TN-EVC-MIB

File: TN-EVC-MIB.mib (86725 bytes)

Imported modules

SNMPv2-SMI INET-ADDRESS-MIB SNMPv2-CONF
ENTITY-MIB SNMPv2-TC SNMP-FRAMEWORK-MIB
Q-BRIDGE-MIB IF-MIB TRANSITION-SMI

Imported symbols

MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
Unsigned32 Counter64 InetAddress
MODULE-COMPLIANCE OBJECT-GROUP NOTIFICATION-GROUP
entPhysicalIndex TEXTUAL-CONVENTION TruthValue
RowStatus MacAddress StorageType
SnmpAdminString VlanId VlanIdOrAny
VlanIdOrNone VlanIdOrAnyOrNone PortList
ifIndex InterfaceIndexOrZero tnProducts

Defined Types

TnEvcPortEntry  
SEQUENCE    
  tnEvcPortDEIMode INTEGER
  tnEvcPortTagMode INTEGER
  tnEvcPortAddressMode INTEGER

TnEvcEntry  
SEQUENCE    
  tnEvcIndex INTEGER
  tnEvcNNIPortlist PortList
  tnEvcVid VlanIdOrAny
  tnEvcIVid VlanIdOrAny
  tnEvcLearning INTEGER
  tnEvcInnerTagType INTEGER
  tnEvcInnerVidMode INTEGER
  tnEvcInnerVid VlanIdOrAnyOrNone
  tnEvcInnerPCPDEIPreservation INTEGER
  tnEvcInnerPCP INTEGER
  tnEvcInnerDEI INTEGER
  tnEvcOuterVid VlanIdOrAnyOrNone
  tnEvcStatus RowStatus
  tnEvcPolicerID INTEGER
  tnEvcName OCTET STRING

TnEvcEceEntry  
SEQUENCE    
  tnEvcEceId INTEGER
  tnEvcEceNextEceId INTEGER
  tnEvcEceUNIPortlist PortList
  tnEvcEceTagType INTEGER
  tnEvcEceTagVIDFilterType INTEGER
  tnEvcEceTagVIDFilterVal VlanIdOrAnyOrNone
  tnEvcEceTagVIDFilterStart VlanIdOrAnyOrNone
  tnEvcEceTagVIDFilterEnd VlanIdOrAnyOrNone
  tnEvcEceTagPCP BITS
  tnEvcEceTagDEI INTEGER
  tnEvcEceTagFrameType INTEGER
  tnEvcEceProtoType INTEGER
  tnEvcEceProtoVal INTEGER
  tnEvcEceDscpFilterType INTEGER
  tnEvcEceDscpFilterVal INTEGER
  tnEvcEceDscpRangeStart INTEGER
  tnEvcEceDscpRangeEnd INTEGER
  tnEvcEceSrcPortFilterType INTEGER
  tnEvcEceSrcPortFilterNo INTEGER
  tnEvcEceSrcPortRangeStart INTEGER
  tnEvcEceSrcPortRangeEnd INTEGER
  tnEvcEceDstPortFilterType INTEGER
  tnEvcEceDstPortFilterNo INTEGER
  tnEvcEceDstPortRangeStart INTEGER
  tnEvcEceDstPortRangeEnd INTEGER
  tnEvcEceIpv4DipSipFilter INTEGER
  tnEvcEceIpv4DipSipAddr InetAddress
  tnEvcEceIpv4DipSipMask InetAddress
  tnEvcEceIpv4Fragment INTEGER
  tnEvcEceIpv6DipSipFilter INTEGER
  tnEvcEceIpv6DipSipAddr Unsigned32
  tnEvcEceIpv6DipSipMask Unsigned32
  tnEvcEceOuterMode INTEGER
  tnEvcEceOuterPCPDEIPreserve INTEGER
  tnEvcEceOuterPCP INTEGER
  tnEvcEceOuterDEI INTEGER
  tnEvcEceActDirection INTEGER
  tnEvcEceActEvcidFilterType INTEGER
  tnEvcEceActEvcidVal INTEGER
  tnEvcEceActTagPopCount INTEGER
  tnEvcEceActPolicyId INTEGER
  tnEvcEceActClass INTEGER
  tnEvcEceDMacSMacFilterType INTEGER
  tnEvcEceDMacSMacVal MacAddress
  tnEvcEceDMacType INTEGER
  tnEvcEceConflict INTEGER
  tnEvcEceStatus RowStatus

TnEvcBandwidthProfilesEntry  
SEQUENCE    
  tnEvcBandwidthProfilesIndex INTEGER
  tnEvcBandwidthProfilesPolicerMode INTEGER
  tnEvcBandwidthProfilesCIR INTEGER
  tnEvcBandwidthProfilesCBS INTEGER
  tnEvcBandwidthProfilesEIR INTEGER
  tnEvcBandwidthProfilesEBS INTEGER
  tnEvcBandwidthProfilesState INTEGER

TnEvcExtEceEntry  
SEQUENCE    
  tnEvcEceInnerTagType INTEGER
  tnEvcEceInnerTagVIDFilterType INTEGER
  tnEvcEceInnerTagVIDFilterVal VlanIdOrNone
  tnEvcEceInnerTagVIDFilterStart VlanIdOrNone
  tnEvcEceInnerTagVIDFilterEnd VlanIdOrNone
  tnEvcEceInnerTagPCP BITS
  tnEvcEceInnerTagDEI INTEGER
  tnEvcEcePolicer INTEGER
  tnEvcEceOuterVid VlanIdOrNone
  tnEvcEceNNIInnerTagType INTEGER
  tnEvcEceInnerVid VlanIdOrNone
  tnEvcEceInnerPCPDEIPreserve INTEGER
  tnEvcEceInnerPCP INTEGER
  tnEvcEceInnerDEI INTEGER
  tnEvcEceDMacVal MacAddress
  tnEvcEceOuterPCPMode INTEGER
  tnEvcEceOuterDEIMode INTEGER
  tnEvcEceActRuleType INTEGER
  tnEvcEceActTxLookupType INTEGER
  tnEvcEceActDropPrecType INTEGER
  tnEvcEceInnerPcpMode INTEGER
  tnEvcEceIInnerDeiMode INTEGER
  tnEvcEceIpv4DipFilter INTEGER
  tnEvcEceIpv4DipAddr InetAddress
  tnEvcEceIpv4DipMask InetAddress
  tnEvcEceIpv6DipFilter INTEGER
  tnEvcEceIpv6DipAddr Unsigned32
  tnEvcEceIpv6DipMask Unsigned32
  tnEvcEceLookup INTEGER
  tnEvcEceEtypeFilter INTEGER
  tnEvcEceEtypeValue Unsigned32
  tnEvcEceEtypeDataFilter INTEGER
  tnEvcEceEtypeData Unsigned32
  tnEvcEceEtypeDataMask Unsigned32
  tnEvcEceLlcDSAPFilter INTEGER
  tnEvcEceLlcDSAPValue Unsigned32
  tnEvcEceLlcSSAPFilter INTEGER
  tnEvcEceLlcSSAPValue Unsigned32
  tnEvcEceLlcCtrlFilter INTEGER
  tnEvcEceLlcCtrlValue Unsigned32
  tnEvcEceLlcDataFilter INTEGER
  tnEvcEceLlcDataValue Unsigned32
  tnEvcEceLlcDataMask Unsigned32
  tnEvcEceSnapOuiFilter INTEGER
  tnEvcEceSnapOuiValue Unsigned32
  tnEvcEceSnapPidFilter INTEGER
  tnEvcEceSnapPidValue Unsigned32
  tnEvcEceL2cpProtoType INTEGER

TnEvcStatEntry  
SEQUENCE    
  tnEvcStatClass INTEGER
  tnEvcStatGreenFrameRx Counter64
  tnEvcStatGreenFrameTx Counter64
  tnEvcStatYellowFrameRx Counter64
  tnEvcStatYellowFrameTx Counter64
  tnEvcStatRedFrameRx Counter64
  tnEvcStatDiscardGreenFrame Counter64
  tnEvcStatDiscardYellowFrame Counter64
  tnEvcStatClear TruthValue

TnEvcExtStatEntry  
SEQUENCE    
  tnEvcExtStatType INTEGER
  tnEvcExtStatIndex INTEGER
  tnEvcExtStatPort INTEGER
  tnEvcExtStatGreenFrameRx Counter64
  tnEvcExtStatGreenFrameTx Counter64
  tnEvcExtStatGreenBytesRx Counter64
  tnEvcExtStatGreenBytesTx Counter64
  tnEvcExtStatYellowFrameRx Counter64
  tnEvcExtStatYellowFrameTx Counter64
  tnEvcExtStatYellowBytesRx Counter64
  tnEvcExtStatYellowBytesTx Counter64
  tnEvcExtStatRedFrameRx Counter64
  tnEvcExtStatRedBytesRx Counter64
  tnEvcExtStatDiscardFrameRx Counter64
  tnEvcExtStatDiscardFrameTx Counter64
  tnEvcExtStatDiscardBytesRx Counter64
  tnEvcExtStatDiscardBytesTx Counter64
  tnEvcExtStatclear TruthValue

TnEvcL2cpCfgEntry  
SEQUENCE    
  tnEvcL2cpCfgInterfaceNumber Unsigned32
  tnEvcL2cpCfgIndex Unsigned32
  tnEvcL2cpCfgType INTEGER
  tnEvcL2cpCfgMatchScope INTEGER
  tnEvcL2cpCfgMacAddress MacAddress
  tnEvcL2cpCfgProtocol Unsigned32
  tnEvcL2cpCfgSubType Unsigned32
  tnEvcL2cpCfgEvcName OCTET STRING
  tnEvcL2cpCfgValid INTEGER
  tnEvcL2cpCfgRowStatus RowStatus

Defined Values

tnEvcMib 1.3.6.1.4.1.868.2.5.106
TBD
MODULE-IDENTITY    

tnEvcObjects 1.3.6.1.4.1.868.2.5.106.1
OBJECT IDENTIFIER    

tnEvcCfgMgmtGroup 1.3.6.1.4.1.868.2.5.106.1.1
OBJECT IDENTIFIER    

tnEvcStatGroup 1.3.6.1.4.1.868.2.5.106.1.2
OBJECT IDENTIFIER    

tnEvcL2cpMgmtGroup 1.3.6.1.4.1.868.2.5.106.1.3
OBJECT IDENTIFIER    

tnEvcPortTable 1.3.6.1.4.1.868.2.5.106.1.1.1
This table displays and sets current EVC port configurations. This table has a sparse depedent relationship on the ifTable, containing a row for each ifEntry having an ifType of 'ethernetCsmacd' capable of supporting Ethernet services.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TnEvcPortEntry

tnEvcPortEntry 1.3.6.1.4.1.868.2.5.106.1.1.1.1
This entry represents an EVC port configuration.
Status: current Access: not-accessible
OBJECT-TYPE    
  TnEvcPortEntry  

tnEvcPortDEIMode 1.3.6.1.4.1.868.2.5.106.1.1.1.1.1
The DEI mode for an NNI port determines whether frames transmitted on the port will have the DEI field in the outer tag marked based on the colour of the frame. The allowed values are: 'coloured': The DEI is 1 for yellow frames and 0 for green frames. 'fixed': The DEI value is determined by ECE rules.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER coloured(1), fixed(2)  

tnEvcPortTagMode 1.3.6.1.4.1.868.2.5.106.1.1.1.1.2
The inner tag type is used to determine whether an inner tag is inserted in frames forwarded to NNI ports. The possible values are: 'inner': An inner tag is not inserted. 'outer': An inner C-tag is inserted.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER inner(1), outer(2)  

tnEvcPortAddressMode 1.3.6.1.4.1.868.2.5.106.1.1.1.1.3
The IP/MAC address mode specifying whether the EVC classification must be based on source (SMAC/SIP) or destination (DMAC/DIP) addresses. The allowed values are: 'source': Enable SMAC/SIP matching. 'destination': Enable DMAC/DIP matching.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER source(1), destination(2)  

tnEvcTable 1.3.6.1.4.1.868.2.5.106.1.1.2
This table contains the configuration of EVC(Ethernet Virtual Circuit).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TnEvcEntry

tnEvcEntry 1.3.6.1.4.1.868.2.5.106.1.1.2.1
This entry represents an EVC. Each entry in this table represents an EVC and can be created or deleted by the management system.
Status: current Access: not-accessible
OBJECT-TYPE    
  TnEvcEntry  

tnEvcIndex 1.3.6.1.4.1.868.2.5.106.1.1.2.1.1
The identifier of the EVC.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..11111  

tnEvcNNIPortlist 1.3.6.1.4.1.868.2.5.106.1.1.2.1.2
The list of Network to Network Interfaces for the EVC.
Status: current Access: read-create
OBJECT-TYPE    
  PortList  

tnEvcVid 1.3.6.1.4.1.868.2.5.106.1.1.2.1.3
The VLAN ID in the PB network. It may be inserted in a C-tag, S-tag or S-custom tag depending on the NNI port VLAN configuration. The allowed range is from 1 through 4094
Status: current Access: read-create
OBJECT-TYPE    
  VlanIdOrAny  

tnEvcIVid 1.3.6.1.4.1.868.2.5.106.1.1.2.1.4
The Internal/classified VLAN ID in the PB network. The allowed range is from 1 through 4094
Status: current Access: read-create
OBJECT-TYPE    
  VlanIdOrAny  

tnEvcLearning 1.3.6.1.4.1.868.2.5.106.1.1.2.1.5
The learning mode for the EVC controls whether source MAC addresses are learned for frames matching the EVC. Learning may be disabled if the EVC only includes two UNI/NNI ports. The allowed values are: Enabled: Learning is enabled (MAC addresses are learned). Disabled: Learning is disabled (MAC addresses are not learned).
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

tnEvcInnerTagType 1.3.6.1.4.1.868.2.5.106.1.1.2.1.6
The inner tag type is used to determine whether an inner tag is inserted in frames forwarded to NNI ports. The allowed values are: None: An inner tag is not inserted. cTag: An inner C-tag is inserted. sTag: An inner S-tag is inserted. sCustomTag: An inner tag is inserted and the tag type is determined by the VLAN port configuration of the NNI.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER none(1), cTag(2), sTag(3), sCustomTag(4)  

tnEvcInnerVidMode 1.3.6.1.4.1.868.2.5.106.1.1.2.1.7
The inner VID Mode affects the VID in the inner and outer tag. The allowed values are: normal: The VID of the two outer tags aren't swapped. tunnel: The VID of the two outer tags are swapped, so that the VID of the outer tag is taken from the Inner Tag configuration and the VID of the inner tag is the EVC VID. In this mode, the NNI ports are normally configured to do EVC classification based on the inner tag.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER normal(1), tunnel(2)  

tnEvcInnerVid 1.3.6.1.4.1.868.2.5.106.1.1.2.1.8
The Inner tag VLAN ID. The allowed range is from 0 through 4094.
Status: current Access: read-create
OBJECT-TYPE    
  VlanIdOrAnyOrNone  

tnEvcInnerPCPDEIPreservation 1.3.6.1.4.1.868.2.5.106.1.1.2.1.9
The inner tag PCP and DEI preservation. The allowed values are: Preserved: The inner tag PCP and DEI is preserved. Fixed: The inner tag PCP and DEI is fixed.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER preserved(1), fixed(2)  

tnEvcInnerPCP 1.3.6.1.4.1.868.2.5.106.1.1.2.1.10
The inner tag PCP value. The allowed range is from 0 through 7.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..7  

tnEvcInnerDEI 1.3.6.1.4.1.868.2.5.106.1.1.2.1.11
The inner tag DEI value. The allowed value is 0 or 1.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..1  

tnEvcOuterVid 1.3.6.1.4.1.868.2.5.106.1.1.2.1.12
The Outer tag VLAN ID. The allowed range is from 0 through 4094.
Status: current Access: read-create
OBJECT-TYPE    
  VlanIdOrAnyOrNone  

tnEvcStatus 1.3.6.1.4.1.868.2.5.106.1.1.2.1.13
The status of this conceptual row entry of EVC table. This object isused to manage the creation and deletion of conceptual rows. The status column has six defined values: - 'active', which indicates that the conceptual row is available for use by the managed device; - 'notInService', which indicates that the conceptual row exists in the agent, but is unavailable for use by the managed device (see NOTE below); - 'notReady', which indicates that the conceptual row exists in the agent, but is missing information necessary in order to be available for use by the managed device; - 'createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device; - 'createAndWait', which is supplied by a management station wishing to create a new instance of a conceptual row (but not make it available for use by the managed device); and, - 'destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. For a detailed description of this object, please refer to SNMPv2-TC MIB.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

tnEvcPolicerID 1.3.6.1.4.1.868.2.5.106.1.1.2.1.14
The ingress bandwidth profile mode for the EVC. The possible values are: Specific: The allowed range is from 1 through 128. Discard: All received frames are discarded for the EVC. The value is 4094. None: None bandwidth profile for the EVC. The value is 4095.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 1..4095  

tnEvcName 1.3.6.1.4.1.868.2.5.106.1.1.2.1.15
EVC Administrative Name.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..127)  

tnEvcEceTable 1.3.6.1.4.1.868.2.5.106.1.1.3
This table contains the configuration of EVC control entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TnEvcEceEntry

tnEvcEceEntry 1.3.6.1.4.1.868.2.5.106.1.1.3.1
This entry represents an ECE. The system automatically creates an entry when the system or the EMS/NMS creates a row in the cevcECETable. Likewise, the system automatically destroys an entry when the system or the EMS/NMS destroys the corresponding row in the cevcECETable.
Status: current Access: not-accessible
OBJECT-TYPE    
  TnEvcEceEntry  

tnEvcEceId 1.3.6.1.4.1.868.2.5.106.1.1.3.1.1
The identifier of the ECE.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..11111  

tnEvcEceNextEceId 1.3.6.1.4.1.868.2.5.106.1.1.3.1.2
Specify the created ECE is placed before which ECE.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER  

tnEvcEceUNIPortlist 1.3.6.1.4.1.868.2.5.106.1.1.3.1.3
The list of User to Network Interfaces for the ECE.
Status: current Access: read-create
OBJECT-TYPE    
  PortList  

tnEvcEceTagType 1.3.6.1.4.1.868.2.5.106.1.1.3.1.4
The tag type for the ECE. The possible values are: tagged: The ECE will match tagged frames only. untagged: The ECE will match untagged frames only. any: The ECE will match both tagged and untagged frames.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER tagged(1), untagged(2), any(3)  

tnEvcEceTagVIDFilterType 1.3.6.1.4.1.868.2.5.106.1.1.3.1.5
The VLAN ID filter for matching the ECE. It only significant if tag type 'Tagged' is selected. The possible values are: any: No VLAN ID filter is specified. (VLAN ID filter status is 'don't-care'.) specific: If you want to filter a specific VLAN ID value with this ECE, choose this value. A field for entering a specific value appears. range: If you want to filter a specific VLAN ID range filter with this ECE, choose this value. A field for entering a range appears.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER any(1), specific(2), range(3)  

tnEvcEceTagVIDFilterVal 1.3.6.1.4.1.868.2.5.106.1.1.3.1.6
When 'Specific' is selected for the VLAN ID filter, you can enter a specific value. The allowed value is from 0 through 4094.
Status: current Access: read-create
OBJECT-TYPE    
  VlanIdOrAnyOrNone  

tnEvcEceTagVIDFilterStart 1.3.6.1.4.1.868.2.5.106.1.1.3.1.7
When 'Range' is selected for the VLAN ID filter, you can enter a specific range. The allowed range start is from 0 through 4094.
Status: current Access: read-create
OBJECT-TYPE    
  VlanIdOrAnyOrNone  

tnEvcEceTagVIDFilterEnd 1.3.6.1.4.1.868.2.5.106.1.1.3.1.8
When 'Range' is selected for the VLAN ID filter, you can enter a specific range. The allowed range end is from 0 through 4094.
Status: current Access: read-create
OBJECT-TYPE    
  VlanIdOrAnyOrNone  

tnEvcEceTagPCP 1.3.6.1.4.1.868.2.5.106.1.1.3.1.9
The PCP value for mataching the ECE. It only significant if tag type 'Tagged' is selected. The possible values are: any: The ECE will match any PCP value(all bits will be set to 1). specific: each bit matchs a specific PCP of ECE(from bit0 to bit7). range: The ECE will match PCP values in the selected range, valid range bit0-bit1, bit2-bit3, bit4-bit5, bit6-bit7, bit0-bit3 or bit4-bit7.
Status: current Access: read-create
OBJECT-TYPE    
  BITS none(0)  

tnEvcEceTagDEI 1.3.6.1.4.1.868.2.5.106.1.1.3.1.10
The DEI value for mataching the ECE. It only significant if tag type 'Tagged' is selected. The allowed value is: 0, 1 or Any.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER any(1), dei0(2), dei1(3)  

tnEvcEceTagFrameType 1.3.6.1.4.1.868.2.5.106.1.1.3.1.11
The frame type for the ECE. The possible values are: any: The ECE will match any frame type. etype: The ECE will match Ethernet Type frames only. llc: The ECE will match LLC frames only. snap: The ECE will match SNAP frames only. ipv4: The ECE will match IPv4 frames only. ipv6: The ECE will match IPv6 frames only. l2cp: The ECE will match L2CP frames only.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER any(1), etype(2), llc(3), snap(4), ipv4(5), ipv6(6), l2cp(7)  

tnEvcEceProtoType 1.3.6.1.4.1.868.2.5.106.1.1.3.1.12
The IP protocol for matching the ECE. The possible values are: any: No protocol filter is specified. (Protocol filter status is 'don't-care'.) udp: Specify the UDP for matching the ECE. tcp: Specify the TCP for matching the ECE. other: If you want to filter a specific protocol value with this ECE, choose this value. A field for entering a specific value appears.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER any(1), udp(2), tcp(3), other(4)  

tnEvcEceProtoVal 1.3.6.1.4.1.868.2.5.106.1.1.3.1.13
When 'Specific' is selected for the protocol filter, you can enter a specific value. The allowed value is from 0 through 255.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..255  

tnEvcEceDscpFilterType 1.3.6.1.4.1.868.2.5.106.1.1.3.1.14
The DSCP filter for matching the ECE. The possible values are: any: No DSCP filter is specified. (DSCP filter status is 'don't-care'.) specific: If you want to filter a specific DSCP value with this ECE, choose this value. A field for entering a specific value appears. range: If you want to filter a specific DSCP range filter with this ECE, choose this value. A field for entering a range appears.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER any(1), specific(2), range(3)  

tnEvcEceDscpFilterVal 1.3.6.1.4.1.868.2.5.106.1.1.3.1.15
When 'Specific' is selected for the DSCP filter, you can enter a specific value. The allowed value is from 0 through 63.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..63  

tnEvcEceDscpRangeStart 1.3.6.1.4.1.868.2.5.106.1.1.3.1.16
When 'Range' is selected for the DSCP filter, you can enter a specific range. The allowed range start is from 0 through 63.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..63  

tnEvcEceDscpRangeEnd 1.3.6.1.4.1.868.2.5.106.1.1.3.1.17
When 'Range' is selected for the DSCP filter, you can enter a specific range. The allowed range end is from 0 through 63.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..63  

tnEvcEceSrcPortFilterType 1.3.6.1.4.1.868.2.5.106.1.1.3.1.18
The TCP/UDP source port for matching the ECE. It only significant if protocol filter 'UDP' or 'TCP' is selected. The possible values are: any: No TCP/UDP source port filter is specified. (Source port filter status is 'don't-care'.) specific: If you want to filter a specific TCP/UDP source port No. with this ECE, choose this value. A field for entering a specific No. appears. range: If you want to filter a specific TCP/UDP source port range filter with this ECE, choose this value. A field for entering a range appears.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER any(1), specific(2), range(3)  

tnEvcEceSrcPortFilterNo 1.3.6.1.4.1.868.2.5.106.1.1.3.1.19
When 'Specific' is selected for the source port filter, you can enter a specific value. The allowed value is from 0 through 65535.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..65535  

tnEvcEceSrcPortRangeStart 1.3.6.1.4.1.868.2.5.106.1.1.3.1.20
When 'Range' is selected for the source port filter, you can enter a specific range. The allowed range start is from 0 through 65535.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..65535  

tnEvcEceSrcPortRangeEnd 1.3.6.1.4.1.868.2.5.106.1.1.3.1.21
When 'Range' is selected for the source port filter, you can enter a specific range. The allowed range end is from 0 through 65535.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..65535  

tnEvcEceDstPortFilterType 1.3.6.1.4.1.868.2.5.106.1.1.3.1.22
The TCP/UDP destination port for matching the ECE. It only significant if protocol filter 'UDP' or 'TCP' is selected. The possible values are: any: No TCP/UDP destination port filter is specified. (Source port filter status is 'don't-care'.) specific: If you want to filter a specific TCP/UDP source port No. with this ECE, choose this value. A field for entering a specific No. appears. range: If you want to filter a specific TCP/UDP source port range filter with this ECE, choose this value. A field for entering a range appears.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER any(1), specific(2), range(3)  

tnEvcEceDstPortFilterNo 1.3.6.1.4.1.868.2.5.106.1.1.3.1.23
When 'Specific' is selected for the destination port filter, you can enter a specific value. The allowed value is from 0 through 65535.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..65535  

tnEvcEceDstPortRangeStart 1.3.6.1.4.1.868.2.5.106.1.1.3.1.24
When 'Range' is selected for the destination port filter, you can enter a specific range. The allowed range start is from 0 through 65535.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..65535  

tnEvcEceDstPortRangeEnd 1.3.6.1.4.1.868.2.5.106.1.1.3.1.25
When 'Range' is selected for the destination port filter, you can enter a specific range. The allowed range end is from 0 through 65535.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..65535  

tnEvcEceIpv4DipSipFilter 1.3.6.1.4.1.868.2.5.106.1.1.3.1.26
The source/destination IP address for matching the ECE. It depend on by the port address mode, when port address mode is set to 'Source' then the field is used for source address. Similarly when port address mode is set to 'Destination' then the field is used for destination address. The possible values are: Any: No SIP/DIP filter is specified. (SIP/DIP filter status is 'don't-care'.) Host: If you want to filter a specific host address with this ECE, choose this value. A field for entering a host address appears. Network: If you want to filter a specific network address with this ECE, choose this value. A Two fields for entering a specific network address and network mask appears.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER any(1), host(2), network(3)  

tnEvcEceIpv4DipSipAddr 1.3.6.1.4.1.868.2.5.106.1.1.3.1.27
When 'Host' or 'Network' is selected for the SIP/DIP filter, you can enter a specific host or network address.
Status: current Access: read-create
OBJECT-TYPE    
  InetAddress  

tnEvcEceIpv4DipSipMask 1.3.6.1.4.1.868.2.5.106.1.1.3.1.28
When 'Host' or 'Network' is selected for the SIP/DIP filter, you can enter a specific network mask.
Status: current Access: read-create
OBJECT-TYPE    
  InetAddress  

tnEvcEceIpv4Fragment 1.3.6.1.4.1.868.2.5.106.1.1.3.1.29
The IPv4 Fragment for matching the ECE. This involves the settings for the More Fragments (MF) bit and the Fragment Offset (FRAG OFFSET) field for an IPv4 frame. The possible values are: any: The ECE will match any MF bit. fragment: IPv4 frames where the MF bit is set or the FRAG OFFSET field is greater than zero must be able to match this entry. nonfragment: IPv4 frames where the MF bit is set or the FRAG OFFSET field is greater than zero must not be able to match this entry.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER any(1), fragment(2), nonfragment(3)  

tnEvcEceIpv6DipSipFilter 1.3.6.1.4.1.868.2.5.106.1.1.3.1.30
The source/destination IP address for matching the ECE. It depend on by the port address mode, when port address mode is set to 'Source' then the field is used for source address. Similarly when port address mode is set to 'Destination' then the field is used for destination address. The possible values are: Any: No SIP/DIP filter is specified. (SIP/DIP filter status is 'don't-care'.) specific: If you want to filter a specific host address with this ECE, choose this value. A field for entering a host address appears.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER any(1), specific(2)  

tnEvcEceIpv6DipSipAddr 1.3.6.1.4.1.868.2.5.106.1.1.3.1.31
When 'Host' or 'Network' is selected for the SIP/DIP filter, you can enter a specific host or network address. When 'IPv6' is selected for the Frame Type, the field only supported 32 bits for IPv6 address.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

tnEvcEceIpv6DipSipMask 1.3.6.1.4.1.868.2.5.106.1.1.3.1.32
When 'Host' or 'Network' is selected for the SIP/DIP filter, you can enter a specific network mask. When 'IPv6' is selected for the Frame Type, the field only supported 32 bits for IPv6 address mask.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

tnEvcEceOuterMode 1.3.6.1.4.1.868.2.5.106.1.1.3.1.33
The outer tag PCP and DEI preservation for the ECE. The possible values are: enabled: Enable outer tag for nni-to-uni direction for the ECE. disabled: Disable outer tag for nni-to-uni direction for the ECE.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

tnEvcEceOuterPCPDEIPreserve 1.3.6.1.4.1.868.2.5.106.1.1.3.1.34
The outer tag PCP and DEI preservation for the ECE. The possible values are: preserved: The outer tag PCP and DEI is preserved. fixed: The outer tag PCP and DEI is fixed.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER preserved(1), fixed(2)  

tnEvcEceOuterPCP 1.3.6.1.4.1.868.2.5.106.1.1.3.1.35
The outer tag PCP value for the ECE. The allowed range is from 0 through 7.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..7  

tnEvcEceOuterDEI 1.3.6.1.4.1.868.2.5.106.1.1.3.1.36
The outer tag DEI value for the ECE. The allowed value is 0 or 1.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..1  

tnEvcEceActDirection 1.3.6.1.4.1.868.2.5.106.1.1.3.1.37
The EVCs and ECEs are used to setup flows in one or both directions as determined by the ECE Direction parameter. If the ECE is bidirectional, the ingress rules of the NNI ports will be setup to match the traffic being forwarded to NNI ports. The possible values are: both: Bidirectional. uni2nni: Unidirectional from UNI to NNI. nni2uni: Unidirectional from NNI to UNI.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER both(1), uni2nni(2), nni2uni(3)  

tnEvcEceActEvcidFilterType 1.3.6.1.4.1.868.2.5.106.1.1.3.1.38
The outer tag PCP and DEI preservation for the ECE. The possible values are: any: No EVC ID filter is specified. (EVC ID filter status is 'don't-care'.) specific: If you want to filter a specific EVC ID with this ECE, choose this value. A field for entering a specific value appears.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER any(1), specific(2)  

tnEvcEceActEvcidVal 1.3.6.1.4.1.868.2.5.106.1.1.3.1.39
When 'Specific' is selected for the VLAN ID filter, you can enter a specific value. The allowed value is from 1 through 128.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 1..128  

tnEvcEceActTagPopCount 1.3.6.1.4.1.868.2.5.106.1.1.3.1.40
The ingress tag pop count for the ECE. The allowed range is from 0 through 2.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..2  

tnEvcEceActPolicyId 1.3.6.1.4.1.868.2.5.106.1.1.3.1.41
The ACL Policy ID for the ECE for matching ACL rules. The allowed range is from 0 through 255.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..255  

tnEvcEceActClass 1.3.6.1.4.1.868.2.5.106.1.1.3.1.42
The traffic class for the ECE. The allowed range is from 0 through 8 or disabled.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER tc0(1), tc1(2), tc2(3), tc3(4), tc4(5), tc5(6), tc6(7), tc7(8), disabled(9)  

tnEvcEceDMacSMacFilterType 1.3.6.1.4.1.868.2.5.106.1.1.3.1.43
The source/destination MAC address for matching the ECE. It depend on by the port address mode, when port address mode is set to 'Source' then the field is used for source MAC address. Similarly when port address mode is set to 'Destination' then the field is used for destination MAC address. The possible values are: any: No SMAC/DMAC filter is specified. (SMAC/DMAC filter status is 'don't-care'.) specific: If you want to filter a specific SMAC/DMAC value with this ECE, choose this value. A field for entering a specific value appears.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER any(1), specific(2)  

tnEvcEceDMacSMacVal 1.3.6.1.4.1.868.2.5.106.1.1.3.1.44
When 'Specific' is selected for the SMAC/DMAC filter, you can enter a specific value. The legal format is 'xx-xx-xx-xx-xx-xx' or 'xx.xx.xx.xx.xx.xx' or 'xxxxxxxxxxxx' (x is a hexadecimal digit).
Status: current Access: read-create
OBJECT-TYPE    
  MacAddress  

tnEvcEceDMacType 1.3.6.1.4.1.868.2.5.106.1.1.3.1.45
The destination MAC address for matching the ECE. The possible values are: any: No destination MAC address is specified. unicast: Frame must be unicast. multicast: Frame must be multicast. broadcast: Frame must be broadcast. specific: If you want to filter a specific DMAC value with this ECE, choose this value.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER any(1), unicast(2), multicast(3), broadcast(4), specific(5)  

tnEvcEceConflict 1.3.6.1.4.1.868.2.5.106.1.1.3.1.46
Indicates the hardware status of the specific ECE. The specific ECE is not applied to the hardware due to hardware limitations.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

tnEvcEceStatus 1.3.6.1.4.1.868.2.5.106.1.1.3.1.47
The status of this conceptual row entry of ECE table. This object isused to manage the creation and deletion of conceptual rows. The status column has six defined values: - 'active', which indicates that the conceptual row is available for use by the managed device; - 'notInService', which indicates that the conceptual row exists in the agent, but is unavailable for use by the managed device (see NOTE below); - 'notReady', which indicates that the conceptual row exists in the agent, but is missing information necessary in order to be available for use by the managed device; - 'createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device; - 'createAndWait', which is supplied by a management station wishing to create a new instance of a conceptual row (but not make it available for use by the managed device); and, - 'destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. For a detailed description of this object, please refer to SNMPv2-TC MIB.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

tnEvcBandwidthProfilesTable 1.3.6.1.4.1.868.2.5.106.1.1.4
This entry displays and sets current EVC ingress bandwidth profile configurations. These policers may be used to limit the traffic received on UNI ports.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TnEvcBandwidthProfilesEntry

tnEvcBandwidthProfilesEntry 1.3.6.1.4.1.868.2.5.106.1.1.4.1
This entry represents an entry of EVC ingress bandwidth profile configuration.
Status: current Access: not-accessible
OBJECT-TYPE    
  TnEvcBandwidthProfilesEntry  

tnEvcBandwidthProfilesIndex 1.3.6.1.4.1.868.2.5.106.1.1.4.1.1
The EVC bandwidth profiles policer index.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..11111  

tnEvcBandwidthProfilesPolicerMode 1.3.6.1.4.1.868.2.5.106.1.1.4.1.2
The colour mode of the bandwidth profile. The allowed values are: coupled: Colour-aware mode with coupling enabled. aware: Colour-aware mode with coupling disabled.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER coupled(1), aware(2), blind(3)  

tnEvcBandwidthProfilesCIR 1.3.6.1.4.1.868.2.5.106.1.1.4.1.3
The Committed Information Rate of the bandwidth profile. The allowed range is from 0 through 10,000,000 kilobit per second.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..10000000  

tnEvcBandwidthProfilesCBS 1.3.6.1.4.1.868.2.5.106.1.1.4.1.4
The Committed Burst Size of the bandwidth profile. The allowed range is from 0 through 100,000 bytes.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..100000  

tnEvcBandwidthProfilesEIR 1.3.6.1.4.1.868.2.5.106.1.1.4.1.5
The Excess Information Rate of the bandwidth profile. The allowed range is from 0 through 10,000,000 kilobit per second.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..10000000  

tnEvcBandwidthProfilesEBS 1.3.6.1.4.1.868.2.5.106.1.1.4.1.6
The Excess Burst Size of the bandwidth profile. The allowed range is from 0 through 100,000 bytes.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..100000  

tnEvcBandwidthProfilesState 1.3.6.1.4.1.868.2.5.106.1.1.4.1.7
The administrative state of the bandwidth profile. The allowed values are: enabled: The bandwidth profile enabled. disabled: The bandwidth profile is disabled.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

tnEvcExtEceTable 1.3.6.1.4.1.868.2.5.106.1.1.5
This table contains the configuration of EVC control entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TnEvcExtEceEntry

tnEvcExtEceEntry 1.3.6.1.4.1.868.2.5.106.1.1.5.1
This entry represents an ECE. The system automatically creates an entry when the system or the EMS/NMS creates a row in the cevcECETable. Likewise, the system automatically destroys an entry when the system or the EMS/NMS destroys the corresponding row in the cevcECETable.
Status: current Access: not-accessible
OBJECT-TYPE    
  TnEvcExtEceEntry  

tnEvcEceInnerTagType 1.3.6.1.4.1.868.2.5.106.1.1.5.1.1
The Inner tag type for the ECE. The possible values are: tagged: The ECE will match tagged frames only. untagged: The ECE will match untagged frames only. any: The ECE will match both tagged and untagged frames. If supported: C-Tagged: The ECE will match custom tagged frames only. S-Tagged: The ECE will match service tagged frames only.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER any(1), untagged(2), tagged(3), c-tag(4), s-tag(5)  

tnEvcEceInnerTagVIDFilterType 1.3.6.1.4.1.868.2.5.106.1.1.5.1.2
The Inner VLAN ID filter for matching the ECE. It only significant if tag type 'Tagged' is selected. The possible values are: any: No VLAN ID filter is specified. (VLAN ID filter status is 'don't-care'.) specific: If you want to filter a specific VLAN ID value with this ECE, choose this value. A field for entering a specific value appears. range: If you want to filter a specific VLAN ID range filter with this ECE, choose this value. A field for entering a range appears.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER any(1), specific(2), range(3)  

tnEvcEceInnerTagVIDFilterVal 1.3.6.1.4.1.868.2.5.106.1.1.5.1.3
When 'Specific' is selected for the Inner VLAN ID filter, you can enter a specific value. The allowed value is from 0 through 4094.
Status: current Access: read-create
OBJECT-TYPE    
  VlanIdOrNone  

tnEvcEceInnerTagVIDFilterStart 1.3.6.1.4.1.868.2.5.106.1.1.5.1.4
When 'Range' is selected for the Inner VLAN ID filter, you can enter a specific range. The allowed range start is from 0 through 4094.
Status: current Access: read-create
OBJECT-TYPE    
  VlanIdOrNone  

tnEvcEceInnerTagVIDFilterEnd 1.3.6.1.4.1.868.2.5.106.1.1.5.1.5
When 'Range' is selected for the Inner VLAN ID filter, you can enter a specific range. The allowed range end is from 0 through 4094.
Status: current Access: read-create
OBJECT-TYPE    
  VlanIdOrNone  

tnEvcEceInnerTagPCP 1.3.6.1.4.1.868.2.5.106.1.1.5.1.6
The PCP value for matching the ECE. It only significant if tag type 'Tagged' is selected. The possible values are: any: The ECE will match any PCP value(all bits will be set to 1). specific: each bit matchs a specific PCP of ECE(from bit0 to bit7). range: The ECE will match PCP values in the selected range, valid range bit0-bit1, bit2-bit3, bit4-bit5, bit6-bit7, bit0-bit3 or bit4-bit7.
Status: current Access: read-create
OBJECT-TYPE    
  BITS none(0)  

tnEvcEceInnerTagDEI 1.3.6.1.4.1.868.2.5.106.1.1.5.1.7
The DEI value for matching the ECE. It only significant if tag type 'Tagged' is selected. The allowed value is: 0, 1 or Any.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER any(1), dei0(2), dei1(3)  

tnEvcEcePolicer 1.3.6.1.4.1.868.2.5.106.1.1.5.1.8
The ingress bandwidth profile mode for the EVC. The possible values are: Specific: The allowed range is from 1 through 128. Discard: All received frames are discarded for the EVC. The value is 4094. None: None bandwidth profile for the EVC. The value is 4095. EVC:The bandwidth profile for the specified EVC ID is used. The value is 4096.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 1..4096  

tnEvcEceOuterVid 1.3.6.1.4.1.868.2.5.106.1.1.5.1.9
The EVC outer tag VID for UNI ports. The allowed value is from 0 through 4094.
Status: current Access: read-create
OBJECT-TYPE    
  VlanIdOrNone  

tnEvcEceNNIInnerTagType 1.3.6.1.4.1.868.2.5.106.1.1.5.1.10
The inner type for the ECE determines whether an inner tag is inserted in frames forwarded to NNI ports.\ The possible values are: None: An inner tag is not inserted. C-tag: An inner C-tag is inserted. S-tag: An inner S-tag is inserted. S-custom-tag: An inner tag is inserted and the tag type is determined by the VLAN port configuration of the NNI.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER none(0), ctag(1), stag(2), sctag(3)  

tnEvcEceInnerVid 1.3.6.1.4.1.868.2.5.106.1.1.5.1.11
The inner tag VLAN ID for the ECE. The allowed range is from 0 through 4094.
Status: current Access: read-create
OBJECT-TYPE    
  VlanIdOrNone  

tnEvcEceInnerPCPDEIPreserve 1.3.6.1.4.1.868.2.5.106.1.1.5.1.12
The inner tag PCP and DEI preservation for the ECE. The possible values are: Preserved: The inner tag PCP and DEI is preserved. Fixed: The inner tag PCP and DEI is fixed.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER preserved(1), fixed(2)  

tnEvcEceInnerPCP 1.3.6.1.4.1.868.2.5.106.1.1.5.1.13
The inner tag PCP value for the ECE. The allowed range is from 0 through 7.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..7  

tnEvcEceInnerDEI 1.3.6.1.4.1.868.2.5.106.1.1.5.1.14
The inner tag DEI value for the ECE. The allowed value is 0 or 1.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..1  

tnEvcEceDMacVal 1.3.6.1.4.1.868.2.5.106.1.1.5.1.15
When 'Specific' is selected for the DMAC filter, you can enter a specific value. The legal format is 'xx-xx-xx-xx-xx-xx' or 'xx.xx.xx.xx.xx.xx' or 'xxxxxxxxxxxx' (x is a hexadecimal digit).
Status: current Access: read-write
OBJECT-TYPE    
  MacAddress  

tnEvcEceOuterPCPMode 1.3.6.1.4.1.868.2.5.106.1.1.5.1.16
The outer tag PCP mode for the ECE. The possible values are: Classified: The outer tag PCP Mode is classified. Fixed: The outer tag PCP Mode is fixed. Mapped: The outer tag PCP Mode is based on mapped (QOS, DP).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER classified(1), fixed(2), mapped(3)  

tnEvcEceOuterDEIMode 1.3.6.1.4.1.868.2.5.106.1.1.5.1.17
The outer tag DEI mode for the ECE. The possible values are: Classified: The outer tag DEI mode is classified. Fixed: The outer tag DEI mode is fixed. Drop Precedence: The outer tag DEI mode is drop precedence.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER classified(1), fixed(2), dropPrec(3)  

tnEvcEceActRuleType 1.3.6.1.4.1.868.2.5.106.1.1.5.1.18
The rule type for the ECE. The possible values are: Both: Ingress and egress rule. RX: Ingress rule. TX: Egress rule.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER both(1), rx(2), tx(3)  

tnEvcEceActTxLookupType 1.3.6.1.4.1.868.2.5.106.1.1.5.1.19
The TX lookup for the ECE. The possible values are: VID lookup: The TX lookup is based on VID. VID-PCP: The TX lookup is based on VID and PCP. ISDX: The TX lookup is based on ISDX.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER vidLookup(1), vidPCP(2), isdx(3)  

tnEvcEceActDropPrecType 1.3.6.1.4.1.868.2.5.106.1.1.5.1.20
The drop precedence for the ECE. The allowed range is 0, 1 or disabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER dp0(1), dp1(2), disabled(3)  

tnEvcEceInnerPcpMode 1.3.6.1.4.1.868.2.5.106.1.1.5.1.21
The inner tag PCP mode for the ECE. The possible values are: Classified: The inner tag PCP Mode is classified. Fixed: The inner tag PCP Mode is classified. Mapped: The inner tag PCP Mode is based on mapped (QOS, DP).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER classified(1), fixed(2), mapped(3)  

tnEvcEceIInnerDeiMode 1.3.6.1.4.1.868.2.5.106.1.1.5.1.22
The inner tag DEI mode for the ECE. The possible values are: Classified: The inner tag DEI mode is classified. Fixed: The inner tag DEI mode is fixed. Drop Precedence: The inner tag DEI mode is drop precedence.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER classified(1), fixed(2), dropPrecedence(3)  

tnEvcEceIpv4DipFilter 1.3.6.1.4.1.868.2.5.106.1.1.5.1.23
The destination IP address for matching the ECE. The possible values are: Any: No DIP filter is specified. (DIP filter status is 'don't-care'.) Host: If you want to filter a specific host address with this ECE, choose this value. A field for entering a host address appears. Network: If you want to filter a specific network address with this ECE, choose this value. A Two fields for entering a specific network address and network mask appears.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER any(1), host(2), network(3)  

tnEvcEceIpv4DipAddr 1.3.6.1.4.1.868.2.5.106.1.1.5.1.24
When 'Host' or 'Network' is selected for the DIP filter, you can enter a specific host or network address.
Status: current Access: read-write
OBJECT-TYPE    
  InetAddress  

tnEvcEceIpv4DipMask 1.3.6.1.4.1.868.2.5.106.1.1.5.1.25
When 'Host' or 'Network' is selected for the DIP filter, you can enter a specific network mask.
Status: current Access: read-write
OBJECT-TYPE    
  InetAddress  

tnEvcEceIpv6DipFilter 1.3.6.1.4.1.868.2.5.106.1.1.5.1.26
The destination IP address for matching the ECE. The possible values are: Any: No DIP filter is specified. (DIP filter status is 'don't-care'.) Host: If you want to filter a specific host address with this ECE, choose this value. A field for entering a host address appears. Network: If you want to filter a specific network address with this ECE, choose this value. A Two fields for entering a specific network address and network mask appears.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER any(1), host(2), network(3)  

tnEvcEceIpv6DipAddr 1.3.6.1.4.1.868.2.5.106.1.1.5.1.27
When 'Host' or 'Network' is selected for the DIP filter, you can enter a specific host or network address.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tnEvcEceIpv6DipMask 1.3.6.1.4.1.868.2.5.106.1.1.5.1.28
When 'Host' or 'Network' is selected for the DIP filter, you can enter a specific network mask.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tnEvcEceLookup 1.3.6.1.4.1.868.2.5.106.1.1.5.1.29
The looup type for matching the ECE. The allowed values are: Basic: First lookup for basic classification. Advanced: Second lookup for advanced classification.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER basic(1), advanced(2)  

tnEvcEceEtypeFilter 1.3.6.1.4.1.868.2.5.106.1.1.5.1.30
The Ethernet type value for matching the ECE. The possible values are: Any: No Ethernet type value filter is specified. (Ethernet type filter status is 'don't-care'.) Specific: If you want to filter a specific Ethernet type value with this ECE, choose this value.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER any(1), specific(2)  

tnEvcEceEtypeValue 1.3.6.1.4.1.868.2.5.106.1.1.5.1.31
When 'Specific' is selected for the Ethernet type filter, you can enter a specific value. The allowed value is from 0x600 through 0xFFFF but exclude 0x0800(IPv4), 0x806(ARP) and 0x86DD(IPv6).
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tnEvcEceEtypeDataFilter 1.3.6.1.4.1.868.2.5.106.1.1.5.1.32
The Ethernet type data for matching the ECE. The possible values are: Any: No Ethernet type data filter is specified. (Ethernet type filter status is 'don't-care'.) Specific: If you want to filter a specific Ethernet type value with this ECE, choose this value.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER any(1), specific(2)  

tnEvcEceEtypeData 1.3.6.1.4.1.868.2.5.106.1.1.5.1.33
When 'Specific' is selected for the Ethernet type filter, you can enter a specific value. The allowed value is from 0x600 through 0xFFFF but exclude 0x0800(IPv4), 0x806(ARP) and 0x86DD(IPv6).
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tnEvcEceEtypeDataMask 1.3.6.1.4.1.868.2.5.106.1.1.5.1.34
When 'Specific' is selected for the Ethernet type data filter, you can enter a specific value. It is a pair of the Ethernet type data and its mask. The allowed value is from 0x0 through 0xFFFF.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tnEvcEceLlcDSAPFilter 1.3.6.1.4.1.868.2.5.106.1.1.5.1.35
The LLC DSAP for matching the ECE. The possible values are: Any: No LLC DSAP value filter is specified. (LLC DSAP filter status is 'don't-care'.) Specific: If you want to filter a specific LLC DSAP value with this ECE, choose this value.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER any(1), specific(2)  

tnEvcEceLlcDSAPValue 1.3.6.1.4.1.868.2.5.106.1.1.5.1.36
When 'Specific' is selected for the LLC DSAP filter, you can enter a specific value. The allowed value is from 0x0 through 0xFF
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tnEvcEceLlcSSAPFilter 1.3.6.1.4.1.868.2.5.106.1.1.5.1.37
The LLC SSAP for matching the ECE. The possible values are: Any: No LLC SSAP value filter is specified. (LLC SSAP filter status is 'don't-care'.) Specific: If you want to filter a specific LLC SSAP value with this ECE, choose this value.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER any(1), specific(2)  

tnEvcEceLlcSSAPValue 1.3.6.1.4.1.868.2.5.106.1.1.5.1.38
When 'Specific' is selected for the LLC SSAP filter, you can enter a specific value. The allowed value is from 0x0 through 0xFF.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tnEvcEceLlcCtrlFilter 1.3.6.1.4.1.868.2.5.106.1.1.5.1.39
The LLC control for matching the ECE. The possible values are: Any: No LLC control value filter is specified. (LLC control filter status is 'don't-care'.) Specific: If you want to filter a specific LLC control value with this ECE, choose this value.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER any(1), specific(2)  

tnEvcEceLlcCtrlValue 1.3.6.1.4.1.868.2.5.106.1.1.5.1.40
When 'Specific' is selected for the LLC control filter, you can enter a specific value. The allowed value is from 0x0 through 0xFF.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tnEvcEceLlcDataFilter 1.3.6.1.4.1.868.2.5.106.1.1.5.1.41
The LLC data for matching the ECE. The possible values are: Any: No LLC data filter is specified. (LLC filter status is 'don't-care'.) Specific: If you want to filter a specific LLC value with this ECE, choose this value.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER any(1), specific(2)  

tnEvcEceLlcDataValue 1.3.6.1.4.1.868.2.5.106.1.1.5.1.42
When 'Specific' is selected for the LLC data filter, you can enter a specific value. It is a pair of the LLC data and its mask. The allowed value is from 0x0 through 0xFFFF.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tnEvcEceLlcDataMask 1.3.6.1.4.1.868.2.5.106.1.1.5.1.43
When 'Specific' is selected for the LLC data filter, you can enter a specific mask. The allowed value is from 0x0 through 0xFFFF.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tnEvcEceSnapOuiFilter 1.3.6.1.4.1.868.2.5.106.1.1.5.1.44
The SNAP OUI for matching the ECE. The possible values are: Any: No SNAP OUI value filter is specified. (SNAP OUI filter status is 'don't-care'.) Specific: If you want to filter a specific SNAP OUI value with this ECE, choose this value.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER any(1), specific(2)  

tnEvcEceSnapOuiValue 1.3.6.1.4.1.868.2.5.106.1.1.5.1.45
When 'Specific' is selected for the SNAP OUI filter, you can enter a specific value. The allowed value is from 00-00-00 through FF-FF-FF.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tnEvcEceSnapPidFilter 1.3.6.1.4.1.868.2.5.106.1.1.5.1.46
The SNAP PID for matching the ECE. The possible values are: Any: No SNAP PID value filter is specified. (SNAP PID filter status is 'don't-care'.) Specific: If you want to filter a specific SNAP PID value with this ECE, choose this value.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER any(1), specific(2)  

tnEvcEceSnapPidValue 1.3.6.1.4.1.868.2.5.106.1.1.5.1.47
When 'Specific' is selected for the SNAP PID filter, you can enter a specific value. The allowed value is from 0x0 through 0xFFFF.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

tnEvcEceL2cpProtoType 1.3.6.1.4.1.868.2.5.106.1.1.5.1.48
The L2CP type for the ECE. The possible values are: STP/RSTP/MSTP: Match STP/RSTP/MSTP frames. Pause: Match Pause frames. LACP: Match LACP frames. LAMP: Match LAMP frames. Link OAM(802.1ah): Match Link OAM(802.1ah) frames. Port Authentication(802.1x): Match Port Authentication(802.1x) frames. E-LMI: Match PB Group Address frames. PB Group Address: Match PB Group Address frames. PB GVRP: Match PB GVRP frames. LLDP: Match LLDP frames. GMRP: Match GMRP frames. GVRP: Match GVRP frames. ULD: Match ULD frames. PAgP: Match PAgP frames. PVST/PVST+: Match PVST/PVST+ frames. Cisco BPDU: Match Cisco BPDU frames. CDP: Match CDP frames. VTP: Match VTP frames. DTP: Match DTP frames. STP Uplink Fast: Match STP Uplink Fast frames. Cisco CFM: Match Cisco CFM frames.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER stpRstpMstp(1), pause(2), lacp(3), lamp(4), linkOam(5), portAuth8021x(6), elmi(7), pbGroupAddr(8), pbGvrp(9), lldp(10), gmrp(11), gvrp(12), uld(13), pagp(14), pvstPvstP(15), ciscoBpdu(16), cdp(17), vtp(18), dtp(19), stpUplinkFast(20), ciscoCfm(21)  

tnEvcStatTable 1.3.6.1.4.1.868.2.5.106.1.2.1
This table provides NNI port traffic statistics for the selected EVC. It also shows counters for UNI ports of ECEs mapping to the EVC.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TnEvcStatEntry

tnEvcStatEntry 1.3.6.1.4.1.868.2.5.106.1.2.1.1
This entry represents an entry of EVC statistics.
Status: current Access: not-accessible
OBJECT-TYPE    
  TnEvcStatEntry  

tnEvcStatClass 1.3.6.1.4.1.868.2.5.106.1.2.1.1.1
The traffic class for the EVC.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..11111  

tnEvcStatGreenFrameRx 1.3.6.1.4.1.868.2.5.106.1.2.1.1.2
The number of green received.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

tnEvcStatGreenFrameTx 1.3.6.1.4.1.868.2.5.106.1.2.1.1.3
The number of green transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

tnEvcStatYellowFrameRx 1.3.6.1.4.1.868.2.5.106.1.2.1.1.4
The number of yellow received.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

tnEvcStatYellowFrameTx 1.3.6.1.4.1.868.2.5.106.1.2.1.1.5
The number of yellow transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

tnEvcStatRedFrameRx 1.3.6.1.4.1.868.2.5.106.1.2.1.1.6
The number of red received.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

tnEvcStatDiscardGreenFrame 1.3.6.1.4.1.868.2.5.106.1.2.1.1.7
The number of discarded in the green color.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

tnEvcStatDiscardYellowFrame 1.3.6.1.4.1.868.2.5.106.1.2.1.1.8
The number of discarded in the yellow color.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

tnEvcStatClear 1.3.6.1.4.1.868.2.5.106.1.2.1.1.9
Clears the counters for selected ports when the value of tnEvcStatClear is true.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

tnEvcExtStatTable 1.3.6.1.4.1.868.2.5.106.1.2.2
This table provides port traffic statistics for the selected EVC. It also shows counters for UNI ports of ECEs mapping to the EVC.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TnEvcExtStatEntry

tnEvcExtStatEntry 1.3.6.1.4.1.868.2.5.106.1.2.2.1
This entry represents an entry of EVC statistics.
Status: current Access: not-accessible
OBJECT-TYPE    
  TnEvcExtStatEntry  

tnEvcExtStatType 1.3.6.1.4.1.868.2.5.106.1.2.2.1.1
The traffic class for the EVC.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER evc(1), ece(2)  

tnEvcExtStatIndex 1.3.6.1.4.1.868.2.5.106.1.2.2.1.2
The EVC or ECE index.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..11111  

tnEvcExtStatPort 1.3.6.1.4.1.868.2.5.106.1.2.2.1.3
The EVC or ECE index.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..11111  

tnEvcExtStatGreenFrameRx 1.3.6.1.4.1.868.2.5.106.1.2.2.1.4
The number Frames of green received.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

tnEvcExtStatGreenFrameTx 1.3.6.1.4.1.868.2.5.106.1.2.2.1.5
The number Frames of green transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

tnEvcExtStatGreenBytesRx 1.3.6.1.4.1.868.2.5.106.1.2.2.1.6
The number Bytes of green received.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

tnEvcExtStatGreenBytesTx 1.3.6.1.4.1.868.2.5.106.1.2.2.1.7
The number Bytes of green transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

tnEvcExtStatYellowFrameRx 1.3.6.1.4.1.868.2.5.106.1.2.2.1.8
The number Frames of yellow received.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

tnEvcExtStatYellowFrameTx 1.3.6.1.4.1.868.2.5.106.1.2.2.1.9
The number Frames of yellow transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

tnEvcExtStatYellowBytesRx 1.3.6.1.4.1.868.2.5.106.1.2.2.1.10
The number Bytes of yellow received.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

tnEvcExtStatYellowBytesTx 1.3.6.1.4.1.868.2.5.106.1.2.2.1.11
The number Bytes of yellow transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

tnEvcExtStatRedFrameRx 1.3.6.1.4.1.868.2.5.106.1.2.2.1.12
The number Frames of red received.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

tnEvcExtStatRedBytesRx 1.3.6.1.4.1.868.2.5.106.1.2.2.1.13
The number Bytes of red received.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

tnEvcExtStatDiscardFrameRx 1.3.6.1.4.1.868.2.5.106.1.2.2.1.14
The number Frames of discarded received.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

tnEvcExtStatDiscardFrameTx 1.3.6.1.4.1.868.2.5.106.1.2.2.1.15
The number Frames of discarded transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

tnEvcExtStatDiscardBytesRx 1.3.6.1.4.1.868.2.5.106.1.2.2.1.16
The number Bytes of discarded received.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

tnEvcExtStatDiscardBytesTx 1.3.6.1.4.1.868.2.5.106.1.2.2.1.17
The number Bytes of discarded transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

tnEvcExtStatclear 1.3.6.1.4.1.868.2.5.106.1.2.2.1.18
Clear the value by EVC or ECE index.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

tnEvcL2cpCfgTable 1.3.6.1.4.1.868.2.5.106.1.3.3
This table supports L2CP settings.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TnEvcL2cpCfgEntry

tnEvcL2cpCfgEntry 1.3.6.1.4.1.868.2.5.106.1.3.3.1
L2CP settings table entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  TnEvcL2cpCfgEntry  

tnEvcL2cpCfgInterfaceNumber 1.3.6.1.4.1.868.2.5.106.1.3.3.1.1
Sets L2CP interface number.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

tnEvcL2cpCfgIndex 1.3.6.1.4.1.868.2.5.106.1.3.3.1.2
Sets L2CP index number on an interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

tnEvcL2cpCfgType 1.3.6.1.4.1.868.2.5.106.1.3.3.1.3
Sets L2CP type setting.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER discard(1), tunnel(2), peer(3), passToEvc(4), peerToEvc(5)  

tnEvcL2cpCfgMatchScope 1.3.6.1.4.1.868.2.5.106.1.3.3.1.4
Sets L2CP selection matching scope.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER destinationAddressOnly(1), daPlusProtocol(2), daPlusProtocolPlusSubtype(3)  

tnEvcL2cpCfgMacAddress 1.3.6.1.4.1.868.2.5.106.1.3.3.1.5
Sets L2CP Destination MAC address.
Status: current Access: read-create
OBJECT-TYPE    
  MacAddress  

tnEvcL2cpCfgProtocol 1.3.6.1.4.1.868.2.5.106.1.3.3.1.6
Sets L2CP protocol.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

tnEvcL2cpCfgSubType 1.3.6.1.4.1.868.2.5.106.1.3.3.1.7
Sets L2CP subtype for the protocol selected.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

tnEvcL2cpCfgEvcName 1.3.6.1.4.1.868.2.5.106.1.3.3.1.8
Sets L2CP EVC association.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..45)  

tnEvcL2cpCfgValid 1.3.6.1.4.1.868.2.5.106.1.3.3.1.9
Sets L2CP valid instance.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER invalid(1), valid(2)  

tnEvcL2cpCfgRowStatus 1.3.6.1.4.1.868.2.5.106.1.3.3.1.10
The status of the row. The writable columns in a row cannot be changed if the row is active. All columns must have a valid value before a row can be activated.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

tnEvcConformance 1.3.6.1.4.1.868.2.5.106.1.8
OBJECT IDENTIFIER    

tnEvcGroups 1.3.6.1.4.1.868.2.5.106.1.8.1
OBJECT IDENTIFIER    

tnEvcPortConfigGroup 1.3.6.1.4.1.868.2.5.106.1.8.1.1
The collection of objects which are used to configure or describe the configuration or behavior of the S3280.
Status: current Access: read-create
OBJECT-GROUP    

tnEvcJaguarPortConfigGroup 1.3.6.1.4.1.868.2.5.106.1.8.1.2
The collection of objects which are used to configure or describe the configuration or behavior of the S4140.
Status: current Access: read-create
OBJECT-GROUP    

tnEvcTableGroup 1.3.6.1.4.1.868.2.5.106.1.8.1.3
The collection of objects which are used to configure or describe the configuration or behavior of the S4140.
Status: current Access: read-create
OBJECT-GROUP