WebGraph-Thermo-Hygro-Barometer-US-MIB

File: WebGraph-Thermo-Hygro-Barometer-US-MIB.mib (84510 bytes)

Imported modules

RFC-1212 RFC-1215 RFC1213-MIB
RFC1155-SMI

Imported symbols

OBJECT-TYPE TRAP-TYPE DisplayString
PhysAddress enterprises TimeTicks
IpAddress NetworkAddress

Defined Types

WtWebGraphThermoBaroSensorEntry  
SEQUENCE    
  wtWebGraphThermoBaroSensorNo INTEGER

WtWebGraphThermoBaroTempValueEntry  
SEQUENCE    
  wtWebGraphThermoBaroTempValue OCTET STRING

WtWebGraphThermoBaroBinaryTempValueEntry  
SEQUENCE    
  wtWebGraphThermoBaroBinaryTempValue INTEGER

WtWebGraphThermoBaroTempValuePktEntry  
SEQUENCE    
  wtWebGraphThermoBaroTempValuePkt OCTET STRING

WtWebGraphThermoBaroAlarmIfEntry  
SEQUENCE    
  wtWebGraphThermoBaroAlarmNo INTEGER

WtWebGraphThermoBaroAlarmEntry  
SEQUENCE    
  wtWebGraphThermoBaroAlarmTrigger OCTET STRING
  wtWebGraphThermoBaroAlarmMin OCTET STRING
  wtWebGraphThermoBaroAlarmMax OCTET STRING
  wtWebGraphThermoBaroAlarmHysteresis OCTET STRING
  wtWebGraphThermoBaroAlarmDelay OCTET STRING
  wtWebGraphThermoBaroAlarmInterval OCTET STRING
  wtWebGraphThermoBaroAlarmEnable OCTET STRING
  wtWebGraphThermoBaroAlarmEMailAddr OCTET STRING
  wtWebGraphThermoBaroAlarmMailSubject OCTET STRING
  wtWebGraphThermoBaroAlarmMailText OCTET STRING
  wtWebGraphThermoBaroAlarmManagerIP OCTET STRING
  wtWebGraphThermoBaroAlarmTrapText OCTET STRING
  wtWebGraphThermoBaroAlarmMailOptions OCTET STRING
  wtWebGraphThermoBaroAlarmTcpIpAddr OCTET STRING
  wtWebGraphThermoBaroAlarmTcpPort INTEGER
  wtWebGraphThermoBaroAlarmTcpText OCTET STRING
  wtWebGraphThermoBaroAlarmClearMailSubject OCTET STRING
  wtWebGraphThermoBaroAlarmClearMailText OCTET STRING
  wtWebGraphThermoBaroAlarmClearTrapText OCTET STRING
  wtWebGraphThermoBaroAlarmClearTcpText OCTET STRING
  wtWebGraphThermoBaroAlarmDeltaTemp OCTET STRING
  wtWebGraphThermoBaroAlarmRHMin OCTET STRING
  wtWebGraphThermoBaroAlarmRHMax OCTET STRING
  wtWebGraphThermoBaroAlarmRHHysteresis OCTET STRING
  wtWebGraphThermoBaroAlarmAHMin OCTET STRING
  wtWebGraphThermoBaroAlarmAHMax OCTET STRING
  wtWebGraphThermoBaroAlarmSyslogIpAddr OCTET STRING
  wtWebGraphThermoBaroAlarmSyslogPort INTEGER
  wtWebGraphThermoBaroAlarmSyslogText OCTET STRING
  wtWebGraphThermoBaroAlarmSyslogClearText OCTET STRING
  wtWebGraphThermoBaroAlarmFtpDataPort OCTET STRING
  wtWebGraphThermoBaroAlarmFtpFileName OCTET STRING
  wtWebGraphThermoBaroAlarmFtpText OCTET STRING
  wtWebGraphThermoBaroAlarmFtpClearText OCTET STRING
  wtWebGraphThermoBaroAlarmFtpOption OCTET STRING
  wtWebGraphThermoBaroAlarmTimerCron OCTET STRING
  wtWebGraphThermoBaroAlarmName OCTET STRING
  wtWebGraphThermoBaroAlarmActive OCTET STRING

WtWebGraphThermoBaroSensorColorEntry  
SEQUENCE    
  wtWebGraphThermoBaroGraphicsSensorColor OCTET STRING
  wtWebGraphThermoBaroGraphicsSelectScale OCTET STRING

WtWebGraphThermoBaroPortEntry  
SEQUENCE    
  wtWebGraphThermoBaroPortName OCTET STRING
  wtWebGraphThermoBaroPortText OCTET STRING
  wtWebGraphThermoBaroPortOffset1 OCTET STRING
  wtWebGraphThermoBaroPortTemperature1 OCTET STRING
  wtWebGraphThermoBaroPortOffset2 OCTET STRING
  wtWebGraphThermoBaroPortTemperature2 OCTET STRING
  wtWebGraphThermoBaroPortComment OCTET STRING

Defined Values

wut 1.3.6.1.4.1.5040
OBJECT IDENTIFIER    

wtComServer 1.3.6.1.4.1.5040.1
OBJECT IDENTIFIER    

wtWebio 1.3.6.1.4.1.5040.1.2
OBJECT IDENTIFIER    

wtWebGraphThermoBaro 1.3.6.1.4.1.5040.1.2.37
OBJECT IDENTIFIER    

wtWebGraphThermoBaroTemp 1.3.6.1.4.1.5040.1.2.37.1
OBJECT IDENTIFIER    

wtWebGraphThermoBaroSessCntrl 1.3.6.1.4.1.5040.1.2.37.2
OBJECT IDENTIFIER    

wtWebGraphThermoBaroConfig 1.3.6.1.4.1.5040.1.2.37.3
OBJECT IDENTIFIER    

wtWebGraphThermoBaroDiag 1.3.6.1.4.1.5040.1.2.37.4
OBJECT IDENTIFIER    

wtWebGraphThermoBaroDevice 1.3.6.1.4.1.5040.1.2.37.3.1
OBJECT IDENTIFIER    

wtWebGraphThermoBaroPorts 1.3.6.1.4.1.5040.1.2.37.3.2
OBJECT IDENTIFIER    

wtWebGraphThermoBaroManufact 1.3.6.1.4.1.5040.1.2.37.3.3
OBJECT IDENTIFIER    

wtWebGraphThermoBaroText 1.3.6.1.4.1.5040.1.2.37.3.1.1
OBJECT IDENTIFIER    

wtWebGraphThermoBaroTimeDate 1.3.6.1.4.1.5040.1.2.37.3.1.2
OBJECT IDENTIFIER    

wtWebGraphThermoBaroBasic 1.3.6.1.4.1.5040.1.2.37.3.1.3
OBJECT IDENTIFIER    

wtWebGraphThermoBaroDatalogger 1.3.6.1.4.1.5040.1.2.37.3.1.4
OBJECT IDENTIFIER    

wtWebGraphThermoBaroAlarm 1.3.6.1.4.1.5040.1.2.37.3.1.5
OBJECT IDENTIFIER    

wtWebGraphThermoBaroGraphics 1.3.6.1.4.1.5040.1.2.37.3.1.6
OBJECT IDENTIFIER    

wtWebGraphThermoBaroTimeZone 1.3.6.1.4.1.5040.1.2.37.3.1.2.1
OBJECT IDENTIFIER    

wtWebGraphThermoBaroTimeServer 1.3.6.1.4.1.5040.1.2.37.3.1.2.2
OBJECT IDENTIFIER    

wtWebGraphThermoBaroDeviceClock 1.3.6.1.4.1.5040.1.2.37.3.1.2.3
OBJECT IDENTIFIER    

wtWebGraphThermoBaroNetwork 1.3.6.1.4.1.5040.1.2.37.3.1.3.1
OBJECT IDENTIFIER    

wtWebGraphThermoBaroHTTP 1.3.6.1.4.1.5040.1.2.37.3.1.3.2
OBJECT IDENTIFIER    

wtWebGraphThermoBaroMail 1.3.6.1.4.1.5040.1.2.37.3.1.3.3
OBJECT IDENTIFIER    

wtWebGraphThermoBaroSNMP 1.3.6.1.4.1.5040.1.2.37.3.1.3.4
OBJECT IDENTIFIER    

wtWebGraphThermoBaroUDP 1.3.6.1.4.1.5040.1.2.37.3.1.3.5
OBJECT IDENTIFIER    

wtWebGraphThermoBaroSyslog 1.3.6.1.4.1.5040.1.2.37.3.1.3.6
OBJECT IDENTIFIER    

wtWebGraphThermoBaroFTP 1.3.6.1.4.1.5040.1.2.37.3.1.3.7
OBJECT IDENTIFIER    

wtWebGraphThermoBaroRSS 1.3.6.1.4.1.5040.1.2.37.3.1.3.8
OBJECT IDENTIFIER    

wtWebGraphThermoBaroLanguage 1.3.6.1.4.1.5040.1.2.37.3.1.3.9
OBJECT IDENTIFIER    

wtWebGraphThermoBaroGraphicsBase 1.3.6.1.4.1.5040.1.2.37.3.1.6.1
OBJECT IDENTIFIER    

wtWebGraphThermoBaroGraphicsSelect 1.3.6.1.4.1.5040.1.2.37.3.1.6.2
OBJECT IDENTIFIER    

wtWebGraphThermoBaroGraphicsScale 1.3.6.1.4.1.5040.1.2.37.3.1.6.3
OBJECT IDENTIFIER    

wtWebGraphThermoBaroSensors 1.3.6.1.4.1.5040.1.2.37.1.1
Number of sensors
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtWebGraphThermoBaroSensorTable 1.3.6.1.4.1.5040.1.2.37.1.2
List of sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebGraphThermoBaroSensorEntry

wtWebGraphThermoBaroSensorEntry 1.3.6.1.4.1.5040.1.2.37.1.2.1
List of sensor numbers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebGraphThermoBaroSensorEntry  

wtWebGraphThermoBaroSensorNo 1.3.6.1.4.1.5040.1.2.37.1.2.1.1
Sensor number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtWebGraphThermoBaroTempValueTable 1.3.6.1.4.1.5040.1.2.37.1.3
List of measurement values corresponding to the channel numbers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebGraphThermoBaroTempValueEntry

wtWebGraphThermoBaroTempValueEntry 1.3.6.1.4.1.5040.1.2.37.1.3.1
Measurement values of the sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebGraphThermoBaroTempValueEntry  

wtWebGraphThermoBaroTempValue 1.3.6.1.4.1.5040.1.2.37.1.3.1.1
Measurement value of the sensor, ASCII, 5 characters in length.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(5)  

wtWebGraphThermoBaroBinaryTempValueTable 1.3.6.1.4.1.5040.1.2.37.1.4
List of binary measurement values corresponding to the channel numbers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebGraphThermoBaroBinaryTempValueEntry

wtWebGraphThermoBaroBinaryTempValueEntry 1.3.6.1.4.1.5040.1.2.37.1.4.1
Binary measurement values of the sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebGraphThermoBaroBinaryTempValueEntry  

wtWebGraphThermoBaroBinaryTempValue 1.3.6.1.4.1.5040.1.2.37.1.4.1.1
Binary measurement value of the sensor in 1/10 degrees Celsius or 1/10 per cent, signed number, 0x4FFF6 indicates an invalid measured value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermoBaroTempValuePktTable 1.3.6.1.4.1.5040.1.2.37.1.8
List of measurement values corresponding to the channel numbers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebGraphThermoBaroTempValuePktEntry

wtWebGraphThermoBaroTempValuePktEntry 1.3.6.1.4.1.5040.1.2.37.1.8.1
Measurement values of the sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebGraphThermoBaroTempValuePktEntry  

wtWebGraphThermoBaroTempValuePkt 1.3.6.1.4.1.5040.1.2.37.1.8.1.1
Measurement value of the sensor, ASCII, 5 characters in length, delimeter is decimal point.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(5)  

wtWebGraphThermoBaroSessCntrlPassword 1.3.6.1.4.1.5040.1.2.37.2.1
Entering this password opens a session which is ended by writing a 1 to wtWebGraphThermoBaroSessCntrlLogout. When read this variable provides a string of length zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroSessCntrlConfigMode 1.3.6.1.4.1.5040.1.2.37.2.2
When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtWebGraphThermoBaroSessCntrl-NoSession(0), wtWebGraphThermoBaroSessCntrl-Session(1)  

wtWebGraphThermoBaroSessCntrlLogout 1.3.6.1.4.1.5040.1.2.37.2.3
If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermoBaroSessCntrlAdminPassword 1.3.6.1.4.1.5040.1.2.37.2.4
This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroSessCntrlConfigPassword 1.3.6.1.4.1.5040.1.2.37.2.5
This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroDeviceName 1.3.6.1.4.1.5040.1.2.37.3.1.1.1
Name of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroDeviceText 1.3.6.1.4.1.5040.1.2.37.3.1.1.2
Description of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroDeviceLocation 1.3.6.1.4.1.5040.1.2.37.3.1.1.3
Description of the location of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroDeviceContact 1.3.6.1.4.1.5040.1.2.37.3.1.1.4
Contact address of the system operator of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroTzOffsetHrs 1.3.6.1.4.1.5040.1.2.37.3.1.2.1.1
Offset hours for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermoBaroTzOffsetMin 1.3.6.1.4.1.5040.1.2.37.3.1.2.1.2
Offset minutes for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermoBaroTzEnable 1.3.6.1.4.1.5040.1.2.37.3.1.2.1.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphThermoBaroStTzOffsetHrs 1.3.6.1.4.1.5040.1.2.37.3.1.2.1.4
Offset hours of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermoBaroStTzOffsetMin 1.3.6.1.4.1.5040.1.2.37.3.1.2.1.5
Offset minutes of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermoBaroStTzEnable 1.3.6.1.4.1.5040.1.2.37.3.1.2.1.6
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphThermoBaroStTzStartMonth 1.3.6.1.4.1.5040.1.2.37.3.1.2.1.7
Month in which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebGraphThermoBaroStartMonth-January(1), wtWebGraphThermoBaroStartMonth-February(2), wtWebGraphThermoBaroStartMonth-March(3), wtWebGraphThermoBaroStartMonth-April(4), wtWebGraphThermoBaroStartMonth-May(5), wtWebGraphThermoBaroStartMonth-June(6), wtWebGraphThermoBaroStartMonth-July(7), wtWebGraphThermoBaroStartMonth-August(8), wtWebGraphThermoBaroStartMonth-September(9), wtWebGraphThermoBaroStartMonth-October(10), wtWebGraphThermoBaroStartMonth-November(11), wtWebGraphThermoBaroStartMonth-December(12)  

wtWebGraphThermoBaroStTzStartMode 1.3.6.1.4.1.5040.1.2.37.3.1.2.1.8
Mode of the day of the week for which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebGraphThermoBaroStartMode-first(1), wtWebGraphThermoBaroStartMode-second(2), wtWebGraphThermoBaroStartMode-third(3), wtWebGraphThermoBaroStartMode-fourth(4), wtWebGraphThermoBaroStartMode-last(5)  

wtWebGraphThermoBaroStTzStartWday 1.3.6.1.4.1.5040.1.2.37.3.1.2.1.9
Day of the week on which the change is made from winter time to summer time
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebGraphThermoBaroStartWday-Sunday(1), wtWebGraphThermoBaroStartWday-Monday(2), wtWebGraphThermoBaroStartWday-Tuesday(3), wtWebGraphThermoBaroStartWday-Thursday(4), wtWebGraphThermoBaroStartWday-Wednesday(5), wtWebGraphThermoBaroStartWday-Friday(6), wtWebGraphThermoBaroStartWday-Saturday(7)  

wtWebGraphThermoBaroStTzStartHrs 1.3.6.1.4.1.5040.1.2.37.3.1.2.1.10
Hour in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermoBaroStTzStartMin 1.3.6.1.4.1.5040.1.2.37.3.1.2.1.11
Minute in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermoBaroStTzStopMonth 1.3.6.1.4.1.5040.1.2.37.3.1.2.1.12
Month in which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebGraphThermoBaroStopMonth-January(1), wtWebGraphThermoBaroStopMonth-February(2), wtWebGraphThermoBaroStopMonth-March(3), wtWebGraphThermoBaroStopMonth-April(4), wtWebGraphThermoBaroStopMonth-May(5), wtWebGraphThermoBaroStopMonth-June(6), wtWebGraphThermoBaroStopMonth-July(7), wtWebGraphThermoBaroStopMonth-August(8), wtWebGraphThermoBaroStopMonth-September(9), wtWebGraphThermoBaroStopMonth-October(10), wtWebGraphThermoBaroStopMonth-November(11), wtWebGraphThermoBaroStopMonth-December(12)  

wtWebGraphThermoBaroStTzStopMode 1.3.6.1.4.1.5040.1.2.37.3.1.2.1.13
Mode of the week day on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebGraphThermoBaroStopMode-first(1), wtWebGraphThermoBaroStopMode-second(2), wtWebGraphThermoBaroStopMode-third(3), wtWebGraphThermoBaroStopMode-fourth(4), wtWebGraphThermoBaroStopMode-last(5)  

wtWebGraphThermoBaroStTzStopWday 1.3.6.1.4.1.5040.1.2.37.3.1.2.1.14
Day of the week on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebGraphThermoBaroStopWday-Sunday(1), wtWebGraphThermoBaroStopWday-Monday(2), wtWebGraphThermoBaroStopWday-Tuesday(3), wtWebGraphThermoBaroStopWday-Thursday(4), wtWebGraphThermoBaroStopWday-Wednesday(5), wtWebGraphThermoBaroStopWday-Friday(6), wtWebGraphThermoBaroStopWday-Saturday(7)  

wtWebGraphThermoBaroStTzStopHrs 1.3.6.1.4.1.5040.1.2.37.3.1.2.1.15
Hour at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermoBaroStTzStopMin 1.3.6.1.4.1.5040.1.2.37.3.1.2.1.16
Minute at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermoBaroTimeServer1 1.3.6.1.4.1.5040.1.2.37.3.1.2.2.1
IP address or name of the 1st time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroTimeServer2 1.3.6.1.4.1.5040.1.2.37.3.1.2.2.2
IP address or name of the 2nd time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroTsEnable 1.3.6.1.4.1.5040.1.2.37.3.1.2.2.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphThermoBaroTsSyncTime 1.3.6.1.4.1.5040.1.2.37.3.1.2.2.4
Daily synchronisation time with the time server (hour: 0-23).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermoBaroClockHrs 1.3.6.1.4.1.5040.1.2.37.3.1.2.3.1
Clock hours taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..23  

wtWebGraphThermoBaroClockMin 1.3.6.1.4.1.5040.1.2.37.3.1.2.3.2
Clock minutes taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..59  

wtWebGraphThermoBaroClockDay 1.3.6.1.4.1.5040.1.2.37.3.1.2.3.3
Date: Day of the month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..31  

wtWebGraphThermoBaroClockMonth 1.3.6.1.4.1.5040.1.2.37.3.1.2.3.4
Date: Month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebGraphThermoBaroClockMonth-January(1), wtWebGraphThermoBaroClockMonth-February(2), wtWebGraphThermoBaroClockMonth-March(3), wtWebGraphThermoBaroClockMonth-April(4), wtWebGraphThermoBaroClockMonth-May(5), wtWebGraphThermoBaroClockMonth-June(6), wtWebGraphThermoBaroClockMonth-July(7), wtWebGraphThermoBaroClockMonth-August(8), wtWebGraphThermoBaroClockMonth-September(9), wtWebGraphThermoBaroClockMonth-October(10), wtWebGraphThermoBaroClockMonth-November(11), wtWebGraphThermoBaroClockMonth-December(12)  

wtWebGraphThermoBaroClockYear 1.3.6.1.4.1.5040.1.2.37.3.1.2.3.5
Date: Year, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebGraphThermoBaroIpAddress 1.3.6.1.4.1.5040.1.2.37.3.1.3.1.1
IP address of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebGraphThermoBaroSubnetMask 1.3.6.1.4.1.5040.1.2.37.3.1.3.1.2
Subnet mask of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebGraphThermoBaroGateway 1.3.6.1.4.1.5040.1.2.37.3.1.3.1.3
Gateway of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebGraphThermoBaroDnsServer1 1.3.6.1.4.1.5040.1.2.37.3.1.3.1.4
IP address of the 1st DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroDnsServer2 1.3.6.1.4.1.5040.1.2.37.3.1.3.1.5
IP address of the 2nd DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroAddConfig 1.3.6.1.4.1.5040.1.2.37.3.1.3.1.6
Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP disable Bit 0: BOOTP disable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroStartup 1.3.6.1.4.1.5040.1.2.37.3.1.3.2.1
Binary coded start page: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: Index.htm Bit 2: Home.htm Bit 3: User.htm Only one page may be selected at a time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroGetHeaderEnable 1.3.6.1.4.1.5040.1.2.37.3.1.3.2.2
If these bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device and/or a HTTP header: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-6: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroHttpPort 1.3.6.1.4.1.5040.1.2.37.3.1.3.2.3
Definition of the standard HTML port (Default: 80).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebGraphThermoBaroMailAdName 1.3.6.1.4.1.5040.1.2.37.3.1.3.3.1
Device name for mail administration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroMailReply 1.3.6.1.4.1.5040.1.2.37.3.1.3.3.2
Reply address for the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroMailServer 1.3.6.1.4.1.5040.1.2.37.3.1.3.3.3
Name or IP address of the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1MailEnable 1.3.6.1.4.1.5040.1.2.37.3.1.3.3.4
Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroMailAuthentication 1.3.6.1.4.1.5040.1.2.37.3.1.3.3.5
Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphThermoBaroMailAuthUser 1.3.6.1.4.1.5040.1.2.37.3.1.3.3.6
Name of the user to be authenticated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroMailAuthPassword 1.3.6.1.4.1.5040.1.2.37.3.1.3.3.7
Authentication password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroMailPop3Server 1.3.6.1.4.1.5040.1.2.37.3.1.3.3.8
Name or Ip-address of the POP3 Servers.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroSnmpCommunityStringRead 1.3.6.1.4.1.5040.1.2.37.3.1.3.4.1
Community string read only
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroSnmpCommunityStringReadWrite 1.3.6.1.4.1.5040.1.2.37.3.1.3.4.2
Community string read / write
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroSystemTrapManagerIP 1.3.6.1.4.1.5040.1.2.37.3.1.3.4.3
Name or IP address of the TCP server which accepts the system trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroSystemTrapEnable 1.3.6.1.4.1.5040.1.2.37.3.1.3.4.4
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphThermoBaroSnmpEnable 1.3.6.1.4.1.5040.1.2.37.3.1.3.4.5
Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroSnmpCommunityStringTrap 1.3.6.1.4.1.5040.1.2.37.3.1.3.4.6
Community string send within traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroUdpPort 1.3.6.1.4.1.5040.1.2.37.3.1.3.5.1
Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebGraphThermoBaroUdpEnable 1.3.6.1.4.1.5040.1.2.37.3.1.3.5.2
Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroSyslogServerIP 1.3.6.1.4.1.5040.1.2.37.3.1.3.6.1
Name or IP address of the Syslog server, which accepts the Syslog messgaes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroSyslogServerPort 1.3.6.1.4.1.5040.1.2.37.3.1.3.6.2
Portnumber of the Syslog servers, default 514.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermoBaroSyslogSystemMessagesEnable 1.3.6.1.4.1.5040.1.2.37.3.1.3.6.3
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphThermoBaroSyslogEnable 1.3.6.1.4.1.5040.1.2.37.3.1.3.6.4
Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroFTPServerIP 1.3.6.1.4.1.5040.1.2.37.3.1.3.7.1
Name or IP address of the FTP server, which accepts the FTP messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroFTPServerControlPort 1.3.6.1.4.1.5040.1.2.37.3.1.3.7.2
Portnumber of the control port of the FTP server, default 21.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermoBaroFTPUserName 1.3.6.1.4.1.5040.1.2.37.3.1.3.7.3
FTP Loggin: user name.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroFTPPassword 1.3.6.1.4.1.5040.1.2.37.3.1.3.7.4
FTP Loggin: user password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroFTPAccount 1.3.6.1.4.1.5040.1.2.37.3.1.3.7.5
FTP Loggin: name of account.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroFTPOption 1.3.6.1.4.1.5040.1.2.37.3.1.3.7.6
Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroFTPEnable 1.3.6.1.4.1.5040.1.2.37.3.1.3.7.7
Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroLanguageSelect 1.3.6.1.4.1.5040.1.2.37.3.1.3.9.1
Sprachauswahl: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2-7: unused Bit 1 : englisch Bit 0 : german
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroLoggerTimebase 1.3.6.1.4.1.5040.1.2.37.3.1.4.1
Time base of the data logger
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebGraphThermoBaroDatalogger-1Min(1), wtWebGraphThermoBaroDatalogger-5Min(2), wtWebGraphThermoBaroDatalogger-15Min(3), wtWebGraphThermoBaroDatalogger-60Min(4)  

wtWebGraphThermoBaroLoggerSensorSel 1.3.6.1.4.1.5040.1.2.37.3.1.4.2
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphThermoBaroRSSChannelTitle 1.3.6.1.4.1.5040.1.2.37.3.1.3.8.1
Name of the RSS Feed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  


wtWebGraphThermoBaroRSSChannelDescription 1.3.6.1.4.1.5040.1.2.37.3.1.3.8.3
Description of the RSS Feed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroRSSChannelImage 1.3.6.1.4.1.5040.1.2.37.3.1.3.8.4
Link of a picture, which will be shown at the headline of the output window.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroRSSChannelImageTitle 1.3.6.1.4.1.5040.1.2.37.3.1.3.8.5
Alias Name of the picture.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  


wtWebGraphThermoBaroRSSChannelItemTitle 1.3.6.1.4.1.5040.1.2.37.3.1.3.8.7
Title of the RSS Feed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  


wtWebGraphThermoBaroRSSChannelItemDescription 1.3.6.1.4.1.5040.1.2.37.3.1.3.8.9
Text of the RSS Feed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroRSSChannelItemQuantity 1.3.6.1.4.1.5040.1.2.37.3.1.3.8.10
Number of lines.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroAlarmCount 1.3.6.1.4.1.5040.1.2.37.3.1.5.1
Number of independent alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..8  

wtWebGraphThermoBaroAlarmIfTable 1.3.6.1.4.1.5040.1.2.37.3.1.5.2
List of alarm indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebGraphThermoBaroAlarmIfEntry

wtWebGraphThermoBaroAlarmIfEntry 1.3.6.1.4.1.5040.1.2.37.3.1.5.2.1
Numbers of the alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebGraphThermoBaroAlarmIfEntry  

wtWebGraphThermoBaroAlarmNo 1.3.6.1.4.1.5040.1.2.37.3.1.5.2.1.1
Alarm number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..8  

wtWebGraphThermoBaroAlarmTable 1.3.6.1.4.1.5040.1.2.37.3.1.5.3
List of settings depending on the alarm number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebGraphThermoBaroAlarmEntry

wtWebGraphThermoBaroAlarmEntry 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1
Alarm parameters of the individual alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebGraphThermoBaroAlarmEntry  

wtWebGraphThermoBaroAlarmTrigger 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.1
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: Bit 0: Timer Bit 1: ColdStart Bit 2: WarmStart Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphThermoBaroAlarmMin 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.2
Minimum temperature in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroAlarmMax 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.3
Maximum temperature in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroAlarmHysteresis 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.4
Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.) , in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroAlarmDelay 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.5
Alarm will be delayed by setting this time while stable alarm condition occur (time in minutes).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroAlarmInterval 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.6
Send interval for alarm messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroAlarmEnable 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.7
Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable Bit 3: Syslog enable Bit 4: FTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphThermoBaroAlarmEMailAddr 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.8
E-Mail address for sending the alarm mail to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroAlarmMailSubject 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.9
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroAlarmMailText 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.10
Alarm mail text: provides the current temperature; n = 1..8. provides the current time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroAlarmManagerIP 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.11
Name or IP address of the SNMP Manager which accepts the trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroAlarmTrapText 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.12
This text is sent in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroAlarmMailOptions 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.13
Binary coded options: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphThermoBaroAlarmTcpIpAddr 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.14
Name or IP address of the TCP server which accepts the trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroAlarmTcpPort 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.15
Port number of the TCP server which accepts the trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebGraphThermoBaroAlarmTcpText 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.16
This text is sent in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroAlarmClearMailSubject 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.17
Subject line for alarm clear mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroAlarmClearMailText 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.18
Alarm clear mail text: provides the current temperature; n = 1..8. provides the current time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroAlarmClearTrapText 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.19
This text is sent in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroAlarmClearTcpText 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.20
This text is sent in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroAlarmDeltaTemp 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.21
Maximum rate of change degrees/min with maximum 2 decimal places. Compared with the average of a period of 5 minutes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroAlarmRHMin 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.22
Minimum rel. Humidity in percent with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroAlarmRHMax 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.23
Maximum rel.Humidity in percent with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroAlarmRHHysteresis 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.24
Hysterese rel. Humidity in percent with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroAlarmAHMin 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.25
Minimum abs. Humidity in g/(m*m*m) with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroAlarmAHMax 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.26
Maximum abs. Humidity in g/(m*m*m) with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroAlarmSyslogIpAddr 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.27
IP address of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebGraphThermoBaroAlarmSyslogPort 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.28
Port number of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebGraphThermoBaroAlarmSyslogText 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.29
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroAlarmSyslogClearText 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.30
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroAlarmFtpDataPort 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.31
Local data port: 1..65535 or AUTO: the next free port will be assigned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroAlarmFtpFileName 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.32
Name of the file including path informations.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroAlarmFtpText 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.33
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroAlarmFtpClearText 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.34
Alarm clear message to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroAlarmFtpOption 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.35
Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphThermoBaroAlarmTimerCron 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.36
This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroAlarmName 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.39
Alert name
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroAlarmActive 1.3.6.1.4.1.5040.1.2.37.3.1.5.3.1.40
Alert active 1 = ON 0 = OFF
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroGraphicsBaseEnable 1.3.6.1.4.1.5040.1.2.37.3.1.6.1.1
Defines the viewing options of the graphic: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Auto scroll enable Bit 1 : Show table Bit 2 : Show graph Bit 3 : Show control buttons Bit 4 : Show config menu Bit 5-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroGraphicsBaseWidth 1.3.6.1.4.1.5040.1.2.37.3.1.6.1.2
Defines the width of the graphic in pixels.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermoBaroGraphicsBaseHeight 1.3.6.1.4.1.5040.1.2.37.3.1.6.1.3
Defines the height of the graphic in pixels.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermoBaroGraphicsBaseFrameColor 1.3.6.1.4.1.5040.1.2.37.3.1.6.1.4
Frame color definition in RGB.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(3)  

wtWebGraphThermoBaroGraphicsBaseBackgroundColor 1.3.6.1.4.1.5040.1.2.37.3.1.6.1.5
Background color definition in RGB.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(3)  

wtWebGraphThermoBaroGraphicsBasePollingrate 1.3.6.1.4.1.5040.1.2.37.3.1.6.1.6
Defines the pollingrate in seconds, which defines the refreshing intervall of the graphic.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermoBaroGraphicsSelectDisplaySensorSel 1.3.6.1.4.1.5040.1.2.37.3.1.6.2.1
Binary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphThermoBaroGraphicsSelectDisplayShowExtrem 1.3.6.1.4.1.5040.1.2.37.3.1.6.2.2
Binary coded sensor selection: only selected sensors will be shown with minima and maxima: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphThermoBaroSensorColorTable 1.3.6.1.4.1.5040.1.2.37.3.1.6.2.3
List of sensor colors for the praphical presentation.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebGraphThermoBaroSensorColorEntry

wtWebGraphThermoBaroSensorColorEntry 1.3.6.1.4.1.5040.1.2.37.3.1.6.2.3.1
Numbers of the sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebGraphThermoBaroSensorColorEntry  

wtWebGraphThermoBaroGraphicsSensorColor 1.3.6.1.4.1.5040.1.2.37.3.1.6.2.3.1.1
Color of the sensors at the praphical presention.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(3)  

wtWebGraphThermoBaroGraphicsSelectScale 1.3.6.1.4.1.5040.1.2.37.3.1.6.2.3.1.2
Assignes one of 4 scales to a sensor: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Use Scale 1 Bit 1 : Use Scale 2 Bit 2 : Use Scale 3 Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroGraphicsScaleAutoScaleEnable 1.3.6.1.4.1.5040.1.2.37.3.1.6.3.1
Select the Auto Scale Mode: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto scale enable Bit 1 : Scale 2 Auto scale enable Bit 2 : Scale 3 Auto scale enable Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroGraphicsScaleAutoFitEnable 1.3.6.1.4.1.5040.1.2.37.3.1.6.3.2
Select the Auto Fit Mode:: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto fit enable Bit 1 : Scale 2 Auto fit enable Bit 2 : Scale 3 Auto fit enable Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroGraphicsScale1Min 1.3.6.1.4.1.5040.1.2.37.3.1.6.3.3
Scale 1: Minimum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermoBaroGraphicsScale2Min 1.3.6.1.4.1.5040.1.2.37.3.1.6.3.4
Scale 2: Minimum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermoBaroGraphicsScale3Min 1.3.6.1.4.1.5040.1.2.37.3.1.6.3.5
Scale 3: Minimum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermoBaroGraphicsScale4Min 1.3.6.1.4.1.5040.1.2.37.3.1.6.3.6
Scale 4: Minimum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermoBaroGraphicsScale1Max 1.3.6.1.4.1.5040.1.2.37.3.1.6.3.7
Scale 1: Maximum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermoBaroGraphicsScale2Max 1.3.6.1.4.1.5040.1.2.37.3.1.6.3.8
Scale 2: Maximum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermoBaroGraphicsScale3Max 1.3.6.1.4.1.5040.1.2.37.3.1.6.3.9
Scale 3: Maximum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermoBaroGraphicsScale4Max 1.3.6.1.4.1.5040.1.2.37.3.1.6.3.10
Scale 4: Maximum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermoBaroGraphicsScale1Unit 1.3.6.1.4.1.5040.1.2.37.3.1.6.3.11
Scale 1: Unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroGraphicsScale2Unit 1.3.6.1.4.1.5040.1.2.37.3.1.6.3.12
Scale 2: Unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroGraphicsScale3Unit 1.3.6.1.4.1.5040.1.2.37.3.1.6.3.13
Scale 3: Unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroGraphicsScale4Unit 1.3.6.1.4.1.5040.1.2.37.3.1.6.3.14
Scale 4: Unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroPortTable 1.3.6.1.4.1.5040.1.2.37.3.2.1
List of settings depending on the sensor number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebGraphThermoBaroPortEntry

wtWebGraphThermoBaroPortEntry 1.3.6.1.4.1.5040.1.2.37.3.2.1.1
Sensor parameters for the individual sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebGraphThermoBaroPortEntry  

wtWebGraphThermoBaroPortName 1.3.6.1.4.1.5040.1.2.37.3.2.1.1.1
Name of the sensor.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroPortText 1.3.6.1.4.1.5040.1.2.37.3.2.1.1.2
Description of the sensor.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroPortOffset1 1.3.6.1.4.1.5040.1.2.37.3.2.1.1.3
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroPortTemperature1 1.3.6.1.4.1.5040.1.2.37.3.2.1.1.4
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroPortOffset2 1.3.6.1.4.1.5040.1.2.37.3.2.1.1.5
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroPortTemperature2 1.3.6.1.4.1.5040.1.2.37.3.2.1.1.6
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroPortComment 1.3.6.1.4.1.5040.1.2.37.3.2.1.1.7
Offset calibration: informations of date, name of operator, reference devices.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroPortAltidude 1.3.6.1.4.1.5040.1.2.37.3.2.2
Altidude oh the Sensor over mean sea level (MSL).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroMfName 1.3.6.1.4.1.5040.1.2.37.3.3.1
Manufacturer company name
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroMfAddr 1.3.6.1.4.1.5040.1.2.37.3.3.2
Manufacturer address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroMfHotline 1.3.6.1.4.1.5040.1.2.37.3.3.3
Manufacturer hotline.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroMfInternet 1.3.6.1.4.1.5040.1.2.37.3.3.4
Manufacturer Internet address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroMfDeviceTyp 1.3.6.1.4.1.5040.1.2.37.3.3.5
Manufacturer device name (model number).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroMfOrderNo 1.3.6.1.4.1.5040.1.2.37.3.3.6
Manufacturer part number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroDiagErrorCount 1.3.6.1.4.1.5040.1.2.37.4.1
Number of entries in the error memory.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermoBaroDiagBinaryError 1.3.6.1.4.1.5040.1.2.37.4.2
Error causes coded bit-by-bit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroDiagErrorIndex 1.3.6.1.4.1.5040.1.2.37.4.3
The value of this variable is used as an index to read an error massege from wtWebGraphThermoBaroDiagErrorMessage. Errors are numbered from 1 to wtWebGraphThermoBaroDiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebGraphThermoBaroDiagErrorMessage.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermoBaroDiagErrorMessage 1.3.6.1.4.1.5040.1.2.37.4.4
Using wtWebGraphThermoBaroDiagErrorIndex as an index, the appropriate message is available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphThermoBaroDiagErrorClear 1.3.6.1.4.1.5040.1.2.37.4.5
Writing 1 into this variable clears all diagnosis messages.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER  

wtWebGraphThermoBaroAlert1 31
This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphThermoBaroAlert2 32
This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphThermoBaroAlert3 33
This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphThermoBaroAlert4 34
This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphThermoBaroAlert5 35
This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphThermoBaroAlert6 36
This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphThermoBaroAlert7 37
This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphThermoBaroAlert8 38
This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphThermoBaroAlert9 91
This SNMP trap is generated when Alarm 1 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphThermoBaroAlert10 92
This SNMP trap is generated when Alarm 2 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphThermoBaroAlert11 93
This SNMP trap is generated when Alarm 3 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphThermoBaroAlert12 94
This SNMP trap is generated when Alarm 4 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphThermoBaroAlert13 95
This SNMP trap is generated when Alarm 5 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphThermoBaroAlert14 96
This SNMP trap is generated when Alarm 6 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphThermoBaroAlert15 97
This SNMP trap is generated when Alarm 7 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphThermoBaroAlert16 98
This SNMP trap is generated when Alarm 8 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphThermoBaroAlertDiag 110
This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE