TN-Y1564-MIB

File: TN-Y1564-MIB.mib (23813 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMP-FRAMEWORK-MIB
TRANSITION-SMI INET-ADDRESS-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Integer32
DisplayString RowStatus TruthValue
SnmpAdminString tnProducts InetAddressType
InetAddress MacAddress

Defined Types

TnY1564ProfileEntry  
SEQUENCE    
  tnY1564ProfileName SnmpAdminString
  tnY1564ProfileDescription DisplayString
  tnY1564DuelEnded TruthValue
  tnY1564DstOamAware TruthValue
  tnY1564TrafficType INTEGER
  tnY1564MegLevel INTEGER
  tnY1564FrameSize INTEGER
  tnY1564UserFrameSize INTEGER
  tnY1564DwellTime INTEGER
  tnY1564SacFLR INTEGER
  tnY1564SacFTD INTEGER
  tnY1564SacFDV INTEGER
  tnY1564CirEnable TruthValue
  tnY1564CirStepDuration INTEGER
  tnY1564CirDmInterval INTEGER
  tnY1564CirStepCount INTEGER
  tnY1564EirEnable TruthValue
  tnY1564EirDuration INTEGER
  tnY1564EirDmInterval INTEGER
  tnY1564TrafficPolicingEnable TruthValue
  tnY1564TrafficPolicingDuration INTEGER
  tnY1564TrafficPolicingDmInterval INTEGER
  tnY1564PerfTestEnable TruthValue
  tnY1564PerfTestDuration INTEGER
  tnY1564PerfTestUserDuration INTEGER
  tnY1564PerfTestDmInterval INTEGER
  tnY1564ProfileStatus RowStatus

TnY1564ReportEntry  
SEQUENCE    
  tnY1564ReportName SnmpAdminString
  tnY1564ReportDscr DisplayString
  tnY1564ReportTime DisplayString
  tnY1564ReportTftpAddrType InetAddressType
  tnY1564ReportTftpAddr InetAddress
  tnY1564ReportTestStatus INTEGER
  tnY1564ReportAction INTEGER

Defined Values

tnY1564MIB 1.3.6.1.4.1.868.2.5.154
The MIB provides functionalities for system user management in TN modules.
MODULE-IDENTITY    

tnY1564MIBNotifications 1.3.6.1.4.1.868.2.5.154.1
OBJECT IDENTIFIER    

tnY1564MIBObjects 1.3.6.1.4.1.868.2.5.154.2
OBJECT IDENTIFIER    

tnY1564MIBConformance 1.3.6.1.4.1.868.2.5.154.3
OBJECT IDENTIFIER    

tnY1564CfgMgmt 1.3.6.1.4.1.868.2.5.154.2.1
OBJECT IDENTIFIER    

tnY1564ReportMgmt 1.3.6.1.4.1.868.2.5.154.2.2
OBJECT IDENTIFIER    

tnY1564ProfileTable 1.3.6.1.4.1.868.2.5.154.2.1.1
This table provides configuration of SOAM Maintenance Point.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TnY1564ProfileEntry

tnY1564ProfileEntry 1.3.6.1.4.1.868.2.5.154.2.1.1.1
A entry in the table represents a configuration for local SOAM.
Status: current Access: not-accessible
OBJECT-TYPE    
  TnY1564ProfileEntry  

tnY1564ProfileName 1.3.6.1.4.1.868.2.5.154.2.1.1.1.1
The name, ASCII range 33-126, of this table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SnmpAdminString  

tnY1564ProfileDescription 1.3.6.1.4.1.868.2.5.154.2.1.1.1.2
The description of this table.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..127)  

tnY1564DuelEnded 1.3.6.1.4.1.868.2.5.154.2.1.1.1.3
For future use.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

tnY1564DstOamAware 1.3.6.1.4.1.868.2.5.154.2.1.1.1.4
When set, switch transmits Y.1731 DMM frames for delay measurements and Y.1731 1DM frames when this is cleared. When Traffic Type is 'Y.1731 OAM', switch transmits Y.1731 LBM frames as background traffic when DST is configured as OAM-aware, and Y.1731 TST frames when not.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

tnY1564TrafficType 1.3.6.1.4.1.868.2.5.154.2.1.1.1.5
When set to 'Y.1731 OAM', this switch transmits Y.1731 OAM PDUs as background traffic, and DST is OAM-aware determines the PDU type. In the current version of the software, only one ECE can be tested at a time in this mode. When set to 'Simulated Customer', the software will generate a traffic-pattern per ECE that will hit the ECE, and use the ECE's counters to determine PASS/FAIL criteria.Besides supporting simultaneous test of multiple ECEs, 'Simulated Customer' has the advantage that the tester can see directly from the report if she has configured ECEs wrongly, since the report will show per-ECE counters and fail if an ECE under test is not hit as expected by the traffic pattern.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER y1731Oam(1), simCustomer(2)  

tnY1564MegLevel 1.3.6.1.4.1.868.2.5.154.2.1.1.1.6
The MEG level used in generated Y.1731 OAM frames (both LBM/TST and DMM/1DM).
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER one(1), two(2), three(3), four(4), five(5), six(6), seven(7)  

tnY1564FrameSize 1.3.6.1.4.1.868.2.5.154.2.1.1.1.7
Selects the frame size of the background traffic. The frame size does not include possible C-tag(s) added to match the ECE. Besides standard frame sizes there are two custom selections: MTU - The UNI's MTU will be used for the background traffic. User-defined - custom specification of a frame size of the background traffic. Valid range is 64 to 10236 bytes.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER bytes64(1), bytes128(2), bytes256(3), bytes512(4), bytes1024(5), bytes1280(6), bytes1518(7), mtu(8), userDefined(9)  

tnY1564UserFrameSize 1.3.6.1.4.1.868.2.5.154.2.1.1.1.8
User defined frame size of the background traffic. Valid range is 64 to 10236 bytes.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 64..10236  

tnY1564DwellTime 1.3.6.1.4.1.868.2.5.154.2.1.1.1.9
When a trial (a single step of a subtest) is executed, background traffic is transmitted for a certain period of time. When that period has elapsed, the Dwell Time determines how long to wait before reading hardware counters and status in order to assess the status of the trial. The required dwell time must be at least the worst-case roundtrip time, and therefore a.o. depends on the physical distance between the near and far ends. Valid range is from 100 to 10000 in steps of 100 milliseconds with a default of 500 milliseconds.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER  

tnY1564SacFLR 1.3.6.1.4.1.868.2.5.154.2.1.1.1.10
Defines the acceptable Frame Loss Ratio. The Acceptable FLR is measured in permille. Setting this to 1000 effectively disables this check.The number is used in all enabled subtests. Only delay measurement PDUs and green background traffic undergoes FLR check. If the number of looped green frames differs from the number of transmitted green frames by more than the 'Acceptable FLR', the test is considered failing, otherwise passing.If the EVC contains multiple ECEs that matches on the same VLAN ID (UNI ingress) and the EVC uses 'Tx Lookup' equal to 'VID-PCP', the NNI ingress rules count looped traffic per NNI outer tag's PCP, and therefore provide more detailed information about which ECE is failing, than if the EVC uses 'Tx Lookup' equal to 'VID', where all looped traffic arriving on NNI is counted on the same ECE. The disadvantage of the 'VID-PCP' method is that it uses more chip resources than does the 'VID' method. Valid range is from 0 to 1000 with a default of 0.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..1000  

tnY1564SacFTD 1.3.6.1.4.1.868.2.5.154.2.1.1.1.11
Defines the acceptable Frame Transfer Delay, measured in milliseconds. If the highest observed frame transfer delay exceeds this, the test fails. Valid range is from 0 to 10000 with a default of 0 milliseconds. A value of 0 disables this check.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..10000  

tnY1564SacFDV 1.3.6.1.4.1.868.2.5.154.2.1.1.1.12
Defines the acceptable Frame Delay Variation, measured in milliseconds. If the highest observed frame delay variation exceeds this, the test fails. Valid range is from 0 to 10000 with a default of 0 milliseconds. A value of 0 disables this check.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..10000  

tnY1564CirEnable 1.3.6.1.4.1.868.2.5.154.2.1.1.1.13
Set, to enable the CIR test.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

tnY1564CirStepDuration 1.3.6.1.4.1.868.2.5.154.2.1.1.1.14
Each step in the CIR configuration test applies background traffic for this number of seconds. Valid range is from 1 to 3600 with a default of 10 seconds.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 1..3600  

tnY1564CirDmInterval 1.3.6.1.4.1.868.2.5.154.2.1.1.1.15
A Y.1731 1DM or DMM frame (depending on type of test) is transmitted every so many milliseconds, in order to perform delay measurements (DM). The number should be selected so that at least three DM frames are transmitted during a trial in order to obtain delay variation results. After each trial the measured FTD and FDV is compared against the SAC's Acceptable FLR, FTD, and FDV. Valid range is from 100 to 10000 in steps of 100 milliseconds with a default of 500 milliseconds. A value of 0 effectively disables transmission of DM frames, which thereby indirectly disables the check against the SAC.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 100..10000  

tnY1564CirStepCount 1.3.6.1.4.1.868.2.5.154.2.1.1.1.16
The number of steps (trials) used to reach CIR. If, for example, Step Count is set to 4, four trials are executed. The first runs at 25% of this ECEs share of CIR, the second at 50%, then 75%, and finally 100%. A step count of 1 corresponds to executing Y.1564's A.1 test (Simple CIR Validation Test). A step count greater than 1 corresponds to executing Y.1564's A.2 test (Step Load CIR Test). Valid range is from 1 to 1000 with a default of 4 steps.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 1..1000  

tnY1564EirEnable 1.3.6.1.4.1.868.2.5.154.2.1.1.1.17
Set, to enable the EIR test.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

tnY1564EirDuration 1.3.6.1.4.1.868.2.5.154.2.1.1.1.18
The EIR configuration test is executed in one single trial, whose duration is configured with this parameter. Valid range is from 1 to 3600 with a default of 10 seconds.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 1..3600  

tnY1564EirDmInterval 1.3.6.1.4.1.868.2.5.154.2.1.1.1.19
A Y.1731 1DM or DMM frame (depending on type of test) is transmitted every so many milliseconds, in order to perform delay measurements (DM). The number should be selected so that at least three DM frames are transmitted during a trial in order to obtain delay variation results. After each trial the measured FTD and FDV is compared against the SAC's Acceptable FLR, FTD, and FDV. Valid range is from 100 to 10000 in steps of 100 milliseconds with a default of 500 milliseconds. A value of 0 effectively disables transmission of DM frames, which thereby indirectly disables the check against the SAC.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 100..10000  

tnY1564TrafficPolicingEnable 1.3.6.1.4.1.868.2.5.154.2.1.1.1.20
Set, to enable the Traffic Policing test.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

tnY1564TrafficPolicingDuration 1.3.6.1.4.1.868.2.5.154.2.1.1.1.21
The Traffic Policing test is executed in one single trial, whose duration is configured with this parameter. Valid range is from 1 to 3600 with a default of 10 seconds.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 1..3600  

tnY1564TrafficPolicingDmInterval 1.3.6.1.4.1.868.2.5.154.2.1.1.1.22
A Y.1731 1DM or DMM frame (depending on type of test) is transmitted every so many milliseconds, in order to perform delay measurements (DM). The number should be selected so that at least three DM frames are transmitted during a trial in order to obtain delay variation results. After each trial the measured FTD and FDV is compared against the SAC's Acceptable FLR, FTD, and FDV. Valid range is from 100 to 10000 in steps of 100 milliseconds with a default of 500 milliseconds. A value of 0 effectively disables transmission of DM frames, which thereby indirectly disables the check against the SAC.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 100..10000  

tnY1564PerfTestEnable 1.3.6.1.4.1.868.2.5.154.2.1.1.1.23
Set, to enable the Performance test.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

tnY1564PerfTestDuration 1.3.6.1.4.1.868.2.5.154.2.1.1.1.24
The performance test is executed in one single trial, whose duration is configured with this parameter. There are Y.1564-specified standard durations and a custom duration can be specified by selecting User-defined Duration option.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER mins15(1), hours2(2), hours24(3), userDefined(4)  

tnY1564PerfTestUserDuration 1.3.6.1.4.1.868.2.5.154.2.1.1.1.25
User defined duration. Valid range is from 1 to 86400 with a default of 900 seconds
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 1..86400  

tnY1564PerfTestDmInterval 1.3.6.1.4.1.868.2.5.154.2.1.1.1.26
A Y.1731 1DM or DMM frame (depending on type of test) is transmitted every so many milliseconds, in order to perform delay measurements (DM). The number should be selected so that at least three DM frames are transmitted during a trial in order to obtain delay variation results. After each trial the measured FTD and FDV is compared against the SAC's Acceptable FLR, FTD, and FDV. Valid range is from 100 to 10000 in steps of 100 milliseconds with a default of 500 milliseconds. A value of 0 effectively disables transmission of DM frames, which thereby indirectly disables the check against the SAC.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 100..10000  

tnY1564ProfileStatus 1.3.6.1.4.1.868.2.5.154.2.1.1.1.27
The status of the row. The writable columns in a row can not be changed if the row is active. All columns must have a valid value before a row can be activated.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

tnY1564ReportTable 1.3.6.1.4.1.868.2.5.154.2.2.1
This table provides configuration of SOAM Maintenance Point.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TnY1564ReportEntry

tnY1564ReportEntry 1.3.6.1.4.1.868.2.5.154.2.2.1.1
A entry in the table represents a configuration for local SOAM.
Status: current Access: not-accessible
OBJECT-TYPE    
  TnY1564ReportEntry  

tnY1564ReportName 1.3.6.1.4.1.868.2.5.154.2.2.1.1.1
The name, ASCII range 33-126, of this table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SnmpAdminString  

tnY1564ReportDscr 1.3.6.1.4.1.868.2.5.154.2.2.1.1.2
The description of this table.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..127)  

tnY1564ReportTime 1.3.6.1.4.1.868.2.5.154.2.2.1.1.3
The description of this table.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(26)  

tnY1564ReportTftpAddrType 1.3.6.1.4.1.868.2.5.154.2.2.1.1.4
The tftp server IP address type.
Status: current Access: read-write
OBJECT-TYPE    
  InetAddressType  

tnY1564ReportTftpAddr 1.3.6.1.4.1.868.2.5.154.2.2.1.1.5
The tftp server IP address.
Status: current Access: read-write
OBJECT-TYPE    
  InetAddress  

tnY1564ReportTestStatus 1.3.6.1.4.1.868.2.5.154.2.2.1.1.6
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER inactive(1), executing(2), cancelling(3), cancelled(4), passed(5), failed(6)  

tnY1564ReportAction 1.3.6.1.4.1.868.2.5.154.2.2.1.1.7
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noAction(1), cancelTest(2), saveReport(3), deleteReport(4)