TN-SYNCE-MIB

File: TN-SYNCE-MIB.mib (15221 bytes)

Imported modules

SNMPv2-TC ENTITY-MIB TRANSITION-SMI

Imported symbols

TruthValue MODULE-IDENTITY OBJECT-IDENTITY
entPhysicalIndex tnProducts

Defined Types

TnSyncEEntry  
SEQUENCE    
  tnSyncEStateMode INTEGER
  tnSyncEStateWTRTime INTEGER
  tnSyncEStateSSMHoldOver INTEGER
  tnSyncEStateSSMFreeRun INTEGER
  tnSyncEAlarmStateLOL TruthValue
  tnSyncEAlarmStateDHOLD TruthValue
  tnSyncESelState INTEGER
  tnSyncEClkSrc INTEGER

TnSyncEClkSourceEntry  
SEQUENCE    
  tnSyncEClkSourceIndex INTEGER
  tnSyncEConfPort INTEGER
  tnSyncEConfSSMOverwrite INTEGER
  tnSyncEConfHoldOff INTEGER
  tnSyncEConfANEG INTEGER
  tnSyncEPriority INTEGER
  tnSyncEClear TruthValue
  tnSyncEAlarmStateLOCS TruthValue
  tnSyncEAlarmStateSSM TruthValue
  tnSyncEAlarmStateWTR TruthValue
  tnSyncENominated TruthValue

TnSyncEPortEntry  
SEQUENCE    
  tnSyncEStatePortIndex INTEGER
  tnSyncEStateTxSSM INTEGER
  tnSyncEStateRxSSM INTEGER
  tnSyncEStateSSMMode INTEGER
  tnSyncESSMEnabled INTEGER

TnSyncEExtEntry  
SEQUENCE    
  tnSyncEExtInState INTEGER
  tnSyncEExtOutState INTEGER
  tnSyncEExtInFreq INTEGER
  tnSyncEExtOutFreq INTEGER
  tnSyncEExtImpedance INTEGER
  tnSyncEActualInFreq INTEGER
  tnSyncEActualOutFreq INTEGER

Defined Values

tnSynceMIB 1.3.6.1.4.1.868.2.5.122
The mib provides functionalities for managing SyncE.
MODULE-IDENTITY    

tnSynce 1.3.6.1.4.1.868.2.5.122.1
OBJECT IDENTIFIER    

tnSyncETable 1.3.6.1.4.1.868.2.5.122.1.1
Table to manage SyncE for each device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TnSyncEEntry

tnSyncEEntry 1.3.6.1.4.1.868.2.5.122.1.1.1
An entry containing SyncE for each device.
Status: current Access: not-accessible
OBJECT-TYPE    
  TnSyncEEntry  

tnSyncEStateMode 1.3.6.1.4.1.868.2.5.122.1.1.1.1
Clock source selection mode manual: Selector is manually set to the chosen clock source selected: Selector is manually set to the pt. selected clock source (not possible in unlocked mode) nonrevertive: Selector is automatically selecting the best clock source - non revertively revertive: Selector is automatically selecting the best clock source - revertively holdover: Selector is forced in holdover freerun: Selector is forced in free run
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER manual(1), selected(2), nonrevertive(3), revertive(4), holdover(5), freerun(6)  

tnSyncEStateWTRTime 1.3.6.1.4.1.868.2.5.122.1.1.1.2
WTR (Wait-to-Restore) time in minutes(0-12 min) '0' is disable
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

tnSyncEStateSSMHoldOver 1.3.6.1.4.1.868.2.5.122.1.1.1.3
Synchronization Status Messaging Hold Over. Hold Over is switching over to Local Reference Clock if primary and secondary nodes fail prc = Primary Reference Clock eec2 Ethernet Equipment Clock 1.544 kpbs eec1 Ethernet Equipment Clock 2.048 kpbs
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(0), prc(1), ssua(2), ssub(3), eec2(4), eec1(5), dnu(6), inv(7)  

tnSyncEStateSSMFreeRun 1.3.6.1.4.1.868.2.5.122.1.1.1.4
Synchronization Status Messaging Free Run
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(0), prc(1), ssua(2), ssub(3), eec2(4), eec1(5), dnu(6), inv(7)  

tnSyncEAlarmStateLOL 1.3.6.1.4.1.868.2.5.122.1.1.1.5
Alarm State Loss of Lock (LOL)
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tnSyncEAlarmStateDHOLD 1.3.6.1.4.1.868.2.5.122.1.1.1.6
Alarm State Digital Hold (DHOLD)
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tnSyncESelState 1.3.6.1.4.1.868.2.5.122.1.1.1.7
Clock Selection State Note: prelock2, prelock and lossoflock are not available on all products
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER lockedto(1), holdover(2), freerun(3), prelock2(4), prelock(5), lossoflock(6)  

tnSyncEClkSrc 1.3.6.1.4.1.868.2.5.122.1.1.1.8
Clock Source
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

tnSyncEClkSourceTable 1.3.6.1.4.1.868.2.5.122.1.2
Table of SyncE ClkSource
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TnSyncEClkSourceEntry

tnSyncEClkSourceEntry 1.3.6.1.4.1.868.2.5.122.1.2.1
An entry in the table,tnSyncEClkSourceTable
Status: current Access: not-accessible
OBJECT-TYPE    
  TnSyncEClkSourceEntry  

tnSyncEClkSourceIndex 1.3.6.1.4.1.868.2.5.122.1.2.1.1
Index of SyncE ClkSource table. 1-SYNCE_NOMINATED_MAX
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

tnSyncEConfPort 1.3.6.1.4.1.868.2.5.122.1.2.1.2
SyncE Configuration Port. 0-MAX_PORT. a port value of 0 means not nominated
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

tnSyncEConfSSMOverwrite 1.3.6.1.4.1.868.2.5.122.1.2.1.3
Clock source SSM overwrite
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(0), prc(1), ssua(2), ssub(3), eec2(4), eec1(5), dnu(6)  

tnSyncEConfHoldOff 1.3.6.1.4.1.868.2.5.122.1.2.1.4
The hold off timer value in 100 ms. Valid values are: 0 for disable. The range 3-18. The value 100 for test
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

tnSyncEConfANEG 1.3.6.1.4.1.868.2.5.122.1.2.1.5
Auto Negotiate : 1000BaseT ANEG mode slave: Activate prefer slave negotiation master: Activate prefer master negotiation forced: Activate forced slave negotiation.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(0), slave(1), master(2), forced(3)  

tnSyncEPriority 1.3.6.1.4.1.868.2.5.122.1.2.1.6
Clock source priority setting. (SYNCE_PRIORITY_MAX = CLOCK_INPUT_MAX = 2 i.e. 0,1)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

tnSyncEClear 1.3.6.1.4.1.868.2.5.122.1.2.1.7
SyncE Clear.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

tnSyncEAlarmStateLOCS 1.3.6.1.4.1.868.2.5.122.1.2.1.8
SyncE Alarm State LOCS.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tnSyncEAlarmStateSSM 1.3.6.1.4.1.868.2.5.122.1.2.1.9
SyncE Alarm State SSM.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tnSyncEAlarmStateWTR 1.3.6.1.4.1.868.2.5.122.1.2.1.10
SyncE Alarm State WRT.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

tnSyncENominated 1.3.6.1.4.1.868.2.5.122.1.2.1.11
SyncE Nominated.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

tnSyncEPortTable 1.3.6.1.4.1.868.2.5.122.1.3
Table of SyncEPort.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TnSyncEPortEntry

tnSyncEPortEntry 1.3.6.1.4.1.868.2.5.122.1.3.1
An entry containing tnSynce.
Status: current Access: not-accessible
OBJECT-TYPE    
  TnSyncEPortEntry  

tnSyncEStatePortIndex 1.3.6.1.4.1.868.2.5.122.1.3.1.1
SyncE Port index, 0-SYNCE_PORT_COUNT.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

tnSyncEStateTxSSM 1.3.6.1.4.1.868.2.5.122.1.3.1.2
SyncE Transmit SSM State.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), prc(1), ssua(2), ssub(3), dnu(4), eec2(5), eec1(6), inv(7), fail(8), link(9)  

tnSyncEStateRxSSM 1.3.6.1.4.1.868.2.5.122.1.3.1.3
SyncE Receive SSM State.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), prc(1), ssua(2), ssub(3), dnu(4), eec2(5), eec1(6), inv(7), fail(8), link(9)  

tnSyncEStateSSMMode 1.3.6.1.4.1.868.2.5.122.1.3.1.4
SyncE SSM Mode.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER master(1), slave(2)  

tnSyncESSMEnabled 1.3.6.1.4.1.868.2.5.122.1.3.1.5
SyncE SSM Enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

tnSyncEExtTable 1.3.6.1.4.1.868.2.5.122.1.4
Table of SyncE External I/O
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TnSyncEExtEntry

tnSyncEExtEntry 1.3.6.1.4.1.868.2.5.122.1.4.1
An entry in the table,tnSyncEExtTable
Status: current Access: not-accessible
OBJECT-TYPE    
  TnSyncEExtEntry  

tnSyncEExtInState 1.3.6.1.4.1.868.2.5.122.1.4.1.1
External I/O in direction state.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

tnSyncEExtOutState 1.3.6.1.4.1.868.2.5.122.1.4.1.2
External I/O out direction state.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

tnSyncEExtInFreq 1.3.6.1.4.1.868.2.5.122.1.4.1.3
External I/O in direction frequency 8k-25Mhz table of values.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER f8kHz(1), f64kHz(2), f1544kHz(3), f2048kHz(4), f10000kHz(5), f19440kHz(6), f25Mhz(7)  

tnSyncEExtOutFreq 1.3.6.1.4.1.868.2.5.122.1.4.1.4
External I/O out direction frequency 8k-25Mhz table of values
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER f8kHz(1), f64kHz(2), f1544kHz(3), f2048kHz(4), f10000kHz(5), f19440kHz(6), f25Mhz(7)  

tnSyncEExtImpedance 1.3.6.1.4.1.868.2.5.122.1.4.1.5
External I/O Impedance.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER imp50(1), imp75(2), hi-Z(3)  

tnSyncEActualInFreq 1.3.6.1.4.1.868.2.5.122.1.4.1.6
The actual input frequency in Hz.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

tnSyncEActualOutFreq 1.3.6.1.4.1.868.2.5.122.1.4.1.7
The actual output frequency in Hz. If output state is disabled set to 0
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER