TELDAT-TRAP-SL-MIB

File: TELDAT-TRAP-SL-MIB.mib (46628 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC TELDAT-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE OBJECT-IDENTITY
NOTIFICATION-TYPE Integer32 IpAddress
DisplayString telEventTraps

Defined Values

slTrapsMIB 1.3.6.1.4.1.2007.1.4.83
This Module Information Base file is defined for managing received SNMP notifications generated by the SL event subsystem.
MODULE-IDENTITY    

slEventsGroup 1.3.6.1.4.1.2007.1.4.83.1
OBJECT IDENTIFIER    

slNotifications 1.3.6.1.4.1.2007.1.4.83.2
OBJECT IDENTIFIER    

slNotificationsPrefix 1.3.6.1.4.1.2007.1.4.83.2.0
OBJECT IDENTIFIER    

slEventObjects1 1.3.6.1.4.1.2007.1.4.83.1.1
Event SL.1 A packet buffer was not available when the interface self-test needed one.
Status: current Access: read-write
OBJECT-IDENTITY    

sl1-interface 1.3.6.1.4.1.2007.1.4.83.1.1.1
Parameter 'interface' in event SL.1
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects2 1.3.6.1.4.1.2007.1.4.83.1.2
Event SL.2 During the self-test, the interface card detected that certain signals from modem necessary to indicate that it is present and ready to operate were not detectable.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl2-interface 1.3.6.1.4.1.2007.1.4.83.1.2.1
Parameter 'interface' in event SL.2
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects3 1.3.6.1.4.1.2007.1.4.83.1.3
Event SL.3 During self-test, an Echo Acknowledgement was not received from the other end of the line within the timeout period. The network fails self-test.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl3-interface 1.3.6.1.4.1.2007.1.4.83.1.3.1
Parameter 'interface' in event SL.3
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects4 1.3.6.1.4.1.2007.1.4.83.1.4
Event SL.4 A bad length field or truncated packet was detected in a DECnet packet on the serial line.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl4-actual-length 1.3.6.1.4.1.2007.1.4.83.1.4.1
Parameter 'actual-length' in event SL.4
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

sl4-claimed-length 1.3.6.1.4.1.2007.1.4.83.1.4.2
Parameter 'claimed-length' in event SL.4
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

sl4-interface 1.3.6.1.4.1.2007.1.4.83.1.4.3
Parameter 'interface' in event SL.4
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects5 1.3.6.1.4.1.2007.1.4.83.1.5
Event SL.5 A network control packet was received with a packet type which did not match any known opcode.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl5-opcode 1.3.6.1.4.1.2007.1.4.83.1.5.1
Parameter 'opcode' in event SL.5
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

sl5-interface 1.3.6.1.4.1.2007.1.4.83.1.5.2
Parameter 'interface' in event SL.5
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects6 1.3.6.1.4.1.2007.1.4.83.1.6
Event SL.6 A serial line packet was received with a higher level protocol which did not match any known protocol.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl6-protocol 1.3.6.1.4.1.2007.1.4.83.1.6.1
Parameter 'protocol' in event SL.6
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

sl6-interface 1.3.6.1.4.1.2007.1.4.83.1.6.2
Parameter 'interface' in event SL.6
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects7 1.3.6.1.4.1.2007.1.4.83.1.7
Event SL.7 Self-test is being started on the serial line.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl7-interface 1.3.6.1.4.1.2007.1.4.83.1.7.1
Parameter 'interface' in event SL.7
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects8 1.3.6.1.4.1.2007.1.4.83.1.8
Event SL.8 An echo request is being sent on the serial line.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl8-interface 1.3.6.1.4.1.2007.1.4.83.1.8.1
Parameter 'interface' in event SL.8
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects9 1.3.6.1.4.1.2007.1.4.83.1.9
Event SL.9 A test packet has been received on the serial line.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl9-interface 1.3.6.1.4.1.2007.1.4.83.1.9.1
Parameter 'interface' in event SL.9
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects10 1.3.6.1.4.1.2007.1.4.83.1.10
Event SL.10 An echo acknowledgement packet has been received on the serial line.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl10-interface 1.3.6.1.4.1.2007.1.4.83.1.10.1
Parameter 'interface' in event SL.10
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects11 1.3.6.1.4.1.2007.1.4.83.1.11
Event SL.11 An echo acknowledgement packet has been received on the serial line.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl11-interface 1.3.6.1.4.1.2007.1.4.83.1.11.1
Parameter 'interface' in event SL.11
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects12 1.3.6.1.4.1.2007.1.4.83.1.12
Event SL.12 A test packet used for network maintenence is being sent on the serial line.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl12-interface 1.3.6.1.4.1.2007.1.4.83.1.12.1
Parameter 'interface' in event SL.12
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects13 1.3.6.1.4.1.2007.1.4.83.1.13
Event SL.13 A Bridged packet is received on this serial line interface even though the Spanning Tree Bridging is not enabled on this interface or STB is disabled in the box.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl13-interface 1.3.6.1.4.1.2007.1.4.83.1.13.1
Parameter 'interface' in event SL.13
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects14 1.3.6.1.4.1.2007.1.4.83.1.14
Event SL.14 Dual Serial Line Interface board firmware download has completed with the status shown.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl14-slot-num 1.3.6.1.4.1.2007.1.4.83.1.14.1
Parameter 'slot-num' in event SL.14
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

sl14-ld-code 1.3.6.1.4.1.2007.1.4.83.1.14.2
Parameter 'ld-code' in event SL.14
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects15 1.3.6.1.4.1.2007.1.4.83.1.15
Event SL.15 Dual Serial Line Board Power-On Diagnostics status completed with the code shown. See Power-On Diagnostics manual for encoding.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl15-slot-num 1.3.6.1.4.1.2007.1.4.83.1.15.1
Parameter 'slot-num' in event SL.15
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

sl15-pud-stat 1.3.6.1.4.1.2007.1.4.83.1.15.2
Parameter 'pud-stat' in event SL.15
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

slEventObjects16 1.3.6.1.4.1.2007.1.4.83.1.16
Event SL.16 Protocol type like Ethertype, DSAPytype or SNAPtype packet filtered. This is due to the user supplied protocol filtering information. (STB).
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl16-protocol-type 1.3.6.1.4.1.2007.1.4.83.1.16.1
Parameter 'protocol-type' in event SL.16
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

sl16-protocol 1.3.6.1.4.1.2007.1.4.83.1.16.2
Parameter 'protocol' in event SL.16
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

sl16-interface 1.3.6.1.4.1.2007.1.4.83.1.16.3
Parameter 'interface' in event SL.16
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects17 1.3.6.1.4.1.2007.1.4.83.1.17
Event SL.17 Packet dropped as the protocol type is enabled but packet arrived as bridged. (STB).
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl17-protocol-type 1.3.6.1.4.1.2007.1.4.83.1.17.1
Parameter 'protocol-type' in event SL.17
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

sl17-src-addr 1.3.6.1.4.1.2007.1.4.83.1.17.2
Parameter 'src-addr' in event SL.17
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

sl17-interface 1.3.6.1.4.1.2007.1.4.83.1.17.3
Parameter 'interface' in event SL.17
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects18 1.3.6.1.4.1.2007.1.4.83.1.18
Event SL.18 Packet dropped as the protocol filtering applies (STB).
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl18-protocol-type 1.3.6.1.4.1.2007.1.4.83.1.18.1
Parameter 'protocol-type' in event SL.18
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

sl18-interface 1.3.6.1.4.1.2007.1.4.83.1.18.2
Parameter 'interface' in event SL.18
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects19 1.3.6.1.4.1.2007.1.4.83.1.19
Event SL.19 The cable and the level converter on the interface are not compatible with each other. The self-test will fail.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl19-cable-type 1.3.6.1.4.1.2007.1.4.83.1.19.1
Parameter 'cable-type' in event SL.19
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

sl19-level-converter-type 1.3.6.1.4.1.2007.1.4.83.1.19.2
Parameter 'level-converter-type' in event SL.19
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

sl19-interface 1.3.6.1.4.1.2007.1.4.83.1.19.3
Parameter 'interface' in event SL.19
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects20 1.3.6.1.4.1.2007.1.4.83.1.20
Event SL.20 There is an incompatibility between the mode of the cable (DCE or DTE) and the type of clocking used. The interface will not be brought up.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl20-cable-type 1.3.6.1.4.1.2007.1.4.83.1.20.1
Parameter 'cable-type' in event SL.20
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

sl20-internal-external 1.3.6.1.4.1.2007.1.4.83.1.20.2
Parameter 'internal-external' in event SL.20
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

sl20-interface 1.3.6.1.4.1.2007.1.4.83.1.20.3
Parameter 'interface' in event SL.20
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects21 1.3.6.1.4.1.2007.1.4.83.1.21
Event SL.21 The interface failed self test because at least one of the modem signals was off.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl21-cts 1.3.6.1.4.1.2007.1.4.83.1.21.1
Parameter 'cts' in event SL.21
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

sl21-dsr 1.3.6.1.4.1.2007.1.4.83.1.21.2
Parameter 'dsr' in event SL.21
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

sl21-dcd 1.3.6.1.4.1.2007.1.4.83.1.21.3
Parameter 'dcd' in event SL.21
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

sl21-interface 1.3.6.1.4.1.2007.1.4.83.1.21.4
Parameter 'interface' in event SL.21
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects22 1.3.6.1.4.1.2007.1.4.83.1.22
Event SL.22 A modem status change has occurred. The present state is described.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl22-cts 1.3.6.1.4.1.2007.1.4.83.1.22.1
Parameter 'cts' in event SL.22
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

sl22-dsr 1.3.6.1.4.1.2007.1.4.83.1.22.2
Parameter 'dsr' in event SL.22
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

sl22-dcd 1.3.6.1.4.1.2007.1.4.83.1.22.3
Parameter 'dcd' in event SL.22
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

sl22-interface 1.3.6.1.4.1.2007.1.4.83.1.22.4
Parameter 'interface' in event SL.22
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects23 1.3.6.1.4.1.2007.1.4.83.1.23
Event SL.23 The interface was brought down because one of the modem signals was off.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl23-cts 1.3.6.1.4.1.2007.1.4.83.1.23.1
Parameter 'cts' in event SL.23
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

sl23-dsr 1.3.6.1.4.1.2007.1.4.83.1.23.2
Parameter 'dsr' in event SL.23
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

sl23-dcd 1.3.6.1.4.1.2007.1.4.83.1.23.3
Parameter 'dcd' in event SL.23
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

sl23-interface 1.3.6.1.4.1.2007.1.4.83.1.23.4
Parameter 'interface' in event SL.23
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects24 1.3.6.1.4.1.2007.1.4.83.1.24
Event SL.24 The user-configured frame size for this interface is larger than the maximum that is allowed for the particular serial line device. The size is reduced to the largest allowable one.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl24-configured-size 1.3.6.1.4.1.2007.1.4.83.1.24.1
Parameter 'configured-size' in event SL.24
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

sl24-maximum-size 1.3.6.1.4.1.2007.1.4.83.1.24.2
Parameter 'maximum-size' in event SL.24
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

sl24-interface 1.3.6.1.4.1.2007.1.4.83.1.24.3
Parameter 'interface' in event SL.24
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects25 1.3.6.1.4.1.2007.1.4.83.1.25
Event SL.25 A bad length field or truncated packet was detected in a SRT bridge packet.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl25-actual-length 1.3.6.1.4.1.2007.1.4.83.1.25.1
Parameter 'actual-length' in event SL.25
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

sl25-claimed-length 1.3.6.1.4.1.2007.1.4.83.1.25.2
Parameter 'claimed-length' in event SL.25
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

sl25-interface 1.3.6.1.4.1.2007.1.4.83.1.25.3
Parameter 'interface' in event SL.25
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects26 1.3.6.1.4.1.2007.1.4.83.1.26
Event SL.26 An Incoming Serial Line packet is shorter than a minimally required Serial Line header. Such packet can not be processed and hence freed.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl26-actual-length 1.3.6.1.4.1.2007.1.4.83.1.26.1
Parameter 'actual-length' in event SL.26
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

sl26-interface 1.3.6.1.4.1.2007.1.4.83.1.26.2
Parameter 'interface' in event SL.26
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects27 1.3.6.1.4.1.2007.1.4.83.1.27
Event SL.27 There is no level converter on this port of the Quad Serial Line card. The self-test will fail, and future self-tests will be cancelled.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl27-interface 1.3.6.1.4.1.2007.1.4.83.1.27.1
Parameter 'interface' in event SL.27
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects28 1.3.6.1.4.1.2007.1.4.83.1.28
Event SL.28 There is a level converter of an unknown type on this port of the Quad Serial Line card. The self-test will fail, and future self-tests will be cancelled.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl28-converter-type 1.3.6.1.4.1.2007.1.4.83.1.28.1
Parameter 'converter-type' in event SL.28
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

sl28-interface 1.3.6.1.4.1.2007.1.4.83.1.28.2
Parameter 'interface' in event SL.28
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects29 1.3.6.1.4.1.2007.1.4.83.1.29
Event SL.29 The user-configured frame size for this interface is smaller than the minimum that is required for the particular serial line device. The size is increased to the minimum allowable one.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl29-configured-size 1.3.6.1.4.1.2007.1.4.83.1.29.1
Parameter 'configured-size' in event SL.29
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

sl29-minimum-size 1.3.6.1.4.1.2007.1.4.83.1.29.2
Parameter 'minimum-size' in event SL.29
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

sl29-interface 1.3.6.1.4.1.2007.1.4.83.1.29.3
Parameter 'interface' in event SL.29
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects30 1.3.6.1.4.1.2007.1.4.83.1.30
Event SL.30 The maintenance routine is attempting to send a maintenance frame for Proteon Serial data-link, but the buffer for sending this has not been freed since the previous maintenance. If this happens 3 times in a row, maintenance will fail at the other end of the serial line.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl30-interface 1.3.6.1.4.1.2007.1.4.83.1.30.1
Parameter 'interface' in event SL.30
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects31 1.3.6.1.4.1.2007.1.4.83.1.31
Event SL.31 A buffer could not be allocated when needed to read the statistics counters from the Dual Serial interface. The counters should be successfully updated at the next maintenance, 4 seconds later.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl31-interface 1.3.6.1.4.1.2007.1.4.83.1.31.1
Parameter 'interface' in event SL.31
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects32 1.3.6.1.4.1.2007.1.4.83.1.32
Event SL.32 The allocation of a packet buffer for a DNX 300 serial line failed. This may be due to a shortage of either buffer memory or heap memory. (See the output of ELS messages GW.061, GW.063, and GW.064). The interface will still try and come up, but with a reduced number of receive packet buffers.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl32-buffer-number 1.3.6.1.4.1.2007.1.4.83.1.32.1
Parameter 'buffer-number' in event SL.32
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

sl32-interface 1.3.6.1.4.1.2007.1.4.83.1.32.2
Parameter 'interface' in event SL.32
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects33 1.3.6.1.4.1.2007.1.4.83.1.33
Event SL.33 A packet buffer was allocated for the DNX 300 serial line, but that buffer crossed a 64 Kbyte memory boundary in the buffer memory. Since all of the receive buffers for a DNX 300 serial line must be in the same 64 Kbyte buffer memory packet, that buffer will be ignored, and no further buffers will be allocated for the device. The interface will still try and come up, but with a reduced number of receive packet buffers.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl33-buffer-number 1.3.6.1.4.1.2007.1.4.83.1.33.1
Parameter 'buffer-number' in event SL.33
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

sl33-interface 1.3.6.1.4.1.2007.1.4.83.1.33.2
Parameter 'interface' in event SL.33
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects34 1.3.6.1.4.1.2007.1.4.83.1.34
Event SL.34 The system does not detect an adapter cable in the network interface port. Self-test will fail.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl34-interface 1.3.6.1.4.1.2007.1.4.83.1.34.1
Parameter 'interface' in event SL.34
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects35 1.3.6.1.4.1.2007.1.4.83.1.35
Event SL.35 A protocol that cannot be bridged by Proteon Serial Line's PSEUDO- ETHERNET bridging method has been configured over an interface using PSL PSEUDO-ETH.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl35-protocol-name 1.3.6.1.4.1.2007.1.4.83.1.35.1
Parameter 'protocol-name' in event SL.35
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

sl35-protocol-number 1.3.6.1.4.1.2007.1.4.83.1.35.2
Parameter 'protocol-number' in event SL.35
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

sl35-interface 1.3.6.1.4.1.2007.1.4.83.1.35.3
Parameter 'interface' in event SL.35
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slEventObjects36 1.3.6.1.4.1.2007.1.4.83.1.36
Event SL.36 The interface is on mode loopback or echo and the timeout as expired.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

sl36-interface 1.3.6.1.4.1.2007.1.4.83.1.36.1
Parameter 'interface' in event SL.36
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

slNotification1 1.3.6.1.4.1.2007.1.4.83.2.0.1
Notification of Event SL.1 Message: 'no buffer available for selftest interface $1' Parameters list: $1: sl1-interface A packet buffer was not available when the interface self-test needed one.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification2 1.3.6.1.4.1.2007.1.4.83.2.0.2
Notification of Event SL.2 Message: 'modem error with no DCD/DTS detected during selftest interface $1' Parameters list: $1: sl2-interface During the self-test, the interface card detected that certain signals from modem necessary to indicate that it is present and ready to operate were not detectable.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification3 1.3.6.1.4.1.2007.1.4.83.2.0.3
Notification of Event SL.3 Message: 'no echo acknowledgement received, timeout selftest interface $1' Parameters list: $1: sl3-interface During self-test, an Echo Acknowledgement was not received from the other end of the line within the timeout period. The network fails self-test.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification4 1.3.6.1.4.1.2007.1.4.83.2.0.4
Notification of Event SL.4 Message: 'bad length in DECNet packet actual $1 claimed $2 interface $3' Parameters list: $1: sl4-actual-length $2: sl4-claimed-length $3: sl4-interface A bad length field or truncated packet was detected in a DECnet packet on the serial line.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification5 1.3.6.1.4.1.2007.1.4.83.2.0.5
Notification of Event SL.5 Message: 'bad received packet header opcode $1 interface $2' Parameters list: $1: sl5-opcode $2: sl5-interface A network control packet was received with a packet type which did not match any known opcode.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification6 1.3.6.1.4.1.2007.1.4.83.2.0.6
Notification of Event SL.6 Message: 'bad received packet header protocol $1 interface $2' Parameters list: $1: sl6-protocol $2: sl6-interface A serial line packet was received with a higher level protocol which did not match any known protocol.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification7 1.3.6.1.4.1.2007.1.4.83.2.0.7
Notification of Event SL.7 Message: 'start selftest interface $1' Parameters list: $1: sl7-interface Self-test is being started on the serial line.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification8 1.3.6.1.4.1.2007.1.4.83.2.0.8
Notification of Event SL.8 Message: 'send echo packet interface $1' Parameters list: $1: sl8-interface An echo request is being sent on the serial line.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification9 1.3.6.1.4.1.2007.1.4.83.2.0.9
Notification of Event SL.9 Message: 'receive test packet interface $1' Parameters list: $1: sl9-interface A test packet has been received on the serial line.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification10 1.3.6.1.4.1.2007.1.4.83.2.0.10
Notification of Event SL.10 Message: 'receive echo acknowledgement packet interface $1' Parameters list: $1: sl10-interface An echo acknowledgement packet has been received on the serial line.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification11 1.3.6.1.4.1.2007.1.4.83.2.0.11
Notification of Event SL.11 Message: 'receive echo request packet interface $1' Parameters list: $1: sl11-interface An echo acknowledgement packet has been received on the serial line.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification12 1.3.6.1.4.1.2007.1.4.83.2.0.12
Notification of Event SL.12 Message: 'sending maintenance test packet interface $1' Parameters list: $1: sl12-interface A test packet used for network maintenence is being sent on the serial line.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification13 1.3.6.1.4.1.2007.1.4.83.2.0.13
Notification of Event SL.13 Message: 'Dropping the received Spanning Tree Bridged packet but bridging is disabled on interface $1' Parameters list: $1: sl13-interface A Bridged packet is received on this serial line interface even though the Spanning Tree Bridging is not enabled on this interface or STB is disabled in the box.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification14 1.3.6.1.4.1.2007.1.4.83.2.0.14
Notification of Event SL.14 Message: 'Dual Serial Line board in slot $1 firmware download $2' Parameters list: $1: sl14-slot-num $2: sl14-ld-code Dual Serial Line Interface board firmware download has completed with the status shown.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification15 1.3.6.1.4.1.2007.1.4.83.2.0.15
Notification of Event SL.15 Message: 'Dual Serial Line board slot $1 Power-On Diagnostics status $2' Parameters list: $1: sl15-slot-num $2: sl15-pud-stat Dual Serial Line Board Power-On Diagnostics status completed with the code shown. See Power-On Diagnostics manual for encoding.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification16 1.3.6.1.4.1.2007.1.4.83.2.0.16
Notification of Event SL.16 Message: '$1 type pakcet filtered for protocol = $2 interface $3' Parameters list: $1: sl16-protocol-type $2: sl16-protocol $3: sl16-interface Protocol type like Ethertype, DSAPytype or SNAPtype packet filtered. This is due to the user supplied protocol filtering information. (STB).
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification17 1.3.6.1.4.1.2007.1.4.83.2.0.17
Notification of Event SL.17 Message: 'Dropped, protocol = $1 enabled but packet arrived as bridged from address $2, interface $3' Parameters list: $1: sl17-protocol-type $2: sl17-src-addr $3: sl17-interface Packet dropped as the protocol type is enabled but packet arrived as bridged. (STB).
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification18 1.3.6.1.4.1.2007.1.4.83.2.0.18
Notification of Event SL.18 Message: 'Dropped, dsap = $1, Protocol filtreing applies, interface $2' Parameters list: $1: sl18-protocol-type $2: sl18-interface Packet dropped as the protocol filtering applies (STB).
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification19 1.3.6.1.4.1.2007.1.4.83.2.0.19
Notification of Event SL.19 Message: 'Cable of type $1 is not compatible with level converter of type $2, interface $3' Parameters list: $1: sl19-cable-type $2: sl19-level-converter-type $3: sl19-interface The cable and the level converter on the interface are not compatible with each other. The self-test will fail.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification20 1.3.6.1.4.1.2007.1.4.83.2.0.20
Notification of Event SL.20 Message: '$1 cable cannot be used with $2 clocking enabled, interface $3' Parameters list: $1: sl20-cable-type $2: sl20-internal-external $3: sl20-interface There is an incompatibility between the mode of the cable (DCE or DTE) and the type of clocking used. The interface will not be brought up.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification21 1.3.6.1.4.1.2007.1.4.83.2.0.21
Notification of Event SL.21 Message: 'Self test failed because of modem status, CTS = $1, DSR = $2, DCD = $3, ifc $4' Parameters list: $1: sl21-cts $2: sl21-dsr $3: sl21-dcd $4: sl21-interface The interface failed self test because at least one of the modem signals was off.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification22 1.3.6.1.4.1.2007.1.4.83.2.0.22
Notification of Event SL.22 Message: 'Modem status change CTS = $1, DSR = $2, DCD = $3, on interface $4' Parameters list: $1: sl22-cts $2: sl22-dsr $3: sl22-dcd $4: sl22-interface A modem status change has occurred. The present state is described.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification23 1.3.6.1.4.1.2007.1.4.83.2.0.23
Notification of Event SL.23 Message: 'Interface down because of modem status, CTS = $1, DSR = $2, DCD = $3, ifc $4' Parameters list: $1: sl23-cts $2: sl23-dsr $3: sl23-dcd $4: sl23-interface The interface was brought down because one of the modem signals was off.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification24 1.3.6.1.4.1.2007.1.4.83.2.0.24
Notification of Event SL.24 Message: 'Configured frame size of $1 bytes too large, reducing to $2 bytes, interface $3' Parameters list: $1: sl24-configured-size $2: sl24-maximum-size $3: sl24-interface The user-configured frame size for this interface is larger than the maximum that is allowed for the particular serial line device. The size is reduced to the largest allowable one.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification25 1.3.6.1.4.1.2007.1.4.83.2.0.25
Notification of Event SL.25 Message: 'bad length in SRT packet actual $1 claimed $2 interface $3' Parameters list: $1: sl25-actual-length $2: sl25-claimed-length $3: sl25-interface A bad length field or truncated packet was detected in a SRT bridge packet.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification26 1.3.6.1.4.1.2007.1.4.83.2.0.26
Notification of Event SL.26 Message: 'Packet received is shorter than Serial line header, actual $1 interface $2' Parameters list: $1: sl26-actual-length $2: sl26-interface An Incoming Serial Line packet is shorter than a minimally required Serial Line header. Such packet can not be processed and hence freed.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification27 1.3.6.1.4.1.2007.1.4.83.2.0.27
Notification of Event SL.27 Message: 'No level converter, disabling interface $1' Parameters list: $1: sl27-interface There is no level converter on this port of the Quad Serial Line card. The self-test will fail, and future self-tests will be cancelled.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification28 1.3.6.1.4.1.2007.1.4.83.2.0.28
Notification of Event SL.28 Message: 'Unknown level converter type $1, disabling interface $2' Parameters list: $1: sl28-converter-type $2: sl28-interface There is a level converter of an unknown type on this port of the Quad Serial Line card. The self-test will fail, and future self-tests will be cancelled.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification29 1.3.6.1.4.1.2007.1.4.83.2.0.29
Notification of Event SL.29 Message: 'Configured frame size of $1 bytes too small, increasing to $2 bytes, interface $3' Parameters list: $1: sl29-configured-size $2: sl29-minimum-size $3: sl29-interface The user-configured frame size for this interface is smaller than the minimum that is required for the particular serial line device. The size is increased to the minimum allowable one.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification30 1.3.6.1.4.1.2007.1.4.83.2.0.30
Notification of Event SL.30 Message: 'Maintenance buffer busy, interface $1' Parameters list: $1: sl30-interface The maintenance routine is attempting to send a maintenance frame for Proteon Serial data-link, but the buffer for sending this has not been freed since the previous maintenance. If this happens 3 times in a row, maintenance will fail at the other end of the serial line.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification31 1.3.6.1.4.1.2007.1.4.83.2.0.31
Notification of Event SL.31 Message: 'No packet for reading counters, interface $1' Parameters list: $1: sl31-interface A buffer could not be allocated when needed to read the statistics counters from the Dual Serial interface. The counters should be successfully updated at the next maintenance, 4 seconds later.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification32 1.3.6.1.4.1.2007.1.4.83.2.0.32
Notification of Event SL.32 Message: 'Packet buffer allocation number $1 failed, interface $2' Parameters list: $1: sl32-buffer-number $2: sl32-interface The allocation of a packet buffer for a DNX 300 serial line failed. This may be due to a shortage of either buffer memory or heap memory. (See the output of ELS messages GW.061, GW.063, and GW.064). The interface will still try and come up, but with a reduced number of receive packet buffers.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification33 1.3.6.1.4.1.2007.1.4.83.2.0.33
Notification of Event SL.33 Message: 'Packet buffer number $1 crossed 64 Kbyte page boundary, dropped, ifc $2' Parameters list: $1: sl33-buffer-number $2: sl33-interface A packet buffer was allocated for the DNX 300 serial line, but that buffer crossed a 64 Kbyte memory boundary in the buffer memory. Since all of the receive buffers for a DNX 300 serial line must be in the same 64 Kbyte buffer memory packet, that buffer will be ignored, and no further buffers will be allocated for the device. The interface will still try and come up, but with a reduced number of receive packet buffers.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification34 1.3.6.1.4.1.2007.1.4.83.2.0.34
Notification of Event SL.34 Message: 'No cable installed or installed cable broken or non-compatible, interface $1' Parameters list: $1: sl34-interface The system does not detect an adapter cable in the network interface port. Self-test will fail.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification35 1.3.6.1.4.1.2007.1.4.83.2.0.35
Notification of Event SL.35 Message: 'Protocol $1 ($2) can not be bridged over Proteon Serial Line using the pseudo-ethernet bridging method. Interface $3' Parameters list: $1: sl35-protocol-name $2: sl35-protocol-number $3: sl35-interface A protocol that cannot be bridged by Proteon Serial Line's PSEUDO- ETHERNET bridging method has been configured over an interface using PSL PSEUDO-ETH.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

slNotification36 1.3.6.1.4.1.2007.1.4.83.2.0.36
Notification of Event SL.36 Message: 'warning: test on ifc $1' Parameters list: $1: sl36-interface The interface is on mode loopback or echo and the timeout as expired.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE