TELDAT-TRAP-LLC-MIB

File: TELDAT-TRAP-LLC-MIB.mib (66124 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC TELDAT-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE OBJECT-IDENTITY
NOTIFICATION-TYPE Integer32 IpAddress
DisplayString telEventTraps

Defined Values

llcTrapsMIB 1.3.6.1.4.1.2007.1.4.103
This Module Information Base file is defined for managing received SNMP notifications generated by the LLC event subsystem.
MODULE-IDENTITY    

llcEventsGroup 1.3.6.1.4.1.2007.1.4.103.1
OBJECT IDENTIFIER    

llcNotifications 1.3.6.1.4.1.2007.1.4.103.2
OBJECT IDENTIFIER    

llcNotificationsPrefix 1.3.6.1.4.1.2007.1.4.103.2.0
OBJECT IDENTIFIER    

llcEventObjects1 1.3.6.1.4.1.2007.1.4.103.1.1
Event LLC.1 LLC is sending a frame. Possible frame types are: SABME-C0 or SABME-C1 (Set Asynchronous Balanced Mode Extended), DM-R0 or DM-R1 (Disconnected Mode), DISC-C0 or DISC-C1 (Disconnect), RR-C0 or RR-C1 or RR-R0 or RR-R1 (Receiver Ready), RNR-C0 or RNR-C1 or RNR-R0 or RNR-R1 (Receiver Not Ready), REJ-C0 or REJ-C1 or REJ-R0 or REJ-R1 (Reject), UA-R0 or UA-R1 (Unnumbered Acknowledgement), FRMR-R0 or FRMR-R1 (Frame Reject), and I-C0 or I-C1 or I-R0 or I-R1 (Information Frame). The abbrevation suffixes are C0 (command, poll bit off), C1 (command, poll bit on), R0 (response, final bit off) and R1 (response, final bit on).
Status: current Access: read-write
OBJECT-IDENTITY    

llc1-frame-type 1.3.6.1.4.1.2007.1.4.103.1.1.1
Parameter 'frame-type' in event LLC.1
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc1-src-mac 1.3.6.1.4.1.2007.1.4.103.1.1.2
Parameter 'src-mac' in event LLC.1
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc1-dst-mac 1.3.6.1.4.1.2007.1.4.103.1.1.3
Parameter 'dst-mac' in event LLC.1
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc1-rif 1.3.6.1.4.1.2007.1.4.103.1.1.4
Parameter 'rif' in event LLC.1
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc1-src-sap 1.3.6.1.4.1.2007.1.4.103.1.1.5
Parameter 'src-sap' in event LLC.1
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc1-dst-sap 1.3.6.1.4.1.2007.1.4.103.1.1.6
Parameter 'dst-sap' in event LLC.1
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc1-interface 1.3.6.1.4.1.2007.1.4.103.1.1.7
Parameter 'interface' in event LLC.1
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llcEventObjects2 1.3.6.1.4.1.2007.1.4.103.1.2
Event LLC.2 An event occurred on an llc2 connection. The LLC2 FSM (Finite State Machine) has been called to process the event. The LLC2 connection is uniquely identified by the combination destination MAC address, source MAC address, destination sap and source sap on a particular interface. The possible events are: SET-ABME (user request to connect to remote), SET-ADM (user request to disconnect from remote), SEND-BTU (user request to send data), FLOW-REQ-ON (user request to turn off local busy condition), FLOW-REQ-OFF (user request to turn on local busy condition), T1-EXP (T1 timer expiration), T2-EXP (T2 timer expiration), Ti-EXP (Ti timer epiration), OS-I-C0 or OS-I-C1 or OS-I-R0 or OS-I-R1 (Ns on I-frame is out of sequence), I-C0 or I-C1 or I-R0 or I-R1 (valid I-frame received), RR-C0 or RR-C1 or RR-R0 or RR-R1 (RR frame received), RNR-C0 or RNR-C1 or RNR-R0 or RNR-R1 (RNR frame received), REJ-C0 or REJ-C1 or REJ-R0 or REJ-R1 (REJ frame received), UA-R0 or UA-R1 (UA frame received), DISC-C0 or DISC-C1 (DISC frame received), DM-R0 or DM-R1 (DM frame received), FRMR-R0 or FRMR-R1 (FRMR frame received), BAD-FRAME-0 or BAD-FRAME-1 (received frame will generate FRMR), SABME-C0 or SABME-C1 (SABME frame received), and SEND-I-POLL (Sending I frame with Poll bit on). The abbrevation suffixes are C0 (command, poll bit off), C1 (command, poll bit on), R0 (response, final bit off) and R1 (response, final bit on).
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

llc2-llc-event 1.3.6.1.4.1.2007.1.4.103.1.2.1
Parameter 'llc-event' in event LLC.2
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc2-llc-state 1.3.6.1.4.1.2007.1.4.103.1.2.2
Parameter 'llc-state' in event LLC.2
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc2-llc2-connection 1.3.6.1.4.1.2007.1.4.103.1.2.3
Parameter 'llc2-connection' in event LLC.2
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc2-llc2-sap 1.3.6.1.4.1.2007.1.4.103.1.2.4
Parameter 'llc2-sap' in event LLC.2
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc2-interface 1.3.6.1.4.1.2007.1.4.103.1.2.5
Parameter 'interface' in event LLC.2
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llcEventObjects3 1.3.6.1.4.1.2007.1.4.103.1.3
Event LLC.3 There is LLC2 state change. The possible states are: DISCONNECTED (initial state), LINK-OPENING (link establishment in progress), DISCONNECTING (DISC sent, awaiting DM), FRMR-SENT (frmr sent), LINK-OPENED (normal state), LOCAL-BUSY (local is busy), REJECTION (remote sent an out of sequence frame), CHECKPOINTING (poll sent, awaiting response sending of data supended), CKPT-LB (combination state), CKPT-REJ (combination state), RESETTING (awaiting user response to reset), REMOTE-BUSY (remote is busy), LB-RB (combination state), REJ-LB (combination state), REJ-RB (combination state), CKPT-REJ-LB (combination state), CKPT-CLR (clearing from CKPT-LB state), CKPT-REJ-CLR (clearing from CKPT-REJ-LB state), REJ-LB-RB (combination state), FRMR-RECEIVED (received frmr). The abbreviations above are: CKPT=CHECKPOINTING, CLR=CLEARING, LB=LOCAL BUSY, RB=REMOTE BUSY, and REJ=REJECTION.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

llc3-llc-old-state 1.3.6.1.4.1.2007.1.4.103.1.3.1
Parameter 'llc-old-state' in event LLC.3
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc3-llc-new-state 1.3.6.1.4.1.2007.1.4.103.1.3.2
Parameter 'llc-new-state' in event LLC.3
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc3-llc2-connection 1.3.6.1.4.1.2007.1.4.103.1.3.3
Parameter 'llc2-connection' in event LLC.3
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc3-llc2-sap 1.3.6.1.4.1.2007.1.4.103.1.3.4
Parameter 'llc2-sap' in event LLC.3
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc3-interface 1.3.6.1.4.1.2007.1.4.103.1.3.5
Parameter 'interface' in event LLC.3
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llcEventObjects4 1.3.6.1.4.1.2007.1.4.103.1.4
Event LLC.4 LLC2 event upcall is occuring. Some of the arguments on the upcall are shown. User Cookie is meaningful to the router software running over the LLC subsystem. Event reason sometimes further specifies the event. The possible upcall events are: CONN-IND (cookie=session, reason=none), CONN-IND-PASS (cookie=sap, reason=none), CONN-CONFIRM (cookie=session, reason=none), DISC-IND (cookie=session, possible reasons: local term (disconnecting), remote term, conn refused, local term (disconnected)), RESET-IND (cookie=session, possible reasons: local reset, remote reset, frmr rcvd, frmr sent), RESET-CONF (cookie=session, reason=none), FLOW-IND (cookie=session, possible reasons: flow off, flow on), and DISC-CONFIRM (cookie=session, reason=none).
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

llc4-user-event 1.3.6.1.4.1.2007.1.4.103.1.4.1
Parameter 'user-event' in event LLC.4
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc4-user-value 1.3.6.1.4.1.2007.1.4.103.1.4.2
Parameter 'user-value' in event LLC.4
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc4-event-reason 1.3.6.1.4.1.2007.1.4.103.1.4.3
Parameter 'event-reason' in event LLC.4
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc4-llc2-connection 1.3.6.1.4.1.2007.1.4.103.1.4.4
Parameter 'llc2-connection' in event LLC.4
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc4-llc2-sap 1.3.6.1.4.1.2007.1.4.103.1.4.5
Parameter 'llc2-sap' in event LLC.4
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc4-interface 1.3.6.1.4.1.2007.1.4.103.1.4.6
Parameter 'interface' in event LLC.4
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llcEventObjects5 1.3.6.1.4.1.2007.1.4.103.1.5
Event LLC.5 A sap-releated LLC user-primitive was called. The possible SAP primitives are: OPEN-SAP, CLOSE-SAP, CLOSE-SAP-FORCED, MODIFY-SAP, OPEN-STATION, and UNITDATA.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

llc5-user-primitive 1.3.6.1.4.1.2007.1.4.103.1.5.1
Parameter 'user-primitive' in event LLC.5
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc5-SAP-value 1.3.6.1.4.1.2007.1.4.103.1.5.2
Parameter 'SAP-value' in event LLC.5
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc5-interface 1.3.6.1.4.1.2007.1.4.103.1.5.3
Parameter 'interface' in event LLC.5
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llcEventObjects6 1.3.6.1.4.1.2007.1.4.103.1.6
Event LLC.6 A llc2 connection non-data user-primitive was called. The possible primitives are: CLOSE-STATION, CLOSE-STATION-FORCED, CONNECT-REQUEST, CONNECT-RESPONSE, DISCONNECT-REQUEST, RESET-REQUEST, RESET-RESPONSE, FLOW-REQ.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

llc6-user-primitive 1.3.6.1.4.1.2007.1.4.103.1.6.1
Parameter 'user-primitive' in event LLC.6
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc6-llc2-connection 1.3.6.1.4.1.2007.1.4.103.1.6.2
Parameter 'llc2-connection' in event LLC.6
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc6-llc2-sap 1.3.6.1.4.1.2007.1.4.103.1.6.3
Parameter 'llc2-sap' in event LLC.6
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc6-interface 1.3.6.1.4.1.2007.1.4.103.1.6.4
Parameter 'interface' in event LLC.6
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llcEventObjects7 1.3.6.1.4.1.2007.1.4.103.1.7
Event LLC.7 A DATA-REQUEST data primitive was called. DATA-REQUEST passes the data in buffer memory.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

llc7-llc2-connection 1.3.6.1.4.1.2007.1.4.103.1.7.1
Parameter 'llc2-connection' in event LLC.7
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc7-llc2-sap 1.3.6.1.4.1.2007.1.4.103.1.7.2
Parameter 'llc2-sap' in event LLC.7
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc7-interface 1.3.6.1.4.1.2007.1.4.103.1.7.3
Parameter 'interface' in event LLC.7
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llcEventObjects8 1.3.6.1.4.1.2007.1.4.103.1.8
Event LLC.8 A DATA-LOCAL data primitive was called. DATA-LOCAL passes the data in data memory.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

llc8-llc2-connection 1.3.6.1.4.1.2007.1.4.103.1.8.1
Parameter 'llc2-connection' in event LLC.8
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc8-llc2-sap 1.3.6.1.4.1.2007.1.4.103.1.8.2
Parameter 'llc2-sap' in event LLC.8
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc8-interface 1.3.6.1.4.1.2007.1.4.103.1.8.3
Parameter 'interface' in event LLC.8
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llcEventObjects9 1.3.6.1.4.1.2007.1.4.103.1.9
Event LLC.9 A UNITDATA llc1 data primitive was called.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

llc9-SAP-value 1.3.6.1.4.1.2007.1.4.103.1.9.1
Parameter 'SAP-value' in event LLC.9
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc9-interface 1.3.6.1.4.1.2007.1.4.103.1.9.2
Parameter 'interface' in event LLC.9
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llcEventObjects10 1.3.6.1.4.1.2007.1.4.103.1.10
Event LLC.10 The oubound queue has grown grossly large. The llc2 connection is being automatically terminated.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

llc10-llc2-connection 1.3.6.1.4.1.2007.1.4.103.1.10.1
Parameter 'llc2-connection' in event LLC.10
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc10-llc2-sap 1.3.6.1.4.1.2007.1.4.103.1.10.2
Parameter 'llc2-sap' in event LLC.10
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc10-interface 1.3.6.1.4.1.2007.1.4.103.1.10.3
Parameter 'interface' in event LLC.10
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llcEventObjects11 1.3.6.1.4.1.2007.1.4.103.1.11
Event LLC.11 No buffer available to duplicate I-frame.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

llc11-llc2-connection 1.3.6.1.4.1.2007.1.4.103.1.11.1
Parameter 'llc2-connection' in event LLC.11
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc11-llc2-sap 1.3.6.1.4.1.2007.1.4.103.1.11.2
Parameter 'llc2-sap' in event LLC.11
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc11-interface 1.3.6.1.4.1.2007.1.4.103.1.11.3
Parameter 'interface' in event LLC.11
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llcEventObjects12 1.3.6.1.4.1.2007.1.4.103.1.12
Event LLC.12 No memory to duplicate I-frame.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

llc12-llc2-connection 1.3.6.1.4.1.2007.1.4.103.1.12.1
Parameter 'llc2-connection' in event LLC.12
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc12-llc2-sap 1.3.6.1.4.1.2007.1.4.103.1.12.2
Parameter 'llc2-sap' in event LLC.12
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc12-interface 1.3.6.1.4.1.2007.1.4.103.1.12.3
Parameter 'interface' in event LLC.12
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llcEventObjects13 1.3.6.1.4.1.2007.1.4.103.1.13
Event LLC.13 A buffer could not be obtained to to build an LLC Supervisory or Unnumbered frame. No loss of data integrity has occurred yet, but unless buffers for this purpose become available within a few seconds, the other end of the LLC2 connection will most likely terminate this LLC connection as part of the normal LLC2 protocol.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

llc13-llc2-connection 1.3.6.1.4.1.2007.1.4.103.1.13.1
Parameter 'llc2-connection' in event LLC.13
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc13-llc2-sap 1.3.6.1.4.1.2007.1.4.103.1.13.2
Parameter 'llc2-sap' in event LLC.13
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc13-interface 1.3.6.1.4.1.2007.1.4.103.1.13.3
Parameter 'interface' in event LLC.13
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llcEventObjects14 1.3.6.1.4.1.2007.1.4.103.1.14
Event LLC.14 The frame type the LLC is trying to build is invalid.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

llc14-llc2-connection 1.3.6.1.4.1.2007.1.4.103.1.14.1
Parameter 'llc2-connection' in event LLC.14
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc14-llc2-sap 1.3.6.1.4.1.2007.1.4.103.1.14.2
Parameter 'llc2-sap' in event LLC.14
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc14-interface 1.3.6.1.4.1.2007.1.4.103.1.14.3
Parameter 'interface' in event LLC.14
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llcEventObjects15 1.3.6.1.4.1.2007.1.4.103.1.15
Event LLC.15 The LLC2 Finite State Machine (FSM) was called with an event that was out of range.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

llc15-event-code-number 1.3.6.1.4.1.2007.1.4.103.1.15.1
Parameter 'event-code-number' in event LLC.15
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llcEventObjects16 1.3.6.1.4.1.2007.1.4.103.1.16
Event LLC.16 An OPEN SAP operation was tried on a network type that LLC does not support. Network types Token-Ring, Ethernet, and FDDI are supported.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

llc16-network-type 1.3.6.1.4.1.2007.1.4.103.1.16.1
Parameter 'network-type' in event LLC.16
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc16-interface 1.3.6.1.4.1.2007.1.4.103.1.16.2
Parameter 'interface' in event LLC.16
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llcEventObjects17 1.3.6.1.4.1.2007.1.4.103.1.17
Event LLC.17 A OPEN SAP operation was tried on a sap that has already been opened.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

llc17-SAP-value 1.3.6.1.4.1.2007.1.4.103.1.17.1
Parameter 'SAP-value' in event LLC.17
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc17-interface 1.3.6.1.4.1.2007.1.4.103.1.17.2
Parameter 'interface' in event LLC.17
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llcEventObjects18 1.3.6.1.4.1.2007.1.4.103.1.18
Event LLC.18 Unable to allocate memory for SAP control block.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

llc18-interface 1.3.6.1.4.1.2007.1.4.103.1.18.1
Parameter 'interface' in event LLC.18
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llcEventObjects19 1.3.6.1.4.1.2007.1.4.103.1.19
Event LLC.19 Unable to allocate memory for station control block.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

llc19-interface 1.3.6.1.4.1.2007.1.4.103.1.19.1
Parameter 'interface' in event LLC.19
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llcEventObjects20 1.3.6.1.4.1.2007.1.4.103.1.20
Event LLC.20 UI frame refused by the local application within the router.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

llc20-llc2-connection 1.3.6.1.4.1.2007.1.4.103.1.20.1
Parameter 'llc2-connection' in event LLC.20
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc20-llc2-sap 1.3.6.1.4.1.2007.1.4.103.1.20.2
Parameter 'llc2-sap' in event LLC.20
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc20-interface 1.3.6.1.4.1.2007.1.4.103.1.20.3
Parameter 'interface' in event LLC.20
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llcEventObjects21 1.3.6.1.4.1.2007.1.4.103.1.21
Event LLC.21 TEST frame refused by the local application within the router. The frame is passed on to the bridge code, etc.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

llc21-llc2-connection 1.3.6.1.4.1.2007.1.4.103.1.21.1
Parameter 'llc2-connection' in event LLC.21
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc21-llc2-sap 1.3.6.1.4.1.2007.1.4.103.1.21.2
Parameter 'llc2-sap' in event LLC.21
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc21-interface 1.3.6.1.4.1.2007.1.4.103.1.21.3
Parameter 'interface' in event LLC.21
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llcEventObjects22 1.3.6.1.4.1.2007.1.4.103.1.22
Event LLC.22 XID frame refused by the local application within the router. The frame is passed on to the bridge code, etc.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

llc22-llc2-connection 1.3.6.1.4.1.2007.1.4.103.1.22.1
Parameter 'llc2-connection' in event LLC.22
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc22-llc2-sap 1.3.6.1.4.1.2007.1.4.103.1.22.2
Parameter 'llc2-sap' in event LLC.22
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc22-interface 1.3.6.1.4.1.2007.1.4.103.1.22.3
Parameter 'interface' in event LLC.22
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llcEventObjects23 1.3.6.1.4.1.2007.1.4.103.1.23
Event LLC.23 LLC makes an upcall providing the LLC with a unitdata frame. The possible unitdata frames are: TEST-C0 or TEST-C1 or TEST-R0 or TEST-R1 (TEST frame), XID-C0 or XID-C1 or XID-R0 or XID-R1 (Exchange Identification frame), UI-C0 or UI-R0 (Unnumbered Information). The abbrevation suffixes are C0 (command, poll bit off), C1 (command, poll bit on), R0 (response, final bit off) and R1 (response, final bit on).
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

llc23-frame-type 1.3.6.1.4.1.2007.1.4.103.1.23.1
Parameter 'frame-type' in event LLC.23
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc23-src-mac 1.3.6.1.4.1.2007.1.4.103.1.23.2
Parameter 'src-mac' in event LLC.23
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc23-dst-mac 1.3.6.1.4.1.2007.1.4.103.1.23.3
Parameter 'dst-mac' in event LLC.23
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc23-rif 1.3.6.1.4.1.2007.1.4.103.1.23.4
Parameter 'rif' in event LLC.23
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc23-src-sap 1.3.6.1.4.1.2007.1.4.103.1.23.5
Parameter 'src-sap' in event LLC.23
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc23-dst-sap 1.3.6.1.4.1.2007.1.4.103.1.23.6
Parameter 'dst-sap' in event LLC.23
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc23-interface 1.3.6.1.4.1.2007.1.4.103.1.23.7
Parameter 'interface' in event LLC.23
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llcEventObjects24 1.3.6.1.4.1.2007.1.4.103.1.24
Event LLC.24 The sending of an LLC2 related outbound frame failed. The reason-code is the internal error code for the failure.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

llc24-reason-code 1.3.6.1.4.1.2007.1.4.103.1.24.1
Parameter 'reason-code' in event LLC.24
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc24-llc2-connection 1.3.6.1.4.1.2007.1.4.103.1.24.2
Parameter 'llc2-connection' in event LLC.24
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc24-llc2-sap 1.3.6.1.4.1.2007.1.4.103.1.24.3
Parameter 'llc2-sap' in event LLC.24
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc24-interface-name 1.3.6.1.4.1.2007.1.4.103.1.24.4
Parameter 'interface-name' in event LLC.24
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llcEventObjects25 1.3.6.1.4.1.2007.1.4.103.1.25
Event LLC.25 The sending of the user's UNITDATA or an LLC-generated XID or TEST response outbound frame failed. The possible frame test are: TEST-C0 or TEST-C1 or TEST-R0 or TEST-R1 (TEST frame), XID-C0 or XID-C1 or XID-R0 or XID-R1 (Exchange Identification frame), UI-C0 or UI-R0 (Unnumbered Information frame) and unexpected (not one of the above types). The abbrevation suffixes are C0 (command, poll bit off), C1 (command, poll bit on), R0 (response, final bit off), and R1 (response, final bit on).
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

llc25-frame-type 1.3.6.1.4.1.2007.1.4.103.1.25.1
Parameter 'frame-type' in event LLC.25
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc25-reason-code 1.3.6.1.4.1.2007.1.4.103.1.25.2
Parameter 'reason-code' in event LLC.25
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc25-llc2-connection 1.3.6.1.4.1.2007.1.4.103.1.25.3
Parameter 'llc2-connection' in event LLC.25
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc25-llc2-sap 1.3.6.1.4.1.2007.1.4.103.1.25.4
Parameter 'llc2-sap' in event LLC.25
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc25-interface 1.3.6.1.4.1.2007.1.4.103.1.25.5
Parameter 'interface' in event LLC.25
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llcEventObjects26 1.3.6.1.4.1.2007.1.4.103.1.26
Event LLC.26 Unable to allocate memory for an LLC-CONF-BLOCK at initialization time. LLC configuration defaults are used.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

llc26-interface 1.3.6.1.4.1.2007.1.4.103.1.26.1
Parameter 'interface' in event LLC.26
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llcEventObjects27 1.3.6.1.4.1.2007.1.4.103.1.27
Event LLC.27 LLC Configuration record read for this network. This only occurs at initialization time. The values in the LLC configuration record are used as default value on the interface.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

llc27-interface 1.3.6.1.4.1.2007.1.4.103.1.27.1
Parameter 'interface' in event LLC.27
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llcEventObjects28 1.3.6.1.4.1.2007.1.4.103.1.28
Event LLC.28 access-priority, on an interface that is not a token ring must be zero because it is not used.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

llc28-access-priority 1.3.6.1.4.1.2007.1.4.103.1.28.1
Parameter 'access-priority' in event LLC.28
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc28-interface 1.3.6.1.4.1.2007.1.4.103.1.28.2
Parameter 'interface' in event LLC.28
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llcEventObjects29 1.3.6.1.4.1.2007.1.4.103.1.29
Event LLC.29 The access priority is greater than 7. A default of 0 is used.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

llc29-access-priority 1.3.6.1.4.1.2007.1.4.103.1.29.1
Parameter 'access-priority' in event LLC.29
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc29-interface 1.3.6.1.4.1.2007.1.4.103.1.29.2
Parameter 'interface' in event LLC.29
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llcEventObjects30 1.3.6.1.4.1.2007.1.4.103.1.30
Event LLC.30 An LLC config record exists for an interface that does not have a LAN hardware type.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

llc30-hardware-type 1.3.6.1.4.1.2007.1.4.103.1.30.1
Parameter 'hardware-type' in event LLC.30
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc30-interface 1.3.6.1.4.1.2007.1.4.103.1.30.2
Parameter 'interface' in event LLC.30
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llcEventObjects31 1.3.6.1.4.1.2007.1.4.103.1.31
Event LLC.31 An LLC config record exists for an interface that does not exist.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

llc31-interface-number 1.3.6.1.4.1.2007.1.4.103.1.31.1
Parameter 'interface-number' in event LLC.31
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llcEventObjects32 1.3.6.1.4.1.2007.1.4.103.1.32
Event LLC.32 LLC user is sending a frame, or LLC itself is sending a TEST or XID response frame. The possible frame types are: TEST-C0 or TEST-C1 or TEST-R0 or TEST-R1 (TEST frame), XID-C0 or XID-C1 or XID-R0 or XID-R1 (Exchange Identification frame), UI-C0 or UI-R0 (Unnumbered Information frame). The abbrevation suffixes are C0 (command, poll bit off), C1 (command, poll bit on), R0 (response, final bit off) and R1 (response, final bit on).
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

llc32-frame-type 1.3.6.1.4.1.2007.1.4.103.1.32.1
Parameter 'frame-type' in event LLC.32
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc32-src-mac 1.3.6.1.4.1.2007.1.4.103.1.32.2
Parameter 'src-mac' in event LLC.32
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc32-dst-mac 1.3.6.1.4.1.2007.1.4.103.1.32.3
Parameter 'dst-mac' in event LLC.32
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc32-rif 1.3.6.1.4.1.2007.1.4.103.1.32.4
Parameter 'rif' in event LLC.32
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc32-src-sap 1.3.6.1.4.1.2007.1.4.103.1.32.5
Parameter 'src-sap' in event LLC.32
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc32-dst-sap 1.3.6.1.4.1.2007.1.4.103.1.32.6
Parameter 'dst-sap' in event LLC.32
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc32-interface 1.3.6.1.4.1.2007.1.4.103.1.32.7
Parameter 'interface' in event LLC.32
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llcEventObjects33 1.3.6.1.4.1.2007.1.4.103.1.33
Event LLC.33 LLC subsystem itself is responding to a TEST or XID frame. The possible frame types are: TEST-C0 or TEST-C1 (TEST frame), and XID-C0 or XID-C1 (Exchange Identification frame). The abbrevation suffixes are: C0=(command, poll bit off) and C1=(command, poll bit on).
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

llc33-frame-type 1.3.6.1.4.1.2007.1.4.103.1.33.1
Parameter 'frame-type' in event LLC.33
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc33-src-mac 1.3.6.1.4.1.2007.1.4.103.1.33.2
Parameter 'src-mac' in event LLC.33
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc33-dst-mac 1.3.6.1.4.1.2007.1.4.103.1.33.3
Parameter 'dst-mac' in event LLC.33
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc33-rif 1.3.6.1.4.1.2007.1.4.103.1.33.4
Parameter 'rif' in event LLC.33
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llc33-src-sap 1.3.6.1.4.1.2007.1.4.103.1.33.5
Parameter 'src-sap' in event LLC.33
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc33-dst-sap 1.3.6.1.4.1.2007.1.4.103.1.33.6
Parameter 'dst-sap' in event LLC.33
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

llc33-interface 1.3.6.1.4.1.2007.1.4.103.1.33.7
Parameter 'interface' in event LLC.33
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

llcNotification1 1.3.6.1.4.1.2007.1.4.103.2.0.1
Notification of Event LLC.1 Message: 'Sent $1, $2->$3, $4 saps $5->$6, interface $7' Parameters list: $1: llc1-frame-type $2: llc1-src-mac $3: llc1-dst-mac $4: llc1-rif $5: llc1-src-sap $6: llc1-dst-sap $7: llc1-interface LLC is sending a frame. Possible frame types are: SABME-C0 or SABME-C1 (Set Asynchronous Balanced Mode Extended), DM-R0 or DM-R1 (Disconnected Mode), DISC-C0 or DISC-C1 (Disconnect), RR-C0 or RR-C1 or RR-R0 or RR-R1 (Receiver Ready), RNR-C0 or RNR-C1 or RNR-R0 or RNR-R1 (Receiver Not Ready), REJ-C0 or REJ-C1 or REJ-R0 or REJ-R1 (Reject), UA-R0 or UA-R1 (Unnumbered Acknowledgement), FRMR-R0 or FRMR-R1 (Frame Reject), and I-C0 or I-C1 or I-R0 or I-R1 (Information Frame). The abbrevation suffixes are C0 (command, poll bit off), C1 (command, poll bit on), R0 (response, final bit off) and R1 (response, final bit on).
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

llcNotification2 1.3.6.1.4.1.2007.1.4.103.2.0.2
Notification of Event LLC.2 Message: 'event=$1 in state=$2, $3->$4, saps $5->$6, interface $7' Parameters list: $1: llc2-llc-event $2: llc2-llc-state $3: llc2-llc2-connection $4: llc2-llc2-connection $5: llc2-llc2-sap $6: llc2-llc2-sap $7: llc2-interface An event occurred on an llc2 connection. The LLC2 FSM (Finite State Machine) has been called to process the event. The LLC2 connection is uniquely identified by the combination destination MAC address, source MAC address, destination sap and source sap on a particular interface. The possible events are: SET-ABME (user request to connect to remote), SET-ADM (user request to disconnect from remote), SEND-BTU (user request to send data), FLOW-REQ-ON (user request to turn off local busy condition), FLOW-REQ-OFF (user request to turn on local busy condition), T1-EXP (T1 timer expiration), T2-EXP (T2 timer expiration), Ti-EXP (Ti timer epiration), OS-I-C0 or OS-I-C1 or OS-I-R0 or OS-I-R1 (Ns on I-frame is out of sequence), I-C0 or I-C1 or I-R0 or I-R1 (valid I-frame received), RR-C0 or RR-C1 or RR-R0 or RR-R1 (RR frame received), RNR-C0 or RNR-C1 or RNR-R0 or RNR-R1 (RNR frame received), REJ-C0 or REJ-C1 or REJ-R0 or REJ-R1 (REJ frame received), UA-R0 or UA-R1 (UA frame received), DISC-C0 or DISC-C1 (DISC frame received), DM-R0 or DM-R1 (DM frame received), FRMR-R0 or FRMR-R1 (FRMR frame received), BAD-FRAME-0 or BAD-FRAME-1 (received frame will generate FRMR), SABME-C0 or SABME-C1 (SABME frame received), and SEND-I-POLL (Sending I frame with Poll bit on). The abbrevation suffixes are C0 (command, poll bit off), C1 (command, poll bit on), R0 (response, final bit off) and R1 (response, final bit on).
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

llcNotification3 1.3.6.1.4.1.2007.1.4.103.2.0.3
Notification of Event LLC.3 Message: '$1 to $2, $3->$4, saps $5->$6, interface $7' Parameters list: $1: llc3-llc-old-state $2: llc3-llc-new-state $3: llc3-llc2-connection $4: llc3-llc2-connection $5: llc3-llc2-sap $6: llc3-llc2-sap $7: llc3-interface There is LLC2 state change. The possible states are: DISCONNECTED (initial state), LINK-OPENING (link establishment in progress), DISCONNECTING (DISC sent, awaiting DM), FRMR-SENT (frmr sent), LINK-OPENED (normal state), LOCAL-BUSY (local is busy), REJECTION (remote sent an out of sequence frame), CHECKPOINTING (poll sent, awaiting response sending of data supended), CKPT-LB (combination state), CKPT-REJ (combination state), RESETTING (awaiting user response to reset), REMOTE-BUSY (remote is busy), LB-RB (combination state), REJ-LB (combination state), REJ-RB (combination state), CKPT-REJ-LB (combination state), CKPT-CLR (clearing from CKPT-LB state), CKPT-REJ-CLR (clearing from CKPT-REJ-LB state), REJ-LB-RB (combination state), FRMR-RECEIVED (received frmr). The abbreviations above are: CKPT=CHECKPOINTING, CLR=CLEARING, LB=LOCAL BUSY, RB=REMOTE BUSY, and REJ=REJECTION.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

llcNotification4 1.3.6.1.4.1.2007.1.4.103.2.0.4
Notification of Event LLC.4 Message: 'Upcall user event $1 args $2/$3 on $4->$5, saps $6->$7, interface $8' Parameters list: $1: llc4-user-event $2: llc4-user-value $3: llc4-event-reason $4: llc4-llc2-connection $5: llc4-llc2-connection $6: llc4-llc2-sap $7: llc4-llc2-sap $8: llc4-interface LLC2 event upcall is occuring. Some of the arguments on the upcall are shown. User Cookie is meaningful to the router software running over the LLC subsystem. Event reason sometimes further specifies the event. The possible upcall events are: CONN-IND (cookie=session, reason=none), CONN-IND-PASS (cookie=sap, reason=none), CONN-CONFIRM (cookie=session, reason=none), DISC-IND (cookie=session, possible reasons: local term (disconnecting), remote term, conn refused, local term (disconnected)), RESET-IND (cookie=session, possible reasons: local reset, remote reset, frmr rcvd, frmr sent), RESET-CONF (cookie=session, reason=none), FLOW-IND (cookie=session, possible reasons: flow off, flow on), and DISC-CONFIRM (cookie=session, reason=none).
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

llcNotification5 1.3.6.1.4.1.2007.1.4.103.2.0.5
Notification of Event LLC.5 Message: 'user primitive $1 sap $2 on interface $3' Parameters list: $1: llc5-user-primitive $2: llc5-SAP-value $3: llc5-interface A sap-releated LLC user-primitive was called. The possible SAP primitives are: OPEN-SAP, CLOSE-SAP, CLOSE-SAP-FORCED, MODIFY-SAP, OPEN-STATION, and UNITDATA.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

llcNotification6 1.3.6.1.4.1.2007.1.4.103.2.0.6
Notification of Event LLC.6 Message: 'primitive $1, $2->$3, saps $4->$5, interface $6' Parameters list: $1: llc6-user-primitive $2: llc6-llc2-connection $3: llc6-llc2-connection $4: llc6-llc2-sap $5: llc6-llc2-sap $6: llc6-interface A llc2 connection non-data user-primitive was called. The possible primitives are: CLOSE-STATION, CLOSE-STATION-FORCED, CONNECT-REQUEST, CONNECT-RESPONSE, DISCONNECT-REQUEST, RESET-REQUEST, RESET-RESPONSE, FLOW-REQ.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

llcNotification7 1.3.6.1.4.1.2007.1.4.103.2.0.7
Notification of Event LLC.7 Message: 'data primitive, $1->$2, saps $3->$4, interface $5' Parameters list: $1: llc7-llc2-connection $2: llc7-llc2-connection $3: llc7-llc2-sap $4: llc7-llc2-sap $5: llc7-interface A DATA-REQUEST data primitive was called. DATA-REQUEST passes the data in buffer memory.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

llcNotification8 1.3.6.1.4.1.2007.1.4.103.2.0.8
Notification of Event LLC.8 Message: 'data primitive, $1->$2, saps $3->$4, interface $5' Parameters list: $1: llc8-llc2-connection $2: llc8-llc2-connection $3: llc8-llc2-sap $4: llc8-llc2-sap $5: llc8-interface A DATA-LOCAL data primitive was called. DATA-LOCAL passes the data in data memory.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

llcNotification9 1.3.6.1.4.1.2007.1.4.103.2.0.9
Notification of Event LLC.9 Message: 'unitdata primitive, sap $1 interface $2' Parameters list: $1: llc9-SAP-value $2: llc9-interface A UNITDATA llc1 data primitive was called.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

llcNotification10 1.3.6.1.4.1.2007.1.4.103.2.0.10
Notification of Event LLC.10 Message: 'outbound queue too big, $1->$2, saps $3->$4, interface $5' Parameters list: $1: llc10-llc2-connection $2: llc10-llc2-connection $3: llc10-llc2-sap $4: llc10-llc2-sap $5: llc10-interface The oubound queue has grown grossly large. The llc2 connection is being automatically terminated.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

llcNotification11 1.3.6.1.4.1.2007.1.4.103.2.0.11
Notification of Event LLC.11 Message: 'No buffer available to duplicate I-frame, $1->$2, saps $3->$4, interface $5' Parameters list: $1: llc11-llc2-connection $2: llc11-llc2-connection $3: llc11-llc2-sap $4: llc11-llc2-sap $5: llc11-interface No buffer available to duplicate I-frame.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

llcNotification12 1.3.6.1.4.1.2007.1.4.103.2.0.12
Notification of Event LLC.12 Message: 'No memory available to duplicate I-frame, $1->$2, saps $3->$4, interface $5' Parameters list: $1: llc12-llc2-connection $2: llc12-llc2-connection $3: llc12-llc2-sap $4: llc12-llc2-sap $5: llc12-interface No memory to duplicate I-frame.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

llcNotification13 1.3.6.1.4.1.2007.1.4.103.2.0.13
Notification of Event LLC.13 Message: 'No buffer for LLC frame, $1->$2, saps $3->$4, interface $5' Parameters list: $1: llc13-llc2-connection $2: llc13-llc2-connection $3: llc13-llc2-sap $4: llc13-llc2-sap $5: llc13-interface A buffer could not be obtained to to build an LLC Supervisory or Unnumbered frame. No loss of data integrity has occurred yet, but unless buffers for this purpose become available within a few seconds, the other end of the LLC2 connection will most likely terminate this LLC connection as part of the normal LLC2 protocol.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

llcNotification14 1.3.6.1.4.1.2007.1.4.103.2.0.14
Notification of Event LLC.14 Message: 'frame type invalid, $1->$2, saps $3->$4, interface $5' Parameters list: $1: llc14-llc2-connection $2: llc14-llc2-connection $3: llc14-llc2-sap $4: llc14-llc2-sap $5: llc14-interface The frame type the LLC is trying to build is invalid.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

llcNotification15 1.3.6.1.4.1.2007.1.4.103.2.0.15
Notification of Event LLC.15 Message: 'Invalid LLC2 FSM event $1' Parameters list: $1: llc15-event-code-number The LLC2 Finite State Machine (FSM) was called with an event that was out of range.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

llcNotification16 1.3.6.1.4.1.2007.1.4.103.2.0.16
Notification of Event LLC.16 Message: 'invalid network type $1 on interface $2' Parameters list: $1: llc16-network-type $2: llc16-interface An OPEN SAP operation was tried on a network type that LLC does not support. Network types Token-Ring, Ethernet, and FDDI are supported.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

llcNotification17 1.3.6.1.4.1.2007.1.4.103.2.0.17
Notification of Event LLC.17 Message: 'duplicate sap $1 on interface $2' Parameters list: $1: llc17-SAP-value $2: llc17-interface A OPEN SAP operation was tried on a sap that has already been opened.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

llcNotification18 1.3.6.1.4.1.2007.1.4.103.2.0.18
Notification of Event LLC.18 Message: 'No memory for SAP control block on interface $1' Parameters list: $1: llc18-interface Unable to allocate memory for SAP control block.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

llcNotification19 1.3.6.1.4.1.2007.1.4.103.2.0.19
Notification of Event LLC.19 Message: 'No memory for station control block on interface $1' Parameters list: $1: llc19-interface Unable to allocate memory for station control block.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

llcNotification20 1.3.6.1.4.1.2007.1.4.103.2.0.20
Notification of Event LLC.20 Message: 'UI frame dropped, $1->$2, saps $3->$4, interface $5' Parameters list: $1: llc20-llc2-connection $2: llc20-llc2-connection $3: llc20-llc2-sap $4: llc20-llc2-sap $5: llc20-interface UI frame refused by the local application within the router.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

llcNotification21 1.3.6.1.4.1.2007.1.4.103.2.0.21
Notification of Event LLC.21 Message: 'TEST frame refused, $1->$2, saps $3->$4, interface $5' Parameters list: $1: llc21-llc2-connection $2: llc21-llc2-connection $3: llc21-llc2-sap $4: llc21-llc2-sap $5: llc21-interface TEST frame refused by the local application within the router. The frame is passed on to the bridge code, etc.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

llcNotification22 1.3.6.1.4.1.2007.1.4.103.2.0.22
Notification of Event LLC.22 Message: 'XID frame refused, $1->$2, saps $3->$4, interface $5' Parameters list: $1: llc22-llc2-connection $2: llc22-llc2-connection $3: llc22-llc2-sap $4: llc22-llc2-sap $5: llc22-interface XID frame refused by the local application within the router. The frame is passed on to the bridge code, etc.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

llcNotification23 1.3.6.1.4.1.2007.1.4.103.2.0.23
Notification of Event LLC.23 Message: 'Upcall frame $1, $2->$3, $4 saps $5->$6, interface $7' Parameters list: $1: llc23-frame-type $2: llc23-src-mac $3: llc23-dst-mac $4: llc23-rif $5: llc23-src-sap $6: llc23-dst-sap $7: llc23-interface LLC makes an upcall providing the LLC with a unitdata frame. The possible unitdata frames are: TEST-C0 or TEST-C1 or TEST-R0 or TEST-R1 (TEST frame), XID-C0 or XID-C1 or XID-R0 or XID-R1 (Exchange Identification frame), UI-C0 or UI-R0 (Unnumbered Information). The abbrevation suffixes are C0 (command, poll bit off), C1 (command, poll bit on), R0 (response, final bit off) and R1 (response, final bit on).
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

llcNotification24 1.3.6.1.4.1.2007.1.4.103.2.0.24
Notification of Event LLC.24 Message: 'llc2 outbound frame dropped, reason $1, $2->$3, saps $4->$5, interface $6' Parameters list: $1: llc24-reason-code $2: llc24-llc2-connection $3: llc24-llc2-connection $4: llc24-llc2-sap $5: llc24-llc2-sap $6: llc24-interface-name The sending of an LLC2 related outbound frame failed. The reason-code is the internal error code for the failure.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

llcNotification25 1.3.6.1.4.1.2007.1.4.103.2.0.25
Notification of Event LLC.25 Message: '$1 outbound frame dropped, reason $2, $3->$4, saps $5->$6, interface $7' Parameters list: $1: llc25-frame-type $2: llc25-reason-code $3: llc25-llc2-connection $4: llc25-llc2-connection $5: llc25-llc2-sap $6: llc25-llc2-sap $7: llc25-interface The sending of the user's UNITDATA or an LLC-generated XID or TEST response outbound frame failed. The possible frame test are: TEST-C0 or TEST-C1 or TEST-R0 or TEST-R1 (TEST frame), XID-C0 or XID-C1 or XID-R0 or XID-R1 (Exchange Identification frame), UI-C0 or UI-R0 (Unnumbered Information frame) and unexpected (not one of the above types). The abbrevation suffixes are C0 (command, poll bit off), C1 (command, poll bit on), R0 (response, final bit off), and R1 (response, final bit on).
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

llcNotification26 1.3.6.1.4.1.2007.1.4.103.2.0.26
Notification of Event LLC.26 Message: 'No memory for LLC CONF BLOCK on interface $1' Parameters list: $1: llc26-interface Unable to allocate memory for an LLC-CONF-BLOCK at initialization time. LLC configuration defaults are used.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

llcNotification27 1.3.6.1.4.1.2007.1.4.103.2.0.27
Notification of Event LLC.27 Message: 'Read LLC Configuration record for interface $1' Parameters list: $1: llc27-interface LLC Configuration record read for this network. This only occurs at initialization time. The values in the LLC configuration record are used as default value on the interface.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

llcNotification28 1.3.6.1.4.1.2007.1.4.103.2.0.28
Notification of Event LLC.28 Message: 'Inv access priority $1 for interface $2' Parameters list: $1: llc28-access-priority $2: llc28-interface access-priority, on an interface that is not a token ring must be zero because it is not used.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

llcNotification29 1.3.6.1.4.1.2007.1.4.103.2.0.29
Notification of Event LLC.29 Message: 'Inv acc $1 for interface $2' Parameters list: $1: llc29-access-priority $2: llc29-interface The access priority is greater than 7. A default of 0 is used.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

llcNotification30 1.3.6.1.4.1.2007.1.4.103.2.0.30
Notification of Event LLC.30 Message: 'Invalid hardware type $1 for interface $2' Parameters list: $1: llc30-hardware-type $2: llc30-interface An LLC config record exists for an interface that does not have a LAN hardware type.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

llcNotification31 1.3.6.1.4.1.2007.1.4.103.2.0.31
Notification of Event LLC.31 Message: 'Invalid interface $1 in config' Parameters list: $1: llc31-interface-number An LLC config record exists for an interface that does not exist.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

llcNotification32 1.3.6.1.4.1.2007.1.4.103.2.0.32
Notification of Event LLC.32 Message: 'Sent $1, $2->$3, $4 saps $5->$6, interface $7' Parameters list: $1: llc32-frame-type $2: llc32-src-mac $3: llc32-dst-mac $4: llc32-rif $5: llc32-src-sap $6: llc32-dst-sap $7: llc32-interface LLC user is sending a frame, or LLC itself is sending a TEST or XID response frame. The possible frame types are: TEST-C0 or TEST-C1 or TEST-R0 or TEST-R1 (TEST frame), XID-C0 or XID-C1 or XID-R0 or XID-R1 (Exchange Identification frame), UI-C0 or UI-R0 (Unnumbered Information frame). The abbrevation suffixes are C0 (command, poll bit off), C1 (command, poll bit on), R0 (response, final bit off) and R1 (response, final bit on).
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

llcNotification33 1.3.6.1.4.1.2007.1.4.103.2.0.33
Notification of Event LLC.33 Message: 'frm to LLC, frm $1, $2->$3, $4 saps $5->$6, interface $7' Parameters list: $1: llc33-frame-type $2: llc33-src-mac $3: llc33-dst-mac $4: llc33-rif $5: llc33-src-sap $6: llc33-dst-sap $7: llc33-interface LLC subsystem itself is responding to a TEST or XID frame. The possible frame types are: TEST-C0 or TEST-C1 (TEST frame), and XID-C0 or XID-C1 (Exchange Identification frame). The abbrevation suffixes are: C0=(command, poll bit off) and C1=(command, poll bit on).
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE