TN-SYNCE-MIB
File:
TN-SYNCE-MIB.mib (15221 bytes)
Imported modules
Imported symbols
Defined Types
TnSyncEEntry |
|
SEQUENCE |
|
|
|
|
tnSyncEStateMode |
INTEGER |
|
|
tnSyncEStateWTRTime |
INTEGER |
|
|
tnSyncEStateSSMHoldOver |
INTEGER |
|
|
tnSyncEStateSSMFreeRun |
INTEGER |
|
|
tnSyncEAlarmStateLOL |
TruthValue |
|
|
tnSyncEAlarmStateDHOLD |
TruthValue |
|
|
tnSyncESelState |
INTEGER |
|
|
tnSyncEClkSrc |
INTEGER |
|
TnSyncEClkSourceEntry |
|
SEQUENCE |
|
|
|
|
tnSyncEClkSourceIndex |
INTEGER |
|
|
tnSyncEConfPort |
INTEGER |
|
|
tnSyncEConfSSMOverwrite |
INTEGER |
|
|
tnSyncEConfHoldOff |
INTEGER |
|
|
tnSyncEConfANEG |
INTEGER |
|
|
tnSyncEPriority |
INTEGER |
|
|
tnSyncEClear |
TruthValue |
|
|
tnSyncEAlarmStateLOCS |
TruthValue |
|
|
tnSyncEAlarmStateSSM |
TruthValue |
|
|
tnSyncEAlarmStateWTR |
TruthValue |
|
|
tnSyncENominated |
TruthValue |
|
TnSyncEPortEntry |
|
SEQUENCE |
|
|
|
|
tnSyncEStatePortIndex |
INTEGER |
|
|
tnSyncEStateTxSSM |
INTEGER |
|
|
tnSyncEStateRxSSM |
INTEGER |
|
|
tnSyncEStateSSMMode |
INTEGER |
|
|
tnSyncESSMEnabled |
INTEGER |
|
TnSyncEExtEntry |
|
SEQUENCE |
|
|
|
|
tnSyncEExtInState |
INTEGER |
|
|
tnSyncEExtOutState |
INTEGER |
|
|
tnSyncEExtInFreq |
INTEGER |
|
|
tnSyncEExtOutFreq |
INTEGER |
|
|
tnSyncEExtImpedance |
INTEGER |
|
|
tnSyncEActualInFreq |
INTEGER |
|
|
tnSyncEActualOutFreq |
INTEGER |
|
Defined Values
tnSynceMIB |
1.3.6.1.4.1.868.2.5.122 |
The mib provides functionalities for managing SyncE. |
MODULE-IDENTITY |
|
|
|
tnSynce |
1.3.6.1.4.1.868.2.5.122.1 |
OBJECT IDENTIFIER |
|
|
|
tnSyncETable |
1.3.6.1.4.1.868.2.5.122.1.1 |
Table to manage SyncE for each device. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
TnSyncEEntry |
|
tnSyncEEntry |
1.3.6.1.4.1.868.2.5.122.1.1.1 |
An entry containing SyncE for each device. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
TnSyncEEntry |
|
|
tnSyncEStateMode |
1.3.6.1.4.1.868.2.5.122.1.1.1.1 |
Clock source selection mode
manual: Selector is manually set to the chosen clock source
selected: Selector is manually set to the pt. selected clock source (not possible in unlocked mode)
nonrevertive: Selector is automatically selecting the best clock source - non revertively
revertive: Selector is automatically selecting the best clock source - revertively
holdover: Selector is forced in holdover
freerun: Selector is forced in free run |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
manual(1), selected(2), nonrevertive(3), revertive(4), holdover(5), freerun(6) |
|
tnSyncEStateWTRTime |
1.3.6.1.4.1.868.2.5.122.1.1.1.2 |
WTR (Wait-to-Restore) time in minutes(0-12 min) '0' is disable |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
tnSyncEStateSSMHoldOver |
1.3.6.1.4.1.868.2.5.122.1.1.1.3 |
Synchronization Status Messaging Hold Over.
Hold Over is switching over to Local Reference Clock if primary and secondary nodes fail
prc = Primary Reference Clock
eec2 Ethernet Equipment Clock 1.544 kpbs
eec1 Ethernet Equipment Clock 2.048 kpbs |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
none(0), prc(1), ssua(2), ssub(3), eec2(4), eec1(5), dnu(6), inv(7) |
|
tnSyncEStateSSMFreeRun |
1.3.6.1.4.1.868.2.5.122.1.1.1.4 |
Synchronization Status Messaging Free Run |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
none(0), prc(1), ssua(2), ssub(3), eec2(4), eec1(5), dnu(6), inv(7) |
|
tnSyncESelState |
1.3.6.1.4.1.868.2.5.122.1.1.1.7 |
Clock Selection State
Note: prelock2, prelock and lossoflock
are not available on all products |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
lockedto(1), holdover(2), freerun(3), prelock2(4), prelock(5), lossoflock(6) |
|
tnSyncEClkSrc |
1.3.6.1.4.1.868.2.5.122.1.1.1.8 |
Clock Source |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
tnSyncEClkSourceEntry |
1.3.6.1.4.1.868.2.5.122.1.2.1 |
An entry in the table,tnSyncEClkSourceTable |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
TnSyncEClkSourceEntry |
|
|
tnSyncEClkSourceIndex |
1.3.6.1.4.1.868.2.5.122.1.2.1.1 |
Index of SyncE ClkSource table. 1-SYNCE_NOMINATED_MAX |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
tnSyncEConfPort |
1.3.6.1.4.1.868.2.5.122.1.2.1.2 |
SyncE Configuration Port. 0-MAX_PORT.
a port value of 0 means not nominated |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
tnSyncEConfSSMOverwrite |
1.3.6.1.4.1.868.2.5.122.1.2.1.3 |
Clock source SSM overwrite |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
none(0), prc(1), ssua(2), ssub(3), eec2(4), eec1(5), dnu(6) |
|
tnSyncEConfHoldOff |
1.3.6.1.4.1.868.2.5.122.1.2.1.4 |
The hold off timer value in 100 ms.
Valid values are: 0 for disable. The range 3-18. The value 100 for test |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
tnSyncEConfANEG |
1.3.6.1.4.1.868.2.5.122.1.2.1.5 |
Auto Negotiate : 1000BaseT ANEG mode
slave: Activate prefer slave negotiation
master: Activate prefer master negotiation
forced: Activate forced slave negotiation. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
none(0), slave(1), master(2), forced(3) |
|
tnSyncEPriority |
1.3.6.1.4.1.868.2.5.122.1.2.1.6 |
Clock source priority setting. (SYNCE_PRIORITY_MAX = CLOCK_INPUT_MAX = 2 i.e. 0,1) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
tnSyncEClear |
1.3.6.1.4.1.868.2.5.122.1.2.1.7 |
SyncE Clear. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
tnSyncEPortEntry |
1.3.6.1.4.1.868.2.5.122.1.3.1 |
An entry containing tnSynce. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
TnSyncEPortEntry |
|
|
tnSyncEStatePortIndex |
1.3.6.1.4.1.868.2.5.122.1.3.1.1 |
SyncE Port index, 0-SYNCE_PORT_COUNT. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
tnSyncEStateTxSSM |
1.3.6.1.4.1.868.2.5.122.1.3.1.2 |
SyncE Transmit SSM State. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
none(0), prc(1), ssua(2), ssub(3), dnu(4), eec2(5), eec1(6), inv(7), fail(8), link(9) |
|
tnSyncEStateRxSSM |
1.3.6.1.4.1.868.2.5.122.1.3.1.3 |
SyncE Receive SSM State. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
none(0), prc(1), ssua(2), ssub(3), dnu(4), eec2(5), eec1(6), inv(7), fail(8), link(9) |
|
tnSyncEStateSSMMode |
1.3.6.1.4.1.868.2.5.122.1.3.1.4 |
SyncE SSM Mode. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
master(1), slave(2) |
|
tnSyncESSMEnabled |
1.3.6.1.4.1.868.2.5.122.1.3.1.5 |
SyncE SSM Enabled. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
enable(1), disable(2) |
|
tnSyncEExtTable |
1.3.6.1.4.1.868.2.5.122.1.4 |
Table of SyncE External I/O |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
TnSyncEExtEntry |
|
tnSyncEExtEntry |
1.3.6.1.4.1.868.2.5.122.1.4.1 |
An entry in the table,tnSyncEExtTable |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
TnSyncEExtEntry |
|
|
tnSyncEExtInState |
1.3.6.1.4.1.868.2.5.122.1.4.1.1 |
External I/O in direction state. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
enable(1), disable(2) |
|
tnSyncEExtOutState |
1.3.6.1.4.1.868.2.5.122.1.4.1.2 |
External I/O out direction state. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
enable(1), disable(2) |
|
tnSyncEExtInFreq |
1.3.6.1.4.1.868.2.5.122.1.4.1.3 |
External I/O in direction frequency
8k-25Mhz table of values. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
f8kHz(1), f64kHz(2), f1544kHz(3), f2048kHz(4), f10000kHz(5), f19440kHz(6), f25Mhz(7) |
|
tnSyncEExtOutFreq |
1.3.6.1.4.1.868.2.5.122.1.4.1.4 |
External I/O out direction frequency
8k-25Mhz table of values |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
f8kHz(1), f64kHz(2), f1544kHz(3), f2048kHz(4), f10000kHz(5), f19440kHz(6), f25Mhz(7) |
|
tnSyncEExtImpedance |
1.3.6.1.4.1.868.2.5.122.1.4.1.5 |
External I/O Impedance. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
imp50(1), imp75(2), hi-Z(3) |
|
tnSyncEActualInFreq |
1.3.6.1.4.1.868.2.5.122.1.4.1.6 |
The actual input frequency in Hz. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
tnSyncEActualOutFreq |
1.3.6.1.4.1.868.2.5.122.1.4.1.7 |
The actual output frequency in Hz. If output state is disabled set to 0 |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|