WebGraph-Air-Quality-US-MIB

File: WebGraph-Air-Quality-US-MIB.mib (77610 bytes)

Imported modules

RFC-1212 RFC-1215 RFC1213-MIB
RFC1155-SMI

Imported symbols

OBJECT-TYPE TRAP-TYPE DisplayString
PhysAddress enterprises TimeTicks
IpAddress NetworkAddress

Defined Types

WtWebGraphAirQualitySensorEntry  
SEQUENCE    
  wtWebGraphAirQualitySensorNo INTEGER

WtWebGraphAirQualityTempValueEntry  
SEQUENCE    
  wtWebGraphAirQualityTempValue OCTET STRING

WtWebGraphAirQualityBinaryTempValueEntry  
SEQUENCE    
  wtWebGraphAirQualityBinaryTempValue INTEGER

WtWebGraphAirQualityTempValuePktEntry  
SEQUENCE    
  wtWebGraphAirQualityTempValuePkt OCTET STRING

WtWebGraphAirQualityAlarmIfEntry  
SEQUENCE    
  wtWebGraphAirQualityAlarmNo INTEGER

WtWebGraphAirQualityAlarmEntry  
SEQUENCE    
  wtWebGraphAirQualityAlarmTrigger OCTET STRING
  wtWebGraphAirQualityAlarmMin OCTET STRING
  wtWebGraphAirQualityAlarmMax OCTET STRING
  wtWebGraphAirQualityAlarmHysteresis OCTET STRING
  wtWebGraphAirQualityAlarmDelay OCTET STRING
  wtWebGraphAirQualityAlarmInterval OCTET STRING
  wtWebGraphAirQualityAlarmEnable OCTET STRING
  wtWebGraphAirQualityAlarmEMailAddr OCTET STRING
  wtWebGraphAirQualityAlarmMailSubject OCTET STRING
  wtWebGraphAirQualityAlarmMailText OCTET STRING
  wtWebGraphAirQualityAlarmManagerIP OCTET STRING
  wtWebGraphAirQualityAlarmTrapText OCTET STRING
  wtWebGraphAirQualityAlarmMailOptions OCTET STRING
  wtWebGraphAirQualityAlarmTcpIpAddr OCTET STRING
  wtWebGraphAirQualityAlarmTcpPort INTEGER
  wtWebGraphAirQualityAlarmTcpText OCTET STRING
  wtWebGraphAirQualityAlarmClearMailSubject OCTET STRING
  wtWebGraphAirQualityAlarmClearMailText OCTET STRING
  wtWebGraphAirQualityAlarmClearTrapText OCTET STRING
  wtWebGraphAirQualityAlarmClearTcpText OCTET STRING
  wtWebGraphAirQualityAlarmDeltaTemp OCTET STRING
  wtWebGraphAirQualityAlarmRHMin OCTET STRING
  wtWebGraphAirQualityAlarmRHMax OCTET STRING
  wtWebGraphAirQualityAlarmRHHysteresis OCTET STRING
  wtWebGraphAirQualityAlarmAHMin OCTET STRING
  wtWebGraphAirQualityAlarmAHMax OCTET STRING
  wtWebGraphAirQualityAlarmSyslogIpAddr OCTET STRING
  wtWebGraphAirQualityAlarmSyslogPort INTEGER
  wtWebGraphAirQualityAlarmSyslogText OCTET STRING
  wtWebGraphAirQualityAlarmSyslogClearText OCTET STRING
  wtWebGraphAirQualityAlarmFtpDataPort OCTET STRING
  wtWebGraphAirQualityAlarmFtpFileName OCTET STRING
  wtWebGraphAirQualityAlarmFtpText OCTET STRING
  wtWebGraphAirQualityAlarmFtpClearText OCTET STRING
  wtWebGraphAirQualityAlarmFtpOption OCTET STRING
  wtWebGraphAirQualityAlarmTimerCron OCTET STRING
  wtWebGraphAirQualityAlarmVocMax OCTET STRING
  wtWebGraphAirQualityAlarmVocHysteresis OCTET STRING
  wtWebGraphAirQualityAlarmName OCTET STRING
  wtWebGraphAirQualityAlarmActive OCTET STRING

WtWebGraphAirQualitySensorColorEntry  
SEQUENCE    
  wtWebGraphAirQualityGraphicsSensorColor OCTET STRING
  wtWebGraphAirQualityGraphicsSelectScale OCTET STRING

WtWebGraphAirQualityPortEntry  
SEQUENCE    
  wtWebGraphAirQualityPortName OCTET STRING
  wtWebGraphAirQualityPortText OCTET STRING
  wtWebGraphAirQualityPortOffset1 OCTET STRING
  wtWebGraphAirQualityPortTemperature1 OCTET STRING
  wtWebGraphAirQualityPortOffset2 OCTET STRING
  wtWebGraphAirQualityPortTemperature2 OCTET STRING
  wtWebGraphAirQualityPortComment OCTET STRING

Defined Values

wut 1.3.6.1.4.1.5040
OBJECT IDENTIFIER    

wtComServer 1.3.6.1.4.1.5040.1
OBJECT IDENTIFIER    

wtWebio 1.3.6.1.4.1.5040.1.2
OBJECT IDENTIFIER    

wtWebGraphAirQuality 1.3.6.1.4.1.5040.1.2.35
OBJECT IDENTIFIER    

wtWebGraphAirQualityTemp 1.3.6.1.4.1.5040.1.2.35.1
OBJECT IDENTIFIER    

wtWebGraphAirQualitySessCntrl 1.3.6.1.4.1.5040.1.2.35.2
OBJECT IDENTIFIER    

wtWebGraphAirQualityConfig 1.3.6.1.4.1.5040.1.2.35.3
OBJECT IDENTIFIER    

wtWebGraphAirQualityDiag 1.3.6.1.4.1.5040.1.2.35.4
OBJECT IDENTIFIER    

wtWebGraphAirQualityDevice 1.3.6.1.4.1.5040.1.2.35.3.1
OBJECT IDENTIFIER    

wtWebGraphAirQualityPorts 1.3.6.1.4.1.5040.1.2.35.3.2
OBJECT IDENTIFIER    

wtWebGraphAirQualityManufact 1.3.6.1.4.1.5040.1.2.35.3.3
OBJECT IDENTIFIER    

wtWebGraphAirQualityText 1.3.6.1.4.1.5040.1.2.35.3.1.1
OBJECT IDENTIFIER    

wtWebGraphAirQualityTimeDate 1.3.6.1.4.1.5040.1.2.35.3.1.2
OBJECT IDENTIFIER    

wtWebGraphAirQualityBasic 1.3.6.1.4.1.5040.1.2.35.3.1.3
OBJECT IDENTIFIER    

wtWebGraphAirQualityDatalogger 1.3.6.1.4.1.5040.1.2.35.3.1.4
OBJECT IDENTIFIER    

wtWebGraphAirQualityAlarm 1.3.6.1.4.1.5040.1.2.35.3.1.5
OBJECT IDENTIFIER    

wtWebGraphAirQualityGraphics 1.3.6.1.4.1.5040.1.2.35.3.1.6
OBJECT IDENTIFIER    

wtWebGraphAirQualityTimeZone 1.3.6.1.4.1.5040.1.2.35.3.1.2.1
OBJECT IDENTIFIER    

wtWebGraphAirQualityTimeServer 1.3.6.1.4.1.5040.1.2.35.3.1.2.2
OBJECT IDENTIFIER    

wtWebGraphAirQualityDeviceClock 1.3.6.1.4.1.5040.1.2.35.3.1.2.3
OBJECT IDENTIFIER    

wtWebGraphAirQualityNetwork 1.3.6.1.4.1.5040.1.2.35.3.1.3.1
OBJECT IDENTIFIER    

wtWebGraphAirQualityHTTP 1.3.6.1.4.1.5040.1.2.35.3.1.3.2
OBJECT IDENTIFIER    

wtWebGraphAirQualityMail 1.3.6.1.4.1.5040.1.2.35.3.1.3.3
OBJECT IDENTIFIER    

wtWebGraphAirQualitySNMP 1.3.6.1.4.1.5040.1.2.35.3.1.3.4
OBJECT IDENTIFIER    

wtWebGraphAirQualityUDP 1.3.6.1.4.1.5040.1.2.35.3.1.3.5
OBJECT IDENTIFIER    

wtWebGraphAirQualitySyslog 1.3.6.1.4.1.5040.1.2.35.3.1.3.6
OBJECT IDENTIFIER    

wtWebGraphAirQualityFTP 1.3.6.1.4.1.5040.1.2.35.3.1.3.7
OBJECT IDENTIFIER    

wtWebGraphAirQualityRSS 1.3.6.1.4.1.5040.1.2.35.3.1.3.8
OBJECT IDENTIFIER    

wtWebGraphAirQualityLedLights 1.3.6.1.4.1.5040.1.2.35.3.1.3.9
OBJECT IDENTIFIER    

wtWebGraphAirQualityGraphicsBase 1.3.6.1.4.1.5040.1.2.35.3.1.6.1
OBJECT IDENTIFIER    

wtWebGraphAirQualityGraphicsSelect 1.3.6.1.4.1.5040.1.2.35.3.1.6.2
OBJECT IDENTIFIER    

wtWebGraphAirQualityGraphicsScale 1.3.6.1.4.1.5040.1.2.35.3.1.6.3
OBJECT IDENTIFIER    

wtWebGraphAirQualitySensors 1.3.6.1.4.1.5040.1.2.35.1.1
Number of sensors
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..3  

wtWebGraphAirQualitySensorTable 1.3.6.1.4.1.5040.1.2.35.1.2
List of sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebGraphAirQualitySensorEntry

wtWebGraphAirQualitySensorEntry 1.3.6.1.4.1.5040.1.2.35.1.2.1
List of sensor numbers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebGraphAirQualitySensorEntry  

wtWebGraphAirQualitySensorNo 1.3.6.1.4.1.5040.1.2.35.1.2.1.1
Sensor number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

wtWebGraphAirQualityTempValueTable 1.3.6.1.4.1.5040.1.2.35.1.3
List of measurement values corresponding to the channel numbers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebGraphAirQualityTempValueEntry

wtWebGraphAirQualityTempValueEntry 1.3.6.1.4.1.5040.1.2.35.1.3.1
Measurement values of the sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebGraphAirQualityTempValueEntry  

wtWebGraphAirQualityTempValue 1.3.6.1.4.1.5040.1.2.35.1.3.1.1
Measurement value of the sensor, ASCII, 5 characters in length.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(5)  

wtWebGraphAirQualityBinaryTempValueTable 1.3.6.1.4.1.5040.1.2.35.1.4
List of binary measurement values corresponding to the channel numbers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebGraphAirQualityBinaryTempValueEntry

wtWebGraphAirQualityBinaryTempValueEntry 1.3.6.1.4.1.5040.1.2.35.1.4.1
Binary measurement values of the sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebGraphAirQualityBinaryTempValueEntry  

wtWebGraphAirQualityBinaryTempValue 1.3.6.1.4.1.5040.1.2.35.1.4.1.1
Binary measurement value of the sensor in 1/10 degrees Celsius, 1/10 per cent or 1/10 ppm, signed number, 0x7FFFFFFF indicates an invalid measured value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebGraphAirQualityTempValuePktTable 1.3.6.1.4.1.5040.1.2.35.1.8
List of measurement values corresponding to the channel numbers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebGraphAirQualityTempValuePktEntry

wtWebGraphAirQualityTempValuePktEntry 1.3.6.1.4.1.5040.1.2.35.1.8.1
Measurement values of the sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebGraphAirQualityTempValuePktEntry  

wtWebGraphAirQualityTempValuePkt 1.3.6.1.4.1.5040.1.2.35.1.8.1.1
Measurement value of the sensor, ASCII, 5 characters in length, delimeter is decimal point.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(5)  

wtWebGraphAirQualitySessCntrlPassword 1.3.6.1.4.1.5040.1.2.35.2.1
Entering this password opens a session which is ended by writing a 1 to wtWebGraphAirQualitySessCntrlLogout. When read this variable provides a string of length zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualitySessCntrlConfigMode 1.3.6.1.4.1.5040.1.2.35.2.2
When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wtWebGraphAirQualitySessCntrl-NoSession(0), wtWebGraphAirQualitySessCntrl-Session(1)  

wtWebGraphAirQualitySessCntrlLogout 1.3.6.1.4.1.5040.1.2.35.2.3
If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphAirQualitySessCntrlAdminPassword 1.3.6.1.4.1.5040.1.2.35.2.4
This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualitySessCntrlConfigPassword 1.3.6.1.4.1.5040.1.2.35.2.5
This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityDeviceName 1.3.6.1.4.1.5040.1.2.35.3.1.1.1
Name of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityDeviceText 1.3.6.1.4.1.5040.1.2.35.3.1.1.2
Description of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityDeviceLocation 1.3.6.1.4.1.5040.1.2.35.3.1.1.3
Description of the location of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityDeviceContact 1.3.6.1.4.1.5040.1.2.35.3.1.1.4
Contact address of the system operator of the Webio, which is user definable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityTzOffsetHrs 1.3.6.1.4.1.5040.1.2.35.3.1.2.1.1
Offset hours for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphAirQualityTzOffsetMin 1.3.6.1.4.1.5040.1.2.35.3.1.2.1.2
Offset minutes for the time zone (winter time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphAirQualityTzEnable 1.3.6.1.4.1.5040.1.2.35.3.1.2.1.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphAirQualityStTzOffsetHrs 1.3.6.1.4.1.5040.1.2.35.3.1.2.1.4
Offset hours of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphAirQualityStTzOffsetMin 1.3.6.1.4.1.5040.1.2.35.3.1.2.1.5
Offset minutes of the time zone (summer time) with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphAirQualityStTzEnable 1.3.6.1.4.1.5040.1.2.35.3.1.2.1.6
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphAirQualityStTzStartMonth 1.3.6.1.4.1.5040.1.2.35.3.1.2.1.7
Month in which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebGraphAirQualityStartMonth-January(1), wtWebGraphAirQualityStartMonth-February(2), wtWebGraphAirQualityStartMonth-March(3), wtWebGraphAirQualityStartMonth-April(4), wtWebGraphAirQualityStartMonth-May(5), wtWebGraphAirQualityStartMonth-June(6), wtWebGraphAirQualityStartMonth-July(7), wtWebGraphAirQualityStartMonth-August(8), wtWebGraphAirQualityStartMonth-September(9), wtWebGraphAirQualityStartMonth-October(10), wtWebGraphAirQualityStartMonth-November(11), wtWebGraphAirQualityStartMonth-December(12)  

wtWebGraphAirQualityStTzStartMode 1.3.6.1.4.1.5040.1.2.35.3.1.2.1.8
Mode of the day of the week for which the change is made from winter time to summer time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebGraphAirQualityStartMode-first(1), wtWebGraphAirQualityStartMode-second(2), wtWebGraphAirQualityStartMode-third(3), wtWebGraphAirQualityStartMode-fourth(4), wtWebGraphAirQualityStartMode-last(5)  

wtWebGraphAirQualityStTzStartWday 1.3.6.1.4.1.5040.1.2.35.3.1.2.1.9
Day of the week on which the change is made from winter time to summer time
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebGraphAirQualityStartWday-Sunday(1), wtWebGraphAirQualityStartWday-Monday(2), wtWebGraphAirQualityStartWday-Tuesday(3), wtWebGraphAirQualityStartWday-Thursday(4), wtWebGraphAirQualityStartWday-Wednesday(5), wtWebGraphAirQualityStartWday-Friday(6), wtWebGraphAirQualityStartWday-Saturday(7)  

wtWebGraphAirQualityStTzStartHrs 1.3.6.1.4.1.5040.1.2.35.3.1.2.1.10
Hour in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphAirQualityStTzStartMin 1.3.6.1.4.1.5040.1.2.35.3.1.2.1.11
Minute in which the time zone is changed from winter to summer time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphAirQualityStTzStopMonth 1.3.6.1.4.1.5040.1.2.35.3.1.2.1.12
Month in which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebGraphAirQualityStopMonth-January(1), wtWebGraphAirQualityStopMonth-February(2), wtWebGraphAirQualityStopMonth-March(3), wtWebGraphAirQualityStopMonth-April(4), wtWebGraphAirQualityStopMonth-May(5), wtWebGraphAirQualityStopMonth-June(6), wtWebGraphAirQualityStopMonth-July(7), wtWebGraphAirQualityStopMonth-August(8), wtWebGraphAirQualityStopMonth-September(9), wtWebGraphAirQualityStopMonth-October(10), wtWebGraphAirQualityStopMonth-November(11), wtWebGraphAirQualityStopMonth-December(12)  

wtWebGraphAirQualityStTzStopMode 1.3.6.1.4.1.5040.1.2.35.3.1.2.1.13
Mode of the week day on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebGraphAirQualityStopMode-first(1), wtWebGraphAirQualityStopMode-second(2), wtWebGraphAirQualityStopMode-third(3), wtWebGraphAirQualityStopMode-fourth(4), wtWebGraphAirQualityStopMode-last(5)  

wtWebGraphAirQualityStTzStopWday 1.3.6.1.4.1.5040.1.2.35.3.1.2.1.14
Day of the week on which the change is made from summer time to winter time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebGraphAirQualityStopWday-Sunday(1), wtWebGraphAirQualityStopWday-Monday(2), wtWebGraphAirQualityStopWday-Tuesday(3), wtWebGraphAirQualityStopWday-Thursday(4), wtWebGraphAirQualityStopWday-Wednesday(5), wtWebGraphAirQualityStopWday-Friday(6), wtWebGraphAirQualityStopWday-Saturday(7)  

wtWebGraphAirQualityStTzStopHrs 1.3.6.1.4.1.5040.1.2.35.3.1.2.1.15
Hour at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphAirQualityStTzStopMin 1.3.6.1.4.1.5040.1.2.35.3.1.2.1.16
Minute at which the time zone is changed from summer to winter time with respect to UTC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphAirQualityTimeServer1 1.3.6.1.4.1.5040.1.2.35.3.1.2.2.1
IP address or name of the 1st time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityTimeServer2 1.3.6.1.4.1.5040.1.2.35.3.1.2.2.2
IP address or name of the 2nd time server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityTsEnable 1.3.6.1.4.1.5040.1.2.35.3.1.2.2.3
Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphAirQualityTsSyncTime 1.3.6.1.4.1.5040.1.2.35.3.1.2.2.4
Daily synchronisation time with the time server (hour: 0-23).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphAirQualityClockHrs 1.3.6.1.4.1.5040.1.2.35.3.1.2.3.1
Clock hours taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..23  

wtWebGraphAirQualityClockMin 1.3.6.1.4.1.5040.1.2.35.3.1.2.3.2
Clock minutes taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..59  

wtWebGraphAirQualityClockDay 1.3.6.1.4.1.5040.1.2.35.3.1.2.3.3
Date: Day of the month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..31  

wtWebGraphAirQualityClockMonth 1.3.6.1.4.1.5040.1.2.35.3.1.2.3.4
Date: Month, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebGraphAirQualityClockMonth-January(1), wtWebGraphAirQualityClockMonth-February(2), wtWebGraphAirQualityClockMonth-March(3), wtWebGraphAirQualityClockMonth-April(4), wtWebGraphAirQualityClockMonth-May(5), wtWebGraphAirQualityClockMonth-June(6), wtWebGraphAirQualityClockMonth-July(7), wtWebGraphAirQualityClockMonth-August(8), wtWebGraphAirQualityClockMonth-September(9), wtWebGraphAirQualityClockMonth-October(10), wtWebGraphAirQualityClockMonth-November(11), wtWebGraphAirQualityClockMonth-December(12)  

wtWebGraphAirQualityClockYear 1.3.6.1.4.1.5040.1.2.35.3.1.2.3.5
Date: Year, taking into account the time zone settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

wtWebGraphAirQualityIpAddress 1.3.6.1.4.1.5040.1.2.35.3.1.3.1.1
IP address of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebGraphAirQualitySubnetMask 1.3.6.1.4.1.5040.1.2.35.3.1.3.1.2
Subnet mask of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebGraphAirQualityGateway 1.3.6.1.4.1.5040.1.2.35.3.1.3.1.3
Gateway of the Webio
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebGraphAirQualityDnsServer1 1.3.6.1.4.1.5040.1.2.35.3.1.3.1.4
IP address of the 1st DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityDnsServer2 1.3.6.1.4.1.5040.1.2.35.3.1.3.1.5
IP address of the 2nd DNS server in ASCII
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityAddConfig 1.3.6.1.4.1.5040.1.2.35.3.1.3.1.6
Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP disable Bit 0: BOOTP disable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityStartup 1.3.6.1.4.1.5040.1.2.35.3.1.3.2.1
Binary coded start page: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 3: smart.htm Bit 2: user.htm Bit 1: home.htm Bit 0: index.htm Only one page may be selected at a time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityGetHeaderEnable 1.3.6.1.4.1.5040.1.2.35.3.1.3.2.2
If these bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device and/or a HTTP header: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-6: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityHttpPort 1.3.6.1.4.1.5040.1.2.35.3.1.3.2.3
Definition of the standard HTML port (Default: 80).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebGraphAirQualityMailAdName 1.3.6.1.4.1.5040.1.2.35.3.1.3.3.1
Device name for mail administration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityMailReply 1.3.6.1.4.1.5040.1.2.35.3.1.3.3.2
Reply address for the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityMailServer 1.3.6.1.4.1.5040.1.2.35.3.1.3.3.3
Name or IP address of the mail server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebioAn1MailEnable 1.3.6.1.4.1.5040.1.2.35.3.1.3.3.4
Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityMailAuthentication 1.3.6.1.4.1.5040.1.2.35.3.1.3.3.5
Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphAirQualityMailAuthUser 1.3.6.1.4.1.5040.1.2.35.3.1.3.3.6
Name of the user to be authenticated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityMailAuthPassword 1.3.6.1.4.1.5040.1.2.35.3.1.3.3.7
Authentication password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityMailPop3Server 1.3.6.1.4.1.5040.1.2.35.3.1.3.3.8
Name or Ip-address of the POP3 Servers.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualitySnmpCommunityStringRead 1.3.6.1.4.1.5040.1.2.35.3.1.3.4.1
Community string read only
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualitySnmpCommunityStringReadWrite 1.3.6.1.4.1.5040.1.2.35.3.1.3.4.2
Community string read / write
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualitySystemTrapManagerIP 1.3.6.1.4.1.5040.1.2.35.3.1.3.4.3
Name or IP address of the TCP server which accepts the system trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualitySystemTrapEnable 1.3.6.1.4.1.5040.1.2.35.3.1.3.4.4
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphAirQualitySnmpEnable 1.3.6.1.4.1.5040.1.2.35.3.1.3.4.5
Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualitySnmpCommunityStringTrap 1.3.6.1.4.1.5040.1.2.35.3.1.3.4.6
Community string send within traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityUdpPort 1.3.6.1.4.1.5040.1.2.35.3.1.3.5.1
Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebGraphAirQualityUdpEnable 1.3.6.1.4.1.5040.1.2.35.3.1.3.5.2
Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualitySyslogServerIP 1.3.6.1.4.1.5040.1.2.35.3.1.3.6.1
Name or IP address of the Syslog server, which accepts the Syslog messgaes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualitySyslogServerPort 1.3.6.1.4.1.5040.1.2.35.3.1.3.6.2
Portnumber of the Syslog servers, default 514.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphAirQualitySyslogSystemMessagesEnable 1.3.6.1.4.1.5040.1.2.35.3.1.3.6.3
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphAirQualitySyslogEnable 1.3.6.1.4.1.5040.1.2.35.3.1.3.6.4
Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityFTPServerIP 1.3.6.1.4.1.5040.1.2.35.3.1.3.7.1
Name or IP address of the FTP server, which accepts the FTP messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityFTPServerControlPort 1.3.6.1.4.1.5040.1.2.35.3.1.3.7.2
Portnumber of the control port of the FTP server, default 21.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphAirQualityFTPUserName 1.3.6.1.4.1.5040.1.2.35.3.1.3.7.3
FTP Loggin: user name.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityFTPPassword 1.3.6.1.4.1.5040.1.2.35.3.1.3.7.4
FTP Loggin: user password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityFTPAccount 1.3.6.1.4.1.5040.1.2.35.3.1.3.7.5
FTP Loggin: name of account.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityFTPOption 1.3.6.1.4.1.5040.1.2.35.3.1.3.7.6
Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityFTPEnable 1.3.6.1.4.1.5040.1.2.35.3.1.3.7.7
Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityRSSChannelTitle 1.3.6.1.4.1.5040.1.2.35.3.1.3.8.1
Name of the RSS Feed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  


wtWebGraphAirQualityRSSChannelDescription 1.3.6.1.4.1.5040.1.2.35.3.1.3.8.3
Description of the RSS Feed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityRSSChannelImage 1.3.6.1.4.1.5040.1.2.35.3.1.3.8.4
Link of a picture, which will be shown at the headline of the output window.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityRSSChannelImageTitle 1.3.6.1.4.1.5040.1.2.35.3.1.3.8.5
Alias Name of the picture.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  


wtWebGraphAirQualityRSSChannelItemTitle 1.3.6.1.4.1.5040.1.2.35.3.1.3.8.7
Title of the RSS Feed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  


wtWebGraphAirQualityRSSChannelItemDescription 1.3.6.1.4.1.5040.1.2.35.3.1.3.8.9
Text of the RSS Feed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityRSSChannelItemQuantity 1.3.6.1.4.1.5040.1.2.35.3.1.3.8.10
Number of lines.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityLedLightsSensorSel 1.3.6.1.4.1.5040.1.2.35.3.1.3.9.1
Binary coded trigger conditions, only one sensor may be selected at a time: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Sensor 1 Temperature Bit 1 : Sensor 2 Humidity Bit 2 : Sensor 3 VOC Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphAirQualityLedLightsLimitGreen 1.3.6.1.4.1.5040.1.2.35.3.1.3.9.2
Limit to switch on green LED
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphAirQualityLedLightsLimitYellow 1.3.6.1.4.1.5040.1.2.35.3.1.3.9.3
Limit to switch on yellow LED
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphAirQualityLedLightsLimitRed 1.3.6.1.4.1.5040.1.2.35.3.1.3.9.4
Limit to switch on red LED
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphAirQualityLoggerTimebase 1.3.6.1.4.1.5040.1.2.35.3.1.4.1
Time base of the data logger
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wtWebGraphAirQualityDatalogger-1Min(1), wtWebGraphAirQualityDatalogger-5Min(2), wtWebGraphAirQualityDatalogger-15Min(3), wtWebGraphAirQualityDatalogger-60Min(4)  

wtWebGraphAirQualityLoggerSensorSel 1.3.6.1.4.1.5040.1.2.35.3.1.4.2
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Sensor 1 Temperature Bit 1 : Sensor 2 Humidity Bit 2 : Sensor 3 VOC Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphAirQualityAlarmCount 1.3.6.1.4.1.5040.1.2.35.3.1.5.1
Number of independent alarms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..8  

wtWebGraphAirQualityAlarmIfTable 1.3.6.1.4.1.5040.1.2.35.3.1.5.2
List of alarm indices.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebGraphAirQualityAlarmIfEntry

wtWebGraphAirQualityAlarmIfEntry 1.3.6.1.4.1.5040.1.2.35.3.1.5.2.1
Numbers of the alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebGraphAirQualityAlarmIfEntry  

wtWebGraphAirQualityAlarmNo 1.3.6.1.4.1.5040.1.2.35.3.1.5.2.1.1
Alarm number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..8  

wtWebGraphAirQualityAlarmTable 1.3.6.1.4.1.5040.1.2.35.3.1.5.3
List of settings depending on the alarm number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebGraphAirQualityAlarmEntry

wtWebGraphAirQualityAlarmEntry 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1
Alarm parameters of the individual alarms.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebGraphAirQualityAlarmEntry  

wtWebGraphAirQualityAlarmTrigger 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.1
Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: Bit 0: Timer Bit 1: ColdStart Bit 2: WarmStart Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphAirQualityAlarmMin 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.2
Minimum temperature in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityAlarmMax 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.3
Maximum temperature in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityAlarmHysteresis 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.4
Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.) , in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityAlarmDelay 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.5
Alarm will be delayed by setting this time while stable alarm condition occur (time in minutes).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityAlarmInterval 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.6
Send interval for alarm messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityAlarmEnable 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.7
Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphAirQualityAlarmEMailAddr 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.8
E-Mail address for sending the alarm mail to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityAlarmMailSubject 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.9
Subject line for alarm mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityAlarmMailText 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.10
Alarm mail text: provides the current temperature; n = 1..8. provides the current time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityAlarmManagerIP 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.11
Name or IP address of the SNMP Manager which accepts the trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityAlarmTrapText 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.12
This text is sent in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityAlarmMailOptions 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.13
Binary coded options: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphAirQualityAlarmTcpIpAddr 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.14
Name or IP address of the TCP server which accepts the trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityAlarmTcpPort 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.15
Port number of the TCP server which accepts the trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebGraphAirQualityAlarmTcpText 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.16
This text is sent in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityAlarmClearMailSubject 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.17
Subject line for alarm clear mail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityAlarmClearMailText 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.18
Alarm clear mail text: provides the current temperature; n = 1..8. provides the current time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityAlarmClearTrapText 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.19
This text is sent in the trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityAlarmClearTcpText 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.20
This text is sent in the TCP trap body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityAlarmDeltaTemp 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.21
Maximum rate of change degrees/min with maximum 2 decimal places. Compared with the average of a period of 5 minutes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityAlarmRHMin 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.22
Minimum rel. Humidity in percent with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityAlarmRHMax 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.23
Maximum rel.Humidity in percent with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityAlarmRHHysteresis 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.24
Hysteresis of rel. Humidity in percent with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityAlarmAHMin 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.25
Minimum abs. Humidity in g/(m*m*m) with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityAlarmAHMax 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.26
Maximum abs. Humidity in g/(m*m*m) with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityAlarmSyslogIpAddr 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.27
IP address of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wtWebGraphAirQualityAlarmSyslogPort 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.28
Port number of the syslog server to which the Webio device should send syslog messages.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wtWebGraphAirQualityAlarmSyslogText 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.29
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityAlarmSyslogClearText 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.30
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityAlarmFtpDataPort 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.31
Local data port: 1..65535 or AUTO: the next free port will be assigned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityAlarmFtpFileName 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.32
Name of the file including path informations.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityAlarmFtpText 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.33
Message text to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityAlarmFtpClearText 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.34
Alarm clear message to store on the FTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityAlarmFtpOption 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.35
Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphAirQualityAlarmTimerCron 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.36
This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityAlarmVocMax 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.37
Maximum VOC in ppm with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityAlarmVocHysteresis 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.38
Hysteresis of VOC in ppm with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityAlarmName 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.39
Alert name
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityAlarmActive 1.3.6.1.4.1.5040.1.2.35.3.1.5.3.1.40
Alert active 1 = ON 0 = OFF
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityGraphicsBaseEnable 1.3.6.1.4.1.5040.1.2.35.3.1.6.1.1
Defines the viewing options of the graphic: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Auto scroll enable Bit 1 : Show table Bit 2 : Show graph Bit 3 : Show control buttons Bit 4 : Show config menu Bit 5-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityGraphicsBaseWidth 1.3.6.1.4.1.5040.1.2.35.3.1.6.1.2
Defines the width of the graphic in pixels.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphAirQualityGraphicsBaseHeight 1.3.6.1.4.1.5040.1.2.35.3.1.6.1.3
Defines the height of the graphic in pixels.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphAirQualityGraphicsBaseFrameColor 1.3.6.1.4.1.5040.1.2.35.3.1.6.1.4
Frame color definition in RGB.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(3)  

wtWebGraphAirQualityGraphicsBaseBackgroundColor 1.3.6.1.4.1.5040.1.2.35.3.1.6.1.5
Background color definition in RGB.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(3)  

wtWebGraphAirQualityGraphicsBasePollingrate 1.3.6.1.4.1.5040.1.2.35.3.1.6.1.6
Defines the pollingrate in seconds, which defines the refreshing intervall of the graphic.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphAirQualityGraphicsSelectDisplaySensorSel 1.3.6.1.4.1.5040.1.2.35.3.1.6.2.1
Binary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphAirQualityGraphicsSelectDisplayShowExtrem 1.3.6.1.4.1.5040.1.2.35.3.1.6.2.2
Binary coded sensor selection: only selected sensors will be shown with minima and maxima: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

wtWebGraphAirQualitySensorColorTable 1.3.6.1.4.1.5040.1.2.35.3.1.6.2.3
List of sensor colors for the praphical presentation.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebGraphAirQualitySensorColorEntry

wtWebGraphAirQualitySensorColorEntry 1.3.6.1.4.1.5040.1.2.35.3.1.6.2.3.1
Numbers of the sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebGraphAirQualitySensorColorEntry  

wtWebGraphAirQualityGraphicsSensorColor 1.3.6.1.4.1.5040.1.2.35.3.1.6.2.3.1.1
Color of the sensors at the praphical presention.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(3)  

wtWebGraphAirQualityGraphicsSelectScale 1.3.6.1.4.1.5040.1.2.35.3.1.6.2.3.1.2
Assignes one of 4 scales to a sensor: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Use Scale 1 Bit 1 : Use Scale 2 Bit 2 : Use Scale 3 Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityGraphicsScaleAutoScaleEnable 1.3.6.1.4.1.5040.1.2.35.3.1.6.3.1
Select the Auto Scale Mode: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto scale enable Bit 1 : Scale 2 Auto scale enable Bit 2 : Scale 3 Auto scale enable Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityGraphicsScaleAutoFitEnable 1.3.6.1.4.1.5040.1.2.35.3.1.6.3.2
Select the Auto Fit Mode:: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto fit enable Bit 1 : Scale 2 Auto fit enable Bit 2 : Scale 3 Auto fit enable Bit 3-7: unused
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityGraphicsScale1Min 1.3.6.1.4.1.5040.1.2.35.3.1.6.3.3
Scale 1: Minimum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebGraphAirQualityGraphicsScale2Min 1.3.6.1.4.1.5040.1.2.35.3.1.6.3.4
Scale 2: Minimum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebGraphAirQualityGraphicsScale3Min 1.3.6.1.4.1.5040.1.2.35.3.1.6.3.5
Scale 3: Minimum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebGraphAirQualityGraphicsScale4Min 1.3.6.1.4.1.5040.1.2.35.3.1.6.3.6
Scale 4: Minimum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebGraphAirQualityGraphicsScale1Max 1.3.6.1.4.1.5040.1.2.35.3.1.6.3.7
Scale 1: Maximum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebGraphAirQualityGraphicsScale2Max 1.3.6.1.4.1.5040.1.2.35.3.1.6.3.8
Scale 2: Maximum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebGraphAirQualityGraphicsScale3Max 1.3.6.1.4.1.5040.1.2.35.3.1.6.3.9
Scale 3: Maximum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebGraphAirQualityGraphicsScale4Max 1.3.6.1.4.1.5040.1.2.35.3.1.6.3.10
Scale 4: Maximum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebGraphAirQualityGraphicsScale1Unit 1.3.6.1.4.1.5040.1.2.35.3.1.6.3.11
Scale 1: Unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityGraphicsScale2Unit 1.3.6.1.4.1.5040.1.2.35.3.1.6.3.12
Scale 2: Unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityGraphicsScale3Unit 1.3.6.1.4.1.5040.1.2.35.3.1.6.3.13
Scale 3: Unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityGraphicsScale4Unit 1.3.6.1.4.1.5040.1.2.35.3.1.6.3.14
Scale 4: Unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityPortTable 1.3.6.1.4.1.5040.1.2.35.3.2.1
List of settings depending on the sensor number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WtWebGraphAirQualityPortEntry

wtWebGraphAirQualityPortEntry 1.3.6.1.4.1.5040.1.2.35.3.2.1.1
Sensor parameters for the individual sensors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WtWebGraphAirQualityPortEntry  

wtWebGraphAirQualityPortName 1.3.6.1.4.1.5040.1.2.35.3.2.1.1.1
Name of the sensor.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityPortText 1.3.6.1.4.1.5040.1.2.35.3.2.1.1.2
Description of the sensor.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityPortOffset1 1.3.6.1.4.1.5040.1.2.35.3.2.1.1.3
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityPortTemperature1 1.3.6.1.4.1.5040.1.2.35.3.2.1.1.4
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityPortOffset2 1.3.6.1.4.1.5040.1.2.35.3.2.1.1.5
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityPortTemperature2 1.3.6.1.4.1.5040.1.2.35.3.2.1.1.6
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityPortComment 1.3.6.1.4.1.5040.1.2.35.3.2.1.1.7
Offset calibration: informations of date, name of operator, reference devices.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityMfName 1.3.6.1.4.1.5040.1.2.35.3.3.1
Manufacturer company name
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityMfAddr 1.3.6.1.4.1.5040.1.2.35.3.3.2
Manufacturer address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityMfHotline 1.3.6.1.4.1.5040.1.2.35.3.3.3
Manufacturer hotline.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityMfInternet 1.3.6.1.4.1.5040.1.2.35.3.3.4
Manufacturer Internet address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityMfDeviceTyp 1.3.6.1.4.1.5040.1.2.35.3.3.5
Manufacturer device name (model number).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityMfOrderNo 1.3.6.1.4.1.5040.1.2.35.3.3.6
Manufacturer part number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityDiagErrorCount 1.3.6.1.4.1.5040.1.2.35.4.1
Number of entries in the error memory.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wtWebGraphAirQualityDiagBinaryError 1.3.6.1.4.1.5040.1.2.35.4.2
Error causes coded bit-by-bit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityDiagErrorIndex 1.3.6.1.4.1.5040.1.2.35.4.3
The value of this variable is used as an index to read an error massege from wtWebGraphAirQualityDiagErrorMessage. Errors are numbered from 1 to wtWebGraphAirQualityDiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebGraphAirQualityDiagErrorMessage.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wtWebGraphAirQualityDiagErrorMessage 1.3.6.1.4.1.5040.1.2.35.4.4
Using wtWebGraphAirQualityDiagErrorIndex as an index, the appropriate message is available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wtWebGraphAirQualityDiagErrorClear 1.3.6.1.4.1.5040.1.2.35.4.5
Writing 1 into this variable clears all diagnosis messages.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER  

wtWebGraphAirQualityAlert1 31
This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphAirQualityAlert2 32
This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphAirQualityAlert3 33
This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphAirQualityAlert4 34
This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphAirQualityAlert5 35
This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphAirQualityAlert6 36
This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphAirQualityAlert7 37
This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphAirQualityAlert8 38
This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphAirQualityAlert9 91
This SNMP trap is generated when Alarm 1 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphAirQualityAlert10 92
This SNMP trap is generated when Alarm 2 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphAirQualityAlert11 93
This SNMP trap is generated when Alarm 3 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphAirQualityAlert12 94
This SNMP trap is generated when Alarm 4 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphAirQualityAlert13 95
This SNMP trap is generated when Alarm 5 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphAirQualityAlert14 96
This SNMP trap is generated when Alarm 6 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphAirQualityAlert15 97
This SNMP trap is generated when Alarm 7 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphAirQualityAlert16 98
This SNMP trap is generated when Alarm 8 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE    

wtWebGraphAirQualityAlertDiag 110
This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE