WIENER-CRATE-MIB

File: WIENER-CRATE-MIB.mib (123345 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC

Imported symbols

OBJECT-TYPE MODULE-IDENTITY OBJECT-IDENTITY
IpAddress Integer32 Opaque
enterprises TEXTUAL-CONVENTION DisplayString
MacAddress

Defined Types

Float  
A single precision floating-point number. The semantics and encoding are identical for type 'single' defined in IEEE Standard for Binary Floating-Point, ANSI/IEEE Std 754-1985. The value is restricted to the BER serialization of the following ASN.1 type: FLOATTYPE ::= [120] IMPLICIT FloatType (note: the value 120 is the sum of '30'h and '48'h) The BER serialization of the length for values of this type must use the definite length, short encoding form. For example, the BER serialization of value 123 of type FLOATTYPE is '9f780442f60000'h. (The tag is '9f78'h; the length is '04'h; and the value is '42f60000'h.) The BER serialization of value '9f780442f60000'h of data type Opaque is '44079f780442f60000'h. (The tag is '44'h; the length is '07'h; and the value is '9f780442f60000'h.
TEXTUAL-CONVENTION    
  Opaque Size(7)  

OutputTripTime  
Special data type used for output trip time OIDs. Represents a 16 bit unsigned integer value. BER-coded as INTEGER
TEXTUAL-CONVENTION    
  Integer32 0..65535  

OutputTripAction  
Special data type used for outpot trip action OIDs.
TEXTUAL-CONVENTION    
  INTEGER ignore(0), channelOff(1), specialOff(2), allOff(3)  

System  
SEQUENCE    
  sysMainSwitch INTEGER
  sysStatus BITS
  sysVmeSysReset INTEGER
  sysHardwareReset Integer32
  sysFactoryDefaults INTEGER
  sysConfigDoMeasurementCurrent BITS
  sysOperatingTime Integer32
  sysDebugMemory8 Integer32
  sysDebugMemory16 Integer32
  sysDebugMemory32 Integer32
  sysDebug OCTET STRING
  sysDebugDisplay OCTET STRING
  sysDebugBoot OCTET STRING

OutputEntry  
SEQUENCE    
  outputIndex INTEGER
  outputName DisplayString
  outputGroup INTEGER
  outputStatus BITS
  outputMeasurementSenseVoltage Float
  outputMeasurementTerminalVoltage Float
  outputMeasurementCurrent Float
  outputMeasurementTemperature INTEGER
  outputSwitch INTEGER
  outputVoltage Float
  outputAdjustVoltage Integer32
  outputCurrent Float
  outputVoltageRiseRate Float
  outputVoltageFallRate Float
  outputSupervisionBehavior Integer32
  outputSupervisionMinSenseVoltage Float
  outputSupervisionMaxSenseVoltage Float
  outputSupervisionMaxTerminalVoltage Float
  outputSupervisionMaxCurrent Float
  outputSupervisionMaxTemperature Integer32
  outputConfigMaxSenseVoltage Float
  outputConfigMaxTerminalVoltage Float
  outputConfigMaxCurrent Float
  outputSupervisionMaxPower Float
  outputCurrentRiseRate Float
  outputCurrentFallRate Float
  outputTripTimeMaxCurrent OutputTripTime
  outputHardwareLimitVoltage Float
  outputHardwareLimitCurrent Float
  outputConfigGainSenseVoltage Float
  outputConfigOffsetSenseVoltage Float
  outputConfigGainTerminalVoltage Float
  outputConfigOffsetTerminalVoltage Float
  outputConfigGainCurrent Float
  outputConfigOffsetCurrent Float
  outputUserConfig Integer32
  outputRegulationMode INTEGER
  outputConfigMaxTemperature Integer32
  outputResistance Float
  outputTripTimeMinSenseVoltage OutputTripTime
  outputTripTimeMaxSenseVoltage OutputTripTime
  outputTripTimeMaxTerminalVoltage OutputTripTime
  outputTripTimeMaxTemperature OutputTripTime
  outputTripTimeMaxPower OutputTripTime
  outputTripTimeTimeout OutputTripTime
  outputTripActionMinSenseVoltage OutputTripAction
  outputTripActionMaxSenseVoltage OutputTripAction
  outputTripActionMaxTerminalVoltage OutputTripAction
  outputTripActionMaxCurrent OutputTripAction
  outputTripActionMaxTemperature OutputTripAction
  outputTripActionMaxPower OutputTripAction
  outputTripActionExternalInhibit OutputTripAction
  outputTripActionTimeout OutputTripAction
  outputConfigDataS OCTET STRING
  outputConfigDataU OCTET STRING

GroupsEntry  
SEQUENCE    
  groupsIndex INTEGER
  groupsSwitch INTEGER

ModuleEntry  
SEQUENCE    
  moduleIndex INTEGER
  moduleDescription OCTET STRING
  moduleAuxiliaryMeasurementVoltage Float
  moduleHardwareLimitVoltage Float
  moduleHardwareLimitCurrent Float
  moduleRampSpeedVoltage Float
  moduleRampSpeedCurrent Float
  moduleStatus BITS
  moduleEventStatus BITS
  moduleEventChannelStatus BITS
  moduleDoClear INTEGER
  moduleAuxiliaryMeasurementTemperature Float
  moduleConfigDataS OCTET STRING
  moduleConfigDataU OCTET STRING

SensorEntry  
SEQUENCE    
  sensorIndex INTEGER
  sensorTemperature INTEGER
  sensorWarningThreshold INTEGER
  sensorFailureThreshold INTEGER
  sensorAlarmThreshold INTEGER
  sensorName DisplayString
  sensorID OCTET STRING
  sensorStatus INTEGER

Snmp  
SEQUENCE    
  snmpAccessRight INTEGER
  snmpCommunityName OCTET STRING
  snmpCommunityTable SnmpCommunityEntry
  snmpPort INTEGER
  ipDynamicAddress IpAddress
  ipStaticAddress IpAddress
  macAddress MacAddress

SnmpCommunityEntry  
SEQUENCE    
  snmpAccessRight INTEGER
  snmpCommunityName OCTET STRING

Powersupply  
SEQUENCE    
  psSerialNumber DisplayString
  psOperatingTime Integer32
  psDirectAccess OCTET STRING

PsAuxiliaryEntry  
SEQUENCE    
  psAuxiliaryIndex INTEGER
  psAuxiliaryMeasurementVoltage Float
  psAuxiliaryMeasurementCurrent Float

Fantray  
SEQUENCE    
  fanSerialNumber DisplayString
  fanOperatingTime Integer32
  fanAirTemperature Integer32
  fanSwitchOffDelay INTEGER
  fanNominalSpeed Integer32
  fanMaxSpeed Integer32
  fanMinSpeed Integer32
  fanNumberOfFans Integer32
  fanConfigMaxSpeed Integer32
  fanConfigMinSpeed Integer32
  fanSpeedTable FanSpeedEntry

FanSpeedEntry  
SEQUENCE    
  fanNumber Integer32
  fanSpeed Integer32

Signal  
SEQUENCE    
  numberOfAnalogInputs Integer32
  analogInputTable AnalogInputEntry
  digitalInput BITS
  digitalOutput BITS

AnalogInputEntry  
SEQUENCE    
  analogInputIndex INTEGER
  analogMeasurementVoltage Float
  analogMeasurementCurrent Float

Defined Values

wiener 2.1.19947
Introduction of the communication.can branch.
MODULE-IDENTITY    

crate 2.1.19947.1
SNMP control for electronic crates. A crate is a complete electronic system and consists of the mechanical rack, a power supply, a fan tray and a backplane. All this things are necessary to provide an adequate housing for electronic modules (e.g. VME CPU's)
Status: current Access: not-set
OBJECT-IDENTITY    

system 2.1.19947.1.1
A collection of objects which affect the complete crate
Status: current Access: not-set
OBJECT-IDENTITY    

input 2.1.19947.1.2
All objects which are associated with the power input of the crate
Status: current Access: not-set
OBJECT-IDENTITY    

output 2.1.19947.1.3
All objects which are associated with the power output of the crate
Status: current Access: not-set
OBJECT-IDENTITY    

sensor 2.1.19947.1.4
All objects which are associated with temperature sensors in the crate
Status: current Access: not-set
OBJECT-IDENTITY    

communication 2.1.19947.1.5
All objects which affect the remote control of the crate
Status: current Access: not-set
OBJECT-IDENTITY    

powersupply 2.1.19947.1.6
All objects which are specific for the power supply of the crate
Status: current Access: not-set
OBJECT-IDENTITY    

fantray 2.1.19947.1.7
All objects which are specific for the fan tray of the crate
Status: current Access: not-set
OBJECT-IDENTITY    

rack 2.1.19947.1.8
All objects which are specific for the crate (BIN) of the crate
Status: current Access: not-set
OBJECT-IDENTITY    

signal 2.1.19947.1.9
All objects which are associated with analog/digtal input/output in the crate
Status: current Access: not-set
OBJECT-IDENTITY    

sysMainSwitch 2.1.19947.1.1.1
Read: An enumerated value which shows the current state of the crates main switch. Write: Try to switch the complete crate ON or OFF. Only the values ON or OFF are allowed.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(0), on(1)  

sysStatus 2.1.19947.1.1.2
A bit string which shows the status (health) of the complete crate. If a bit is set (1), the explanation is satisfied mainOn (0), system is switched on, individual outputs may be controlled by their specific ON/INHIBIT mainInhibit(1), external (hardware-)inhibit of the complete system localControlOnly (2), local control only (CANBUS write access denied) inputFailure (3), any input failure (e.g. power fail) outputFailure (4), any output failure, details in outputTable fantrayFailure (5), fantray failure sensorFailure (6), temperature of the external sensors too high vmeSysfail(7), VME SYSFAIL signal is active plugAndPlayIncompatible (8) wrong power supply and rack connected busReset (9) The sytem bus (e.g. VME or CPCI) reset signal is active. supplyDerating (10) The (first) system power supply has the DEG signal active. supplyFailure (11) The (first) system power supply has the FAL signal active. supplyDerating2 (12) The second system power supply has the DEG signal active. supplyFailure2 (13) The second system power supply has the FAL signal active.
Status: current Access: read-only
OBJECT-TYPE    
  BITS mainOn(0), mainInhibit(1), localControlOnly(2), inputFailure(3), outputFailure(4), fantrayFailure(5), sensorFailure(6), vmeSysfail(7), plugAndPlayIncompatible(8), busReset(9), supplyDerating(10), supplyFailure(11), supplyDerating2(12), supplyFailure2(13)  

sysVmeSysReset 2.1.19947.1.1.3
Read: Always 0. Write: Trigger the generation of the VME SYSRESET or CPIC RESET signal. This signal will be active for a time of 200 ms
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER trigger(1)  

sysHardwareReset 2.1.19947.1.1.4
Triggered a Reset via Watchdog or ResetLine.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sysFactoryDefaults 2.1.19947.1.1.5
A set operation performs a complete factory reset of ALL data stored in the controller (e.g. community names, passwords, ...).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(0), on(1)  

sysConfigDoMeasurementCurrent 2.1.19947.1.1.10
CSet the analog inputs to measure voltage or current.
Status: current Access: read-write
OBJECT-TYPE    
  BITS ch0(0), ch1(1), ch2(2), ch3(3), ch4(4), ch5(5), ch6(6), ch7(7)  

sysOperatingTime 2.1.19947.1.1.11
The time in seconds for how long the controller was in action.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sysDebugMemory8 2.1.19947.1.1.1024
Debug 16-bit memory access.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..255  

sysDebugMemory16 2.1.19947.1.1.1025
Debug 16-bit memory access.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

sysDebugMemory32 2.1.19947.1.1.1026
Debug 32-bit memory access.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -2147483648..2147483647  

sysDebug 2.1.19947.1.1.1027
Debug communication with the MPOD. This is a direct map to the ancient functions which are accessible via USB (without SLIP/SNMP).
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(520)  

sysDebugDisplay 2.1.19947.1.1.1028
Debug communication with the MPOD display.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

sysDebugBoot 2.1.19947.1.1.1029
Debug communication with the simple debug interface / bootloader.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

outputNumber 2.1.19947.1.3.1
The number of output channels of the crate.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..1999  

outputTable 2.1.19947.1.3.2
A list of output entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OutputEntry

groupsNumber 2.1.19947.1.3.3
The number of output groups of the crate.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..1999  

groupsTable 2.1.19947.1.3.4
A list of output groups entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    GroupsEntry

moduleNumber 2.1.19947.1.3.5
The number of HV/LV modules of the crate.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..10  

moduleTable 2.1.19947.1.3.6
A list of output module entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ModuleEntry

outputEntry 2.1.19947.1.3.2.1
A table row
Status: current Access: not-accessible
OBJECT-TYPE    
  OutputEntry  

outputIndex 2.1.19947.1.3.2.1.1
A unique number for each power output channel. Its value ranges between 1 and total number of output channels. This value is equivalent to the output channel number at the type label of the crate or power supply, but because the SMI index starts at 1, index 1 corresponds to U0.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER u0(1), u1(2), u2(3), u3(4), u4(5), u5(6), u6(7), u7(8), u8(9), u9(10), u10(11), u11(12), u12(13), u13(14), u14(15), u15(16), u16(17), u17(18), u18(19), u19(20), u20(21), u21(22), u22(23), u23(24), u24(25), u25(26), u26(27), u27(28), u28(29), u29(30), u30(31), u31(32), u32(33), u33(34), u34(35), u35(36), u36(37), u37(38), u38(39), u39(40), u40(41), u41(42), u42(43), u43(44), u44(45), u45(46), u46(47), u47(48), u48(49), u49(50), u50(51), u51(52), u52(53), u53(54), u54(55), u55(56), u56(57), u57(58), u58(59), u59(60), u60(61), u61(62), u62(63), u63(64), u64(65), u65(66), u66(67), u67(68), u68(69), u69(70), u70(71), u71(72), u72(73), u73(74), u74(75), u75(76), u76(77), u77(78), u78(79), u79(80), u80(81), u81(82), u82(83), u83(84), u84(85), u85(86), u86(87), u87(88), u88(89), u89(90), u90(91), u91(92), u92(93), u93(94), u94(95), u95(96), u96(97), u97(98), u98(99), u99(100), u100(101), u101(102), u102(103), u103(104), u104(105), u105(106), u106(107), u107(108), u108(109), u109(110), u110(111), u111(112), u112(113), u113(114), u114(115), u115(116), u116(117), u117(118), u118(119), u119(120), u120(121), u121(122), u122(123), u123(124), u124(125), u125(126), u126(127), u127(128), u128(129), u129(130), u130(131), u131(132), u132(133), u133(134), u134(135), u135(136), u136(137), u137(138), u138(139), u139(140), u140(141), u141(142), u142(143), u143(144), u144(145), u145(146), u146(147), u147(148), u148(149), u149(150), u150(151), u151(152), u152(153), u153(154), u154(155), u155(156), u156(157), u157(158), u158(159), u159(160), u160(161), u161(162), u162(163), u163(164), u164(165), u165(166), u166(167), u167(168), u168(169), u169(170), u170(171), u171(172), u172(173), u173(174), u174(175), u175(176), u176(177), u177(178), u178(179), u179(180), u180(181), u181(182), u182(183), u183(184), u184(185), u185(186), u186(187), u187(188), u188(189), u189(190), u190(191), u191(192), u192(193), u193(194), u194(195), u195(196), u196(197), u197(198), u198(199), u199(200), u200(201), u201(202), u202(203), u203(204), u204(205), u205(206), u206(207), u207(208), u208(209), u209(210), u210(211), u211(212), u212(213), u213(214), u214(215), u215(216), u216(217), u217(218), u218(219), u219(220), u220(221), u221(222), u222(223), u223(224), u224(225), u225(226), u226(227), u227(228), u228(229), u229(230), u230(231), u231(232), u232(233), u233(234), u234(235), u235(236), u236(237), u237(238), u238(239), u239(240), u240(241), u241(242), u242(243), u243(244), u244(245), u245(246), u246(247), u247(248), u248(249), u249(250), u250(251), u251(252), u252(253), u253(254), u254(255), u255(256), u256(257), u257(258), u258(259), u259(260), u260(261), u261(262), u262(263), u263(264), u264(265), u265(266), u266(267), u267(268), u268(269), u269(270), u270(271), u271(272), u272(273), u273(274), u274(275), u275(276), u276(277), u277(278), u278(279), u279(280), u280(281), u281(282), u282(283), u283(284), u284(285), u285(286), u286(287), u287(288), u288(289), u289(290), u290(291), u291(292), u292(293), u293(294), u294(295), u295(296), u296(297), u297(298), u298(299), u299(300), u300(301), u301(302), u302(303), u303(304), u304(305), u305(306), u306(307), u307(308), u308(309), u309(310), u310(311), u311(312), u312(313), u313(314), u314(315), u315(316), u316(317), u317(318), u318(319), u319(320), u320(321), u321(322), u322(323), u323(324), u324(325), u325(326), u326(327), u327(328), u328(329), u329(330), u330(331), u331(332), u332(333), u333(334), u334(335), u335(336), u336(337), u337(338), u338(339), u339(340), u340(341), u341(342), u342(343), u343(344), u344(345), u345(346), u346(347), u347(348), u348(349), u349(350), u350(351), u351(352), u352(353), u353(354), u354(355), u355(356), u356(357), u357(358), u358(359), u359(360), u360(361), u361(362), u362(363), u363(364), u364(365), u365(366), u366(367), u367(368), u368(369), u369(370), u370(371), u371(372), u372(373), u373(374), u374(375), u375(376), u376(377), u377(378), u378(379), u379(380), u380(381), u381(382), u382(383), u383(384), u384(385), u385(386), u386(387), u387(388), u388(389), u389(390), u390(391), u391(392), u392(393), u393(394), u394(395), u395(396), u396(397), u397(398), u398(399), u399(400), u400(401), u401(402), u402(403), u403(404), u404(405), u405(406), u406(407), u407(408), u408(409), u409(410), u410(411), u411(412), u412(413), u413(414), u414(415), u415(416), u416(417), u417(418), u418(419), u419(420), u420(421), u421(422), u422(423), u423(424), u424(425), u425(426), u426(427), u427(428), u428(429), u429(430), u430(431), u431(432), u432(433), u433(434), u434(435), u435(436), u436(437), u437(438), u438(439), u439(440), u440(441), u441(442), u442(443), u443(444), u444(445), u445(446), u446(447), u447(448), u448(449), u449(450), u450(451), u451(452), u452(453), u453(454), u454(455), u455(456), u456(457), u457(458), u458(459), u459(460), u460(461), u461(462), u462(463), u463(464), u464(465), u465(466), u466(467), u467(468), u468(469), u469(470), u470(471), u471(472), u472(473), u473(474), u474(475), u475(476), u476(477), u477(478), u478(479), u479(480), u480(481), u481(482), u482(483), u483(484), u484(485), u485(486), u486(487), u487(488), u488(489), u489(490), u490(491), u491(492), u492(493), u493(494), u494(495), u495(496), u496(497), u497(498), u498(499), u499(500), u500(501), u501(502), u502(503), u503(504), u504(505), u505(506), u506(507), u507(508), u508(509), u509(510), u510(511), u511(512), u512(513), u513(514), u514(515), u515(516), u516(517), u517(518), u518(519), u519(520), u520(521), u521(522), u522(523), u523(524), u524(525), u525(526), u526(527), u527(528), u528(529), u529(530), u530(531), u531(532), u532(533), u533(534), u534(535), u535(536), u536(537), u537(538), u538(539), u539(540), u540(541), u541(542), u542(543), u543(544), u544(545), u545(546), u546(547), u547(548), u548(549), u549(550), u550(551), u551(552), u552(553), u553(554), u554(555), u555(556), u556(557), u557(558), u558(559), u559(560), u560(561), u561(562), u562(563), u563(564), u564(565), u565(566), u566(567), u567(568), u568(569), u569(570), u570(571), u571(572), u572(573), u573(574), u574(575), u575(576), u576(577), u577(578), u578(579), u579(580), u580(581), u581(582), u582(583), u583(584), u584(585), u585(586), u586(587), u587(588), u588(589), u589(590), u590(591), u591(592), u592(593), u593(594), u594(595), u595(596), u596(597), u597(598), u598(599), u599(600), u600(601), u601(602), u602(603), u603(604), u604(605), u605(606), u606(607), u607(608), u608(609), u609(610), u610(611), u611(612), u612(613), u613(614), u614(615), u615(616), u616(617), u617(618), u618(619), u619(620), u620(621), u621(622), u622(623), u623(624), u624(625), u625(626), u626(627), u627(628), u628(629), u629(630), u630(631), u631(632), u632(633), u633(634), u634(635), u635(636), u636(637), u637(638), u638(639), u639(640), u640(641), u641(642), u642(643), u643(644), u644(645), u645(646), u646(647), u647(648), u648(649), u649(650), u650(651), u651(652), u652(653), u653(654), u654(655), u655(656), u656(657), u657(658), u658(659), u659(660), u660(661), u661(662), u662(663), u663(664), u664(665), u665(666), u666(667), u667(668), u668(669), u669(670), u670(671), u671(672), u672(673), u673(674), u674(675), u675(676), u676(677), u677(678), u678(679), u679(680), u680(681), u681(682), u682(683), u683(684), u684(685), u685(686), u686(687), u687(688), u688(689), u689(690), u690(691), u691(692), u692(693), u693(694), u694(695), u695(696), u696(697), u697(698), u698(699), u699(700), u700(701), u701(702), u702(703), u703(704), u704(705), u705(706), u706(707), u707(708), u708(709), u709(710), u710(711), u711(712), u712(713), u713(714), u714(715), u715(716), u716(717), u717(718), u718(719), u719(720), u720(721), u721(722), u722(723), u723(724), u724(725), u725(726), u726(727), u727(728), u728(729), u729(730), u730(731), u731(732), u732(733), u733(734), u734(735), u735(736), u736(737), u737(738), u738(739), u739(740), u740(741), u741(742), u742(743), u743(744), u744(745), u745(746), u746(747), u747(748), u748(749), u749(750), u750(751), u751(752), u752(753), u753(754), u754(755), u755(756), u756(757), u757(758), u758(759), u759(760), u760(761), u761(762), u762(763), u763(764), u764(765), u765(766), u766(767), u767(768), u768(769), u769(770), u770(771), u771(772), u772(773), u773(774), u774(775), u775(776), u776(777), u777(778), u778(779), u779(780), u780(781), u781(782), u782(783), u783(784), u784(785), u785(786), u786(787), u787(788), u788(789), u789(790), u790(791), u791(792), u792(793), u793(794), u794(795), u795(796), u796(797), u797(798), u798(799), u799(800), u800(801), u801(802), u802(803), u803(804), u804(805), u805(806), u806(807), u807(808), u808(809), u809(810), u810(811), u811(812), u812(813), u813(814), u814(815), u815(816), u816(817), u817(818), u818(819), u819(820), u820(821), u821(822), u822(823), u823(824), u824(825), u825(826), u826(827), u827(828), u828(829), u829(830), u830(831), u831(832), u832(833), u833(834), u834(835), u835(836), u836(837), u837(838), u838(839), u839(840), u840(841), u841(842), u842(843), u843(844), u844(845), u845(846), u846(847), u847(848), u848(849), u849(850), u850(851), u851(852), u852(853), u853(854), u854(855), u855(856), u856(857), u857(858), u858(859), u859(860), u860(861), u861(862), u862(863), u863(864), u864(865), u865(866), u866(867), u867(868), u868(869), u869(870), u870(871), u871(872), u872(873), u873(874), u874(875), u875(876), u876(877), u877(878), u878(879), u879(880), u880(881), u881(882), u882(883), u883(884), u884(885), u885(886), u886(887), u887(888), u888(889), u889(890), u890(891), u891(892), u892(893), u893(894), u894(895), u895(896), u896(897), u897(898), u898(899), u899(900), u900(901), u901(902), u902(903), u903(904), u904(905), u905(906), u906(907), u907(908), u908(909), u909(910), u910(911), u911(912), u912(913), u913(914), u914(915), u915(916), u916(917), u917(918), u918(919), u919(920), u920(921), u921(922), u922(923), u923(924), u924(925), u925(926), u926(927), u927(928), u928(929), u929(930), u930(931), u931(932), u932(933), u933(934), u934(935), u935(936), u936(937), u937(938), u938(939), u939(940), u940(941), u941(942), u942(943), u943(944), u944(945), u945(946), u946(947), u947(948), u948(949), u949(950), u950(951), u951(952), u952(953), u953(954), u954(955), u955(956), u956(957), u957(958), u958(959), u959(960), u960(961), u961(962), u962(963), u963(964), u964(965), u965(966), u966(967), u967(968), u968(969), u969(970), u970(971), u971(972), u972(973), u973(974), u974(975), u975(976), u976(977), u977(978), u978(979), u979(980), u980(981), u981(982), u982(983), u983(984), u984(985), u985(986), u986(987), u987(988), u988(989), u989(990), u990(991), u991(992), u992(993), u993(994), u994(995), u995(996), u996(997), u997(998), u998(999), u999(1000), u1000(1001), u1001(1002), u1002(1003), u1003(1004), u1004(1005), u1005(1006), u1006(1007), u1007(1008), u1008(1009), u1009(1010), u1010(1011), u1011(1012), u1012(1013), u1013(1014), u1014(1015), u1015(1016), u1016(1017), u1017(1018), u1018(1019), u1019(1020), u1020(1021), u1021(1022), u1022(1023), u1023(1024), u1024(1025), u1025(1026), u1026(1027), u1027(1028), u1028(1029), u1029(1030), u1030(1031), u1031(1032), u1032(1033), u1033(1034), u1034(1035), u1035(1036), u1036(1037), u1037(1038), u1038(1039), u1039(1040), u1040(1041), u1041(1042), u1042(1043), u1043(1044), u1044(1045), u1045(1046), u1046(1047), u1047(1048), u1048(1049), u1049(1050), u1050(1051), u1051(1052), u1052(1053), u1053(1054), u1054(1055), u1055(1056), u1056(1057), u1057(1058), u1058(1059), u1059(1060), u1060(1061), u1061(1062), u1062(1063), u1063(1064), u1064(1065), u1065(1066), u1066(1067), u1067(1068), u1068(1069), u1069(1070), u1070(1071), u1071(1072), u1072(1073), u1073(1074), u1074(1075), u1075(1076), u1076(1077), u1077(1078), u1078(1079), u1079(1080), u1080(1081), u1081(1082), u1082(1083), u1083(1084), u1084(1085), u1085(1086), u1086(1087), u1087(1088), u1088(1089), u1089(1090), u1090(1091), u1091(1092), u1092(1093), u1093(1094), u1094(1095), u1095(1096), u1096(1097), u1097(1098), u1098(1099), u1099(1100), u1100(1101), u1101(1102), u1102(1103), u1103(1104), u1104(1105), u1105(1106), u1106(1107), u1107(1108), u1108(1109), u1109(1110), u1110(1111), u1111(1112), u1112(1113), u1113(1114), u1114(1115), u1115(1116), u1116(1117), u1117(1118), u1118(1119), u1119(1120), u1120(1121), u1121(1122), u1122(1123), u1123(1124), u1124(1125), u1125(1126), u1126(1127), u1127(1128), u1128(1129), u1129(1130), u1130(1131), u1131(1132), u1132(1133), u1133(1134), u1134(1135), u1135(1136), u1136(1137), u1137(1138), u1138(1139), u1139(1140), u1140(1141), u1141(1142), u1142(1143), u1143(1144), u1144(1145), u1145(1146), u1146(1147), u1147(1148), u1148(1149), u1149(1150), u1150(1151), u1151(1152), u1152(1153), u1153(1154), u1154(1155), u1155(1156), u1156(1157), u1157(1158), u1158(1159), u1159(1160), u1160(1161), u1161(1162), u1162(1163), u1163(1164), u1164(1165), u1165(1166), u1166(1167), u1167(1168), u1168(1169), u1169(1170), u1170(1171), u1171(1172), u1172(1173), u1173(1174), u1174(1175), u1175(1176), u1176(1177), u1177(1178), u1178(1179), u1179(1180), u1180(1181), u1181(1182), u1182(1183), u1183(1184), u1184(1185), u1185(1186), u1186(1187), u1187(1188), u1188(1189), u1189(1190), u1190(1191), u1191(1192), u1192(1193), u1193(1194), u1194(1195), u1195(1196), u1196(1197), u1197(1198), u1198(1199), u1199(1200), u1200(1201), u1201(1202), u1202(1203), u1203(1204), u1204(1205), u1205(1206), u1206(1207), u1207(1208), u1208(1209), u1209(1210), u1210(1211), u1211(1212), u1212(1213), u1213(1214), u1214(1215), u1215(1216), u1216(1217), u1217(1218), u1218(1219), u1219(1220), u1220(1221), u1221(1222), u1222(1223), u1223(1224), u1224(1225), u1225(1226), u1226(1227), u1227(1228), u1228(1229), u1229(1230), u1230(1231), u1231(1232), u1232(1233), u1233(1234), u1234(1235), u1235(1236), u1236(1237), u1237(1238), u1238(1239), u1239(1240), u1240(1241), u1241(1242), u1242(1243), u1243(1244), u1244(1245), u1245(1246), u1246(1247), u1247(1248), u1248(1249), u1249(1250), u1250(1251), u1251(1252), u1252(1253), u1253(1254), u1254(1255), u1255(1256), u1256(1257), u1257(1258), u1258(1259), u1259(1260), u1260(1261), u1261(1262), u1262(1263), u1263(1264), u1264(1265), u1265(1266), u1266(1267), u1267(1268), u1268(1269), u1269(1270), u1270(1271), u1271(1272), u1272(1273), u1273(1274), u1274(1275), u1275(1276), u1276(1277), u1277(1278), u1278(1279), u1279(1280), u1280(1281), u1281(1282), u1282(1283), u1283(1284), u1284(1285), u1285(1286), u1286(1287), u1287(1288), u1288(1289), u1289(1290), u1290(1291), u1291(1292), u1292(1293), u1293(1294), u1294(1295), u1295(1296), u1296(1297), u1297(1298), u1298(1299), u1299(1300), u1300(1301), u1301(1302), u1302(1303), u1303(1304), u1304(1305), u1305(1306), u1306(1307), u1307(1308), u1308(1309), u1309(1310), u1310(1311), u1311(1312), u1312(1313), u1313(1314), u1314(1315), u1315(1316), u1316(1317), u1317(1318), u1318(1319), u1319(1320), u1320(1321), u1321(1322), u1322(1323), u1323(1324), u1324(1325), u1325(1326), u1326(1327), u1327(1328), u1328(1329), u1329(1330), u1330(1331), u1331(1332), u1332(1333), u1333(1334), u1334(1335), u1335(1336), u1336(1337), u1337(1338), u1338(1339), u1339(1340), u1340(1341), u1341(1342), u1342(1343), u1343(1344), u1344(1345), u1345(1346), u1346(1347), u1347(1348), u1348(1349), u1349(1350), u1350(1351), u1351(1352), u1352(1353), u1353(1354), u1354(1355), u1355(1356), u1356(1357), u1357(1358), u1358(1359), u1359(1360), u1360(1361), u1361(1362), u1362(1363), u1363(1364), u1364(1365), u1365(1366), u1366(1367), u1367(1368), u1368(1369), u1369(1370), u1370(1371), u1371(1372), u1372(1373), u1373(1374), u1374(1375), u1375(1376), u1376(1377), u1377(1378), u1378(1379), u1379(1380), u1380(1381), u1381(1382), u1382(1383), u1383(1384), u1384(1385), u1385(1386), u1386(1387), u1387(1388), u1388(1389), u1389(1390), u1390(1391), u1391(1392), u1392(1393), u1393(1394), u1394(1395), u1395(1396), u1396(1397), u1397(1398), u1398(1399), u1399(1400), u1400(1401), u1401(1402), u1402(1403), u1403(1404), u1404(1405), u1405(1406), u1406(1407), u1407(1408), u1408(1409), u1409(1410), u1410(1411), u1411(1412), u1412(1413), u1413(1414), u1414(1415), u1415(1416), u1416(1417), u1417(1418), u1418(1419), u1419(1420), u1420(1421), u1421(1422), u1422(1423), u1423(1424), u1424(1425), u1425(1426), u1426(1427), u1427(1428), u1428(1429), u1429(1430), u1430(1431), u1431(1432), u1432(1433), u1433(1434), u1434(1435), u1435(1436), u1436(1437), u1437(1438), u1438(1439), u1439(1440), u1440(1441), u1441(1442), u1442(1443), u1443(1444), u1444(1445), u1445(1446), u1446(1447), u1447(1448), u1448(1449), u1449(1450), u1450(1451), u1451(1452), u1452(1453), u1453(1454), u1454(1455), u1455(1456), u1456(1457), u1457(1458), u1458(1459), u1459(1460), u1460(1461), u1461(1462), u1462(1463), u1463(1464), u1464(1465), u1465(1466), u1466(1467), u1467(1468), u1468(1469), u1469(1470), u1470(1471), u1471(1472), u1472(1473), u1473(1474), u1474(1475), u1475(1476), u1476(1477), u1477(1478), u1478(1479), u1479(1480), u1480(1481), u1481(1482), u1482(1483), u1483(1484), u1484(1485), u1485(1486), u1486(1487), u1487(1488), u1488(1489), u1489(1490), u1490(1491), u1491(1492), u1492(1493), u1493(1494), u1494(1495), u1495(1496), u1496(1497), u1497(1498), u1498(1499), u1499(1500), u1500(1501), u1501(1502), u1502(1503), u1503(1504), u1504(1505), u1505(1506), u1506(1507), u1507(1508), u1508(1509), u1509(1510), u1510(1511), u1511(1512), u1512(1513), u1513(1514), u1514(1515), u1515(1516), u1516(1517), u1517(1518), u1518(1519), u1519(1520), u1520(1521), u1521(1522), u1522(1523), u1523(1524), u1524(1525), u1525(1526), u1526(1527), u1527(1528), u1528(1529), u1529(1530), u1530(1531), u1531(1532), u1532(1533), u1533(1534), u1534(1535), u1535(1536), u1536(1537), u1537(1538), u1538(1539), u1539(1540), u1540(1541), u1541(1542), u1542(1543), u1543(1544), u1544(1545), u1545(1546), u1546(1547), u1547(1548), u1548(1549), u1549(1550), u1550(1551), u1551(1552), u1552(1553), u1553(1554), u1554(1555), u1555(1556), u1556(1557), u1557(1558), u1558(1559), u1559(1560), u1560(1561), u1561(1562), u1562(1563), u1563(1564), u1564(1565), u1565(1566), u1566(1567), u1567(1568), u1568(1569), u1569(1570), u1570(1571), u1571(1572), u1572(1573), u1573(1574), u1574(1575), u1575(1576), u1576(1577), u1577(1578), u1578(1579), u1579(1580), u1580(1581), u1581(1582), u1582(1583), u1583(1584), u1584(1585), u1585(1586), u1586(1587), u1587(1588), u1588(1589), u1589(1590), u1590(1591), u1591(1592), u1592(1593), u1593(1594), u1594(1595), u1595(1596), u1596(1597), u1597(1598), u1598(1599), u1599(1600), u1600(1601), u1601(1602), u1602(1603), u1603(1604), u1604(1605), u1605(1606), u1606(1607), u1607(1608), u1608(1609), u1609(1610), u1610(1611), u1611(1612), u1612(1613), u1613(1614), u1614(1615), u1615(1616), u1616(1617), u1617(1618), u1618(1619), u1619(1620), u1620(1621), u1621(1622), u1622(1623), u1623(1624), u1624(1625), u1625(1626), u1626(1627), u1627(1628), u1628(1629), u1629(1630), u1630(1631), u1631(1632), u1632(1633), u1633(1634), u1634(1635), u1635(1636), u1636(1637), u1637(1638), u1638(1639), u1639(1640), u1640(1641), u1641(1642), u1642(1643), u1643(1644), u1644(1645), u1645(1646), u1646(1647), u1647(1648), u1648(1649), u1649(1650), u1650(1651), u1651(1652), u1652(1653), u1653(1654), u1654(1655), u1655(1656), u1656(1657), u1657(1658), u1658(1659), u1659(1660), u1660(1661), u1661(1662), u1662(1663), u1663(1664), u1664(1665), u1665(1666), u1666(1667), u1667(1668), u1668(1669), u1669(1670), u1670(1671), u1671(1672), u1672(1673), u1673(1674), u1674(1675), u1675(1676), u1676(1677), u1677(1678), u1678(1679), u1679(1680), u1680(1681), u1681(1682), u1682(1683), u1683(1684), u1684(1685), u1685(1686), u1686(1687), u1687(1688), u1688(1689), u1689(1690), u1690(1691), u1691(1692), u1692(1693), u1693(1694), u1694(1695), u1695(1696), u1696(1697), u1697(1698), u1698(1699), u1699(1700), u1700(1701), u1701(1702), u1702(1703), u1703(1704), u1704(1705), u1705(1706), u1706(1707), u1707(1708), u1708(1709), u1709(1710), u1710(1711), u1711(1712), u1712(1713), u1713(1714), u1714(1715), u1715(1716), u1716(1717), u1717(1718), u1718(1719), u1719(1720), u1720(1721), u1721(1722), u1722(1723), u1723(1724), u1724(1725), u1725(1726), u1726(1727), u1727(1728), u1728(1729), u1729(1730), u1730(1731), u1731(1732), u1732(1733), u1733(1734), u1734(1735), u1735(1736), u1736(1737), u1737(1738), u1738(1739), u1739(1740), u1740(1741), u1741(1742), u1742(1743), u1743(1744), u1744(1745), u1745(1746), u1746(1747), u1747(1748), u1748(1749), u1749(1750), u1750(1751), u1751(1752), u1752(1753), u1753(1754), u1754(1755), u1755(1756), u1756(1757), u1757(1758), u1758(1759), u1759(1760), u1760(1761), u1761(1762), u1762(1763), u1763(1764), u1764(1765), u1765(1766), u1766(1767), u1767(1768), u1768(1769), u1769(1770), u1770(1771), u1771(1772), u1772(1773), u1773(1774), u1774(1775), u1775(1776), u1776(1777), u1777(1778), u1778(1779), u1779(1780), u1780(1781), u1781(1782), u1782(1783), u1783(1784), u1784(1785), u1785(1786), u1786(1787), u1787(1788), u1788(1789), u1789(1790), u1790(1791), u1791(1792), u1792(1793), u1793(1794), u1794(1795), u1795(1796), u1796(1797), u1797(1798), u1798(1799), u1799(1800), u1800(1801), u1801(1802), u1802(1803), u1803(1804), u1804(1805), u1805(1806), u1806(1807), u1807(1808), u1808(1809), u1809(1810), u1810(1811), u1811(1812), u1812(1813), u1813(1814), u1814(1815), u1815(1816), u1816(1817), u1817(1818), u1818(1819), u1819(1820), u1820(1821), u1821(1822), u1822(1823), u1823(1824), u1824(1825), u1825(1826), u1826(1827), u1827(1828), u1828(1829), u1829(1830), u1830(1831), u1831(1832), u1832(1833), u1833(1834), u1834(1835), u1835(1836), u1836(1837), u1837(1838), u1838(1839), u1839(1840), u1840(1841), u1841(1842), u1842(1843), u1843(1844), u1844(1845), u1845(1846), u1846(1847), u1847(1848), u1848(1849), u1849(1850), u1850(1851), u1851(1852), u1852(1853), u1853(1854), u1854(1855), u1855(1856), u1856(1857), u1857(1858), u1858(1859), u1859(1860), u1860(1861), u1861(1862), u1862(1863), u1863(1864), u1864(1865), u1865(1866), u1866(1867), u1867(1868), u1868(1869), u1869(1870), u1870(1871), u1871(1872), u1872(1873), u1873(1874), u1874(1875), u1875(1876), u1876(1877), u1877(1878), u1878(1879), u1879(1880), u1880(1881), u1881(1882), u1882(1883), u1883(1884), u1884(1885), u1885(1886), u1886(1887), u1887(1888), u1888(1889), u1889(1890), u1890(1891), u1891(1892), u1892(1893), u1893(1894), u1894(1895), u1895(1896), u1896(1897), u1897(1898), u1898(1899), u1899(1900), u1900(1901), u1901(1902), u1902(1903), u1903(1904), u1904(1905), u1905(1906), u1906(1907), u1907(1908), u1908(1909), u1909(1910), u1910(1911), u1911(1912), u1912(1913), u1913(1914), u1914(1915), u1915(1916), u1916(1917), u1917(1918), u1918(1919), u1919(1920), u1920(1921), u1921(1922), u1922(1923), u1923(1924), u1924(1925), u1925(1926), u1926(1927), u1927(1928), u1928(1929), u1929(1930), u1930(1931), u1931(1932), u1932(1933), u1933(1934), u1934(1935), u1935(1936), u1936(1937), u1937(1938), u1938(1939), u1939(1940), u1940(1941), u1941(1942), u1942(1943), u1943(1944), u1944(1945), u1945(1946), u1946(1947), u1947(1948), u1948(1949), u1949(1950), u1950(1951), u1951(1952), u1952(1953), u1953(1954), u1954(1955), u1955(1956), u1956(1957), u1957(1958), u1958(1959), u1959(1960), u1960(1961), u1961(1962), u1962(1963), u1963(1964), u1964(1965), u1965(1966), u1966(1967), u1967(1968), u1968(1969), u1969(1970), u1970(1971), u1971(1972), u1972(1973), u1973(1974), u1974(1975), u1975(1976), u1976(1977), u1977(1978), u1978(1979), u1979(1980), u1980(1981), u1981(1982), u1982(1983), u1983(1984), u1984(1985), u1985(1986), u1986(1987), u1987(1988), u1988(1989), u1989(1990), u1990(1991), u1991(1992), u1992(1993), u1993(1994), u1994(1995), u1995(1996), u1996(1997), u1997(1998), u1998(1999), u1999(2000)  

outputName 2.1.19947.1.3.2.1.2
A textual string containing a short name of the output. If the crate is equipped with an alphanumeric display, this string is shown to identify a output channel.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..4)  

outputGroup 2.1.19947.1.3.2.1.3
The group number (1...63) assigned to each channel. If commands shall be sent to all channels with a specific group number (e.g. with the groupsSwitch command defined below), additional bits can be added to the group number: HLgggggg g: Group number (1...63) L: Mask bit: 1: high voltage channels only, no low voltage channels H: Mask bit: 1: low voltage channels only, no high voltage channels Special groups: 0: all (LV+HV) channels 0x40: all, but no LV channels 0x80: all, but no HV channels
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..63  

outputStatus 2.1.19947.1.3.2.1.4
A bit string which shows the status (health and operating conditions) of one output channel. If a bit is set (1), the explanation is satisfied: outputOn (0), output channel is on outputInhibit(1), external (hardware-)inhibit of the output channel outputFailureMinSenseVoltage (2) Supervision limit hurt: Sense voltage is too low outputFailureMaxSenseVoltage (3), Supervision limit hurt: Sense voltage is too high outputFailureMaxTerminalVoltage (4), Supervision limit hurt: Terminal voltage is too high outputFailureMaxCurrent (5), Supervision limit hurt: Current is too high outputFailureMaxTemperature (6), Supervision limit hurt: Heat sink temperature is too high outputFailureMaxPower (7), Supervision limit hurt: Output power is too high outputFailureTimeout (9), Communication timeout between output channel and main control outputCurrentLimited (10), Current limiting is active (constant current mode) outputRampUp (11), Output voltage is increasing (e.g. after switch on) outputRampDown (12), Output voltage is decreasing (e.g. after switch off) outputEnableKill (13), EnableKill is active outputEmergencyOff (14), EmergencyOff event is active outputAdjusting (15), Fine adjustment is working outputConstantVoltage (16), Voltage control (constant voltage mode) outputLowCurrentRange (17), The channel is operating in the low current measurement range outputCurrentBoundsExceeded (18), Output current is out of bounds outputFailureCurrentLimit (19) Hardware current limit (EHS) / trip (EDS, EBS) was exceeded
Status: current Access: read-only
OBJECT-TYPE    
  BITS outputOn(0), outputInhibit(1), outputFailureMinSenseVoltage(2), outputFailureMaxSenseVoltage(3), outputFailureMaxTerminalVoltage(4), outputFailureMaxCurrent(5), outputFailureMaxTemperature(6), outputFailureMaxPower(7), outputFailureTimeout(9), outputCurrentLimited(10), outputRampUp(11), outputRampDown(12), outputEnableKill(13), outputEmergencyOff(14), outputAdjusting(15), outputConstantVoltage(16), outputLowCurrentRange(17), outputCurrentBoundsExceeded(18), outputFailureCurrentLimit(19)  

outputMeasurementSenseVoltage 2.1.19947.1.3.2.1.5
The measured voltage at the sense input lines.
Status: current Access: read-only
OBJECT-TYPE    
  Float  

outputMeasurementTerminalVoltage 2.1.19947.1.3.2.1.6
The measured voltage at the output terminals.
Status: current Access: read-only
OBJECT-TYPE    
  Float  

outputMeasurementCurrent 2.1.19947.1.3.2.1.7
The measured output current.
Status: current Access: read-only
OBJECT-TYPE    
  Float  

outputMeasurementTemperature 2.1.19947.1.3.2.1.8
The measured temperature of the power module.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ok(-128), failure(127)  

outputSwitch 2.1.19947.1.3.2.1.9
Read: An enumerated value which shows the current state of the output channel. Write: Change the state of the channel. If the channel is On, and the write value is Off, then the channel will switch Off. If the channel is Off, and the write value is On, and if no other signals (mainInhibit, outputInhibit, outputEmergencyOff or outputFailureMaxCurrent) are active, then the channel will switch on. If the write value is resetEmergencyOff, then the channel will leave the state EmergencyOff. A write of clearEvents is necessary before the voltage can ramp up again. If the write value is setEmergencyOff, then the channel will have the state EmergencyOff, which means that the High Voltage will switch off without a ramp and reset of the outputVoltage to null volt. If the write value is clearEvents, then all failure messages of the outputStatus will be reset (all channel events, all module events and the state emergencyOff).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(0), on(1), resetEmergencyOff(2), setEmergencyOff(3), clearEvents(10), setVoltageRippleMeasurementOff(20), setVoltageMeasurementOn(21), setRippleMeasurementOn(22), setVoltageRippleMeasurementOn(23)  

outputVoltage 2.1.19947.1.3.2.1.10
The nominal output voltage of the channel.
Status: current Access: read-write
OBJECT-TYPE    
  Float  

outputAdjustVoltage 2.1.19947.1.3.2.1.11
A posibillity to make small changes of the output voltage.
Status: obsolete Access: read-write
OBJECT-TYPE    
  Integer32 -128..127  

outputCurrent 2.1.19947.1.3.2.1.12
The current limit of the channel.
Status: current Access: read-write
OBJECT-TYPE    
  Float  

outputVoltageRiseRate 2.1.19947.1.3.2.1.13
Voltage Fall Slew Rate [V/s]. The slew rate of the output voltage if it increases (after switch on or if the Voltage has been changed).
Status: current Access: read-write
OBJECT-TYPE    
  Float  

outputVoltageFallRate 2.1.19947.1.3.2.1.14
Voltage Rise Slew Rate [V/s]. The slew rate of the output voltage if it decreases (after switch off or if the Voltage has been changed).
Status: current Access: read-write
OBJECT-TYPE    
  Float  

outputSupervisionBehavior 2.1.19947.1.3.2.1.15
A bit field packed into an integer which define the behavior of the output channel / power supply after failures. For each supervision value, a two-bit field exists. The enumeration of this value (..L+..H*2) is: WIENER LV devices 0 ignore the failure 1 switch off this channel 2 switch off all channels with the same group number 3 switch off the complete crate. iseg HV devices 0 ignore the failure 1 switch off this channel by ramp down the voltage 2 switch off this channel by a emergencyOff 3 switch off the whole board of the HV module by emergencyOff. The position of the bit fields in the integer value are: Bit 0, 1: outputFailureMinSenseVoltage Bit 2, 3: outputFailureMaxSenseVoltage Bit 4, 5: outputFailureMaxTerminalVoltage Bit 6, 7: outputFailureMaxCurrent Bit 8, 9: outputFailureMaxTemperature Bit 10, 11: outputFailureMaxPower Bit 12, 13: outputFailureInhibit Bit 14, 15: outputFailureTimeout
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

outputSupervisionMinSenseVoltage 2.1.19947.1.3.2.1.16
If the measured sense voltage is below this value, the power supply performs the function defined by SupervisionAction.
Status: current Access: read-write
OBJECT-TYPE    
  Float  

outputSupervisionMaxSenseVoltage 2.1.19947.1.3.2.1.17
If the measured sense voltage is above this value, the power supply performs the function defined by SupervisionAction.
Status: current Access: read-write
OBJECT-TYPE    
  Float  

outputSupervisionMaxTerminalVoltage 2.1.19947.1.3.2.1.18
If the measured voltage at the power supply output terminals is above this value, the power supply performs the function defined by SupervisionAction.
Status: current Access: read-write
OBJECT-TYPE    
  Float  

outputSupervisionMaxCurrent 2.1.19947.1.3.2.1.19
If the measured current is above this value, the power supply performs the function defined by SupervisionAction.
Status: current Access: read-write
OBJECT-TYPE    
  Float  

outputSupervisionMaxTemperature 2.1.19947.1.3.2.1.20
If the measured module temperature is above this value, the power supply performs the function defined by SupervisionAction.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

outputConfigMaxSenseVoltage 2.1.19947.1.3.2.1.21
The maximum possible value of the sense voltage
Status: current Access: read-write
OBJECT-TYPE    
  Float  

outputConfigMaxTerminalVoltage 2.1.19947.1.3.2.1.22
The maximum possible value of the terminal voltage
Status: current Access: read-write
OBJECT-TYPE    
  Float  

outputConfigMaxCurrent 2.1.19947.1.3.2.1.23
The maximum possible value of the output current
Status: current Access: read-write
OBJECT-TYPE    
  Float  

outputSupervisionMaxPower 2.1.19947.1.3.2.1.24
If the measured power (measured current * measured terminal voltage) is above this value, the power supply performs the function defined by SupervisionAction.
Status: current Access: read-write
OBJECT-TYPE    
  Float  

outputCurrentRiseRate 2.1.19947.1.3.2.1.25
Current Fall Slew Rate [A/s]. The slew rate of the output current if it increases (after switch on or if the Current has been changed).
Status: current Access: read-write
OBJECT-TYPE    
  Float  

outputCurrentFallRate 2.1.19947.1.3.2.1.26
Current Rise Slew Rate [A/s]. The slew rate of the output current if it decreases (after switch off or if the Current has been changed).
Status: current Access: read-write
OBJECT-TYPE    
  Float  

outputTripTimeMaxCurrent 2.1.19947.1.3.2.1.27
Minimum time the outputSupervisionMaxCurrent threshold must be violated to activate the trip action [ms]. The trip action is defined in outputSupervisionBehavior (bit field outputFailureMaxCurrent) or the new outputTripActionMaxCurrent.
Status: current Access: read-write
OBJECT-TYPE    
  OutputTripTime  

outputHardwareLimitVoltage 2.1.19947.1.3.2.1.28
Hardware Voltage Limit [V]. Potentiometer to adjust the global hardware voltage limit (for all channels of a module).
Status: current Access: read-only
OBJECT-TYPE    
  Float  

outputHardwareLimitCurrent 2.1.19947.1.3.2.1.29
Hardware Current Limit [A]. Potentiometer to adjust the global hardware current limit (for all channels of a module).
Status: current Access: read-only
OBJECT-TYPE    
  Float  

outputConfigGainSenseVoltage 2.1.19947.1.3.2.1.30
The gain value of the sense voltage
Status: current Access: read-write
OBJECT-TYPE    
  Float  

outputConfigOffsetSenseVoltage 2.1.19947.1.3.2.1.31
The offset value of the sense voltage
Status: current Access: read-write
OBJECT-TYPE    
  Float  

outputConfigGainTerminalVoltage 2.1.19947.1.3.2.1.32
The gain value of the sense voltage
Status: current Access: read-write
OBJECT-TYPE    
  Float  

outputConfigOffsetTerminalVoltage 2.1.19947.1.3.2.1.33
The offset value of the sense voltage
Status: current Access: read-write
OBJECT-TYPE    
  Float  

outputConfigGainCurrent 2.1.19947.1.3.2.1.34
The gain value of the sense voltage
Status: current Access: read-write
OBJECT-TYPE    
  Float  

outputConfigOffsetCurrent 2.1.19947.1.3.2.1.35
The offset value of the sense voltage
Status: current Access: read-write
OBJECT-TYPE    
  Float  

outputUserConfig 2.1.19947.1.3.2.1.37
Definition of user-changeable items. A bit field packed into an integer which define the behavior of the output channel. Usable for WIENER LV devices only. The position of the bit fields in the integer value are: Bit 0: Voltage ramping at switch off: 0: Ramp down at switch off. 1: No ramp at switch off (immediate off) Bit 1, 2: Set different regulation modes, dependent on the cable inductance: 0: fast: short cables, up to 1 meter. 1: moderate: cables from 1 to 30 meter. 2: fast: identical to 0 (should not be used) 3: slow: cables longer than 30 meter. Bit 3: Internal sense line connection to the output (MPOD only): 0: The sense input at the sense connector is used for regulation. 1: The output voltage is used for regulation. Any signals at the sense connector are ignored. Bit 4: Enable External Inhibit input. 0: The external inhibit input is ignored. 1: The external inhibit input must be connected to a voltage source to allow switch on. Bit 5: Disable Global Inhibit inputs. 0: The global inhibit/interlock inputs of the system is active. 1: The global inhibit/interlock inputs of the system is ignored. Bit 6: Automatic Power On. 0: After switching the main system switch ON, the output is not switched on automatically. A separate outputSwitch command is required. 1: After switching the main system switch ON, the output is switched on automatically. If 'Disable Global Inhibit' (bit 5) is set, the output will be switched on regardless of the global inhibit/interlock signals. Community required for write access: guru.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..127  

outputRegulationMode 2.1.19947.1.3.2.1.38
Definition of the regulation mode. Deprecated, use outputUserConfig for this function in the future! It is possible to set different regulation modes, dependent on the cable inductance. fast: short cables, up to 1 meter. moderate: cables from 1 to 30 meter. slow: cables longer than 30 meter. Community required for write access: guru.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER fast(0), moderate(1), slow(2)  

outputConfigMaxTemperature 2.1.19947.1.3.2.1.39
The maximum possible value of outputSupervisionMaxTemperature.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

outputResistance 2.1.19947.1.3.2.1.40
Item to specify an external resistor. For instance a wire resistor or an external resistor to protect the detectot which is supplied by a cascaded HV module.
Status: current Access: read-write
OBJECT-TYPE    
  Float  

outputTripTimeMinSenseVoltage 2.1.19947.1.3.2.1.41
Minimum time the outputSupervisionMinSenseVoltage threshold must be violated to activate the trip action [ms]. The trip action is defined in outputSupervisionBehavior or the new outputTripActionMinSenseVoltage.
Status: current Access: read-write
OBJECT-TYPE    
  OutputTripTime  

outputTripTimeMaxSenseVoltage 2.1.19947.1.3.2.1.42
Minimum time the outputSupervisionMaxSenseVoltage threshold must be violated to activate the trip action [ms]. The trip action is defined in outputSupervisionBehavior or the new outputTripActionMaxSenseVoltage.
Status: current Access: read-write
OBJECT-TYPE    
  OutputTripTime  

outputTripTimeMaxTerminalVoltage 2.1.19947.1.3.2.1.43
Minimum time the outputSupervisionMaxTerminalVoltage threshold must be violated to activate the trip action [ms]. The trip action is defined in outputSupervisionBehavior or the new outputTripActionMaxTerminalVoltage.
Status: current Access: read-write
OBJECT-TYPE    
  OutputTripTime  

outputTripTimeMaxTemperature 2.1.19947.1.3.2.1.44
Minimum time the outputSupervisionMaxTemperature threshold must be violated to activate the trip action [ms]. The trip action is defined in outputSupervisionBehavior or the new outputTripActionMaxTemperature.
Status: current Access: read-write
OBJECT-TYPE    
  OutputTripTime  

outputTripTimeMaxPower 2.1.19947.1.3.2.1.45
Minimum time the outputSupervisionMaxPower threshold must be violated to activate the trip action [ms]. The trip action is defined in outputSupervisionBehavior or the new outputTripActionMaxPower.
Status: current Access: read-write
OBJECT-TYPE    
  OutputTripTime  

outputTripTimeTimeout 2.1.19947.1.3.2.1.46
Maximum time the communication between module and controller can paused before activation the trip action [ms]. The trip action is defined in outputSupervisionBehavior or the new outputTripActionTimeout.
Status: current Access: read-write
OBJECT-TYPE    
  OutputTripTime  

outputTripActionMinSenseVoltage 2.1.19947.1.3.2.1.47
Trip action if outputSuperisionMinSenseVoltage threshold has been violated. The enumerated value is: WIENER LV devices 0 ignore the failure 1 switch off this channel 2 switch off all channels with the same group number 3 switch off the complete crate iseg HV devices 0 ignore the failure 1 switch off this channel by ramp down the voltage 2 switch off this channel by a emergencyOff 3 switch off the whole board of the HV module by emergencyOff. This is a direct access of bits 0..1 of outputSupervisionBehavior.
Status: current Access: read-write
OBJECT-TYPE    
  OutputTripAction  

outputTripActionMaxSenseVoltage 2.1.19947.1.3.2.1.48
Trip action if outputSuperisionMaxSenseVoltage threshold has been violated. The enumerated value is: WIENER LV devices 0 ignore the failure 1 switch off this channel 2 switch off all channels with the same group number 3 switch off the complete crate iseg HV devices 0 ignore the failure 1 switch off this channel by ramp down the voltage 2 switch off this channel by a emergencyOff 3 switch off the whole board of the HV module by emergencyOff. This is a direct access of bits 2..3 of outputSupervisionBehavior.
Status: current Access: read-write
OBJECT-TYPE    
  OutputTripAction  

outputTripActionMaxTerminalVoltage 2.1.19947.1.3.2.1.49
Trip action if outputSuperisionMaxTerminalVoltage threshold has been violated. The enumerated value is: WIENER LV devices 0 ignore the failure 1 switch off this channel 2 switch off all channels with the same group number 3 switch off the complete crate iseg HV devices 0 ignore the failure 1 switch off this channel by ramp down the voltage 2 switch off this channel by a emergencyOff 3 switch off the whole board of the HV module by emergencyOff. This is a direct access of bits 4..5 of outputSupervisionBehavior.
Status: current Access: read-write
OBJECT-TYPE    
  OutputTripAction  

outputTripActionMaxCurrent 2.1.19947.1.3.2.1.50
Trip action if outputSuperisionMaxCurrent threshold has been violated. The enumerated value is: WIENER LV devices 0 ignore the failure 1 switch off this channel 2 switch off all channels with the same group number 3 switch off the complete crate. iseg HV devices 0 ignore the failure 1 switch off this channel by ramp down the voltage 2 switch off this channel by a emergencyOff 3 switch off the whole board of the HV module by emergencyOff. This is a direct access of bits 6..7 of outputSupervisionBehavior.
Status: current Access: read-write
OBJECT-TYPE    
  OutputTripAction  

outputTripActionMaxTemperature 2.1.19947.1.3.2.1.51
Trip action if outputSuperisionMaxTemperature threshold has been violated. The enumerated value is: WIENER LV devices 0 ignore the failure 1 switch off this channel 2 switch off all channels with the same group number 3 switch off the complete crate iseg HV devices 0 ignore the failure 1 switch off this channel by ramp down the voltage 2 switch off this channel by a emergencyOff 3 switch off the whole board of the HV module by emergencyOff. This is a direct access of bits 8..9 of outputSupervisionBehavior.
Status: current Access: read-write
OBJECT-TYPE    
  OutputTripAction  

outputTripActionMaxPower 2.1.19947.1.3.2.1.52
Trip action if outputSuperisionMaxPower threshold has been violated. The enumerated value is: WIENER LV devices 0 ignore the failure 1 switch off this channel 2 switch off all channels with the same group number 3 switch off the complete crate iseg HV devices 0 ignore the failure 1 switch off this channel by ramp down the voltage 2 switch off this channel by a emergencyOff 3 switch off the whole board of the HV module by emergencyOff. This is a direct access of bits 10..11 of outputSupervisionBehavior.
Status: current Access: read-write
OBJECT-TYPE    
  OutputTripAction  

outputTripActionExternalInhibit 2.1.19947.1.3.2.1.53
Trip action if the external inhibit input has been activated. The enumerated value is: WIENER LV devices 0 ignore the failure 1 switch off this channel 2 switch off all channels with the same group number 3 switch off the complete crate iseg HV devices 0 ignore the failure 1 switch off this channel by ramp down the voltage 2 switch off this channel by a emergencyOff 3 switch off the whole board of the HV module by emergencyOff. This is a direct access of bits 12..13 of outputSupervisionBehavior.
Status: current Access: read-write
OBJECT-TYPE    
  OutputTripAction  

outputTripActionTimeout 2.1.19947.1.3.2.1.54
Trip action if the communication between module and controller has been paused longer than outputTripTimeTimeout. The enumerated value is: WIENER LV devices 0 ignore the failure 1 switch off this channel 2 switch off all channels with the same group number 3 switch off the complete crate iseg HV devices 0 ignore the failure 1 switch off this channel by ramp down the voltage 2 switch off this channel by a emergencyOff 3 switch off the whole board of the HV module by emergencyOff. This is a direct access of bits 14..15 of outputSupervisionBehavior.
Status: current Access: read-write
OBJECT-TYPE    
  OutputTripAction  

outputConfigDataS 2.1.19947.1.3.2.1.1024
Configuration Data raw access. This allows to read / write output channel specific user configuration data. This OID is intended for use by WIENER system software only and my not be accessed directly. snmpget: undefined behavior snmpset: OCTET STRING format for reading data (8 octets): offsetInOctets 4 octets / 32 bit numberOfOctets 4 octets / 32 bit OCTET STRING format used for writing data, or returned from the SNMP client after read/write (8+n octets): offsetInOctets 4 octets / 32 bit numberOfOctets 4 octets / 32 bit data numberOfOctets octets
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

outputConfigDataU 2.1.19947.1.3.2.1.1025
Configuration Data raw access. This allows to read / write output channel specific user configuration data. This OID is intended for use by WIENER system software only and my not be accessed directly. snmpget: undefined behavior snmpset: OCTET STRING format for reading data (8 octets): offsetInOctets 4 octets / 32 bit numberOfOctets 4 octets / 32 bit OCTET STRING format returned from the SNMP client, or used for writing data (8+n octets): offsetInOctets 4 octets / 32 bit numberOfOctets 4 octets / 32 bit data numberOfOctets octets
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

groupsEntry 2.1.19947.1.3.4.1
A table row
Status: current Access: not-accessible
OBJECT-TYPE    
  GroupsEntry  

groupsIndex 2.1.19947.1.3.4.1.1
A unique number for each power output group. Its value ranges between 1 and 1999. The special group 0 is predefined and gives access to all channels.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..1999  

groupsSwitch 2.1.19947.1.3.4.1.9
Read: This function is not defined with groups of output channels. Write: Switch the state of all channels of a group. If any channel is On, and the write value is Off, then all channels will switch off. If any channel is Off, and the write value is On, and if no other signals (mainInhibit, outputInhibit, outputEmergencyOff or outputFailureMaxCurrent) are active, then all channels will switch on. If the write value is resetEmergencyOff, then all channels will leave the state EmergencyOff. A write of clearEvents is necessary before the voltage can ramp up again. If the write value is setEmergencyOff, then all channels will have the state EmergencyOff, which means that the High Voltage will switch off without a ramp and reset of the outputVoltage to null volt. If the write value is disableKILL, then all channels will switch to disableKill (outputStatus outputDisableKill). If the write value is enableKILL, then all channels will switch to enableKill (outputStatus outputEnableKill). If the write value is clearEvents, then all failure messages of the outputStatus will be cleared (all channel events, all module events and the state outputEmergencyOff will be reset). For a detailed description of the different group numbers available look at the outputGroup OID above.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER undefined(-1), off(0), on(1), resetEmergencyOff(2), setEmergencyOff(3), disableKill(4), enableKill(5), disableAdjust(6), enableAdjust(7), clearEvents(10)  

moduleEntry 2.1.19947.1.3.6.1
A row in the table of HV/LV modules
Status: current Access: not-accessible
OBJECT-TYPE    
  ModuleEntry  

moduleIndex 2.1.19947.1.3.6.1.1
A unique number for each HV/LV module. Its value ranges between 1 and the total number of HV/LV modules. Note, index 1 corresponds to ma0.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER ma0(1), ma1(2), ma2(3), ma3(4), ma4(5), ma5(6), ma6(7), ma7(8), ma8(9), ma9(10)  

moduleDescription 2.1.19947.1.3.6.1.2
Vendor, FirmwareName, ChannelNumber, SerialNumber, FirmwareRelease Vendor WIENER or iseg FirmwareName: 'E16D0' EDS 16 channels per PCB, distributor module, range of Vmax from VO max to (VO max - 1kV) 'E16D1' EDS 16 channels per PCB, distributor module 'E08C0' EHS 8 channels per PCB, common GND module 'E08F0' EHS 8 channels per PCB, floating GND module 'E08F2' EHS 8 channels per PCB, floating GND module, 2 current measurement ranges 'E08C2' EHS 8 channels per PCB, common floating GND module, 2 current measurement ranges 'E08B0' EBS 8 bipolars channel per PCB, distributor module 'H101C0' HPS 1 channel HV high power supply ChannelNumber 1 to 64 SerialNumber 71xxxx FirmwareRelease x.xx
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..39)  

moduleAuxiliaryMeasurementVoltage 2.1.19947.1.3.6.1.3
The measured module auxiliary voltages.
Status: current Access: read-only
OBJECT-IDENTITY    

moduleAuxiliaryMeasurementVoltage0 2.1.19947.1.3.6.1.3.1
The measured module auxiliary voltage.
Status: current Access: read-only
OBJECT-TYPE    
  Float  

moduleAuxiliaryMeasurementVoltage1 2.1.19947.1.3.6.1.3.2
The measured module auxiliary voltage.
Status: current Access: read-only
OBJECT-TYPE    
  Float  

moduleHardwareLimitVoltage 2.1.19947.1.3.6.1.4
The module hardware voltage limit.
Status: current Access: read-only
OBJECT-TYPE    
  Float  

moduleHardwareLimitCurrent 2.1.19947.1.3.6.1.5
The module hardware current limit.
Status: current Access: read-only
OBJECT-TYPE    
  Float  

moduleRampSpeedVoltage 2.1.19947.1.3.6.1.6
The module voltage ramp speed (iseg HV modules have the same ramp speed value for all channels).
Status: current Access: read-write
OBJECT-TYPE    
  Float  

moduleRampSpeedCurrent 2.1.19947.1.3.6.1.7
The module current ramp speed (iseg HV modules have the same ramp speed value for all channels).
Status: current Access: read-write
OBJECT-TYPE    
  Float  

moduleStatus 2.1.19947.1.3.6.1.8
A bit string which shows the current module status. If a bit is set (1), the explanation is satisfied: moduleIsFineAdjustment (0), Module has reached state fine adjustment. moduleIsLiveInsertion (2), Module is in state live insertion. moduleNeedService (4), Hardware failure detected (consult iseg Spezialelektronik GmbH). moduleIsHardwareLimitVoltageGood (5), Hardware limit voltage in proper range, using for HV distributor modules with current mirror only. moduleIsInputError (6), Input error in connection with a module access. moduleIsNoSumError (8), All channels without any failure. moduleIsNoRamp (9), All channels stable, no is ramp active. moduleIsSafetyLoopGood (10), Safety loop is closed. moduleIsEventActive (11), Any event is active and mask is set. moduleIsGood (12), Module state is good. moduleIsSupplyGood (13), Power supply is good. moduleIsTemperatureGood (14), Module temperature is good. moduleIsKillEnable (15) Module state of kill enable.
Status: current Access: read-only
OBJECT-TYPE    
  BITS moduleIsFineAdjustment(0), moduleIsLiveInsertion(2), moduleIsHighVoltageOn(3), moduleNeedService(4), moduleHardwareLimitVoltageIsGood(5), moduleIsInputError(6), moduleIsNoSumError(8), moduleIsNoRamp(9), moduleSafetyLoopIsGood(10), moduleIsEventActive(11), moduleIsGood(12), moduleSupplyIsGood(13), moduleTemperatureIsGood(14), moduleIsKillEnable(15)  

moduleEventStatus 2.1.19947.1.3.6.1.9
A bit string which shows the current module status. If a bit is set (1), the explanation is satisfied: moduleEventPowerFail (0), Event power fail generated by the MPOD controller in order to ramp down all HV's (ramp speed=1000V/s) moduleEventLiveInsertion (2), Event live insertion to prepare a hot plug of a module moduleEventService (4), Module event: Hardware failure detected (consult iseg Spezialelektronik GmbH). moduleHardwareLimitVoltageNotGood (5), Module Event: Hardware voltage limit is not in proper range, using for HV distributor modules with current mirror only. moduleEventInputError (6), Module event: There was an input error in connection with a module access moduleEventSafetyLoopNotGood (10), Module event: Safety loop is open. moduleEventSupplyNotGood (13), Module event: At least one of the supplies is not good. moduleEventTemperatureNotGood (14), Module event: Temperature was above the permitted threshold (for EDS/EHS temperature above 55 degr.C)
Status: current Access: read-only
OBJECT-TYPE    
  BITS moduleEventPowerFail(0), moduleEventLiveInsertion(2), moduleEventService(4), moduleHardwareLimitVoltageNotGood(5), moduleEventInputError(6), moduleEventSafetyLoopNotGood(10), moduleEventSupplyNotGood(13), moduleEventTemperatureNotGood(14)  

moduleEventChannelStatus 2.1.19947.1.3.6.1.10
Bit field that reserves one bit for every channel. bit 0 HV channel 0 bit 1 HV channel 1 bit x HV channel x
Status: current Access: read-only
OBJECT-TYPE    
  BITS channel0(0), channel1(1), channel2(2), channel3(3), channel4(4), channel5(5), channel6(6), channel7(7), channel8(8), channel9(9), channel10(10), channel11(11), channel12(12), channel13(13), channel14(14), channel15(15), channel16(16), channel17(17), channel18(18), channel19(19), channel20(20), channel21(21), channel22(22), channel23(23), channel24(24), channel25(25), channel26(26), channel27(27), channel28(28), channel29(29), channel30(30), channel31(31), channel32(32), channel33(33), channel34(34), channel35(35), channel36(36), channel37(37), channel38(38), channel39(39), channel40(40), channel41(41), channel42(42), channel43(43), channel44(44), channel45(45), channel46(46), channel47(47)  

moduleDoClear 2.1.19947.1.3.6.1.11
All events of the module will be cleared.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER nothing(0), doClear(1)  

moduleAuxiliaryMeasurementTemperature 2.1.19947.1.3.6.1.12
The number of auxiliary temperature sensors in the module.
Status: current Access: read-write
OBJECT-IDENTITY    

moduleAuxiliaryMeasurementTemperature0 2.1.19947.1.3.6.1.12.1
The measured module temperature of sensor 1.
Status: current Access: read-only
OBJECT-TYPE    
  Float  

moduleAuxiliaryMeasurementTemperature1 2.1.19947.1.3.6.1.12.2
The measured module temperature of sensor 2.
Status: current Access: read-only
OBJECT-TYPE    
  Float  

moduleAuxiliaryMeasurementTemperature2 2.1.19947.1.3.6.1.12.3
The measured module temperature of sensor 3.
Status: current Access: read-only
OBJECT-TYPE    
  Float  

moduleAuxiliaryMeasurementTemperature3 2.1.19947.1.3.6.1.12.4
The measured module temperature of sensor 4.
Status: current Access: read-only
OBJECT-TYPE    
  Float  

moduleConfigDataS 2.1.19947.1.3.6.1.1024
Configuration Data raw access. This allows to read / write output channel specific system configuration data. This OID is intended for use by WIENER system software only and my not be accessed directly. snmpget: undefined behavior snmpset: OCTET STRING format for reading data (8 octets): offsetInOctets 4 octets / 32 bit numberOfOctets 4 octets / 32 bit OCTET STRING format returned from the SNMP client, or used for writing data (8+n octets): offsetInOctets 4 octets / 32 bit numberOfOctets 4 octets / 32 bit data numberOfOctets octets
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

moduleConfigDataU 2.1.19947.1.3.6.1.1025
Configuration Data raw access. This allows to read / write output channel specific user configuration data. This OID is intended for use by WIENER system software only and my not be accessed directly. snmpget: undefined behavior snmpset: OCTET STRING format for reading data (8 octets): offsetInOctets 4 octets / 32 bit numberOfOctets 4 octets / 32 bit OCTET STRING format returned from the SNMP client, or used for writing data (8+n octets): offsetInOctets 4 octets / 32 bit numberOfOctets 4 octets / 32 bit data numberOfOctets octets
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

sensorNumber 2.1.19947.1.4.1
The number of temperature sensors of the crate.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..8  

sensorTable 2.1.19947.1.4.2
A (conceptual table) of temperature sensor data.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SensorEntry

sensorEntry 2.1.19947.1.4.2.1
An entry (conceptual row) of the sensorTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  SensorEntry  

sensorIndex 2.1.19947.1.4.2.1.1
A unique number for each temperature sensor in the crate
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER temp1(1), temp2(2), temp3(3), temp4(4), temp5(5), temp6(6), temp7(7), temp8(8)  

sensorTemperature 2.1.19947.1.4.2.1.2
The measured temperature of the sensor. Unused temperature probes have the special value -128
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -128..127  

sensorWarningThreshold 2.1.19947.1.4.2.1.3
If the measured temperature of the sensor is higher than this value, the fan speed of the connected fan tray is increased. The value 127 has the special meaning: channel disabled.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..127  

sensorFailureThreshold 2.1.19947.1.4.2.1.4
If the measured temperature of the sensor is higher than this value, the power supply switches off. The value 127 has the special meaning: channel disabled.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..127  

sensorAlarmThreshold 2.1.19947.1.4.2.1.6
If the measured temperature of the sensor is much higher than this value, the fans rotate in full speed. The value 127 has the special meaning: channel disabled.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..127  

sensorName 2.1.19947.1.4.2.1.7
A textual string containing a short name of the sensor. If the crate is equipped with an alphanumeric display, this string is shown to identify a sensor channel.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..7)  

sensorID 2.1.19947.1.4.2.1.8
Shows the 1-Wire Id of the corresponding Sensor.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

sensorStatus 2.1.19947.1.4.2.1.9
A bit field packed into an integer which define the Status of the Sensors after failures. For each Status value, a two-bit field exists. Bits-Value 00 Temperature is ok 01 Temperature is over WarningThreshold 10 Temperature is over AlarmThreshold 11 Temperature is over FailureThreshold The position of the bit fields in the integer value are: Bit 0, 1: Sensor1 Bit 2, 3: Sensor2 Bit 4, 5: Sensor3 Bit 6, 7: Sensor4 Bit 8, 9: Sensor5 Bit 10, 11: Sensor6 Bit 12, 13: Sensor7 Bit 14, 15: Sensor8
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

snmp 2.1.19947.1.5.1
SNMP configuration.
Status: current Access: read-only
OBJECT-IDENTITY    

snmpCommunityTable 2.1.19947.1.5.1.1
The SNMP community string table for different views.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SnmpCommunityEntry

snmpCommunityEntry 2.1.19947.1.5.1.1.1
One table row.
Status: current Access: not-accessible
OBJECT-TYPE    
  SnmpCommunityEntry  

snmpAccessRight 2.1.19947.1.5.1.1.1.1
A unique number for each access right
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER public(1), private(2), admin(3), guru(4)  

snmpCommunityName 2.1.19947.1.5.1.1.1.2
The SNMP community names for different views. The rights of the different communities are: public no write access private can switch power on/off, generate system reset admin can change supervision levels guru can change output voltage & current (this may destroy hardware if done wrong!) Setting a community name to a zero-length string completly disables the access to this view. If there is no higher- privileged community, the community name can only changed by direct access to the crate (not via network)!
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..14)  

snmpPort 2.1.19947.1.5.1.2
The UDP port number of the SNMP protocol. A value of 0 disables all future SNMP communication!
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

httpPort 2.1.19947.1.5.1.3
The TCP port number of the HTTP (web) protocol. A value of 0 disables all HTTP access.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

firmwareUpdate 2.1.19947.1.5.1.10
Send a update String
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..30)  

ipDynamicAddress 2.1.19947.1.5.1.11
Shows the Ip which is currently used
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

ipStaticAddress 2.1.19947.1.5.1.12
Shows the Ip which is setted by user
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

macAddress 2.1.19947.1.5.1.13
Shows the MAC of the corresponding device
Status: current Access: read-write
OBJECT-TYPE    
  MacAddress  

can 2.1.19947.1.5.2
CAN-Bus tunnel via SNMP.
Status: current Access: read-write
OBJECT-IDENTITY    

canBitRate 2.1.19947.1.5.2.1
Control of the CAN-Bus. The value defines the bit rate of the CAN-bus interface. A write disconnects the CAN interface from the ISEG modules and connects it to the SNMP communication. Both the receive and transmit fifos are cleared and the CAN interface is initialized with the selected bit rate. The special bit rate 0 disables the tunnel and switches back to normal operation.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

canReceive 2.1.19947.1.5.2.2
Control of the CAN-Bus Receive FIFO. A read access returns the total number of CAN messages stored in the receive fifo and the oldest message. This message is removed from the fifo. The OCTET STRING data is formatted according to the CANviaSNMP structure.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(14)  

canTransmit 2.1.19947.1.5.2.3
Control of the CAN-Bus Transmit FIFO. A read access returns the total number of CAN messages stored in the transmit fifo and a NULL message. A write inserts the CAN message into the transmit fifo. This message will be transmitted via the CAN interface later. The total number of CAN messages stored in the transmit fifo and the recent message are returned. The OCTET STRING data is formatted according to the CANviaSNMP structure.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(14)  

canReceiveHv 2.1.19947.1.5.2.4
Control of the internal HV CAN-Bus on the backplane Receive FIFO. A read access returns the total number of CAN messages stored in the receive fifo and the oldest message. This message is removed from the fifo. The OCTET STRING data is formatted according to the CANviaSNMP structure.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(14)  

canTransmitHv 2.1.19947.1.5.2.5
Control of the internal HV CAN-Bus on the backplane. A write access with: CANID=0x600 DLC=4 DATAID=0x1001 CONTROL will switch the HV modules into a special state. CONTROL=0x0001 - enable SNMP CAN access, stop the refresh cycle for the data points of the name space CONTROL=0x0002 - disable SNMP CAN access, activate the refresh cycle for the data points of the name space A write access unequal to CANID=0x600 will be transmitted to the HV CAN on the backplane. Such a message will be transmitted immediately via the CAN interface. The OCTET STRING data is formatted according to the CANviaSNMP structure.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(14)  

canBitRateHv 2.1.19947.1.5.2.6
Control of the bit rate of the HV CAN-Bus. The value defines the bit rate of the CAN-bus interface. Possible Values are 125000 and 250000. Changing this value requires MPODC slave firmware 1.10 or above.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 125000..1000000  

psSerialNumber 2.1.19947.1.6.2
The serial number of the power supply.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

psOperatingTime 2.1.19947.1.6.3
The time in seconds for how long the power supply was switched on.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

psAuxiliaryNumber 2.1.19947.1.6.4
The number of auxiliary channels of the power supply.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..8  

psAuxiliaryTable 2.1.19947.1.6.5
A list of psAuxiliary entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PsAuxiliaryEntry

psDirectAccess 2.1.19947.1.6.1024
Direct data transfer to the UEP6000 power supply. A read access returns nothing, a write access returns the response of the power supply.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..14)  

psAuxiliaryEntry 2.1.19947.1.6.5.1
A table row
Status: current Access: not-accessible
OBJECT-TYPE    
  PsAuxiliaryEntry  

psAuxiliaryIndex 2.1.19947.1.6.5.1.1
A unique number for each power supply auxiliary channel. Its value ranges between 1 and total number of output channels. SMI index starts at 1, so index 1 corresponds to U0.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER u0(1), u1(2), u2(3), u3(4), u4(5), u5(6), u6(7), u7(8)  

psAuxiliaryMeasurementVoltage 2.1.19947.1.6.5.1.3
The measured power supply auxiliary output voltage.
Status: current Access: read-only
OBJECT-TYPE    
  Float  

psAuxiliaryMeasurementCurrent 2.1.19947.1.6.5.1.4
The measured power supply auxiliary output current.
Status: current Access: read-only
OBJECT-TYPE    
  Float  

fanSerialNumber 2.1.19947.1.7.2
The serial number of the fan tray.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..14)  

fanOperatingTime 2.1.19947.1.7.3
The time in seconds for how long the fan tray was switched on.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

fanAirTemperature 2.1.19947.1.7.4
The temperature of the fan tray inlet air.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

fanSwitchOffDelay 2.1.19947.1.7.5
The maximum time in seconds for which the fans will continue running after the power supply has been switched off. This feature is used to cool down the electronics after switching off.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..900  

fanNominalSpeed 2.1.19947.1.7.6
The nominal fan rotation speed (RPM, Revolutions Per Minute) Value 0 does switch off the fans (only allowed if at least one rack temperature sensor is present). Values 1..1199 are not allowed
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

fanNumberOfFans 2.1.19947.1.7.7
The number of installed fans
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..12  

fanSpeedTable 2.1.19947.1.7.8
A list of fanSpeedEntries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FanSpeedEntry

fanSpeedEntry 2.1.19947.1.7.8.1
A table row
Status: current Access: not-accessible
OBJECT-TYPE    
  FanSpeedEntry  

fanNumber 2.1.19947.1.7.8.1.1
A unique number for each fan.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..12  

fanSpeed 2.1.19947.1.7.8.1.2
The measured fan rotation speed (RPM, Revolutions Per Minute)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

fanMaxSpeed 2.1.19947.1.7.9
The highest allowed rotationspeed of fan.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

fanMinSpeed 2.1.19947.1.7.10
The lowest allowed Rotationspeed of fan.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

fanConfigMaxSpeed 2.1.19947.1.7.11
Hardwarelimits. Can only set by WIENER.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

fanConfigMinSpeed 2.1.19947.1.7.12
Hardwarelimits Can only set by WIENER.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

numberOfAnalogInputs 2.1.19947.1.9.1
The number of additional analog inputs of the crate.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..8  

analogInputTable 2.1.19947.1.9.2
A (conceptual table) of analog input data.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AnalogInputEntry

analogInputEntry 2.1.19947.1.9.2.1
An entry (conceptual row) of the analogInputTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  AnalogInputEntry  

analogInputIndex 2.1.19947.1.9.2.1.1
A unique number for each analog input of the crate
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..8  

analogMeasurementVoltage 2.1.19947.1.9.2.1.2
The measured voltage of the analog input.
Status: current Access: read-only
OBJECT-TYPE    
  Float  

analogMeasurementCurrent 2.1.19947.1.9.2.1.3
The measured current of the analog input.
Status: current Access: read-only
OBJECT-TYPE    
  Float  

digitalInput 2.1.19947.1.9.5
The value of the digital inputs.
Status: current Access: read-only
OBJECT-TYPE    
  BITS d0(0), d1(1), d2(2), d3(3), d4(4), d5(5), d6(6), d7(7)  

digitalOutput 2.1.19947.1.9.6
The value of the digital outputs.
Status: current Access: read-only
OBJECT-TYPE    
  BITS d0(0), d1(1), d2(2), d3(3), d4(4), d5(5), d6(6), d7(7)