TELDAT-TRAP-BR-MIB

File: TELDAT-TRAP-BR-MIB.mib (91727 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC TELDAT-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE OBJECT-IDENTITY
NOTIFICATION-TYPE Integer32 IpAddress
DisplayString telEventTraps

Defined Values

brTrapsMIB 1.3.6.1.4.1.2007.1.4.74
This Module Information Base file is defined for managing received SNMP notifications generated by the BR event subsystem.
MODULE-IDENTITY    

brEventsGroup 1.3.6.1.4.1.2007.1.4.74.1
OBJECT IDENTIFIER    

brNotifications 1.3.6.1.4.1.2007.1.4.74.2
OBJECT IDENTIFIER    

brNotificationsPrefix 1.3.6.1.4.1.2007.1.4.74.2.0
OBJECT IDENTIFIER    

brEventObjects1 1.3.6.1.4.1.2007.1.4.74.1.1
Event BR.1 A MAC frame has been received by the hardware, but is being dropped because the port it was received on is in the 'blocking' or 'listening' state. Frames are only processed when the port is in the 'learning' or 'forwarding' state.
Status: current Access: read-write
OBJECT-IDENTITY    

br1-source-mac 1.3.6.1.4.1.2007.1.4.74.1.1.1
Parameter 'source-mac' in event BR.1
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br1-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.1.2
Parameter 'dest-mac' in event BR.1
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br1-interface 1.3.6.1.4.1.2007.1.4.74.1.1.3
Parameter 'interface' in event BR.1
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects2 1.3.6.1.4.1.2007.1.4.74.1.2
Event BR.2 A MAC frame has been received whose destination address is known to be on the same side of the bridge as the packet came from. It is dropped by the filtering logic since it does not need to be bridged. Note that this event is not counted by ELS for performance reasons. A counter is kept in ASRT, it is the 'Dropped, dest addr filtering' entry in the ASRT>LIST SOURCE-ROUTE COUNTERS and ASRT>LIST TRANSPARENT COUNTERS commands.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br2-source-mac 1.3.6.1.4.1.2007.1.4.74.1.2.1
Parameter 'source-mac' in event BR.2
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br2-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.2.2
Parameter 'dest-mac' in event BR.2
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br2-interface 1.3.6.1.4.1.2007.1.4.74.1.2.3
Parameter 'interface' in event BR.2
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects3 1.3.6.1.4.1.2007.1.4.74.1.3
Event BR.3 A frame has been received over a WAN interface in the Ethernet bridge encapsulation, but the IPX protocol (in 802.3 encapsulation) is routed by this node.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br3-source-mac 1.3.6.1.4.1.2007.1.4.74.1.3.1
Parameter 'source-mac' in event BR.3
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br3-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.3.2
Parameter 'dest-mac' in event BR.3
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br3-interface 1.3.6.1.4.1.2007.1.4.74.1.3.3
Parameter 'interface' in event BR.3
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects4 1.3.6.1.4.1.2007.1.4.74.1.4
Event BR.4 A frame has been received for the IPX protocol (in 802.3 encapsulation), but the IPX protocol is being administratively filtered by the bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br4-source-mac 1.3.6.1.4.1.2007.1.4.74.1.4.1
Parameter 'source-mac' in event BR.4
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br4-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.4.2
Parameter 'dest-mac' in event BR.4
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br4-interface 1.3.6.1.4.1.2007.1.4.74.1.4.3
Parameter 'interface' in event BR.4
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects5 1.3.6.1.4.1.2007.1.4.74.1.5
Event BR.5 A frame has been received for the specified IEEE 802 Subnetwork Access Protocol (SNAP) Protocol Identifier (PID), but this PID is being administratively filtered by the bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br5-source-mac 1.3.6.1.4.1.2007.1.4.74.1.5.1
Parameter 'source-mac' in event BR.5
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br5-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.5.2
Parameter 'dest-mac' in event BR.5
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br5-protocol-identifier 1.3.6.1.4.1.2007.1.4.74.1.5.3
Parameter 'protocol-identifier' in event BR.5
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

br5-interface 1.3.6.1.4.1.2007.1.4.74.1.5.4
Parameter 'interface' in event BR.5
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects6 1.3.6.1.4.1.2007.1.4.74.1.6
Event BR.6 A frame has been received for the IEEE 802 Subnetwork Access Protocol (SNAP) Protocol Identifier (PID) which corresponds with an enabled protocol, but the destination MAC address is not registered in the bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br6-source-mac 1.3.6.1.4.1.2007.1.4.74.1.6.1
Parameter 'source-mac' in event BR.6
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br6-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.6.2
Parameter 'dest-mac' in event BR.6
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br6-protocol-identifier 1.3.6.1.4.1.2007.1.4.74.1.6.3
Parameter 'protocol-identifier' in event BR.6
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

br6-interface 1.3.6.1.4.1.2007.1.4.74.1.6.4
Parameter 'interface' in event BR.6
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects7 1.3.6.1.4.1.2007.1.4.74.1.7
Event BR.7 A multicast frame has been received for the IEEE 802 Subnetwork Access Protocol (SNAP) Protocol Identifier (PID) which corresponds with an endnode protocol. The frame will be both bridged and locally processed by the endnode protocol.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br7-source-mac 1.3.6.1.4.1.2007.1.4.74.1.7.1
Parameter 'source-mac' in event BR.7
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br7-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.7.2
Parameter 'dest-mac' in event BR.7
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br7-protocol-identifier 1.3.6.1.4.1.2007.1.4.74.1.7.3
Parameter 'protocol-identifier' in event BR.7
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

br7-interface 1.3.6.1.4.1.2007.1.4.74.1.7.4
Parameter 'interface' in event BR.7
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects8 1.3.6.1.4.1.2007.1.4.74.1.8
Event BR.8 An IEEE 802.2 frame has been received over a WAN interface in a bridge encapsulation, but its IEEE 802 Subnetwork Access Protocol (SNAP) Protocol Identifier (PID) is one that is being routed by this node. The frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br8-source-mac 1.3.6.1.4.1.2007.1.4.74.1.8.1
Parameter 'source-mac' in event BR.8
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br8-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.8.2
Parameter 'dest-mac' in event BR.8
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br8-protocol-identifier 1.3.6.1.4.1.2007.1.4.74.1.8.3
Parameter 'protocol-identifier' in event BR.8
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

br8-interface 1.3.6.1.4.1.2007.1.4.74.1.8.4
Parameter 'interface' in event BR.8
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects9 1.3.6.1.4.1.2007.1.4.74.1.9
Event BR.9 An IEEE 802.1D Bridge Protocol Data Unit (BPDU) was received at the wrong destination address. It is supposed to be addressed to a particular multicast address. The BPDU will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br9-source-mac 1.3.6.1.4.1.2007.1.4.74.1.9.1
Parameter 'source-mac' in event BR.9
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br9-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.9.2
Parameter 'dest-mac' in event BR.9
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br9-interface 1.3.6.1.4.1.2007.1.4.74.1.9.3
Parameter 'interface' in event BR.9
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects10 1.3.6.1.4.1.2007.1.4.74.1.10
Event BR.10 A frame has been received for the specified IEEE 802.2 Destination Service Access Point (DSAP), but this DSAP is being administratively filtered by the bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br10-source-mac 1.3.6.1.4.1.2007.1.4.74.1.10.1
Parameter 'source-mac' in event BR.10
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br10-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.10.2
Parameter 'dest-mac' in event BR.10
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br10-destination-service-access-point 1.3.6.1.4.1.2007.1.4.74.1.10.3
Parameter 'destination-service-access-point' in event BR.10
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

br10-interface 1.3.6.1.4.1.2007.1.4.74.1.10.4
Parameter 'interface' in event BR.10
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects11 1.3.6.1.4.1.2007.1.4.74.1.11
Event BR.11 A frame has been received for the IEEE 802.2 Destination Service Access Point (DSAP) which corresponds with an enabled protocol, but the destination MAC address is not registered in the bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br11-source-mac 1.3.6.1.4.1.2007.1.4.74.1.11.1
Parameter 'source-mac' in event BR.11
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br11-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.11.2
Parameter 'dest-mac' in event BR.11
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br11-destination-service-access-point 1.3.6.1.4.1.2007.1.4.74.1.11.3
Parameter 'destination-service-access-point' in event BR.11
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

br11-interface 1.3.6.1.4.1.2007.1.4.74.1.11.4
Parameter 'interface' in event BR.11
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects12 1.3.6.1.4.1.2007.1.4.74.1.12
Event BR.12 A multicast frame has been received for the IEEE 802.2 Destination Service Access Point (DSAP) which corresponds with an endnode protocol. The frame will be both bridged and locally processed by the endnode protocol.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br12-source-mac 1.3.6.1.4.1.2007.1.4.74.1.12.1
Parameter 'source-mac' in event BR.12
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br12-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.12.2
Parameter 'dest-mac' in event BR.12
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br12-destination-service-access-point 1.3.6.1.4.1.2007.1.4.74.1.12.3
Parameter 'destination-service-access-point' in event BR.12
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

br12-interface 1.3.6.1.4.1.2007.1.4.74.1.12.4
Parameter 'interface' in event BR.12
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects13 1.3.6.1.4.1.2007.1.4.74.1.13
Event BR.13 An IEEE 802.2 frame has been received over a WAN interface in a bridge encapsulation, but its IEEE 802.2 Destination Service Access Point (DSAP) is one that is being routed by this node. The frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br13-source-mac 1.3.6.1.4.1.2007.1.4.74.1.13.1
Parameter 'source-mac' in event BR.13
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br13-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.13.2
Parameter 'dest-mac' in event BR.13
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br13-destination-service-access-point 1.3.6.1.4.1.2007.1.4.74.1.13.3
Parameter 'destination-service-access-point' in event BR.13
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

br13-interface 1.3.6.1.4.1.2007.1.4.74.1.13.4
Parameter 'interface' in event BR.13
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects14 1.3.6.1.4.1.2007.1.4.74.1.14
Event BR.14 A frame has been received for the specified Ethernet type, but this type is being administratively filtered by the bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br14-source-mac 1.3.6.1.4.1.2007.1.4.74.1.14.1
Parameter 'source-mac' in event BR.14
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br14-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.14.2
Parameter 'dest-mac' in event BR.14
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br14-Ethernet-type 1.3.6.1.4.1.2007.1.4.74.1.14.3
Parameter 'Ethernet-type' in event BR.14
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

br14-interface 1.3.6.1.4.1.2007.1.4.74.1.14.4
Parameter 'interface' in event BR.14
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects15 1.3.6.1.4.1.2007.1.4.74.1.15
Event BR.15 A frame has been received for the Ethernet type which corresponds with an enabled protocol, but the destination MAC address is not registered in the bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br15-source-mac 1.3.6.1.4.1.2007.1.4.74.1.15.1
Parameter 'source-mac' in event BR.15
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br15-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.15.2
Parameter 'dest-mac' in event BR.15
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br15-Ethernet-type 1.3.6.1.4.1.2007.1.4.74.1.15.3
Parameter 'Ethernet-type' in event BR.15
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

br15-interface 1.3.6.1.4.1.2007.1.4.74.1.15.4
Parameter 'interface' in event BR.15
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects16 1.3.6.1.4.1.2007.1.4.74.1.16
Event BR.16 A multicast frame has been received for the Ethernet type which corresponds with an endnode protocol. The frame will be both bridged and locally processed by the endnode protocol.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br16-source-mac 1.3.6.1.4.1.2007.1.4.74.1.16.1
Parameter 'source-mac' in event BR.16
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br16-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.16.2
Parameter 'dest-mac' in event BR.16
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br16-Ethernet-type 1.3.6.1.4.1.2007.1.4.74.1.16.3
Parameter 'Ethernet-type' in event BR.16
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

br16-interface 1.3.6.1.4.1.2007.1.4.74.1.16.4
Parameter 'interface' in event BR.16
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects17 1.3.6.1.4.1.2007.1.4.74.1.17
Event BR.17 An Ethernet frame has been received over a WAN interface in the Ethernet bridge encapsulation, but its Ethernet type is one that is being routed by this node. The frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br17-source-mac 1.3.6.1.4.1.2007.1.4.74.1.17.1
Parameter 'source-mac' in event BR.17
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br17-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.17.2
Parameter 'dest-mac' in event BR.17
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br17-Ethernet-type 1.3.6.1.4.1.2007.1.4.74.1.17.3
Parameter 'Ethernet-type' in event BR.17
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

br17-interface 1.3.6.1.4.1.2007.1.4.74.1.17.4
Parameter 'interface' in event BR.17
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects18 1.3.6.1.4.1.2007.1.4.74.1.18
Event BR.18 A source-routed frame has been received for the specified IEEE 802.2 Destination Service Access Point (DSAP), but this DSAP is being administratively filtered by the bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br18-source-mac 1.3.6.1.4.1.2007.1.4.74.1.18.1
Parameter 'source-mac' in event BR.18
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br18-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.18.2
Parameter 'dest-mac' in event BR.18
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br18-destination-service-access-point 1.3.6.1.4.1.2007.1.4.74.1.18.3
Parameter 'destination-service-access-point' in event BR.18
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

br18-interface 1.3.6.1.4.1.2007.1.4.74.1.18.4
Parameter 'interface' in event BR.18
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects19 1.3.6.1.4.1.2007.1.4.74.1.19
Event BR.19 A source-routed frame has been received for the IEEE 802.2 Destination Service Access Point (DSAP) which corresponds with an enabled protocol, but the destination MAC address is not registered in the bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br19-source-mac 1.3.6.1.4.1.2007.1.4.74.1.19.1
Parameter 'source-mac' in event BR.19
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br19-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.19.2
Parameter 'dest-mac' in event BR.19
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br19-destination-service-access-point 1.3.6.1.4.1.2007.1.4.74.1.19.3
Parameter 'destination-service-access-point' in event BR.19
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

br19-interface 1.3.6.1.4.1.2007.1.4.74.1.19.4
Parameter 'interface' in event BR.19
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects20 1.3.6.1.4.1.2007.1.4.74.1.20
Event BR.20 A multicast source-routed frame has been received for the IEEE 802.2 Destination Service Access Point (DSAP) which corresponds with an endnode protocol. The frame will be both bridged and locally processed by the endnode protocol.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br20-source-mac 1.3.6.1.4.1.2007.1.4.74.1.20.1
Parameter 'source-mac' in event BR.20
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br20-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.20.2
Parameter 'dest-mac' in event BR.20
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br20-destination-service-access-point 1.3.6.1.4.1.2007.1.4.74.1.20.3
Parameter 'destination-service-access-point' in event BR.20
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

br20-interface 1.3.6.1.4.1.2007.1.4.74.1.20.4
Parameter 'interface' in event BR.20
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects21 1.3.6.1.4.1.2007.1.4.74.1.21
Event BR.21 A source-routed frame has been received for the specified IEEE 802 Subnetwork Access Protocol (SNAP) Protocol Identifier (PID), but this PID is being administratively filtered by the bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br21-source-mac 1.3.6.1.4.1.2007.1.4.74.1.21.1
Parameter 'source-mac' in event BR.21
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br21-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.21.2
Parameter 'dest-mac' in event BR.21
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br21-protocol-identifier 1.3.6.1.4.1.2007.1.4.74.1.21.3
Parameter 'protocol-identifier' in event BR.21
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

br21-interface 1.3.6.1.4.1.2007.1.4.74.1.21.4
Parameter 'interface' in event BR.21
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects22 1.3.6.1.4.1.2007.1.4.74.1.22
Event BR.22 A source-routed frame has been received for the IEEE 802 Subnetwork Access Protocol (SNAP) Protocol Identifier (PID) which corresponds with an enabled protocol, but the destination MAC address is not registered in the bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br22-source-mac 1.3.6.1.4.1.2007.1.4.74.1.22.1
Parameter 'source-mac' in event BR.22
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br22-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.22.2
Parameter 'dest-mac' in event BR.22
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br22-protocol-identifier 1.3.6.1.4.1.2007.1.4.74.1.22.3
Parameter 'protocol-identifier' in event BR.22
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

br22-interface 1.3.6.1.4.1.2007.1.4.74.1.22.4
Parameter 'interface' in event BR.22
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects23 1.3.6.1.4.1.2007.1.4.74.1.23
Event BR.23 SA source-routed multicast frame has been received for the IEEE 802 Subnetwork Access Protocol (SNAP) Protocol Identifier (PID) which corresponds with an endnode protocol. The frame will be both bridged and locally processed by the endnode protocol.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br23-source-mac 1.3.6.1.4.1.2007.1.4.74.1.23.1
Parameter 'source-mac' in event BR.23
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br23-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.23.2
Parameter 'dest-mac' in event BR.23
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br23-protocol-identifier 1.3.6.1.4.1.2007.1.4.74.1.23.3
Parameter 'protocol-identifier' in event BR.23
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

br23-interface 1.3.6.1.4.1.2007.1.4.74.1.23.4
Parameter 'interface' in event BR.23
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects24 1.3.6.1.4.1.2007.1.4.74.1.24
Event BR.24 A vlan frame has been received whose virtual lan id is not supported. Frame is dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br24-vlan-id 1.3.6.1.4.1.2007.1.4.74.1.24.1
Parameter 'vlan-id' in event BR.24
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

br24-interface 1.3.6.1.4.1.2007.1.4.74.1.24.2
Parameter 'interface' in event BR.24
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects26 1.3.6.1.4.1.2007.1.4.74.1.26
Event BR.26 A source-routed MAC frame has been received by the hardware, but is being dropped because the destination MAC address is being administratively filtered by the bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br26-source-mac 1.3.6.1.4.1.2007.1.4.74.1.26.1
Parameter 'source-mac' in event BR.26
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br26-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.26.2
Parameter 'dest-mac' in event BR.26
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br26-interface 1.3.6.1.4.1.2007.1.4.74.1.26.3
Parameter 'interface' in event BR.26
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects27 1.3.6.1.4.1.2007.1.4.74.1.27
Event BR.27 A source-routed MAC frame has been received by the hardware, but is being dropped because the source MAC address is being administratively filtered by the bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br27-source-mac 1.3.6.1.4.1.2007.1.4.74.1.27.1
Parameter 'source-mac' in event BR.27
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br27-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.27.2
Parameter 'dest-mac' in event BR.27
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br27-interface 1.3.6.1.4.1.2007.1.4.74.1.27.3
Parameter 'interface' in event BR.27
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects28 1.3.6.1.4.1.2007.1.4.74.1.28
Event BR.28 A multicast frame has been received for an endnode protocol that is both bridged and locally processed. There was no buffer to make two copies of the frame for both types of processing, so it will not be bridged, only locally processed.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br28-source-mac 1.3.6.1.4.1.2007.1.4.74.1.28.1
Parameter 'source-mac' in event BR.28
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br28-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.28.2
Parameter 'dest-mac' in event BR.28
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br28-interface 1.3.6.1.4.1.2007.1.4.74.1.28.3
Parameter 'interface' in event BR.28
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects29 1.3.6.1.4.1.2007.1.4.74.1.29
Event BR.29 A NETBIOS packet has matched the criteria specified in a NETBIOS Filter configuration record. The packet is dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br29-source-mac 1.3.6.1.4.1.2007.1.4.74.1.29.1
Parameter 'source-mac' in event BR.29
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br29-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.29.2
Parameter 'dest-mac' in event BR.29
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br29-port 1.3.6.1.4.1.2007.1.4.74.1.29.3
Parameter 'port' in event BR.29
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

br29-interface 1.3.6.1.4.1.2007.1.4.74.1.29.4
Parameter 'interface' in event BR.29
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects30 1.3.6.1.4.1.2007.1.4.74.1.30
Event BR.30 The MAC address of a BVI interface has been updated
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br30-interface 1.3.6.1.4.1.2007.1.4.74.1.30.1
Parameter 'interface' in event BR.30
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br30-new-mac 1.3.6.1.4.1.2007.1.4.74.1.30.2
Parameter 'new-mac' in event BR.30
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects31 1.3.6.1.4.1.2007.1.4.74.1.31
Event BR.31 A frame is going to be output to the bridge through a BVI interface.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br31-interface 1.3.6.1.4.1.2007.1.4.74.1.31.1
Parameter 'interface' in event BR.31
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br31-source-mac 1.3.6.1.4.1.2007.1.4.74.1.31.2
Parameter 'source-mac' in event BR.31
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br31-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.31.3
Parameter 'dest-mac' in event BR.31
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br31-protocol 1.3.6.1.4.1.2007.1.4.74.1.31.4
Parameter 'protocol' in event BR.31
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

brEventObjects32 1.3.6.1.4.1.2007.1.4.74.1.32
Event BR.32 A frame has been received in a BVI interface.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br32-interface 1.3.6.1.4.1.2007.1.4.74.1.32.1
Parameter 'interface' in event BR.32
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br32-source-mac 1.3.6.1.4.1.2007.1.4.74.1.32.2
Parameter 'source-mac' in event BR.32
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br32-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.32.3
Parameter 'dest-mac' in event BR.32
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br32-protocol 1.3.6.1.4.1.2007.1.4.74.1.32.4
Parameter 'protocol' in event BR.32
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

brEventObjects33 1.3.6.1.4.1.2007.1.4.74.1.33
Event BR.33 A frame is droped because BVI interface is down
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br33-interface 1.3.6.1.4.1.2007.1.4.74.1.33.1
Parameter 'interface' in event BR.33
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects34 1.3.6.1.4.1.2007.1.4.74.1.34
Event BR.34 A frame is dropped because destination IP has no registered MAC address.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br34-interface 1.3.6.1.4.1.2007.1.4.74.1.34.1
Parameter 'interface' in event BR.34
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br34-source-mac 1.3.6.1.4.1.2007.1.4.74.1.34.2
Parameter 'source-mac' in event BR.34
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br34-dest-IP-address 1.3.6.1.4.1.2007.1.4.74.1.34.3
Parameter 'dest-IP-address' in event BR.34
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  IpAddress  

brEventObjects35 1.3.6.1.4.1.2007.1.4.74.1.35
Event BR.35 A frame is droped because BVI interface has no protocol handler
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br35-interface 1.3.6.1.4.1.2007.1.4.74.1.35.1
Parameter 'interface' in event BR.35
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br35-protocol 1.3.6.1.4.1.2007.1.4.74.1.35.2
Parameter 'protocol' in event BR.35
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

brEventObjects36 1.3.6.1.4.1.2007.1.4.74.1.36
Event BR.36 A frame has been received for the specified IEEE 802 Subnetwork Access Protocol (SNAP) Protocol Identifier (PID), but this PID has no forwarder or endnode support. The frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br36-source-mac 1.3.6.1.4.1.2007.1.4.74.1.36.1
Parameter 'source-mac' in event BR.36
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br36-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.36.2
Parameter 'dest-mac' in event BR.36
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br36-protocol-identifier 1.3.6.1.4.1.2007.1.4.74.1.36.3
Parameter 'protocol-identifier' in event BR.36
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

br36-interface 1.3.6.1.4.1.2007.1.4.74.1.36.4
Parameter 'interface' in event BR.36
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects37 1.3.6.1.4.1.2007.1.4.74.1.37
Event BR.37 A frame has been received for the specified IEEE 802 Subnetwork Access Protocol (SNAP) Protocol Identifier (PID), but this PID has no enabled bridging nor routing. The frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br37-source-mac 1.3.6.1.4.1.2007.1.4.74.1.37.1
Parameter 'source-mac' in event BR.37
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br37-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.37.2
Parameter 'dest-mac' in event BR.37
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br37-protocol-identifier 1.3.6.1.4.1.2007.1.4.74.1.37.3
Parameter 'protocol-identifier' in event BR.37
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

br37-interface 1.3.6.1.4.1.2007.1.4.74.1.37.4
Parameter 'interface' in event BR.37
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects38 1.3.6.1.4.1.2007.1.4.74.1.38
Event BR.38 A frame has been received for the specified IEEE 802.2 Destination Service Access Point (DSAP), but this DSAP has no forwarder or endnode support. The frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br38-source-mac 1.3.6.1.4.1.2007.1.4.74.1.38.1
Parameter 'source-mac' in event BR.38
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br38-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.38.2
Parameter 'dest-mac' in event BR.38
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br38-destination-service-access-point 1.3.6.1.4.1.2007.1.4.74.1.38.3
Parameter 'destination-service-access-point' in event BR.38
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

br38-interface 1.3.6.1.4.1.2007.1.4.74.1.38.4
Parameter 'interface' in event BR.38
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects39 1.3.6.1.4.1.2007.1.4.74.1.39
Event BR.39 A frame has been received for the specified IEEE 802.2 Destination Service Access Point (DSAP), but this DSAP has no enabled bridging nor routing. The frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br39-source-mac 1.3.6.1.4.1.2007.1.4.74.1.39.1
Parameter 'source-mac' in event BR.39
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br39-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.39.2
Parameter 'dest-mac' in event BR.39
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br39-destination-service-access-point 1.3.6.1.4.1.2007.1.4.74.1.39.3
Parameter 'destination-service-access-point' in event BR.39
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

br39-interface 1.3.6.1.4.1.2007.1.4.74.1.39.4
Parameter 'interface' in event BR.39
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects40 1.3.6.1.4.1.2007.1.4.74.1.40
Event BR.40 A frame has been received for the specified Ethernet type, but this type has no forwarder or endnode support. The frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br40-source-mac 1.3.6.1.4.1.2007.1.4.74.1.40.1
Parameter 'source-mac' in event BR.40
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br40-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.40.2
Parameter 'dest-mac' in event BR.40
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br40-Ethernet-type 1.3.6.1.4.1.2007.1.4.74.1.40.3
Parameter 'Ethernet-type' in event BR.40
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

br40-interface 1.3.6.1.4.1.2007.1.4.74.1.40.4
Parameter 'interface' in event BR.40
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects41 1.3.6.1.4.1.2007.1.4.74.1.41
Event BR.41 A frame has been received for the specified Ethernet type, but this type has no enabled bridging nor routing. The frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br41-source-mac 1.3.6.1.4.1.2007.1.4.74.1.41.1
Parameter 'source-mac' in event BR.41
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br41-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.41.2
Parameter 'dest-mac' in event BR.41
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br41-Ethernet-type 1.3.6.1.4.1.2007.1.4.74.1.41.3
Parameter 'Ethernet-type' in event BR.41
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

br41-interface 1.3.6.1.4.1.2007.1.4.74.1.41.4
Parameter 'interface' in event BR.41
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects42 1.3.6.1.4.1.2007.1.4.74.1.42
Event BR.42 A source-routed frame has been received for the specified IEEE 802.2 Destination Service Access Point (DSAP), but this DSAP has no enabled bridging nor routing. The frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br42-source-mac 1.3.6.1.4.1.2007.1.4.74.1.42.1
Parameter 'source-mac' in event BR.42
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br42-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.42.2
Parameter 'dest-mac' in event BR.42
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br42-destination-service-access-point 1.3.6.1.4.1.2007.1.4.74.1.42.3
Parameter 'destination-service-access-point' in event BR.42
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

br42-interface 1.3.6.1.4.1.2007.1.4.74.1.42.4
Parameter 'interface' in event BR.42
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects43 1.3.6.1.4.1.2007.1.4.74.1.43
Event BR.43 A source-routed frame has been received for the specified IEEE 802 Subnetwork Access Protocol (SNAP) Protocol Identifier (PID), but this PID has no enabled bridging nor routing. The frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br43-source-mac 1.3.6.1.4.1.2007.1.4.74.1.43.1
Parameter 'source-mac' in event BR.43
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br43-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.43.2
Parameter 'dest-mac' in event BR.43
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br43-protocol-identifier 1.3.6.1.4.1.2007.1.4.74.1.43.3
Parameter 'protocol-identifier' in event BR.43
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

br43-interface 1.3.6.1.4.1.2007.1.4.74.1.43.4
Parameter 'interface' in event BR.43
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects44 1.3.6.1.4.1.2007.1.4.74.1.44
Event BR.44 A frame has been received with vlan identifier FFF. This frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br44-source-mac 1.3.6.1.4.1.2007.1.4.74.1.44.1
Parameter 'source-mac' in event BR.44
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br44-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.44.2
Parameter 'dest-mac' in event BR.44
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br44-interface 1.3.6.1.4.1.2007.1.4.74.1.44.3
Parameter 'interface' in event BR.44
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects45 1.3.6.1.4.1.2007.1.4.74.1.45
Event BR.45 A frame has been received with no vlan tag and port is configured to accept only tagged frames. This frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br45-source-mac 1.3.6.1.4.1.2007.1.4.74.1.45.1
Parameter 'source-mac' in event BR.45
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br45-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.45.2
Parameter 'dest-mac' in event BR.45
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br45-interface 1.3.6.1.4.1.2007.1.4.74.1.45.3
Parameter 'interface' in event BR.45
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects46 1.3.6.1.4.1.2007.1.4.74.1.46
Event BR.46 A frame has been received, but its VLAN ID is not ingress enabled in the the port bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br46-source-mac 1.3.6.1.4.1.2007.1.4.74.1.46.1
Parameter 'source-mac' in event BR.46
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br46-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.46.2
Parameter 'dest-mac' in event BR.46
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br46-vlan-id 1.3.6.1.4.1.2007.1.4.74.1.46.3
Parameter 'vlan-id' in event BR.46
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

br46-interface 1.3.6.1.4.1.2007.1.4.74.1.46.4
Parameter 'interface' in event BR.46
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects47 1.3.6.1.4.1.2007.1.4.74.1.47
Event BR.47 A frame has been received, but its VLAN ID is not egress enabled in the the port bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br47-source-mac 1.3.6.1.4.1.2007.1.4.74.1.47.1
Parameter 'source-mac' in event BR.47
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br47-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.47.2
Parameter 'dest-mac' in event BR.47
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br47-vlan-id 1.3.6.1.4.1.2007.1.4.74.1.47.3
Parameter 'vlan-id' in event BR.47
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

br47-interface 1.3.6.1.4.1.2007.1.4.74.1.47.4
Parameter 'interface' in event BR.47
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brEventObjects48 1.3.6.1.4.1.2007.1.4.74.1.48
Event BR.48 A frame has been received, but its VLAN ID is not active in the this port bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

br48-source-mac 1.3.6.1.4.1.2007.1.4.74.1.48.1
Parameter 'source-mac' in event BR.48
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br48-dest-mac 1.3.6.1.4.1.2007.1.4.74.1.48.2
Parameter 'dest-mac' in event BR.48
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

br48-vlan-id 1.3.6.1.4.1.2007.1.4.74.1.48.3
Parameter 'vlan-id' in event BR.48
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

br48-interface 1.3.6.1.4.1.2007.1.4.74.1.48.4
Parameter 'interface' in event BR.48
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

brNotification1 1.3.6.1.4.1.2007.1.4.74.2.0.1
Notification of Event BR.1 Message: 'Frame from $1 to $2 dropped, received on blocked or listening port, interface $3' Parameters list: $1: br1-source-mac $2: br1-dest-mac $3: br1-interface A MAC frame has been received by the hardware, but is being dropped because the port it was received on is in the 'blocking' or 'listening' state. Frames are only processed when the port is in the 'learning' or 'forwarding' state.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification2 1.3.6.1.4.1.2007.1.4.74.2.0.2
Notification of Event BR.2 Message: 'Frame from $1 to $2 dropped, destination on same LAN, interface $3' Parameters list: $1: br2-source-mac $2: br2-dest-mac $3: br2-interface A MAC frame has been received whose destination address is known to be on the same side of the bridge as the packet came from. It is dropped by the filtering logic since it does not need to be bridged. Note that this event is not counted by ELS for performance reasons. A counter is kept in ASRT, it is the 'Dropped, dest addr filtering' entry in the ASRT>LIST SOURCE-ROUTE COUNTERS and ASRT>LIST TRANSPARENT COUNTERS commands.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification3 1.3.6.1.4.1.2007.1.4.74.2.0.3
Notification of Event BR.3 Message: 'Frame from $1 a $2, WAN bridge encapsulation for routed protocol IPX (802.3), dropped, interface $3' Parameters list: $1: br3-source-mac $2: br3-dest-mac $3: br3-interface A frame has been received over a WAN interface in the Ethernet bridge encapsulation, but the IPX protocol (in 802.3 encapsulation) is routed by this node.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification4 1.3.6.1.4.1.2007.1.4.74.2.0.4
Notification of Event BR.4 Message: 'Frame from $1 to $2, protocol IPX (802.3) filtered, dropped, interface $3' Parameters list: $1: br4-source-mac $2: br4-dest-mac $3: br4-interface A frame has been received for the IPX protocol (in 802.3 encapsulation), but the IPX protocol is being administratively filtered by the bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification5 1.3.6.1.4.1.2007.1.4.74.2.0.5
Notification of Event BR.5 Message: 'Frame from $1 to $2, IEEE 802 SNAP Protocol Identifier $3-$4-$5-$6-$7 filtered, dropped, interface $8' Parameters list: $1: br5-source-mac $2: br5-dest-mac $3: br5-protocol-identifier $4: br5-protocol-identifier $5: br5-protocol-identifier $6: br5-protocol-identifier $7: br5-protocol-identifier $8: br5-interface A frame has been received for the specified IEEE 802 Subnetwork Access Protocol (SNAP) Protocol Identifier (PID), but this PID is being administratively filtered by the bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification6 1.3.6.1.4.1.2007.1.4.74.2.0.6
Notification of Event BR.6 Message: 'Frame from $1 to unregistered destination MAC address $2, IEEE 802 SNAP Protocol Identifier $3-$4-$5-$6-$7, dropped, interface $8' Parameters list: $1: br6-source-mac $2: br6-dest-mac $3: br6-protocol-identifier $4: br6-protocol-identifier $5: br6-protocol-identifier $6: br6-protocol-identifier $7: br6-protocol-identifier $8: br6-interface A frame has been received for the IEEE 802 Subnetwork Access Protocol (SNAP) Protocol Identifier (PID) which corresponds with an enabled protocol, but the destination MAC address is not registered in the bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification7 1.3.6.1.4.1.2007.1.4.74.2.0.7
Notification of Event BR.7 Message: 'Frame from $1 to $2, IEEE 802 SNAP Protocol Identifier $3-$4-$5-$6-$7 for endnode protocol, interface $8' Parameters list: $1: br7-source-mac $2: br7-dest-mac $3: br7-protocol-identifier $4: br7-protocol-identifier $5: br7-protocol-identifier $6: br7-protocol-identifier $7: br7-protocol-identifier $8: br7-interface A multicast frame has been received for the IEEE 802 Subnetwork Access Protocol (SNAP) Protocol Identifier (PID) which corresponds with an endnode protocol. The frame will be both bridged and locally processed by the endnode protocol.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification8 1.3.6.1.4.1.2007.1.4.74.2.0.8
Notification of Event BR.8 Message: 'Frame from $1 to $2, WAN bridge encapsulation for routed IEEE 802 SNAP Protocol Identifier $3-$4-$5-$6-$7, dropped, interface $8' Parameters list: $1: br8-source-mac $2: br8-dest-mac $3: br8-protocol-identifier $4: br8-protocol-identifier $5: br8-protocol-identifier $6: br8-protocol-identifier $7: br8-protocol-identifier $8: br8-interface An IEEE 802.2 frame has been received over a WAN interface in a bridge encapsulation, but its IEEE 802 Subnetwork Access Protocol (SNAP) Protocol Identifier (PID) is one that is being routed by this node. The frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification9 1.3.6.1.4.1.2007.1.4.74.2.0.9
Notification of Event BR.9 Message: 'IEEE 802.1D BPDU $1 to $2, wrong destination, dropped, interface $3' Parameters list: $1: br9-source-mac $2: br9-dest-mac $3: br9-interface An IEEE 802.1D Bridge Protocol Data Unit (BPDU) was received at the wrong destination address. It is supposed to be addressed to a particular multicast address. The BPDU will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification10 1.3.6.1.4.1.2007.1.4.74.2.0.10
Notification of Event BR.10 Message: 'Frame from $1 to $2, IEEE 802.2 DSAP $3 filtered, dropped, interface $4' Parameters list: $1: br10-source-mac $2: br10-dest-mac $3: br10-destination-service-access-point $4: br10-interface A frame has been received for the specified IEEE 802.2 Destination Service Access Point (DSAP), but this DSAP is being administratively filtered by the bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification11 1.3.6.1.4.1.2007.1.4.74.2.0.11
Notification of Event BR.11 Message: 'Frame from $1 to unregistered destination MAC address $2, IEEE 802.2 DSAP $3, dropped, interface $4' Parameters list: $1: br11-source-mac $2: br11-dest-mac $3: br11-destination-service-access-point $4: br11-interface A frame has been received for the IEEE 802.2 Destination Service Access Point (DSAP) which corresponds with an enabled protocol, but the destination MAC address is not registered in the bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification12 1.3.6.1.4.1.2007.1.4.74.2.0.12
Notification of Event BR.12 Message: 'Frame from $1 to $2, IEEE 802.2 DSAP $3 for endnode protocol, interface $4' Parameters list: $1: br12-source-mac $2: br12-dest-mac $3: br12-destination-service-access-point $4: br12-interface A multicast frame has been received for the IEEE 802.2 Destination Service Access Point (DSAP) which corresponds with an endnode protocol. The frame will be both bridged and locally processed by the endnode protocol.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification13 1.3.6.1.4.1.2007.1.4.74.2.0.13
Notification of Event BR.13 Message: 'Frame from $1 to $2, WAN bridge encapsulation for routed IEEE 802.2 DSAP $3, dropped, interface $4' Parameters list: $1: br13-source-mac $2: br13-dest-mac $3: br13-destination-service-access-point $4: br13-interface An IEEE 802.2 frame has been received over a WAN interface in a bridge encapsulation, but its IEEE 802.2 Destination Service Access Point (DSAP) is one that is being routed by this node. The frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification14 1.3.6.1.4.1.2007.1.4.74.2.0.14
Notification of Event BR.14 Message: 'Frame from $1 to $2, Ethernet type $3 filtered, dropped, interface $4' Parameters list: $1: br14-source-mac $2: br14-dest-mac $3: br14-Ethernet-type $4: br14-interface A frame has been received for the specified Ethernet type, but this type is being administratively filtered by the bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification15 1.3.6.1.4.1.2007.1.4.74.2.0.15
Notification of Event BR.15 Message: 'Frame from $1 to unregistered destination MAC address $2, Ethernet type $3, dropped, interface $4' Parameters list: $1: br15-source-mac $2: br15-dest-mac $3: br15-Ethernet-type $4: br15-interface A frame has been received for the Ethernet type which corresponds with an enabled protocol, but the destination MAC address is not registered in the bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification16 1.3.6.1.4.1.2007.1.4.74.2.0.16
Notification of Event BR.16 Message: 'Frame from $1 to $2, Ethernet type $3 for endnode protocol, interface $4' Parameters list: $1: br16-source-mac $2: br16-dest-mac $3: br16-Ethernet-type $4: br16-interface A multicast frame has been received for the Ethernet type which corresponds with an endnode protocol. The frame will be both bridged and locally processed by the endnode protocol.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification17 1.3.6.1.4.1.2007.1.4.74.2.0.17
Notification of Event BR.17 Message: 'Frame from $1 to $2, WAN bridge encapsulation for routed Ethernet type $3, dropped, interface $4' Parameters list: $1: br17-source-mac $2: br17-dest-mac $3: br17-Ethernet-type $4: br17-interface An Ethernet frame has been received over a WAN interface in the Ethernet bridge encapsulation, but its Ethernet type is one that is being routed by this node. The frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification18 1.3.6.1.4.1.2007.1.4.74.2.0.18
Notification of Event BR.18 Message: 'Source-routed frame from $1 to $2, IEEE 802.2 DSAP $3 filtered, dropped, interface $4' Parameters list: $1: br18-source-mac $2: br18-dest-mac $3: br18-destination-service-access-point $4: br18-interface A source-routed frame has been received for the specified IEEE 802.2 Destination Service Access Point (DSAP), but this DSAP is being administratively filtered by the bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification19 1.3.6.1.4.1.2007.1.4.74.2.0.19
Notification of Event BR.19 Message: 'Source-routed frame from $1 to unregistered destination MAC address $2, IEEE 802.2 DSAP $3, dropped, interface $4' Parameters list: $1: br19-source-mac $2: br19-dest-mac $3: br19-destination-service-access-point $4: br19-interface A source-routed frame has been received for the IEEE 802.2 Destination Service Access Point (DSAP) which corresponds with an enabled protocol, but the destination MAC address is not registered in the bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification20 1.3.6.1.4.1.2007.1.4.74.2.0.20
Notification of Event BR.20 Message: 'Source-routed frame from $1 to $2, IEEE 802.2 DSAP $3 for endnode protocol, interface $4' Parameters list: $1: br20-source-mac $2: br20-dest-mac $3: br20-destination-service-access-point $4: br20-interface A multicast source-routed frame has been received for the IEEE 802.2 Destination Service Access Point (DSAP) which corresponds with an endnode protocol. The frame will be both bridged and locally processed by the endnode protocol.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification21 1.3.6.1.4.1.2007.1.4.74.2.0.21
Notification of Event BR.21 Message: 'Source-routed frame from $1 to $2, IEEE 802 SNAP Protocol Identifier $3-$4-$5-$6-$7 filtered, dropped, interface $8' Parameters list: $1: br21-source-mac $2: br21-dest-mac $3: br21-protocol-identifier $4: br21-protocol-identifier $5: br21-protocol-identifier $6: br21-protocol-identifier $7: br21-protocol-identifier $8: br21-interface A source-routed frame has been received for the specified IEEE 802 Subnetwork Access Protocol (SNAP) Protocol Identifier (PID), but this PID is being administratively filtered by the bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification22 1.3.6.1.4.1.2007.1.4.74.2.0.22
Notification of Event BR.22 Message: 'Source-routed frame from $1 to unregistered destination MAC address $2, IEEE 802 SNAP Protocol Identifier $3-$4-$5-$6-$7, dropped, interface $8' Parameters list: $1: br22-source-mac $2: br22-dest-mac $3: br22-protocol-identifier $4: br22-protocol-identifier $5: br22-protocol-identifier $6: br22-protocol-identifier $7: br22-protocol-identifier $8: br22-interface A source-routed frame has been received for the IEEE 802 Subnetwork Access Protocol (SNAP) Protocol Identifier (PID) which corresponds with an enabled protocol, but the destination MAC address is not registered in the bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification23 1.3.6.1.4.1.2007.1.4.74.2.0.23
Notification of Event BR.23 Message: 'Source-routed frame from $1 to $2 IEEE 802 SNAP Protocol Identifier $3-$4-$5-$6-$7 for endnode protocol, interface $8' Parameters list: $1: br23-source-mac $2: br23-dest-mac $3: br23-protocol-identifier $4: br23-protocol-identifier $5: br23-protocol-identifier $6: br23-protocol-identifier $7: br23-protocol-identifier $8: br23-interface SA source-routed multicast frame has been received for the IEEE 802 Subnetwork Access Protocol (SNAP) Protocol Identifier (PID) which corresponds with an endnode protocol. The frame will be both bridged and locally processed by the endnode protocol.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification24 1.3.6.1.4.1.2007.1.4.74.2.0.24
Notification of Event BR.24 Message: 'VLAN vid $1 not supported. Frame discarded, interface $2' Parameters list: $1: br24-vlan-id $2: br24-interface A vlan frame has been received whose virtual lan id is not supported. Frame is dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification25 1.3.6.1.4.1.2007.1.4.74.2.0.25
Notification of Event BR.25 Message: '---' Reserved for possible future use.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification26 1.3.6.1.4.1.2007.1.4.74.2.0.26
Notification of Event BR.26 Message: 'Frame from $1 to $2 dropped, destination address filtered, interface $3' Parameters list: $1: br26-source-mac $2: br26-dest-mac $3: br26-interface A source-routed MAC frame has been received by the hardware, but is being dropped because the destination MAC address is being administratively filtered by the bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification27 1.3.6.1.4.1.2007.1.4.74.2.0.27
Notification of Event BR.27 Message: 'Frame from $1 to $2 dropped, source address filtered, interface $3' Parameters list: $1: br27-source-mac $2: br27-dest-mac $3: br27-interface A source-routed MAC frame has been received by the hardware, but is being dropped because the source MAC address is being administratively filtered by the bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification28 1.3.6.1.4.1.2007.1.4.74.2.0.28
Notification of Event BR.28 Message: 'No buffer to copy packet for endnode bridge and process, from $1 to $2, interface $3 not bridged' Parameters list: $1: br28-source-mac $2: br28-dest-mac $3: br28-interface A multicast frame has been received for an endnode protocol that is both bridged and locally processed. There was no buffer to make two copies of the frame for both types of processing, so it will not be bridged, only locally processed.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification29 1.3.6.1.4.1.2007.1.4.74.2.0.29
Notification of Event BR.29 Message: 'NETBIOS Input Packet Filtered - $1->$2, port $3, interface $4' Parameters list: $1: br29-source-mac $2: br29-dest-mac $3: br29-port $4: br29-interface A NETBIOS packet has matched the criteria specified in a NETBIOS Filter configuration record. The packet is dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification30 1.3.6.1.4.1.2007.1.4.74.2.0.30
Notification of Event BR.30 Message: 'Updated MAC address for interface $1: $2' Parameters list: $1: br30-interface $2: br30-new-mac The MAC address of a BVI interface has been updated
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification31 1.3.6.1.4.1.2007.1.4.74.2.0.31
Notification of Event BR.31 Message: 'Interface $1 sends a frame from $2 to $3, protocol $4' Parameters list: $1: br31-interface $2: br31-source-mac $3: br31-dest-mac $4: br31-protocol A frame is going to be output to the bridge through a BVI interface.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification32 1.3.6.1.4.1.2007.1.4.74.2.0.32
Notification of Event BR.32 Message: 'Interface $1 has received a frame from $2 to $3, protocol $4' Parameters list: $1: br32-interface $2: br32-source-mac $3: br32-dest-mac $4: br32-protocol A frame has been received in a BVI interface.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification33 1.3.6.1.4.1.2007.1.4.74.2.0.33
Notification of Event BR.33 Message: 'Interface $1 drops frame because interface is down' Parameters list: $1: br33-interface A frame is droped because BVI interface is down
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification34 1.3.6.1.4.1.2007.1.4.74.2.0.34
Notification of Event BR.34 Message: 'Interface $1 sends a frame from $2 to $3, protocol IP' Parameters list: $1: br34-interface $2: br34-source-mac $3: br34-dest-IP-address A frame is dropped because destination IP has no registered MAC address.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification35 1.3.6.1.4.1.2007.1.4.74.2.0.35
Notification of Event BR.35 Message: 'Interface $1 drops frame because protocol $2 is unhandled' Parameters list: $1: br35-interface $2: br35-protocol A frame is droped because BVI interface has no protocol handler
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification36 1.3.6.1.4.1.2007.1.4.74.2.0.36
Notification of Event BR.36 Message: 'Frame from $1 to $2, IEEE 802 SNAP Protocol Identifier $3-$4-$5-$6-$7 not handled, dropped, interface $8' Parameters list: $1: br36-source-mac $2: br36-dest-mac $3: br36-protocol-identifier $4: br36-protocol-identifier $5: br36-protocol-identifier $6: br36-protocol-identifier $7: br36-protocol-identifier $8: br36-interface A frame has been received for the specified IEEE 802 Subnetwork Access Protocol (SNAP) Protocol Identifier (PID), but this PID has no forwarder or endnode support. The frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification37 1.3.6.1.4.1.2007.1.4.74.2.0.37
Notification of Event BR.37 Message: 'Frame from $1 to $2, IEEE 802 SNAP Protocol Identifier $3-$4-$5-$6-$7 dropped, interface $8' Parameters list: $1: br37-source-mac $2: br37-dest-mac $3: br37-protocol-identifier $4: br37-protocol-identifier $5: br37-protocol-identifier $6: br37-protocol-identifier $7: br37-protocol-identifier $8: br37-interface A frame has been received for the specified IEEE 802 Subnetwork Access Protocol (SNAP) Protocol Identifier (PID), but this PID has no enabled bridging nor routing. The frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification38 1.3.6.1.4.1.2007.1.4.74.2.0.38
Notification of Event BR.38 Message: 'Frame from $1 to $2, IEEE 802.2 DSAP $3 not handled, dropped, interface $4' Parameters list: $1: br38-source-mac $2: br38-dest-mac $3: br38-destination-service-access-point $4: br38-interface A frame has been received for the specified IEEE 802.2 Destination Service Access Point (DSAP), but this DSAP has no forwarder or endnode support. The frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification39 1.3.6.1.4.1.2007.1.4.74.2.0.39
Notification of Event BR.39 Message: 'Frame from $1 to $2, IEEE 802.2 DSAP $3, dropped, interface $4' Parameters list: $1: br39-source-mac $2: br39-dest-mac $3: br39-destination-service-access-point $4: br39-interface A frame has been received for the specified IEEE 802.2 Destination Service Access Point (DSAP), but this DSAP has no enabled bridging nor routing. The frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification40 1.3.6.1.4.1.2007.1.4.74.2.0.40
Notification of Event BR.40 Message: 'Frame from $1 to $2, Ethernet type $3 not handled, dropped, interface $4' Parameters list: $1: br40-source-mac $2: br40-dest-mac $3: br40-Ethernet-type $4: br40-interface A frame has been received for the specified Ethernet type, but this type has no forwarder or endnode support. The frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification41 1.3.6.1.4.1.2007.1.4.74.2.0.41
Notification of Event BR.41 Message: 'Frame from $1 to $2, Ethernet type $3 dropped, interface $4' Parameters list: $1: br41-source-mac $2: br41-dest-mac $3: br41-Ethernet-type $4: br41-interface A frame has been received for the specified Ethernet type, but this type has no enabled bridging nor routing. The frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification42 1.3.6.1.4.1.2007.1.4.74.2.0.42
Notification of Event BR.42 Message: 'Source-routed frame from $1 to $2, IEEE 802.2 DSAP $3 dropped, interface $4' Parameters list: $1: br42-source-mac $2: br42-dest-mac $3: br42-destination-service-access-point $4: br42-interface A source-routed frame has been received for the specified IEEE 802.2 Destination Service Access Point (DSAP), but this DSAP has no enabled bridging nor routing. The frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification43 1.3.6.1.4.1.2007.1.4.74.2.0.43
Notification of Event BR.43 Message: 'Source-routed frame from $1 to $2, IEEE 802 SNAP Protocol Identifier $3-$4-$5-$6-$7 dropped, interface $8' Parameters list: $1: br43-source-mac $2: br43-dest-mac $3: br43-protocol-identifier $4: br43-protocol-identifier $5: br43-protocol-identifier $6: br43-protocol-identifier $7: br43-protocol-identifier $8: br43-interface A source-routed frame has been received for the specified IEEE 802 Subnetwork Access Protocol (SNAP) Protocol Identifier (PID), but this PID has no enabled bridging nor routing. The frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification44 1.3.6.1.4.1.2007.1.4.74.2.0.44
Notification of Event BR.44 Message: 'Frame from $1 to $2, with VID FFF dropped, interface $3' Parameters list: $1: br44-source-mac $2: br44-dest-mac $3: br44-interface A frame has been received with vlan identifier FFF. This frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification45 1.3.6.1.4.1.2007.1.4.74.2.0.45
Notification of Event BR.45 Message: 'Frame without vlan tag from $1 to $2, dropped, interface $3' Parameters list: $1: br45-source-mac $2: br45-dest-mac $3: br45-interface A frame has been received with no vlan tag and port is configured to accept only tagged frames. This frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification46 1.3.6.1.4.1.2007.1.4.74.2.0.46
Notification of Event BR.46 Message: 'Frame dropped from $1 to $2, vlan ID $3, ingress not enabled on interface $4' Parameters list: $1: br46-source-mac $2: br46-dest-mac $3: br46-vlan-id $4: br46-interface A frame has been received, but its VLAN ID is not ingress enabled in the the port bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification47 1.3.6.1.4.1.2007.1.4.74.2.0.47
Notification of Event BR.47 Message: 'Frame dropped from $1 to $2, vlan ID $3 egress not enabled on interface $4' Parameters list: $1: br47-source-mac $2: br47-dest-mac $3: br47-vlan-id $4: br47-interface A frame has been received, but its VLAN ID is not egress enabled in the the port bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brNotification48 1.3.6.1.4.1.2007.1.4.74.2.0.48
Notification of Event BR.48 Message: 'Frame dropped from $1 to $2, vlan ID $3 egress filt, not active on interface $4' Parameters list: $1: br48-source-mac $2: br48-dest-mac $3: br48-vlan-id $4: br48-interface A frame has been received, but its VLAN ID is not active in the this port bridge. The frame will be dropped.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE