V320-MIB

File: V320-MIB.mib (5283 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
Integer32 mib-2 Counter32
enterprises DisplayString NOTIFICATION-GROUP
OBJECT-GROUP

Defined Values

sub10OID 1.3.6.1.4.1.39003
Sub10 MIB
MODULE-IDENTITY    

terminal2 1.3.6.1.4.1.39003.2
OBJECT IDENTIFIER    

terminalLinkQuality 1.3.6.1.4.1.39003.2.1
A measure for quality of the microwave link. Green: good signal level to withstand heavy rain Yellow: sufficient signal level but no margin Red: insufficient signal level, link not available Unknown: no signal level data available
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER green(1), yellow(2), red(3), unknown(10)  

terminalReceivePower 1.3.6.1.4.1.39003.2.10
Receive signal level in dBm
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

terminalTemperature 1.3.6.1.4.1.39003.2.11
Temperature within the unit in degree Celsius
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

terminalLockDetector 1.3.6.1.4.1.39003.2.12
Lock detection signal level
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

terminalLinkQualityImproved 1.3.6.1.4.1.39003.2.13
Indicates a positive change of the received microwave signal and the quality change from red to green or from red to yellow.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER red2green(1), red2yellow(2), yellow2green(3)  

terminalLinkQualityReduced 1.3.6.1.4.1.39003.2.14
Indicates a negative change of the received microwave signal and the quality change from red to green or from red to yellow.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER green2yellow(1), green2red(2), yellow2red(3)  

terminalFirmwareversion 1.3.6.1.4.1.39003.2.21
Installed Firmware Version.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

terminalAuxVoltage 1.3.6.1.4.1.39003.2.25
Actual Voltage at Auxilary Port
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

terminalObjectGroup 1.3.6.1.4.1.39003.2.24
Terminal object group
Status: current Access: read-only
OBJECT-GROUP    

terminalTraps 1.3.6.1.4.1.39003.2.22
OBJECT IDENTIFIER    

terminalLinkQualityImprovedTrap 1.3.6.1.4.1.39003.2.22.1
A trap indicating that the microwave signal quality did increase.
Status: current Access: read-only
NOTIFICATION-TYPE    

terminalLinkQualityReducedTrap 1.3.6.1.4.1.39003.2.22.2
A trap indicating that the microwave signal quality did decrease.
Status: current Access: read-only
NOTIFICATION-TYPE    

terminalTemperatureHighTrap 1.3.6.1.4.1.39003.2.22.3
A trap indicating that the temperature within the unit is over or below 70 degree Celsius.
Status: current Access: read-only
NOTIFICATION-TYPE    

terminalTemperatureLowTrap 1.3.6.1.4.1.39003.2.22.4
A trap indicating that the temperature within the unit is over or below -40 degree Celsius.
Status: current Access: read-only
NOTIFICATION-TYPE    

terminalNotificationGroup 1.3.6.1.4.1.39003.2.23
Terminal notification group
Status: current Access: read-only
NOTIFICATION-GROUP