WebGraph-Thermometer-US-MIB

File: WebGraph-Thermometer-US-MIB.mib (67385 bytes)

Imported modules

RFC-1212 RFC-1215 RFC1213-MIB
RFC1155-SMI

Imported symbols

OBJECT-TYPE TRAP-TYPE DisplayString
PhysAddress enterprises TimeTicks
IpAddress NetworkAddress

Defined Types

WtWebioAn1GraphSensorEntry  
SEQUENCE    
  wtWebioAn1GraphSensorNo INTEGER

WtWebioAn1GraphTempValueEntry  
SEQUENCE    
  wtWebioAn1GraphTempValue OCTET STRING

WtWebioAn1GraphBinaryTempValueEntry  
SEQUENCE    
  wtWebioAn1GraphBinaryTempValue INTEGER

WtWebioAn1GraphSensorColorEntry  
SEQUENCE    
  wtWebioAn1GraphSensorColor OCTET STRING

WtWebioAn1GraphAlarmIfEntry  
SEQUENCE    
  wtWebioAn1GraphAlarmNo INTEGER

WtWebioAn1GraphAlarmEntry  
SEQUENCE    
  wtWebioAn1GraphAlarmTrigger OCTET STRING
  wtWebioAn1GraphAlarmMin OCTET STRING
  wtWebioAn1GraphAlarmMax OCTET STRING
  wtWebioAn1GraphAlarmHysteresis OCTET STRING
  wtWebioAn1GraphAlarmDelay OCTET STRING
  wtWebioAn1GraphAlarmInterval OCTET STRING
  wtWebioAn1GraphAlarmEnable OCTET STRING
  wtWebioAn1GraphAlarmEMailAddr OCTET STRING
  wtWebioAn1GraphAlarmMailSubject OCTET STRING
  wtWebioAn1GraphAlarmMailText OCTET STRING
  wtWebioAn1GraphAlarmManagerIP OCTET STRING
  wtWebioAn1GraphAlarmTrapText OCTET STRING
  wtWebioAn1GraphAlarmMailOptions OCTET STRING
  wtWebioAn1GraphAlarmTcpIpAddr OCTET STRING
  wtWebioAn1GraphAlarmTcpPort INTEGER
  wtWebioAn1GraphAlarmTcpText OCTET STRING
  wtWebioAn1GraphAlarmClearMailSubject OCTET STRING
  wtWebioAn1GraphAlarmClearMailText OCTET STRING
  wtWebioAn1GraphAlarmClearTrapText OCTET STRING
  wtWebioAn1GraphAlarmClearTcpText OCTET STRING
  wtWebioAn1GraphAlarmSyslogIpAddr OCTET STRING
  wtWebioAn1GraphAlarmSyslogPort INTEGER
  wtWebioAn1GraphAlarmSyslogText OCTET STRING
  wtWebioAn1GraphAlarmFtpDataPort OCTET STRING
  wtWebioAn1GraphAlarmFtpFileName OCTET STRING
  wtWebioAn1GraphAlarmFtpText OCTET STRING
  wtWebioAn1GraphAlarmFtpClearText OCTET STRING
  wtWebioAn1GraphAlarmFtpOption OCTET STRING
  wtWebioAn1GraphAlarmTimerCron OCTET STRING

WtWebioAn1GraphPortEntry  
SEQUENCE    
  wtWebioAn1GraphPortName OCTET STRING
  wtWebioAn1GraphPortText OCTET STRING
  wtWebioAn1GraphPortOffset1 OCTET STRING
  wtWebioAn1GraphPortTemperature1 OCTET STRING
  wtWebioAn1GraphPortOffset2 OCTET STRING
  wtWebioAn1GraphPortTemperature2 OCTET STRING
  wtWebioAn1GraphPortComment OCTET STRING

Defined Values

wut 1.3.6.1.4.1.5040
OBJECT IDENTIFIER    

wtComServer 1.3.6.1.4.1.5040.1
OBJECT IDENTIFIER    

wtWebio 1.3.6.1.4.1.5040.1.2
OBJECT IDENTIFIER    

wtWebioAn1Graph 1.3.6.1.4.1.5040.1.2.8
OBJECT IDENTIFIER    

wtWebioAn1GraphTemp 1.3.6.1.4.1.5040.1.2.8.1
OBJECT IDENTIFIER    

wtWebioAn1GraphSessCntrl 1.3.6.1.4.1.5040.1.2.8.2
OBJECT IDENTIFIER    

wtWebioAn1GraphConfig 1.3.6.1.4.1.5040.1.2.8.3
OBJECT IDENTIFIER    

wtWebioAn1GraphDevice 1.3.6.1.4.1.5040.1.2.8.3.1
OBJECT IDENTIFIER    

wtWebioAn1GraphPorts 1.3.6.1.4.1.5040.1.2.8.3.2
OBJECT IDENTIFIER    

wtWebioAn1GraphManufact 1.3.6.1.4.1.5040.1.2.8.3.3
OBJECT IDENTIFIER    

wtWebioAn1GraphDiag 1.3.6.1.4.1.5040.1.2.8.3.4
OBJECT IDENTIFIER    

wtWebioAn1GraphText 1.3.6.1.4.1.5040.1.2.8.3.1.1
OBJECT IDENTIFIER    

wtWebioAn1GraphTimeDate 1.3.6.1.4.1.5040.1.2.8.3.1.2
OBJECT IDENTIFIER    

wtWebioAn1GraphBasic 1.3.6.1.4.1.5040.1.2.8.3.1.3
OBJECT IDENTIFIER    

wtWebioAn1GraphDatalogger 1.3.6.1.4.1.5040.1.2.8.3.1.4
OBJECT IDENTIFIER    

wtWebioAn1GraphAlarm 1.3.6.1.4.1.5040.1.2.8.3.1.5
OBJECT IDENTIFIER    

wtWebioAn1GraphTimeZone 1.3.6.1.4.1.5040.1.2.8.3.1.2.1
OBJECT IDENTIFIER    

wtWebioAn1GraphTimeServer 1.3.6.1.4.1.5040.1.2.8.3.1.2.2
OBJECT IDENTIFIER    

wtWebioAn1GraphDeviceClock 1.3.6.1.4.1.5040.1.2.8.3.1.2.3
OBJECT IDENTIFIER    

wtWebioAn1GraphNetwork 1.3.6.1.4.1.5040.1.2.8.3.1.3.1
OBJECT IDENTIFIER    

wtWebioAn1GraphHTML 1.3.6.1.4.1.5040.1.2.8.3.1.3.2
OBJECT IDENTIFIER    

wtWebioAn1GraphMail 1.3.6.1.4.1.5040.1.2.8.3.1.3.3
OBJECT IDENTIFIER    

wtWebioAn1GraphSNMP 1.3.6.1.4.1.5040.1.2.8.3.1.3.4
OBJECT IDENTIFIER    

wtWebioAn1GraphUDP 1.3.6.1.4.1.5040.1.2.8.3.1.3.5
OBJECT IDENTIFIER    

wtWebioAn1GraphSyslog 1.3.6.1.4.1.5040.1.2.8.3.1.3.6
OBJECT IDENTIFIER    

wtWebioAn1GraphFTP 1.3.6.1.4.1.5040.1.2.8.3.1.3.7
OBJECT IDENTIFIER    

wtWebioAn1GraphHTTP 1.3.6.1.4.1.5040.1.2.8.3.1.3.8
OBJECT IDENTIFIER    

wtWebioAn1GraphSensors 1.3.6.1.4.1.5040.1.2.8.1.1
Number of temperature sensors
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..8  

wtWebioAn1GraphSensorTable 1.3.6.1.4.1.5040.1.2.8.1.2
List of sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioAn1GraphSensorEntry

wtWebioAn1GraphSensorEntry 1.3.6.1.4.1.5040.1.2.8.1.2.1
Temperature sensor numbers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioAn1GraphSensorEntry  

wtWebioAn1GraphSensorNo 1.3.6.1.4.1.5040.1.2.8.1.2.1.1
Temperature sensor number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebioAn1GraphTempValueTable 1.3.6.1.4.1.5040.1.2.8.1.3
List of temperature values corresponding to the channel numbers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioAn1GraphTempValueEntry

wtWebioAn1GraphTempValueEntry 1.3.6.1.4.1.5040.1.2.8.1.3.1
Temperatures of the sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioAn1GraphTempValueEntry  

wtWebioAn1GraphTempValue 1.3.6.1.4.1.5040.1.2.8.1.3.1.1
Temperature value of the sensor, ASCII, 5 characters in length.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(5)  

wtWebioAn1GraphBinaryTempValueTable 1.3.6.1.4.1.5040.1.2.8.1.4
List of binary temperature values corresponding to the channel numbers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioAn1GraphBinaryTempValueEntry

wtWebioAn1GraphBinaryTempValueEntry 1.3.6.1.4.1.5040.1.2.8.1.4.1
Binary temperature values of the sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioAn1GraphBinaryTempValueEntry  

wtWebioAn1GraphBinaryTempValue 1.3.6.1.4.1.5040.1.2.8.1.4.1.1
Binary temperature value of the sensor in 1/10 degrees Celsius, signed number, 0x7FFF indicates an invalid measured value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphSessCntrlPassword 1.3.6.1.4.1.5040.1.2.8.2.1
Entering this password opens a session which is ended by writing a 1 to wtWebioAn1GraphSessCntrlLogout. When read this variable provides a string of length zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphSessCntrlConfigMode 1.3.6.1.4.1.5040.1.2.8.2.2
When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtWebioAn1GraphSessCntrl-NoSession(0), wtWebioAn1GraphSessCntrl-Session(1)  

wtWebioAn1GraphSessCntrlLogout 1.3.6.1.4.1.5040.1.2.8.2.3
If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphSessCntrlAdminPassword 1.3.6.1.4.1.5040.1.2.8.2.4
This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphSessCntrlConfigPassword 1.3.6.1.4.1.5040.1.2.8.2.5
This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphDeviceName 1.3.6.1.4.1.5040.1.2.8.3.1.1.1
Name of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphDeviceText 1.3.6.1.4.1.5040.1.2.8.3.1.1.2
Description of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphDeviceLocation 1.3.6.1.4.1.5040.1.2.8.3.1.1.3
Description of the location of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphDeviceContact 1.3.6.1.4.1.5040.1.2.8.3.1.1.4
Contact address of the system operator of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphTzOffsetHrs 1.3.6.1.4.1.5040.1.2.8.3.1.2.1.1
Offset hours for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphTzOffsetMin 1.3.6.1.4.1.5040.1.2.8.3.1.2.1.2
Offset minutes for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphTzEnable 1.3.6.1.4.1.5040.1.2.8.3.1.2.1.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphStTzOffsetHrs 1.3.6.1.4.1.5040.1.2.8.3.1.2.1.4
Offset hours of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphStTzOffsetMin 1.3.6.1.4.1.5040.1.2.8.3.1.2.1.5
Offset minutes of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphStTzEnable 1.3.6.1.4.1.5040.1.2.8.3.1.2.1.6
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphStTzStartMonth 1.3.6.1.4.1.5040.1.2.8.3.1.2.1.7
Month in which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioAn1GraphStartMonth-January(1), wtWebioAn1GraphStartMonth-February(2), wtWebioAn1GraphStartMonth-March(3), wtWebioAn1GraphStartMonth-April(4), wtWebioAn1GraphStartMonth-May(5), wtWebioAn1GraphStartMonth-June(6), wtWebioAn1GraphStartMonth-July(7), wtWebioAn1GraphStartMonth-August(8), wtWebioAn1GraphStartMonth-September(9), wtWebioAn1GraphStartMonth-October(10), wtWebioAn1GraphStartMonth-November(11), wtWebioAn1GraphStartMonth-December(12)  

wtWebioAn1GraphStTzStartMode 1.3.6.1.4.1.5040.1.2.8.3.1.2.1.8
Mode of the day of the week for which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioAn1GraphStartMode-first(1), wtWebioAn1GraphStartMode-second(2), wtWebioAn1GraphStartMode-third(3), wtWebioAn1GraphStartMode-fourth(4), wtWebioAn1GraphStartMode-last(5)  

wtWebioAn1GraphStTzStartWday 1.3.6.1.4.1.5040.1.2.8.3.1.2.1.9
Day of the week on which the change is made from winter time to summer time
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioAn1GraphStartWday-Sunday(1), wtWebioAn1GraphStartWday-Monday(2), wtWebioAn1GraphStartWday-Tuesday(3), wtWebioAn1GraphStartWday-Thursday(4), wtWebioAn1GraphStartWday-Wednesday(5), wtWebioAn1GraphStartWday-Friday(6), wtWebioAn1GraphStartWday-Saturday(7)  

wtWebioAn1GraphStTzStartHrs 1.3.6.1.4.1.5040.1.2.8.3.1.2.1.10
Hour in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphStTzStartMin 1.3.6.1.4.1.5040.1.2.8.3.1.2.1.11
Minute in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphStTzStopMonth 1.3.6.1.4.1.5040.1.2.8.3.1.2.1.12
Month in which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioAn1GraphStopMonth-January(1), wtWebioAn1GraphStopMonth-February(2), wtWebioAn1GraphStopMonth-March(3), wtWebioAn1GraphStopMonth-April(4), wtWebioAn1GraphStopMonth-May(5), wtWebioAn1GraphStopMonth-June(6), wtWebioAn1GraphStopMonth-July(7), wtWebioAn1GraphStopMonth-August(8), wtWebioAn1GraphStopMonth-September(9), wtWebioAn1GraphStopMonth-October(10), wtWebioAn1GraphStopMonth-November(11), wtWebioAn1GraphStopMonth-December(12)  

wtWebioAn1GraphStTzStopMode 1.3.6.1.4.1.5040.1.2.8.3.1.2.1.13
Mode of the week day on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioAn1GraphStopMode-first(1), wtWebioAn1GraphStopMode-second(2), wtWebioAn1GraphStopMode-third(3), wtWebioAn1GraphStopMode-fourth(4), wtWebioAn1GraphStopMode-last(5)  

wtWebioAn1GraphStTzStopWday 1.3.6.1.4.1.5040.1.2.8.3.1.2.1.14
Day of the week on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioAn1GraphStopWday-Sunday(1), wtWebioAn1GraphStopWday-Monday(2), wtWebioAn1GraphStopWday-Tuesday(3), wtWebioAn1GraphStopWday-Thursday(4), wtWebioAn1GraphStopWday-Wednesday(5), wtWebioAn1GraphStopWday-Friday(6), wtWebioAn1GraphStopWday-Saturday(7)  

wtWebioAn1GraphStTzStopHrs 1.3.6.1.4.1.5040.1.2.8.3.1.2.1.15
Hour at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphStTzStopMin 1.3.6.1.4.1.5040.1.2.8.3.1.2.1.16
Minute at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphTimeServer1 1.3.6.1.4.1.5040.1.2.8.3.1.2.2.1
IP address or name of the 1st time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphTimeServer2 1.3.6.1.4.1.5040.1.2.8.3.1.2.2.2
IP address or name of the 2nd time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphTsEnable 1.3.6.1.4.1.5040.1.2.8.3.1.2.2.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphTsSyncTime 1.3.6.1.4.1.5040.1.2.8.3.1.2.2.4
Daily synchronisation time with the time server (hour: 0-23).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphClockHrs 1.3.6.1.4.1.5040.1.2.8.3.1.2.3.1
Clock hours taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..23  

wtWebioAn1GraphClockMin 1.3.6.1.4.1.5040.1.2.8.3.1.2.3.2
Clock minutes taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..59  

wtWebioAn1GraphClockDay 1.3.6.1.4.1.5040.1.2.8.3.1.2.3.3
Date: Day of the month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..31  

wtWebioAn1GraphClockMonth 1.3.6.1.4.1.5040.1.2.8.3.1.2.3.4
Date: Month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioAn1GraphClockMonth-January(1), wtWebioAn1GraphClockMonth-February(2), wtWebioAn1GraphClockMonth-March(3), wtWebioAn1GraphClockMonth-April(4), wtWebioAn1GraphClockMonth-May(5), wtWebioAn1GraphClockMonth-June(6), wtWebioAn1GraphClockMonth-July(7), wtWebioAn1GraphClockMonth-August(8), wtWebioAn1GraphClockMonth-September(9), wtWebioAn1GraphClockMonth-October(10), wtWebioAn1GraphClockMonth-November(11), wtWebioAn1GraphClockMonth-December(12)  

wtWebioAn1GraphClockYear 1.3.6.1.4.1.5040.1.2.8.3.1.2.3.5
Date: Year, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioAn1GraphIpAddress 1.3.6.1.4.1.5040.1.2.8.3.1.3.1.1
IP address of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioAn1GraphSubnetMask 1.3.6.1.4.1.5040.1.2.8.3.1.3.1.2
Subnet mask of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioAn1GraphGateway 1.3.6.1.4.1.5040.1.2.8.3.1.3.1.3
Gateway of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioAn1GraphDnsServer1 1.3.6.1.4.1.5040.1.2.8.3.1.3.1.4
IP address of the 1st DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphDnsServer2 1.3.6.1.4.1.5040.1.2.8.3.1.3.1.5
IP address of the 2nd DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphAddConfig 1.3.6.1.4.1.5040.1.2.8.3.1.3.1.6
Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: BOOTP disable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphStartup 1.3.6.1.4.1.5040.1.2.8.3.1.3.8.1
Binary coded start page: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: Index.htm Bit 2: Home.htm Bit 3: User.htm Only one page may be selected at a time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphGetHeaderEnable 1.3.6.1.4.1.5040.1.2.8.3.1.3.8.2
If this bit is set, every answer of a short form GET question will be lead by the IP-address and name of the device: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : GET Header enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphHttpPort 1.3.6.1.4.1.5040.1.2.8.3.1.3.8.3
Definition of the standard HTML port (Default: 80).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioAn1GraphMailAdName 1.3.6.1.4.1.5040.1.2.8.3.1.3.3.1
Device name for mail administration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphMailReply 1.3.6.1.4.1.5040.1.2.8.3.1.3.3.2
Reply address for the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphMailServer 1.3.6.1.4.1.5040.1.2.8.3.1.3.3.3
Name or IP address of the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1MailEnable 1.3.6.1.4.1.5040.1.2.8.3.1.3.3.4
Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphMailAuthentication 1.3.6.1.4.1.5040.1.2.8.3.1.3.3.5
Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphMailAuthUser 1.3.6.1.4.1.5040.1.2.8.3.1.3.3.6
Name of the user to be authenticated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphMailAuthPassword 1.3.6.1.4.1.5040.1.2.8.3.1.3.3.7
Authentication password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphMailPop3Server 1.3.6.1.4.1.5040.1.2.8.3.1.3.3.8
Name or Ip-address of the POP3 Servers.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphSnmpCommunityStringRead 1.3.6.1.4.1.5040.1.2.8.3.1.3.4.1
Community string read only
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphSnmpCommunityStringReadWrite 1.3.6.1.4.1.5040.1.2.8.3.1.3.4.2
Community string read / write
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphSystemTrapManagerIP 1.3.6.1.4.1.5040.1.2.8.3.1.3.4.3
Name or IP address of the TCP server which accepts the system trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphSystemTrapEnable 1.3.6.1.4.1.5040.1.2.8.3.1.3.4.4
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphSnmpEnable 1.3.6.1.4.1.5040.1.2.8.3.1.3.4.5
Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphSnmpCommunityStringTrap 1.3.6.1.4.1.5040.1.2.8.3.1.3.4.6
Community string of the traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphUdpPort 1.3.6.1.4.1.5040.1.2.8.3.1.3.5.1
Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioAn1GraphUdpEnable 1.3.6.1.4.1.5040.1.2.8.3.1.3.5.2
Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphSyslogServerIP 1.3.6.1.4.1.5040.1.2.8.3.1.3.6.1
Name or IP address of the Syslog server, which accepts the Syslog messgaes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphSyslogServerPort 1.3.6.1.4.1.5040.1.2.8.3.1.3.6.2
Portnumber of the Syslog servers, default 514.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphSyslogSystemMessagesEnable 1.3.6.1.4.1.5040.1.2.8.3.1.3.6.3
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphSyslogEnable 1.3.6.1.4.1.5040.1.2.8.3.1.3.6.4
Set bit 0 to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphFTPServerIP 1.3.6.1.4.1.5040.1.2.8.3.1.3.7.1
Name or IP address of the FTP server, which accepts the FTP messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphFTPServerControlPort 1.3.6.1.4.1.5040.1.2.8.3.1.3.7.2
Portnumber of the control port of the FTP server, default 21.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphFTPUserName 1.3.6.1.4.1.5040.1.2.8.3.1.3.7.3
FTP Loggin: user name.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphFTPPassword 1.3.6.1.4.1.5040.1.2.8.3.1.3.7.4
FTP Loggin: user password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphFTPAccount 1.3.6.1.4.1.5040.1.2.8.3.1.3.7.5
FTP Loggin: name of account.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphFTPOption 1.3.6.1.4.1.5040.1.2.8.3.1.3.7.6
Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphFTPEnable 1.3.6.1.4.1.5040.1.2.8.3.1.3.7.7
Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphLoggerTimebase 1.3.6.1.4.1.5040.1.2.8.3.1.4.1
Time base of the data logger
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioAn1GraphDatalogger-1Min(1), wtWebioAn1GraphDatalogger-5Min(2), wtWebioAn1GraphDatalogger-15Min(3), wtWebioAn1GraphDatalogger-60Min(4)  

wtWebioAn1GraphLoggerSensorSel 1.3.6.1.4.1.5040.1.2.8.3.1.4.2
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphDisplaySensorSel 1.3.6.1.4.1.5040.1.2.8.3.1.4.3
Binary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphSensorColorTable 1.3.6.1.4.1.5040.1.2.8.3.1.4.4
List of sensor colors for the praphical presentation.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioAn1GraphSensorColorEntry

wtWebioAn1GraphSensorColorEntry 1.3.6.1.4.1.5040.1.2.8.3.1.4.4.1
Index numbers of the sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioAn1GraphSensorColorEntry  

wtWebioAn1GraphSensorColor 1.3.6.1.4.1.5040.1.2.8.3.1.4.4.1.1
Color of the sensors at the praphical presention.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(3)  

wtWebioAn1GraphAutoScaleEnable 1.3.6.1.4.1.5040.1.2.8.3.1.4.5
If bit 0 is set, vertical auto scale is enabled: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Auto Scale enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphVerticalUpperLimit 1.3.6.1.4.1.5040.1.2.8.3.1.4.6
This value defines the maximum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphVerticalLowerLimit 1.3.6.1.4.1.5040.1.2.8.3.1.4.7
This value defines the minimum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphHorizontalZoom 1.3.6.1.4.1.5040.1.2.8.3.1.4.8
Defines the default zoom stage, if no auto scaling is selected.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioAn1GraphZoom-25min(1), wtWebioAn1GraphZoom-75min(2), wtWebioAn1GraphZoom-5hrs(3), wtWebioAn1GraphZoom-30hrs(4), wtWebioAn1GraphZoom-5days(5), wtWebioAn1GraphZoom-25days(6)  

wtWebioAn1GraphAlarmCount 1.3.6.1.4.1.5040.1.2.8.3.1.5.1
Number of independent alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..8  

wtWebioAn1GraphAlarmIfTable 1.3.6.1.4.1.5040.1.2.8.3.1.5.2
List of alarm indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioAn1GraphAlarmIfEntry

wtWebioAn1GraphAlarmIfEntry 1.3.6.1.4.1.5040.1.2.8.3.1.5.2.1
Numbers of the alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioAn1GraphAlarmIfEntry  

wtWebioAn1GraphAlarmNo 1.3.6.1.4.1.5040.1.2.8.3.1.5.2.1.1
Alarm number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..8  

wtWebioAn1GraphAlarmTable 1.3.6.1.4.1.5040.1.2.8.3.1.5.3
List of settings depending on the alarm number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioAn1GraphAlarmEntry

wtWebioAn1GraphAlarmEntry 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1
Alarm parameters of the individual alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioAn1GraphAlarmEntry  

wtWebioAn1GraphAlarmTrigger 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.1
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: Bit 0: Timer Bit 1: ColdStart Bit 2: WarmStart Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphAlarmMin 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.2
Minimum temperature in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphAlarmMax 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.3
Maximum temperature in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphAlarmHysteresis 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.4
Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.) , in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphAlarmDelay 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.5
Alarm will be delayed by setting this time while stable alarm condition occur (time in minutes).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphAlarmInterval 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.6
Send interval for alarm messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphAlarmEnable 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.7
Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphAlarmEMailAddr 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.8
E-Mail address for sending the alarm mail to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphAlarmMailSubject 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.9
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphAlarmMailText 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.10
Alarm mail text: provides the current temperature; n = 1..8. provides the current time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphAlarmManagerIP 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.11
Name or IP address of the SNMP Manager which accepts the trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphAlarmTrapText 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.12
This text is sent in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphAlarmMailOptions 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.13
Binary coded options: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphAlarmTcpIpAddr 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.14
Name or IP address of the TCP server which accepts the trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphAlarmTcpPort 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.15
Port number of the TCP server which accepts the trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioAn1GraphAlarmTcpText 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.16
This text is sent in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphAlarmClearMailSubject 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.17
Subject line for alarm clear mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphAlarmClearMailText 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.18
Alarm clear mail text: provides the current temperature; n = 1..8. provides the current time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphAlarmClearTrapText 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.19
This text is sent in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphAlarmClearTcpText 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.20
This text is sent in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphAlarmSyslogIpAddr 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.21
IP address of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioAn1GraphAlarmSyslogPort 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.22
Port number of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioAn1GraphAlarmSyslogText 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.23
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphAlarmSyslogClearText 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.24
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphAlarmFtpDataPort 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.25
Local data port: 1..65535 or AUTO: the next free port will be assigned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphAlarmFtpFileName 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.26
Name of the file including path informations.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphAlarmFtpText 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.27
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphAlarmFtpClearText 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.28
Alarm clear message to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphAlarmFtpOptions 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.29
Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphAlarmTimerCron 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.30
This entry contains 5 text fields space or tab seperated for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separately. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPortTable 1.3.6.1.4.1.5040.1.2.8.3.2.1
List of settings depending on the sensor number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioAn1GraphPortEntry

wtWebioAn1GraphPortEntry 1.3.6.1.4.1.5040.1.2.8.3.2.1.1
Sensor parameters for the individual sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioAn1GraphPortEntry  

wtWebioAn1GraphPortName 1.3.6.1.4.1.5040.1.2.8.3.2.1.1.1
Name of the sensor.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPortText 1.3.6.1.4.1.5040.1.2.8.3.2.1.1.2
Description of the sensor.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPortOffset1 1.3.6.1.4.1.5040.1.2.8.3.2.1.1.3
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPortTemperature1 1.3.6.1.4.1.5040.1.2.8.3.2.1.1.4
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPortOffset2 1.3.6.1.4.1.5040.1.2.8.3.2.1.1.5
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPortTemperature2 1.3.6.1.4.1.5040.1.2.8.3.2.1.1.6
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPortComment 1.3.6.1.4.1.5040.1.2.8.3.2.1.1.7
Offset calibration: informations of date, name of operator, reference devices.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphMfName 1.3.6.1.4.1.5040.1.2.8.3.3.1
Manufacturer company name
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphMfAddr 1.3.6.1.4.1.5040.1.2.8.3.3.2
Manufacturer address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphMfHotline 1.3.6.1.4.1.5040.1.2.8.3.3.3
Manufacturer hotline.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphMfInternet 1.3.6.1.4.1.5040.1.2.8.3.3.4
Manufacturer Internet address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphMfDeviceTyp 1.3.6.1.4.1.5040.1.2.8.3.3.5
Manufacturer device name (model number).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphMfOrderNo 1.3.6.1.4.1.5040.1.2.8.3.3.6
Manufacturer part number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphDiagErrorCount 1.3.6.1.4.1.5040.1.2.8.3.4.1
Number of entries in the error memory.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphDiagBinaryError 1.3.6.1.4.1.5040.1.2.8.3.4.2
Error causes coded bit-by-bit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphDiagErrorIndex 1.3.6.1.4.1.5040.1.2.8.3.4.3
The value of this variable is used as an index to read an error massege from wtWebioAn1GraphDiagErrorMessage. Errors are numbered from 1 to wtWebioAn1GraphDiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebioAn1GraphDiagErrorMessage.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphDiagErrorMessage 1.3.6.1.4.1.5040.1.2.8.3.4.4
Using wtWebioAn1GraphDiagErrorIndex as an index, the appropriate message is available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphDiagErrorClear 1.3.6.1.4.1.5040.1.2.8.3.4.5
Writing 1 into this variable clears all diagnosis messages.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphAlert1 31
This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphAlert2 32
This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphAlert3 33
This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphAlert4 34
This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphAlert5 35
This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphAlert6 36
This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphAlert7 37
This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphAlert8 38
This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphAlert9 91
This SNMP trap is generated when Alarm 1 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphAlert10 92
This SNMP trap is generated when Alarm 2 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphAlert11 93
This SNMP trap is generated when Alarm 3 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphAlert12 94
This SNMP trap is generated when Alarm 4 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphAlert13 95
This SNMP trap is generated when Alarm 5 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphAlert14 96
This SNMP trap is generated when Alarm 6 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphAlert15 97
This SNMP trap is generated when Alarm 7 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphAlert16 98
This SNMP trap is generated when Alarm 8 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphAlertDiag 110
This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE