TELDAT-TRAP-SRT-MIB

File: TELDAT-TRAP-SRT-MIB.mib (183471 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC TELDAT-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE OBJECT-IDENTITY
NOTIFICATION-TYPE Integer32 IpAddress
DisplayString telEventTraps

Defined Values

srtTrapsMIB 1.3.6.1.4.1.2007.1.4.72
This Module Information Base file is defined for managing received SNMP notifications generated by the SRT event subsystem.
MODULE-IDENTITY    

srtEventsGroup 1.3.6.1.4.1.2007.1.4.72.1
OBJECT IDENTIFIER    

srtNotifications 1.3.6.1.4.1.2007.1.4.72.2
OBJECT IDENTIFIER    

srtNotificationsPrefix 1.3.6.1.4.1.2007.1.4.72.2.0
OBJECT IDENTIFIER    

srtEventObjects1 1.3.6.1.4.1.2007.1.4.72.1.1
Event SRT.1 No buffer available to copy a frame in order to send a bridged frame on multiple interfaces. Bridged packets are sent on multiple interfaces either for multicast destination addresses, or in the case of certain static entries. No copy of this frame will be sent on the specified port and interface.
Status: current Access: read-write
OBJECT-IDENTITY    

srt1-source-mac 1.3.6.1.4.1.2007.1.4.72.1.1.1
Parameter 'source-mac' in event SRT.1
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt1-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.1.2
Parameter 'dest-mac' in event SRT.1
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt1-port 1.3.6.1.4.1.2007.1.4.72.1.1.3
Parameter 'port' in event SRT.1
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt1-interface 1.3.6.1.4.1.2007.1.4.72.1.1.4
Parameter 'interface' in event SRT.1
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt1-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.1.5
Parameter 'circuit-name' in event SRT.1
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects2 1.3.6.1.4.1.2007.1.4.72.1.2
Event SRT.2 The Spanning Tree Protocol requested setting this network into Learning state, but the command to the device failed. The error-code is a device-specific error code that may indicate what the error is.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt2-error-code 1.3.6.1.4.1.2007.1.4.72.1.2.1
Parameter 'error-code' in event SRT.2
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt2-interface 1.3.6.1.4.1.2007.1.4.72.1.2.2
Parameter 'interface' in event SRT.2
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt2-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.2.3
Parameter 'circuit-name' in event SRT.2
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects3 1.3.6.1.4.1.2007.1.4.72.1.3
Event SRT.3 An attempt to add a set of static entries to the internal database of a bridging interface having internal filtering failed. The error-code is a device-specific error code that may indicate what the error is.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt3-error-code 1.3.6.1.4.1.2007.1.4.72.1.3.1
Parameter 'error-code' in event SRT.3
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt3-interface 1.3.6.1.4.1.2007.1.4.72.1.3.2
Parameter 'interface' in event SRT.3
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt3-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.3.3
Parameter 'circuit-name' in event SRT.3
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects4 1.3.6.1.4.1.2007.1.4.72.1.4
Event SRT.4 No buffer was available to send a command to the device. The possible command names are 'D-CNFGSRB' (configure source-routing bridging), 'SRT-ON' (promiscuous on), 'SRT-INFORM' (learn capabilities of device), 'SRT-SET-AGE' (set age for filtering database in device), 'SRT-DECR-AGE' (do ageing pass on filtering database in device), 'SRT-ADD-ENTRY' (add static entry), 'SRT-DEL-ENTRY' (delete entry, from console), 'SRT-SEARCH-ENTRY' (search for particular entry, from console) and 'SRT-LIST-ENTRY' (list contents of learning database in card). For commands 'D-CNFGSRB' and 'SRT-ON' the result will be that the interface may remain in the wrong state. A failure on 'SRT-INFORM' could cause serious problems. For other commands the results will be less serious.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt4-command-name 1.3.6.1.4.1.2007.1.4.72.1.4.1
Parameter 'command-name' in event SRT.4
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt4-interface 1.3.6.1.4.1.2007.1.4.72.1.4.2
Parameter 'interface' in event SRT.4
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects5 1.3.6.1.4.1.2007.1.4.72.1.5
Event SRT.5 The sending of a packet being forwarded failed. The reason is the internal error code for the failure.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt5-source-mac 1.3.6.1.4.1.2007.1.4.72.1.5.1
Parameter 'source-mac' in event SRT.5
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt5-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.5.2
Parameter 'dest-mac' in event SRT.5
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt5-reason-code 1.3.6.1.4.1.2007.1.4.72.1.5.3
Parameter 'reason-code' in event SRT.5
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt5-port 1.3.6.1.4.1.2007.1.4.72.1.5.4
Parameter 'port' in event SRT.5
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt5-interface-name 1.3.6.1.4.1.2007.1.4.72.1.5.5
Parameter 'interface-name' in event SRT.5
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt5-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.5.6
Parameter 'circuit-name' in event SRT.5
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects6 1.3.6.1.4.1.2007.1.4.72.1.6
Event SRT.6 The input queue for frames to be forwarded is too long, and this frame has been dropped to attempt to alleviate the congestion.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt6-source-mac 1.3.6.1.4.1.2007.1.4.72.1.6.1
Parameter 'source-mac' in event SRT.6
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt6-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.6.2
Parameter 'dest-mac' in event SRT.6
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt6-interface 1.3.6.1.4.1.2007.1.4.72.1.6.3
Parameter 'interface' in event SRT.6
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt6-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.6.4
Parameter 'circuit-name' in event SRT.6
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects7 1.3.6.1.4.1.2007.1.4.72.1.7
Event SRT.7 The input queue for Spanning Tree Protocol Bridge Protocl Data Units is too long, and this frame has been dropped to attempt to alleviate the congestion.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt7-source-mac 1.3.6.1.4.1.2007.1.4.72.1.7.1
Parameter 'source-mac' in event SRT.7
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt7-interface 1.3.6.1.4.1.2007.1.4.72.1.7.2
Parameter 'interface' in event SRT.7
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt7-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.7.3
Parameter 'circuit-name' in event SRT.7
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects8 1.3.6.1.4.1.2007.1.4.72.1.8
Event SRT.8 The specified frame is too large to send on this outgoing port and interface. The reformatted-length is the size of the frame including MAC headers after any mapping of data link headers.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt8-source-mac 1.3.6.1.4.1.2007.1.4.72.1.8.1
Parameter 'source-mac' in event SRT.8
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt8-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.8.2
Parameter 'dest-mac' in event SRT.8
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt8-reformatted-length 1.3.6.1.4.1.2007.1.4.72.1.8.3
Parameter 'reformatted-length' in event SRT.8
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt8-output-maximum 1.3.6.1.4.1.2007.1.4.72.1.8.4
Parameter 'output-maximum' in event SRT.8
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt8-port 1.3.6.1.4.1.2007.1.4.72.1.8.5
Parameter 'port' in event SRT.8
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt8-interface 1.3.6.1.4.1.2007.1.4.72.1.8.6
Parameter 'interface' in event SRT.8
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt8-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.8.7
Parameter 'circuit-name' in event SRT.8
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects9 1.3.6.1.4.1.2007.1.4.72.1.9
Event SRT.9 A frame has been received for bridging on an interface that is down. It will be ignored.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt9-source-mac 1.3.6.1.4.1.2007.1.4.72.1.9.1
Parameter 'source-mac' in event SRT.9
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt9-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.9.2
Parameter 'dest-mac' in event SRT.9
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt9-interface 1.3.6.1.4.1.2007.1.4.72.1.9.3
Parameter 'interface' in event SRT.9
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects10 1.3.6.1.4.1.2007.1.4.72.1.10
Event SRT.10 A MAC frame has been received by the hardware, but is being dropped because the source MAC address is being administratively filtered by the bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt10-source-mac 1.3.6.1.4.1.2007.1.4.72.1.10.1
Parameter 'source-mac' in event SRT.10
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt10-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.10.2
Parameter 'dest-mac' in event SRT.10
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt10-port 1.3.6.1.4.1.2007.1.4.72.1.10.3
Parameter 'port' in event SRT.10
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt10-interface 1.3.6.1.4.1.2007.1.4.72.1.10.4
Parameter 'interface' in event SRT.10
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt10-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.10.5
Parameter 'circuit-name' in event SRT.10
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects11 1.3.6.1.4.1.2007.1.4.72.1.11
Event SRT.11 A MAC frame was received on a port that is still only in 'learning' state. Frames are only bridged when the input port is in 'forwarding' state. While the port is still in 'learning' state, they are only processed to learn the source addresses for the filtering database. The frame will not be bridged.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt11-source-mac 1.3.6.1.4.1.2007.1.4.72.1.11.1
Parameter 'source-mac' in event SRT.11
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt11-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.11.2
Parameter 'dest-mac' in event SRT.11
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt11-port 1.3.6.1.4.1.2007.1.4.72.1.11.3
Parameter 'port' in event SRT.11
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt11-interface 1.3.6.1.4.1.2007.1.4.72.1.11.4
Parameter 'interface' in event SRT.11
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt11-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.11.5
Parameter 'circuit-name' in event SRT.11
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects12 1.3.6.1.4.1.2007.1.4.72.1.12
Event SRT.12 A MAC frame was being bridged, but the destination port was not in 'forwarding' state. It will not be sent on that port.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt12-source-mac 1.3.6.1.4.1.2007.1.4.72.1.12.1
Parameter 'source-mac' in event SRT.12
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt12-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.12.2
Parameter 'dest-mac' in event SRT.12
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt12-port 1.3.6.1.4.1.2007.1.4.72.1.12.3
Parameter 'port' in event SRT.12
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt12-interface 1.3.6.1.4.1.2007.1.4.72.1.12.4
Parameter 'interface' in event SRT.12
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt12-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.12.5
Parameter 'circuit-name' in event SRT.12
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects13 1.3.6.1.4.1.2007.1.4.72.1.13
Event SRT.13 A MAC frame has been received whose destination address is known to be on the same side of the bridge as the packet came from. It is dropped by the filtering logic since it does not need to be bridged.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt13-source-mac 1.3.6.1.4.1.2007.1.4.72.1.13.1
Parameter 'source-mac' in event SRT.13
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt13-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.13.2
Parameter 'dest-mac' in event SRT.13
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt13-port 1.3.6.1.4.1.2007.1.4.72.1.13.3
Parameter 'port' in event SRT.13
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt13-interface 1.3.6.1.4.1.2007.1.4.72.1.13.4
Parameter 'interface' in event SRT.13
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt13-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.13.5
Parameter 'circuit-name' in event SRT.13
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects14 1.3.6.1.4.1.2007.1.4.72.1.14
Event SRT.14 A frame being bridged was destined for a port which is not running transparent bridging, or not in 'forwarding' state for transparent bridging.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt14-source-mac 1.3.6.1.4.1.2007.1.4.72.1.14.1
Parameter 'source-mac' in event SRT.14
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt14-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.14.2
Parameter 'dest-mac' in event SRT.14
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt14-port 1.3.6.1.4.1.2007.1.4.72.1.14.3
Parameter 'port' in event SRT.14
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt14-interface 1.3.6.1.4.1.2007.1.4.72.1.14.4
Parameter 'interface' in event SRT.14
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt14-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.14.5
Parameter 'circuit-name' in event SRT.14
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects15 1.3.6.1.4.1.2007.1.4.72.1.15
Event SRT.15 A frame is being bridged between these two interfaces. The destination address was known, so it was sent only to the correct destination network.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt15-source-mac 1.3.6.1.4.1.2007.1.4.72.1.15.1
Parameter 'source-mac' in event SRT.15
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt15-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.15.2
Parameter 'dest-mac' in event SRT.15
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt15-port 1.3.6.1.4.1.2007.1.4.72.1.15.3
Parameter 'port' in event SRT.15
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt15-interface 1.3.6.1.4.1.2007.1.4.72.1.15.4
Parameter 'interface' in event SRT.15
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt15-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.15.5
Parameter 'circuit-name' in event SRT.15
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt15-out-port 1.3.6.1.4.1.2007.1.4.72.1.15.6
Parameter 'out-port' in event SRT.15
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt15-out-interface 1.3.6.1.4.1.2007.1.4.72.1.15.7
Parameter 'out-interface' in event SRT.15
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt15-out-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.15.8
Parameter 'out-circuit-name' in event SRT.15
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects16 1.3.6.1.4.1.2007.1.4.72.1.16
Event SRT.16 A frame is being transparently bridged to all active transparent bridging ports. This happens when the frame destination is a multicast, when the frame destination is not in the learning database, or when required by static entries in the learning database. There will be one message for each port the frame is sent on.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt16-source-mac 1.3.6.1.4.1.2007.1.4.72.1.16.1
Parameter 'source-mac' in event SRT.16
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt16-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.16.2
Parameter 'dest-mac' in event SRT.16
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt16-port 1.3.6.1.4.1.2007.1.4.72.1.16.3
Parameter 'port' in event SRT.16
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt16-interface 1.3.6.1.4.1.2007.1.4.72.1.16.4
Parameter 'interface' in event SRT.16
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt16-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.16.5
Parameter 'circuit-name' in event SRT.16
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt16-out-port 1.3.6.1.4.1.2007.1.4.72.1.16.6
Parameter 'out-port' in event SRT.16
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt16-out-interface 1.3.6.1.4.1.2007.1.4.72.1.16.7
Parameter 'out-interface' in event SRT.16
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt16-out-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.16.8
Parameter 'out-circuit-name' in event SRT.16
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects17 1.3.6.1.4.1.2007.1.4.72.1.17
Event SRT.17 The SRT forwarder is starting the process of enabling bridging on the specified interface. This starts when the interface comes up from a self-test.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt17-port 1.3.6.1.4.1.2007.1.4.72.1.17.1
Parameter 'port' in event SRT.17
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt17-interface 1.3.6.1.4.1.2007.1.4.72.1.17.2
Parameter 'interface' in event SRT.17
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt17-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.17.3
Parameter 'circuit-name' in event SRT.17
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects18 1.3.6.1.4.1.2007.1.4.72.1.18
Event SRT.18 The SRT forwarder has completed the process of enabling bridging on the specified interface. It will now enter 'blocking' state.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt18-port 1.3.6.1.4.1.2007.1.4.72.1.18.1
Parameter 'port' in event SRT.18
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt18-interface 1.3.6.1.4.1.2007.1.4.72.1.18.2
Parameter 'interface' in event SRT.18
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt18-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.18.3
Parameter 'circuit-name' in event SRT.18
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects19 1.3.6.1.4.1.2007.1.4.72.1.19
Event SRT.19 The SRT forwarder had been enabled on a type of interface it does not support.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt19-interface-name 1.3.6.1.4.1.2007.1.4.72.1.19.1
Parameter 'interface-name' in event SRT.19
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects20 1.3.6.1.4.1.2007.1.4.72.1.20
Event SRT.20 The user has configured the bridge to autoconfigure the bridge address based on the MAC address of the lowest number port. However, the lowest numbered port is of a type that does not have a MAC address, such as a serial line.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt20-port 1.3.6.1.4.1.2007.1.4.72.1.20.1
Parameter 'port' in event SRT.20
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt20-interface 1.3.6.1.4.1.2007.1.4.72.1.20.2
Parameter 'interface' in event SRT.20
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt20-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.20.3
Parameter 'circuit-name' in event SRT.20
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects21 1.3.6.1.4.1.2007.1.4.72.1.21
Event SRT.21 Bridge frame received, but there is no bridging available in this load. The frame will be ignored.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt21-source-mac 1.3.6.1.4.1.2007.1.4.72.1.21.1
Parameter 'source-mac' in event SRT.21
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt21-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.21.2
Parameter 'dest-mac' in event SRT.21
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt21-interface 1.3.6.1.4.1.2007.1.4.72.1.21.3
Parameter 'interface' in event SRT.21
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects23 1.3.6.1.4.1.2007.1.4.72.1.23
Event SRT.23 The port has been configured to use an interface that has not been configured with the Config> ADD DEVICE command. This port of the bridge will be disabled.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt23-port 1.3.6.1.4.1.2007.1.4.72.1.23.1
Parameter 'port' in event SRT.23
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt23-interface-number 1.3.6.1.4.1.2007.1.4.72.1.23.2
Parameter 'interface-number' in event SRT.23
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srtEventObjects24 1.3.6.1.4.1.2007.1.4.72.1.24
Event SRT.24 Less than two (valid) ports have been configured on the bridge. There must be at least two ports.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt24-existent-port-count 1.3.6.1.4.1.2007.1.4.72.1.24.1
Parameter 'existent-port-count' in event SRT.24
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srtEventObjects25 1.3.6.1.4.1.2007.1.4.72.1.25
Event SRT.25 There is not enough free memory to allocate even a minimal size filtering database. The bridge will be disabled. The bridge starts by trying to allocate requested-size bytes, and then tries with progressively smaller sizes down to minimum-size. The minimum size is enough only for the registered and static entries.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt25-requested-size 1.3.6.1.4.1.2007.1.4.72.1.25.1
Parameter 'requested-size' in event SRT.25
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt25-minimum-size 1.3.6.1.4.1.2007.1.4.72.1.25.2
Parameter 'minimum-size' in event SRT.25
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srtEventObjects26 1.3.6.1.4.1.2007.1.4.72.1.26
Event SRT.26 Frames to and from the same address are not bridged by this bridge.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt26-source-mac 1.3.6.1.4.1.2007.1.4.72.1.26.1
Parameter 'source-mac' in event SRT.26
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt26-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.26.2
Parameter 'dest-mac' in event SRT.26
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt26-port 1.3.6.1.4.1.2007.1.4.72.1.26.3
Parameter 'port' in event SRT.26
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt26-interface 1.3.6.1.4.1.2007.1.4.72.1.26.4
Parameter 'interface' in event SRT.26
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt26-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.26.5
Parameter 'circuit-name' in event SRT.26
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects27 1.3.6.1.4.1.2007.1.4.72.1.27
Event SRT.27 The Spanning Tree Protocol has requested this state change for this port in the SRT bridge. The old-state and new-state are one of: FORWARDING (Spanning Tree Protocol Forwarding state), LEARNING (Spanning Tree Protocol Learning state), LISTENING (Spanning Tree Protocol Listening state), BLOCKED (Spanning Tree Protocol Blocking state), CONFIGURING (configuration of port device pending), POSTCONFIGURING (configuration of port device done), PRECONFIGURING (port enabled, configuration of port device to start) and DISABLED (port disabled).
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt27-old-state 1.3.6.1.4.1.2007.1.4.72.1.27.1
Parameter 'old-state' in event SRT.27
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt27-new-state 1.3.6.1.4.1.2007.1.4.72.1.27.2
Parameter 'new-state' in event SRT.27
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt27-port 1.3.6.1.4.1.2007.1.4.72.1.27.3
Parameter 'port' in event SRT.27
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt27-interface 1.3.6.1.4.1.2007.1.4.72.1.27.4
Parameter 'interface' in event SRT.27
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt27-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.27.5
Parameter 'circuit-name' in event SRT.27
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects28 1.3.6.1.4.1.2007.1.4.72.1.28
Event SRT.28 There is no room for the permanent entry in the filtering database. The bridge will be disabled.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt28-mac-address 1.3.6.1.4.1.2007.1.4.72.1.28.1
Parameter 'mac-address' in event SRT.28
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects29 1.3.6.1.4.1.2007.1.4.72.1.29
Event SRT.29 There is no room for the permanent entry in an auxiliary database. The bridge will be disabled.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt29-mac-address 1.3.6.1.4.1.2007.1.4.72.1.29.1
Parameter 'mac-address' in event SRT.29
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects30 1.3.6.1.4.1.2007.1.4.72.1.30
Event SRT.30 A command to a network device failed. The possible command names are 'SRT-ON' (promiscuous on), 'SRT-OFF' (promiscuous off), 'SRT-INFORM' (learn capabilities of device), 'SRT-ADD-ENTRY' (add static entry in device), 'SRT-SET-AGE' (set age for filtering database in device) and 'SRT-DECR-AGE' (do ageing pass on filtering database in device). For commands 'SRT-ON' and 'SRT-OFF' the result will be that the interface may remain in the worong state. A failure on 'SRT-INFORM' could cause serious problems. For other commands the results will be less serious.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt30-command 1.3.6.1.4.1.2007.1.4.72.1.30.1
Parameter 'command' in event SRT.30
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt30-interface 1.3.6.1.4.1.2007.1.4.72.1.30.2
Parameter 'interface' in event SRT.30
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects31 1.3.6.1.4.1.2007.1.4.72.1.31
Event SRT.31 No buffer available to copy a frame in order to send an All Routes Explorer (ARE) or Spanning Tree Explorer (STE) routing-type frame on multiple interfaces. ARE frames are sent on all interfaces which are part of the SRT spanning tree, STE frames are sent on all interfaces running source-routing. No copy of this frame will be sent on the specified port and interface.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt31-routing-type 1.3.6.1.4.1.2007.1.4.72.1.31.1
Parameter 'routing-type' in event SRT.31
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt31-source-mac 1.3.6.1.4.1.2007.1.4.72.1.31.2
Parameter 'source-mac' in event SRT.31
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt31-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.31.3
Parameter 'dest-mac' in event SRT.31
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt31-port 1.3.6.1.4.1.2007.1.4.72.1.31.4
Parameter 'port' in event SRT.31
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt31-interface 1.3.6.1.4.1.2007.1.4.72.1.31.5
Parameter 'interface' in event SRT.31
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt31-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.31.6
Parameter 'circuit-name' in event SRT.31
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects32 1.3.6.1.4.1.2007.1.4.72.1.32
Event SRT.32 The sending of a source routed frame being forwarded failed. The reason-code is the internal error code for the failure.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt32-source-mac 1.3.6.1.4.1.2007.1.4.72.1.32.1
Parameter 'source-mac' in event SRT.32
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt32-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.32.2
Parameter 'dest-mac' in event SRT.32
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt32-reason-code 1.3.6.1.4.1.2007.1.4.72.1.32.3
Parameter 'reason-code' in event SRT.32
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt32-port 1.3.6.1.4.1.2007.1.4.72.1.32.4
Parameter 'port' in event SRT.32
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt32-interface-name 1.3.6.1.4.1.2007.1.4.72.1.32.5
Parameter 'interface-name' in event SRT.32
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt32-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.32.6
Parameter 'circuit-name' in event SRT.32
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects33 1.3.6.1.4.1.2007.1.4.72.1.33
Event SRT.33 A source-routed frame having a All Routes Descriptor (ARE) or Spanning Tree Explorer (STE) routing-type in the RIF has a duplicate Routing Descriptor in the RIF. The frame will be dropped. This is a normal occurrence for ARE frames when there are any duplicate paths in the source routing domain. For STE frames, this indicates that there is an interface that is part of the source-routing spanning tree that should not be.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt33-routing-type 1.3.6.1.4.1.2007.1.4.72.1.33.1
Parameter 'routing-type' in event SRT.33
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt33-source-mac 1.3.6.1.4.1.2007.1.4.72.1.33.2
Parameter 'source-mac' in event SRT.33
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt33-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.33.3
Parameter 'dest-mac' in event SRT.33
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt33-port 1.3.6.1.4.1.2007.1.4.72.1.33.4
Parameter 'port' in event SRT.33
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt33-interface 1.3.6.1.4.1.2007.1.4.72.1.33.5
Parameter 'interface' in event SRT.33
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt33-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.33.6
Parameter 'circuit-name' in event SRT.33
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects34 1.3.6.1.4.1.2007.1.4.72.1.34
Event SRT.34 A source-routed frame of Specifically-routed frame (SRF) type has a duplicate LOUT (outgoing LAN ID). This is illegal, and the frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt34-RIF 1.3.6.1.4.1.2007.1.4.72.1.34.1
Parameter 'RIF' in event SRT.34
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt34-source-mac 1.3.6.1.4.1.2007.1.4.72.1.34.2
Parameter 'source-mac' in event SRT.34
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt34-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.34.3
Parameter 'dest-mac' in event SRT.34
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt34-port 1.3.6.1.4.1.2007.1.4.72.1.34.4
Parameter 'port' in event SRT.34
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt34-interface 1.3.6.1.4.1.2007.1.4.72.1.34.5
Parameter 'interface' in event SRT.34
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt34-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.34.6
Parameter 'circuit-name' in event SRT.34
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects35 1.3.6.1.4.1.2007.1.4.72.1.35
Event SRT.35 An All Routes Explorer (ARE) source-routed frame has more Route Descriptors than this bridge is configured to allow for ARE frames. The frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt35-RIF 1.3.6.1.4.1.2007.1.4.72.1.35.1
Parameter 'RIF' in event SRT.35
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt35-source-mac 1.3.6.1.4.1.2007.1.4.72.1.35.2
Parameter 'source-mac' in event SRT.35
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt35-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.35.3
Parameter 'dest-mac' in event SRT.35
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt35-port 1.3.6.1.4.1.2007.1.4.72.1.35.4
Parameter 'port' in event SRT.35
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt35-interface 1.3.6.1.4.1.2007.1.4.72.1.35.5
Parameter 'interface' in event SRT.35
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt35-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.35.6
Parameter 'circuit-name' in event SRT.35
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects36 1.3.6.1.4.1.2007.1.4.72.1.36
Event SRT.36 A Spanning Tree Explorer (STE) source-routed frame has more Route Descriptors than this bridge is configured to allow for STE frames. The frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt36-RIF 1.3.6.1.4.1.2007.1.4.72.1.36.1
Parameter 'RIF' in event SRT.36
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt36-source-mac 1.3.6.1.4.1.2007.1.4.72.1.36.2
Parameter 'source-mac' in event SRT.36
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt36-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.36.3
Parameter 'dest-mac' in event SRT.36
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt36-port 1.3.6.1.4.1.2007.1.4.72.1.36.4
Parameter 'port' in event SRT.36
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt36-interface 1.3.6.1.4.1.2007.1.4.72.1.36.5
Parameter 'interface' in event SRT.36
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt36-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.36.6
Parameter 'circuit-name' in event SRT.36
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects37 1.3.6.1.4.1.2007.1.4.72.1.37
Event SRT.37 A source-routed frame of Specifically-routed frame (SRF) type has an outgoing LOUT (LAN ID Out) that does not match that of any active source-routing interface in the router. It will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt37-RIF 1.3.6.1.4.1.2007.1.4.72.1.37.1
Parameter 'RIF' in event SRT.37
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt37-source-mac 1.3.6.1.4.1.2007.1.4.72.1.37.2
Parameter 'source-mac' in event SRT.37
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt37-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.37.3
Parameter 'dest-mac' in event SRT.37
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt37-port 1.3.6.1.4.1.2007.1.4.72.1.37.4
Parameter 'port' in event SRT.37
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt37-interface 1.3.6.1.4.1.2007.1.4.72.1.37.5
Parameter 'interface' in event SRT.37
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects38 1.3.6.1.4.1.2007.1.4.72.1.38
Event SRT.38 An All Routes Explorer frame has been received on the specified port.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt38-RIF 1.3.6.1.4.1.2007.1.4.72.1.38.1
Parameter 'RIF' in event SRT.38
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt38-source-mac 1.3.6.1.4.1.2007.1.4.72.1.38.2
Parameter 'source-mac' in event SRT.38
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt38-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.38.3
Parameter 'dest-mac' in event SRT.38
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt38-port 1.3.6.1.4.1.2007.1.4.72.1.38.4
Parameter 'port' in event SRT.38
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt38-interface 1.3.6.1.4.1.2007.1.4.72.1.38.5
Parameter 'interface' in event SRT.38
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt38-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.38.6
Parameter 'circuit-name' in event SRT.38
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects39 1.3.6.1.4.1.2007.1.4.72.1.39
Event SRT.39 An All Routes Explorer frame has been sent on the specified port.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt39-RIF 1.3.6.1.4.1.2007.1.4.72.1.39.1
Parameter 'RIF' in event SRT.39
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt39-source-mac 1.3.6.1.4.1.2007.1.4.72.1.39.2
Parameter 'source-mac' in event SRT.39
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt39-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.39.3
Parameter 'dest-mac' in event SRT.39
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt39-port 1.3.6.1.4.1.2007.1.4.72.1.39.4
Parameter 'port' in event SRT.39
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt39-interface 1.3.6.1.4.1.2007.1.4.72.1.39.5
Parameter 'interface' in event SRT.39
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt39-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.39.6
Parameter 'circuit-name' in event SRT.39
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects40 1.3.6.1.4.1.2007.1.4.72.1.40
Event SRT.40 A Spanning Tree Explorer frame has been received on the specified port.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt40-RIF 1.3.6.1.4.1.2007.1.4.72.1.40.1
Parameter 'RIF' in event SRT.40
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt40-source-mac 1.3.6.1.4.1.2007.1.4.72.1.40.2
Parameter 'source-mac' in event SRT.40
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt40-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.40.3
Parameter 'dest-mac' in event SRT.40
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt40-port 1.3.6.1.4.1.2007.1.4.72.1.40.4
Parameter 'port' in event SRT.40
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt40-interface 1.3.6.1.4.1.2007.1.4.72.1.40.5
Parameter 'interface' in event SRT.40
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt40-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.40.6
Parameter 'circuit-name' in event SRT.40
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects41 1.3.6.1.4.1.2007.1.4.72.1.41
Event SRT.41 A Spanning Tree Explorer frame has been sent on the specified port.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt41-RIF 1.3.6.1.4.1.2007.1.4.72.1.41.1
Parameter 'RIF' in event SRT.41
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt41-source-mac 1.3.6.1.4.1.2007.1.4.72.1.41.2
Parameter 'source-mac' in event SRT.41
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt41-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.41.3
Parameter 'dest-mac' in event SRT.41
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt41-port 1.3.6.1.4.1.2007.1.4.72.1.41.4
Parameter 'port' in event SRT.41
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt41-interface 1.3.6.1.4.1.2007.1.4.72.1.41.5
Parameter 'interface' in event SRT.41
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt41-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.41.6
Parameter 'circuit-name' in event SRT.41
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects42 1.3.6.1.4.1.2007.1.4.72.1.42
Event SRT.42 A source-routing explorer (ARE or STE in routing-type) has had the Largest Frame (LF) field lowered in its RIF. This happens whenever a frame is received from a segment with a smaller maximum frame size than the one presently encoded in the LF bits. This is a normal part of the spanning tree protocol to determine the maximum frame size on all routes.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt42-routing-type 1.3.6.1.4.1.2007.1.4.72.1.42.1
Parameter 'routing-type' in event SRT.42
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt42-old-LF 1.3.6.1.4.1.2007.1.4.72.1.42.2
Parameter 'old-LF' in event SRT.42
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt42-new-LF 1.3.6.1.4.1.2007.1.4.72.1.42.3
Parameter 'new-LF' in event SRT.42
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt42-source-mac 1.3.6.1.4.1.2007.1.4.72.1.42.4
Parameter 'source-mac' in event SRT.42
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt42-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.42.5
Parameter 'dest-mac' in event SRT.42
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt42-port 1.3.6.1.4.1.2007.1.4.72.1.42.6
Parameter 'port' in event SRT.42
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt42-interface 1.3.6.1.4.1.2007.1.4.72.1.42.7
Parameter 'interface' in event SRT.42
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt42-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.42.8
Parameter 'circuit-name' in event SRT.42
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects43 1.3.6.1.4.1.2007.1.4.72.1.43
Event SRT.43 A source-routing explorer (ARE or STE in routing-type) has had the Largest Frame (LF) field lowered in its RIF. This happens whenever a frame is sent to a segment with a smaller maximum frame size than the one presently encoded in the LF bits. This is a normal part of the spanning tree protocol to determine the maximum frame size on all routes.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt43-routing-type 1.3.6.1.4.1.2007.1.4.72.1.43.1
Parameter 'routing-type' in event SRT.43
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt43-old-LF 1.3.6.1.4.1.2007.1.4.72.1.43.2
Parameter 'old-LF' in event SRT.43
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt43-new-LF 1.3.6.1.4.1.2007.1.4.72.1.43.3
Parameter 'new-LF' in event SRT.43
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt43-source-mac 1.3.6.1.4.1.2007.1.4.72.1.43.4
Parameter 'source-mac' in event SRT.43
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt43-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.43.5
Parameter 'dest-mac' in event SRT.43
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt43-port 1.3.6.1.4.1.2007.1.4.72.1.43.6
Parameter 'port' in event SRT.43
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt43-interface 1.3.6.1.4.1.2007.1.4.72.1.43.7
Parameter 'interface' in event SRT.43
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt43-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.43.8
Parameter 'circuit-name' in event SRT.43
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects44 1.3.6.1.4.1.2007.1.4.72.1.44
Event SRT.44 A Specifically-routed frame has been received on the specified port.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt44-RIF 1.3.6.1.4.1.2007.1.4.72.1.44.1
Parameter 'RIF' in event SRT.44
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt44-source-mac 1.3.6.1.4.1.2007.1.4.72.1.44.2
Parameter 'source-mac' in event SRT.44
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt44-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.44.3
Parameter 'dest-mac' in event SRT.44
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt44-port 1.3.6.1.4.1.2007.1.4.72.1.44.4
Parameter 'port' in event SRT.44
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt44-interface 1.3.6.1.4.1.2007.1.4.72.1.44.5
Parameter 'interface' in event SRT.44
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt44-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.44.6
Parameter 'circuit-name' in event SRT.44
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects45 1.3.6.1.4.1.2007.1.4.72.1.45
Event SRT.45 A Specifically-routed frame is being sent on the specified port.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt45-RIF 1.3.6.1.4.1.2007.1.4.72.1.45.1
Parameter 'RIF' in event SRT.45
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt45-source-mac 1.3.6.1.4.1.2007.1.4.72.1.45.2
Parameter 'source-mac' in event SRT.45
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt45-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.45.3
Parameter 'dest-mac' in event SRT.45
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt45-port 1.3.6.1.4.1.2007.1.4.72.1.45.4
Parameter 'port' in event SRT.45
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt45-interface 1.3.6.1.4.1.2007.1.4.72.1.45.5
Parameter 'interface' in event SRT.45
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt45-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.45.6
Parameter 'circuit-name' in event SRT.45
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects46 1.3.6.1.4.1.2007.1.4.72.1.46
Event SRT.46 A source-routed frame has been received on the specified port, but that port is not configured for bridging. The routing-type is one of SRF (Specifically-routed frame), STE (Spanning Tree Expolorer) or ARE (All Routes Explorer). This really should not happen on more than a transient basis, because ports that are not enabled for bridging should not be queueing packets to the source-routing forwarder.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt46-routing-type 1.3.6.1.4.1.2007.1.4.72.1.46.1
Parameter 'routing-type' in event SRT.46
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt46-source-mac 1.3.6.1.4.1.2007.1.4.72.1.46.2
Parameter 'source-mac' in event SRT.46
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt46-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.46.3
Parameter 'dest-mac' in event SRT.46
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt46-port 1.3.6.1.4.1.2007.1.4.72.1.46.4
Parameter 'port' in event SRT.46
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt46-interface 1.3.6.1.4.1.2007.1.4.72.1.46.5
Parameter 'interface' in event SRT.46
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt46-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.46.6
Parameter 'circuit-name' in event SRT.46
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects47 1.3.6.1.4.1.2007.1.4.72.1.47
Event SRT.47 A source-routed frame has been received on the specified port, but that port is not configured for source-routing bridging. The routing-type is one of SRF (Specifically-routed frame), STE (Spanning Tree Expolorer) or ARE (All Routes Explorer). This really should not happen on more than a transient basis, because ports that are not enabled for bridging should not be queueing packets to the source-routing forwarder.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt47-routing-type 1.3.6.1.4.1.2007.1.4.72.1.47.1
Parameter 'routing-type' in event SRT.47
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt47-source-mac 1.3.6.1.4.1.2007.1.4.72.1.47.2
Parameter 'source-mac' in event SRT.47
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt47-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.47.3
Parameter 'dest-mac' in event SRT.47
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt47-port 1.3.6.1.4.1.2007.1.4.72.1.47.4
Parameter 'port' in event SRT.47
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt47-interface 1.3.6.1.4.1.2007.1.4.72.1.47.5
Parameter 'interface' in event SRT.47
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt47-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.47.6
Parameter 'circuit-name' in event SRT.47
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects48 1.3.6.1.4.1.2007.1.4.72.1.48
Event SRT.48 A Spanning Tree Explorer (STE) frame was dropped, and not forwarded, because the incoming port is not part of the spanning tree, or has been configured not to forward STE frames.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt48-RIF 1.3.6.1.4.1.2007.1.4.72.1.48.1
Parameter 'RIF' in event SRT.48
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt48-source-mac 1.3.6.1.4.1.2007.1.4.72.1.48.2
Parameter 'source-mac' in event SRT.48
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt48-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.48.3
Parameter 'dest-mac' in event SRT.48
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt48-port 1.3.6.1.4.1.2007.1.4.72.1.48.4
Parameter 'port' in event SRT.48
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt48-interface 1.3.6.1.4.1.2007.1.4.72.1.48.5
Parameter 'interface' in event SRT.48
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt48-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.48.6
Parameter 'circuit-name' in event SRT.48
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects49 1.3.6.1.4.1.2007.1.4.72.1.49
Event SRT.49 A Spanning Tree Explorer (STE) frame was not sent on the specified port because it is not part of the spanning tree, or has been configured not to forward STE frames.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt49-RIF 1.3.6.1.4.1.2007.1.4.72.1.49.1
Parameter 'RIF' in event SRT.49
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt49-source-mac 1.3.6.1.4.1.2007.1.4.72.1.49.2
Parameter 'source-mac' in event SRT.49
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt49-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.49.3
Parameter 'dest-mac' in event SRT.49
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt49-port 1.3.6.1.4.1.2007.1.4.72.1.49.4
Parameter 'port' in event SRT.49
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt49-interface 1.3.6.1.4.1.2007.1.4.72.1.49.5
Parameter 'interface' in event SRT.49
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt49-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.49.6
Parameter 'circuit-name' in event SRT.49
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects50 1.3.6.1.4.1.2007.1.4.72.1.50
Event SRT.50 The bridge tried to enable source-routing bridging on this interface, but the interface refused the configuration command. Source-routing will be left disabled on this interface.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt50-error-string 1.3.6.1.4.1.2007.1.4.72.1.50.1
Parameter 'error-string' in event SRT.50
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt50-interface 1.3.6.1.4.1.2007.1.4.72.1.50.2
Parameter 'interface' in event SRT.50
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects51 1.3.6.1.4.1.2007.1.4.72.1.51
Event SRT.51 The specified Specifically-routed (source-routed) frame is too large to send on this outgoing port and interface. The reformatted-length is the size of the frame including MAC headers after any mapping of data link headers.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt51-source-mac 1.3.6.1.4.1.2007.1.4.72.1.51.1
Parameter 'source-mac' in event SRT.51
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt51-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.51.2
Parameter 'dest-mac' in event SRT.51
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt51-reformatted-length 1.3.6.1.4.1.2007.1.4.72.1.51.3
Parameter 'reformatted-length' in event SRT.51
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt51-output-maximum 1.3.6.1.4.1.2007.1.4.72.1.51.4
Parameter 'output-maximum' in event SRT.51
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt51-port 1.3.6.1.4.1.2007.1.4.72.1.51.5
Parameter 'port' in event SRT.51
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt51-interface 1.3.6.1.4.1.2007.1.4.72.1.51.6
Parameter 'interface' in event SRT.51
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt51-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.51.7
Parameter 'circuit-name' in event SRT.51
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects52 1.3.6.1.4.1.2007.1.4.72.1.52
Event SRT.52 The source-routed explorer (ARE or STE routing-type) frame is too large to send on this outgoing port and interface. The reformatted-length is the size of the frame including MAC headers after any mapping of data link headers.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt52-routing-type 1.3.6.1.4.1.2007.1.4.72.1.52.1
Parameter 'routing-type' in event SRT.52
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt52-source-mac 1.3.6.1.4.1.2007.1.4.72.1.52.2
Parameter 'source-mac' in event SRT.52
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt52-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.52.3
Parameter 'dest-mac' in event SRT.52
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt52-reformatted-length 1.3.6.1.4.1.2007.1.4.72.1.52.4
Parameter 'reformatted-length' in event SRT.52
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt52-output-maximum 1.3.6.1.4.1.2007.1.4.72.1.52.5
Parameter 'output-maximum' in event SRT.52
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt52-port 1.3.6.1.4.1.2007.1.4.72.1.52.6
Parameter 'port' in event SRT.52
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt52-interface 1.3.6.1.4.1.2007.1.4.72.1.52.7
Parameter 'interface' in event SRT.52
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt52-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.52.8
Parameter 'circuit-name' in event SRT.52
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects53 1.3.6.1.4.1.2007.1.4.72.1.53
Event SRT.53 A source-routing frame was received with an invalid RIF length encoded in the Length bits of the RIF. The routing-type is one of SRF (Specifically-routed frame), STE (Spanning Tree Expolorer) or ARE (All Routes Explorer).
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt53-routing-type 1.3.6.1.4.1.2007.1.4.72.1.53.1
Parameter 'routing-type' in event SRT.53
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt53-RIF-length 1.3.6.1.4.1.2007.1.4.72.1.53.2
Parameter 'RIF-length' in event SRT.53
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt53-source-mac 1.3.6.1.4.1.2007.1.4.72.1.53.3
Parameter 'source-mac' in event SRT.53
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt53-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.53.4
Parameter 'dest-mac' in event SRT.53
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt53-port 1.3.6.1.4.1.2007.1.4.72.1.53.5
Parameter 'port' in event SRT.53
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt53-interface 1.3.6.1.4.1.2007.1.4.72.1.53.6
Parameter 'interface' in event SRT.53
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt53-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.53.7
Parameter 'circuit-name' in event SRT.53
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects54 1.3.6.1.4.1.2007.1.4.72.1.54
Event SRT.54 There is not enough free memory to allocate the hash table for the filtering database. The bridge will be disabled.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt54-requested-size 1.3.6.1.4.1.2007.1.4.72.1.54.1
Parameter 'requested-size' in event SRT.54
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srtEventObjects55 1.3.6.1.4.1.2007.1.4.72.1.55
Event SRT.55 There is not enough free memory to allocate the hash table for the conversion database. The bridge will be disabled.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt55-requested-size 1.3.6.1.4.1.2007.1.4.72.1.55.1
Parameter 'requested-size' in event SRT.55
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srtEventObjects56 1.3.6.1.4.1.2007.1.4.72.1.56
Event SRT.56 The input queue for source-routed frames to be forwarded is too long, and this frame has been dropped to attempt to alleviate the congestion.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt56-source-mac 1.3.6.1.4.1.2007.1.4.72.1.56.1
Parameter 'source-mac' in event SRT.56
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt56-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.56.2
Parameter 'dest-mac' in event SRT.56
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt56-interface 1.3.6.1.4.1.2007.1.4.72.1.56.3
Parameter 'interface' in event SRT.56
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt56-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.56.4
Parameter 'circuit-name' in event SRT.56
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects57 1.3.6.1.4.1.2007.1.4.72.1.57
Event SRT.57 A frame is being bridged between these two interfaces. The destination address was known, so it was sent only to the correct destination network.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt57-source-mac 1.3.6.1.4.1.2007.1.4.72.1.57.1
Parameter 'source-mac' in event SRT.57
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt57-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.57.2
Parameter 'dest-mac' in event SRT.57
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt57-port 1.3.6.1.4.1.2007.1.4.72.1.57.3
Parameter 'port' in event SRT.57
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt57-interface 1.3.6.1.4.1.2007.1.4.72.1.57.4
Parameter 'interface' in event SRT.57
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt57-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.57.5
Parameter 'circuit-name' in event SRT.57
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt57-out-port 1.3.6.1.4.1.2007.1.4.72.1.57.6
Parameter 'out-port' in event SRT.57
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt57-out-interface 1.3.6.1.4.1.2007.1.4.72.1.57.7
Parameter 'out-interface' in event SRT.57
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt57-out-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.57.8
Parameter 'out-circuit-name' in event SRT.57
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects58 1.3.6.1.4.1.2007.1.4.72.1.58
Event SRT.58 The specified transparent bridge frame is too large to send as a source-routed frame on this outgoing port and interface. The reformatted-length is the size of the frame including MAC headers and RIF after any mapping of data link headers.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt58-source-mac 1.3.6.1.4.1.2007.1.4.72.1.58.1
Parameter 'source-mac' in event SRT.58
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt58-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.58.2
Parameter 'dest-mac' in event SRT.58
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt58-reformatted-length 1.3.6.1.4.1.2007.1.4.72.1.58.3
Parameter 'reformatted-length' in event SRT.58
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt58-output-maximum 1.3.6.1.4.1.2007.1.4.72.1.58.4
Parameter 'output-maximum' in event SRT.58
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt58-port 1.3.6.1.4.1.2007.1.4.72.1.58.5
Parameter 'port' in event SRT.58
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt58-interface 1.3.6.1.4.1.2007.1.4.72.1.58.6
Parameter 'interface' in event SRT.58
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt58-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.58.7
Parameter 'circuit-name' in event SRT.58
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects59 1.3.6.1.4.1.2007.1.4.72.1.59
Event SRT.59 A frame is being conversion bridged between these two interfaces. The destination address and RIF were known, so it was sent only to the correct destination network.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt59-source-mac 1.3.6.1.4.1.2007.1.4.72.1.59.1
Parameter 'source-mac' in event SRT.59
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt59-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.59.2
Parameter 'dest-mac' in event SRT.59
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt59-RIF 1.3.6.1.4.1.2007.1.4.72.1.59.3
Parameter 'RIF' in event SRT.59
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt59-port 1.3.6.1.4.1.2007.1.4.72.1.59.4
Parameter 'port' in event SRT.59
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt59-interface 1.3.6.1.4.1.2007.1.4.72.1.59.5
Parameter 'interface' in event SRT.59
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt59-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.59.6
Parameter 'circuit-name' in event SRT.59
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt59-out-port 1.3.6.1.4.1.2007.1.4.72.1.59.7
Parameter 'out-port' in event SRT.59
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt59-out-interface 1.3.6.1.4.1.2007.1.4.72.1.59.8
Parameter 'out-interface' in event SRT.59
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt59-out-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.59.9
Parameter 'out-circuit-name' in event SRT.59
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects60 1.3.6.1.4.1.2007.1.4.72.1.60
Event SRT.60 A frame is being conversion bridged to all active source-routing ports. This happens when the frame destination is a multicast or when the frame destination is not in the source-routing learning database. There will be one message for each port the frame is sent on.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt60-source-mac 1.3.6.1.4.1.2007.1.4.72.1.60.1
Parameter 'source-mac' in event SRT.60
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt60-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.60.2
Parameter 'dest-mac' in event SRT.60
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt60-RIF 1.3.6.1.4.1.2007.1.4.72.1.60.3
Parameter 'RIF' in event SRT.60
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt60-port 1.3.6.1.4.1.2007.1.4.72.1.60.4
Parameter 'port' in event SRT.60
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt60-interface 1.3.6.1.4.1.2007.1.4.72.1.60.5
Parameter 'interface' in event SRT.60
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt60-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.60.6
Parameter 'circuit-name' in event SRT.60
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt60-out-port 1.3.6.1.4.1.2007.1.4.72.1.60.7
Parameter 'out-port' in event SRT.60
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt60-out-interface 1.3.6.1.4.1.2007.1.4.72.1.60.8
Parameter 'out-interface' in event SRT.60
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt60-out-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.60.9
Parameter 'out-circuit-name' in event SRT.60
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects61 1.3.6.1.4.1.2007.1.4.72.1.61
Event SRT.61 A Specifically Routed frame has been received whose RIF would send it on the specified port, but that port is not configured for bridging.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt61-source-mac 1.3.6.1.4.1.2007.1.4.72.1.61.1
Parameter 'source-mac' in event SRT.61
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt61-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.61.2
Parameter 'dest-mac' in event SRT.61
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt61-RIF 1.3.6.1.4.1.2007.1.4.72.1.61.3
Parameter 'RIF' in event SRT.61
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt61-port 1.3.6.1.4.1.2007.1.4.72.1.61.4
Parameter 'port' in event SRT.61
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt61-interface 1.3.6.1.4.1.2007.1.4.72.1.61.5
Parameter 'interface' in event SRT.61
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt61-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.61.6
Parameter 'circuit-name' in event SRT.61
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects62 1.3.6.1.4.1.2007.1.4.72.1.62
Event SRT.62 The specified source-routed frame is larger than that is allowed by LF-BIT configuration for the transparent bridge domain. After mapping to the MAC headers of the outgoing port, the packet may get dropped if it exceeds the MSDU limit of the port.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt62-source-mac 1.3.6.1.4.1.2007.1.4.72.1.62.1
Parameter 'source-mac' in event SRT.62
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt62-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.62.2
Parameter 'dest-mac' in event SRT.62
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt62-reformatted-length 1.3.6.1.4.1.2007.1.4.72.1.62.3
Parameter 'reformatted-length' in event SRT.62
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt62-output-maximum 1.3.6.1.4.1.2007.1.4.72.1.62.4
Parameter 'output-maximum' in event SRT.62
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt62-port 1.3.6.1.4.1.2007.1.4.72.1.62.5
Parameter 'port' in event SRT.62
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt62-interface 1.3.6.1.4.1.2007.1.4.72.1.62.6
Parameter 'interface' in event SRT.62
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt62-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.62.7
Parameter 'circuit-name' in event SRT.62
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects63 1.3.6.1.4.1.2007.1.4.72.1.63
Event SRT.63 No buffer available to copy a frame in order to send Routes Explorer (ARE) or Spanning Tree Explorer (STE) routing-type frame out as a transparent bridged frame in the transparent bridging domain. No copy of this frame will be sent into the transparent bridge domain.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt63-routing-type 1.3.6.1.4.1.2007.1.4.72.1.63.1
Parameter 'routing-type' in event SRT.63
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt63-source-mac 1.3.6.1.4.1.2007.1.4.72.1.63.2
Parameter 'source-mac' in event SRT.63
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt63-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.63.3
Parameter 'dest-mac' in event SRT.63
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt63-port 1.3.6.1.4.1.2007.1.4.72.1.63.4
Parameter 'port' in event SRT.63
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt63-interface 1.3.6.1.4.1.2007.1.4.72.1.63.5
Parameter 'interface' in event SRT.63
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt63-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.63.6
Parameter 'circuit-name' in event SRT.63
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects64 1.3.6.1.4.1.2007.1.4.72.1.64
Event SRT.64 There is not enough free memory to allocate even a minimal size conversion database. The bridge will be disabled.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt64-requested-size 1.3.6.1.4.1.2007.1.4.72.1.64.1
Parameter 'requested-size' in event SRT.64
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srtEventObjects65 1.3.6.1.4.1.2007.1.4.72.1.65
Event SRT.65 An attempt to add a particular static entry to the internal database of a bridging interface having internal filtering failed.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt65-MAC-address 1.3.6.1.4.1.2007.1.4.72.1.65.1
Parameter 'MAC-address' in event SRT.65
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt65-interface 1.3.6.1.4.1.2007.1.4.72.1.65.2
Parameter 'interface' in event SRT.65
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects66 1.3.6.1.4.1.2007.1.4.72.1.66
Event SRT.66 The bridge has been configured to enable transparent bridging on an IEEE 802.5 Token-Ring interface that does not have the hardware to support transparent bridging. Transparent bridging will not be enabled on this interface.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt66-interface 1.3.6.1.4.1.2007.1.4.72.1.66.1
Parameter 'interface' in event SRT.66
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt66-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.66.2
Parameter 'circuit-name' in event SRT.66
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects67 1.3.6.1.4.1.2007.1.4.72.1.67
Event SRT.67 A Specifically Routed frame has been sent on a port, but that port is not configured for bridging. This should never happen, since prior checks should prevent calling this code if the port is not configured for bridging.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt67-source-mac 1.3.6.1.4.1.2007.1.4.72.1.67.1
Parameter 'source-mac' in event SRT.67
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt67-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.67.2
Parameter 'dest-mac' in event SRT.67
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt67-RIF 1.3.6.1.4.1.2007.1.4.72.1.67.3
Parameter 'RIF' in event SRT.67
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt67-port 1.3.6.1.4.1.2007.1.4.72.1.67.4
Parameter 'port' in event SRT.67
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt67-interface 1.3.6.1.4.1.2007.1.4.72.1.67.5
Parameter 'interface' in event SRT.67
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt67-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.67.6
Parameter 'circuit-name' in event SRT.67
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects68 1.3.6.1.4.1.2007.1.4.72.1.68
Event SRT.68 There is no space in the Ethernet type registration table for the specified ethernet-type. This happens when there are too many hash collisions, and there are not enough overflow buckets.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt68-ethernet-type 1.3.6.1.4.1.2007.1.4.72.1.68.1
Parameter 'ethernet-type' in event SRT.68
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srtEventObjects69 1.3.6.1.4.1.2007.1.4.72.1.69
Event SRT.69 There is no space in the SNAP PID registration table for the specified protocol. This happens when there are too many hash collisions, and there are not enough overflow buckets.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt69-protocol 1.3.6.1.4.1.2007.1.4.72.1.69.1
Parameter 'protocol' in event SRT.69
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srtEventObjects70 1.3.6.1.4.1.2007.1.4.72.1.70
Event SRT.70 A MAC frame has been received by the hardware, but is being dropped because the destination MAC address is being administratively filtered by the bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt70-source-mac 1.3.6.1.4.1.2007.1.4.72.1.70.1
Parameter 'source-mac' in event SRT.70
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt70-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.70.2
Parameter 'dest-mac' in event SRT.70
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt70-port 1.3.6.1.4.1.2007.1.4.72.1.70.3
Parameter 'port' in event SRT.70
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt70-interface 1.3.6.1.4.1.2007.1.4.72.1.70.4
Parameter 'interface' in event SRT.70
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt70-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.70.5
Parameter 'circuit-name' in event SRT.70
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects71 1.3.6.1.4.1.2007.1.4.72.1.71
Event SRT.71 Source Routing is configured on the port which is attached to an underlying network which inherently does not support source routing type of functionalities. Such networks are Ethernet and FDDI. Bridge disables source routing on the port.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt71-port 1.3.6.1.4.1.2007.1.4.72.1.71.1
Parameter 'port' in event SRT.71
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt71-interface 1.3.6.1.4.1.2007.1.4.72.1.71.2
Parameter 'interface' in event SRT.71
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt71-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.71.3
Parameter 'circuit-name' in event SRT.71
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects74 1.3.6.1.4.1.2007.1.4.72.1.74
Event SRT.74 Source-routing bridging has been enabled, but that feature was not purchased as part of this software load. The source-routing bridging feature will not be enabled.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt74-interface 1.3.6.1.4.1.2007.1.4.72.1.74.1
Parameter 'interface' in event SRT.74
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt74-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.74.2
Parameter 'circuit-name' in event SRT.74
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects75 1.3.6.1.4.1.2007.1.4.72.1.75
Event SRT.75 Spanning tree (transparent) bridging has been enabled, but that feature was not purchased as part of this software load. The spanning tree (transparent) bridging feature will not be enabled.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt75-interface 1.3.6.1.4.1.2007.1.4.72.1.75.1
Parameter 'interface' in event SRT.75
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt75-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.75.2
Parameter 'circuit-name' in event SRT.75
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects77 1.3.6.1.4.1.2007.1.4.72.1.77
Event SRT.77 The user deleted a filter list, which was part of an already configured filter. The filter will not be enabled.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt77-input-output 1.3.6.1.4.1.2007.1.4.72.1.77.1
Parameter 'input-output' in event SRT.77
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt77-port-number 1.3.6.1.4.1.2007.1.4.72.1.77.2
Parameter 'port-number' in event SRT.77
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srtEventObjects78 1.3.6.1.4.1.2007.1.4.72.1.78
Event SRT.78 The user configured a NETBIOS filter for a particular port, but that port number is not configured.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt78-input-output 1.3.6.1.4.1.2007.1.4.72.1.78.1
Parameter 'input-output' in event SRT.78
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt78-port-number 1.3.6.1.4.1.2007.1.4.72.1.78.2
Parameter 'port-number' in event SRT.78
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srtEventObjects79 1.3.6.1.4.1.2007.1.4.72.1.79
Event SRT.79 A NETBIOS packet has matched the criteria specified in a NETBIOS Filter configuration record. The packet is dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt79-source-mac 1.3.6.1.4.1.2007.1.4.72.1.79.1
Parameter 'source-mac' in event SRT.79
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt79-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.79.2
Parameter 'dest-mac' in event SRT.79
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt79-port 1.3.6.1.4.1.2007.1.4.72.1.79.3
Parameter 'port' in event SRT.79
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt79-interface 1.3.6.1.4.1.2007.1.4.72.1.79.4
Parameter 'interface' in event SRT.79
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt79-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.79.5
Parameter 'circuit-name' in event SRT.79
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects81 1.3.6.1.4.1.2007.1.4.72.1.81
Event SRT.81 A NETBIOS STE converted to SRF by NETBIOS Name Caching.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt81-RIF 1.3.6.1.4.1.2007.1.4.72.1.81.1
Parameter 'RIF' in event SRT.81
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt81-source-mac 1.3.6.1.4.1.2007.1.4.72.1.81.2
Parameter 'source-mac' in event SRT.81
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt81-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.81.3
Parameter 'dest-mac' in event SRT.81
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt81-port 1.3.6.1.4.1.2007.1.4.72.1.81.4
Parameter 'port' in event SRT.81
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srtEventObjects83 1.3.6.1.4.1.2007.1.4.72.1.83
Event SRT.83 A NETBIOS find-name STE has been filtered.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt83-RIF 1.3.6.1.4.1.2007.1.4.72.1.83.1
Parameter 'RIF' in event SRT.83
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt83-source-mac 1.3.6.1.4.1.2007.1.4.72.1.83.2
Parameter 'source-mac' in event SRT.83
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt83-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.83.3
Parameter 'dest-mac' in event SRT.83
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt83-port 1.3.6.1.4.1.2007.1.4.72.1.83.4
Parameter 'port' in event SRT.83
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srtEventObjects84 1.3.6.1.4.1.2007.1.4.72.1.84
Event SRT.84 A spanning tree BPDU frame was received on a port that has been disabled for spanning tree participation by the 'disable tree port#' command.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt84-port 1.3.6.1.4.1.2007.1.4.72.1.84.1
Parameter 'port' in event SRT.84
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt84-interface 1.3.6.1.4.1.2007.1.4.72.1.84.2
Parameter 'interface' in event SRT.84
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects85 1.3.6.1.4.1.2007.1.4.72.1.85
Event SRT.85 The port has been configured to use a Frame Relay interface. However, subsequent to bridge configuration, device configuration changed such that the device is no longer configured to be a Frame Relay device. This could have happened if the user changed the data link support on the device, or re-ordered the device records.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt85-port 1.3.6.1.4.1.2007.1.4.72.1.85.1
Parameter 'port' in event SRT.85
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt85-interface-number 1.3.6.1.4.1.2007.1.4.72.1.85.2
Parameter 'interface-number' in event SRT.85
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srtEventObjects86 1.3.6.1.4.1.2007.1.4.72.1.86
Event SRT.86 During bridge initialization, ports are associated with Frame Relay registers with the Frame Relay interface. During registration, both let each other know about their existence and exchange some useful information to keep about each other.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt86-port 1.3.6.1.4.1.2007.1.4.72.1.86.1
Parameter 'port' in event SRT.86
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt86-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.86.2
Parameter 'circuit-name' in event SRT.86
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt86-interface 1.3.6.1.4.1.2007.1.4.72.1.86.3
Parameter 'interface' in event SRT.86
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt86-reason 1.3.6.1.4.1.2007.1.4.72.1.86.4
Parameter 'reason' in event SRT.86
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects87 1.3.6.1.4.1.2007.1.4.72.1.87
Event SRT.87 An All Routes Explorer (ARE) source-routed frame has more Route Descriptors than this bridge is configured to allow for ARE frames. The frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt87-source-mac 1.3.6.1.4.1.2007.1.4.72.1.87.1
Parameter 'source-mac' in event SRT.87
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt87-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.87.2
Parameter 'dest-mac' in event SRT.87
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt87-port 1.3.6.1.4.1.2007.1.4.72.1.87.3
Parameter 'port' in event SRT.87
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt87-interface 1.3.6.1.4.1.2007.1.4.72.1.87.4
Parameter 'interface' in event SRT.87
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt87-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.87.5
Parameter 'circuit-name' in event SRT.87
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects89 1.3.6.1.4.1.2007.1.4.72.1.89
Event SRT.89 A frame is being bridged between these two interfaces. The destination address was broadcast or unregistered.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt89-source-mac 1.3.6.1.4.1.2007.1.4.72.1.89.1
Parameter 'source-mac' in event SRT.89
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt89-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.89.2
Parameter 'dest-mac' in event SRT.89
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt89-port 1.3.6.1.4.1.2007.1.4.72.1.89.3
Parameter 'port' in event SRT.89
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt89-interface 1.3.6.1.4.1.2007.1.4.72.1.89.4
Parameter 'interface' in event SRT.89
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt89-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.89.5
Parameter 'circuit-name' in event SRT.89
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt89-out-port 1.3.6.1.4.1.2007.1.4.72.1.89.6
Parameter 'out-port' in event SRT.89
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srt89-out-interface 1.3.6.1.4.1.2007.1.4.72.1.89.7
Parameter 'out-interface' in event SRT.89
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt89-out-circuit-name 1.3.6.1.4.1.2007.1.4.72.1.89.8
Parameter 'out-circuit-name' in event SRT.89
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srtEventObjects90 1.3.6.1.4.1.2007.1.4.72.1.90
Event SRT.90 A VLAN tagged frame on a ethernet subinterface was received but bridging is disabled for vlans. The frame will not be bridged.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

srt90-source-mac 1.3.6.1.4.1.2007.1.4.72.1.90.1
Parameter 'source-mac' in event SRT.90
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt90-dest-mac 1.3.6.1.4.1.2007.1.4.72.1.90.2
Parameter 'dest-mac' in event SRT.90
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

srt90-vid 1.3.6.1.4.1.2007.1.4.72.1.90.3
Parameter 'vid' in event SRT.90
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

srtNotification1 1.3.6.1.4.1.2007.1.4.72.2.0.1
Notification of Event SRT.1 Message: 'No buffer available to duplicate frame from $1 to $2 on port $3, interface $4$5' Parameters list: $1: srt1-source-mac $2: srt1-dest-mac $3: srt1-port $4: srt1-interface $5: srt1-circuit-name No buffer available to copy a frame in order to send a bridged frame on multiple interfaces. Bridged packets are sent on multiple interfaces either for multicast destination addresses, or in the case of certain static entries. No copy of this frame will be sent on the specified port and interface.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification2 1.3.6.1.4.1.2007.1.4.72.2.0.2
Notification of Event SRT.2 Message: 'Error code $1 trying to set promiscuous mode on interface $2$3' Parameters list: $1: srt2-error-code $2: srt2-interface $3: srt2-circuit-name The Spanning Tree Protocol requested setting this network into Learning state, but the command to the device failed. The error-code is a device-specific error code that may indicate what the error is.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification3 1.3.6.1.4.1.2007.1.4.72.2.0.3
Notification of Event SRT.3 Message: 'Error code $1 trying to add static entries on interface $2$3' Parameters list: $1: srt3-error-code $2: srt3-interface $3: srt3-circuit-name An attempt to add a set of static entries to the internal database of a bridging interface having internal filtering failed. The error-code is a device-specific error code that may indicate what the error is.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification4 1.3.6.1.4.1.2007.1.4.72.2.0.4
Notification of Event SRT.4 Message: 'No buffer available for $1 command to interface $2' Parameters list: $1: srt4-command-name $2: srt4-interface No buffer was available to send a command to the device. The possible command names are 'D-CNFGSRB' (configure source-routing bridging), 'SRT-ON' (promiscuous on), 'SRT-INFORM' (learn capabilities of device), 'SRT-SET-AGE' (set age for filtering database in device), 'SRT-DECR-AGE' (do ageing pass on filtering database in device), 'SRT-ADD-ENTRY' (add static entry), 'SRT-DEL-ENTRY' (delete entry, from console), 'SRT-SEARCH-ENTRY' (search for particular entry, from console) and 'SRT-LIST-ENTRY' (list contents of learning database in card). For commands 'D-CNFGSRB' and 'SRT-ON' the result will be that the interface may remain in the wrong state. A failure on 'SRT-INFORM' could cause serious problems. For other commands the results will be less serious.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification5 1.3.6.1.4.1.2007.1.4.72.2.0.5
Notification of Event SRT.5 Message: 'Sending frame from $1 to $2 failed, reason $3, on port $4 interface $5$6' Parameters list: $1: srt5-source-mac $2: srt5-dest-mac $3: srt5-reason-code $4: srt5-port $5: srt5-interface-name $6: srt5-circuit-name The sending of a packet being forwarded failed. The reason is the internal error code for the failure.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification6 1.3.6.1.4.1.2007.1.4.72.2.0.6
Notification of Event SRT.6 Message: 'Input queue overflow on frame from $1 to $2, packet dropped interface $3$4' Parameters list: $1: srt6-source-mac $2: srt6-dest-mac $3: srt6-interface $4: srt6-circuit-name The input queue for frames to be forwarded is too long, and this frame has been dropped to attempt to alleviate the congestion.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification7 1.3.6.1.4.1.2007.1.4.72.2.0.7
Notification of Event SRT.7 Message: 'Bridge Protocol Data Unit input queue overflow on frame from $1, dropped from interface $2$3' Parameters list: $1: srt7-source-mac $2: srt7-interface $3: srt7-circuit-name The input queue for Spanning Tree Protocol Bridge Protocl Data Units is too long, and this frame has been dropped to attempt to alleviate the congestion.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification8 1.3.6.1.4.1.2007.1.4.72.2.0.8
Notification of Event SRT.8 Message: 'Frame from $1 to $2 is too big (reformatted length $3 bytes > output maximum size $4 bytes) for port $5 interface $6$7, dropped' Parameters list: $1: srt8-source-mac $2: srt8-dest-mac $3: srt8-reformatted-length $4: srt8-output-maximum $5: srt8-port $6: srt8-interface $7: srt8-circuit-name The specified frame is too large to send on this outgoing port and interface. The reformatted-length is the size of the frame including MAC headers after any mapping of data link headers.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification9 1.3.6.1.4.1.2007.1.4.72.2.0.9
Notification of Event SRT.9 Message: 'Frame from $1 to $2 dropped, input interface $3 is down' Parameters list: $1: srt9-source-mac $2: srt9-dest-mac $3: srt9-interface A frame has been received for bridging on an interface that is down. It will be ignored.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification10 1.3.6.1.4.1.2007.1.4.72.2.0.10
Notification of Event SRT.10 Message: 'Frame from $1 to $2 dropped, source address filtered, port $3 interface $4$5' Parameters list: $1: srt10-source-mac $2: srt10-dest-mac $3: srt10-port $4: srt10-interface $5: srt10-circuit-name A MAC frame has been received by the hardware, but is being dropped because the source MAC address is being administratively filtered by the bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification11 1.3.6.1.4.1.2007.1.4.72.2.0.11
Notification of Event SRT.11 Message: 'Frame from $1 to $2 dropped, input port $3 interface $4$5 not in forwarding state' Parameters list: $1: srt11-source-mac $2: srt11-dest-mac $3: srt11-port $4: srt11-interface $5: srt11-circuit-name A MAC frame was received on a port that is still only in 'learning' state. Frames are only bridged when the input port is in 'forwarding' state. While the port is still in 'learning' state, they are only processed to learn the source addresses for the filtering database. The frame will not be bridged.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification12 1.3.6.1.4.1.2007.1.4.72.2.0.12
Notification of Event SRT.12 Message: 'Frame from $1 to $2 dropped, output port $3 interface $4$5 not in forwarding state' Parameters list: $1: srt12-source-mac $2: srt12-dest-mac $3: srt12-port $4: srt12-interface $5: srt12-circuit-name A MAC frame was being bridged, but the destination port was not in 'forwarding' state. It will not be sent on that port.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification13 1.3.6.1.4.1.2007.1.4.72.2.0.13
Notification of Event SRT.13 Message: 'Frame from $1 to $2 dropped, destination on same LAN, port $3 interface $4$5' Parameters list: $1: srt13-source-mac $2: srt13-dest-mac $3: srt13-port $4: srt13-interface $5: srt13-circuit-name A MAC frame has been received whose destination address is known to be on the same side of the bridge as the packet came from. It is dropped by the filtering logic since it does not need to be bridged.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification14 1.3.6.1.4.1.2007.1.4.72.2.0.14
Notification of Event SRT.14 Message: 'Frame from $1 to $2 dropped, destination port $3 not enabled, interface $4$5' Parameters list: $1: srt14-source-mac $2: srt14-dest-mac $3: srt14-port $4: srt14-interface $5: srt14-circuit-name A frame being bridged was destined for a port which is not running transparent bridging, or not in 'forwarding' state for transparent bridging.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification15 1.3.6.1.4.1.2007.1.4.72.2.0.15
Notification of Event SRT.15 Message: 'Frame from $1 to $2 bridged from port number $3 interface $4$5 to port number $6 interface $7$8' Parameters list: $1: srt15-source-mac $2: srt15-dest-mac $3: srt15-port $4: srt15-interface $5: srt15-circuit-name $6: srt15-out-port $7: srt15-out-interface $8: srt15-out-circuit-name A frame is being bridged between these two interfaces. The destination address was known, so it was sent only to the correct destination network.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification16 1.3.6.1.4.1.2007.1.4.72.2.0.16
Notification of Event SRT.16 Message: 'Frame from $1 to $2 bridged to all ports from port number $3 interface $4$5 to port number $6 interface $7$8' Parameters list: $1: srt16-source-mac $2: srt16-dest-mac $3: srt16-port $4: srt16-interface $5: srt16-circuit-name $6: srt16-out-port $7: srt16-out-interface $8: srt16-out-circuit-name A frame is being transparently bridged to all active transparent bridging ports. This happens when the frame destination is a multicast, when the frame destination is not in the learning database, or when required by static entries in the learning database. There will be one message for each port the frame is sent on.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification17 1.3.6.1.4.1.2007.1.4.72.2.0.17
Notification of Event SRT.17 Message: 'Enabling SRT on port $1 interface $2$3' Parameters list: $1: srt17-port $2: srt17-interface $3: srt17-circuit-name The SRT forwarder is starting the process of enabling bridging on the specified interface. This starts when the interface comes up from a self-test.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification18 1.3.6.1.4.1.2007.1.4.72.2.0.18
Notification of Event SRT.18 Message: 'SRT startup complete on port $1 interface $2$3' Parameters list: $1: srt18-port $2: srt18-interface $3: srt18-circuit-name The SRT forwarder has completed the process of enabling bridging on the specified interface. It will now enter 'blocking' state.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification19 1.3.6.1.4.1.2007.1.4.72.2.0.19
Notification of Event SRT.19 Message: 'Unsupported interface $1' Parameters list: $1: srt19-interface-name The SRT forwarder had been enabled on a type of interface it does not support.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification20 1.3.6.1.4.1.2007.1.4.72.2.0.20
Notification of Event SRT.20 Message: 'Cannot autoconfigure the bridge address, the lowest numbered port $1 interface $2$3 has no MAC address' Parameters list: $1: srt20-port $2: srt20-interface $3: srt20-circuit-name The user has configured the bridge to autoconfigure the bridge address based on the MAC address of the lowest number port. However, the lowest numbered port is of a type that does not have a MAC address, such as a serial line.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification21 1.3.6.1.4.1.2007.1.4.72.2.0.21
Notification of Event SRT.21 Message: 'Bridge frame from $1 to $2, no forwarder, interface $3' Parameters list: $1: srt21-source-mac $2: srt21-dest-mac $3: srt21-interface Bridge frame received, but there is no bridging available in this load. The frame will be ignored.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification22 1.3.6.1.4.1.2007.1.4.72.2.0.22
Notification of Event SRT.22 Message: 'Bridge configured with no ports on it, disabling the bridge' The bridge has been enabled, but there are no ports configured on that bridge. The bridge will be left disabled. It takes at least two ports to be a bridge.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification23 1.3.6.1.4.1.2007.1.4.72.2.0.23
Notification of Event SRT.23 Message: 'Port $1 configured on nonexistent interface number $2' Parameters list: $1: srt23-port $2: srt23-interface-number The port has been configured to use an interface that has not been configured with the Config> ADD DEVICE command. This port of the bridge will be disabled.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification24 1.3.6.1.4.1.2007.1.4.72.2.0.24
Notification of Event SRT.24 Message: '$1 existent ports is less than 2, disabling bridge' Parameters list: $1: srt24-existent-port-count Less than two (valid) ports have been configured on the bridge. There must be at least two ports.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification25 1.3.6.1.4.1.2007.1.4.72.2.0.25
Notification of Event SRT.25 Message: 'No memory for filtering database (desired size $1 bytes, absolute minimum size $2 bytes), disabling bridge' Parameters list: $1: srt25-requested-size $2: srt25-minimum-size There is not enough free memory to allocate even a minimal size filtering database. The bridge will be disabled. The bridge starts by trying to allocate requested-size bytes, and then tries with progressively smaller sizes down to minimum-size. The minimum size is enough only for the registered and static entries.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification26 1.3.6.1.4.1.2007.1.4.72.2.0.26
Notification of Event SRT.26 Message: 'Frame from $1 to $2, source same as destination, dropping, from port $3 interface $4$5' Parameters list: $1: srt26-source-mac $2: srt26-dest-mac $3: srt26-port $4: srt26-interface $5: srt26-circuit-name Frames to and from the same address are not bridged by this bridge.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification27 1.3.6.1.4.1.2007.1.4.72.2.0.27
Notification of Event SRT.27 Message: 'Changing port state from $1 to $2 for port $3, interface $4$5' Parameters list: $1: srt27-old-state $2: srt27-new-state $3: srt27-port $4: srt27-interface $5: srt27-circuit-name The Spanning Tree Protocol has requested this state change for this port in the SRT bridge. The old-state and new-state are one of: FORWARDING (Spanning Tree Protocol Forwarding state), LEARNING (Spanning Tree Protocol Learning state), LISTENING (Spanning Tree Protocol Listening state), BLOCKED (Spanning Tree Protocol Blocking state), CONFIGURING (configuration of port device pending), POSTCONFIGURING (configuration of port device done), PRECONFIGURING (port enabled, configuration of port device to start) and DISABLED (port disabled).
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification28 1.3.6.1.4.1.2007.1.4.72.2.0.28
Notification of Event SRT.28 Message: 'No room for permanent address $1 in filtering database, disabling bridge' Parameters list: $1: srt28-mac-address There is no room for the permanent entry in the filtering database. The bridge will be disabled.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification29 1.3.6.1.4.1.2007.1.4.72.2.0.29
Notification of Event SRT.29 Message: 'No memory for permanent address $1, disabling bridge' Parameters list: $1: srt29-mac-address There is no room for the permanent entry in an auxiliary database. The bridge will be disabled.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification30 1.3.6.1.4.1.2007.1.4.72.2.0.30
Notification of Event SRT.30 Message: '$1 command failed to interface $2' Parameters list: $1: srt30-command $2: srt30-interface A command to a network device failed. The possible command names are 'SRT-ON' (promiscuous on), 'SRT-OFF' (promiscuous off), 'SRT-INFORM' (learn capabilities of device), 'SRT-ADD-ENTRY' (add static entry in device), 'SRT-SET-AGE' (set age for filtering database in device) and 'SRT-DECR-AGE' (do ageing pass on filtering database in device). For commands 'SRT-ON' and 'SRT-OFF' the result will be that the interface may remain in the worong state. A failure on 'SRT-INFORM' could cause serious problems. For other commands the results will be less serious.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification31 1.3.6.1.4.1.2007.1.4.72.2.0.31
Notification of Event SRT.31 Message: 'No buffer available to duplicate $1 frame from $2 to $3 on port $4, interface $5$6' Parameters list: $1: srt31-routing-type $2: srt31-source-mac $3: srt31-dest-mac $4: srt31-port $5: srt31-interface $6: srt31-circuit-name No buffer available to copy a frame in order to send an All Routes Explorer (ARE) or Spanning Tree Explorer (STE) routing-type frame on multiple interfaces. ARE frames are sent on all interfaces which are part of the SRT spanning tree, STE frames are sent on all interfaces running source-routing. No copy of this frame will be sent on the specified port and interface.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification32 1.3.6.1.4.1.2007.1.4.72.2.0.32
Notification of Event SRT.32 Message: 'Sending source routed frame from $1 to $2 failed, reason $3, on port $4 interface $5$6' Parameters list: $1: srt32-source-mac $2: srt32-dest-mac $3: srt32-reason-code $4: srt32-port $5: srt32-interface-name $6: srt32-circuit-name The sending of a source routed frame being forwarded failed. The reason-code is the internal error code for the failure.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification33 1.3.6.1.4.1.2007.1.4.72.2.0.33
Notification of Event SRT.33 Message: '$1 with duplicate Route Descriptor from $2 to $3 from port $4, interface $5$6' Parameters list: $1: srt33-routing-type $2: srt33-source-mac $3: srt33-dest-mac $4: srt33-port $5: srt33-interface $6: srt33-circuit-name A source-routed frame having a All Routes Descriptor (ARE) or Spanning Tree Explorer (STE) routing-type in the RIF has a duplicate Routing Descriptor in the RIF. The frame will be dropped. This is a normal occurrence for ARE frames when there are any duplicate paths in the source routing domain. For STE frames, this indicates that there is an interface that is part of the source-routing spanning tree that should not be.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification34 1.3.6.1.4.1.2007.1.4.72.2.0.34
Notification of Event SRT.34 Message: 'SRF with duplicate LOUT (RIF $1) from $2 to $3 from port $4, interface $5$6' Parameters list: $1: srt34-RIF $2: srt34-source-mac $3: srt34-dest-mac $4: srt34-port $5: srt34-interface $6: srt34-circuit-name A source-routed frame of Specifically-routed frame (SRF) type has a duplicate LOUT (outgoing LAN ID). This is illegal, and the frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification35 1.3.6.1.4.1.2007.1.4.72.2.0.35
Notification of Event SRT.35 Message: 'All Routes Explorer exceeds maximum Route Descriptors (RIF $1) from $2 to $3 from port $4, interface $5$6, dropped' Parameters list: $1: srt35-RIF $2: srt35-source-mac $3: srt35-dest-mac $4: srt35-port $5: srt35-interface $6: srt35-circuit-name An All Routes Explorer (ARE) source-routed frame has more Route Descriptors than this bridge is configured to allow for ARE frames. The frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification36 1.3.6.1.4.1.2007.1.4.72.2.0.36
Notification of Event SRT.36 Message: 'Spanning Tree Explorer exceeds maximum Route Descriptors (RIF $1) from $2 to $3 from port $4, interface $5$6' Parameters list: $1: srt36-RIF $2: srt36-source-mac $3: srt36-dest-mac $4: srt36-port $5: srt36-interface $6: srt36-circuit-name A Spanning Tree Explorer (STE) source-routed frame has more Route Descriptors than this bridge is configured to allow for STE frames. The frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification37 1.3.6.1.4.1.2007.1.4.72.2.0.37
Notification of Event SRT.37 Message: 'SRF with unknown LOUT (RIF $1) from $2 to $3 from port $4, interface $5' Parameters list: $1: srt37-RIF $2: srt37-source-mac $3: srt37-dest-mac $4: srt37-port $5: srt37-interface A source-routed frame of Specifically-routed frame (SRF) type has an outgoing LOUT (LAN ID Out) that does not match that of any active source-routing interface in the router. It will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification38 1.3.6.1.4.1.2007.1.4.72.2.0.38
Notification of Event SRT.38 Message: 'All Routes Explorer received (RIF $1) from $2 to $3 from port $4, interface $5$6' Parameters list: $1: srt38-RIF $2: srt38-source-mac $3: srt38-dest-mac $4: srt38-port $5: srt38-interface $6: srt38-circuit-name An All Routes Explorer frame has been received on the specified port.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification39 1.3.6.1.4.1.2007.1.4.72.2.0.39
Notification of Event SRT.39 Message: 'All Routes Explorer sent (RIF $1) from $2 to $3 to port $4, interface $5$6' Parameters list: $1: srt39-RIF $2: srt39-source-mac $3: srt39-dest-mac $4: srt39-port $5: srt39-interface $6: srt39-circuit-name An All Routes Explorer frame has been sent on the specified port.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification40 1.3.6.1.4.1.2007.1.4.72.2.0.40
Notification of Event SRT.40 Message: 'Spanning Tree Explorer received (RIF $1) from $2 to $3 from port $4, interface $5$6' Parameters list: $1: srt40-RIF $2: srt40-source-mac $3: srt40-dest-mac $4: srt40-port $5: srt40-interface $6: srt40-circuit-name A Spanning Tree Explorer frame has been received on the specified port.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification41 1.3.6.1.4.1.2007.1.4.72.2.0.41
Notification of Event SRT.41 Message: 'Spanning Tree Explorer sent (RIF $1) from $2 to $3 to port $4, interface $5$6' Parameters list: $1: srt41-RIF $2: srt41-source-mac $3: srt41-dest-mac $4: srt41-port $5: srt41-interface $6: srt41-circuit-name A Spanning Tree Explorer frame has been sent on the specified port.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification42 1.3.6.1.4.1.2007.1.4.72.2.0.42
Notification of Event SRT.42 Message: '$1 Largest Frame size lowered (from $2 bytes to $3 bytes) from $4 to $5 from port $6, interface $7$8' Parameters list: $1: srt42-routing-type $2: srt42-old-LF $3: srt42-new-LF $4: srt42-source-mac $5: srt42-dest-mac $6: srt42-port $7: srt42-interface $8: srt42-circuit-name A source-routing explorer (ARE or STE in routing-type) has had the Largest Frame (LF) field lowered in its RIF. This happens whenever a frame is received from a segment with a smaller maximum frame size than the one presently encoded in the LF bits. This is a normal part of the spanning tree protocol to determine the maximum frame size on all routes.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification43 1.3.6.1.4.1.2007.1.4.72.2.0.43
Notification of Event SRT.43 Message: '$1 Largest Frame size lowered (from $2 bytes to $3 bytes) from $4 to $5 to port $6, interface $7$8' Parameters list: $1: srt43-routing-type $2: srt43-old-LF $3: srt43-new-LF $4: srt43-source-mac $5: srt43-dest-mac $6: srt43-port $7: srt43-interface $8: srt43-circuit-name A source-routing explorer (ARE or STE in routing-type) has had the Largest Frame (LF) field lowered in its RIF. This happens whenever a frame is sent to a segment with a smaller maximum frame size than the one presently encoded in the LF bits. This is a normal part of the spanning tree protocol to determine the maximum frame size on all routes.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification44 1.3.6.1.4.1.2007.1.4.72.2.0.44
Notification of Event SRT.44 Message: 'Specifically-routed frame received (RIF $1) from $2 to $3 from port $4, interface $5$6' Parameters list: $1: srt44-RIF $2: srt44-source-mac $3: srt44-dest-mac $4: srt44-port $5: srt44-interface $6: srt44-circuit-name A Specifically-routed frame has been received on the specified port.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification45 1.3.6.1.4.1.2007.1.4.72.2.0.45
Notification of Event SRT.45 Message: 'Sending Specifically-routed frame (RIF $1) from $2 to $3 to port $4, interface $5$6' Parameters list: $1: srt45-RIF $2: srt45-source-mac $3: srt45-dest-mac $4: srt45-port $5: srt45-interface $6: srt45-circuit-name A Specifically-routed frame is being sent on the specified port.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification46 1.3.6.1.4.1.2007.1.4.72.2.0.46
Notification of Event SRT.46 Message: '$1 frame received from $2 to $3 on disabled port $4, interface $5$6, discarded' Parameters list: $1: srt46-routing-type $2: srt46-source-mac $3: srt46-dest-mac $4: srt46-port $5: srt46-interface $6: srt46-circuit-name A source-routed frame has been received on the specified port, but that port is not configured for bridging. The routing-type is one of SRF (Specifically-routed frame), STE (Spanning Tree Expolorer) or ARE (All Routes Explorer). This really should not happen on more than a transient basis, because ports that are not enabled for bridging should not be queueing packets to the source-routing forwarder.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification47 1.3.6.1.4.1.2007.1.4.72.2.0.47
Notification of Event SRT.47 Message: '$1 frame received from $2 to $3 on non-source-routing port $4, interface $5$6, discarded' Parameters list: $1: srt47-routing-type $2: srt47-source-mac $3: srt47-dest-mac $4: srt47-port $5: srt47-interface $6: srt47-circuit-name A source-routed frame has been received on the specified port, but that port is not configured for source-routing bridging. The routing-type is one of SRF (Specifically-routed frame), STE (Spanning Tree Expolorer) or ARE (All Routes Explorer). This really should not happen on more than a transient basis, because ports that are not enabled for bridging should not be queueing packets to the source-routing forwarder.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification48 1.3.6.1.4.1.2007.1.4.72.2.0.48
Notification of Event SRT.48 Message: 'Spanning Tree Explorer dropped (RIF $1) from $2 to $3 from blocked port $4, interface $5$6' Parameters list: $1: srt48-RIF $2: srt48-source-mac $3: srt48-dest-mac $4: srt48-port $5: srt48-interface $6: srt48-circuit-name A Spanning Tree Explorer (STE) frame was dropped, and not forwarded, because the incoming port is not part of the spanning tree, or has been configured not to forward STE frames.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification49 1.3.6.1.4.1.2007.1.4.72.2.0.49
Notification of Event SRT.49 Message: 'Spanning Tree Explorer not sent (RIF $1) from $2 to $3 to blocked port $4, interface $5$6' Parameters list: $1: srt49-RIF $2: srt49-source-mac $3: srt49-dest-mac $4: srt49-port $5: srt49-interface $6: srt49-circuit-name A Spanning Tree Explorer (STE) frame was not sent on the specified port because it is not part of the spanning tree, or has been configured not to forward STE frames.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification50 1.3.6.1.4.1.2007.1.4.72.2.0.50
Notification of Event SRT.50 Message: 'Got $1 error trying to enable source-routing on interface $2' Parameters list: $1: srt50-error-string $2: srt50-interface The bridge tried to enable source-routing bridging on this interface, but the interface refused the configuration command. Source-routing will be left disabled on this interface.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification51 1.3.6.1.4.1.2007.1.4.72.2.0.51
Notification of Event SRT.51 Message: 'Specifically-routed frame from $1 to $2 is too big (reformatted length $3 > output maximum size $4) for port $5 interface $6$7, dropped' Parameters list: $1: srt51-source-mac $2: srt51-dest-mac $3: srt51-reformatted-length $4: srt51-output-maximum $5: srt51-port $6: srt51-interface $7: srt51-circuit-name The specified Specifically-routed (source-routed) frame is too large to send on this outgoing port and interface. The reformatted-length is the size of the frame including MAC headers after any mapping of data link headers.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification52 1.3.6.1.4.1.2007.1.4.72.2.0.52
Notification of Event SRT.52 Message: '$1 frame from $2 to $3 is too big (reformatted length $4 > output maximum size $5) for port $6 interface $7$8, dropped' Parameters list: $1: srt52-routing-type $2: srt52-source-mac $3: srt52-dest-mac $4: srt52-reformatted-length $5: srt52-output-maximum $6: srt52-port $7: srt52-interface $8: srt52-circuit-name The source-routed explorer (ARE or STE routing-type) frame is too large to send on this outgoing port and interface. The reformatted-length is the size of the frame including MAC headers after any mapping of data link headers.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification53 1.3.6.1.4.1.2007.1.4.72.2.0.53
Notification of Event SRT.53 Message: '$1 with invalid RIF lenth $2 from $3 to $4 from port $5, interface $6$7, discarded' Parameters list: $1: srt53-routing-type $2: srt53-RIF-length $3: srt53-source-mac $4: srt53-dest-mac $5: srt53-port $6: srt53-interface $7: srt53-circuit-name A source-routing frame was received with an invalid RIF length encoded in the Length bits of the RIF. The routing-type is one of SRF (Specifically-routed frame), STE (Spanning Tree Expolorer) or ARE (All Routes Explorer).
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification54 1.3.6.1.4.1.2007.1.4.72.2.0.54
Notification of Event SRT.54 Message: 'No memory for hash table (desired size $1 bytes), disabling bridge' Parameters list: $1: srt54-requested-size There is not enough free memory to allocate the hash table for the filtering database. The bridge will be disabled.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification55 1.3.6.1.4.1.2007.1.4.72.2.0.55
Notification of Event SRT.55 Message: 'No memory for conversion hash table (desired size $1 bytes), disabling bridge' Parameters list: $1: srt55-requested-size There is not enough free memory to allocate the hash table for the conversion database. The bridge will be disabled.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification56 1.3.6.1.4.1.2007.1.4.72.2.0.56
Notification of Event SRT.56 Message: 'Input source-routing queue overflow on frame from $1 to $2, packet dropped from interface $3$4' Parameters list: $1: srt56-source-mac $2: srt56-dest-mac $3: srt56-interface $4: srt56-circuit-name The input queue for source-routed frames to be forwarded is too long, and this frame has been dropped to attempt to alleviate the congestion.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification57 1.3.6.1.4.1.2007.1.4.72.2.0.57
Notification of Event SRT.57 Message: 'Frame from $1 to $2 bridged from port number $3 interface $4$5 to port number $6 interface $7$8' Parameters list: $1: srt57-source-mac $2: srt57-dest-mac $3: srt57-port $4: srt57-interface $5: srt57-circuit-name $6: srt57-out-port $7: srt57-out-interface $8: srt57-out-circuit-name A frame is being bridged between these two interfaces. The destination address was known, so it was sent only to the correct destination network.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification58 1.3.6.1.4.1.2007.1.4.72.2.0.58
Notification of Event SRT.58 Message: 'Transparent frame converted to source-routed frame from $1 to $2 is too big (reformatted length $3 bytes > output maximum size $4 bytes) for port $5 interface $6$7, dropped' Parameters list: $1: srt58-source-mac $2: srt58-dest-mac $3: srt58-reformatted-length $4: srt58-output-maximum $5: srt58-port $6: srt58-interface $7: srt58-circuit-name The specified transparent bridge frame is too large to send as a source-routed frame on this outgoing port and interface. The reformatted-length is the size of the frame including MAC headers and RIF after any mapping of data link headers.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification59 1.3.6.1.4.1.2007.1.4.72.2.0.59
Notification of Event SRT.59 Message: 'Transparent frame converted to source-routed frame from $1 to $2 (RIF $3) bridged from port number $4 interface $5$6 to port number $7 interface $8$9' Parameters list: $1: srt59-source-mac $2: srt59-dest-mac $3: srt59-RIF $4: srt59-port $5: srt59-interface $6: srt59-circuit-name $7: srt59-out-port $8: srt59-out-interface $9: srt59-out-circuit-name A frame is being conversion bridged between these two interfaces. The destination address and RIF were known, so it was sent only to the correct destination network.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification60 1.3.6.1.4.1.2007.1.4.72.2.0.60
Notification of Event SRT.60 Message: 'Transparent frame converted to source-routed frame from $1 to $2 (RIF $3$4) bridged to all ports from port number $5 interface $6$7 to port number $8 interface $9$10' Parameters list: $1: srt60-source-mac $2: srt60-dest-mac $3: srt60-RIF $4: srt60-RIF $5: srt60-port $6: srt60-interface $7: srt60-circuit-name $8: srt60-out-port $9: srt60-out-interface $10: srt60-out-circuit-name A frame is being conversion bridged to all active source-routing ports. This happens when the frame destination is a multicast or when the frame destination is not in the source-routing learning database. There will be one message for each port the frame is sent on.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification61 1.3.6.1.4.1.2007.1.4.72.2.0.61
Notification of Event SRT.61 Message: 'Specifically routed frame received from $1 to $2 (RIF $3) to disabled port $4, interface $5$6, discarded' Parameters list: $1: srt61-source-mac $2: srt61-dest-mac $3: srt61-RIF $4: srt61-port $5: srt61-interface $6: srt61-circuit-name A Specifically Routed frame has been received whose RIF would send it on the specified port, but that port is not configured for bridging.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification62 1.3.6.1.4.1.2007.1.4.72.2.0.62
Notification of Event SRT.62 Message: 'Source-routed frame converted to transparent frame from $1 to $2 is too big (reformatted length $3 bytes > output maximum size $4 bytes) from port $5 interface $6$7, may get dropped' Parameters list: $1: srt62-source-mac $2: srt62-dest-mac $3: srt62-reformatted-length $4: srt62-output-maximum $5: srt62-port $6: srt62-interface $7: srt62-circuit-name The specified source-routed frame is larger than that is allowed by LF-BIT configuration for the transparent bridge domain. After mapping to the MAC headers of the outgoing port, the packet may get dropped if it exceeds the MSDU limit of the port.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification63 1.3.6.1.4.1.2007.1.4.72.2.0.63
Notification of Event SRT.63 Message: 'No buffer available to duplicate $1 frame from $2 to $3 for source-routing to transparent bridging conversion from port $4 interface $5$6' Parameters list: $1: srt63-routing-type $2: srt63-source-mac $3: srt63-dest-mac $4: srt63-port $5: srt63-interface $6: srt63-circuit-name No buffer available to copy a frame in order to send Routes Explorer (ARE) or Spanning Tree Explorer (STE) routing-type frame out as a transparent bridged frame in the transparent bridging domain. No copy of this frame will be sent into the transparent bridge domain.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification64 1.3.6.1.4.1.2007.1.4.72.2.0.64
Notification of Event SRT.64 Message: 'No memory for conversion database (desired size $1 bytes), disabling bridge' Parameters list: $1: srt64-requested-size There is not enough free memory to allocate even a minimal size conversion database. The bridge will be disabled.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification65 1.3.6.1.4.1.2007.1.4.72.2.0.65
Notification of Event SRT.65 Message: 'Cannot add static entry for address $1 on interface $2' Parameters list: $1: srt65-MAC-address $2: srt65-interface An attempt to add a particular static entry to the internal database of a bridging interface having internal filtering failed.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification66 1.3.6.1.4.1.2007.1.4.72.2.0.66
Notification of Event SRT.66 Message: 'Cannot enable transparent bridging on interface $1$2' Parameters list: $1: srt66-interface $2: srt66-circuit-name The bridge has been configured to enable transparent bridging on an IEEE 802.5 Token-Ring interface that does not have the hardware to support transparent bridging. Transparent bridging will not be enabled on this interface.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification67 1.3.6.1.4.1.2007.1.4.72.2.0.67
Notification of Event SRT.67 Message: 'Specifically routed frame frame from $1 to $2 (RIF $3) forwarded to disabled port $4, interface $5$6, discarded' Parameters list: $1: srt67-source-mac $2: srt67-dest-mac $3: srt67-RIF $4: srt67-port $5: srt67-interface $6: srt67-circuit-name A Specifically Routed frame has been sent on a port, but that port is not configured for bridging. This should never happen, since prior checks should prevent calling this code if the port is not configured for bridging.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification68 1.3.6.1.4.1.2007.1.4.72.2.0.68
Notification of Event SRT.68 Message: 'Ethernet type table full for Ethernet type $1' Parameters list: $1: srt68-ethernet-type There is no space in the Ethernet type registration table for the specified ethernet-type. This happens when there are too many hash collisions, and there are not enough overflow buckets.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification69 1.3.6.1.4.1.2007.1.4.72.2.0.69
Notification of Event SRT.69 Message: 'Subnetwork Access Protocol table full for Protocol Identifier type $1-$2-$3-$4-$5' Parameters list: $1: srt69-protocol $2: srt69-protocol $3: srt69-protocol $4: srt69-protocol $5: srt69-protocol There is no space in the SNAP PID registration table for the specified protocol. This happens when there are too many hash collisions, and there are not enough overflow buckets.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification70 1.3.6.1.4.1.2007.1.4.72.2.0.70
Notification of Event SRT.70 Message: 'Frame from $1 to $2 dropped, destination address filtered, port $3 interface $4$5' Parameters list: $1: srt70-source-mac $2: srt70-dest-mac $3: srt70-port $4: srt70-interface $5: srt70-circuit-name A MAC frame has been received by the hardware, but is being dropped because the destination MAC address is being administratively filtered by the bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification71 1.3.6.1.4.1.2007.1.4.72.2.0.71
Notification of Event SRT.71 Message: 'Source Routing not supported on port $1, interface $2$3' Parameters list: $1: srt71-port $2: srt71-interface $3: srt71-circuit-name Source Routing is configured on the port which is attached to an underlying network which inherently does not support source routing type of functionalities. Such networks are Ethernet and FDDI. Bridge disables source routing on the port.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification72 1.3.6.1.4.1.2007.1.4.72.2.0.72
Notification of Event SRT.72 Message: 'Conversion bridging (Adaptive or SR-TB) enabled, but not licensed, disabling' Conversion bridging has been enabled, but that feature was not purchased as part of this software load. The conversion bridging feature will not be enabled.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification73 1.3.6.1.4.1.2007.1.4.72.2.0.73
Notification of Event SRT.73 Message: 'Source-routing bridging enabled, but not licensed, disabling' Source-routing bridging has been enabled, but that feature was not purchased as part of this software load. The source-routing bridging feature will not be enabled.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification74 1.3.6.1.4.1.2007.1.4.72.2.0.74
Notification of Event SRT.74 Message: 'Source-routing bridging enabled on interface $1$2, but not licensed, disabling' Parameters list: $1: srt74-interface $2: srt74-circuit-name Source-routing bridging has been enabled, but that feature was not purchased as part of this software load. The source-routing bridging feature will not be enabled.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification75 1.3.6.1.4.1.2007.1.4.72.2.0.75
Notification of Event SRT.75 Message: 'Spanning tree (transparent) bridging enabled on interface $1$2, but not licensed, disabling' Parameters list: $1: srt75-interface $2: srt75-circuit-name Spanning tree (transparent) bridging has been enabled, but that feature was not purchased as part of this software load. The spanning tree (transparent) bridging feature will not be enabled.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification76 1.3.6.1.4.1.2007.1.4.72.2.0.76
Notification of Event SRT.76 Message: 'No memory to allocate a NETBIOS Filter' At least one configured NETBIOS Filter will not be enabled, because there is not enough memory.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification77 1.3.6.1.4.1.2007.1.4.72.2.0.77
Notification of Event SRT.77 Message: '$1 NETBIOS filter list, for port $2, deleted by user. Filter will not be enabled' Parameters list: $1: srt77-input-output $2: srt77-port-number The user deleted a filter list, which was part of an already configured filter. The filter will not be enabled.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification78 1.3.6.1.4.1.2007.1.4.72.2.0.78
Notification of Event SRT.78 Message: '$1 NETBIOS filter for port $2 is configured, but that port number is not configured' Parameters list: $1: srt78-input-output $2: srt78-port-number The user configured a NETBIOS filter for a particular port, but that port number is not configured.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification79 1.3.6.1.4.1.2007.1.4.72.2.0.79
Notification of Event SRT.79 Message: 'NETBIOS Output Packet Filtered - $1->$2, port $3, interface $4$5' Parameters list: $1: srt79-source-mac $2: srt79-dest-mac $3: srt79-port $4: srt79-interface $5: srt79-circuit-name A NETBIOS packet has matched the criteria specified in a NETBIOS Filter configuration record. The packet is dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification80 1.3.6.1.4.1.2007.1.4.72.2.0.80
Notification of Event SRT.80 Message: 'No memory to allocate information for NETBIOS Filter console display' The part of the router that handles NETBIOS console display cannot allocate enough memory to do the complete display. Some part of the NETBIOS console display will not be shown from the T 5 process.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification81 1.3.6.1.4.1.2007.1.4.72.2.0.81
Notification of Event SRT.81 Message: 'NETBIOS STE converted to SRF (RIF $1) $2->$3 from port $4' Parameters list: $1: srt81-RIF $2: srt81-source-mac $3: srt81-dest-mac $4: srt81-port A NETBIOS STE converted to SRF by NETBIOS Name Caching.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification82 1.3.6.1.4.1.2007.1.4.72.2.0.82
Notification of Event SRT.82 Message: 'NETBIOS STE not converted, RIF too long' NETBIOS STE not converted, RIF too long.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification83 1.3.6.1.4.1.2007.1.4.72.2.0.83
Notification of Event SRT.83 Message: 'NETBIOS find-name STE filtered (RIF $1) $2->$3 from port $4' Parameters list: $1: srt83-RIF $2: srt83-source-mac $3: srt83-dest-mac $4: srt83-port A NETBIOS find-name STE has been filtered.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification84 1.3.6.1.4.1.2007.1.4.72.2.0.84
Notification of Event SRT.84 Message: 'BPDU dropped because STP disabled on port $1, interface $2' Parameters list: $1: srt84-port $2: srt84-interface A spanning tree BPDU frame was received on a port that has been disabled for spanning tree participation by the 'disable tree port#' command.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification85 1.3.6.1.4.1.2007.1.4.72.2.0.85
Notification of Event SRT.85 Message: 'Frame relay Port $1 configured on non-Frame relay interface $2' Parameters list: $1: srt85-port $2: srt85-interface-number The port has been configured to use a Frame Relay interface. However, subsequent to bridge configuration, device configuration changed such that the device is no longer configured to be a Frame Relay device. This could have happened if the user changed the data link support on the device, or re-ordered the device records.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification86 1.3.6.1.4.1.2007.1.4.72.2.0.86
Notification of Event SRT.86 Message: 'Bridge port $1 with circuit=$2 registration with interface $3 failed, reason=$4' Parameters list: $1: srt86-port $2: srt86-circuit-name $3: srt86-interface $4: srt86-reason During bridge initialization, ports are associated with Frame Relay registers with the Frame Relay interface. During registration, both let each other know about their existence and exchange some useful information to keep about each other.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification87 1.3.6.1.4.1.2007.1.4.72.2.0.87
Notification of Event SRT.87 Message: 'All Routes Explorer exceeds maximum Route Descriptors from $1 to $2 from port $3, interface $4$5' Parameters list: $1: srt87-source-mac $2: srt87-dest-mac $3: srt87-port $4: srt87-interface $5: srt87-circuit-name An All Routes Explorer (ARE) source-routed frame has more Route Descriptors than this bridge is configured to allow for ARE frames. The frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification88 1.3.6.1.4.1.2007.1.4.72.2.0.88
Notification of Event SRT.88 Message: 'Cannot autoconfigure the bridge address, there is no available MAC address' The user has configured the bridge to autoconfigure the bridge address. However, there is no port with a configured MAC address and it is no possible to get one from BIOS.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification89 1.3.6.1.4.1.2007.1.4.72.2.0.89
Notification of Event SRT.89 Message: 'Frame from $1 to $2 bridged from port number $3 interface $4$5 to port number $6 interface $7$8' Parameters list: $1: srt89-source-mac $2: srt89-dest-mac $3: srt89-port $4: srt89-interface $5: srt89-circuit-name $6: srt89-out-port $7: srt89-out-interface $8: srt89-out-circuit-name A frame is being bridged between these two interfaces. The destination address was broadcast or unregistered.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

srtNotification90 1.3.6.1.4.1.2007.1.4.72.2.0.90
Notification of Event SRT.90 Message: 'Frame from $1 to $2 for vlan $3 not bridged because vlan bridging is disabled' Parameters list: $1: srt90-source-mac $2: srt90-dest-mac $3: srt90-vid A VLAN tagged frame on a ethernet subinterface was received but bridging is disabled for vlans. The frame will not be bridged.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE