of the binary channels.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2-24VBinaryIfEntry  

wtWebioEA2x2-24VBinaryModeNo 1.3.6.1.4.1.5040.1.2.30.3.1.3.6.2.1.1
Number of the binary channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtWebioEA2x2-24VBinaryTable 1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3
Table of properties of the binary mode.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2-24VBinaryEntry

wtWebioEA2x2-24VBinaryEntry 1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1
Binary properties.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2-24VBinaryEntry  

wtWebioEA2x2-24VBinaryOperationMode 1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.1
Selection of the operation mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : UDP Peer Bit 1 : TCP Client Bit 0 : TCP Server
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2-24VBinaryTcpServerLocalPort 1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.2
Local TCP port for data exchange in this server mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2-24VBinaryTcpServerInputTrigger 1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.3
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2-24VBinaryTcpServerApplicationMode 1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.4
Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 4-7: unused Bit 3 : OPC Device Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2-24VBinaryTcpClientLocalPort 1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.5
Local TCP port for data exchange in this client mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2-24VBinaryTcpClientServerPort 1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.6
Port number of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server port to zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2-24VBinaryTcpClientServerIpAddr 1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.7
Ip address of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server IP address to 0.0.0.0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VBinaryTcpClientServerPassword 1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.8
Building a connection may be protected by the administrator password of the server. Enter the server password to establish the connection, if a server administrator password exists.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VBinaryTcpClientInactivity 1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.9
Connection timeout in 100ms. If no data are exchanged within the specified time, the device closes the connection to the server. The value 0 deactivates the timer. Using the Box2Box mode this function is disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2-24VBinaryTcpClientInputTrigger 1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.10
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2-24VBinaryTcpClientInterval 1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.11
Configurable interval with a 100ms base, in which the Webio device sends data to the configured application. A interval of zero stopps the periodical sending.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA2x2-24VBinaryTcpClientApplicationMode 1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.12
Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2-24VBinaryUdpPeerLocalPort 1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.13
Local UDP port for data exchange in this peer to peer mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2-24VBinaryUdpPeerRemotePort 1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.14
Port number of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote port to zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2-24VBinaryUdpPeerRemoteIpAddr 1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.15
Ip address of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote device IP address to 0.0.0.0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VBinaryUdpPeerInputTrigger 1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.16
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2-24VBinaryUdpPeerInterval 1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.17
Configurable interval with a 100ms base, in which the Webio device sends data to the configured remote device. A interval of zero stopps the periodical sending.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA2x2-24VBinaryUdpPeerApplicationMode 1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.18
Selection of the application mode: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2-24VBinaryConnectedPort 1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.19
Port number of the remote device, after connection has been established. In case of no connection or missing port informations a zero will be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2-24VBinaryConnectedIpAddr 1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.20
IP address of the remote device, after connection has been established. In case of no connection or missing port informations 0.0.0.0 will be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

wtWebioEA2x2-24VBinaryTcpServerClientHttpPort 1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.21
HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs status informations will be send to this port. Not used at mode Compatible 50xxx.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2-24VBinaryTcpClientServerHttpPort 1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.22
HTTP port number of the remote device at TCP Client Mode. In the operating mode Box2Box connection status informations will be exchanged through this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2-24VSyslogServerIP 1.3.6.1.4.1.5040.1.2.30.3.1.3.7.1
Name or IP address of the Syslog server, which accepts the Syslog messgaes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VSyslogServerPort 1.3.6.1.4.1.5040.1.2.30.3.1.3.7.2
Portnumber of the Syslog servers, default 514.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2-24VSyslogSystemMessagesEnable 1.3.6.1.4.1.5040.1.2.30.3.1.3.7.3
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2-24VSyslogEnable 1.3.6.1.4.1.5040.1.2.30.3.1.3.7.4
Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VFTPServerIP 1.3.6.1.4.1.5040.1.2.30.3.1.3.8.1
Name or IP address of the FTP server, which accepts the FTP messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VFTPServerControlPort 1.3.6.1.4.1.5040.1.2.30.3.1.3.8.2
Portnumber of the control port of the FTP server, default 21.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2-24VFTPUserName 1.3.6.1.4.1.5040.1.2.30.3.1.3.8.3
FTP Loggin: user name.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VFTPPassword 1.3.6.1.4.1.5040.1.2.30.3.1.3.8.4
FTP Loggin: user password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VFTPAccount 1.3.6.1.4.1.5040.1.2.30.3.1.3.8.5
FTP Loggin: name of account.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VFTPOption 1.3.6.1.4.1.5040.1.2.30.3.1.3.8.6
Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VFTPEnable 1.3.6.1.4.1.5040.1.2.30.3.1.3.8.7
Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VOutputModeTable 1.3.6.1.4.1.5040.1.2.30.3.1.4.1
Table of output mode configurations dependent on the output indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2-24VOutputModeEntry

wtWebioEA2x2-24VOutputModeEntry 1.3.6.1.4.1.5040.1.2.30.3.1.4.1.1
Output mode configurations of the individual outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2-24VOutputModeEntry  

wtWebioEA2x2-24VOutputModeBit 1.3.6.1.4.1.5040.1.2.30.3.1.4.1.1.1
This binary coded output mode defines the individual operation mode for any output. More than one mode must not be selected. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 6-7: unused Bit 5 : Logic Bit 4 : Binary 2 Bit 3 : Binary 1 Bit 2 : SNMP Bit 1 : UDP ASCII Bit 0 : HTTP
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2-24VSafetyTimeout 1.3.6.1.4.1.5040.1.2.30.3.1.4.2
After this period of time (multiple of 100ms) without receiving data outputs switch to their Safety States. For each output a independend safety state could be defined.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA2x2-24VPowerSupplyEnable 1.3.6.1.4.1.5040.1.2.30.3.1.4.4
Setting this enable bit turns on the intarnal 24V power supply of the outputs. All currents out must not exceed 150mA. At overcurrent condition the power supply will be shut down automatically. To reset the ocvercurrent protection circuit write 1 into wtWebioEA2x2-24VDiagErrorClear. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Power Supply enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VAlarmCount 1.3.6.1.4.1.5040.1.2.30.3.1.5.1
Number of independent alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

wtWebioEA2x2-24VAlarmIfTable 1.3.6.1.4.1.5040.1.2.30.3.1.5.2
List of alarm indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2-24VAlarmIfEntry

wtWebioEA2x2-24VAlarmIfEntry 1.3.6.1.4.1.5040.1.2.30.3.1.5.2.1
Numbers of the alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2-24VAlarmIfEntry  

wtWebioEA2x2-24VAlarmNo 1.3.6.1.4.1.5040.1.2.30.3.1.5.2.1.1
Numbers of the alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

wtWebioEA2x2-24VAlarmTable 1.3.6.1.4.1.5040.1.2.30.3.1.5.3
List of settings depending on the alarm number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2-24VAlarmEntry

wtWebioEA2x2-24VAlarmEntry 1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1
Alarm parameters of the individual alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2-24VAlarmEntry  

wtWebioEA2x2-24VAlarmInputTrigger 1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.1
This variable allows setting of individual input trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the inputs are to be considered (corresponding bit = 1) and which inputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital inputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital inputs 0-1 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change of the corresponding input bit. Settings in OCTET 5-9 are then unused: OCTET 9: unused OCTET 10: unused OCTET 11: unused OCTET 12, Bit 0-1: ANY bits of digital inputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(12)  

wtWebioEA2x2-24VAlarmOutputTrigger 1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.2
This variable allows setting of individual output trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be considered (corresponding bit = 1) and which outputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital outputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital outputs 0-1 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change of the corresponding output bit. Settings in OCTET 5-9 are then unused: OCTET 9: unused OCTET 10: unused OCTET 11: unused OCTET 12, Bit 0-1: ANY bits of digital outputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(12)  

wtWebioEA2x2-24VAlarmSystemTrigger 1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.3
Binary coded trigger conditions: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Warm Start Bit 2 : Cold Start Bit 1 : Timer Bit 0 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2-24VAlarmMaxCounterValue 1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.4
This variable configures a max. counter value. If an input counter value exceeds this max. value, the corresponding alarm is triggered. Input counters with its mask bit unset in wtWebioEA2x2-24VAlarmInputTrigger are not considered.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VAlarmInterval 1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.5
Send interval for alarm messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VAlarmEnable 1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.6
Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: UDP enable Bit 3: Send inputs to pending TCP connections Bit 4: TCP Client enable Bit 5: Syslog Messages enable Bit 6-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2-24VAlarmMailAddr 1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.7
E-Mail address for sending the alarm mail to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VAlarmMailSubject 1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.8
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VAlarmMailText 1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.9
Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VAlarmSnmpManagerIP 1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.10
IP address of the SNMP Manager to which the Webio device should send SNMP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VAlarmSnmpTrapText 1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.11
This text appears in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VAlarmUdpIpAddr 1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.12
IP address of the UDP listener to which the Webio device should send UDP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VAlarmUdpPort 1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.13
Port number of the UDP listener to which the Webio device should send UDP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2-24VAlarmUdpText 1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.14
This text appears in the UDP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VAlarmTcpIpAddr 1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.15
IP address of the TCP listener to which the Webio device should send TCP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VAlarmTcpPort 1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.16
Port number of the TCP listener to which the Webio device should send TCP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2-24VAlarmTcpText 1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.17
This text appears in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VAlarmSyslogIpAddr 1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.18
IP address of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VAlarmSyslogPort 1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.19
Port number of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2-24VAlarmSyslogText 1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.20
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VAlarmFtpDataPort 1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.21
Local data port: 1..65535 or AUTO: the next free port will be assigned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VAlarmFtpFileName 1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.22
Name of the file including path informations.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VAlarmFtpText 1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.23
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VAlarmFtpOption 1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.24
Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2-24VAlarmTimerCron 1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.25
This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VAlarmMailReleaseSubject 1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.26
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VAlarmMailReleaseText 1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.27
Release Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VAlarmSnmpTrapReleaseText 1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.28
This text appears in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VAlarmUdpReleaseText 1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.29
This text appears in the UDP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VAlarmTcpReleaseText 1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.30
This text appears in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VAlarmSyslogReleaseText 1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.31
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VAlarmFtpReleaseText 1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.32
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VInputPortTable 1.3.6.1.4.1.5040.1.2.30.3.2.1
List of settings depending on the input number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2-24VInputPortEntry

wtWebioEA2x2-24VInputPortEntry 1.3.6.1.4.1.5040.1.2.30.3.2.1.1
Input parameter for the individual inputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2-24VInputPortEntry  

wtWebioEA2x2-24VPortInputName 1.3.6.1.4.1.5040.1.2.30.3.2.1.1.1
Name of the input.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VPortInputText 1.3.6.1.4.1.5040.1.2.30.3.2.1.1.2
Description of the input.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VPortInputMode 1.3.6.1.4.1.5040.1.2.30.3.2.1.1.3
Binary coded modes: Selecting short pulse detection enable by setting the corresponding bit to 1 enables interrupt support for counting. Only positive edges are accepted as trigger source. The maximum counting frequenz equals 2000 Hz. This mode is available for inputs 0-3 only. Selecting counter clear on read by setting the corresponding bit to 1 enables the corresponding counter to be cleared automatically every time it is read, except HTTP reading with user rights. The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. Selection for input 0-1: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Bidirectional counter enable Bit 2 : Counter clear on read Bit 1 : Change detection enable (default) Bit 0 : Short Pulse detection enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2-24VPortInputFilter 1.3.6.1.4.1.5040.1.2.30.3.2.1.1.4
Pulses with a duration shorter than here specified (duration in 1/1000 sec), are ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2-24VPortInputBicountPulsePolarity 1.3.6.1.4.1.5040.1.2.30.3.2.1.1.5
This value defines the polarity of the input pulse. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2-24VPortInputBicountInactivTimeout 1.3.6.1.4.1.5040.1.2.30.3.2.1.1.6
Pulse chains with a duration shorter than here specified (in 1/10 sek), are ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2-24VOutputPortTable 1.3.6.1.4.1.5040.1.2.30.3.2.2
List of settings depending on the output number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2-24VOutputPortEntry

wtWebioEA2x2-24VOutputPortEntry 1.3.6.1.4.1.5040.1.2.30.3.2.2.1
Output parameters of the individual outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2-24VOutputPortEntry  

wtWebioEA2x2-24VPortOutputName 1.3.6.1.4.1.5040.1.2.30.3.2.2.1.1
Name of the output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VPortOutputText 1.3.6.1.4.1.5040.1.2.30.3.2.2.1.2
Description of the output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VPortOutputGroupMode 1.3.6.1.4.1.5040.1.2.30.3.2.2.1.3
It is possible to connect outputs together to increase the output current. This could be done by connecting 2 or 4 outputs in a group together. All bits of such a group has to be set all together in the same way. This variable configures this group scheme. If one ouput bit of a group is set, all other output bits of the same group will be set in the same manner. More than one configuration must not be selected. Selection for ouputs 0-1: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: Bit 0 : ouputs 0,1 disconnected (default) Bit 1 : ouputs 0+1 connected
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VPortOutputSafetyState 1.3.6.1.4.1.5040.1.2.30.3.2.2.1.4
This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 1-7: unused Bit 0 : Mask for digital output OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs to be changed should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 1-7: unused Bit 0 : Level of digital output
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VPortLogicInputMask 1.3.6.1.4.1.5040.1.2.30.3.2.2.1.5
Selecting one of these inputs by setting the corresponding bit to 1 enables the logic function for the output identified by the index within this table. The calculation take place in 4 steps: 1. Selecting inputs (wtWebioEA2x2-24VPortLogicInputMask) 2. Inverting inputs if necessary (wtWebioEA2x2-24VPortLogicInputInverter) 3. Logical combination (wtWebioEA2x2-24VPortLogicFunction) 4. Inverting the result if necessary (wtWebioEA2x2-24VPortLogicOutputInverter) OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0-1 : inputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2-24VPortLogicInputInverter 1.3.6.1.4.1.5040.1.2.30.3.2.2.1.6
Every input bit selected here will be inverted. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0-1 : inputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2-24VPortLogicFunction 1.3.6.1.4.1.5040.1.2.30.3.2.2.1.7
This determines the logic function. No more than one function may be selected. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : logic function OR (default) Bit 1 : logic function AND Bit 2-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2-24VPortLogicOutputInverter 1.3.6.1.4.1.5040.1.2.30.3.2.2.1.8
The logical operation result could be inverteted by setting the corresponding bit to 1. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : Output Inverter enable Bit 1-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2-24VPortPulseDuration 1.3.6.1.4.1.5040.1.2.30.3.2.2.1.9
Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2-24VPortPulsePolarity 1.3.6.1.4.1.5040.1.2.30.3.2.2.1.10
This value defines the polarity of the output pulse, if wtWebioEA2x2-24VPortPulseDuration is not set to zero. After the pulse is finished, the output switches back to the opposite state. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2-24VMfName 1.3.6.1.4.1.5040.1.2.30.3.3.1
Manufacturer company name
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VMfAddr 1.3.6.1.4.1.5040.1.2.30.3.3.2
Manufacturer address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VMfHotline 1.3.6.1.4.1.5040.1.2.30.3.3.3
Manufacturer hotline.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VMfInternet 1.3.6.1.4.1.5040.1.2.30.3.3.4
Manufacturer Internet address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VMfDeviceTyp 1.3.6.1.4.1.5040.1.2.30.3.3.5
Manufacturer device name (model number).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VDiagErrorCount 1.3.6.1.4.1.5040.1.2.30.4.1
Number of entries in the error memory.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2-24VDiagBinaryError 1.3.6.1.4.1.5040.1.2.30.4.2
Error causes coded bit-by-bit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VDiagErrorIndex 1.3.6.1.4.1.5040.1.2.30.4.3
The value of this variable is used as an index to read an error massege from wtWebioEA2x2-24VDiagErrorMessage. Errors are numbered from 1 to wtWebioEA2x2-24VDiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebioEA2x2-24VDiagErrorMessage.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2-24VDiagErrorMessage 1.3.6.1.4.1.5040.1.2.30.4.4
Using wtWebioEA2x2-24VDiagErrorIndex as an index, the appropriate message is available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2-24VDiagErrorClear 1.3.6.1.4.1.5040.1.2.30.4.5
Writing 1 into this variable clears all diagnosis messages.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2-24VAlert1 41
This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2-24VAlert2 42
This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2-24VAlert3 43
This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2-24VAlert4 44
This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2-24VAlert5 45
This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2-24VAlert6 46
This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2-24VAlert7 47
This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2-24VAlert8 48
This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2-24VAlert9 49
This SNMP trap is generated when Alarm 9 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2-24VAlert10 50
This SNMP trap is generated when Alarm 10 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2-24VAlert11 51
This SNMP trap is generated when Alarm 11 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2-24VAlert12 52
This SNMP trap is generated when Alarm 12 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2-24VAlert13 71
This SNMP trap is generated when Alarm 1 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2-24VAlert14 72
This SNMP trap is generated when Alarm 2 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2-24VAlert15 73
This SNMP trap is generated when Alarm 3 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2-24VAlert16 74
This SNMP trap is generated when Alarm 4 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2-24VAlert17 75
This SNMP trap is generated when Alarm 5 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2-24VAlert18 76
This SNMP trap is generated when Alarm 6 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2-24VAlert19 77
This SNMP trap is generated when Alarm 7 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2-24VAlert20 78
This SNMP trap is generated when Alarm 8 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2-24VAlert21 79
This SNMP trap is generated when Alarm 9 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2-24VAlert22 80
This SNMP trap is generated when Alarm 10 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2-24VAlert23 81
This SNMP trap is generated when Alarm 11 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2-24VAlert24 82
This SNMP trap is generated when Alarm 12 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2-24VAlertDiag 110
This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERP-24VInputs 1.3.6.1.4.1.5040.1.2.31.1.1
Number of idependent inputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtWebioEA2x2ERP-24VOutputs 1.3.6.1.4.1.5040.1.2.31.1.2
Number of idependent outputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtWebioEA2x2ERP-24VInputTable 1.3.6.1.4.1.5040.1.2.31.1.3
List of input indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2ERP-24VInputEntry

wtWebioEA2x2ERP-24VInputEntry 1.3.6.1.4.1.5040.1.2.31.1.3.1
Number of the inputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2ERP-24VInputEntry  

wtWebioEA2x2ERP-24VInputNo 1.3.6.1.4.1.5040.1.2.31.1.3.1.1
Index numbers of the inputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebioEA2x2ERP-24VInputCounter 1.3.6.1.4.1.5040.1.2.31.1.3.1.2
Value of the input counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebioEA2x2ERP-24VInputCounterClear 1.3.6.1.4.1.5040.1.2.31.1.3.1.3
Clears the input counter after returning its value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERP-24VInputState 1.3.6.1.4.1.5040.1.2.31.1.3.1.4
Value of a single input bit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtWebioEA2x2ERP-24VInputState-OFF(0), wtWebioEA2x2ERP-24VInputState-ON(1)  

wtWebioEA2x2ERP-24VInputValue 1.3.6.1.4.1.5040.1.2.31.1.4
This variable is used to read the inputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital outputs 0-1
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERP-24VOutputTable 1.3.6.1.4.1.5040.1.2.31.1.5
List of output indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2ERP-24VOutputEntry

wtWebioEA2x2ERP-24VOutputEntry 1.3.6.1.4.1.5040.1.2.31.1.5.1
Number of the outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2ERP-24VOutputEntry  

wtWebioEA2x2ERP-24VOutputNo 1.3.6.1.4.1.5040.1.2.31.1.5.1.1
Output number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebioEA2x2ERP-24VOutputState 1.3.6.1.4.1.5040.1.2.31.1.5.1.2
Value of a single output bit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA2x2ERP-24VOutputState-OFF(0), wtWebioEA2x2ERP-24VOutputState-ON(1)  

wtWebioEA2x2ERP-24VOutputValue 1.3.6.1.4.1.5040.1.2.31.1.6
This variable is used to read and write the outputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital outputs 0-1 Bit 2-7: ungenutzt
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERP-24VSetOutput 1.3.6.1.4.1.5040.1.2.31.1.7
This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first two OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital outputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital outputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

wtWebioEA2x2ERP-24VSessCntrlPassword 1.3.6.1.4.1.5040.1.2.31.2.1
Entering this password opens a session which is ended by writing a 1 to wtWebioEA2x2ERP-24VSessCntrlLogout. When read this variable provides a string of length zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VSessCntrlConfigMode 1.3.6.1.4.1.5040.1.2.31.2.2
When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtWebioEA2x2ERP-24VSessCntrl-NoSession(0), wtWebioEA2x2ERP-24VSessCntrl-Session(1)  

wtWebioEA2x2ERP-24VSessCntrlLogout 1.3.6.1.4.1.5040.1.2.31.2.3
If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERP-24VSessCntrlAdminPassword 1.3.6.1.4.1.5040.1.2.31.2.4
This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VSessCntrlConfigPassword 1.3.6.1.4.1.5040.1.2.31.2.5
This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VDeviceName 1.3.6.1.4.1.5040.1.2.31.3.1.1.1
Name of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VDeviceText 1.3.6.1.4.1.5040.1.2.31.3.1.1.2
Description of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VDeviceLocation 1.3.6.1.4.1.5040.1.2.31.3.1.1.3
Description of the location of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VDeviceContact 1.3.6.1.4.1.5040.1.2.31.3.1.1.4
Contact address of the system operator of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VTzOffsetHrs 1.3.6.1.4.1.5040.1.2.31.3.1.2.1.1
Offset hours for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERP-24VTzOffsetMin 1.3.6.1.4.1.5040.1.2.31.3.1.2.1.2
Offset minutes for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERP-24VTzEnable 1.3.6.1.4.1.5040.1.2.31.3.1.2.1.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERP-24VStTzOffsetHrs 1.3.6.1.4.1.5040.1.2.31.3.1.2.1.4
Offset hours of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERP-24VStTzOffsetMin 1.3.6.1.4.1.5040.1.2.31.3.1.2.1.5
Offset minutes of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERP-24VStTzEnable 1.3.6.1.4.1.5040.1.2.31.3.1.2.1.6
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERP-24VStTzStartMonth 1.3.6.1.4.1.5040.1.2.31.3.1.2.1.7
Month in which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA2x2ERP-24VStartMonth-January(1), wtWebioEA2x2ERP-24VStartMonth-February(2), wtWebioEA2x2ERP-24VStartMonth-March(3), wtWebioEA2x2ERP-24VStartMonth-April(4), wtWebioEA2x2ERP-24VStartMonth-May(5), wtWebioEA2x2ERP-24VStartMonth-June(6), wtWebioEA2x2ERP-24VStartMonth-July(7), wtWebioEA2x2ERP-24VStartMonth-August(8), wtWebioEA2x2ERP-24VStartMonth-September(9), wtWebioEA2x2ERP-24VStartMonth-October(10), wtWebioEA2x2ERP-24VStartMonth-November(11), wtWebioEA2x2ERP-24VStartMonth-December(12)  

wtWebioEA2x2ERP-24VStTzStartMode 1.3.6.1.4.1.5040.1.2.31.3.1.2.1.8
Mode of the day of the week for which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA2x2ERP-24VStartMode-first(1), wtWebioEA2x2ERP-24VStartMode-second(2), wtWebioEA2x2ERP-24VStartMode-third(3), wtWebioEA2x2ERP-24VStartMode-fourth(4), wtWebioEA2x2ERP-24VStartMode-last(5)  

wtWebioEA2x2ERP-24VStTzStartWday 1.3.6.1.4.1.5040.1.2.31.3.1.2.1.9
Day of the week on which the change is made from winter time to summer time
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA2x2ERP-24VStartWday-Sunday(1), wtWebioEA2x2ERP-24VStartWday-Monday(2), wtWebioEA2x2ERP-24VStartWday-Tuesday(3), wtWebioEA2x2ERP-24VStartWday-Thursday(4), wtWebioEA2x2ERP-24VStartWday-Wednesday(5), wtWebioEA2x2ERP-24VStartWday-Friday(6), wtWebioEA2x2ERP-24VStartWday-Saturday(7)  

wtWebioEA2x2ERP-24VStTzStartHrs 1.3.6.1.4.1.5040.1.2.31.3.1.2.1.10
Hour in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERP-24VStTzStartMin 1.3.6.1.4.1.5040.1.2.31.3.1.2.1.11
Minute in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERP-24VStTzStopMonth 1.3.6.1.4.1.5040.1.2.31.3.1.2.1.12
Month in which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA2x2ERP-24VStopMonth-January(1), wtWebioEA2x2ERP-24VStopMonth-February(2), wtWebioEA2x2ERP-24VStopMonth-March(3), wtWebioEA2x2ERP-24VStopMonth-April(4), wtWebioEA2x2ERP-24VStopMonth-May(5), wtWebioEA2x2ERP-24VStopMonth-June(6), wtWebioEA2x2ERP-24VStopMonth-July(7), wtWebioEA2x2ERP-24VStopMonth-August(8), wtWebioEA2x2ERP-24VStopMonth-September(9), wtWebioEA2x2ERP-24VStopMonth-October(10), wtWebioEA2x2ERP-24VStopMonth-November(11), wtWebioEA2x2ERP-24VStopMonth-December(12)  

wtWebioEA2x2ERP-24VStTzStopMode 1.3.6.1.4.1.5040.1.2.31.3.1.2.1.13
Mode of the week day on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA2x2ERP-24VStopMode-first(1), wtWebioEA2x2ERP-24VStopMode-second(2), wtWebioEA2x2ERP-24VStopMode-third(3), wtWebioEA2x2ERP-24VStopMode-fourth(4), wtWebioEA2x2ERP-24VStopMode-last(5)  

wtWebioEA2x2ERP-24VStTzStopWday 1.3.6.1.4.1.5040.1.2.31.3.1.2.1.14
Day of the week on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA2x2ERP-24VStopWday-Sunday(1), wtWebioEA2x2ERP-24VStopWday-Monday(2), wtWebioEA2x2ERP-24VStopWday-Tuesday(3), wtWebioEA2x2ERP-24VStopWday-Thursday(4), wtWebioEA2x2ERP-24VStopWday-Wednesday(5), wtWebioEA2x2ERP-24VStopWday-Friday(6), wtWebioEA2x2ERP-24VStopWday-Saturday(7)  

wtWebioEA2x2ERP-24VStTzStopHrs 1.3.6.1.4.1.5040.1.2.31.3.1.2.1.15
Hour at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERP-24VStTzStopMin 1.3.6.1.4.1.5040.1.2.31.3.1.2.1.16
Minute at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERP-24VTimeServer1 1.3.6.1.4.1.5040.1.2.31.3.1.2.2.1
IP address or name of the 1st time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VTimeServer2 1.3.6.1.4.1.5040.1.2.31.3.1.2.2.2
IP address or name of the 2nd time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VTsEnable 1.3.6.1.4.1.5040.1.2.31.3.1.2.2.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERP-24VTsSyncTime 1.3.6.1.4.1.5040.1.2.31.3.1.2.2.4
Daily synchronisation time with the time server (hour: 0-23).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERP-24VClockHrs 1.3.6.1.4.1.5040.1.2.31.3.1.2.3.1
Clock hours taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..23  

wtWebioEA2x2ERP-24VClockMin 1.3.6.1.4.1.5040.1.2.31.3.1.2.3.2
Clock minutes taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..59  

wtWebioEA2x2ERP-24VClockDay 1.3.6.1.4.1.5040.1.2.31.3.1.2.3.3
Date: Day of the month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..31  

wtWebioEA2x2ERP-24VClockMonth 1.3.6.1.4.1.5040.1.2.31.3.1.2.3.4
Date: Month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioEA2x2ERP-24VClockMonth-January(1), wtWebioEA2x2ERP-24VClockMonth-February(2), wtWebioEA2x2ERP-24VClockMonth-March(3), wtWebioEA2x2ERP-24VClockMonth-April(4), wtWebioEA2x2ERP-24VClockMonth-May(5), wtWebioEA2x2ERP-24VClockMonth-June(6), wtWebioEA2x2ERP-24VClockMonth-July(7), wtWebioEA2x2ERP-24VClockMonth-August(8), wtWebioEA2x2ERP-24VClockMonth-September(9), wtWebioEA2x2ERP-24VClockMonth-October(10), wtWebioEA2x2ERP-24VClockMonth-November(11), wtWebioEA2x2ERP-24VClockMonth-December(12)  

