WebGraph-Thermometer-PT-US-MIB

File: WebGraph-Thermometer-PT-US-MIB.mib (171659 bytes)

Imported modules

RFC-1212 RFC-1215 RFC1213-MIB
RFC1155-SMI

Imported symbols

OBJECT-TYPE TRAP-TYPE DisplayString
PhysAddress enterprises TimeTicks
IpAddress NetworkAddress

Defined Types

WtWebioAn1GraphPtSensorEntry  
SEQUENCE    
  wtWebioAn1GraphPtSensorNo INTEGER

WtWebioAn1GraphPtTempValueEntry  
SEQUENCE    
  wtWebioAn1GraphPtTempValue OCTET STRING

WtWebioAn1GraphPtBinaryTempValueEntry  
SEQUENCE    
  wtWebioAn1GraphPtBinaryTempValue INTEGER

WtWebioAn1GraphPtTempValuePktEntry  
SEQUENCE    
  wtWebioAn1GraphPtTempValuePkt OCTET STRING

WtWebioAn1GraphPtSensorColorEntry  
SEQUENCE    
  wtWebioAn1GraphPtSensorColor OCTET STRING

WtWebioAn1GraphPtAlarmIfEntry  
SEQUENCE    
  wtWebioAn1GraphPtAlarmNo INTEGER

WtWebioAn1GraphPtAlarmEntry  
SEQUENCE    
  wtWebioAn1GraphPtAlarmTrigger OCTET STRING
  wtWebioAn1GraphPtAlarmMin OCTET STRING
  wtWebioAn1GraphPtAlarmMax OCTET STRING
  wtWebioAn1GraphPtAlarmHysteresis OCTET STRING
  wtWebioAn1GraphPtAlarmDelay OCTET STRING
  wtWebioAn1GraphPtAlarmInterval OCTET STRING
  wtWebioAn1GraphPtAlarmEnable OCTET STRING
  wtWebioAn1GraphPtAlarmEMailAddr OCTET STRING
  wtWebioAn1GraphPtAlarmMailSubject OCTET STRING
  wtWebioAn1GraphPtAlarmMailText OCTET STRING
  wtWebioAn1GraphPtAlarmManagerIP OCTET STRING
  wtWebioAn1GraphPtAlarmTrapText OCTET STRING
  wtWebioAn1GraphPtAlarmMailOptions OCTET STRING
  wtWebioAn1GraphPtAlarmTcpIpAddr OCTET STRING
  wtWebioAn1GraphPtAlarmTcpPort INTEGER
  wtWebioAn1GraphPtAlarmTcpText OCTET STRING
  wtWebioAn1GraphPtAlarmClearMailSubject OCTET STRING
  wtWebioAn1GraphPtAlarmClearMailText OCTET STRING
  wtWebioAn1GraphPtAlarmClearTrapText OCTET STRING
  wtWebioAn1GraphPtAlarmClearTcpText OCTET STRING
  wtWebioAn1GraphPtAlarmSyslogIpAddr OCTET STRING
  wtWebioAn1GraphPtAlarmSyslogPort INTEGER
  wtWebioAn1GraphPtAlarmSyslogText OCTET STRING
  wtWebioAn1GraphPtAlarmFtpDataPort OCTET STRING
  wtWebioAn1GraphPtAlarmFtpFileName OCTET STRING
  wtWebioAn1GraphPtAlarmFtpText OCTET STRING
  wtWebioAn1GraphPtAlarmFtpClearText OCTET STRING
  wtWebioAn1GraphPtAlarmFtpOption OCTET STRING
  wtWebioAn1GraphPtAlarmTimerCron OCTET STRING
  wtWebioAn1GraphPtAlarmDeltaTemp OCTET STRING
  wtWebioAn1GraphPtAlarmName OCTET STRING
  wtWebioAn1GraphPtAlarmActive OCTET STRING

WtWebioAn1GraphPt2SensorColorEntry  
SEQUENCE    
  wtWebioAn1GraphPt2GraphicsSensorColor OCTET STRING
  wtWebioAn1GraphPt2GraphicsSelectScale OCTET STRING

WtWebioAn1GraphPtPortEntry  
SEQUENCE    
  wtWebioAn1GraphPtPortName OCTET STRING
  wtWebioAn1GraphPtPortText OCTET STRING
  wtWebioAn1GraphPtPortOffset1 OCTET STRING
  wtWebioAn1GraphPtPortTemperature1 OCTET STRING
  wtWebioAn1GraphPtPortOffset2 OCTET STRING
  wtWebioAn1GraphPtPortTemperature2 OCTET STRING
  wtWebioAn1GraphPtPortComment OCTET STRING
  wtWebioAn1GraphPtPortSensorSelect OCTET STRING

WtWebioAn1GraphPtSwSensorEntry  
SEQUENCE    
  wtWebioAn1GraphPtSwSensorNo INTEGER

WtWebioAn1GraphPtSwTempValueEntry  
SEQUENCE    
  wtWebioAn1GraphPtSwTempValue OCTET STRING

WtWebioAn1GraphPtSwBinaryTempValueEntry  
SEQUENCE    
  wtWebioAn1GraphPtSwBinaryTempValue INTEGER

WtWebioAn1GraphPtSwOutputEntry  
SEQUENCE    
  wtWebioAn1GraphPtSwOutputNo INTEGER

WtWebioAn1GraphPtSwBinaryOutputValueEntry  
SEQUENCE    
  wtWebioAn1GraphPtSwBinaryOutputValue INTEGER

WtWebioAn1GraphPtSwTempValuePktEntry  
SEQUENCE    
  wtWebioAn1GraphPtSwTempValuePkt OCTET STRING

WtWebioAn1GraphPtSwSensorColorEntry  
SEQUENCE    
  wtWebioAn1GraphPtSwSensorColor OCTET STRING

WtWebioAn1GraphPtSwAlarmIfEntry  
SEQUENCE    
  wtWebioAn1GraphPtSwAlarmNo INTEGER

WtWebioAn1GraphPtSwAlarmEntry  
SEQUENCE    
  wtWebioAn1GraphPtSwAlarmTrigger OCTET STRING
  wtWebioAn1GraphPtSwAlarmMin OCTET STRING
  wtWebioAn1GraphPtSwAlarmMax OCTET STRING
  wtWebioAn1GraphPtSwAlarmHysteresis OCTET STRING
  wtWebioAn1GraphPtSwAlarmDelay OCTET STRING
  wtWebioAn1GraphPtSwAlarmInterval OCTET STRING
  wtWebioAn1GraphPtSwAlarmEnable OCTET STRING
  wtWebioAn1GraphPtSwAlarmEMailAddr OCTET STRING
  wtWebioAn1GraphPtSwAlarmMailSubject OCTET STRING
  wtWebioAn1GraphPtSwAlarmMailText OCTET STRING
  wtWebioAn1GraphPtSwAlarmManagerIP OCTET STRING
  wtWebioAn1GraphPtSwAlarmTrapText OCTET STRING
  wtWebioAn1GraphPtSwAlarmMailOptions OCTET STRING
  wtWebioAn1GraphPtSwAlarmTcpIpAddr OCTET STRING
  wtWebioAn1GraphPtSwAlarmTcpPort INTEGER
  wtWebioAn1GraphPtSwAlarmTcpText OCTET STRING
  wtWebioAn1GraphPtSwAlarmClearMailSubject OCTET STRING
  wtWebioAn1GraphPtSwAlarmClearMailText OCTET STRING
  wtWebioAn1GraphPtSwAlarmClearTrapText OCTET STRING
  wtWebioAn1GraphPtSwAlarmClearTcpText OCTET STRING
  wtWebioAn1GraphPtSwAlarmSyslogIpAddr OCTET STRING
  wtWebioAn1GraphPtSwAlarmSyslogPort INTEGER
  wtWebioAn1GraphPtSwAlarmSyslogText OCTET STRING
  wtWebioAn1GraphPtSwAlarmFtpDataPort OCTET STRING
  wtWebioAn1GraphPtSwAlarmFtpFileName OCTET STRING
  wtWebioAn1GraphPtSwAlarmFtpText OCTET STRING
  wtWebioAn1GraphPtSwAlarmFtpClearText OCTET STRING
  wtWebioAn1GraphPtSwAlarmFtpOption OCTET STRING
  wtWebioAn1GraphPtSwAlarmTimerCron OCTET STRING
  wtWebioAn1GraphPtSwAlarmDeltaTemp OCTET STRING
  wtWebioAn1GraphPtSwAlarmName OCTET STRING
  wtWebioAn1GraphPtSwAlarmActive OCTET STRING

WtWebioAn1GraphPtSw2SensorColorEntry  
SEQUENCE    
  wtWebioAn1GraphPtSw2GraphicsSensorColor OCTET STRING
  wtWebioAn1GraphPtSw2GraphicsSelectScale OCTET STRING

WtWebioAn1GraphPtSwReportIfEntry  
SEQUENCE    
  wtWebioAn1GraphPtSwReportNo INTEGER

WtWebioAn1GraphPtSwReportEntry  
SEQUENCE    
  wtWebioAn1GraphPtSwReportEnable OCTET STRING
  wtWebioAn1GraphPtSwReportTimerCron OCTET STRING
  wtWebioAn1GraphPtSwReportMethodeEnable OCTET STRING
  wtWebioAn1GraphPtSwReportEMailAddr OCTET STRING
  wtWebioAn1GraphPtSwReportMailSubject OCTET STRING
  wtWebioAn1GraphPtSwReportMailText OCTET STRING
  wtWebioAn1GraphPtSwReportManagerIP OCTET STRING
  wtWebioAn1GraphPtSwReportTrapText OCTET STRING
  wtWebioAn1GraphPtSwReportMailOptions OCTET STRING
  wtWebioAn1GraphPtSwReportTcpIpAddr OCTET STRING
  wtWebioAn1GraphPtSwReportTcpPort INTEGER
  wtWebioAn1GraphPtSwReportTcpText OCTET STRING
  wtWebioAn1GraphPtSwReportClearMailSubject OCTET STRING
  wtWebioAn1GraphPtSwReportClearMailText OCTET STRING
  wtWebioAn1GraphPtSwReportClearTrapText OCTET STRING
  wtWebioAn1GraphPtSwReportClearTcpText OCTET STRING
  wtWebioAn1GraphPtSwReportSyslogIpAddr OCTET STRING
  wtWebioAn1GraphPtSwReportSyslogPort INTEGER
  wtWebioAn1GraphPtSwReportSyslogText OCTET STRING
  wtWebioAn1GraphPtSwReportSyslogClearText OCTET STRING
  wtWebioAn1GraphPtSwReportFtpDataPort OCTET STRING
  wtWebioAn1GraphPtSwReportFtpFileName OCTET STRING
  wtWebioAn1GraphPtSwReportFtpText OCTET STRING
  wtWebioAn1GraphPtSwReportFtpClearText OCTET STRING
  wtWebioAn1GraphPtSwReportFtpOption OCTET STRING

WtWebioAn1GraphPtSwPortEntry  
SEQUENCE    
  wtWebioAn1GraphPtSwPortName OCTET STRING
  wtWebioAn1GraphPtSwPortText OCTET STRING
  wtWebioAn1GraphPtSwPortOffset1 OCTET STRING
  wtWebioAn1GraphPtSwPortTemperature1 OCTET STRING
  wtWebioAn1GraphPtSwPortOffset2 OCTET STRING
  wtWebioAn1GraphPtSwPortTemperature2 OCTET STRING
  wtWebioAn1GraphPtSwPortComment OCTET STRING
  wtWebioAn1GraphPtSwPortSensorUnit OCTET STRING
  wtWebioAn1GraphPtPortSensorUnit OCTET STRING

WtWebioAn1GraphPtSwPortOutputEntry  
SEQUENCE    
  wtWebioAn1GraphPtSwPortOutputName OCTET STRING
  wtWebioAn1GraphPtSwPortOutputText OCTET STRING
  wtWebioAn1GraphPtSwPortOutputPolarity OCTET STRING
  wtWebioAn1GraphPtSwPortOutputComment OCTET STRING
  wtWebioAn1GraphPortOutputResetEnable OCTET STRING

Defined Values

wut 1.3.6.1.4.1.5040
OBJECT IDENTIFIER    

wtComServer 1.3.6.1.4.1.5040.1
OBJECT IDENTIFIER    

wtWebio 1.3.6.1.4.1.5040.1.2
OBJECT IDENTIFIER    

wtWebioAn1GraphPt 1.3.6.1.4.1.5040.1.2.17
OBJECT IDENTIFIER    

wtWebioAn1GraphPtSw 1.3.6.1.4.1.5040.1.2.23
OBJECT IDENTIFIER    

wtWebioAn1GraphPtTemp 1.3.6.1.4.1.5040.1.2.17.1
OBJECT IDENTIFIER    

wtWebioAn1GraphPtSessCntrl 1.3.6.1.4.1.5040.1.2.17.2
OBJECT IDENTIFIER    

wtWebioAn1GraphPtConfig 1.3.6.1.4.1.5040.1.2.17.3
OBJECT IDENTIFIER    

wtWebioAn1GraphPtDiag 1.3.6.1.4.1.5040.1.2.17.4
OBJECT IDENTIFIER    

wtWebioAn1GraphPtDevice 1.3.6.1.4.1.5040.1.2.17.3.1
OBJECT IDENTIFIER    

wtWebioAn1GraphPtPorts 1.3.6.1.4.1.5040.1.2.17.3.2
OBJECT IDENTIFIER    

wtWebioAn1GraphPtManufact 1.3.6.1.4.1.5040.1.2.17.3.3
OBJECT IDENTIFIER    

wtWebioAn1GraphPtText 1.3.6.1.4.1.5040.1.2.17.3.1.1
OBJECT IDENTIFIER    

wtWebioAn1GraphPtTimeDate 1.3.6.1.4.1.5040.1.2.17.3.1.2
OBJECT IDENTIFIER    

wtWebioAn1GraphPtBasic 1.3.6.1.4.1.5040.1.2.17.3.1.3
OBJECT IDENTIFIER    

wtWebioAn1GraphPtDatalogger 1.3.6.1.4.1.5040.1.2.17.3.1.4
OBJECT IDENTIFIER    

wtWebioAn1GraphPtAlarm 1.3.6.1.4.1.5040.1.2.17.3.1.5
OBJECT IDENTIFIER    

wtWebioAn1GraphPtGraphics 1.3.6.1.4.1.5040.1.2.17.3.1.6
OBJECT IDENTIFIER    

wtWebioAn1GraphPtTimeZone 1.3.6.1.4.1.5040.1.2.17.3.1.2.1
OBJECT IDENTIFIER    

wtWebioAn1GraphPtTimeServer 1.3.6.1.4.1.5040.1.2.17.3.1.2.2
OBJECT IDENTIFIER    

wtWebioAn1GraphPtDeviceClock 1.3.6.1.4.1.5040.1.2.17.3.1.2.3
OBJECT IDENTIFIER    

wtWebioAn1GraphPtNetwork 1.3.6.1.4.1.5040.1.2.17.3.1.3.1
OBJECT IDENTIFIER    

wtWebioAn1GraphPtHTTP 1.3.6.1.4.1.5040.1.2.17.3.1.3.2
OBJECT IDENTIFIER    

wtWebioAn1GraphPtMail 1.3.6.1.4.1.5040.1.2.17.3.1.3.3
OBJECT IDENTIFIER    

wtWebioAn1GraphPtSNMP 1.3.6.1.4.1.5040.1.2.17.3.1.3.4
OBJECT IDENTIFIER    

wtWebioAn1GraphPtUDP 1.3.6.1.4.1.5040.1.2.17.3.1.3.5
OBJECT IDENTIFIER    

wtWebioAn1GraphPtSyslog 1.3.6.1.4.1.5040.1.2.17.3.1.3.6
OBJECT IDENTIFIER    

wtWebioAn1GraphPtFTP 1.3.6.1.4.1.5040.1.2.17.3.1.3.7
OBJECT IDENTIFIER    

wtWebioAn1GraphPtLanguage 1.3.6.1.4.1.5040.1.2.17.3.1.3.9
OBJECT IDENTIFIER    

wtWebioAn1GraphPtGraphicsBase 1.3.6.1.4.1.5040.1.2.17.3.1.6.1
OBJECT IDENTIFIER    

wtWebioAn1GraphPtGraphicsSelect 1.3.6.1.4.1.5040.1.2.17.3.1.6.2
OBJECT IDENTIFIER    

wtWebioAn1GraphPtGraphicsScale 1.3.6.1.4.1.5040.1.2.17.3.1.6.3
OBJECT IDENTIFIER    

wtWebioAn1GraphPtSwTemp 1.3.6.1.4.1.5040.1.2.23.1
OBJECT IDENTIFIER    

wtWebioAn1GraphPtSwSessCntrl 1.3.6.1.4.1.5040.1.2.23.2
OBJECT IDENTIFIER    

wtWebioAn1GraphPtSwConfig 1.3.6.1.4.1.5040.1.2.23.3
OBJECT IDENTIFIER    

wtWebioAn1GraphPtSwDiag 1.3.6.1.4.1.5040.1.2.23.4
OBJECT IDENTIFIER    

wtWebioAn1GraphPtSwDevice 1.3.6.1.4.1.5040.1.2.23.3.1
OBJECT IDENTIFIER    

wtWebioAn1GraphPtSwPorts 1.3.6.1.4.1.5040.1.2.23.3.2
OBJECT IDENTIFIER    

wtWebioAn1GraphPtSwManufact 1.3.6.1.4.1.5040.1.2.23.3.3
OBJECT IDENTIFIER    

wtWebioAn1GraphPtSwText 1.3.6.1.4.1.5040.1.2.23.3.1.1
OBJECT IDENTIFIER    

wtWebioAn1GraphPtSwTimeDate 1.3.6.1.4.1.5040.1.2.23.3.1.2
OBJECT IDENTIFIER    

wtWebioAn1GraphPtSwBasic 1.3.6.1.4.1.5040.1.2.23.3.1.3
OBJECT IDENTIFIER    

wtWebioAn1GraphPtSwDatalogger 1.3.6.1.4.1.5040.1.2.23.3.1.4
OBJECT IDENTIFIER    

wtWebioAn1GraphPtSwAlarm 1.3.6.1.4.1.5040.1.2.23.3.1.5
OBJECT IDENTIFIER    

wtWebioAn1GraphPtSwGraphics 1.3.6.1.4.1.5040.1.2.23.3.1.6
OBJECT IDENTIFIER    

wtWebioAn1GraphPtSwReport 1.3.6.1.4.1.5040.1.2.23.3.1.7
OBJECT IDENTIFIER    

wtWebioAn1GraphPtSwTimeZone 1.3.6.1.4.1.5040.1.2.23.3.1.2.1
OBJECT IDENTIFIER    

wtWebioAn1GraphPtSwTimeServer 1.3.6.1.4.1.5040.1.2.23.3.1.2.2
OBJECT IDENTIFIER    

wtWebioAn1GraphPtSwDeviceClock 1.3.6.1.4.1.5040.1.2.23.3.1.2.3
OBJECT IDENTIFIER    

wtWebioAn1GraphPtSwNetwork 1.3.6.1.4.1.5040.1.2.23.3.1.3.1
OBJECT IDENTIFIER    

wtWebioAn1GraphPtSwHTTP 1.3.6.1.4.1.5040.1.2.23.3.1.3.2
OBJECT IDENTIFIER    

wtWebioAn1GraphPtSwMail 1.3.6.1.4.1.5040.1.2.23.3.1.3.3
OBJECT IDENTIFIER    

wtWebioAn1GraphPtSwSNMP 1.3.6.1.4.1.5040.1.2.23.3.1.3.4
OBJECT IDENTIFIER    

wtWebioAn1GraphPtSwUDP 1.3.6.1.4.1.5040.1.2.23.3.1.3.5
OBJECT IDENTIFIER    

wtWebioAn1GraphPtSwSyslog 1.3.6.1.4.1.5040.1.2.23.3.1.3.6
OBJECT IDENTIFIER    

wtWebioAn1GraphPtSwFTP 1.3.6.1.4.1.5040.1.2.23.3.1.3.7
OBJECT IDENTIFIER    

wtWebioAn1GraphPtSwLanguage 1.3.6.1.4.1.5040.1.2.23.3.1.3.9
OBJECT IDENTIFIER    

wtWebioAn1GraphPtSwGraphicsBase 1.3.6.1.4.1.5040.1.2.23.3.1.6.1
OBJECT IDENTIFIER    

wtWebioAn1GraphPtSwGraphicsSelect 1.3.6.1.4.1.5040.1.2.23.3.1.6.2
OBJECT IDENTIFIER    

wtWebioAn1GraphPtSwGraphicsScale 1.3.6.1.4.1.5040.1.2.23.3.1.6.3
OBJECT IDENTIFIER    

wtWebioAn1GraphPtSensors 1.3.6.1.4.1.5040.1.2.17.1.1
Number of temperature sensors
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebioAn1GraphPtSensorTable 1.3.6.1.4.1.5040.1.2.17.1.2
List of sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioAn1GraphPtSensorEntry

wtWebioAn1GraphPtSensorEntry 1.3.6.1.4.1.5040.1.2.17.1.2.1
Temperature sensor numbers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioAn1GraphPtSensorEntry  

wtWebioAn1GraphPtSensorNo 1.3.6.1.4.1.5040.1.2.17.1.2.1.1
Temperature sensor number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebioAn1GraphPtTempValueTable 1.3.6.1.4.1.5040.1.2.17.1.3
List of temperature values corresponding to the channel numbers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioAn1GraphPtTempValueEntry

wtWebioAn1GraphPtTempValueEntry 1.3.6.1.4.1.5040.1.2.17.1.3.1
Temperatures of the sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioAn1GraphPtTempValueEntry  

wtWebioAn1GraphPtTempValue 1.3.6.1.4.1.5040.1.2.17.1.3.1.1
Temperature value of the sensor, ASCII, 5 characters in length.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(5)  

wtWebioAn1GraphPtBinaryTempValueTable 1.3.6.1.4.1.5040.1.2.17.1.4
List of binary temperature values corresponding to the channel numbers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioAn1GraphPtBinaryTempValueEntry

wtWebioAn1GraphPtBinaryTempValueEntry 1.3.6.1.4.1.5040.1.2.17.1.4.1
Binary temperature values of the sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioAn1GraphPtBinaryTempValueEntry  

wtWebioAn1GraphPtBinaryTempValue 1.3.6.1.4.1.5040.1.2.17.1.4.1.1
Binary temperature value of the sensor in 1/10 degrees Celsius, signed number, 0x7FFF indicates an invalid measured value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtTempValuePktTable 1.3.6.1.4.1.5040.1.2.17.1.8
List of temperature values corresponding to the channel numbers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioAn1GraphPtTempValuePktEntry

wtWebioAn1GraphPtTempValuePktEntry 1.3.6.1.4.1.5040.1.2.17.1.8.1
Temperatures of the sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioAn1GraphPtTempValuePktEntry  

wtWebioAn1GraphPtTempValuePkt 1.3.6.1.4.1.5040.1.2.17.1.8.1.1
Temperature value of the sensor, ASCII, 5 characters in length, decimal point.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(5)  

wtWebioAn1GraphPtSessCntrlPassword 1.3.6.1.4.1.5040.1.2.17.2.1
Entering this password opens a session which is ended by writing a 1 to wtWebioAn1GraphPtSessCntrlLogout. When read this variable provides a string of length zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSessCntrlConfigMode 1.3.6.1.4.1.5040.1.2.17.2.2
When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtWebioAn1GraphPtSessCntrl-NoSession(0), wtWebioAn1GraphPtSessCntrl-Session(1)  

wtWebioAn1GraphPtSessCntrlLogout 1.3.6.1.4.1.5040.1.2.17.2.3
If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtSessCntrlAdminPassword 1.3.6.1.4.1.5040.1.2.17.2.4
This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSessCntrlConfigPassword 1.3.6.1.4.1.5040.1.2.17.2.5
This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtDeviceName 1.3.6.1.4.1.5040.1.2.17.3.1.1.1
Name of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtDeviceText 1.3.6.1.4.1.5040.1.2.17.3.1.1.2
Description of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtDeviceLocation 1.3.6.1.4.1.5040.1.2.17.3.1.1.3
Description of the location of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtDeviceContact 1.3.6.1.4.1.5040.1.2.17.3.1.1.4
Contact address of the system operator of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtTzOffsetHrs 1.3.6.1.4.1.5040.1.2.17.3.1.2.1.1
Offset hours for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtTzOffsetMin 1.3.6.1.4.1.5040.1.2.17.3.1.2.1.2
Offset minutes for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtTzEnable 1.3.6.1.4.1.5040.1.2.17.3.1.2.1.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtStTzOffsetHrs 1.3.6.1.4.1.5040.1.2.17.3.1.2.1.4
Offset hours of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtStTzOffsetMin 1.3.6.1.4.1.5040.1.2.17.3.1.2.1.5
Offset minutes of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtStTzEnable 1.3.6.1.4.1.5040.1.2.17.3.1.2.1.6
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtStTzStartMonth 1.3.6.1.4.1.5040.1.2.17.3.1.2.1.7
Month in which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioAn1GraphPtStartMonth-January(1), wtWebioAn1GraphPtStartMonth-February(2), wtWebioAn1GraphPtStartMonth-March(3), wtWebioAn1GraphPtStartMonth-April(4), wtWebioAn1GraphPtStartMonth-May(5), wtWebioAn1GraphPtStartMonth-June(6), wtWebioAn1GraphPtStartMonth-July(7), wtWebioAn1GraphPtStartMonth-August(8), wtWebioAn1GraphPtStartMonth-September(9), wtWebioAn1GraphPtStartMonth-October(10), wtWebioAn1GraphPtStartMonth-November(11), wtWebioAn1GraphPtStartMonth-December(12)  

wtWebioAn1GraphPtStTzStartMode 1.3.6.1.4.1.5040.1.2.17.3.1.2.1.8
Mode of the day of the week for which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioAn1GraphPtStartMode-first(1), wtWebioAn1GraphPtStartMode-second(2), wtWebioAn1GraphPtStartMode-third(3), wtWebioAn1GraphPtStartMode-fourth(4), wtWebioAn1GraphPtStartMode-last(5)  

wtWebioAn1GraphPtStTzStartWday 1.3.6.1.4.1.5040.1.2.17.3.1.2.1.9
Day of the week on which the change is made from winter time to summer time
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioAn1GraphPtStartWday-Sunday(1), wtWebioAn1GraphPtStartWday-Monday(2), wtWebioAn1GraphPtStartWday-Tuesday(3), wtWebioAn1GraphPtStartWday-Thursday(4), wtWebioAn1GraphPtStartWday-Wednesday(5), wtWebioAn1GraphPtStartWday-Friday(6), wtWebioAn1GraphPtStartWday-Saturday(7)  

wtWebioAn1GraphPtStTzStartHrs 1.3.6.1.4.1.5040.1.2.17.3.1.2.1.10
Hour in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtStTzStartMin 1.3.6.1.4.1.5040.1.2.17.3.1.2.1.11
Minute in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtStTzStopMonth 1.3.6.1.4.1.5040.1.2.17.3.1.2.1.12
Month in which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioAn1GraphPtStopMonth-January(1), wtWebioAn1GraphPtStopMonth-February(2), wtWebioAn1GraphPtStopMonth-March(3), wtWebioAn1GraphPtStopMonth-April(4), wtWebioAn1GraphPtStopMonth-May(5), wtWebioAn1GraphPtStopMonth-June(6), wtWebioAn1GraphPtStopMonth-July(7), wtWebioAn1GraphPtStopMonth-August(8), wtWebioAn1GraphPtStopMonth-September(9), wtWebioAn1GraphPtStopMonth-October(10), wtWebioAn1GraphPtStopMonth-November(11), wtWebioAn1GraphPtStopMonth-December(12)  

wtWebioAn1GraphPtStTzStopMode 1.3.6.1.4.1.5040.1.2.17.3.1.2.1.13
Mode of the week day on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioAn1GraphPtStopMode-first(1), wtWebioAn1GraphPtStopMode-second(2), wtWebioAn1GraphPtStopMode-third(3), wtWebioAn1GraphPtStopMode-fourth(4), wtWebioAn1GraphPtStopMode-last(5)  

wtWebioAn1GraphPtStTzStopWday 1.3.6.1.4.1.5040.1.2.17.3.1.2.1.14
Day of the week on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioAn1GraphPtStopWday-Sunday(1), wtWebioAn1GraphPtStopWday-Monday(2), wtWebioAn1GraphPtStopWday-Tuesday(3), wtWebioAn1GraphPtStopWday-Thursday(4), wtWebioAn1GraphPtStopWday-Wednesday(5), wtWebioAn1GraphPtStopWday-Friday(6), wtWebioAn1GraphPtStopWday-Saturday(7)  

wtWebioAn1GraphPtStTzStopHrs 1.3.6.1.4.1.5040.1.2.17.3.1.2.1.15
Hour at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtStTzStopMin 1.3.6.1.4.1.5040.1.2.17.3.1.2.1.16
Minute at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtTimeServer1 1.3.6.1.4.1.5040.1.2.17.3.1.2.2.1
IP address or name of the 1st time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtTimeServer2 1.3.6.1.4.1.5040.1.2.17.3.1.2.2.2
IP address or name of the 2nd time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtTsEnable 1.3.6.1.4.1.5040.1.2.17.3.1.2.2.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtTsSyncTime 1.3.6.1.4.1.5040.1.2.17.3.1.2.2.4
Daily synchronisation time with the time server (hour: 0-23).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtClockHrs 1.3.6.1.4.1.5040.1.2.17.3.1.2.3.1
Clock hours taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..23  

wtWebioAn1GraphPtClockMin 1.3.6.1.4.1.5040.1.2.17.3.1.2.3.2
Clock minutes taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..59  

wtWebioAn1GraphPtClockDay 1.3.6.1.4.1.5040.1.2.17.3.1.2.3.3
Date: Day of the month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..31  

wtWebioAn1GraphPtClockMonth 1.3.6.1.4.1.5040.1.2.17.3.1.2.3.4
Date: Month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioAn1GraphPtClockMonth-January(1), wtWebioAn1GraphPtClockMonth-February(2), wtWebioAn1GraphPtClockMonth-March(3), wtWebioAn1GraphPtClockMonth-April(4), wtWebioAn1GraphPtClockMonth-May(5), wtWebioAn1GraphPtClockMonth-June(6), wtWebioAn1GraphPtClockMonth-July(7), wtWebioAn1GraphPtClockMonth-August(8), wtWebioAn1GraphPtClockMonth-September(9), wtWebioAn1GraphPtClockMonth-October(10), wtWebioAn1GraphPtClockMonth-November(11), wtWebioAn1GraphPtClockMonth-December(12)  

wtWebioAn1GraphPtClockYear 1.3.6.1.4.1.5040.1.2.17.3.1.2.3.5
Date: Year, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioAn1GraphPtIpAddress 1.3.6.1.4.1.5040.1.2.17.3.1.3.1.1
IP address of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioAn1GraphPtSubnetMask 1.3.6.1.4.1.5040.1.2.17.3.1.3.1.2
Subnet mask of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioAn1GraphPtGateway 1.3.6.1.4.1.5040.1.2.17.3.1.3.1.3
Gateway of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioAn1GraphPtDnsServer1 1.3.6.1.4.1.5040.1.2.17.3.1.3.1.4
IP address of the 1st DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtDnsServer2 1.3.6.1.4.1.5040.1.2.17.3.1.3.1.5
IP address of the 2nd DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtAddConfig 1.3.6.1.4.1.5040.1.2.17.3.1.3.1.6
Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP disable Bit 0: BOOTP disable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtStartup 1.3.6.1.4.1.5040.1.2.17.3.1.3.2.1
Binary coded start page: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: Index.htm Bit 2: Home.htm Bit 3: User.htm Only one page may be selected at a time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtGetHeaderEnable 1.3.6.1.4.1.5040.1.2.17.3.1.3.2.2
If these bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device and/or a HTTP header: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-6: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtHttpPort 1.3.6.1.4.1.5040.1.2.17.3.1.3.2.3
Definition of the standard HTML port (Default: 80).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioAn1GraphPtMailAdName 1.3.6.1.4.1.5040.1.2.17.3.1.3.3.1
Device name for mail administration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtMailReply 1.3.6.1.4.1.5040.1.2.17.3.1.3.3.2
Reply address for the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtMailServer 1.3.6.1.4.1.5040.1.2.17.3.1.3.3.3
Name or IP address of the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtMailEnable 1.3.6.1.4.1.5040.1.2.17.3.1.3.3.4
Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtMailAuthentication 1.3.6.1.4.1.5040.1.2.17.3.1.3.3.5
Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtMailAuthUser 1.3.6.1.4.1.5040.1.2.17.3.1.3.3.6
Name of the user to be authenticated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtMailAuthPassword 1.3.6.1.4.1.5040.1.2.17.3.1.3.3.7
Authentication password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtMailPop3Server 1.3.6.1.4.1.5040.1.2.17.3.1.3.3.8
Name or Ip-address of the POP3 Servers.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSnmpCommunityStringRead 1.3.6.1.4.1.5040.1.2.17.3.1.3.4.1
Community string read only
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSnmpCommunityStringReadWrite 1.3.6.1.4.1.5040.1.2.17.3.1.3.4.2
Community string read / write
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSystemTrapManagerIP 1.3.6.1.4.1.5040.1.2.17.3.1.3.4.3
Name or IP address of the TCP server which accepts the system trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSystemTrapEnable 1.3.6.1.4.1.5040.1.2.17.3.1.3.4.4
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtSnmpEnable 1.3.6.1.4.1.5040.1.2.17.3.1.3.4.5
Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSnmpCommunityStringTrap 1.3.6.1.4.1.5040.1.2.17.3.1.3.4.6
Community string send within traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtUdpPort 1.3.6.1.4.1.5040.1.2.17.3.1.3.5.1
Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioAn1GraphPtUdpEnable 1.3.6.1.4.1.5040.1.2.17.3.1.3.5.2
Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSyslogServerIP 1.3.6.1.4.1.5040.1.2.17.3.1.3.6.1
Name or IP address of the Syslog server, which accepts the Syslog messgaes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSyslogServerPort 1.3.6.1.4.1.5040.1.2.17.3.1.3.6.2
Portnumber of the Syslog servers, default 514.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtSyslogSystemMessagesEnable 1.3.6.1.4.1.5040.1.2.17.3.1.3.6.3
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtSyslogEnable 1.3.6.1.4.1.5040.1.2.17.3.1.3.6.4
Set bit 0 to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtFTPServerIP 1.3.6.1.4.1.5040.1.2.17.3.1.3.7.1
Name or IP address of the FTP server, which accepts the FTP messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtFTPServerControlPort 1.3.6.1.4.1.5040.1.2.17.3.1.3.7.2
Portnumber of the control port of the FTP server, default 21.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtFTPUserName 1.3.6.1.4.1.5040.1.2.17.3.1.3.7.3
FTP Loggin: user name.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtFTPPassword 1.3.6.1.4.1.5040.1.2.17.3.1.3.7.4
FTP Loggin: user password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtFTPAccount 1.3.6.1.4.1.5040.1.2.17.3.1.3.7.5
FTP Loggin: name of account.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtFTPOption 1.3.6.1.4.1.5040.1.2.17.3.1.3.7.6
Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtFTPEnable 1.3.6.1.4.1.5040.1.2.17.3.1.3.7.7
Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtLanguageSelect 1.3.6.1.4.1.5040.1.2.17.3.1.3.9.1
Language selection: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2-7: unused Bit 1 : english Bit 0 : german
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtLoggerTimebase 1.3.6.1.4.1.5040.1.2.17.3.1.4.1
Time base of the data logger
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioAn1GraphPtDatalogger-1Min(1), wtWebioAn1GraphPtDatalogger-5Min(2), wtWebioAn1GraphPtDatalogger-15Min(3), wtWebioAn1GraphPtDatalogger-60Min(4)  

wtWebioAn1GraphPtLoggerSensorSel 1.3.6.1.4.1.5040.1.2.17.3.1.4.2
Binary coded sensor selection: only selected sensors will be logged. Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtDisplaySensorSel 1.3.6.1.4.1.5040.1.2.17.3.1.4.3
Binary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtSensorColorTable 1.3.6.1.4.1.5040.1.2.17.3.1.4.4
List of sensor colors for the praphical presentation.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioAn1GraphPtSensorColorEntry

wtWebioAn1GraphPtSensorColorEntry 1.3.6.1.4.1.5040.1.2.17.3.1.4.4.1
Index numbers of the sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioAn1GraphPtSensorColorEntry  

wtWebioAn1GraphPtSensorColor 1.3.6.1.4.1.5040.1.2.17.3.1.4.4.1.1
Color of the sensors at the praphical presention.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(3)  

wtWebioAn1GraphPtAutoScaleEnable 1.3.6.1.4.1.5040.1.2.17.3.1.4.5
If bit 0 is set, vertical auto scale is enabled: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Auto Scale enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtVerticalUpperLimit 1.3.6.1.4.1.5040.1.2.17.3.1.4.6
This value defines the maximum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtVerticalLowerLimit 1.3.6.1.4.1.5040.1.2.17.3.1.4.7
This value defines the minimum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtHorizontalZoom 1.3.6.1.4.1.5040.1.2.17.3.1.4.8
Defines the default zoom stage, if no auto scaling is selected.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioAn1GraphPtZoom-25min(1), wtWebioAn1GraphPtZoom-75min(2), wtWebioAn1GraphPtZoom-5hrs(3), wtWebioAn1GraphPtZoom-30hrs(4), wtWebioAn1GraphPtZoom-5days(5), wtWebioAn1GraphPtZoom-25days(6)  

wtWebioAn1GraphPtAlarmCount 1.3.6.1.4.1.5040.1.2.17.3.1.5.1
Number of independent alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..8  

wtWebioAn1GraphPtAlarmIfTable 1.3.6.1.4.1.5040.1.2.17.3.1.5.2
List of alarm indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioAn1GraphPtAlarmIfEntry

wtWebioAn1GraphPtAlarmIfEntry 1.3.6.1.4.1.5040.1.2.17.3.1.5.2.1
Numbers of the alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioAn1GraphPtAlarmIfEntry  

wtWebioAn1GraphPtAlarmNo 1.3.6.1.4.1.5040.1.2.17.3.1.5.2.1.1
Alarm number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..8  

wtWebioAn1GraphPtAlarmTable 1.3.6.1.4.1.5040.1.2.17.3.1.5.3
List of settings depending on the alarm number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioAn1GraphPtAlarmEntry

wtWebioAn1GraphPtAlarmEntry 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1
Alarm parameters of the individual alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioAn1GraphPtAlarmEntry  

wtWebioAn1GraphPtAlarmTrigger 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.1
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: Bit 0 : Timer Bit 1 : ColdStart Bit 2 : WarmStart Bit 3 : Sensor lost Bit 4-7: unused Octet 4: Bit 0 : Sensor 1 Bit 1-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtAlarmMin 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.2
Minimum temperature in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtAlarmMax 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.3
Maximum temperature in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtAlarmHysteresis 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.4
Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.) , in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtAlarmDelay 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.5
Alarm will be delayed by setting this time while stable alarm condition occur (time in minutes).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtAlarmInterval 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.6
Send interval for alarm messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtAlarmEnable 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.7
Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Mail Enable Bit 1 : SNMP Trap enable Bit 2 : TCP Client enable Bit 3 : Syslog Messages enable Bit 4 : FTP enable Bit 5-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtAlarmEMailAddr 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.8
E-Mail address for sending the alarm mail to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtAlarmMailSubject 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.9
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtAlarmMailText 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.10
Alarm mail text: provides the current temperature; n = 1..8. provides the current time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtAlarmManagerIP 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.11
Name or IP address of the SNMP Manager which accepts the trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtAlarmTrapText 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.12
This text is sent in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtAlarmMailOptions 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.13
Binary coded options: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtAlarmTcpIpAddr 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.14
Name or IP address of the TCP server which accepts the trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtAlarmTcpPort 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.15
Port number of the TCP server which accepts the trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioAn1GraphPtAlarmTcpText 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.16
This text is sent in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtAlarmClearMailSubject 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.17
Subject line for alarm clear mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtAlarmClearMailText 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.18
Alarm clear mail text: provides the current temperature; n = 1..8. provides the current time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtAlarmClearTrapText 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.19
This text is sent in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtAlarmClearTcpText 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.20
This text is sent in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtAlarmSyslogIpAddr 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.21
IP address of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioAn1GraphPtAlarmSyslogPort 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.22
Port number of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioAn1GraphPtAlarmSyslogText 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.23
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtAlarmSyslogClearText 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.24
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtAlarmFtpDataPort 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.25
Local data port: 1..65535 or AUTO: the next free port will be assigned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtAlarmFtpFileName 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.26
Name of the file including path informations.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtAlarmFtpText 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.27
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtAlarmFtpClearText 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.28
Alarm clear message to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtAlarmFtpOption 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.29
Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtAlarmTimerCron 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.30
This entry defines a time window for alarm 1-8 and a activation time for the report. A time window is definied by start and stop time stamp, seperated by a space or tab. The activation time of the report is defined by a single start time stamp. Each time stamp contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger an action, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas (i.e.: 2,14,22) - a partition within the allowed range (i.e.: 1-5) - step size within a partition of the allowed range (i.e.: 0-59/2 every second minute).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtAlarmDeltaTemp 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.31
Maximum rate of change degrees/min with maximum 2 decimal places. Compared with the average of a period of 5 minutes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtAlarmName 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.39
Alert name
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtAlarmActive 1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.40
Alert active 1 = ON 0 = OFF
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtGraphicsBaseEnable 1.3.6.1.4.1.5040.1.2.17.3.1.6.1.1
Defines the viewing options of the graphic: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Auto scroll enable Bit 1 : Show table Bit 2 : Show graph Bit 3 : Show control buttons Bit 4 : Show config menu Bit 5 : Show Logo Bit 6-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtGraphicsBaseWidth 1.3.6.1.4.1.5040.1.2.17.3.1.6.1.2
Defines the width of the graphic in pixels.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtGraphicsBaseHeight 1.3.6.1.4.1.5040.1.2.17.3.1.6.1.3
Defines the height of the graphic in pixels.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtGraphicsBaseFrameColor 1.3.6.1.4.1.5040.1.2.17.3.1.6.1.4
Frame color definition in RGB.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(3)  

wtWebioAn1GraphPtGraphicsBaseBackgroundColor 1.3.6.1.4.1.5040.1.2.17.3.1.6.1.5
Background color definition in RGB.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(3)  

wtWebioAn1GraphPtGraphicsBasePollingrate 1.3.6.1.4.1.5040.1.2.17.3.1.6.1.6
Defines the pollingrate in seconds, which defines the refreshing intervall of the graphic.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtGraphicsSelectDisplaySensorSel 1.3.6.1.4.1.5040.1.2.17.3.1.6.2.1
Binary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Sensor 1 Bit 1-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtGraphicsSelectDisplayShowExtrem 1.3.6.1.4.1.5040.1.2.17.3.1.6.2.2
Binary coded sensor selection: only selected sensors will be shown with minima and maxima: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Sensor 1 Bit 1-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPt2SensorColorTable 1.3.6.1.4.1.5040.1.2.17.3.1.6.2.3
List of sensor colors for the praphical presentation.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioAn1GraphPt2SensorColorEntry

wtWebioAn1GraphPt2SensorColorEntry 1.3.6.1.4.1.5040.1.2.17.3.1.6.2.3.1
Numbers of the sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioAn1GraphPt2SensorColorEntry  

wtWebioAn1GraphPt2GraphicsSensorColor 1.3.6.1.4.1.5040.1.2.17.3.1.6.2.3.1.1
Color of the sensors at the praphical presention.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(3)  

wtWebioAn1GraphPt2GraphicsSelectScale 1.3.6.1.4.1.5040.1.2.17.3.1.6.2.3.1.2
Assignes one of 4 scales to a sensor: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Use Scale 1 Bit 1-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtGraphicsScaleAutoScaleEnable 1.3.6.1.4.1.5040.1.2.17.3.1.6.3.1
Select the Auto Scale Mode: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto scale enable Bit 1-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtGraphicsScaleAutoFitEnable 1.3.6.1.4.1.5040.1.2.17.3.1.6.3.2
Select the Auto Fit Mode:: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto fit enable Bit 1-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtGraphicsScale1Min 1.3.6.1.4.1.5040.1.2.17.3.1.6.3.3
Scale 1: Minimum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtGraphicsScale2Min 1.3.6.1.4.1.5040.1.2.17.3.1.6.3.4
Scale 2: Minimum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtGraphicsScale3Min 1.3.6.1.4.1.5040.1.2.17.3.1.6.3.5
Scale 3: Minimum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtGraphicsScale4Min 1.3.6.1.4.1.5040.1.2.17.3.1.6.3.6
Scale 4: Minimum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtGraphicsScale1Max 1.3.6.1.4.1.5040.1.2.17.3.1.6.3.7
Scale 1: Maximum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtGraphicsScale2Max 1.3.6.1.4.1.5040.1.2.17.3.1.6.3.8
Scale 2: Maximum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtGraphicsScale3Max 1.3.6.1.4.1.5040.1.2.17.3.1.6.3.9
Scale 3: Maximum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtGraphicsScale4Max 1.3.6.1.4.1.5040.1.2.17.3.1.6.3.10
Scale 4: Maximum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtGraphicsScale1Unit 1.3.6.1.4.1.5040.1.2.17.3.1.6.3.11
Scale 1: Unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtGraphicsScale2Unit 1.3.6.1.4.1.5040.1.2.17.3.1.6.3.12
Scale 2: Unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtGraphicsScale3Unit 1.3.6.1.4.1.5040.1.2.17.3.1.6.3.13
Scale 3: Unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtGraphicsScale4Unit 1.3.6.1.4.1.5040.1.2.17.3.1.6.3.14
Scale 4: Unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtPortTable 1.3.6.1.4.1.5040.1.2.17.3.2.1
List of settings depending on the sensor number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioAn1GraphPtPortEntry

wtWebioAn1GraphPtPortEntry 1.3.6.1.4.1.5040.1.2.17.3.2.1.1
Sensor parameters for the individual sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioAn1GraphPtPortEntry  

wtWebioAn1GraphPtPortName 1.3.6.1.4.1.5040.1.2.17.3.2.1.1.1
Name of the sensor.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtPortText 1.3.6.1.4.1.5040.1.2.17.3.2.1.1.2
Description of the sensor.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtPortOffset1 1.3.6.1.4.1.5040.1.2.17.3.2.1.1.3
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtPortTemperature1 1.3.6.1.4.1.5040.1.2.17.3.2.1.1.4
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtPortOffset2 1.3.6.1.4.1.5040.1.2.17.3.2.1.1.5
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtPortTemperature2 1.3.6.1.4.1.5040.1.2.17.3.2.1.1.6
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtPortComment 1.3.6.1.4.1.5040.1.2.17.3.2.1.1.7
Offset calibration: informations of date, name of operator, reference devices.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtPortSensorSelect 1.3.6.1.4.1.5040.1.2.17.3.2.1.1.8
Binary coded options of the sensor: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : PT100 (default) Bit 1 : PT1000 Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtMfName 1.3.6.1.4.1.5040.1.2.17.3.3.1
Manufacturer company name
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtMfAddr 1.3.6.1.4.1.5040.1.2.17.3.3.2
Manufacturer address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtMfHotline 1.3.6.1.4.1.5040.1.2.17.3.3.3
Manufacturer hotline.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtMfInternet 1.3.6.1.4.1.5040.1.2.17.3.3.4
Manufacturer Internet address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtMfDeviceTyp 1.3.6.1.4.1.5040.1.2.17.3.3.5
Manufacturer device name (model number).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtMfOrderNo 1.3.6.1.4.1.5040.1.2.17.3.3.6
Manufacturer part number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtDiagErrorCount 1.3.6.1.4.1.5040.1.2.17.4.1
Number of entries in the error memory.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtDiagBinaryError 1.3.6.1.4.1.5040.1.2.17.4.2
Error causes coded bit-by-bit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtDiagErrorIndex 1.3.6.1.4.1.5040.1.2.17.4.3
The value of this variable is used as an index to read an error massege from wtWebioAn1GraphPtDiagErrorMessage. Errors are numbered from 1 to wtWebioAn1GraphPtDiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebioAn1GraphPtDiagErrorMessage.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtDiagErrorMessage 1.3.6.1.4.1.5040.1.2.17.4.4
Using wtWebioAn1GraphPtDiagErrorIndex as an index, the appropriate message is available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtDiagErrorClear 1.3.6.1.4.1.5040.1.2.17.4.5
Writing 1 into this variable clears all diagnosis messages.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtAlert1 31
This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphPtAlert2 32
This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphPtAlert3 33
This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphPtAlert4 34
This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphPtAlert5 35
This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphPtAlert6 36
This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphPtAlert7 37
This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphPtAlert8 38
This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphPtAlert9 91
This SNMP trap is generated when Alarm 1 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphPtAlert10 92
This SNMP trap is generated when Alarm 2 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphPtAlert11 93
This SNMP trap is generated when Alarm 3 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphPtAlert12 94
This SNMP trap is generated when Alarm 4 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphPtAlert13 95
This SNMP trap is generated when Alarm 5 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphPtAlert14 96
This SNMP trap is generated when Alarm 6 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphPtAlert15 97
This SNMP trap is generated when Alarm 7 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphPtAlert16 98
This SNMP trap is generated when Alarm 8 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphPtAlertDiag 110
This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphPtSwSensors 1.3.6.1.4.1.5040.1.2.23.1.1
Number of temperature sensors
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebioAn1GraphPtSwSensorTable 1.3.6.1.4.1.5040.1.2.23.1.2
List of sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioAn1GraphPtSwSensorEntry

wtWebioAn1GraphPtSwSensorEntry 1.3.6.1.4.1.5040.1.2.23.1.2.1
Temperature sensor numbers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioAn1GraphPtSwSensorEntry  

wtWebioAn1GraphPtSwSensorNo 1.3.6.1.4.1.5040.1.2.23.1.2.1.1
Temperature sensor number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebioAn1GraphPtSwTempValueTable 1.3.6.1.4.1.5040.1.2.23.1.3
List of temperature values corresponding to the channel numbers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioAn1GraphPtSwTempValueEntry

wtWebioAn1GraphPtSwTempValueEntry 1.3.6.1.4.1.5040.1.2.23.1.3.1
Temperatures of the sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioAn1GraphPtSwTempValueEntry  

wtWebioAn1GraphPtSwTempValue 1.3.6.1.4.1.5040.1.2.23.1.3.1.1
Temperature value of the sensor, ASCII, 5 characters in length.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(5)  

wtWebioAn1GraphPtSwBinaryTempValueTable 1.3.6.1.4.1.5040.1.2.23.1.4
List of binary temperature values corresponding to the channel numbers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioAn1GraphPtSwBinaryTempValueEntry

wtWebioAn1GraphPtSwBinaryTempValueEntry 1.3.6.1.4.1.5040.1.2.23.1.4.1
Binary temperature values of the sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioAn1GraphPtSwBinaryTempValueEntry  

wtWebioAn1GraphPtSwBinaryTempValue 1.3.6.1.4.1.5040.1.2.23.1.4.1.1
Binary temperature value of the sensor in 1/10 degrees Celsius, signed number, 0x7FFF indicates an invalid measured value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtSwOutputs 1.3.6.1.4.1.5040.1.2.23.1.5
Number of outputs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebioAn1GraphPtSwOutputTable 1.3.6.1.4.1.5040.1.2.23.1.6
List of outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioAn1GraphPtSwOutputEntry

wtWebioAn1GraphPtSwOutputEntry 1.3.6.1.4.1.5040.1.2.23.1.6.1
Output numbers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioAn1GraphPtSwSensorEntry  

wtWebioAn1GraphPtSwOutputNo 1.3.6.1.4.1.5040.1.2.23.1.6.1.1
Output number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1  

wtWebioAn1GraphPtSwBinaryOutputValueTable 1.3.6.1.4.1.5040.1.2.23.1.7
List of binary ouput values corresponding to the channel numbers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioAn1GraphPtSwBinaryOutputValueEntry

wtWebioAn1GraphPtSwBinaryOutputValueEntry 1.3.6.1.4.1.5040.1.2.23.1.7.1
Binary states of the outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioAn1GraphPtSwBinaryOutputValueEntry  

wtWebioAn1GraphPtSwBinaryOutputValue 1.3.6.1.4.1.5040.1.2.23.1.7.1.1
Binary state of the output.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtWebioAn1GraphPtSwBinaryOutput-OFF(0), wtWebioAn1GraphPtSwBinaryOutput-ON(1)  

wtWebioAn1GraphPtSwTempValuePktTable 1.3.6.1.4.1.5040.1.2.23.1.8
List of temperature values corresponding to the channel numbers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioAn1GraphPtSwTempValuePktEntry

wtWebioAn1GraphPtSwTempValuePktEntry 1.3.6.1.4.1.5040.1.2.23.1.8.1
Temperatures of the sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioAn1GraphPtSwTempValuePktEntry  

wtWebioAn1GraphPtSwTempValuePkt 1.3.6.1.4.1.5040.1.2.23.1.8.1.1
Temperature value of the sensor, ASCII, 5 characters in length, decimal point.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(5)  

wtWebioAn1GraphPtSwSessCntrlPassword 1.3.6.1.4.1.5040.1.2.23.2.1
Entering this password opens a session which is ended by writing a 1 to wtWebioAn1GraphPtSwSessCntrlLogout. When read this variable provides a string of length zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwSessCntrlConfigMode 1.3.6.1.4.1.5040.1.2.23.2.2
When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtWebioAn1GraphPtSwSessCntrl-NoSession(0), wtWebioAn1GraphPtSwSessCntrl-Session(1)  

wtWebioAn1GraphPtSwSessCntrlLogout 1.3.6.1.4.1.5040.1.2.23.2.3
If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtSwSessCntrlAdminPassword 1.3.6.1.4.1.5040.1.2.23.2.4
This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwSessCntrlConfigPassword 1.3.6.1.4.1.5040.1.2.23.2.5
This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwDeviceName 1.3.6.1.4.1.5040.1.2.23.3.1.1.1
Name of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwDeviceText 1.3.6.1.4.1.5040.1.2.23.3.1.1.2
Description of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwDeviceLocation 1.3.6.1.4.1.5040.1.2.23.3.1.1.3
Description of the location of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwDeviceContact 1.3.6.1.4.1.5040.1.2.23.3.1.1.4
Contact address of the system operator of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwTzOffsetHrs 1.3.6.1.4.1.5040.1.2.23.3.1.2.1.1
Offset hours for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtSwTzOffsetMin 1.3.6.1.4.1.5040.1.2.23.3.1.2.1.2
Offset minutes for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtSwTzEnable 1.3.6.1.4.1.5040.1.2.23.3.1.2.1.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtSwStTzOffsetHrs 1.3.6.1.4.1.5040.1.2.23.3.1.2.1.4
Offset hours of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtSwStTzOffsetMin 1.3.6.1.4.1.5040.1.2.23.3.1.2.1.5
Offset minutes of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtSwStTzEnable 1.3.6.1.4.1.5040.1.2.23.3.1.2.1.6
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtSwStTzStartMonth 1.3.6.1.4.1.5040.1.2.23.3.1.2.1.7
Month in which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioAn1GraphPtSwStartMonth-January(1), wtWebioAn1GraphPtSwStartMonth-February(2), wtWebioAn1GraphPtSwStartMonth-March(3), wtWebioAn1GraphPtSwStartMonth-April(4), wtWebioAn1GraphPtSwStartMonth-May(5), wtWebioAn1GraphPtSwStartMonth-June(6), wtWebioAn1GraphPtSwStartMonth-July(7), wtWebioAn1GraphPtSwStartMonth-August(8), wtWebioAn1GraphPtSwStartMonth-September(9), wtWebioAn1GraphPtSwStartMonth-October(10), wtWebioAn1GraphPtSwStartMonth-November(11), wtWebioAn1GraphPtSwStartMonth-December(12)  

wtWebioAn1GraphPtSwStTzStartMode 1.3.6.1.4.1.5040.1.2.23.3.1.2.1.8
Mode of the day of the week for which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioAn1GraphPtSwStartMode-first(1), wtWebioAn1GraphPtSwStartMode-second(2), wtWebioAn1GraphPtSwStartMode-third(3), wtWebioAn1GraphPtSwStartMode-fourth(4), wtWebioAn1GraphPtSwStartMode-last(5)  

wtWebioAn1GraphPtSwStTzStartWday 1.3.6.1.4.1.5040.1.2.23.3.1.2.1.9
Day of the week on which the change is made from winter time to summer time
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioAn1GraphPtSwStartWday-Sunday(1), wtWebioAn1GraphPtSwStartWday-Monday(2), wtWebioAn1GraphPtSwStartWday-Tuesday(3), wtWebioAn1GraphPtSwStartWday-Thursday(4), wtWebioAn1GraphPtSwStartWday-Wednesday(5), wtWebioAn1GraphPtSwStartWday-Friday(6), wtWebioAn1GraphPtSwStartWday-Saturday(7)  

wtWebioAn1GraphPtSwStTzStartHrs 1.3.6.1.4.1.5040.1.2.23.3.1.2.1.10
Hour in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtSwStTzStartMin 1.3.6.1.4.1.5040.1.2.23.3.1.2.1.11
Minute in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtSwStTzStopMonth 1.3.6.1.4.1.5040.1.2.23.3.1.2.1.12
Month in which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioAn1GraphPtSwStopMonth-January(1), wtWebioAn1GraphPtSwStopMonth-February(2), wtWebioAn1GraphPtSwStopMonth-March(3), wtWebioAn1GraphPtSwStopMonth-April(4), wtWebioAn1GraphPtSwStopMonth-May(5), wtWebioAn1GraphPtSwStopMonth-June(6), wtWebioAn1GraphPtSwStopMonth-July(7), wtWebioAn1GraphPtSwStopMonth-August(8), wtWebioAn1GraphPtSwStopMonth-September(9), wtWebioAn1GraphPtSwStopMonth-October(10), wtWebioAn1GraphPtSwStopMonth-November(11), wtWebioAn1GraphPtSwStopMonth-December(12)  

wtWebioAn1GraphPtSwStTzStopMode 1.3.6.1.4.1.5040.1.2.23.3.1.2.1.13
Mode of the week day on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioAn1GraphPtSwStopMode-first(1), wtWebioAn1GraphPtSwStopMode-second(2), wtWebioAn1GraphPtSwStopMode-third(3), wtWebioAn1GraphPtSwStopMode-fourth(4), wtWebioAn1GraphPtSwStopMode-last(5)  

wtWebioAn1GraphPtSwStTzStopWday 1.3.6.1.4.1.5040.1.2.23.3.1.2.1.14
Day of the week on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioAn1GraphPtSwStopWday-Sunday(1), wtWebioAn1GraphPtSwStopWday-Monday(2), wtWebioAn1GraphPtSwStopWday-Tuesday(3), wtWebioAn1GraphPtSwStopWday-Thursday(4), wtWebioAn1GraphPtSwStopWday-Wednesday(5), wtWebioAn1GraphPtSwStopWday-Friday(6), wtWebioAn1GraphPtSwStopWday-Saturday(7)  

wtWebioAn1GraphPtSwStTzStopHrs 1.3.6.1.4.1.5040.1.2.23.3.1.2.1.15
Hour at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtSwStTzStopMin 1.3.6.1.4.1.5040.1.2.23.3.1.2.1.16
Minute at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtSwTimeServer1 1.3.6.1.4.1.5040.1.2.23.3.1.2.2.1
IP address or name of the 1st time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwTimeServer2 1.3.6.1.4.1.5040.1.2.23.3.1.2.2.2
IP address or name of the 2nd time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwTsEnable 1.3.6.1.4.1.5040.1.2.23.3.1.2.2.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtSwTsSyncTime 1.3.6.1.4.1.5040.1.2.23.3.1.2.2.4
Daily synchronisation time with the time server (hour: 0-23).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtSwClockHrs 1.3.6.1.4.1.5040.1.2.23.3.1.2.3.1
Clock hours taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..23  

wtWebioAn1GraphPtSwClockMin 1.3.6.1.4.1.5040.1.2.23.3.1.2.3.2
Clock minutes taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..59  

wtWebioAn1GraphPtSwClockDay 1.3.6.1.4.1.5040.1.2.23.3.1.2.3.3
Date: Day of the month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..31  

wtWebioAn1GraphPtSwClockMonth 1.3.6.1.4.1.5040.1.2.23.3.1.2.3.4
Date: Month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioAn1GraphPtSwClockMonth-January(1), wtWebioAn1GraphPtSwClockMonth-February(2), wtWebioAn1GraphPtSwClockMonth-March(3), wtWebioAn1GraphPtSwClockMonth-April(4), wtWebioAn1GraphPtSwClockMonth-May(5), wtWebioAn1GraphPtSwClockMonth-June(6), wtWebioAn1GraphPtSwClockMonth-July(7), wtWebioAn1GraphPtSwClockMonth-August(8), wtWebioAn1GraphPtSwClockMonth-September(9), wtWebioAn1GraphPtSwClockMonth-October(10), wtWebioAn1GraphPtSwClockMonth-November(11), wtWebioAn1GraphPtSwClockMonth-December(12)  

wtWebioAn1GraphPtSwClockYear 1.3.6.1.4.1.5040.1.2.23.3.1.2.3.5
Date: Year, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebioAn1GraphPtSwIpAddress 1.3.6.1.4.1.5040.1.2.23.3.1.3.1.1
IP address of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioAn1GraphPtSwSubnetMask 1.3.6.1.4.1.5040.1.2.23.3.1.3.1.2
Subnet mask of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioAn1GraphPtSwGateway 1.3.6.1.4.1.5040.1.2.23.3.1.3.1.3
Gateway of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioAn1GraphPtSwDnsServer1 1.3.6.1.4.1.5040.1.2.23.3.1.3.1.4
IP address of the 1st DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwDnsServer2 1.3.6.1.4.1.5040.1.2.23.3.1.3.1.5
IP address of the 2nd DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwAddConfig 1.3.6.1.4.1.5040.1.2.23.3.1.3.1.6
Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP disable Bit 0: BOOTP disable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwStartup 1.3.6.1.4.1.5040.1.2.23.3.1.3.2.1
Binary coded start page: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: Index.htm Bit 2: Home.htm Bit 3: User.htm Only one page may be selected at a time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwGetHeaderEnable 1.3.6.1.4.1.5040.1.2.23.3.1.3.2.2
If these bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device and/or a HTTP header: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-6: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwHttpPort 1.3.6.1.4.1.5040.1.2.23.3.1.3.2.3
Definition of the standard HTML port (Default: 80).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioAn1GraphPtSwMailAdName 1.3.6.1.4.1.5040.1.2.23.3.1.3.3.1
Device name for mail administration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwMailReply 1.3.6.1.4.1.5040.1.2.23.3.1.3.3.2
Reply address for the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwMailServer 1.3.6.1.4.1.5040.1.2.23.3.1.3.3.3
Name or IP address of the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1MailEnable 1.3.6.1.4.1.5040.1.2.23.3.1.3.3.4
Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwMailAuthentication 1.3.6.1.4.1.5040.1.2.23.3.1.3.3.5
Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtSwMailAuthUser 1.3.6.1.4.1.5040.1.2.23.3.1.3.3.6
Name of the user to be authenticated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwMailAuthPassword 1.3.6.1.4.1.5040.1.2.23.3.1.3.3.7
Authentication password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwMailPop3Server 1.3.6.1.4.1.5040.1.2.23.3.1.3.3.8
Name or Ip-address of the POP3 Servers.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwSnmpCommunityStringRead 1.3.6.1.4.1.5040.1.2.23.3.1.3.4.1
Community string read only
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwSnmpCommunityStringReadWrite 1.3.6.1.4.1.5040.1.2.23.3.1.3.4.2
Community string read / write
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwSystemTrapManagerIP 1.3.6.1.4.1.5040.1.2.23.3.1.3.4.3
Name or IP address of the TCP server which accepts the system trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwSystemTrapEnable 1.3.6.1.4.1.5040.1.2.23.3.1.3.4.4
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtSwSnmpEnable 1.3.6.1.4.1.5040.1.2.23.3.1.3.4.5
Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwSnmpCommunityStringTrap 1.3.6.1.4.1.5040.1.2.23.3.1.3.4.6
Community string send within traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwUdpPort 1.3.6.1.4.1.5040.1.2.23.3.1.3.5.1
Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioAn1GraphPtSwUdpEnable 1.3.6.1.4.1.5040.1.2.23.3.1.3.5.2
Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwSyslogServerIP 1.3.6.1.4.1.5040.1.2.23.3.1.3.6.1
Name or IP address of the Syslog server, which accepts the Syslog messgaes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwSyslogServerPort 1.3.6.1.4.1.5040.1.2.23.3.1.3.6.2
Portnumber of the Syslog servers, default 514.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtSwSyslogSystemMessagesEnable 1.3.6.1.4.1.5040.1.2.23.3.1.3.6.3
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtSwSyslogEnable 1.3.6.1.4.1.5040.1.2.23.3.1.3.6.4
Set bit 0 to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwFTPServerIP 1.3.6.1.4.1.5040.1.2.23.3.1.3.7.1
Name or IP address of the FTP server, which accepts the FTP messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwFTPServerControlPort 1.3.6.1.4.1.5040.1.2.23.3.1.3.7.2
Portnumber of the control port of the FTP server, default 21.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtSwFTPUserName 1.3.6.1.4.1.5040.1.2.23.3.1.3.7.3
FTP Loggin: user name.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwFTPPassword 1.3.6.1.4.1.5040.1.2.23.3.1.3.7.4
FTP Loggin: user password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwFTPAccount 1.3.6.1.4.1.5040.1.2.23.3.1.3.7.5
FTP Loggin: name of account.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwFTPOption 1.3.6.1.4.1.5040.1.2.23.3.1.3.7.6
Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwFTPEnable 1.3.6.1.4.1.5040.1.2.23.3.1.3.7.7
Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwLanguageSelect 1.3.6.1.4.1.5040.1.2.23.3.1.3.9.1
Language selection: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2-7: unused Bit 1 : English Bit 0 : German
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwLoggerTimebase 1.3.6.1.4.1.5040.1.2.23.3.1.4.1
Time base of the data logger
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioAn1GraphPtSwDatalogger-1Min(1), wtWebioAn1GraphPtSwDatalogger-5Min(2), wtWebioAn1GraphPtSwDatalogger-15Min(3), wtWebioAn1GraphPtSwDatalogger-60Min(4)  

wtWebioAn1GraphPtSwLoggerSensorSel 1.3.6.1.4.1.5040.1.2.23.3.1.4.2
Binary coded sensor / output selection: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Output 1 Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtSwDisplaySensorSel 1.3.6.1.4.1.5040.1.2.23.3.1.4.3
Binary coded sensor selection: only selected sensors / outputs will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Output 1 Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtSwSensorColorTable 1.3.6.1.4.1.5040.1.2.23.3.1.4.4
List of sensor colors for the praphical presentation.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioAn1GraphPtSwSensorColorEntry

wtWebioAn1GraphPtSwSensorColorEntry 1.3.6.1.4.1.5040.1.2.23.3.1.4.4.1
Index numbers of the sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioAn1GraphPtSwSensorColorEntry  

wtWebioAn1GraphPtSwSensorColor 1.3.6.1.4.1.5040.1.2.23.3.1.4.4.1.1
Color of the sensors at the praphical presention.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(3)  

wtWebioAn1GraphPtSwAutoScaleEnable 1.3.6.1.4.1.5040.1.2.23.3.1.4.5
If bit 0 is set, vertical auto scale is enabled: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Auto Scale enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwVerticalUpperLimit 1.3.6.1.4.1.5040.1.2.23.3.1.4.6
This value defines the maximum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwVerticalLowerLimit 1.3.6.1.4.1.5040.1.2.23.3.1.4.7
This value defines the minimum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwHorizontalZoom 1.3.6.1.4.1.5040.1.2.23.3.1.4.8
Defines the default zoom stage, if no auto scaling is selected.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebioAn1GraphPtSwZoom-25min(1), wtWebioAn1GraphPtSwZoom-75min(2), wtWebioAn1GraphPtSwZoom-5hrs(3), wtWebioAn1GraphPtSwZoom-30hrs(4), wtWebioAn1GraphPtSwZoom-5days(5), wtWebioAn1GraphPtSwZoom-25days(6)  

wtWebioAn1GraphPtSwAlarmCount 1.3.6.1.4.1.5040.1.2.23.3.1.5.1
Number of independent alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..8  

wtWebioAn1GraphPtSwAlarmIfTable 1.3.6.1.4.1.5040.1.2.23.3.1.5.2
List of alarm indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioAn1GraphPtSwAlarmIfEntry

wtWebioAn1GraphPtSwAlarmIfEntry 1.3.6.1.4.1.5040.1.2.23.3.1.5.2.1
Numbers of the alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioAn1GraphPtSwAlarmIfEntry  

wtWebioAn1GraphPtSwAlarmNo 1.3.6.1.4.1.5040.1.2.23.3.1.5.2.1.1
Alarm number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..8  

wtWebioAn1GraphPtSwAlarmTable 1.3.6.1.4.1.5040.1.2.23.3.1.5.3
List of settings depending on the alarm number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioAn1GraphPtSwAlarmEntry

wtWebioAn1GraphPtSwAlarmEntry 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1
Alarm parameters of the individual alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioAn1GraphPtSwAlarmEntry  

wtWebioAn1GraphPtSwAlarmTrigger 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.1
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: Bit 0 : Timer Bit 1 : ColdStart Bit 2 : WarmStart Bit 3 : Sensor lost Bit 4-7: unused Octet 4: Bit 0 : Sensor 1 Bit 1-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtSwAlarmMin 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.2
Minimum temperature in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwAlarmMax 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.3
Maximum temperature in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwAlarmHysteresis 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.4
Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.) , in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwAlarmDelay 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.5
Alarm will be delayed by setting this time while stable alarm condition occur (time in minutes).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwAlarmInterval 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.6
Send interval for alarm messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwAlarmEnable 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.7
Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Output switch enable Bit 1 : Mail Enable Bit 2 : SNMP Trap enable Bit 3 : TCP Client enable Bit 4 : Syslog Messages enable Bit 5 : FTP enable Bit 6-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtSwAlarmEMailAddr 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.8
E-Mail address for sending the alarm mail to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwAlarmMailSubject 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.9
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwAlarmMailText 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.10
Alarm mail text: provides the current temperature; n = 1..8. provides the current time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwAlarmManagerIP 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.11
Name or IP address of the SNMP Manager which accepts the trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwAlarmTrapText 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.12
This text is sent in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwAlarmMailOptions 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.13
Binary coded options: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtSwAlarmTcpIpAddr 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.14
Name or IP address of the TCP server which accepts the trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwAlarmTcpPort 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.15
Port number of the TCP server which accepts the trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioAn1GraphPtSwAlarmTcpText 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.16
This text is sent in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwAlarmClearMailSubject 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.17
Subject line for alarm clear mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwAlarmClearMailText 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.18
Alarm clear mail text: provides the current temperature; n = 1..8. provides the current time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwAlarmClearTrapText 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.19
This text is sent in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwAlarmClearTcpText 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.20
This text is sent in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwAlarmSyslogIpAddr 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.21
IP address of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebioAn1GraphPtSwAlarmSyslogPort 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.22
Port number of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioAn1GraphPtSwAlarmSyslogText 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.23
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwAlarmSyslogClearText 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.24
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwAlarmFtpDataPort 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.25
Local data port: 1..65535 or AUTO: the next free port will be assigned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwAlarmFtpFileName 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.26
Name of the file including path informations.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwAlarmFtpText 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.27
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwAlarmFtpClearText 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.28
Alarm clear message to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwAlarmFtpOptions 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.29
Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtSwAlarmTimerCron 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.30
This entry contains 5 text fields space or tab seperated for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separately. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwAlarmDeltaTemp 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.31
Maximum rate of change degrees/min with maximum 2 decimal places. Compared with the average of a period of 5 minutes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwAlarmName 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.39
Alert name
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwAlarmActive 1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.40
Alert active 1 = ON 0 = OFF
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwGraphicsBaseEnable 1.3.6.1.4.1.5040.1.2.23.3.1.6.1.1
Defines the viewing options of the graphic: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Auto scroll enable Bit 1 : Show table Bit 2 : Show graph Bit 3 : Show control buttons Bit 4 : Show config menu Bit 5 : Show alarm monitor Bit 6-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwGraphicsBaseWidth 1.3.6.1.4.1.5040.1.2.23.3.1.6.1.2
Defines the width of the graphic in pixels.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtSwGraphicsBaseHeight 1.3.6.1.4.1.5040.1.2.23.3.1.6.1.3
Defines the height of the graphic in pixels.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtSwGraphicsBaseFrameColor 1.3.6.1.4.1.5040.1.2.23.3.1.6.1.4
Frame color definition in RGB.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(3)  

wtWebioAn1GraphPtSwGraphicsBaseBackgroundColor 1.3.6.1.4.1.5040.1.2.23.3.1.6.1.5
Background color definition in RGB.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(3)  

wtWebioAn1GraphPtSwGraphicsBasePollingrate 1.3.6.1.4.1.5040.1.2.23.3.1.6.1.6
Defines the pollingrate in seconds, which defines the refreshing intervall of the graphic.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtSwGraphicsSelectDisplaySensorSel 1.3.6.1.4.1.5040.1.2.23.3.1.6.2.1
Binary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Sensor 1 Bit 1-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtSwGraphicsSelectDisplayShowExtrem 1.3.6.1.4.1.5040.1.2.23.3.1.6.2.2
Binary coded sensor selection: only selected sensors will be shown with minima and maxima: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Sensor 1 Bit 1-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtSw2SensorColorTable 1.3.6.1.4.1.5040.1.2.23.3.1.6.2.3
List of sensor colors for the praphical presentation.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioAn1GraphPtSw2SensorColorEntry

wtWebioAn1GraphPtSw2SensorColorEntry 1.3.6.1.4.1.5040.1.2.23.3.1.6.2.3.1
Numbers of the sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioAn1GraphPtSw2SensorColorEntry  

wtWebioAn1GraphPtSw2GraphicsSensorColor 1.3.6.1.4.1.5040.1.2.23.3.1.6.2.3.1.1
Color of the sensors at the praphical presention.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(3)  

wtWebioAn1GraphPtSw2GraphicsSelectScale 1.3.6.1.4.1.5040.1.2.23.3.1.6.2.3.1.2
Assignes one of 4 scales to a sensor: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Use Scale 1 Bit 1-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwGraphicsScaleAutoScaleEnable 1.3.6.1.4.1.5040.1.2.23.3.1.6.3.1
Select the Auto Scale Mode: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto scale enable Bit 1-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwGraphicsScaleAutoFitEnable 1.3.6.1.4.1.5040.1.2.23.3.1.6.3.2
Select the Auto Fit Mode:: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto fit enable Bit 1-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwGraphicsScale1Min 1.3.6.1.4.1.5040.1.2.23.3.1.6.3.3
Scale 1: Minimum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtSwGraphicsScale2Min 1.3.6.1.4.1.5040.1.2.23.3.1.6.3.4
Scale 2: Minimum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtSwGraphicsScale3Min 1.3.6.1.4.1.5040.1.2.23.3.1.6.3.5
Scale 3: Minimum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtSwGraphicsScale4Min 1.3.6.1.4.1.5040.1.2.23.3.1.6.3.6
Scale 4: Minimum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtSwGraphicsScale1Max 1.3.6.1.4.1.5040.1.2.23.3.1.6.3.7
Scale 1: Maximum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtSwGraphicsScale2Max 1.3.6.1.4.1.5040.1.2.23.3.1.6.3.8
Scale 2: Maximum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtSwGraphicsScale3Max 1.3.6.1.4.1.5040.1.2.23.3.1.6.3.9
Scale 3: Maximum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtSwGraphicsScale4Max 1.3.6.1.4.1.5040.1.2.23.3.1.6.3.10
Scale 4: Maximum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtSwGraphicsScale1Unit 1.3.6.1.4.1.5040.1.2.23.3.1.6.3.11
Scale 1: Unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwGraphicsScale2Unit 1.3.6.1.4.1.5040.1.2.23.3.1.6.3.12
Scale 2: Unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwGraphicsScale3Unit 1.3.6.1.4.1.5040.1.2.23.3.1.6.3.13
Scale 3: Unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwGraphicsScale4Unit 1.3.6.1.4.1.5040.1.2.23.3.1.6.3.14
Scale 4: Unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwReportCount 1.3.6.1.4.1.5040.1.2.23.3.1.7.1
Number of independent Reports.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..8  

wtWebioAn1GraphPtSwReportIfTable 1.3.6.1.4.1.5040.1.2.23.3.1.7.2
List of Report indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioAn1GraphPtSwReportIfEntry

wtWebioAn1GraphPtSwReportIfEntry 1.3.6.1.4.1.5040.1.2.23.3.1.7.2.1
Numbers of the Reports.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioAn1GraphPtSwReportIfEntry  

wtWebioAn1GraphPtSwReportNo 1.3.6.1.4.1.5040.1.2.23.3.1.7.2.1.1
Report number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtSwReportTable 1.3.6.1.4.1.5040.1.2.23.3.1.7.3
List of settings depending on the Report number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioAn1GraphPtSwReportEntry

wtWebioAn1GraphPtSwReportEntry 1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1
Report parameters of the individual Reports.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioAn1GraphPtSwReportEntry  

wtWebioAn1GraphPtSwReportEnable 1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.1
Binr kodierte Triggerbedingungen: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Report enable Bit 1-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtSwReportTimerCron 1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.2
This entry defines a time window for alarm 1-8 and a activation time for the report. A time window is definied by start and stop time stamp, seperated by a space or tab. The activation time of the report is defined by a single start time stamp. Each time stamp contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger an action, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas (i.e.: 2,14,22) - a partition within the allowed range (i.e.: 1-5) - step size within a partition of the allowed range (i.e.: 0-59/2 every second minute).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwReportMethodeEnable 1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.3
Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable Bit 3: Syslog enable Bit 4: FTP Client enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtSwReportEMailAddr 1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.8
E-Mail address for sending the alarm mail to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwReportMailSubject 1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.9
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwReportMailText 1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.10
Report mail text: provides the current temperature; n = 1..2. provides the current time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwReportManagerIP 1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.11
Name or IP address of the SNMP Manager which accepts the trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwReportTrapText 1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.12
This text is sent in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwReportMailOptions 1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.13
Binary coded options: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Logger.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtSwReportTcpIpAddr 1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.14
Name or IP address of the TCP server which accepts the trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwReportTcpPort 1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.15
Port number of the TCP server which accepts the trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioAn1GraphPtSwReportTcpText 1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.16
This text is sent in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwReportClearMailSubject 1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.17
Subject line for alarm clear mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwReportClearMailText 1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.18
Report clear mail text: provides the current temperature; n = 1..2. provides the current time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwReportClearTrapText 1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.19
This text is sent in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwReportClearTcpText 1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.20
This text is sent in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwReportSyslogIpAddr 1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.24
IP address of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwReportSyslogPort 1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.25
Port number of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebioAn1GraphPtSwReportSyslogText 1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.26
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwReportSyslogClearText 1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.27
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body of a alarm clear message.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwReportFtpDataPort 1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.28
Local data port: 1..65535 or AUTO: the next free port will be assigned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwReportFtpFileName 1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.29
Name of the file including path informations.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwReportFtpText 1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.30
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwReportFtpClearText 1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.31
Report clear message to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwReportFtpOption 1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.32
Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtSwPortTable 1.3.6.1.4.1.5040.1.2.23.3.2.1
List of settings depending on the sensor number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioAn1GraphPtSwPortEntry

wtWebioAn1GraphPtSwPortEntry 1.3.6.1.4.1.5040.1.2.23.3.2.1.1
Sensor parameters for the individual sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioAn1GraphPtSwPortEntry  

wtWebioAn1GraphPtSwPortName 1.3.6.1.4.1.5040.1.2.23.3.2.1.1.1
Name of the sensor.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwPortText 1.3.6.1.4.1.5040.1.2.23.3.2.1.1.2
Description of the sensor.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwPortOffset1 1.3.6.1.4.1.5040.1.2.23.3.2.1.1.3
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwPortTemperature1 1.3.6.1.4.1.5040.1.2.23.3.2.1.1.4
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwPortOffset2 1.3.6.1.4.1.5040.1.2.23.3.2.1.1.5
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwPortTemperature2 1.3.6.1.4.1.5040.1.2.23.3.2.1.1.6
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwPortComment 1.3.6.1.4.1.5040.1.2.23.3.2.1.1.7
Offset calibration: informations of date, name of operator, reference devices.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwPortSensorSelect 1.3.6.1.4.1.5040.1.2.23.3.2.1.1.8
Binary coded options of the sensor: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : PT100 (default) Bit 1 : PT1000 Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtSwPortSensorUnit 1.3.6.1.4.1.5040.1.2.23.3.2.1.1.9
Binary coded options of the sensor: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Celsius (default) Bit 1 : Fahrenheit Bit 2 : Kelvin Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtSwPortOutputTable 1.3.6.1.4.1.5040.1.2.23.3.2.3
List of settings depending on the sensor number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebioAn1GraphPtSwPortOutputEntry

wtWebioAn1GraphPtSwPortOutputEntry 1.3.6.1.4.1.5040.1.2.23.3.2.3.1
Parameters for the individual outputs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebioAn1GraphPtSwPortOutputEntry  

wtWebioAn1GraphPtSwPortOutputName 1.3.6.1.4.1.5040.1.2.23.3.2.3.1.1
Name of the output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwPortOutputText 1.3.6.1.4.1.5040.1.2.23.3.2.3.1.2
Description of the output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwPortOutputPolarity 1.3.6.1.4.1.5040.1.2.23.3.2.3.1.3
Binary coded options of the output: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Normally open (default) Bit 1 : Normally closed Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtSwPortOutputComment 1.3.6.1.4.1.5040.1.2.23.3.2.3.1.4
Additional informations of date, name of operator, reference devices.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPortOutputResetEnable 1.3.6.1.4.1.5040.1.2.23.3.2.3.1.5
Binary coded options of the output: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Manual Reset enable (default off) Bit 1-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebioAn1GraphPtSwMfName 1.3.6.1.4.1.5040.1.2.23.3.3.1
Manufacturer company name
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwMfAddr 1.3.6.1.4.1.5040.1.2.23.3.3.2
Manufacturer address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwMfHotline 1.3.6.1.4.1.5040.1.2.23.3.3.3
Manufacturer hotline.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwMfInternet 1.3.6.1.4.1.5040.1.2.23.3.3.4
Manufacturer Internet address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwMfDeviceTyp 1.3.6.1.4.1.5040.1.2.23.3.3.5
Manufacturer device name (model number).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwMfOrderNo 1.3.6.1.4.1.5040.1.2.23.3.3.6
Manufacturer part number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwDiagErrorCount 1.3.6.1.4.1.5040.1.2.23.4.1
Number of entries in the error memory.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtSwDiagBinaryError 1.3.6.1.4.1.5040.1.2.23.4.2
Error causes coded bit-by-bit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwDiagErrorIndex 1.3.6.1.4.1.5040.1.2.23.4.3
The value of this variable is used as an index to read an error massege from wtWebioAn1GraphPtSwDiagErrorMessage. Errors are numbered from 1 to wtWebioAn1GraphPtSwDiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebioAn1GraphPtSwDiagErrorMessage.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtSwDiagErrorMessage 1.3.6.1.4.1.5040.1.2.23.4.4
Using wtWebioAn1GraphPtSwDiagErrorIndex as an index, the appropriate message is available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1GraphPtSwDiagErrorClear 1.3.6.1.4.1.5040.1.2.23.4.5
Writing 1 into this variable clears all diagnosis messages.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER  

wtWebioAn1GraphPtSwAlert1 31
This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphPtSwAlert2 32
This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphPtSwAlert3 33
This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphPtSwAlert4 34
This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphPtSwAlert5 35
This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphPtSwAlert6 36
This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphPtSwAlert7 37
This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphPtSwAlert8 38
This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphPtSwAlert9 91
This SNMP trap is generated when Alarm 1 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphPtSwAlert10 92
This SNMP trap is generated when Alarm 2 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphPtSwAlert11 93
This SNMP trap is generated when Alarm 3 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphPtSwAlert12 94
This SNMP trap is generated when Alarm 4 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphPtSwAlert13 95
This SNMP trap is generated when Alarm 5 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphPtSwAlert14 96
This SNMP trap is generated when Alarm 6 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphPtSwAlert15 97
This SNMP trap is generated when Alarm 7 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphPtSwAlert16 98
This SNMP trap is generated when Alarm 8 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebioAn1GraphPtSwAlertDiag 110
This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE