TELDAT-TRAP-FR-MIB

File: TELDAT-TRAP-FR-MIB.mib (66142 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC TELDAT-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE OBJECT-IDENTITY
NOTIFICATION-TYPE Integer32 IpAddress
DisplayString telEventTraps

Defined Values

frTrapsMIB 1.3.6.1.4.1.2007.1.4.92
This Module Information Base file is defined for managing received SNMP notifications generated by the FR event subsystem.
MODULE-IDENTITY    

frEventsGroup 1.3.6.1.4.1.2007.1.4.92.1
OBJECT IDENTIFIER    

frNotifications 1.3.6.1.4.1.2007.1.4.92.2
OBJECT IDENTIFIER    

frNotificationsPrefix 1.3.6.1.4.1.2007.1.4.92.2.0
OBJECT IDENTIFIER    

frEventObjects1 1.3.6.1.4.1.2007.1.4.92.1.1
Event FR.1 A frame had been received on the FR interface.
Status: current Access: read-write
OBJECT-IDENTITY    

fr1-circuit 1.3.6.1.4.1.2007.1.4.92.1.1.1
Parameter 'circuit' in event FR.1
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr1-protocol 1.3.6.1.4.1.2007.1.4.92.1.1.2
Parameter 'protocol' in event FR.1
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

fr1-size 1.3.6.1.4.1.2007.1.4.92.1.1.3
Parameter 'size' in event FR.1
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr1-ifcname 1.3.6.1.4.1.2007.1.4.92.1.1.4
Parameter 'ifcname' in event FR.1
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

fr1-buffer 1.3.6.1.4.1.2007.1.4.92.1.1.5
Parameter 'buffer' in event FR.1
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects2 1.3.6.1.4.1.2007.1.4.92.1.2
Event FR.2 A frame had been transmitted on the FR interface.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr2-circuit 1.3.6.1.4.1.2007.1.4.92.1.2.1
Parameter 'circuit' in event FR.2
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr2-protocol 1.3.6.1.4.1.2007.1.4.92.1.2.2
Parameter 'protocol' in event FR.2
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

fr2-size 1.3.6.1.4.1.2007.1.4.92.1.2.3
Parameter 'size' in event FR.2
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr2-ifcname 1.3.6.1.4.1.2007.1.4.92.1.2.4
Parameter 'ifcname' in event FR.2
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

fr2-buffer 1.3.6.1.4.1.2007.1.4.92.1.2.5
Parameter 'buffer' in event FR.2
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects3 1.3.6.1.4.1.2007.1.4.92.1.3
Event FR.3 A protocol frame had been discarded due to the PVC congested condition.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr3-circuit 1.3.6.1.4.1.2007.1.4.92.1.3.1
Parameter 'circuit' in event FR.3
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr3-protocol 1.3.6.1.4.1.2007.1.4.92.1.3.2
Parameter 'protocol' in event FR.3
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

fr3-ifcname 1.3.6.1.4.1.2007.1.4.92.1.3.3
Parameter 'ifcname' in event FR.3
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects4 1.3.6.1.4.1.2007.1.4.92.1.4
Event FR.4 The circuit is now experiencing congestion in the outbound direction.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr4-circuit 1.3.6.1.4.1.2007.1.4.92.1.4.1
Parameter 'circuit' in event FR.4
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr4-ifcname 1.3.6.1.4.1.2007.1.4.92.1.4.2
Parameter 'ifcname' in event FR.4
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects5 1.3.6.1.4.1.2007.1.4.92.1.5
Event FR.5 The circuit is now not experiencing congestion in the outbound direction.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr5-circuit 1.3.6.1.4.1.2007.1.4.92.1.5.1
Parameter 'circuit' in event FR.5
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr5-ifcname 1.3.6.1.4.1.2007.1.4.92.1.5.2
Parameter 'ifcname' in event FR.5
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects6 1.3.6.1.4.1.2007.1.4.92.1.6
Event FR.6 The circuit enters the active state.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr6-circuit 1.3.6.1.4.1.2007.1.4.92.1.6.1
Parameter 'circuit' in event FR.6
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr6-ifcname 1.3.6.1.4.1.2007.1.4.92.1.6.2
Parameter 'ifcname' in event FR.6
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects7 1.3.6.1.4.1.2007.1.4.92.1.7
Event FR.7 The LMI signalled present and active a circuit which had not been statically configured.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr7-circuit 1.3.6.1.4.1.2007.1.4.92.1.7.1
Parameter 'circuit' in event FR.7
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr7-ifcname 1.3.6.1.4.1.2007.1.4.92.1.7.2
Parameter 'ifcname' in event FR.7
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects8 1.3.6.1.4.1.2007.1.4.92.1.8
Event FR.8 The circuit enters the inactive state.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr8-circuit 1.3.6.1.4.1.2007.1.4.92.1.8.1
Parameter 'circuit' in event FR.8
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr8-ifcname 1.3.6.1.4.1.2007.1.4.92.1.8.2
Parameter 'ifcname' in event FR.8
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects9 1.3.6.1.4.1.2007.1.4.92.1.9
Event FR.9 The circuit is no longer available on the network.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr9-circuit 1.3.6.1.4.1.2007.1.4.92.1.9.1
Parameter 'circuit' in event FR.9
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr9-ifcname 1.3.6.1.4.1.2007.1.4.92.1.9.2
Parameter 'ifcname' in event FR.9
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects10 1.3.6.1.4.1.2007.1.4.92.1.10
Event FR.10 The circuit is now available on the network.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr10-circuit 1.3.6.1.4.1.2007.1.4.92.1.10.1
Parameter 'circuit' in event FR.10
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr10-ifcname 1.3.6.1.4.1.2007.1.4.92.1.10.2
Parameter 'ifcname' in event FR.10
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects11 1.3.6.1.4.1.2007.1.4.92.1.11
Event FR.11 A LMI sequence number exchange has been requested.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr11-rcvseq 1.3.6.1.4.1.2007.1.4.92.1.11.1
Parameter 'rcvseq' in event FR.11
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr11-xmtseq 1.3.6.1.4.1.2007.1.4.92.1.11.2
Parameter 'xmtseq' in event FR.11
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr11-ifcname 1.3.6.1.4.1.2007.1.4.92.1.11.3
Parameter 'ifcname' in event FR.11
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects12 1.3.6.1.4.1.2007.1.4.92.1.12
Event FR.12 A LMI full Status Enquiry has been requested.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr12-ifcname 1.3.6.1.4.1.2007.1.4.92.1.12.1
Parameter 'ifcname' in event FR.12
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects13 1.3.6.1.4.1.2007.1.4.92.1.13
Event FR.13 A solicited LMI Status Enquiry response has been received.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr13-ifcname 1.3.6.1.4.1.2007.1.4.92.1.13.1
Parameter 'ifcname' in event FR.13
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects14 1.3.6.1.4.1.2007.1.4.92.1.14
Event FR.14 A LMI full Status Enquiry response has been received.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr14-ifcname 1.3.6.1.4.1.2007.1.4.92.1.14.1
Parameter 'ifcname' in event FR.14
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects15 1.3.6.1.4.1.2007.1.4.92.1.15
Event FR.15 A modem status change has occurred. The present state is described.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr15-dcd 1.3.6.1.4.1.2007.1.4.92.1.15.1
Parameter 'dcd' in event FR.15
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

fr15-cts 1.3.6.1.4.1.2007.1.4.92.1.15.2
Parameter 'cts' in event FR.15
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

fr15-ifcname 1.3.6.1.4.1.2007.1.4.92.1.15.3
Parameter 'ifcname' in event FR.15
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects16 1.3.6.1.4.1.2007.1.4.92.1.16
Event FR.16 A multicast frame had been transmitted on the FR interface.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr16-circuit 1.3.6.1.4.1.2007.1.4.92.1.16.1
Parameter 'circuit' in event FR.16
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr16-protocol 1.3.6.1.4.1.2007.1.4.92.1.16.2
Parameter 'protocol' in event FR.16
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

fr16-ifcname 1.3.6.1.4.1.2007.1.4.92.1.16.3
Parameter 'ifcname' in event FR.16
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects17 1.3.6.1.4.1.2007.1.4.92.1.17
Event FR.17 The circuit is remaining in the outbound congested state toward the network.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr17-circuit 1.3.6.1.4.1.2007.1.4.92.1.17.1
Parameter 'circuit' in event FR.17
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr17-ifcname 1.3.6.1.4.1.2007.1.4.92.1.17.2
Parameter 'ifcname' in event FR.17
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects18 1.3.6.1.4.1.2007.1.4.92.1.18
Event FR.18 A protocol frame had been discarded due to the PVC exceeding the CIR on the circuit.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr18-circuit 1.3.6.1.4.1.2007.1.4.92.1.18.1
Parameter 'circuit' in event FR.18
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr18-protocol 1.3.6.1.4.1.2007.1.4.92.1.18.2
Parameter 'protocol' in event FR.18
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

fr18-ifcname 1.3.6.1.4.1.2007.1.4.92.1.18.3
Parameter 'ifcname' in event FR.18
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects19 1.3.6.1.4.1.2007.1.4.92.1.19
Event FR.19 The LMI signalled present and active a circuit which had not been statically configured or allowed.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr19-circuit 1.3.6.1.4.1.2007.1.4.92.1.19.1
Parameter 'circuit' in event FR.19
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr19-ifcname 1.3.6.1.4.1.2007.1.4.92.1.19.2
Parameter 'ifcname' in event FR.19
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects20 1.3.6.1.4.1.2007.1.4.92.1.20
Event FR.20 The LMI signalled present and active a circuit which cannot join the interface, maximum circuits have been exceeded.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr20-circuit 1.3.6.1.4.1.2007.1.4.92.1.20.1
Parameter 'circuit' in event FR.20
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr20-ifcname 1.3.6.1.4.1.2007.1.4.92.1.20.2
Parameter 'ifcname' in event FR.20
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects21 1.3.6.1.4.1.2007.1.4.92.1.21
Event FR.21 The LMI signalled present and active a circuit which cannot join the interface, memory is unavailable.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr21-circuit 1.3.6.1.4.1.2007.1.4.92.1.21.1
Parameter 'circuit' in event FR.21
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr21-ifcname 1.3.6.1.4.1.2007.1.4.92.1.21.2
Parameter 'ifcname' in event FR.21
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects22 1.3.6.1.4.1.2007.1.4.92.1.22
Event FR.22 An unsupported management information element has been encountered.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr22-type 1.3.6.1.4.1.2007.1.4.92.1.22.1
Parameter 'type' in event FR.22
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr22-ifcname 1.3.6.1.4.1.2007.1.4.92.1.22.2
Parameter 'ifcname' in event FR.22
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects23 1.3.6.1.4.1.2007.1.4.92.1.23
Event FR.23 An unsupported management message has been encountered.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr23-type 1.3.6.1.4.1.2007.1.4.92.1.23.1
Parameter 'type' in event FR.23
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr23-ifcname 1.3.6.1.4.1.2007.1.4.92.1.23.2
Parameter 'ifcname' in event FR.23
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects24 1.3.6.1.4.1.2007.1.4.92.1.24
Event FR.24 The LMI signalled present and active a multicast circuit.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr24-circuit 1.3.6.1.4.1.2007.1.4.92.1.24.1
Parameter 'circuit' in event FR.24
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr24-group 1.3.6.1.4.1.2007.1.4.92.1.24.2
Parameter 'group' in event FR.24
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr24-ifcname 1.3.6.1.4.1.2007.1.4.92.1.24.3
Parameter 'ifcname' in event FR.24
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects25 1.3.6.1.4.1.2007.1.4.92.1.25
Event FR.25 The LMI signalled present and active a multicast circuit.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr25-circuit 1.3.6.1.4.1.2007.1.4.92.1.25.1
Parameter 'circuit' in event FR.25
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr25-group 1.3.6.1.4.1.2007.1.4.92.1.25.2
Parameter 'group' in event FR.25
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr25-ifcname 1.3.6.1.4.1.2007.1.4.92.1.25.3
Parameter 'ifcname' in event FR.25
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects26 1.3.6.1.4.1.2007.1.4.92.1.26
Event FR.26 An unsupported network layer protocol NLPID has been encountered.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr26-type 1.3.6.1.4.1.2007.1.4.92.1.26.1
Parameter 'type' in event FR.26
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr26-circuit 1.3.6.1.4.1.2007.1.4.92.1.26.2
Parameter 'circuit' in event FR.26
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr26-size 1.3.6.1.4.1.2007.1.4.92.1.26.3
Parameter 'size' in event FR.26
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr26-ifcname 1.3.6.1.4.1.2007.1.4.92.1.26.4
Parameter 'ifcname' in event FR.26
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects27 1.3.6.1.4.1.2007.1.4.92.1.27
Event FR.27 An unsupported Ethernet type has been encountered.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr27-type 1.3.6.1.4.1.2007.1.4.92.1.27.1
Parameter 'type' in event FR.27
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr27-circuit 1.3.6.1.4.1.2007.1.4.92.1.27.2
Parameter 'circuit' in event FR.27
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr27-size 1.3.6.1.4.1.2007.1.4.92.1.27.3
Parameter 'size' in event FR.27
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr27-ifcname 1.3.6.1.4.1.2007.1.4.92.1.27.4
Parameter 'ifcname' in event FR.27
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects28 1.3.6.1.4.1.2007.1.4.92.1.28
Event FR.28 The LMI signalled present and active a multicast circuit that is not supported on the interface.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr28-circuit 1.3.6.1.4.1.2007.1.4.92.1.28.1
Parameter 'circuit' in event FR.28
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr28-group 1.3.6.1.4.1.2007.1.4.92.1.28.2
Parameter 'group' in event FR.28
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr28-ifcname 1.3.6.1.4.1.2007.1.4.92.1.28.3
Parameter 'ifcname' in event FR.28
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects29 1.3.6.1.4.1.2007.1.4.92.1.29
Event FR.29 Data has been received on a circuit not configured or learned dynamically but not yet active on network.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr29-circuit 1.3.6.1.4.1.2007.1.4.92.1.29.1
Parameter 'circuit' in event FR.29
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr29-ifcname 1.3.6.1.4.1.2007.1.4.92.1.29.2
Parameter 'ifcname' in event FR.29
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects30 1.3.6.1.4.1.2007.1.4.92.1.30
Event FR.30 A LMI sequence number exchange has been received.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr30-rcvseq 1.3.6.1.4.1.2007.1.4.92.1.30.1
Parameter 'rcvseq' in event FR.30
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr30-xmtseq 1.3.6.1.4.1.2007.1.4.92.1.30.2
Parameter 'xmtseq' in event FR.30
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr30-ifcname 1.3.6.1.4.1.2007.1.4.92.1.30.3
Parameter 'ifcname' in event FR.30
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects31 1.3.6.1.4.1.2007.1.4.92.1.31
Event FR.31 An LMI unsolicited single status update message has been received.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr31-ifcname 1.3.6.1.4.1.2007.1.4.92.1.31.1
Parameter 'ifcname' in event FR.31
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects32 1.3.6.1.4.1.2007.1.4.92.1.32
Event FR.32 A frame containing less than the 2 octet minimum address length had been encountered.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr32-ifcname 1.3.6.1.4.1.2007.1.4.92.1.32.1
Parameter 'ifcname' in event FR.32
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects33 1.3.6.1.4.1.2007.1.4.92.1.33
Event FR.33 A frame containing greater than the 2 octet maximum address length supported had been encountered. Currently, only 2 octet addressing is supported.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr33-ifcname 1.3.6.1.4.1.2007.1.4.92.1.33.1
Parameter 'ifcname' in event FR.33
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects34 1.3.6.1.4.1.2007.1.4.92.1.34
Event FR.34 The LMI status message contained a reserved management channel address.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr34-circuit 1.3.6.1.4.1.2007.1.4.92.1.34.1
Parameter 'circuit' in event FR.34
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr34-ifcname 1.3.6.1.4.1.2007.1.4.92.1.34.2
Parameter 'ifcname' in event FR.34
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects35 1.3.6.1.4.1.2007.1.4.92.1.35
Event FR.35 An unsupported link layer control frame encountered.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr35-type 1.3.6.1.4.1.2007.1.4.92.1.35.1
Parameter 'type' in event FR.35
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr35-circuit 1.3.6.1.4.1.2007.1.4.92.1.35.2
Parameter 'circuit' in event FR.35
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr35-ifcname 1.3.6.1.4.1.2007.1.4.92.1.35.3
Parameter 'ifcname' in event FR.35
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects36 1.3.6.1.4.1.2007.1.4.92.1.36
Event FR.36 An unsupported network layer protocol descriptor has been encountered.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr36-type 1.3.6.1.4.1.2007.1.4.92.1.36.1
Parameter 'type' in event FR.36
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr36-ifcname 1.3.6.1.4.1.2007.1.4.92.1.36.2
Parameter 'ifcname' in event FR.36
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects37 1.3.6.1.4.1.2007.1.4.92.1.37
Event FR.37 An unsupported network layer call reference field has been encountered.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr37-ifcname 1.3.6.1.4.1.2007.1.4.92.1.37.1
Parameter 'ifcname' in event FR.37
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects38 1.3.6.1.4.1.2007.1.4.92.1.38
Event FR.38 The received ANSI management frame did not include required locking shift information element.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr38-ifcname 1.3.6.1.4.1.2007.1.4.92.1.38.1
Parameter 'ifcname' in event FR.38
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects39 1.3.6.1.4.1.2007.1.4.92.1.39
Event FR.39 The received management frame information element was incorrectly formated.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr39-ifcname 1.3.6.1.4.1.2007.1.4.92.1.39.1
Parameter 'ifcname' in event FR.39
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects40 1.3.6.1.4.1.2007.1.4.92.1.40
Event FR.40 An incorrect LMI receive sequence number has been received.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr40-rcvseq 1.3.6.1.4.1.2007.1.4.92.1.40.1
Parameter 'rcvseq' in event FR.40
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr40-xmtseq 1.3.6.1.4.1.2007.1.4.92.1.40.2
Parameter 'xmtseq' in event FR.40
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr40-ifcname 1.3.6.1.4.1.2007.1.4.92.1.40.3
Parameter 'ifcname' in event FR.40
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects41 1.3.6.1.4.1.2007.1.4.92.1.41
Event FR.41 The LMI failed to signal the mentioned circuit is last network status update message. Circuit assumed removed from network.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr41-circuit 1.3.6.1.4.1.2007.1.4.92.1.41.1
Parameter 'circuit' in event FR.41
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr41-ifcname 1.3.6.1.4.1.2007.1.4.92.1.41.2
Parameter 'ifcname' in event FR.41
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects42 1.3.6.1.4.1.2007.1.4.92.1.42
Event FR.42 The circuit is now experiencing congestion in the inbound direction.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr42-circuit 1.3.6.1.4.1.2007.1.4.92.1.42.1
Parameter 'circuit' in event FR.42
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr42-ifcname 1.3.6.1.4.1.2007.1.4.92.1.42.2
Parameter 'ifcname' in event FR.42
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects43 1.3.6.1.4.1.2007.1.4.92.1.43
Event FR.43 The address header on received management frame had BECN, FECN, DE or CR bits set.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr43-ifcname 1.3.6.1.4.1.2007.1.4.92.1.43.1
Parameter 'ifcname' in event FR.43
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects44 1.3.6.1.4.1.2007.1.4.92.1.44
Event FR.44 LMI Link Integrity Verification message was received from the network without the router polling for it.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr44-ifcname 1.3.6.1.4.1.2007.1.4.92.1.44.1
Parameter 'ifcname' in event FR.44
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects45 1.3.6.1.4.1.2007.1.4.92.1.45
Event FR.45 LMI Full Status message was received from the network without the router polling for it.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr45-ifcname 1.3.6.1.4.1.2007.1.4.92.1.45.1
Parameter 'ifcname' in event FR.45
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects46 1.3.6.1.4.1.2007.1.4.92.1.46
Event FR.46 A frame was received of a bridge type defined in RFC 1490. However, since bridging has not been enabled on this circuit, frame is being discarded.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr46-circuit 1.3.6.1.4.1.2007.1.4.92.1.46.1
Parameter 'circuit' in event FR.46
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr46-ifcname 1.3.6.1.4.1.2007.1.4.92.1.46.2
Parameter 'ifcname' in event FR.46
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects47 1.3.6.1.4.1.2007.1.4.92.1.47
Event FR.47 A bridge frame is being discarded as a bridge port is not in forwarding state.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr47-circuit 1.3.6.1.4.1.2007.1.4.92.1.47.1
Parameter 'circuit' in event FR.47
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr47-ifcname 1.3.6.1.4.1.2007.1.4.92.1.47.2
Parameter 'ifcname' in event FR.47
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects48 1.3.6.1.4.1.2007.1.4.92.1.48
Event FR.48 A bridged frame has been received and is being discarded due to mismatch in the frame type versus the bridge port behavior.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr48-source-mac 1.3.6.1.4.1.2007.1.4.92.1.48.1
Parameter 'source-mac' in event FR.48
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

fr48-dest-mac 1.3.6.1.4.1.2007.1.4.92.1.48.2
Parameter 'dest-mac' in event FR.48
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

fr48-circuit 1.3.6.1.4.1.2007.1.4.92.1.48.3
Parameter 'circuit' in event FR.48
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr48-ifcname 1.3.6.1.4.1.2007.1.4.92.1.48.4
Parameter 'ifcname' in event FR.48
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects49 1.3.6.1.4.1.2007.1.4.92.1.49
Event FR.49 An unsupported bridge frame type has been encountered.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr49-type 1.3.6.1.4.1.2007.1.4.92.1.49.1
Parameter 'type' in event FR.49
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr49-circuit 1.3.6.1.4.1.2007.1.4.92.1.49.2
Parameter 'circuit' in event FR.49
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr49-ifcname 1.3.6.1.4.1.2007.1.4.92.1.49.3
Parameter 'ifcname' in event FR.49
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects50 1.3.6.1.4.1.2007.1.4.92.1.50
Event FR.50 An unrecognized outgoing bridge frame type. Bridge has asked the Frame Relay interface to send out a frame whose type cannot be translated into encapsulation defined in RFC 1490.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr50-type 1.3.6.1.4.1.2007.1.4.92.1.50.1
Parameter 'type' in event FR.50
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr50-circuit 1.3.6.1.4.1.2007.1.4.92.1.50.2
Parameter 'circuit' in event FR.50
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr50-ifcname 1.3.6.1.4.1.2007.1.4.92.1.50.3
Parameter 'ifcname' in event FR.50
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects51 1.3.6.1.4.1.2007.1.4.92.1.51
Event FR.51 A protocol frame has been discarded because it could not be queued for transmission.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr51-circuit 1.3.6.1.4.1.2007.1.4.92.1.51.1
Parameter 'circuit' in event FR.51
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr51-protocol 1.3.6.1.4.1.2007.1.4.92.1.51.2
Parameter 'protocol' in event FR.51
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

fr51-ifcname 1.3.6.1.4.1.2007.1.4.92.1.51.3
Parameter 'ifcname' in event FR.51
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects52 1.3.6.1.4.1.2007.1.4.92.1.52
Event FR.52 An LMI send sequence number of 0 has been received.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr52-sndseq 1.3.6.1.4.1.2007.1.4.92.1.52.1
Parameter 'sndseq' in event FR.52
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr52-ifcname 1.3.6.1.4.1.2007.1.4.92.1.52.2
Parameter 'ifcname' in event FR.52
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frEventObjects53 1.3.6.1.4.1.2007.1.4.92.1.53
Event FR.53 A FRF.12 fragment is processed and a event is reported.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

fr53-message 1.3.6.1.4.1.2007.1.4.92.1.53.1
Parameter 'message' in event FR.53
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

fr53-header 1.3.6.1.4.1.2007.1.4.92.1.53.2
Parameter 'header' in event FR.53
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr53-circuit 1.3.6.1.4.1.2007.1.4.92.1.53.3
Parameter 'circuit' in event FR.53
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr53-size 1.3.6.1.4.1.2007.1.4.92.1.53.4
Parameter 'size' in event FR.53
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fr53-ifcname 1.3.6.1.4.1.2007.1.4.92.1.53.5
Parameter 'ifcname' in event FR.53
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

frNotification1 1.3.6.1.4.1.2007.1.4.92.2.0.1
Notification of Event FR.1 Message: 'Frame received, PVC = $1 protocol type = $2 size $3 bytes, on interface $4HexadecimalData: $5' Parameters list: $1: fr1-circuit $2: fr1-protocol $3: fr1-size $4: fr1-ifcname $5: fr1-buffer A frame had been received on the FR interface.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification2 1.3.6.1.4.1.2007.1.4.92.2.0.2
Notification of Event FR.2 Message: 'Frame transmitted PVC = $1 protocol type = $2 size $3 bytes, on interface $4HexadecimalData: $5' Parameters list: $1: fr2-circuit $2: fr2-protocol $3: fr2-size $4: fr2-ifcname $5: fr2-buffer A frame had been transmitted on the FR interface.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification3 1.3.6.1.4.1.2007.1.4.92.2.0.3
Notification of Event FR.3 Message: 'Transmit frame discarded PVC = $1 protocol type = $2, on interface $3' Parameters list: $1: fr3-circuit $2: fr3-protocol $3: fr3-ifcname A protocol frame had been discarded due to the PVC congested condition.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification4 1.3.6.1.4.1.2007.1.4.92.2.0.4
Notification of Event FR.4 Message: 'Circuit outbound congestion PVC = $1, on interface $2' Parameters list: $1: fr4-circuit $2: fr4-ifcname The circuit is now experiencing congestion in the outbound direction.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification5 1.3.6.1.4.1.2007.1.4.92.2.0.5
Notification of Event FR.5 Message: 'Circuit outbound uncongested PVC = $1, on interface $2' Parameters list: $1: fr5-circuit $2: fr5-ifcname The circuit is now not experiencing congestion in the outbound direction.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification6 1.3.6.1.4.1.2007.1.4.92.2.0.6
Notification of Event FR.6 Message: 'Circuit enters active state PVC = $1, on interface $2' Parameters list: $1: fr6-circuit $2: fr6-ifcname The circuit enters the active state.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification7 1.3.6.1.4.1.2007.1.4.92.2.0.7
Notification of Event FR.7 Message: 'An orphan circuit not statically configured has joined the network PVC = $1, on interface $2' Parameters list: $1: fr7-circuit $2: fr7-ifcname The LMI signalled present and active a circuit which had not been statically configured.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification8 1.3.6.1.4.1.2007.1.4.92.2.0.8
Notification of Event FR.8 Message: 'Circuit enters inactive state PVC = $1, on interface $2' Parameters list: $1: fr8-circuit $2: fr8-ifcname The circuit enters the inactive state.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification9 1.3.6.1.4.1.2007.1.4.92.2.0.9
Notification of Event FR.9 Message: 'Circuit is unavailable PVC = $1, on interface $2' Parameters list: $1: fr9-circuit $2: fr9-ifcname The circuit is no longer available on the network.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification10 1.3.6.1.4.1.2007.1.4.92.2.0.10
Notification of Event FR.10 Message: 'Circuit is available PVC = $1, on interface $2' Parameters list: $1: fr10-circuit $2: fr10-ifcname The circuit is now available on the network.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification11 1.3.6.1.4.1.2007.1.4.92.2.0.11
Notification of Event FR.11 Message: 'LMI sequence number exchange requested, last received sequence = $1, current transmit sequence = $2, on interface $3' Parameters list: $1: fr11-rcvseq $2: fr11-xmtseq $3: fr11-ifcname A LMI sequence number exchange has been requested.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification12 1.3.6.1.4.1.2007.1.4.92.2.0.12
Notification of Event FR.12 Message: 'LMI Status Enquiry requested on interface $1' Parameters list: $1: fr12-ifcname A LMI full Status Enquiry has been requested.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification13 1.3.6.1.4.1.2007.1.4.92.2.0.13
Notification of Event FR.13 Message: 'LMI solicited Status Enquiry response had been received on interface $1' Parameters list: $1: fr13-ifcname A solicited LMI Status Enquiry response has been received.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification14 1.3.6.1.4.1.2007.1.4.92.2.0.14
Notification of Event FR.14 Message: 'LMI Full Status Enquiry response had been received on interface $1' Parameters list: $1: fr14-ifcname A LMI full Status Enquiry response has been received.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification15 1.3.6.1.4.1.2007.1.4.92.2.0.15
Notification of Event FR.15 Message: 'Modem status changed DCD = $1 CTS = $2 on interface $3' Parameters list: $1: fr15-dcd $2: fr15-cts $3: fr15-ifcname A modem status change has occurred. The present state is described.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification16 1.3.6.1.4.1.2007.1.4.92.2.0.16
Notification of Event FR.16 Message: 'Multicast frame transmitted PVC = $1 protocol type = $2, on interface $3' Parameters list: $1: fr16-circuit $2: fr16-protocol $3: fr16-ifcname A multicast frame had been transmitted on the FR interface.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification17 1.3.6.1.4.1.2007.1.4.92.2.0.17
Notification of Event FR.17 Message: 'Circuit remains congested in the outbound direction PVC = $1, on interface $2' Parameters list: $1: fr17-circuit $2: fr17-ifcname The circuit is remaining in the outbound congested state toward the network.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification18 1.3.6.1.4.1.2007.1.4.92.2.0.18
Notification of Event FR.18 Message: 'CIR exceeded, transmit frame discarded PVC = $1 protocol type = $2, on interface $3' Parameters list: $1: fr18-circuit $2: fr18-protocol $3: fr18-ifcname A protocol frame had been discarded due to the PVC exceeding the CIR on the circuit.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification19 1.3.6.1.4.1.2007.1.4.92.2.0.19
Notification of Event FR.19 Message: 'A disallowed orphan circuit not statically configured has been ignored PVC = $1, on interface $2' Parameters list: $1: fr19-circuit $2: fr19-ifcname The LMI signalled present and active a circuit which had not been statically configured or allowed.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification20 1.3.6.1.4.1.2007.1.4.92.2.0.20
Notification of Event FR.20 Message: 'The total circuits allowed has been exceeded, an orphan circuit has been ignored PVC = $1, on interface $2' Parameters list: $1: fr20-circuit $2: fr20-ifcname The LMI signalled present and active a circuit which cannot join the interface, maximum circuits have been exceeded.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification21 1.3.6.1.4.1.2007.1.4.92.2.0.21
Notification of Event FR.21 Message: 'No available memory for orphan circuit, the circuit has been ignored PVC = $1, on interface $2' Parameters list: $1: fr21-circuit $2: fr21-ifcname The LMI signalled present and active a circuit which cannot join the interface, memory is unavailable.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification22 1.3.6.1.4.1.2007.1.4.92.2.0.22
Notification of Event FR.22 Message: 'Unsupported LMI information element, type = $1 on interface $2' Parameters list: $1: fr22-type $2: fr22-ifcname An unsupported management information element has been encountered.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification23 1.3.6.1.4.1.2007.1.4.92.2.0.23
Notification of Event FR.23 Message: 'Unsupported LMI message type, type encountered = $1, on interface $2' Parameters list: $1: fr23-type $2: fr23-ifcname An unsupported management message has been encountered.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification24 1.3.6.1.4.1.2007.1.4.92.2.0.24
Notification of Event FR.24 Message: 'A multicast circuit has joined the network PVC = $1, in multicast group = $2 on interface $3' Parameters list: $1: fr24-circuit $2: fr24-group $3: fr24-ifcname The LMI signalled present and active a multicast circuit.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification25 1.3.6.1.4.1.2007.1.4.92.2.0.25
Notification of Event FR.25 Message: 'An multicast circuit has left the network PVC = $1, from multicast group = $2 on interface $3' Parameters list: $1: fr25-circuit $2: fr25-group $3: fr25-ifcname The LMI signalled present and active a multicast circuit.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification26 1.3.6.1.4.1.2007.1.4.92.2.0.26
Notification of Event FR.26 Message: 'Unsupported Network Layer Protocol ID, type = $1 from PVC = $2 size $3 bytes on interface $4' Parameters list: $1: fr26-type $2: fr26-circuit $3: fr26-size $4: fr26-ifcname An unsupported network layer protocol NLPID has been encountered.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification27 1.3.6.1.4.1.2007.1.4.92.2.0.27
Notification of Event FR.27 Message: 'Unsupported ethernet type, type = $1 from PVC = $2 size $3 bytes on interface $4' Parameters list: $1: fr27-type $2: fr27-circuit $3: fr27-size $4: fr27-ifcname An unsupported Ethernet type has been encountered.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification28 1.3.6.1.4.1.2007.1.4.92.2.0.28
Notification of Event FR.28 Message: 'An unsupported multicast circuit has been ignored, PVC = $1, in multicast group = $2 on interface $3' Parameters list: $1: fr28-circuit $2: fr28-group $3: fr28-ifcname The LMI signalled present and active a multicast circuit that is not supported on the interface.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification29 1.3.6.1.4.1.2007.1.4.92.2.0.29
Notification of Event FR.29 Message: 'Data received on invalid or nonconfigured circuit, PVC = $1 on interface $2' Parameters list: $1: fr29-circuit $2: fr29-ifcname Data has been received on a circuit not configured or learned dynamically but not yet active on network.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification30 1.3.6.1.4.1.2007.1.4.92.2.0.30
Notification of Event FR.30 Message: 'LMI sequence number exchange received, last received sequence = $1 current transmit sequence = $2, on interface $3' Parameters list: $1: fr30-rcvseq $2: fr30-xmtseq $3: fr30-ifcname A LMI sequence number exchange has been received.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification31 1.3.6.1.4.1.2007.1.4.92.2.0.31
Notification of Event FR.31 Message: 'LMI unsolicited single Status Update had been received on interface $1' Parameters list: $1: fr31-ifcname An LMI unsolicited single status update message has been received.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification32 1.3.6.1.4.1.2007.1.4.92.2.0.32
Notification of Event FR.32 Message: 'Circuit address length less than the 2 octet minimum received on interface $1' Parameters list: $1: fr32-ifcname A frame containing less than the 2 octet minimum address length had been encountered.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification33 1.3.6.1.4.1.2007.1.4.92.2.0.33
Notification of Event FR.33 Message: 'Circuit address length greater than the 2 octet maximum received on interface $1' Parameters list: $1: fr33-ifcname A frame containing greater than the 2 octet maximum address length supported had been encountered. Currently, only 2 octet addressing is supported.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification34 1.3.6.1.4.1.2007.1.4.92.2.0.34
Notification of Event FR.34 Message: 'Circuit status update message contained a reserved management channel address, PVC = $1, on interface $2' Parameters list: $1: fr34-circuit $2: fr34-ifcname The LMI status message contained a reserved management channel address.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification35 1.3.6.1.4.1.2007.1.4.92.2.0.35
Notification of Event FR.35 Message: 'Unsupported Link Layer Control frame encountered, type = $1 from PVC = $2 on interface $3' Parameters list: $1: fr35-type $2: fr35-circuit $3: fr35-ifcname An unsupported link layer control frame encountered.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification36 1.3.6.1.4.1.2007.1.4.92.2.0.36
Notification of Event FR.36 Message: 'Unsupported layer management protocol descriptor encountered, type = $1 on interface $2' Parameters list: $1: fr36-type $2: fr36-ifcname An unsupported network layer protocol descriptor has been encountered.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification37 1.3.6.1.4.1.2007.1.4.92.2.0.37
Notification of Event FR.37 Message: 'Unsupported layer management call reference encountered on interface $1' Parameters list: $1: fr37-ifcname An unsupported network layer call reference field has been encountered.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification38 1.3.6.1.4.1.2007.1.4.92.2.0.38
Notification of Event FR.38 Message: 'No lock shift encountered in received ANSI LMI message on interface $1' Parameters list: $1: fr38-ifcname The received ANSI management frame did not include required locking shift information element.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification39 1.3.6.1.4.1.2007.1.4.92.2.0.39
Notification of Event FR.39 Message: 'Incorrect formated information element encountered on interface $1' Parameters list: $1: fr39-ifcname The received management frame information element was incorrectly formated.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification40 1.3.6.1.4.1.2007.1.4.92.2.0.40
Notification of Event FR.40 Message: 'LMI receive sequence number in error, receive sequence = $1 expected sequence = $2, on interface $3' Parameters list: $1: fr40-rcvseq $2: fr40-xmtseq $3: fr40-ifcname An incorrect LMI receive sequence number has been received.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification41 1.3.6.1.4.1.2007.1.4.92.2.0.41
Notification of Event FR.41 Message: 'An circuit has been removed from the network PVC = $1, on interface $2' Parameters list: $1: fr41-circuit $2: fr41-ifcname The LMI failed to signal the mentioned circuit is last network status update message. Circuit assumed removed from network.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification42 1.3.6.1.4.1.2007.1.4.92.2.0.42
Notification of Event FR.42 Message: 'Circuit inbound congestion PVC = $1, on interface $2' Parameters list: $1: fr42-circuit $2: fr42-ifcname The circuit is now experiencing congestion in the inbound direction.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification43 1.3.6.1.4.1.2007.1.4.92.2.0.43
Notification of Event FR.43 Message: 'Incorrect formatted address header for LMI packet encountered on interface $1' Parameters list: $1: fr43-ifcname The address header on received management frame had BECN, FECN, DE or CR bits set.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification44 1.3.6.1.4.1.2007.1.4.92.2.0.44
Notification of Event FR.44 Message: 'Unsolicited LMI Link Integrity Verification received on interface $1' Parameters list: $1: fr44-ifcname LMI Link Integrity Verification message was received from the network without the router polling for it.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification45 1.3.6.1.4.1.2007.1.4.92.2.0.45
Notification of Event FR.45 Message: 'Unsolicited LMI FULL STATUS response received on interface $1' Parameters list: $1: fr45-ifcname LMI Full Status message was received from the network without the router polling for it.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification46 1.3.6.1.4.1.2007.1.4.92.2.0.46
Notification of Event FR.46 Message: 'DROP: Bridging not enabled on PVC=$1, on interface $2' Parameters list: $1: fr46-circuit $2: fr46-ifcname A frame was received of a bridge type defined in RFC 1490. However, since bridging has not been enabled on this circuit, frame is being discarded.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification47 1.3.6.1.4.1.2007.1.4.92.2.0.47
Notification of Event FR.47 Message: 'DROP: Bridge port not forwarding on PVC=$1, on interface $2' Parameters list: $1: fr47-circuit $2: fr47-ifcname A bridge frame is being discarded as a bridge port is not in forwarding state.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification48 1.3.6.1.4.1.2007.1.4.92.2.0.48
Notification of Event FR.48 Message: 'DROP: $1->$2, Frame to bridge port behavior mismatch on PVC=$3, on interface $4' Parameters list: $1: fr48-source-mac $2: fr48-dest-mac $3: fr48-circuit $4: fr48-ifcname A bridged frame has been received and is being discarded due to mismatch in the frame type versus the bridge port behavior.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification49 1.3.6.1.4.1.2007.1.4.92.2.0.49
Notification of Event FR.49 Message: 'Unsupported bridge frame type = $1 from PVC = $2 on interface $3' Parameters list: $1: fr49-type $2: fr49-circuit $3: fr49-ifcname An unsupported bridge frame type has been encountered.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification50 1.3.6.1.4.1.2007.1.4.92.2.0.50
Notification of Event FR.50 Message: 'Unrecognized outgoing bridge frame type = $1 on PVC = $2 on interface $3' Parameters list: $1: fr50-type $2: fr50-circuit $3: fr50-ifcname An unrecognized outgoing bridge frame type. Bridge has asked the Frame Relay interface to send out a frame whose type cannot be translated into encapsulation defined in RFC 1490.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification51 1.3.6.1.4.1.2007.1.4.92.2.0.51
Notification of Event FR.51 Message: 'Transmit frame discarded PVC = $1 protocol type = $2, on interface $3' Parameters list: $1: fr51-circuit $2: fr51-protocol $3: fr51-ifcname A protocol frame has been discarded because it could not be queued for transmission.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification52 1.3.6.1.4.1.2007.1.4.92.2.0.52
Notification of Event FR.52 Message: 'LMI send sequence number in error, sequence = $1, on interface $2' Parameters list: $1: fr52-sndseq $2: fr52-ifcname An LMI send sequence number of 0 has been received.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

frNotification53 1.3.6.1.4.1.2007.1.4.92.2.0.53
Notification of Event FR.53 Message: 'FRF.12 $1 header $2 on PVC = $3 size $4 bytes, on interface $5' Parameters list: $1: fr53-message $2: fr53-header $3: fr53-circuit $4: fr53-size $5: fr53-ifcname A FRF.12 fragment is processed and a event is reported.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE