TN-POWER-SUPPLY-MIB
File:
TN-POWER-SUPPLY-MIB.mib (4574 bytes)
Imported modules
Imported symbols
Defined Types
TnPowerSupplyPowerType |
|
A kind of variable-type definition indicates the means of power-supply,
AC or DC. |
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
ac(1), dc(2) |
|
TnPowerSupplyEntry |
|
SEQUENCE |
|
|
|
|
tnPowerSupplyIndex |
Unsigned32 |
|
|
tnPowerSupplyPresent |
TruthValue |
|
|
tnPowerSupplyPowerType |
TnPowerSupplyPowerType |
|
|
tnPowerSupplyPowered |
TruthValue |
|
|
tnPowerSupplyFanRPM |
Unsigned32 |
|
|
tnPowerSupplyTemperature |
INTEGER |
|
Defined Values
tnPowerSupply |
1.3.6.1.4.1.868.2.5.20 |
This mib is related to the manamgement of power-supply. |
MODULE-IDENTITY |
|
|
|
tnPowerSupplyEnvMonFailureNotif |
1.3.6.1.4.1.868.2.5.20.1.1 |
A tnPowerSupplyEnvMonFailureNotif will be sent when the power-supply
is not functioning properly. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
tnPowerSupplyEnvMonTemperatureNotif |
1.3.6.1.4.1.868.2.5.20.1.2 |
A tnPowerSupplyEnvMonTemperatureNotif will be sent when the
temperature of the power-supply is out of controlled range. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
tnPowerSupplyEntry |
1.3.6.1.4.1.868.2.5.20.2.1.1 |
Indicates the entry of power-supply table. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
TnPowerSupplyEntry |
|
|
tnPowerSupplyIndex |
1.3.6.1.4.1.868.2.5.20.2.1.1.1 |
Indicates the index of table entry. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
tnPowerSupplyPresent |
1.3.6.1.4.1.868.2.5.20.2.1.1.2 |
Indicates the current choice of power-supply. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
tnPowerSupplyPowered |
1.3.6.1.4.1.868.2.5.20.2.1.1.4 |
Indicates power-supply is on or off. In this case, true represents powered-on,
and otherwise, powered-off. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
tnPowerSupplyTemperature |
1.3.6.1.4.1.868.2.5.20.2.1.1.6 |
Indicates the temperature of the power-supply. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|