wtWebioEA2x2ERP-24VClockYear 1.3.6.1.4.1.5040.1.2.31.3.1.2.3.5
Date: Year, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA2x2ERP-24VIpAddress 1.3.6.1.4.1.5040.1.2.31.3.1.3.1.1
IP address of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioEA2x2ERP-24VSubnetMask 1.3.6.1.4.1.5040.1.2.31.3.1.3.1.2
Subnet mask of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioEA2x2ERP-24VGateway 1.3.6.1.4.1.5040.1.2.31.3.1.3.1.3
Gateway of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioEA2x2ERP-24VDnsServer1 1.3.6.1.4.1.5040.1.2.31.3.1.3.1.4
IP address of the 1st DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VDnsServer2 1.3.6.1.4.1.5040.1.2.31.3.1.3.1.5
IP address of the 2nd DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VAddConfig 1.3.6.1.4.1.5040.1.2.31.3.1.3.1.6
Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP enable Bit 0: BOOTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VStartup 1.3.6.1.4.1.5040.1.2.31.3.1.3.2.1
Binary coded start page, more than one page must not be selected: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2: user.htm Bit 1: home.htm Bit 0: index.htm
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VGetHeaderEnable 1.3.6.1.4.1.5040.1.2.31.3.1.3.2.2
If bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device (Header) or a HTTP header (HTTP): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2-7: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VHttpInputTrigger 1.3.6.1.4.1.5040.1.2.31.3.1.3.2.3
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERP-24VHttpPort 1.3.6.1.4.1.5040.1.2.31.3.1.3.2.4
Definition of the standard HTML port (Default: 80).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65534  

wtWebioEA2x2ERP-24VMailAdName 1.3.6.1.4.1.5040.1.2.31.3.1.3.3.1
Device name for mail administration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VMailReply 1.3.6.1.4.1.5040.1.2.31.3.1.3.3.2
Reply address for the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VMailServer 1.3.6.1.4.1.5040.1.2.31.3.1.3.3.3
Name or IP address of the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VMailEnable 1.3.6.1.4.1.5040.1.2.31.3.1.3.3.4
Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VMailAuthentication 1.3.6.1.4.1.5040.1.2.31.3.1.3.3.5
Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERP-24VMailAuthUser 1.3.6.1.4.1.5040.1.2.31.3.1.3.3.6
Name of the user to be authenticated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VMailAuthPassword 1.3.6.1.4.1.5040.1.2.31.3.1.3.3.7
Authentication password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VMailPop3Server 1.3.6.1.4.1.5040.1.2.31.3.1.3.3.8
Name or Ip-address of the POP3 Servers.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VSnmpEnable 1.3.6.1.4.1.5040.1.2.31.3.1.3.4.1
Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VSnmpCommunityStringRead 1.3.6.1.4.1.5040.1.2.31.3.1.3.4.2
Community string read only
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VSnmpCommunityStringReadWrite 1.3.6.1.4.1.5040.1.2.31.3.1.3.4.3
Community string read / write
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VSnmpSystemTrapManagerIP 1.3.6.1.4.1.5040.1.2.31.3.1.3.4.4
Name or IP address of the TCP server which accepts the system trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VSnmpSystemTrapEnable 1.3.6.1.4.1.5040.1.2.31.3.1.3.4.5
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag messages Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERP-24VUdpAdminPort 1.3.6.1.4.1.5040.1.2.31.3.1.3.5.1
Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERP-24VUdpEnable 1.3.6.1.4.1.5040.1.2.31.3.1.3.5.2
Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VUdpRemotePort 1.3.6.1.4.1.5040.1.2.31.3.1.3.5.3
Udp remote port setting. If this value is set to zero, the source port read from a request will be used as destination port for the answer. A non zero value forced the destination port to this value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERP-24VBinaryModeCount 1.3.6.1.4.1.5040.1.2.31.3.1.3.6.1
Number of independent binary channels.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtWebioEA2x2ERP-24VBinaryIfTable 1.3.6.1.4.1.5040.1.2.31.3.1.3.6.2
Table of indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2ERP-24VBinaryIfEntry

wtWebioEA2x2ERP-24VBinaryIfEntry 1.3.6.1.4.1.5040.1.2.31.3.1.3.6.2.1
Indices of the binary channels.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2ERP-24VBinaryIfEntry  

wtWebioEA2x2ERP-24VBinaryModeNo 1.3.6.1.4.1.5040.1.2.31.3.1.3.6.2.1.1
Number of the binary channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtWebioEA2x2ERP-24VBinaryTable 1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3
Table of properties of the binary mode.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2ERP-24VBinaryEntry

wtWebioEA2x2ERP-24VBinaryEntry 1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1
Binary properties.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2ERP-24VBinaryEntry  

wtWebioEA2x2ERP-24VBinaryOperationMode 1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.1
Selection of the operation mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : UDP Peer Bit 1 : TCP Client Bit 0 : TCP Server
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERP-24VBinaryTcpServerLocalPort 1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.2
Local TCP port for data exchange in this server mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2ERP-24VBinaryTcpServerInputTrigger 1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.3
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERP-24VBinaryTcpServerApplicationMode 1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.4
Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 4-7: unused Bit 3 : OPC Device Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERP-24VBinaryTcpClientLocalPort 1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.5
Local TCP port for data exchange in this client mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2ERP-24VBinaryTcpClientServerPort 1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.6
Port number of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server port to zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2ERP-24VBinaryTcpClientServerIpAddr 1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.7
Ip address of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server IP address to 0.0.0.0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VBinaryTcpClientServerPassword 1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.8
Building a connection may be protected by the administrator password of the server. Enter the server password to establish the connection, if a server administrator password exists.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VBinaryTcpClientInactivity 1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.9
Connection timeout in 100ms. If no data are exchanged within the specified time, the device closes the connection to the server. The value 0 deactivates the timer. Using the Box2Box mode this function is disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERP-24VBinaryTcpClientInputTrigger 1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.10
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERP-24VBinaryTcpClientInterval 1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.11
Configurable interval with a 100ms base, in which the Webio device sends data to the configured application. A interval of zero stopps the periodical sending.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA2x2ERP-24VBinaryTcpClientApplicationMode 1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.12
Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERP-24VBinaryUdpPeerLocalPort 1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.13
Local UDP port for data exchange in this peer to peer mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2ERP-24VBinaryUdpPeerRemotePort 1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.14
Port number of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote port to zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2ERP-24VBinaryUdpPeerRemoteIpAddr 1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.15
Ip address of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote device IP address to 0.0.0.0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VBinaryUdpPeerInputTrigger 1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.16
Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input bits. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital inputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERP-24VBinaryUdpPeerInterval 1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.17
Configurable interval with a 100ms base, in which the Webio device sends data to the configured remote device. A interval of zero stopps the periodical sending.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA2x2ERP-24VBinaryUdpPeerApplicationMode 1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.18
Selection of the application mode: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERP-24VBinaryConnectedPort 1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.19
Port number of the remote device, after connection has been established. In case of no connection or missing port informations a zero will be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2ERP-24VBinaryConnectedIpAddr 1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.20
IP address of the remote device, after connection has been established. In case of no connection or missing port informations 0.0.0.0 will be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

wtWebioEA2x2ERP-24VBinaryTcpServerClientHttpPort 1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.21
HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs status informations will be send to this port. Not used at mode Compatible 50xxx.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2ERP-24VBinaryTcpClientServerHttpPort 1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.22
HTTP port number of the remote device at TCP Client Mode. In the operating mode Box2Box connection status informations will be exchanged through this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2ERP-24VSyslogServerIP 1.3.6.1.4.1.5040.1.2.31.3.1.3.7.1
Name or IP address of the Syslog server, which accepts the Syslog messgaes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VSyslogServerPort 1.3.6.1.4.1.5040.1.2.31.3.1.3.7.2
Portnumber of the Syslog servers, default 514.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERP-24VSyslogSystemMessagesEnable 1.3.6.1.4.1.5040.1.2.31.3.1.3.7.3
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERP-24VSyslogEnable 1.3.6.1.4.1.5040.1.2.31.3.1.3.7.4
Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VFTPServerIP 1.3.6.1.4.1.5040.1.2.31.3.1.3.8.1
Name or IP address of the FTP server, which accepts the FTP messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VFTPServerControlPort 1.3.6.1.4.1.5040.1.2.31.3.1.3.8.2
Portnumber of the control port of the FTP server, default 21.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERP-24VFTPUserName 1.3.6.1.4.1.5040.1.2.31.3.1.3.8.3
FTP Loggin: user name.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VFTPPassword 1.3.6.1.4.1.5040.1.2.31.3.1.3.8.4
FTP Loggin: user password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VFTPAccount 1.3.6.1.4.1.5040.1.2.31.3.1.3.8.5
FTP Loggin: name of account.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VFTPOption 1.3.6.1.4.1.5040.1.2.31.3.1.3.8.6
Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VFTPEnable 1.3.6.1.4.1.5040.1.2.31.3.1.3.8.7
Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VWayBackEnable 1.3.6.1.4.1.5040.1.2.31.3.1.3.10.1
Set Bit 0 to enable WayBack: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : WayBack enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VWayBackServerControlPort 1.3.6.1.4.1.5040.1.2.31.3.1.3.10.2
Portnumber of the control port of the FTP server, default 21.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERP-24VWayBackFTPPassword 1.3.6.1.4.1.5040.1.2.31.3.1.3.10.3
WayBack FTP Loggin: Password of the user.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VWayBackFTPResponse 1.3.6.1.4.1.5040.1.2.31.3.1.3.10.4
WayBack FTP response: return message after login.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VWayBackFTPTimeOut 1.3.6.1.4.1.5040.1.2.31.3.1.3.10.5
WayBack FTP Timeout: a request must be finished within this periode of time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VOutputModeTable 1.3.6.1.4.1.5040.1.2.31.3.1.4.1
Table of output mode configurations dependent on the output indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2ERP-24VOutputModeEntry

wtWebioEA2x2ERP-24VOutputModeEntry 1.3.6.1.4.1.5040.1.2.31.3.1.4.1.1
Output mode configurations of the individual outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2ERP-24VOutputModeEntry  

wtWebioEA2x2ERP-24VOutputModeBit 1.3.6.1.4.1.5040.1.2.31.3.1.4.1.1.1
This binary coded output mode defines the individual operation mode for any output. More than one mode must not be selected. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 6-7: unused Bit 5 : Logic Bit 4 : Binary 2 Bit 3 : Binary 1 Bit 2 : SNMP Bit 1 : UDP ASCII Bit 0 : HTTP
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERP-24VSafetyTimeout 1.3.6.1.4.1.5040.1.2.31.3.1.4.2
After this period of time (multiple of 100ms) without receiving data outputs switch to their Safety States. For each output a independend safety state could be defined.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioEA2x2ERP-24VLoadControlEnable 1.3.6.1.4.1.5040.1.2.31.3.1.4.3
Here the function of automatic load control can be enabled. All output were tested in pairs (0-1). If an error occours at one output, both output of an pair will be switched of. For a properly function of the load control each output of a pair have to has a load. If there is no existing load, a pull down resistor can be used. Outputs with no load are automaticly detected and not part of the control function. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Load Control enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VPowerSupplyEnable 1.3.6.1.4.1.5040.1.2.31.3.1.4.4
Setting this enable bit turns on the intarnal 24V power supply of the outputs. All currents out must not exceed 150mA. At overcurrent condition the power supply will be shut down automatically. To reset the ocvercurrent protection circuit write 1 into wtWebioEA2x2DiagErrorClear. Internal power supply is a feature of 57638 only. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Power Supply enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VAlarmCount 1.3.6.1.4.1.5040.1.2.31.3.1.5.1
Number of independent alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

wtWebioEA2x2ERP-24VAlarmIfTable 1.3.6.1.4.1.5040.1.2.31.3.1.5.2
List of alarm indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2ERP-24VAlarmIfEntry

wtWebioEA2x2ERP-24VAlarmIfEntry 1.3.6.1.4.1.5040.1.2.31.3.1.5.2.1
Numbers of the alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2ERP-24VAlarmIfEntry  

wtWebioEA2x2ERP-24VAlarmNo 1.3.6.1.4.1.5040.1.2.31.3.1.5.2.1.1
Numbers of the alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

wtWebioEA2x2ERP-24VAlarmTable 1.3.6.1.4.1.5040.1.2.31.3.1.5.3
List of settings depending on the alarm number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2ERP-24VAlarmEntry

wtWebioEA2x2ERP-24VAlarmEntry 1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1
Alarm parameters of the individual alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2ERP-24VAlarmEntry  

wtWebioEA2x2ERP-24VAlarmInputTrigger 1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.1
This variable allows setting of individual input trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the inputs are to be considered (corresponding bit = 1) and which inputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital inputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital inputs 0-1 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change of the corresponding input bit. Settings in OCTET 5-9 are then unused: OCTET 9: unused OCTET 10: unused OCTET 11: unused OCTET 12, Bit 0-1: ANY bits of digital inputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(12)  

wtWebioEA2x2ERP-24VAlarmOutputTrigger 1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.2
This variable allows setting of individual output trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be considered (corresponding bit = 1) and which outputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital outputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital outputs 0-1 OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change of the corresponding output bit. Settings in OCTET 5-9 are then unused: OCTET 9: unused OCTET 10: unused OCTET 11: unused OCTET 12, Bit 0-1: ANY bits of digital outputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(12)  

wtWebioEA2x2ERP-24VAlarmSystemTrigger 1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.3
Binary coded trigger conditions: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Warm Start Bit 2 : Cold Start Bit 1 : Timer Bit 0 : Load Control
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERP-24VAlarmMaxCounterValue 1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.4
This variable configures a max. counter value. If an input counter value exceeds this max. value, the corresponding alarm is triggered. Input counters with its mask bit unset in wtWebioEA2x2ERP-24VAlarmInputTrigger are not considered.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VAlarmInterval 1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.5
Send interval for alarm messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VAlarmEnable 1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.6
Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: UDP enable Bit 3: Send inputs to pending TCP connections Bit 4: TCP Client enable Bit 5: Syslog Messages enable Bit 6-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERP-24VAlarmMailAddr 1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.7
E-Mail address for sending the alarm mail to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VAlarmMailSubject 1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.8
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VAlarmMailText 1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.9
Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VAlarmSnmpManagerIP 1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.10
IP address of the SNMP Manager to which the Webio device should send SNMP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VAlarmSnmpTrapText 1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.11
This text appears in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VAlarmUdpIpAddr 1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.12
IP address of the UDP listener to which the Webio device should send UDP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VAlarmUdpPort 1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.13
Port number of the UDP listener to which the Webio device should send UDP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2ERP-24VAlarmUdpText 1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.14
This text appears in the UDP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VAlarmTcpIpAddr 1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.15
IP address of the TCP listener to which the Webio device should send TCP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VAlarmTcpPort 1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.16
Port number of the TCP listener to which the Webio device should send TCP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2ERP-24VAlarmTcpText 1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.17
This text appears in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VAlarmSyslogIpAddr 1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.18
IP address of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VAlarmSyslogPort 1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.19
Port number of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioEA2x2ERP-24VAlarmSyslogText 1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.20
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VAlarmFtpDataPort 1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.21
Local data port: 1..65535 or AUTO: the next free port will be assigned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VAlarmFtpFileName 1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.22
Name of the file including path informations.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VAlarmFtpText 1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.23
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VAlarmFtpOption 1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.24
Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERP-24VAlarmTimerCron 1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.25
This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VAlarmMailReleaseSubject 1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.26
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VAlarmMailReleaseText 1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.27
Release Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VAlarmSnmpTrapReleaseText 1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.28
This text appears in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VAlarmUdpReleaseText 1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.29
This text appears in the UDP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VAlarmTcpReleaseText 1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.30
This text appears in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VAlarmSyslogReleaseText 1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.31
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VAlarmFtpReleaseText 1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.32
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VLoadControlView 1.3.6.1.4.1.5040.1.2.31.3.1.5.4
Here the result of automatic load control can be read. All output were tested in pairs (0-1). If an error occours at one output, both output of an pair will be switched of. For a properly function of the load control each output of a pair have to has a load. If there is no existing load, a pull down resistor can be used. Outputs with no load are automaticly detected and not part of the control function. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0-1: outputs 0-1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERP-24VLCShutDownView 1.3.6.1.4.1.5040.1.2.31.3.1.5.5
Here the result of the automatic load control shut down can be read. All outputs remain switched of, until a zero is written into this variable. But previously all loads should be inspected. High current (short circuit), a broken supply line or a defect load (i.e. lamp) may be a shut down reason. If no load is detected, the load control unit suspend automaticly the control of the corresponding output pair. All controlled output could be identified reading the variable wtWebioEA2x2ERP-24VLoadControlEnable. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an ouput. Bit 0 corresponds to the LSB. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0-1: outputs 0-1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERP-24VInputPortTable 1.3.6.1.4.1.5040.1.2.31.3.2.1
List of settings depending on the input number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2ERP-24VInputPortEntry

wtWebioEA2x2ERP-24VInputPortEntry 1.3.6.1.4.1.5040.1.2.31.3.2.1.1
Input parameter for the individual inputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2ERP-24VInputPortEntry  

wtWebioEA2x2ERP-24VPortInputName 1.3.6.1.4.1.5040.1.2.31.3.2.1.1.1
Name of the input.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VPortInputText 1.3.6.1.4.1.5040.1.2.31.3.2.1.1.2
Description of the input.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VPortInputMode 1.3.6.1.4.1.5040.1.2.31.3.2.1.1.3
Binary coded modes: Selecting short pulse detection enable by setting the corresponding bit to 1 enables interrupt support for counting. Only positive edges are accepted as trigger source. The maximum counting frequenz equals 2000 Hz. This mode is available for inputs 0-3 only. Selecting counter clear on read by setting the corresponding bit to 1 enables the corresponding counter to be cleared automatically every time it is read, except HTTP reading with user rights. The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. Selection for input 0-1: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Bidirectional counter enable Bit 2 : Counter clear on read Bit 1 : Change detection enable (default) Bit 0 : Short Pulse detection enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERP-24VPortInputFilter 1.3.6.1.4.1.5040.1.2.31.3.2.1.1.4
Pulses with a duration shorter than here specified (duration in 1/1000 sec), are ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERP-24VPortInputBicountPulsePolarity 1.3.6.1.4.1.5040.1.2.31.3.2.1.1.5
This value defines the polarity of the input pulse. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERP-24VPortInputBicountInactivTimeout 1.3.6.1.4.1.5040.1.2.31.3.2.1.1.6
Pulse chains with a duration shorter than here specified (in 1/10 sek), are ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERP-24VOutputPortTable 1.3.6.1.4.1.5040.1.2.31.3.2.2
List of settings depending on the output number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioEA2x2ERP-24VOutputPortEntry

wtWebioEA2x2ERP-24VOutputPortEntry 1.3.6.1.4.1.5040.1.2.31.3.2.2.1
Output parameters of the individual outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioEA2x2ERP-24VOutputPortEntry  

wtWebioEA2x2ERP-24VPortOutputName 1.3.6.1.4.1.5040.1.2.31.3.2.2.1.1
Name of the output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VPortOutputText 1.3.6.1.4.1.5040.1.2.31.3.2.2.1.2
Description of the output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VPortOutputGroupMode 1.3.6.1.4.1.5040.1.2.31.3.2.2.1.3
It is possible to connect outputs together to increase the output current. This could be done by connecting 2 or 4 outputs in a group together. All bits of such a group has to be set all together in the same way. This variable configures this group scheme. If one ouput bit of a group is set, all other output bits of the same group will be set in the same manner. More than one configuration must not be selected. Selection for ouputs 0-1: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: Bit 0 : ouputs 0,1 disconnected (default) Bit 1 : ouputs 0+1 connected
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VPortOutputSafetyState 1.3.6.1.4.1.5040.1.2.31.3.2.2.1.4
This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 1-7: unused Bit 0 : Mask for digital output OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs to be changed should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 1-7: unused Bit 0 : Level of digital output
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VPortLogicInputMask 1.3.6.1.4.1.5040.1.2.31.3.2.2.1.5
Selecting one of these inputs by setting the corresponding bit to 1 enables the logic function for the output identified by the index within this table. The calculation take place in 4 steps: 1. Selecting inputs (wtWebioEA2x2ERP-24VPortLogicInputMask) 2. Inverting inputs if necessary (wtWebioEA2x2ERP-24VPortLogicInputInverter) 3. Logical combination (wtWebioEA2x2ERP-24VPortLogicFunction) 4. Inverting the result if necessary (wtWebioEA2x2ERP-24VPortLogicOutputInverter) OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0-1 : inputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERP-24VPortLogicInputInverter 1.3.6.1.4.1.5040.1.2.31.3.2.2.1.6
Every input bit selected here will be inverted. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0-1 : inputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERP-24VPortLogicFunction 1.3.6.1.4.1.5040.1.2.31.3.2.2.1.7
This determines the logic function. No more than one function may be selected. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : logic function OR (default) Bit 1 : logic function AND Bit 2-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERP-24VPortLogicOutputInverter 1.3.6.1.4.1.5040.1.2.31.3.2.2.1.8
The logical operation result could be inverteted by setting the corresponding bit to 1. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : Output Inverter enable Bit 1-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERP-24VPortPulseDuration 1.3.6.1.4.1.5040.1.2.31.3.2.2.1.9
Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERP-24VPortPulsePolarity 1.3.6.1.4.1.5040.1.2.31.3.2.2.1.10
This value defines the polarity of the output pulse, if wtWebioEA2x2ERP-24VPortPulseDuration is not set to zero. After the pulse is finished, the output switches back to the opposite state. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioEA2x2ERP-24VMfName 1.3.6.1.4.1.5040.1.2.31.3.3.1
Manufacturer company name
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VMfAddr 1.3.6.1.4.1.5040.1.2.31.3.3.2
Manufacturer address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VMfHotline 1.3.6.1.4.1.5040.1.2.31.3.3.3
Manufacturer hotline.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VMfInternet 1.3.6.1.4.1.5040.1.2.31.3.3.4
Manufacturer Internet address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VMfDeviceTyp 1.3.6.1.4.1.5040.1.2.31.3.3.5
Manufacturer device name (model number).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VDiagErrorCount 1.3.6.1.4.1.5040.1.2.31.4.1
Number of entries in the error memory.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERP-24VDiagBinaryError 1.3.6.1.4.1.5040.1.2.31.4.2
Error causes coded bit-by-bit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VDiagErrorIndex 1.3.6.1.4.1.5040.1.2.31.4.3
The value of this variable is used as an index to read an error massege from wtWebioEA2x2ERP-24VDiagErrorMessage. Errors are numbered from 1 to wtWebioEA2x2ERP-24VDiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebioEA2x2ERP-24VDiagErrorMessage.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERP-24VDiagErrorMessage 1.3.6.1.4.1.5040.1.2.31.4.4
Using wtWebioEA2x2ERP-24VDiagErrorIndex as an index, the appropriate message is available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebioEA2x2ERP-24VDiagErrorClear 1.3.6.1.4.1.5040.1.2.31.4.5
Writing 1 into this variable clears all diagnosis messages.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER  

wtWebioEA2x2ERP-24VAlert1 41
This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERP-24VAlert2 42
This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERP-24VAlert3 43
This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERP-24VAlert4 44
This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERP-24VAlert5 45
This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERP-24VAlert6 46
This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERP-24VAlert7 47
This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERP-24VAlert8 48
This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERP-24VAlert9 49
This SNMP trap is generated when Alarm 9 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERP-24VAlert10 50
This SNMP trap is generated when Alarm 10 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERP-24VAlert11 51
This SNMP trap is generated when Alarm 11 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERP-24VAlert12 52
This SNMP trap is generated when Alarm 12 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERP-24VAlert13 71
This SNMP trap is generated when Alarm 1 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERP-24VAlert14 72
This SNMP trap is generated when Alarm 2 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERP-24VAlert15 73
This SNMP trap is generated when Alarm 3 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERP-24VAlert16 74
This SNMP trap is generated when Alarm 4 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERP-24VAlert17 75
This SNMP trap is generated when Alarm 5 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERP-24VAlert18 76
This SNMP trap is generated when Alarm 6 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERP-24VAlert19 77
This SNMP trap is generated when Alarm 7 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERP-24VAlert20 78
This SNMP trap is generated when Alarm 8 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERP-24VAlert21 79
This SNMP trap is generated when Alarm 9 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERP-24VAlert22 80
This SNMP trap is generated when Alarm 10 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERP-24VAlert23 81
This SNMP trap is generated when Alarm 11 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERP-24VAlert24 82
This SNMP trap is generated when Alarm 12 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioEA2x2ERP-24VAlertDiag 110
This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VInputs 1.3.6.1.4.1.5040.1.2.32.1.1
Number of idependent inputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtIpWatcher-24VOutputs 1.3.6.1.4.1.5040.1.2.32.1.2
Number of idependent outputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtIpWatcher-24VInputTable 1.3.6.1.4.1.5040.1.2.32.1.3
List of input indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtIpWatcher-24VInputEntry

wtIpWatcher-24VInputEntry 1.3.6.1.4.1.5040.1.2.32.1.3.1
Number of the inputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtIpWatcher-24VInputEntry  

wtIpWatcher-24VInputNo 1.3.6.1.4.1.5040.1.2.32.1.3.1.1
Index numbers of the inputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtIpWatcher-24VInputCounter 1.3.6.1.4.1.5040.1.2.32.1.3.1.2
Value of the input counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtIpWatcher-24VInputCounterClear 1.3.6.1.4.1.5040.1.2.32.1.3.1.3
Clears the input counter after returning its value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtIpWatcher-24VInputState 1.3.6.1.4.1.5040.1.2.32.1.3.1.4
Value of a single input bit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtIpWatcher-24VInputState-OFF(0), wtIpWatcher-24VInputState-ON(1)  

wtIpWatcher-24VInputValue 1.3.6.1.4.1.5040.1.2.32.1.4
This variable is used to read the inputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital outputs 0-1
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtIpWatcher-24VOutputTable 1.3.6.1.4.1.5040.1.2.32.1.5
List of output indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtIpWatcher-24VOutputEntry

wtIpWatcher-24VOutputEntry 1.3.6.1.4.1.5040.1.2.32.1.5.1
Number of the outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtIpWatcher-24VOutputEntry  

wtIpWatcher-24VOutputNo 1.3.6.1.4.1.5040.1.2.32.1.5.1.1
Output number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtIpWatcher-24VOutputState 1.3.6.1.4.1.5040.1.2.32.1.5.1.2
Value of a single output bit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtIpWatcher-24VOutputState-OFF(0), wtIpWatcher-24VOutputState-ON(1)  

wtIpWatcher-24VOutputValue 1.3.6.1.4.1.5040.1.2.32.1.6
This variable is used to read and write the outputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital outputs 0-1 Bit 2-7: ungenutzt
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcher-24VSetOutput 1.3.6.1.4.1.5040.1.2.32.1.7
This variable allows setting of individual digital outputs. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. The first two OCTETS contain the mask which determines which of the outputs are to be set (corresponding bit = 1) and which outputs are to remain unchanged (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital outputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital outputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

wtIpWatcher-24VAlarmOutputTable 1.3.6.1.4.1.5040.1.2.32.1.8
List of alarm indices..
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtIpWatcher-24VAlarmOutputEntry

wtIpWatcher-24VAlarmOutputEntry 1.3.6.1.4.1.5040.1.2.32.1.8.1
Index reference.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtIpWatcher-24VAlarmOutputEntry  

wtIpWatcher-24VAlarmOutputState 1.3.6.1.4.1.5040.1.2.32.1.8.1.1
State of the alarm.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtIpWatcher-24VAlarmOutputState-OFF(0), wtIpWatcher-24VAlarmOutputState-ON(1)  

wtIpWatcher-24VAlarmTriggerState 1.3.6.1.4.1.5040.1.2.32.1.8.1.2
State of the trigger condition.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtIpWatcher-24VAlarmTriggerState-OFF(0), wtIpWatcher-24VAlarmTriggerState-ON(1)  

wtIpWatcher-24VSessCntrlPassword 1.3.6.1.4.1.5040.1.2.32.2.1
Entering this password opens a session which is ended by writing a 1 to wtIpWatcher-24VSessCntrlLogout. When read this variable provides a string of length zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VSessCntrlConfigMode 1.3.6.1.4.1.5040.1.2.32.2.2
When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtIpWatcher-24VSessCntrl-NoSession(0), wtIpWatcher-24VSessCntrl-Session(1)  

wtIpWatcher-24VSessCntrlLogout 1.3.6.1.4.1.5040.1.2.32.2.3
If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcher-24VSessCntrlAdminPassword 1.3.6.1.4.1.5040.1.2.32.2.4
This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VSessCntrlConfigPassword 1.3.6.1.4.1.5040.1.2.32.2.5
This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VDeviceName 1.3.6.1.4.1.5040.1.2.32.3.1.1.1
Name of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VDeviceText 1.3.6.1.4.1.5040.1.2.32.3.1.1.2
Description of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VDeviceLocation 1.3.6.1.4.1.5040.1.2.32.3.1.1.3
Description of the location of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VDeviceContact 1.3.6.1.4.1.5040.1.2.32.3.1.1.4
Contact address of the system operator of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VTzOffsetHrs 1.3.6.1.4.1.5040.1.2.32.3.1.2.1.1
Offset hours for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcher-24VTzOffsetMin 1.3.6.1.4.1.5040.1.2.32.3.1.2.1.2
Offset minutes for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcher-24VTzEnable 1.3.6.1.4.1.5040.1.2.32.3.1.2.1.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtIpWatcher-24VStTzOffsetHrs 1.3.6.1.4.1.5040.1.2.32.3.1.2.1.4
Offset hours of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcher-24VStTzOffsetMin 1.3.6.1.4.1.5040.1.2.32.3.1.2.1.5
Offset minutes of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcher-24VStTzEnable 1.3.6.1.4.1.5040.1.2.32.3.1.2.1.6
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtIpWatcher-24VStTzStartMonth 1.3.6.1.4.1.5040.1.2.32.3.1.2.1.7
Month in which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtIpWatcher-24VStartMonth-January(1), wtIpWatcher-24VStartMonth-February(2), wtIpWatcher-24VStartMonth-March(3), wtIpWatcher-24VStartMonth-April(4), wtIpWatcher-24VStartMonth-May(5), wtIpWatcher-24VStartMonth-June(6), wtIpWatcher-24VStartMonth-July(7), wtIpWatcher-24VStartMonth-August(8), wtIpWatcher-24VStartMonth-September(9), wtIpWatcher-24VStartMonth-October(10), wtIpWatcher-24VStartMonth-November(11), wtIpWatcher-24VStartMonth-December(12)  

wtIpWatcher-24VStTzStartMode 1.3.6.1.4.1.5040.1.2.32.3.1.2.1.8
Mode of the day of the week for which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtIpWatcher-24VStartMode-first(1), wtIpWatcher-24VStartMode-second(2), wtIpWatcher-24VStartMode-third(3), wtIpWatcher-24VStartMode-fourth(4), wtIpWatcher-24VStartMode-last(5)  

wtIpWatcher-24VStTzStartWday 1.3.6.1.4.1.5040.1.2.32.3.1.2.1.9
Day of the week on which the change is made from winter time to summer time
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtIpWatcher-24VStartWday-Sunday(1), wtIpWatcher-24VStartWday-Monday(2), wtIpWatcher-24VStartWday-Tuesday(3), wtIpWatcher-24VStartWday-Thursday(4), wtIpWatcher-24VStartWday-Wednesday(5), wtIpWatcher-24VStartWday-Friday(6), wtIpWatcher-24VStartWday-Saturday(7)  

wtIpWatcher-24VStTzStartHrs 1.3.6.1.4.1.5040.1.2.32.3.1.2.1.10
Hour in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcher-24VStTzStartMin 1.3.6.1.4.1.5040.1.2.32.3.1.2.1.11
Minute in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcher-24VStTzStopMonth 1.3.6.1.4.1.5040.1.2.32.3.1.2.1.12
Month in which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtIpWatcher-24VStopMonth-January(1), wtIpWatcher-24VStopMonth-February(2), wtIpWatcher-24VStopMonth-March(3), wtIpWatcher-24VStopMonth-April(4), wtIpWatcher-24VStopMonth-May(5), wtIpWatcher-24VStopMonth-June(6), wtIpWatcher-24VStopMonth-July(7), wtIpWatcher-24VStopMonth-August(8), wtIpWatcher-24VStopMonth-September(9), wtIpWatcher-24VStopMonth-October(10), wtIpWatcher-24VStopMonth-November(11), wtIpWatcher-24VStopMonth-December(12)  

wtIpWatcher-24VStTzStopMode 1.3.6.1.4.1.5040.1.2.32.3.1.2.1.13
Mode of the week day on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtIpWatcher-24VStopMode-first(1), wtIpWatcher-24VStopMode-second(2), wtIpWatcher-24VStopMode-third(3), wtIpWatcher-24VStopMode-fourth(4), wtIpWatcher-24VStopMode-last(5)  

wtIpWatcher-24VStTzStopWday 1.3.6.1.4.1.5040.1.2.32.3.1.2.1.14
Day of the week on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtIpWatcher-24VStopWday-Sunday(1), wtIpWatcher-24VStopWday-Monday(2), wtIpWatcher-24VStopWday-Tuesday(3), wtIpWatcher-24VStopWday-Thursday(4), wtIpWatcher-24VStopWday-Wednesday(5), wtIpWatcher-24VStopWday-Friday(6), wtIpWatcher-24VStopWday-Saturday(7)  

wtIpWatcher-24VStTzStopHrs 1.3.6.1.4.1.5040.1.2.32.3.1.2.1.15
Hour at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcher-24VStTzStopMin 1.3.6.1.4.1.5040.1.2.32.3.1.2.1.16
Minute at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcher-24VTimeServer1 1.3.6.1.4.1.5040.1.2.32.3.1.2.2.1
IP address or name of the 1st time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VTimeServer2 1.3.6.1.4.1.5040.1.2.32.3.1.2.2.2
IP address or name of the 2nd time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VTsEnable 1.3.6.1.4.1.5040.1.2.32.3.1.2.2.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtIpWatcher-24VTsSyncTime 1.3.6.1.4.1.5040.1.2.32.3.1.2.2.4
Daily synchronisation time with the time server (hour: 0-23).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcher-24VClockHrs 1.3.6.1.4.1.5040.1.2.32.3.1.2.3.1
Clock hours taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..23  

wtIpWatcher-24VClockMin 1.3.6.1.4.1.5040.1.2.32.3.1.2.3.2
Clock minutes taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..59  

wtIpWatcher-24VClockDay 1.3.6.1.4.1.5040.1.2.32.3.1.2.3.3
Date: Day of the month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..31  

wtIpWatcher-24VClockMonth 1.3.6.1.4.1.5040.1.2.32.3.1.2.3.4
Date: Month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtIpWatcher-24VClockMonth-January(1), wtIpWatcher-24VClockMonth-February(2), wtIpWatcher-24VClockMonth-March(3), wtIpWatcher-24VClockMonth-April(4), wtIpWatcher-24VClockMonth-May(5), wtIpWatcher-24VClockMonth-June(6), wtIpWatcher-24VClockMonth-July(7), wtIpWatcher-24VClockMonth-August(8), wtIpWatcher-24VClockMonth-September(9), wtIpWatcher-24VClockMonth-October(10), wtIpWatcher-24VClockMonth-November(11), wtIpWatcher-24VClockMonth-December(12)  

wtIpWatcher-24VClockYear 1.3.6.1.4.1.5040.1.2.32.3.1.2.3.5
Date: Year, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtIpWatcher-24VIpAddress 1.3.6.1.4.1.5040.1.2.32.3.1.3.1.1
IP address of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtIpWatcher-24VSubnetMask 1.3.6.1.4.1.5040.1.2.32.3.1.3.1.2
Subnet mask of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtIpWatcher-24VGateway 1.3.6.1.4.1.5040.1.2.32.3.1.3.1.3
Gateway of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtIpWatcher-24VDnsServer1 1.3.6.1.4.1.5040.1.2.32.3.1.3.1.4
IP address of the 1st DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VDnsServer2 1.3.6.1.4.1.5040.1.2.32.3.1.3.1.5
IP address of the 2nd DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAddConfig 1.3.6.1.4.1.5040.1.2.32.3.1.3.1.6
Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP enable Bit 0: BOOTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VHttpPort 1.3.6.1.4.1.5040.1.2.32.3.1.3.2.4
Definition of the standard HTML port (Default: 80).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65534  

wtIpWatcher-24VMailAdName 1.3.6.1.4.1.5040.1.2.32.3.1.3.3.1
Device name for mail administration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VMailReply 1.3.6.1.4.1.5040.1.2.32.3.1.3.3.2
Reply address for the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VMailServer 1.3.6.1.4.1.5040.1.2.32.3.1.3.3.3
Name or IP address of the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VMailEnable 1.3.6.1.4.1.5040.1.2.32.3.1.3.3.4
Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VMailAuthentication 1.3.6.1.4.1.5040.1.2.32.3.1.3.3.5
Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtIpWatcher-24VMailAuthUser 1.3.6.1.4.1.5040.1.2.32.3.1.3.3.6
Name of the user to be authenticated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VMailAuthPassword 1.3.6.1.4.1.5040.1.2.32.3.1.3.3.7
Authentication password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VMailPop3Server 1.3.6.1.4.1.5040.1.2.32.3.1.3.3.8
Name or Ip-address of the POP3 Servers.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VSnmpEnable 1.3.6.1.4.1.5040.1.2.32.3.1.3.4.1
Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VSnmpCommunityStringRead 1.3.6.1.4.1.5040.1.2.32.3.1.3.4.2
Community string read only
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VSnmpCommunityStringReadWrite 1.3.6.1.4.1.5040.1.2.32.3.1.3.4.3
Community string read / write
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VSnmpSystemTrapManagerIP 1.3.6.1.4.1.5040.1.2.32.3.1.3.4.4
Name or IP address of the TCP server which accepts the system trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VSnmpSystemTrapEnable 1.3.6.1.4.1.5040.1.2.32.3.1.3.4.5
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag messages Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtIpWatcher-24VUdpAdminPort 1.3.6.1.4.1.5040.1.2.32.3.1.3.5.1
Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcher-24VUdpEnable 1.3.6.1.4.1.5040.1.2.32.3.1.3.5.2
Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VUdpRemotePort 1.3.6.1.4.1.5040.1.2.32.3.1.3.5.3
Udp remote port setting. If this value is set to zero, the source port read from a request will be used as destination port for the answer. A non zero value forced the destination port to this value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcher-24VSyslogServerIP 1.3.6.1.4.1.5040.1.2.32.3.1.3.7.1
Name or IP address of the Syslog server, which accepts the Syslog messgaes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VSyslogServerPort 1.3.6.1.4.1.5040.1.2.32.3.1.3.7.2
Portnumber of the Syslog servers, default 514.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcher-24VSyslogSystemMessagesEnable 1.3.6.1.4.1.5040.1.2.32.3.1.3.7.3
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtIpWatcher-24VSyslogEnable 1.3.6.1.4.1.5040.1.2.32.3.1.3.7.4
Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VFTPServerIP 1.3.6.1.4.1.5040.1.2.32.3.1.3.8.1
Name or IP address of the FTP server, which accepts the FTP messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VFTPServerControlPort 1.3.6.1.4.1.5040.1.2.32.3.1.3.8.2
Portnumber of the control port of the FTP server, default 21.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcher-24VFTPUserName 1.3.6.1.4.1.5040.1.2.32.3.1.3.8.3
FTP Loggin: user name.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VFTPPassword 1.3.6.1.4.1.5040.1.2.32.3.1.3.8.4
FTP Loggin: user password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VFTPAccount 1.3.6.1.4.1.5040.1.2.32.3.1.3.8.5
FTP Loggin: name of account.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VFTPOption 1.3.6.1.4.1.5040.1.2.32.3.1.3.8.6
Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VFTPEnable 1.3.6.1.4.1.5040.1.2.32.3.1.3.8.7
Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VIpListCount 1.3.6.1.4.1.5040.1.2.32.3.1.3.11.1
Number of Ip addresses.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtIpWatcher-24VIpListIfTable 1.3.6.1.4.1.5040.1.2.32.3.1.3.11.2
Table of inices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtIpWatcher-24VIpListIfEntry

wtIpWatcher-24VIpListIfEntry 1.3.6.1.4.1.5040.1.2.32.3.1.3.11.2.1
Table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtIpWatcher-24VIpListIfEntry  

wtIpWatcher-24VIpListNo 1.3.6.1.4.1.5040.1.2.32.3.1.3.11.2.1.1
List number of this entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..999  

wtIpWatcher-24VIpListTable 1.3.6.1.4.1.5040.1.2.32.3.1.3.11.3
List of ip addresses.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtIpWatcher-24VIpListEntry

wtIpWatcher-24VIpListEntry 1.3.6.1.4.1.5040.1.2.32.3.1.3.11.3.1
List entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtIpWatcher-24VIpListEntry  

wtIpWatcher-24VIpListName 1.3.6.1.4.1.5040.1.2.32.3.1.3.11.3.1.1
Name or IP address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VIpListPort 1.3.6.1.4.1.5040.1.2.32.3.1.3.11.3.1.2
Port number, zero in the case of broadcast or Ping.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcher-24VIpListService 1.3.6.1.4.1.5040.1.2.32.3.1.3.11.3.1.3
Binary coded scan mode, only one mode can be selected at a particular time: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Ping enable Bit 1-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VIpListEnable 1.3.6.1.4.1.5040.1.2.32.3.1.3.11.3.1.4
Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: enabled in Alarm 1 Bit 1: enabled in Alarm 2 Bit 2: enabled in Alarm 3 Bit 3: enabled in Alarm 4 Bit 4-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VIpListAlias 1.3.6.1.4.1.5040.1.2.32.3.1.3.11.3.1.5
Alias Name
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VPowerSupplyEnable 1.3.6.1.4.1.5040.1.2.32.3.1.4.4
Setting this enable bit turns on the intarnal 24V power supply of the outputs. All currents out must not exceed 150mA. At overcurrent condition the power supply will be shut down automatically. To reset the ocvercurrent protection circuit write 1 into wtIpWatcher-24VDiagErrorClear. Internal power supply is a feature of 57655 only. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Power Supply enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmCount 1.3.6.1.4.1.5040.1.2.32.3.1.5.1
Number of independent alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

wtIpWatcher-24VAlarmIfTable 1.3.6.1.4.1.5040.1.2.32.3.1.5.2
List of alarm indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtIpWatcher-24VAlarmIfEntry

wtIpWatcher-24VAlarmIfEntry 1.3.6.1.4.1.5040.1.2.32.3.1.5.2.1
Numbers of the alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtIpWatcher-24VAlarmIfEntry  

wtIpWatcher-24VAlarmNo 1.3.6.1.4.1.5040.1.2.32.3.1.5.2.1.1
Numbers of the alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

wtIpWatcher-24VAlarmTable 1.3.6.1.4.1.5040.1.2.32.3.1.5.3
List of settings depending on the alarm number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtIpWatcher-24VAlarmEntry

wtIpWatcher-24VAlarmEntry 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1
Alarm parameters of the individual alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtIpWatcher-24VAlarmEntry  

wtIpWatcher-24VAlarmInterval 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.5
Send interval for alarm messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmEnable 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.6
Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: UDP enable Bit 3: Send inputs to pending TCP connections Bit 4: TCP Client enable Bit 5: Syslog Messages enable Bit 6-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtIpWatcher-24VAlarmMailAddr 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.7
E-Mail address for sending the alarm mail to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmMailSubject 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.8
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmMailText 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.9
Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmSnmpManagerIP 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.10
IP address of the SNMP Manager to which the Webio device should send SNMP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmSnmpTrapText 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.11
This text appears in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmUdpIpAddr 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.12
IP address of the UDP listener to which the Webio device should send UDP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmUdpPort 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.13
Port number of the UDP listener to which the Webio device should send UDP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtIpWatcher-24VAlarmUdpText 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.14
This text appears in the UDP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmTcpIpAddr 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.15
IP address of the TCP listener to which the Webio device should send TCP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmTcpPort 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.16
Port number of the TCP listener to which the Webio device should send TCP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtIpWatcher-24VAlarmTcpText 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.17
This text appears in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmSyslogIpAddr 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.18
IP address of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmSyslogPort 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.19
Port number of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtIpWatcher-24VAlarmSyslogText 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.20
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmFtpDataPort 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.21
Local data port: 1..65535 or AUTO: the next free port will be assigned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmFtpFileName 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.22
Name of the file including path informations.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmFtpText 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.23
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmFtpOption 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.24
Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtIpWatcher-24VAlarmTimerCron 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.25
This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmMailReleaseSubject 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.26
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmMailReleaseText 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.27
Release Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmSnmpTrapReleaseText 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.28
This text appears in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmUdpReleaseText 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.29
This text appears in the UDP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmTcpReleaseText 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.30
This text appears in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmSyslogReleaseText 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.31
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmFtpReleaseText 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.32
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmName 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.33
Name of the alarm.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmGlobalEnable 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.34
Binary coded alarm activation: Die OCTETS werden bitweise interpretiert. Bit 0 entspricht dem LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : Alarm enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmCounterClear 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.35
Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : Counter clear on Alarm acknowledge Bit 0 : Counter clear on Alarm send
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmAckEnable 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.36
Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : Software acknowledge enable Bit 0 : Hardware acknowledge enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmAckPort 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.37
Number of the input, which clears the alarm (1-6).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcher-24VAlarmSetPort 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.38
Number of the output, which will be set by this alarm (1-6). The configuration of pulse mode and polarity defined in the port output section is used.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcher-24VAlarmMailTrgClearSubject 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.39
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmMailTrgClearText 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.40
Alarm mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmSnmpTrapTrgClearText 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.41
This text appears in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmUdpTrgClearText 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.42
This text appears in the UDP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmTcpTrgClearText 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.43
This text appears in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmSyslogTrgClearText 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.44
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmFtpTrgClearText 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.45
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmMailTrapTxEnable 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.46
Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmSnmpTrapTrapTxEnable 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.47
Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmUdpTrapTxEnable 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.48
Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmTcpTrapTxEnable 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.49
Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmSyslogTrapTxEnable 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.50
Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmFtpTrapTxEnable 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.51
Binary coded options: The OCTETS are interpreted bit-by-bit. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 4-7: unused Bit 3 : Alarm OFF message enable Bit 2 : Trigger OFF message enable Bit 1 : Re-Trigger message enable Bit 0 : Alarm ON message enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VAlarmTriggerCount 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.52
Alarm will be send if the trigger condition occours TriggerCount times.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcher-24VAlarmPollingRate 1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.53
Time in seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcher-24VInputPortTable 1.3.6.1.4.1.5040.1.2.32.3.2.1
List of settings depending on the input number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtIpWatcher-24VInputPortEntry

wtIpWatcher-24VInputPortEntry 1.3.6.1.4.1.5040.1.2.32.3.2.1.1
Input parameter for the individual inputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtIpWatcher-24VInputPortEntry  

wtIpWatcher-24VPortInputName 1.3.6.1.4.1.5040.1.2.32.3.2.1.1.1
Name of the input.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VPortInputText 1.3.6.1.4.1.5040.1.2.32.3.2.1.1.2
Description of the input.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VPortInputFilter 1.3.6.1.4.1.5040.1.2.32.3.2.1.1.4
Pulses with a duration shorter than here specified (duration in 1/1000 sec), are ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcher-24VOutputPortTable 1.3.6.1.4.1.5040.1.2.32.3.2.2
List of settings depending on the output number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtIpWatcher-24VOutputPortEntry

wtIpWatcher-24VOutputPortEntry 1.3.6.1.4.1.5040.1.2.32.3.2.2.1
Output parameters of the individual outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtIpWatcher-24VOutputPortEntry  

wtIpWatcher-24VPortOutputName 1.3.6.1.4.1.5040.1.2.32.3.2.2.1.1
Name of the output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VPortOutputText 1.3.6.1.4.1.5040.1.2.32.3.2.2.1.2
Description of the output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VPortPulseDuration 1.3.6.1.4.1.5040.1.2.32.3.2.2.1.9
Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcher-24VPortPulsePolarity 1.3.6.1.4.1.5040.1.2.32.3.2.2.1.10
This value defines the polarity of the output pulse, if wtIpWatcher-24VPortPulseDuration is not set to zero. After the pulse is finished, the output switches back to the opposite state. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtIpWatcher-24VMfName 1.3.6.1.4.1.5040.1.2.32.3.3.1
Manufacturer company name
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VMfAddr 1.3.6.1.4.1.5040.1.2.32.3.3.2
Manufacturer address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VMfHotline 1.3.6.1.4.1.5040.1.2.32.3.3.3
Manufacturer hotline.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VMfInternet 1.3.6.1.4.1.5040.1.2.32.3.3.4
Manufacturer Internet address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VMfDeviceTyp 1.3.6.1.4.1.5040.1.2.32.3.3.5
Manufacturer device name (model number).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VDiagErrorCount 1.3.6.1.4.1.5040.1.2.32.4.1
Number of entries in the error memory.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtIpWatcher-24VDiagBinaryError 1.3.6.1.4.1.5040.1.2.32.4.2
Error causes coded bit-by-bit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VDiagErrorIndex 1.3.6.1.4.1.5040.1.2.32.4.3
The value of this variable is used as an index to read an error massege from wtIpWatcher-24VDiagErrorMessage. Errors are numbered from 1 to wtIpWatcher-24VDiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtIpWatcher-24VDiagErrorMessage.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtIpWatcher-24VDiagErrorMessage 1.3.6.1.4.1.5040.1.2.32.4.4
Using wtIpWatcher-24VDiagErrorIndex as an index, the appropriate message is available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtIpWatcher-24VDiagErrorClear 1.3.6.1.4.1.5040.1.2.32.4.5
Writing 1 into this variable clears all diagnosis messages.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER  

wtIpWatcher-24VAlert1 41
This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert2 42
This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert3 43
This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert4 44
This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert5 45
This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert6 46
This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert7 47
This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert8 48
This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert9 49
This SNMP trap is generated when Alarm 9 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert10 50
This SNMP trap is generated when Alarm 10 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert11 51
This SNMP trap is generated when Alarm 11 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert12 52
This SNMP trap is generated when Alarm 12 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert13 71
This SNMP trap is generated when Alarm 1 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert14 72
This SNMP trap is generated when Alarm 2 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert15 73
This SNMP trap is generated when Alarm 3 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert16 74
This SNMP trap is generated when Alarm 4 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert17 75
This SNMP trap is generated when Alarm 5 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert18 76
This SNMP trap is generated when Alarm 6 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert19 77
This SNMP trap is generated when Alarm 7 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert20 78
This SNMP trap is generated when Alarm 8 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert21 79
This SNMP trap is generated when Alarm 9 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert22 80
This SNMP trap is generated when Alarm 10 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert23 81
This SNMP trap is generated when Alarm 11 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert24 82
This SNMP trap is generated when Alarm 12 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert25 91
This SNMP trap is generated when the trigger of the Alarm 1 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert26 92
This SNMP trap is generated when the trigger of the Alarm 2 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert27 93
This SNMP trap is generated when the trigger of the Alarm 3 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert28 94
This SNMP trap is generated when the trigger of the Alarm 4 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert29 95
This SNMP trap is generated when the trigger of the Alarm 5 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert30 96
This SNMP trap is generated when the trigger of the Alarm 6 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert31 97
This SNMP trap is generated when the trigger of the Alarm 7 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert32 98
This SNMP trap is generated when the trigger of the Alarm 8 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert33 99
This SNMP trap is generated when the trigger of the Alarm 9 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert34 100
This SNMP trap is generated when the trigger of the Alarm 10 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert35 101
This SNMP trap is generated when the trigger of the Alarm 11 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlert36 102
This SNMP trap is generated when the trigger of the Alarm 12 was released, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtIpWatcher-24VAlertDiag 110
This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtTrapReceiver2x2Inputs 1.3.6.1.4.1.5040.1.2.33.1.1
Number of idependent inputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtTrapReceiver2x2Outputs 1.3.6.1.4.1.5040.1.2.33.1.2
Number of idependent outputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtTrapReceiver2x2InputTable 1.3.6.1.4.1.5040.1.2.33.1.3
List of input indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtTrapReceiver2x2InputEntry

wtTrapReceiver2x2InputEntry 1.3.6.1.4.1.5040.1.2.33.1.3.1
Number of the inputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtTrapReceiver2x2InputEntry  

wtTrapReceiver2x2InputNo 1.3.6.1.4.1.5040.1.2.33.1.3.1.1
Index numbers of the inputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtTrapReceiver2x2InputState 1.3.6.1.4.1.5040.1.2.33.1.3.1.4
Value of a single input bit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtTrapReceiver2x2InputState-OFF(0), wtTrapReceiver2x2InputState-ON(1)  

wtTrapReceiver2x2InputValue 1.3.6.1.4.1.5040.1.2.33.1.4
This variable is used to read the inputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital outputs 0-1
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtTrapReceiver2x2OutputTable 1.3.6.1.4.1.5040.1.2.33.1.5
List of output indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtTrapReceiver2x2OutputEntry

wtTrapReceiver2x2OutputEntry 1.3.6.1.4.1.5040.1.2.33.1.5.1
Number of the outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtTrapReceiver2x2OutputEntry  

wtTrapReceiver2x2OutputNo 1.3.6.1.4.1.5040.1.2.33.1.5.1.1
Output number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtTrapReceiver2x2OutputState 1.3.6.1.4.1.5040.1.2.33.1.5.1.2
Value of a single output bit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtTrapReceiver2x2OutputState-OFF(0), wtTrapReceiver2x2OutputState-ON(1)  

wtTrapReceiver2x2OutputValue 1.3.6.1.4.1.5040.1.2.33.1.6
This variable is used to read the outputs of the digital I/O port. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Digital outputs 0-1 Bit 2-7: ungenutzt
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtTrapReceiver2x2ActionOutputTable 1.3.6.1.4.1.5040.1.2.33.1.8
List of alarm indices..
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtTrapReceiver2x2ActionOutputEntry

wtTrapReceiver2x2ActionOutputEntry 1.3.6.1.4.1.5040.1.2.33.1.8.1
Index reference.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtTrapReceiver2x2ActionOutputEntry  

wtTrapReceiver2x2ActionOutputState 1.3.6.1.4.1.5040.1.2.33.1.8.1.1
State of the alarm.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtTrapReceiver2x2ActionOutputState-OFF(0), wtTrapReceiver2x2ActionOutputState-ON(1)  

wtTrapReceiver2x2ActionTriggerState 1.3.6.1.4.1.5040.1.2.33.1.8.1.2
State of the trigger condition.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtTrapReceiver2x2ActionTriggerState-OFF(0), wtTrapReceiver2x2ActionTriggerState-ON(1)  

wtTrapReceiver2x2SystemTimerTable 1.3.6.1.4.1.5040.1.2.33.1.9
List of system timer.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtTrapReceiver2x2SystemTimerEntry

wtTrapReceiver2x2SystemTimerEntry 1.3.6.1.4.1.5040.1.2.33.1.9.1
Number of the system timer.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtTrapReceiver2x2SystemTimerEntry  

wtTrapReceiver2x2SystemTimerNo 1.3.6.1.4.1.5040.1.2.33.1.9.1.1
Index number of the system timer.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtTrapReceiver2x2ButtonTable 1.3.6.1.4.1.5040.1.2.33.1.10
List of buttons.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtTrapReceiver2x2ButtonEntry

wtTrapReceiver2x2ButtonEntry 1.3.6.1.4.1.5040.1.2.33.1.10.1
Number of the button.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtTrapReceiver2x2ButtonEntry  

wtTrapReceiver2x2ButtonNo 1.3.6.1.4.1.5040.1.2.33.1.10.1.1
Index numder of the button.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtTrapReceiver2x2SessCntrlPassword 1.3.6.1.4.1.5040.1.2.33.2.1
Entering this password opens a session which is ended by writing a 1 to wtTrapReceiver2x2SessCntrlLogout. When read this variable provides a string of length zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2SessCntrlConfigMode 1.3.6.1.4.1.5040.1.2.33.2.2
When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtTrapReceiver2x2SessCntrl-NoSession(0), wtTrapReceiver2x2SessCntrl-Session(1)  

wtTrapReceiver2x2SessCntrlLogout 1.3.6.1.4.1.5040.1.2.33.2.3
If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtTrapReceiver2x2SessCntrlAdminPassword 1.3.6.1.4.1.5040.1.2.33.2.4
This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2SessCntrlConfigPassword 1.3.6.1.4.1.5040.1.2.33.2.5
This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2DeviceName 1.3.6.1.4.1.5040.1.2.33.3.1.1.1
Name of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2DeviceText 1.3.6.1.4.1.5040.1.2.33.3.1.1.2
Description of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2DeviceLocation 1.3.6.1.4.1.5040.1.2.33.3.1.1.3
Description of the location of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2DeviceContact 1.3.6.1.4.1.5040.1.2.33.3.1.1.4
Contact address of the system operator of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2TzOffsetHrs 1.3.6.1.4.1.5040.1.2.33.3.1.2.1.1
Offset hours for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtTrapReceiver2x2TzOffsetMin 1.3.6.1.4.1.5040.1.2.33.3.1.2.1.2
Offset minutes for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtTrapReceiver2x2TzEnable 1.3.6.1.4.1.5040.1.2.33.3.1.2.1.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtTrapReceiver2x2StTzOffsetHrs 1.3.6.1.4.1.5040.1.2.33.3.1.2.1.4
Offset hours of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtTrapReceiver2x2StTzOffsetMin 1.3.6.1.4.1.5040.1.2.33.3.1.2.1.5
Offset minutes of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtTrapReceiver2x2StTzEnable 1.3.6.1.4.1.5040.1.2.33.3.1.2.1.6
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtTrapReceiver2x2StTzStartMonth 1.3.6.1.4.1.5040.1.2.33.3.1.2.1.7
Month in which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtTrapReceiver2x2StartMonth-January(1), wtTrapReceiver2x2StartMonth-February(2), wtTrapReceiver2x2StartMonth-March(3), wtTrapReceiver2x2StartMonth-April(4), wtTrapReceiver2x2StartMonth-May(5), wtTrapReceiver2x2StartMonth-June(6), wtTrapReceiver2x2StartMonth-July(7), wtTrapReceiver2x2StartMonth-August(8), wtTrapReceiver2x2StartMonth-September(9), wtTrapReceiver2x2StartMonth-October(10), wtTrapReceiver2x2StartMonth-November(11), wtTrapReceiver2x2StartMonth-December(12)  

wtTrapReceiver2x2StTzStartMode 1.3.6.1.4.1.5040.1.2.33.3.1.2.1.8
Mode of the day of the week for which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtTrapReceiver2x2StartMode-first(1), wtTrapReceiver2x2StartMode-second(2), wtTrapReceiver2x2StartMode-third(3), wtTrapReceiver2x2StartMode-fourth(4), wtTrapReceiver2x2StartMode-last(5)  

wtTrapReceiver2x2StTzStartWday 1.3.6.1.4.1.5040.1.2.33.3.1.2.1.9
Day of the week on which the change is made from winter time to summer time
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtTrapReceiver2x2StartWday-Sunday(1), wtTrapReceiver2x2StartWday-Monday(2), wtTrapReceiver2x2StartWday-Tuesday(3), wtTrapReceiver2x2StartWday-Thursday(4), wtTrapReceiver2x2StartWday-Wednesday(5), wtTrapReceiver2x2StartWday-Friday(6), wtTrapReceiver2x2StartWday-Saturday(7)  

wtTrapReceiver2x2StTzStartHrs 1.3.6.1.4.1.5040.1.2.33.3.1.2.1.10
Hour in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtTrapReceiver2x2StTzStartMin 1.3.6.1.4.1.5040.1.2.33.3.1.2.1.11
Minute in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtTrapReceiver2x2StTzStopMonth 1.3.6.1.4.1.5040.1.2.33.3.1.2.1.12
Month in which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtTrapReceiver2x2StopMonth-January(1), wtTrapReceiver2x2StopMonth-February(2), wtTrapReceiver2x2StopMonth-March(3), wtTrapReceiver2x2StopMonth-April(4), wtTrapReceiver2x2StopMonth-May(5), wtTrapReceiver2x2StopMonth-June(6), wtTrapReceiver2x2StopMonth-July(7), wtTrapReceiver2x2StopMonth-August(8), wtTrapReceiver2x2StopMonth-September(9), wtTrapReceiver2x2StopMonth-October(10), wtTrapReceiver2x2StopMonth-November(11), wtTrapReceiver2x2StopMonth-December(12)  

wtTrapReceiver2x2StTzStopMode 1.3.6.1.4.1.5040.1.2.33.3.1.2.1.13
Mode of the week day on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtTrapReceiver2x2StopMode-first(1), wtTrapReceiver2x2StopMode-second(2), wtTrapReceiver2x2StopMode-third(3), wtTrapReceiver2x2StopMode-fourth(4), wtTrapReceiver2x2StopMode-last(5)  

wtTrapReceiver2x2StTzStopWday 1.3.6.1.4.1.5040.1.2.33.3.1.2.1.14
Day of the week on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtTrapReceiver2x2StopWday-Sunday(1), wtTrapReceiver2x2StopWday-Monday(2), wtTrapReceiver2x2StopWday-Tuesday(3), wtTrapReceiver2x2StopWday-Thursday(4), wtTrapReceiver2x2StopWday-Wednesday(5), wtTrapReceiver2x2StopWday-Friday(6), wtTrapReceiver2x2StopWday-Saturday(7)  

wtTrapReceiver2x2StTzStopHrs 1.3.6.1.4.1.5040.1.2.33.3.1.2.1.15
Hour at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtTrapReceiver2x2StTzStopMin 1.3.6.1.4.1.5040.1.2.33.3.1.2.1.16
Minute at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtTrapReceiver2x2TimeServer1 1.3.6.1.4.1.5040.1.2.33.3.1.2.2.1
IP address or name of the 1st time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2TimeServer2 1.3.6.1.4.1.5040.1.2.33.3.1.2.2.2
IP address or name of the 2nd time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2TsEnable 1.3.6.1.4.1.5040.1.2.33.3.1.2.2.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtTrapReceiver2x2TsSyncTime 1.3.6.1.4.1.5040.1.2.33.3.1.2.2.4
Daily synchronisation time with the time server (hour: 0-23).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtTrapReceiver2x2ClockHrs 1.3.6.1.4.1.5040.1.2.33.3.1.2.3.1
Clock hours taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..23  

wtTrapReceiver2x2ClockMin 1.3.6.1.4.1.5040.1.2.33.3.1.2.3.2
Clock minutes taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..59  

wtTrapReceiver2x2ClockDay 1.3.6.1.4.1.5040.1.2.33.3.1.2.3.3
Date: Day of the month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..31  

wtTrapReceiver2x2ClockMonth 1.3.6.1.4.1.5040.1.2.33.3.1.2.3.4
Date: Month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtTrapReceiver2x2ClockMonth-January(1), wtTrapReceiver2x2ClockMonth-February(2), wtTrapReceiver2x2ClockMonth-March(3), wtTrapReceiver2x2ClockMonth-April(4), wtTrapReceiver2x2ClockMonth-May(5), wtTrapReceiver2x2ClockMonth-June(6), wtTrapReceiver2x2ClockMonth-July(7), wtTrapReceiver2x2ClockMonth-August(8), wtTrapReceiver2x2ClockMonth-September(9), wtTrapReceiver2x2ClockMonth-October(10), wtTrapReceiver2x2ClockMonth-November(11), wtTrapReceiver2x2ClockMonth-December(12)  

wtTrapReceiver2x2ClockYear 1.3.6.1.4.1.5040.1.2.33.3.1.2.3.5
Date: Year, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtTrapReceiver2x2IpAddress 1.3.6.1.4.1.5040.1.2.33.3.1.3.1.1
IP address of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtTrapReceiver2x2SubnetMask 1.3.6.1.4.1.5040.1.2.33.3.1.3.1.2
Subnet mask of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtTrapReceiver2x2Gateway 1.3.6.1.4.1.5040.1.2.33.3.1.3.1.3
Gateway of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtTrapReceiver2x2DnsServer1 1.3.6.1.4.1.5040.1.2.33.3.1.3.1.4
IP address of the 1st DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2DnsServer2 1.3.6.1.4.1.5040.1.2.33.3.1.3.1.5
IP address of the 2nd DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2AddConfig 1.3.6.1.4.1.5040.1.2.33.3.1.3.1.6
Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP enable Bit 0: BOOTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2HttpPort 1.3.6.1.4.1.5040.1.2.33.3.1.3.2.4
Definition of the standard HTML port (Default: 80).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65534  

wtTrapReceiver2x2MailAdName 1.3.6.1.4.1.5040.1.2.33.3.1.3.3.1
Device name for mail administration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2MailReply 1.3.6.1.4.1.5040.1.2.33.3.1.3.3.2
Reply address for the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2MailServer 1.3.6.1.4.1.5040.1.2.33.3.1.3.3.3
Name or IP address of the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2MailEnable 1.3.6.1.4.1.5040.1.2.33.3.1.3.3.4
Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2MailAuthentication 1.3.6.1.4.1.5040.1.2.33.3.1.3.3.5
Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtTrapReceiver2x2MailAuthUser 1.3.6.1.4.1.5040.1.2.33.3.1.3.3.6
Name of the user to be authenticated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2MailAuthPassword 1.3.6.1.4.1.5040.1.2.33.3.1.3.3.7
Authentication password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2MailPop3Server 1.3.6.1.4.1.5040.1.2.33.3.1.3.3.8
Name or Ip-address of the POP3 Servers.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2SnmpEnable 1.3.6.1.4.1.5040.1.2.33.3.1.3.4.1
Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2SnmpCommunityStringRead 1.3.6.1.4.1.5040.1.2.33.3.1.3.4.2
Community string read only
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2SnmpCommunityStringReadWrite 1.3.6.1.4.1.5040.1.2.33.3.1.3.4.3
Community string read / write
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2SnmpSystemTrapManagerIP 1.3.6.1.4.1.5040.1.2.33.3.1.3.4.4
Name or IP address of the TCP server which accepts the system trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2SnmpSystemTrapEnable 1.3.6.1.4.1.5040.1.2.33.3.1.3.4.5
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag messages Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtTrapReceiver2x2UdpAdminPort 1.3.6.1.4.1.5040.1.2.33.3.1.3.5.1
Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtTrapReceiver2x2UdpEnable 1.3.6.1.4.1.5040.1.2.33.3.1.3.5.2
Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2UdpRemotePort 1.3.6.1.4.1.5040.1.2.33.3.1.3.5.3
Udp remote port setting. If this value is set to zero, the source port read from a request will be used as destination port for the answer. A non zero value forced the destination port to this value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtTrapReceiver2x2SyslogServerIP 1.3.6.1.4.1.5040.1.2.33.3.1.3.7.1
Name or IP address of the Syslog server, which accepts the Syslog messgaes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2SyslogServerPort 1.3.6.1.4.1.5040.1.2.33.3.1.3.7.2
Portnumber of the Syslog servers, default 514.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtTrapReceiver2x2SyslogSystemMessagesEnable 1.3.6.1.4.1.5040.1.2.33.3.1.3.7.3
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtTrapReceiver2x2SyslogEnable 1.3.6.1.4.1.5040.1.2.33.3.1.3.7.4
Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2FTPServerIP 1.3.6.1.4.1.5040.1.2.33.3.1.3.8.1
Name or IP address of the FTP server, which accepts the FTP messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2FTPServerControlPort 1.3.6.1.4.1.5040.1.2.33.3.1.3.8.2
Portnumber of the control port of the FTP server, default 21.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtTrapReceiver2x2FTPUserName 1.3.6.1.4.1.5040.1.2.33.3.1.3.8.3
FTP Loggin: user name.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2FTPPassword 1.3.6.1.4.1.5040.1.2.33.3.1.3.8.4
FTP Loggin: user password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2FTPAccount 1.3.6.1.4.1.5040.1.2.33.3.1.3.8.5
FTP Loggin: name of account.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2FTPOption 1.3.6.1.4.1.5040.1.2.33.3.1.3.8.6
Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2FTPEnable 1.3.6.1.4.1.5040.1.2.33.3.1.3.8.7
Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2WatchListCount 1.3.6.1.4.1.5040.1.2.33.3.1.6.1.1
Number of Ip addresses.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtTrapReceiver2x2WatchListIfTable 1.3.6.1.4.1.5040.1.2.33.3.1.6.1.2
Table of inices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtTrapReceiver2x2WatchListIfEntry

wtTrapReceiver2x2WatchListIfEntry 1.3.6.1.4.1.5040.1.2.33.3.1.6.1.2.1
Table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtTrapReceiver2x2WatchListIfEntry  

wtTrapReceiver2x2WatchListNo 1.3.6.1.4.1.5040.1.2.33.3.1.6.1.2.1.1
List number of this entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..999  

wtTrapReceiver2x2WatchListTable 1.3.6.1.4.1.5040.1.2.33.3.1.6.1.3
List of ip addresses.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtTrapReceiver2x2WatchListEntry

wtTrapReceiver2x2WatchListEntry 1.3.6.1.4.1.5040.1.2.33.3.1.6.1.3.1
List entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtTrapReceiver2x2WatchListEntry  

wtTrapReceiver2x2WatchListName 1.3.6.1.4.1.5040.1.2.33.3.1.6.1.3.1.1
Name or IP address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2WatchListPort 1.3.6.1.4.1.5040.1.2.33.3.1.6.1.3.1.2
Port number, zero in the case of broadcast or Ping.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtTrapReceiver2x2WatchListService 1.3.6.1.4.1.5040.1.2.33.3.1.6.1.3.1.3
Binary coded scan mode, only one mode can be selected at a particular time: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: unused Bit 1: unused Bit 2: SNMP Trap reveive enable Bit 3: Syslog receive enable Bit 4-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2WatchListEnable 1.3.6.1.4.1.5040.1.2.33.3.1.6.1.3.1.4
Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: Bit 0: enabled in Report 9 Bit 1: enabled in Report 10 Bit 2: enabled in Report 11 Bit 3: enabled in Report 12 Bit 4-7: unused Octet 4: Bit 0: enabled in Report 1 Bit 1: enabled in Report 2 Bit 2: enabled in Report 3 Bit 3: enabled in Report 4 Bit 4: enabled in Report 5 Bit 5: enabled in Report 6 Bit 6: enabled in Report 7 Bit 7: enabled in Report 8
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2WatchListAlias 1.3.6.1.4.1.5040.1.2.33.3.1.6.1.3.1.5
Alias Name
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2WatchListTrapNo 1.3.6.1.4.1.5040.1.2.33.3.1.6.1.3.1.6
SNMP Trap No: this filter is only active, if SNMP Trap reveive enable in wtTrapReceiver2x2WatchListService is set.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtTrapReceiver2x2WatchListTrapNo-ColdStart(0), wtTrapReceiver2x2WatchListTrapNo-WarmStart(1), wtTrapReceiver2x2WatchListTrapNo-LinkDown(2), wtTrapReceiver2x2WatchListTrapNo-LinkUp(3), wtTrapReceiver2x2WatchListTrapNo-AuthFailure(4), wtTrapReceiver2x2WatchListTrapNo-EPGneighborLoss(5), wtTrapReceiver2x2WatchListTrapNo-EnterpriseSpecific(6), wtTrapReceiver2x2WatchListTrapNo-WildCard(7)  

wtTrapReceiver2x2WatchListSpecificNo 1.3.6.1.4.1.5040.1.2.33.3.1.6.1.3.1.7
SNMP Specific No: this filter is only active, if SNMP Trap reveive enable in wtTrapReceiver2x2WatchListService is set.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtTrapReceiver2x2WatchListFacility 1.3.6.1.4.1.5040.1.2.33.3.1.6.1.3.1.8
Syslog message level Facility: this filter is only active, if Syslog receive enable in wtTrapReceiver2x2WatchListService is set.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtTrapReceiver2x2WatchListFacility-Emergency(0), wtTrapReceiver2x2WatchListFacility-Alert(1), wtTrapReceiver2x2WatchListFacility-Critical(2), wtTrapReceiver2x2WatchListFacility-Error(3), wtTrapReceiver2x2WatchListFacility-Warning(4), wtTrapReceiver2x2WatchListFacility-Notice(5), wtTrapReceiver2x2WatchListFacility-Informational(6), wtTrapReceiver2x2WatchListFacility-Debug(7), wtTrapReceiver2x2WatchListFacility-WildCard(8)  

wtTrapReceiver2x2WatchListSeverity 1.3.6.1.4.1.5040.1.2.33.3.1.6.1.3.1.9
Syslog message level Severity: this filter is only active, if Syslog receive enable in wtTrapReceiver2x2WatchListService is set.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtTrapReceiver2x2WatchListSeverity-kernel-messages(0), wtTrapReceiver2x2WatchListSeverity-user-level-messages(1), wtTrapReceiver2x2WatchListSeverity-mail-system(2), wtTrapReceiver2x2WatchListSeverity-system-daemons(3), wtTrapReceiver2x2WatchListSeverity-security-authorization-messages(4), wtTrapReceiver2x2WatchListSeverity-messages-generated-internaly-by-syslogd(5), wtTrapReceiver2x2WatchListSeverity-line-printer-subsystem(6), wtTrapReceiver2x2WatchListSeverity-network-news-subsystem(7), wtTrapReceiver2x2WatchListSeverity-UUCP-subsystem(8), wtTrapReceiver2x2WatchListSeverity-clock-daemon(9), wtTrapReceiver2x2WatchListSeverity-security-authorization-messages-private(10), wtTrapReceiver2x2WatchListSeverity-FTP-daemon(11), wtTrapReceiver2x2WatchListSeverity-NTP-subsystem(12), wtTrapReceiver2x2WatchListSeverity-log-audit(13), wtTrapReceiver2x2WatchListSeverity-log-alert(14), wtTrapReceiver2x2WatchListSeverity-clock-daemon-15(15), wtTrapReceiver2x2WatchListSeverity-local0(16), wtTrapReceiver2x2WatchListSeverity-local1(17), wtTrapReceiver2x2WatchListSeverity-local2(18), wtTrapReceiver2x2WatchListSeverity-local3(19), wtTrapReceiver2x2WatchListSeverity-local4(20), wtTrapReceiver2x2WatchListSeverity-local5(21), wtTrapReceiver2x2WatchListSeverity-local6(22), wtTrapReceiver2x2WatchListSeverity-local7(23), wtTrapReceiver2x2WatchListSeverity-WildCard(24)  

wtTrapReceiver2x2PowerSupplyEnable 1.3.6.1.4.1.5040.1.2.33.3.1.4.4
Setting this enable bit turns on the intarnal 24V power supply of the outputs. All currents out must not exceed 150mA. At overcurrent condition the power supply will be shut down automatically. To reset the ocvercurrent protection circuit write 1 into wtTrapReceiver2x2DiagErrorClear. Internal power supply is a feature of 57655 only. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Power Supply enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2ActionCount 1.3.6.1.4.1.5040.1.2.33.3.1.5.1
Number of independent alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

wtTrapReceiver2x2ActionIfTable 1.3.6.1.4.1.5040.1.2.33.3.1.5.2
List of alarm indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtTrapReceiver2x2ActionIfEntry

wtTrapReceiver2x2ActionIfEntry 1.3.6.1.4.1.5040.1.2.33.3.1.5.2.1
Numbers of the alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtTrapReceiver2x2ActionIfEntry  

wtTrapReceiver2x2ActionNo 1.3.6.1.4.1.5040.1.2.33.3.1.5.2.1.1
Numbers of the alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

wtTrapReceiver2x2ActionTable 1.3.6.1.4.1.5040.1.2.33.3.1.5.3
List of settings depending on the alarm number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtTrapReceiver2x2ActionEntry

wtTrapReceiver2x2ActionEntry 1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1
Action parameters of the individual alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtTrapReceiver2x2ActionEntry  

wtTrapReceiver2x2ActionInputTrigger 1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.1
This variable allows setting of individual input trigger conditions. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. The four OCTETS contain the mask which determines which of the inputs are to be considered (corresponding bit = 1) and which inputs are to ignore (corresponding bit = 0): OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0: Input 0 falling edge Bit 1: Input 0 rising edge Bit 2: Input 1 falling edge Bit 3: Input 1 rising edge Bit 4-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(12)  

wtTrapReceiver2x2ActionInterval 1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.5
Send interval for alarm messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2ActionEnable 1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.6
Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: UDP enable Bit 3: Send inputs to pending TCP connections Bit 4: TCP Client enable Bit 5: Syslog Messages enable Bit 6-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtTrapReceiver2x2ActionMailAddr 1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.7
E-Mail address for sending the alarm mail to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2ActionMailSubject 1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.8
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2ActionMailText 1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.9
Action mail text: States of the Webio device can be included by using special tags. Please refer to the respective Webio manual
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2ActionSnmpManagerIP 1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.10
IP address of the SNMP Manager to which the Webio device should send SNMP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2ActionSnmpTrapText 1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.11
This text appears in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2ActionUdpIpAddr 1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.12
IP address of the UDP listener to which the Webio device should send UDP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2ActionUdpPort 1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.13
Port number of the UDP listener to which the Webio device should send UDP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtTrapReceiver2x2ActionUdpText 1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.14
This text appears in the UDP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2ActionTcpIpAddr 1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.15
IP address of the TCP listener to which the Webio device should send TCP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2ActionTcpPort 1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.16
Port number of the TCP listener to which the Webio device should send TCP traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtTrapReceiver2x2ActionTcpText 1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.17
This text appears in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2ActionSyslogIpAddr 1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.18
IP address of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2ActionSyslogPort 1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.19
Port number of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtTrapReceiver2x2ActionSyslogText 1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.20
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2ActionFtpDataPort 1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.21
Local data port: 1..65535 or AUTO: the next free port will be assigned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2ActionFtpFileName 1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.22
Name of the file including path informations.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2ActionFtpText 1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.23
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2ActionFtpOption 1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.24
Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtTrapReceiver2x2ActionTimerCron 1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.25
This entry contains 10 space or tab seperated text fields defining a time window for sending time triggered messages. 2 CRON time for start time and stop time are defined as follows: Start time: field 1: Minutes Range 0-59 3. Hours Range 0-23, 0 is midnight 5: Day of month Range 1-31 7: Month Range 1-12 9: Weekday Range 0-6, 0 is sunday Stop time: field 2: Minutes Range 0-59 4. Hours Range 0-23, 0 is midnight 6: Day of month Range 1-31 8: Month Range 1-12 10: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2ActionName 1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.33
Name of the alarm.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2ActionGlobalEnable 1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.34
Binary coded alarm activation: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : Action enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2ActionSystemTimerTrigger 1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.55
Binary coded system timer activation: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0: System Timer 1 enable Bit 1: System Timer 2 enable Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtTrapReceiver2x2ActionSystemButtonTrigger 1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.56
Binary coded button activation: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0: Button 1 enable Bit 1: Button 2 enable Bit 2: Button 3 enable Bit 3: Button 4 enable Bit 3: Button 5 enable Bit 3: Button 6 enable Bit 3: Button 7 enable Bit 3: Button 8 enable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtTrapReceiver2x2ActionOutputAction 1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.57
This variable allows setting of individual output. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. The first four OCTETS contain the mask which determines which of the outputs are to be considered (corresponding bit = 1) and which outputs are to ignore (corresponding bit = 0): OCTET 1 : unused OCTET 2 : unused OCTET 3 : unused OCTET 4, Bit 0-1: Mask for digital outputs 0-1 OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs should assume: OCTET 5 : unused OCTET 6 : unused OCTET 7 : unused OCTET 8, Bit 0-1: Level of digital outputs 0-1 OCTETS 9-12 contain the TOOGLE bit (1=ON, 0=OFF). outputs masked with the TOGGLE bit trigger change their state on every action. Settings in OCTET 5-9 are then unused: OCTET 9: unused OCTET 10: unused OCTET 11: unused OCTET 12, Bit 0-1: TOGGLE bits of digital outputs 0-1
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(12)  

wtTrapReceiver2x2SystemTimerPortTable 1.3.6.1.4.1.5040.1.2.33.3.1.6.2.1
List of settings depending on the SystemTimer number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtTrapReceiver2x2SystemTimerPortEntry

wtTrapReceiver2x2SystemTimerPortEntry 1.3.6.1.4.1.5040.1.2.33.3.1.6.2.1.1
SystemTimer parameter for the individual SystemTimer.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtTrapReceiver2x2SystemTimerPortEntry  

wtTrapReceiver2x2PortSystemTimerEnable 1.3.6.1.4.1.5040.1.2.33.3.1.6.2.1.1.1
Binary coded SystemTimer enable: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: ungenutzt OCTET 2: ungenutzt OCTET 3: ungenutzt OCTET 4, Bit 1-7: ungenutzt Bit 0 : SystemTimer enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2PortSystemTimerName 1.3.6.1.4.1.5040.1.2.33.3.1.6.2.1.1.2
Name of the SystemTimer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2PortSystemTimerCron 1.3.6.1.4.1.5040.1.2.33.3.1.6.2.1.1.3
This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2ButtonPortTable 1.3.6.1.4.1.5040.1.2.33.3.1.6.3.1
List of settings depending on the button number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtTrapReceiver2x2ButtonPortEntry

wtTrapReceiver2x2ButtonPortEntry 1.3.6.1.4.1.5040.1.2.33.3.1.6.3.1.1
Button parameter for the individual buttons.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtTrapReceiver2x2ButtonPortEntry  

wtTrapReceiver2x2PortButtonEnable 1.3.6.1.4.1.5040.1.2.33.3.1.6.3.1.1.1
Binary coded button enable: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: ungenutzt OCTET 2: ungenutzt OCTET 3: ungenutzt OCTET 4, Bit 1-7: ungenutzt Bit 0 : Button enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2PortButtonName 1.3.6.1.4.1.5040.1.2.33.3.1.6.3.1.1.2
Name of the button.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2PortButtonText 1.3.6.1.4.1.5040.1.2.33.3.1.6.3.1.1.3
Description of the button.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2PortButtonAccess 1.3.6.1.4.1.5040.1.2.33.3.1.6.3.1.1.4
Binary coded button access level: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 3-7: unused Bit 2 : For user administrator visible and operable Bit 1 : For user operator visible and operable Bit 0 : For user guest visible and operable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2InputPortTable 1.3.6.1.4.1.5040.1.2.33.3.1.6.4.1
List of settings depending on the input number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtTrapReceiver2x2InputPortEntry

wtTrapReceiver2x2InputPortEntry 1.3.6.1.4.1.5040.1.2.33.3.1.6.4.1.1
Input parameter for the individual inputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtTrapReceiver2x2InputPortEntry  

wtTrapReceiver2x2PortInputName 1.3.6.1.4.1.5040.1.2.33.3.1.6.4.1.1.1
Name of the input.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2PortInputText 1.3.6.1.4.1.5040.1.2.33.3.1.6.4.1.1.2
Description of the input.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2PortInputFilter 1.3.6.1.4.1.5040.1.2.33.3.1.6.4.1.1.4
Pulses with a duration shorter than here specified (duration in 1/1000 sec), are ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtTrapReceiver2x2OutputPortTable 1.3.6.1.4.1.5040.1.2.33.3.1.7.1.1
List of settings depending on the output number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtTrapReceiver2x2OutputPortEntry

wtTrapReceiver2x2OutputPortEntry 1.3.6.1.4.1.5040.1.2.33.3.1.7.1.1.1
Output parameters of the individual outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtTrapReceiver2x2OutputPortEntry  

wtTrapReceiver2x2PortOutputName 1.3.6.1.4.1.5040.1.2.33.3.1.7.1.1.1.1
Name of the output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2PortOutputText 1.3.6.1.4.1.5040.1.2.33.3.1.7.1.1.1.2
Description of the output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2PortPulseDuration 1.3.6.1.4.1.5040.1.2.33.3.1.7.1.1.1.9
Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtTrapReceiver2x2PortPulsePolarity 1.3.6.1.4.1.5040.1.2.33.3.1.7.1.1.1.10
This value defines the polarity of the output pulse, if wtTrapReceiver2x2PortPulseDuration is not set to zero. After the pulse is finished, the output switches back to the opposite state. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : negative polarity Bit 1 : positive polarity Bit 2-7 : unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtTrapReceiver2x2MfName 1.3.6.1.4.1.5040.1.2.33.3.3.1
Manufacturer company name
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2MfAddr 1.3.6.1.4.1.5040.1.2.33.3.3.2
Manufacturer address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2MfHotline 1.3.6.1.4.1.5040.1.2.33.3.3.3
Manufacturer hotline.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2MfInternet 1.3.6.1.4.1.5040.1.2.33.3.3.4
Manufacturer Internet address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2MfDeviceTyp 1.3.6.1.4.1.5040.1.2.33.3.3.5
Manufacturer device name (model number).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2DiagErrorCount 1.3.6.1.4.1.5040.1.2.33.4.1
Number of entries in the error memory.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtTrapReceiver2x2DiagBinaryError 1.3.6.1.4.1.5040.1.2.33.4.2
Error causes coded bit-by-bit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2DiagErrorIndex 1.3.6.1.4.1.5040.1.2.33.4.3
The value of this variable is used as an index to read an error massege from wtTrapReceiver2x2DiagErrorMessage. Errors are numbered from 1 to wtTrapReceiver2x2DiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtTrapReceiver2x2DiagErrorMessage.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtTrapReceiver2x2DiagErrorMessage 1.3.6.1.4.1.5040.1.2.33.4.4
Using wtTrapReceiver2x2DiagErrorIndex as an index, the appropriate message is available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtTrapReceiver2x2DiagErrorClear 1.3.6.1.4.1.5040.1.2.33.4.5
Writing 1 into this variable clears all diagnosis messages.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER  

wtTrapReceiver2x2Alert1 41
This SNMP trap is generated when Action 1 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtTrapReceiver2x2Alert2 42
This SNMP trap is generated when Action 2 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtTrapReceiver2x2Alert3 43
This SNMP trap is generated when Action 3 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtTrapReceiver2x2Alert4 44
This SNMP trap is generated when Action 4 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtTrapReceiver2x2Alert5 45
This SNMP trap is generated when Action 5 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtTrapReceiver2x2Alert6 46
This SNMP trap is generated when Action 6 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtTrapReceiver2x2Alert7 47
This SNMP trap is generated when Action 7 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtTrapReceiver2x2Alert8 48
This SNMP trap is generated when Action 8 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtTrapReceiver2x2Alert9 49
This SNMP trap is generated when Action 9 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtTrapReceiver2x2Alert10 50
This SNMP trap is generated when Action 10 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtTrapReceiver2x2Alert11 51
This SNMP trap is generated when Action 11 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtTrapReceiver2x2Alert12 52
This SNMP trap is generated when Action 12 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtTrapReceiver2x2AlertDiag 110
This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE