TELDAT-TRAP-FRBK-MIB

File: TELDAT-TRAP-FRBK-MIB.mib (10791 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC TELDAT-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE OBJECT-IDENTITY
NOTIFICATION-TYPE Integer32 IpAddress
DisplayString telEventTraps

Defined Values

frbkTrapsMIB 1.3.6.1.4.1.2007.1.4.114
This Module Information Base file is defined for managing received SNMP notifications generated by the FRBK event subsystem.
MODULE-IDENTITY    

frbkEventsGroup 1.3.6.1.4.1.2007.1.4.114.1
OBJECT IDENTIFIER    

frbkNotifications 1.3.6.1.4.1.2007.1.4.114.2
OBJECT IDENTIFIER    

frbkNotificationsPrefix 1.3.6.1.4.1.2007.1.4.114.2.0
OBJECT IDENTIFIER    

frbkEventObjects1 1.3.6.1.4.1.2007.1.4.114.1.1
Event FRBK.1 A PVC switched to backup state.
Status: current Access: read-write
OBJECT-IDENTITY    

frbk1-circuit 1.3.6.1.4.1.2007.1.4.114.1.1.1
Parameter 'circuit' in event FRBK.1
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

frbk1-ifc-name 1.3.6.1.4.1.2007.1.4.114.1.1.2
Parameter 'ifc-name' in event FRBK.1
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frbkEventObjects2 1.3.6.1.4.1.2007.1.4.114.1.2
Event FRBK.2 A PVC returns from backup state to active state.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

frbk2-circuit 1.3.6.1.4.1.2007.1.4.114.1.2.1
Parameter 'circuit' in event FRBK.2
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

frbk2-ifc-name 1.3.6.1.4.1.2007.1.4.114.1.2.2
Parameter 'ifc-name' in event FRBK.2
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frbkEventObjects3 1.3.6.1.4.1.2007.1.4.114.1.3
Event FRBK.3 All PVCs in backup state are forced to return to active state whenever it is possible.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

frbk3-ifc-name 1.3.6.1.4.1.2007.1.4.114.1.3.1
Parameter 'ifc-name' in event FRBK.3
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frbkEventObjects4 1.3.6.1.4.1.2007.1.4.114.1.4
Event FRBK.4 When backup timer expires all circuits can switch to normal operation (if it is possible).
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

frbk4-ifc-name 1.3.6.1.4.1.2007.1.4.114.1.4.1
Parameter 'ifc-name' in event FRBK.4
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frbkEventObjects5 1.3.6.1.4.1.2007.1.4.114.1.5
Event FRBK.5 All traffic which normally goes through Frame Relay interface must be routered through the associated backup interface over ISDN.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

frbk5-ifc-name 1.3.6.1.4.1.2007.1.4.114.1.5.1
Parameter 'ifc-name' in event FRBK.5
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frbk5-isdn-ifc-name 1.3.6.1.4.1.2007.1.4.114.1.5.2
Parameter 'isdn-ifc-name' in event FRBK.5
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frbkEventObjects6 1.3.6.1.4.1.2007.1.4.114.1.6
Event FRBK.6 Frame Relay interface (primary link) has recovered: it is active and operative again, so the secondary link automatically disconnects and traffic stops being transmitted through the ISDN backup interface.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

frbk6-ifc-name 1.3.6.1.4.1.2007.1.4.114.1.6.1
Parameter 'ifc-name' in event FRBK.6
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frbk6-isdn-ifc-name 1.3.6.1.4.1.2007.1.4.114.1.6.2
Parameter 'isdn-ifc-name' in event FRBK.6
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frbkEventObjects7 1.3.6.1.4.1.2007.1.4.114.1.7
Event FRBK.7 A PVC switched to backup state.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

frbk7-circuit 1.3.6.1.4.1.2007.1.4.114.1.7.1
Parameter 'circuit' in event FRBK.7
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

frbk7-ifc-name 1.3.6.1.4.1.2007.1.4.114.1.7.2
Parameter 'ifc-name' in event FRBK.7
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frbk7-isdn-ifc-name 1.3.6.1.4.1.2007.1.4.114.1.7.3
Parameter 'isdn-ifc-name' in event FRBK.7
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frbkEventObjects8 1.3.6.1.4.1.2007.1.4.114.1.8
Event FRBK.8 A PVC returns from backup state to active state.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

frbk8-circuit 1.3.6.1.4.1.2007.1.4.114.1.8.1
Parameter 'circuit' in event FRBK.8
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

frbk8-ifc-name 1.3.6.1.4.1.2007.1.4.114.1.8.2
Parameter 'ifc-name' in event FRBK.8
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frbk8-isdn-ifc-name 1.3.6.1.4.1.2007.1.4.114.1.8.3
Parameter 'isdn-ifc-name' in event FRBK.8
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frbkNotification1 1.3.6.1.4.1.2007.1.4.114.2.0.1
Notification of Event FRBK.1 Message: 'Backup-PVC, PVC=$1 PVCBackup=$2, on interface $3' Parameters list: $1: frbk1-circuit $2: frbk1-circuit $3: frbk1-ifc-name A PVC switched to backup state.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frbkNotification2 1.3.6.1.4.1.2007.1.4.114.2.0.2
Notification of Event FRBK.2 Message: 'Return Backup-PVC, PVC=$1 PVCBackup= $2, on interface $3' Parameters list: $1: frbk2-circuit $2: frbk2-circuit $3: frbk2-ifc-name A PVC returns from backup state to active state.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frbkNotification3 1.3.6.1.4.1.2007.1.4.114.2.0.3
Notification of Event FRBK.3 Message: 'Return command Backup PVC, on interface $1' Parameters list: $1: frbk3-ifc-name All PVCs in backup state are forced to return to active state whenever it is possible.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frbkNotification4 1.3.6.1.4.1.2007.1.4.114.2.0.4
Notification of Event FRBK.4 Message: 'Tiemout Backup PVC, on interface $1' Parameters list: $1: frbk4-ifc-name When backup timer expires all circuits can switch to normal operation (if it is possible).
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frbkNotification5 1.3.6.1.4.1.2007.1.4.114.2.0.5
Notification of Event FRBK.5 Message: 'ISDN Backup, FR interface $1, RDSI interface $2' Parameters list: $1: frbk5-ifc-name $2: frbk5-isdn-ifc-name All traffic which normally goes through Frame Relay interface must be routered through the associated backup interface over ISDN.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frbkNotification6 1.3.6.1.4.1.2007.1.4.114.2.0.6
Notification of Event FRBK.6 Message: 'Return ISDN Backup, FR interface $1, RDSI interface $2' Parameters list: $1: frbk6-ifc-name $2: frbk6-isdn-ifc-name Frame Relay interface (primary link) has recovered: it is active and operative again, so the secondary link automatically disconnects and traffic stops being transmitted through the ISDN backup interface.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frbkNotification7 1.3.6.1.4.1.2007.1.4.114.2.0.7
Notification of Event FRBK.7 Message: 'ISDN Backup, PVC=$1 PVCBackup-ISDN=$2, FR interface $3 RDSI interface $4' Parameters list: $1: frbk7-circuit $2: frbk7-circuit $3: frbk7-ifc-name $4: frbk7-isdn-ifc-name A PVC switched to backup state.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frbkNotification8 1.3.6.1.4.1.2007.1.4.114.2.0.8
Notification of Event FRBK.8 Message: 'Return ISDN-Backup, PVC=$1 PVCBackup-ISDN = $2, FR interface $3 RDSI interface $4' Parameters list: $1: frbk8-circuit $2: frbk8-circuit $3: frbk8-ifc-name $4: frbk8-isdn-ifc-name A PVC returns from backup state to active state.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE