SPC200

File: SPC200.mib (149415 bytes)

Imported modules

SNMPv2-TC SNMPv2-CONF SNMPv2-SMI
IF-MIB SPIDCOM-MIB

Imported symbols

RowStatus TruthValue MacAddress
DisplayString TEXTUAL-CONVENTION AGENT-CAPABILITIES
OBJECT-GROUP MODULE-COMPLIANCE MODULE-IDENTITY
OBJECT-IDENTITY OBJECT-TYPE Integer32
Counter32 IpAddress Unsigned32
Gauge32 interfaces ifIndex
spidcom

Defined Types

ModulationValue  
Modulation amplitude used by a group of carriers.
TEXTUAL-CONVENTION    
  INTEGER none(1), bpsk(2), qpsk(3), qam16(4), qam64(5), qam256(6)  

CarrierValue  
A group is composed of 8 carriers.
TEXTUAL-CONVENTION    
  Integer32 1..8  

PilotValue  
The pilot carrier wave can be chosen between the carrier 1 up to carrier 128 inside a band carrier range.
TEXTUAL-CONVENTION    
  Integer32 1..128  

BandValue  
A channel is composed of 7 bands.
TEXTUAL-CONVENTION    
  Integer32 1..7  

PlcChannelType  
The different type of plc channels: rx for the current reception channel, rx last for the last reception channel, tx for the current transmission channel.
TEXTUAL-CONVENTION    
  INTEGER rx(1), rxLast(2), tx(3)  

EstimationMode  
The type of Channel estimation process. Two are available: - automatic, the equipment negociates the best configuration with the remote equipment, - manual, the operator defines the configuration.
TEXTUAL-CONVENTION    
  INTEGER automatic(1), manual(2)  

GroupValue  
A band is composed of 16 groups.
TEXTUAL-CONVENTION    
  Integer32 1..16  

ResultValue  
Result value of input vectors.
TEXTUAL-CONVENTION    
  INTEGER success(1), fail(2)  

AdaptValue  
The adapt level integer value.
TEXTUAL-CONVENTION    
  Integer32 0..8191  

ChannelBandwidthValue  
The channel bandwidth integer value.
TEXTUAL-CONVENTION    
  Integer32  

SoftwareIndex  
The software index.
TEXTUAL-CONVENTION    
  Integer32 1..10  

SoftwareActionResultValue  
Result value of software action process.
TEXTUAL-CONVENTION    
  INTEGER success(0), on-going(1), fileNotExist(2), flashExhausted(3), flashCorrupted(4), notEnoughMemory(5), invalidParameter(6), genericError(7)  

SoftwareActionType  
Type of software management action.
TEXTUAL-CONVENTION    
  INTEGER switch(1), remove(2)  

PlcModeType  
Type of software management action.
TEXTUAL-CONVENTION    
  INTEGER ad-hoc(0), slave(1), master(2)  

PortStatsEntry  
SEQUENCE    
  portStatsBandIndex BandValue
  portStatsGroupIndex GroupValue
  portStatsCarrierIndex CarrierValue
  portStatsSignal Counter32
  portStatsNoise Counter32

PortStats2Entry  
SEQUENCE    
  portStats2Signal OCTET STRING
  portStats2Noise OCTET STRING
  portStats2AvgBandAtt Counter32
  portStats2AvgBandSNR Counter32

PortStats3Entry  
SEQUENCE    
  portStats3AvgAtt Counter32
  portStats3AvgSNR Counter32

PlcSNAnalyserEntry  
SEQUENCE    
  plcSNAnalyserMinSignal OCTET STRING
  plcSNAnalyserMaxSignal OCTET STRING
  plcSNAnalyserAvgSignal OCTET STRING
  plcSNAnalyserLastSignal OCTET STRING
  plcSNAnalyserFFTDiv Counter32

PlcBasePortEntry  
SEQUENCE    
  plcBasePortIndex MacAddress
  plcBasePortAddress MacAddress
  plcBasePortChannelEstimation EstimationMode
  plcBasePortAttenuation Counter32

PlcChannelModulationStringEntry  
SEQUENCE    
  plcRxChannelModulation OCTET STRING
  plcRxLastChannelModulation OCTET STRING
  plcTxChannelModulation OCTET STRING

PlcChannelModulationEntry  
SEQUENCE    
  plcModBandIndex BandValue
  plcModGroup1 ModulationValue
  plcModGroup2 ModulationValue
  plcModGroup3 ModulationValue
  plcModGroup4 ModulationValue
  plcModGroup5 ModulationValue
  plcModGroup6 ModulationValue
  plcModGroup7 ModulationValue
  plcModGroup8 ModulationValue
  plcModGroup9 ModulationValue
  plcModGroup10 ModulationValue
  plcModGroup11 ModulationValue
  plcModGroup12 ModulationValue
  plcModGroup13 ModulationValue
  plcModGroup14 ModulationValue
  plcModGroup15 ModulationValue
  plcModGroup16 ModulationValue

PlcPortChannelEntry  
SEQUENCE    
  plcPortChannelIndex Unsigned32
  plcPortChannelType PlcChannelType
  plcPortChannelGain Integer32
  plcPortChannelBandwidth ChannelBandwidthValue
  plcPortChannelMaxBandwidth ChannelBandwidthValue
  plcPortChannelSynchronizationBand BandValue

PlcChannelPilotStringEntry  
SEQUENCE    
  plcRxChannelPilots OCTET STRING
  plcRxLastChannelPilots OCTET STRING
  plcTxChannelPilots OCTET STRING

PlcChannelPilotsEntry  
SEQUENCE    
  plcChannelPilotBandIndex BandValue
  plcChannelPilot1 PilotValue
  plcChannePilot2 PilotValue

PlcNodeNotchesEntry  
SEQUENCE    
  plcNodeNotchesBandIndex BandValue
  plcNodeNotchesGroupIndex GroupValue
  plcNodeNotchesCarrier1 TruthValue
  plcNodeNotchesCarrier2 TruthValue
  plcNodeNotchesCarrier3 TruthValue
  plcNodeNotchesCarrier4 TruthValue
  plcNodeNotchesCarrier5 TruthValue
  plcNodeNotchesCarrier6 TruthValue
  plcNodeNotchesCarrier7 TruthValue
  plcNodeNotchesCarrier8 TruthValue

PlcNodePilotsEntry  
SEQUENCE    
  plcNodePilotsBandIndex BandValue
  plcNodePilot1 PilotValue
  plcNodePilot2 PilotValue

PlcNodeAdaptsStringEntry  
SEQUENCE    
  plcNodeAdaptsStringBandIndex BandValue
  plcNodeAdaptsStringBand OCTET STRING

PlcNodeAdaptsEntry  
SEQUENCE    
  plcNodeAdaptsBandIndex BandValue
  plcNodeAdaptsGroupIndex GroupValue
  plcNodeAdaptsCarrier1 AdaptValue
  plcNodeAdaptsCarrier2 AdaptValue
  plcNodeAdaptsCarrier3 AdaptValue
  plcNodeAdaptsCarrier4 AdaptValue
  plcNodeAdaptsCarrier5 AdaptValue
  plcNodeAdaptsCarrier6 AdaptValue
  plcNodeAdaptsCarrier7 AdaptValue
  plcNodeAdaptsCarrier8 AdaptValue

PlcNodeNetConfigEntry  
SEQUENCE    
  plcNodeIpAddr IpAddress
  plcNodeNetMask IpAddress
  plcNodeMacAddr MacAddress
  plcNodeGateway IpAddress

SoftwareEntry  
SEQUENCE    
  softwareIndex SoftwareIndex
  softwareVersion DisplayString

Defined Values

spc200MIB 1.3.6.1.4.1.22764.1
Description
MODULE-IDENTITY    

plc 1.3.6.1.4.1.22764.1.1
OBJECT IDENTIFIER    

stats 1.3.6.1.4.1.22764.1.1.1
OBJECT IDENTIFIER    

portStatsTable 1.3.6.1.4.1.22764.1.1.1.2
This table gathers all statistic data specific to SPC200 chip relative to plc connection.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PortStatsEntry

portStatsEntry 1.3.6.1.4.1.22764.1.1.1.2.1
This row contains statistic data specific to SPC200 chip relative to a connection.
Status: current Access: not-accessible
OBJECT-TYPE    
  PortStatsEntry  

portStatsBandIndex 1.3.6.1.4.1.22764.1.1.1.2.1.1
The band number on which the signal, noise, ber data are collected.
Status: current Access: not-accessible
OBJECT-TYPE    
  BandValue  

portStatsGroupIndex 1.3.6.1.4.1.22764.1.1.1.2.1.2
The group number on which the signal, noise, ber data are collected
Status: current Access: not-accessible
OBJECT-TYPE    
  GroupValue  

portStatsCarrierIndex 1.3.6.1.4.1.22764.1.1.1.2.1.3
The group number on which the signal, noise, ber data are collected
Status: current Access: not-accessible
OBJECT-TYPE    
  CarrierValue  

portStatsSignal 1.3.6.1.4.1.22764.1.1.1.2.1.4
The DB value of the signal associated with the carrier wave entry.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

portStatsNoise 1.3.6.1.4.1.22764.1.1.1.2.1.5
The DB value of the noise associated with the carrier wave entry.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

portStats2Table 1.3.6.1.4.1.22764.1.1.1.3
This table gathers all statistic data specific to SPC200 chip relative to plc channels. This table has the same information as the portChannelStatsTable but in a more compact way. This table has been added to deal with possible slow performances.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PortStats2Entry

portStats2Entry 1.3.6.1.4.1.22764.1.1.1.3.1
This row contains statistic data specific to SPC200 chip relative to a connection.
Status: current Access: not-accessible
OBJECT-TYPE    
  PortStats2Entry  

portStats2Signal 1.3.6.1.4.1.22764.1.1.1.3.1.1
The values of the signal for all the carrier waves. The expected format is VALUE VALUE VALUE ... VALUE. Each value is coded on two bytes. There is one value for each 128 carriers of the considered band.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

portStats2Noise 1.3.6.1.4.1.22764.1.1.1.3.1.2
The values of the noise for all the carrier waves. The expected format is VALUE VALUE VALUE ... VALUE. Each value is coded on two bytes. There is one value for each 128 carriers of the considered band.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

portStats2AvgBandAtt 1.3.6.1.4.1.22764.1.1.1.3.1.3
Average attenuation per band (dB).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

portStats2AvgBandSNR 1.3.6.1.4.1.22764.1.1.1.3.1.4
Average SNR per band (dB).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

portStats3Table 1.3.6.1.4.1.22764.1.1.1.4
This table gathers all statistic data specific to SPC200 chip relative to plc channels. This table has the same information as the portChannelStatsTable but in a more compact way. This table has been added to deal with possible slow performances.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PortStats3Entry

portStats3Entry 1.3.6.1.4.1.22764.1.1.1.4.1
This row contains statistic data specific to SPC200 chip relative to a connection.
Status: current Access: not-accessible
OBJECT-TYPE    
  PortStats3Entry  

portStats3AvgAtt 1.3.6.1.4.1.22764.1.1.1.4.1.1
Average attenuation on the link (dB).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

portStats3AvgSNR 1.3.6.1.4.1.22764.1.1.1.4.1.2
Average SNR on the link (dB).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

bootstats 1.3.6.1.4.1.22764.1.1.1.5
boot statistics
Status: current Access: read-only
OBJECT-IDENTITY    

bootstatsBoot 1.3.6.1.4.1.22764.1.1.1.5.1
Boot
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

bootstatsManualReset 1.3.6.1.4.1.22764.1.1.1.5.2
Manual reset
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

bootstatsFailureReset 1.3.6.1.4.1.22764.1.1.1.5.3
Failure reset
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

plcObjects 1.3.6.1.4.1.22764.1.1.2
OBJECT IDENTIFIER    

plcMode 1.3.6.1.4.1.22764.1.1.2.1
Plc Mode
Status: current Access: read-write
OBJECT-TYPE    
  PlcModeType  

plcTopo 1.3.6.1.4.1.22764.1.1.2.2
OBJECT IDENTIFIER    

plcNodeConfiguration 1.3.6.1.4.1.22764.1.1.2.3
OBJECT IDENTIFIER    

plcSNAnalyser 1.3.6.1.4.1.22764.1.1.2.4
OBJECT IDENTIFIER    

plcSNAnalyserEnable 1.3.6.1.4.1.22764.1.1.2.4.1
true if the modem should turn to spectrum analyser mode. In this mode the modem enters a receive only mode, and captures periodic samples of the signal on the powerline. The spectrum analyser mode shall be disabled for normal powerline modem operation.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER true(1), false(2)  

plcSNAnalyserTable 1.3.6.1.4.1.22764.1.1.2.4.2
This table gathers all statistic data specific to SPC200 chip relative to plc analyser.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PlcSNAnalyserEntry

plcSNAnalyserEntry 1.3.6.1.4.1.22764.1.1.2.4.2.1
This row contains statistic data specific to SPC200 chip relative to a band.
Status: current Access: not-accessible
OBJECT-TYPE    
  PlcSNAnalyserEntry  

plcSNAnalyserMinSignal 1.3.6.1.4.1.22764.1.1.2.4.2.1.1
Minimum signal measured over several samples for the associated carrier wave entry. The value is expressed in Glomer which can be converted in dBm/Hz using the following formula: dBm/Hz = 19*log10(Glomer) - 113
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

plcSNAnalyserMaxSignal 1.3.6.1.4.1.22764.1.1.2.4.2.1.2
Maximum signal measured on several samples for the associated carrier wave entry. The value is expressed in Glomer which can be converted in dBm/Hz using the following formula: dBm/Hz = 19*log10(Glomer) - 113
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

plcSNAnalyserAvgSignal 1.3.6.1.4.1.22764.1.1.2.4.2.1.3
Average signal measured on several samples for the associated carrier wave entry. The value is expressed in Glomer which can be converted in dBm/Hz using the following formula: dBm/Hz = 19*log10(Glomer) - 113
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

plcSNAnalyserLastSignal 1.3.6.1.4.1.22764.1.1.2.4.2.1.4
Signal measured for last sample on the associated carrier wave entry. The value is expressed in Glomer which can be converted in dBm/Hz using the following formula: dBm/Hz = 19*log10(Glomer) - 113
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

plcSNAnalyserFFTDiv 1.3.6.1.4.1.22764.1.1.2.4.2.1.5
FFT division factor on the associated band.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

plcSNAnalyserAGC 1.3.6.1.4.1.22764.1.1.2.4.3
Gain factor in dB, as used by the Automatic Gain Control last sample
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

plcAGCAnalyser 1.3.6.1.4.1.22764.1.1.2.5
OBJECT IDENTIFIER    

plcAGCAnalyserEnable 1.3.6.1.4.1.22764.1.1.2.5.1
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER true(1), false(2)  

plcAGCAnalyserSamplesPart1 1.3.6.1.4.1.22764.1.1.2.5.2
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

plcAGCAnalyserSamplesPart2 1.3.6.1.4.1.22764.1.1.2.5.3
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

plcTopoChanges 1.3.6.1.4.1.22764.1.1.2.2.1
The total number of topology changes detected by this plc bridge since the management entity was last reset or initialized. Such changes concerns only - the plcBasePortTable rows - the plcBasePortTable columns except for plcBasePortChannelEstimation
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

plcBasePortTable 1.3.6.1.4.1.22764.1.1.2.2.2
This table contains the list of plc remote connection
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PlcBasePortEntry

plcBasePortEntry 1.3.6.1.4.1.22764.1.1.2.2.2.1
This row contains plc remote connection information
Status: current Access: not-accessible
OBJECT-TYPE    
  PlcBasePortEntry  

plcBasePortIndex 1.3.6.1.4.1.22764.1.1.2.2.2.1.1
The MAC address of the MAC layer above the plc interface of the remote PLC equipment.
Status: current Access: not-accessible
OBJECT-TYPE    
  MacAddress  

plcBasePortAddress 1.3.6.1.4.1.22764.1.1.2.2.2.1.2
The MAC address of the MAC layer above the plc interface of the remote PLC equipment.
Status: current Access: read-only
OBJECT-TYPE    
  MacAddress  

plcBasePortChannelEstimation 1.3.6.1.4.1.22764.1.1.2.2.2.1.3
Enable or disable the automatic channel estimation processus.
Status: current Access: read-write
OBJECT-TYPE    
  EstimationMode  

plcBasePortAttenuation 1.3.6.1.4.1.22764.1.1.2.2.2.1.4
Link attenuation (dB).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

plcChannelModulationStringTable 1.3.6.1.4.1.22764.1.1.2.2.3
This table contains string values for a quick access to the modulation amplitude configurations of all active channels.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PlcChannelModulationStringEntry

plcChannelModulationStringEntry 1.3.6.1.4.1.22764.1.1.2.2.3.1
This row contains string values for a quick access to the modulation amplitude configuration of each active channel of the remote connection referenced by plcBasePortIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  PlcChannelModulationStringEntry  

plcRxChannelModulation 1.3.6.1.4.1.22764.1.1.2.2.3.1.1
The modulation amplitude values for the Rx channel of a given remote connection entry. The expected format is VALUE VALUE VALUE ... VALUE. Each value is an octet representing two modulation values. Each modulation is coded on 4 bits. There are ( 16 groups * 7 bands ) / 2 = 66 values.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

plcRxLastChannelModulation 1.3.6.1.4.1.22764.1.1.2.2.3.1.2
The modulation amplitude values for the Rx Last channel of a given remote connection entry. The expected format is VALUE VALUE VALUE ... VALUE. Each value is an octet representing two modulation values. Each modulation is coded on 4 bits representing ModulationValue - 1. There are ( 16 groups * 7 bands ) / 2 = 66 values.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

plcTxChannelModulation 1.3.6.1.4.1.22764.1.1.2.2.3.1.3
The modulation amplitude values for the Tx channel of a given remote connection entry. The expected format is VALUE VALUE VALUE ... VALUE. Each value is an octet representing two modulation values. Each modulation is coded on 4 bits. There are ( 16 groups * 7 bands ) / 2 = 66 values.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

plcChannelModulationTable 1.3.6.1.4.1.22764.1.1.2.2.4
This table contains the modulation amplitude configuration of all active channels.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PlcChannelModulationEntry

plcChannelModulationEntry 1.3.6.1.4.1.22764.1.1.2.2.4.1
This row contains modulation amplitude configuration of the channel, referenced by the plcPortChannelIndex, of the remote connection referenced by plcBasePortIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  PlcChannelModulationEntry  

plcModBandIndex 1.3.6.1.4.1.22764.1.1.2.2.4.1.1
The band number of which the modulations are defined
Status: current Access: not-accessible
OBJECT-TYPE    
  BandValue  

plcModGroup1 1.3.6.1.4.1.22764.1.1.2.2.4.1.2
The modulation amplitude of the first group of the band entry of the channel entry for a given remote connection entry.
Status: current Access: read-only
OBJECT-TYPE    
  ModulationValue  

plcModGroup2 1.3.6.1.4.1.22764.1.1.2.2.4.1.3
The modulation amplitude of the second group of the band entry of the channel entry for a given remote connection entry.
Status: current Access: read-only
OBJECT-TYPE    
  ModulationValue  

plcModGroup3 1.3.6.1.4.1.22764.1.1.2.2.4.1.4
The modulation amplitude of the third group of the band entry of the channel entry for a given remote connection entry.
Status: current Access: read-only
OBJECT-TYPE    
  ModulationValue  

plcModGroup4 1.3.6.1.4.1.22764.1.1.2.2.4.1.5
The modulation amplitude of the fourth group of the band entry of the channel entry for a given remote connection entry.
Status: current Access: read-only
OBJECT-TYPE    
  ModulationValue  

plcModGroup5 1.3.6.1.4.1.22764.1.1.2.2.4.1.6
The modulation amplitude of the fifth group of the band entry of the channel entry for a given remote connection entry.
Status: current Access: read-only
OBJECT-TYPE    
  ModulationValue  

plcModGroup6 1.3.6.1.4.1.22764.1.1.2.2.4.1.7
The modulation amplitude of the sixth group of the band entry of the channel entry for a given remote connection entry.
Status: current Access: read-only
OBJECT-TYPE    
  ModulationValue  

plcModGroup7 1.3.6.1.4.1.22764.1.1.2.2.4.1.8
The modulation amplitude of the seventh group of the band entry of the channel entry for a given remote connection entry.
Status: current Access: read-only
OBJECT-TYPE    
  ModulationValue  

plcModGroup8 1.3.6.1.4.1.22764.1.1.2.2.4.1.9
The modulation amplitude of the eighth group of the band entry of the channel entry for a given remote connection entry.
Status: current Access: read-only
OBJECT-TYPE    
  ModulationValue  

plcModGroup9 1.3.6.1.4.1.22764.1.1.2.2.4.1.10
The modulation amplitude of the nineth group of the band entry of the channel entry for a given remote connection entry.
Status: current Access: read-only
OBJECT-TYPE    
  ModulationValue  

plcModGroup10 1.3.6.1.4.1.22764.1.1.2.2.4.1.11
The modulation amplitude of the tenth group of the band entry of the channel entry for a given remote connection entry.
Status: current Access: read-only
OBJECT-TYPE    
  ModulationValue  

plcModGroup11 1.3.6.1.4.1.22764.1.1.2.2.4.1.12
The modulation amplitude of the eleventh group of the band entry of the channel entry for a given remote connection entry.
Status: current Access: read-only
OBJECT-TYPE    
  ModulationValue  

plcModGroup12 1.3.6.1.4.1.22764.1.1.2.2.4.1.13
The modulation amplitude of the twelveth group of the band entry of the channel entry for a given remote connection entry.
Status: current Access: read-only
OBJECT-TYPE    
  ModulationValue  

plcModGroup13 1.3.6.1.4.1.22764.1.1.2.2.4.1.14
The modulation amplitude of the thirteenth group of the band entry of the channel entry for a given remote connection entry.
Status: current Access: read-only
OBJECT-TYPE    
  ModulationValue  

plcModGroup14 1.3.6.1.4.1.22764.1.1.2.2.4.1.15
The modulation amplitude of the fourteenth group of the band entry of the channel entry for a given remote connection entry.
Status: current Access: read-only
OBJECT-TYPE    
  ModulationValue  

plcModGroup15 1.3.6.1.4.1.22764.1.1.2.2.4.1.16
The modulation amplitude of the fifteenth group of the band entry of the channel entry for a given remote connection entry.
Status: current Access: read-only
OBJECT-TYPE    
  ModulationValue  

plcModGroup16 1.3.6.1.4.1.22764.1.1.2.2.4.1.17
The modulation amplitude of the sixteenth group of the band entry of the channel entry for a given remote connection entry.
Status: current Access: read-only
OBJECT-TYPE    
  ModulationValue  

plcChannelModulationInput 1.3.6.1.4.1.22764.1.1.2.2.5
OBJECT IDENTIFIER    

plcModulationInputAddr 1.3.6.1.4.1.22764.1.1.2.2.5.1
The MAC address of the MAC layer above the plc interface of the remote PLC equipment for which the modulation value changes are requested.
Status: current Access: read-write
OBJECT-TYPE    
  MacAddress  

plcModulationInputChannel 1.3.6.1.4.1.22764.1.1.2.2.5.2
The channel type of the remote PLC equipment for which the modulation value changes are requested.
Status: current Access: read-write
OBJECT-TYPE    
  PlcChannelType  

plcModulationInputBand 1.3.6.1.4.1.22764.1.1.2.2.5.3
The band number of which the modulation value changes are requested.
Status: current Access: read-write
OBJECT-TYPE    
  BandValue  

plcInputModulationGroup1 1.3.6.1.4.1.22764.1.1.2.2.5.4
The new requested modulation amplitude of the first group of the considered band and channel input values.
Status: current Access: read-write
OBJECT-TYPE    
  ModulationValue  

plcInputModulationGroup2 1.3.6.1.4.1.22764.1.1.2.2.5.5
The new requested modulation amplitude of the second group of the considered band and channel input values.
Status: current Access: read-write
OBJECT-TYPE    
  ModulationValue  

plcInputModulationGroup3 1.3.6.1.4.1.22764.1.1.2.2.5.6
The new requested modulation amplitude of the third group of the considered band and channel input values.
Status: current Access: read-write
OBJECT-TYPE    
  ModulationValue  

plcInputModulationGroup4 1.3.6.1.4.1.22764.1.1.2.2.5.7
The new requested modulation amplitude of the fourth group of the considered band and channel input values.
Status: current Access: read-write
OBJECT-TYPE    
  ModulationValue  

plcInputModulationGroup5 1.3.6.1.4.1.22764.1.1.2.2.5.8
The new requested modulation amplitude of the fifth group of the considered band and channel input values.
Status: current Access: read-write
OBJECT-TYPE    
  ModulationValue  

plcInputModulationGroup6 1.3.6.1.4.1.22764.1.1.2.2.5.9
The new requested modulation amplitude of the sixth group of the considered band and channel input values.
Status: current Access: read-write
OBJECT-TYPE    
  ModulationValue  

plcInputModulationGroup7 1.3.6.1.4.1.22764.1.1.2.2.5.10
The new requested modulation amplitude of the seventh group of the considered band and channel input values.
Status: current Access: read-write
OBJECT-TYPE    
  ModulationValue  

plcInputModulationGroup8 1.3.6.1.4.1.22764.1.1.2.2.5.11
The new requested modulation amplitude of the eighth group of the considered band and channel input values.
Status: current Access: read-write
OBJECT-TYPE    
  ModulationValue  

plcInputModulationGroup9 1.3.6.1.4.1.22764.1.1.2.2.5.12
The new requested modulation amplitude of the nineth group of the considered band and channel input values.
Status: current Access: read-write
OBJECT-TYPE    
  ModulationValue  

plcInputModulationGroup10 1.3.6.1.4.1.22764.1.1.2.2.5.13
The new requested modulation amplitude of the tenth group of the considered band and channel input values.
Status: current Access: read-write
OBJECT-TYPE    
  ModulationValue  

plcInputModulationGroup11 1.3.6.1.4.1.22764.1.1.2.2.5.14
The new requested modulation amplitude of the eleventh group of the considered band and channel input values.
Status: current Access: read-write
OBJECT-TYPE    
  ModulationValue  

plcInputModulationGroup12 1.3.6.1.4.1.22764.1.1.2.2.5.15
The new requested modulation amplitude of the twelveth group of the considered band and channel input values.
Status: current Access: read-write
OBJECT-TYPE    
  ModulationValue  

plcInputModulationGroup13 1.3.6.1.4.1.22764.1.1.2.2.5.16
The new requested modulation amplitude of the thirteenth group of the considered band and channel input values.
Status: current Access: read-write
OBJECT-TYPE    
  ModulationValue  

plcInputModulationGroup14 1.3.6.1.4.1.22764.1.1.2.2.5.17
The new requested modulation amplitude of the fourteenth group of the considered band and channel input values.
Status: current Access: read-write
OBJECT-TYPE    
  ModulationValue  

plcInputModulationGroup15 1.3.6.1.4.1.22764.1.1.2.2.5.18
The new requested modulation amplitude of the fifteenth group of the considered band and channel input values.
Status: current Access: read-write
OBJECT-TYPE    
  ModulationValue  

plcInputModulationGroup16 1.3.6.1.4.1.22764.1.1.2.2.5.19
The new requested modulation amplitude of the sixteenth group of the considered band and channel input values.
Status: current Access: read-write
OBJECT-TYPE    
  ModulationValue  

plcModulationInputProceed 1.3.6.1.4.1.22764.1.1.2.2.5.20
True to request a modification of all the modulations associated to a band and a channel of a remote PLC equipment.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

plcModulationInputResult 1.3.6.1.4.1.22764.1.1.2.2.5.21
Result value of the requested modulation value changes.
Status: current Access: read-only
OBJECT-TYPE    
  ResultValue  

plcPortChannelTable 1.3.6.1.4.1.22764.1.1.2.2.6
This table contains the list of plc channels
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PlcPortChannelEntry

plcPortChannelEntry 1.3.6.1.4.1.22764.1.1.2.2.6.1
This row contains plc channel information
Status: current Access: not-accessible
OBJECT-TYPE    
  PlcPortChannelEntry  

plcPortChannelIndex 1.3.6.1.4.1.22764.1.1.2.2.6.1.1
The channel number belongs to the remote connection with plc equipment associated with the plcBasePortIndex value. Only three channels are expected. Index 1 for RX channel Index 2 for RXLast channel index 3 for TX channel
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

plcPortChannelType 1.3.6.1.4.1.22764.1.1.2.2.6.1.2
The channel type.
Status: current Access: read-only
OBJECT-TYPE    
  PlcChannelType  

plcPortChannelGain 1.3.6.1.4.1.22764.1.1.2.2.6.1.3
The gain associated with the channel.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

plcPortChannelBandwidth 1.3.6.1.4.1.22764.1.1.2.2.6.1.4
The bandwidth of the channel in Kbit/s.
Status: current Access: read-only
OBJECT-TYPE    
  ChannelBandwidthValue  

plcPortChannelMaxBandwidth 1.3.6.1.4.1.22764.1.1.2.2.6.1.5
The maximum bandwidth of the channel in Kbit/s.
Status: current Access: read-only
OBJECT-TYPE    
  ChannelBandwidthValue  

plcPortChannelSynchronizationBand 1.3.6.1.4.1.22764.1.1.2.2.6.1.6
The synchronization band used for this channel.
Status: current Access: read-only
OBJECT-TYPE    
  BandValue  

plcChannelPilotStringTable 1.3.6.1.4.1.22764.1.1.2.2.7
This table contains the string values representing of pilot values of all active channels.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PlcChannelPilotStringEntry

plcChannelPilotStringEntry 1.3.6.1.4.1.22764.1.1.2.2.7.1
This row contains a quick access for pilot values , of the remote connection referenced by plcBasePortIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  PlcChannelPilotStringEntry  

plcRxChannelPilots 1.3.6.1.4.1.22764.1.1.2.2.7.1.1
The carrier wave numbers which support the pilot waves for the Rx Channel. The expected format is VALUE VALUE VALUE ... VALUE. Each value is a pair of octets representing the pilot values. There is one pair (pilot1 pilot2) for each of the 7 bands.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

plcRxLastChannelPilots 1.3.6.1.4.1.22764.1.1.2.2.7.1.2
The carrier wave numbers which support the pilot waves for the Rx Last Channel. The expected format is VALUE VALUE VALUE ... VALUE. Each value is a pair of octets representing the pilot values. There is one pair (pilot1 pilot2) for each of the 7 bands.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

plcTxChannelPilots 1.3.6.1.4.1.22764.1.1.2.2.7.1.3
The carrier wave numbers which support the pilot waves for the Tx Channel. The expected format is VALUE VALUE VALUE ... VALUE. Each value is a pair of octets representing the pilot values. There is one pair (pilot1 pilot2) for each of the 7 bands.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

plcChannelPilotsTable 1.3.6.1.4.1.22764.1.1.2.2.8
This tabel contains pilots configuration for each plc channel.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PlcChannelPilotsEntry

plcChannelPilotsEntry 1.3.6.1.4.1.22764.1.1.2.2.8.1
This row contains the pilots 1 and 2 configuration for a channel defined by the couple (plcBasePortIndex, plcPortChannelIndex)
Status: current Access: not-accessible
OBJECT-TYPE    
  PlcChannelPilotsEntry  

plcChannelPilotBandIndex 1.3.6.1.4.1.22764.1.1.2.2.8.1.1
The band number on which the pilots are defined.
Status: current Access: not-accessible
OBJECT-TYPE    
  BandValue  

plcChannelPilot1 1.3.6.1.4.1.22764.1.1.2.2.8.1.2
The carrier wave number which supports the first pilot wave for the channel associated with this entry.
Status: current Access: read-only
OBJECT-TYPE    
  PilotValue  

plcChannePilot2 1.3.6.1.4.1.22764.1.1.2.2.8.1.3
The carrier wave number which supports the second pilot wave for the channel associated with this entry.
Status: current Access: read-only
OBJECT-TYPE    
  PilotValue  

plcChannelPilotsInput 1.3.6.1.4.1.22764.1.1.2.2.9
OBJECT IDENTIFIER    

plcPilotsInputAddr 1.3.6.1.4.1.22764.1.1.2.2.9.1
The MAC address of the MAC layer above the plc interface of the remote PLC equipment for which the pilot value changes are requested.
Status: current Access: read-write
OBJECT-TYPE    
  MacAddress  

plcPilotsInputChannel 1.3.6.1.4.1.22764.1.1.2.2.9.2
The channel type of the remote PLC equipment for which the pilot value changes are requested.
Status: current Access: read-write
OBJECT-TYPE    
  PlcChannelType  

plcPilotsInputBand 1.3.6.1.4.1.22764.1.1.2.2.9.3
The band number of which the pilots value changes are requested.
Status: current Access: read-write
OBJECT-TYPE    
  BandValue  

plcInputChannelPilot1 1.3.6.1.4.1.22764.1.1.2.2.9.4
The carrier wave number which supports the first pilot wave for the considered band and channel input values.
Status: current Access: read-write
OBJECT-TYPE    
  PilotValue  

plcInputChannelPilot2 1.3.6.1.4.1.22764.1.1.2.2.9.5
The carrier wave number which supports the second pilot wave for the considered band and channel input values.
Status: current Access: read-write
OBJECT-TYPE    
  PilotValue  

plcPilotsInputProceed 1.3.6.1.4.1.22764.1.1.2.2.9.6
True to request a modification of the first and second pilot associated to a band and a channel of a remote PLC equipment.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

plcPilotsInputResult 1.3.6.1.4.1.22764.1.1.2.2.9.7
Result value of the requested pilot values changes.
Status: current Access: read-only
OBJECT-TYPE    
  ResultValue  

plcNodeNotches 1.3.6.1.4.1.22764.1.1.2.3.1
The values of the notches for all the node bands. The expected format is VALUE VALUE VALUE ... VALUE. Each value is an octet representing the 8 notches of each group. There is one value for each 7 * 16 bands.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

plcNodeNotchesTable 1.3.6.1.4.1.22764.1.1.2.3.2
This table contains Notches configuration for the SPC200 chip.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PlcNodeNotchesEntry

plcNodeNotchesEntry 1.3.6.1.4.1.22764.1.1.2.3.2.1
This row contains Notches configuration for a group. The group is defined by the couple (plcNodeNotchesGroupIndex, plcNodeNotchesBandIndex).
Status: current Access: not-accessible
OBJECT-TYPE    
  PlcNodeNotchesEntry  

plcNodeNotchesBandIndex 1.3.6.1.4.1.22764.1.1.2.3.2.1.1
The band number on which the notches are defined.
Status: current Access: not-accessible
OBJECT-TYPE    
  BandValue  

plcNodeNotchesGroupIndex 1.3.6.1.4.1.22764.1.1.2.3.2.1.2
The group number on which the notches are defined.
Status: current Access: not-accessible
OBJECT-TYPE    
  GroupValue  

plcNodeNotchesCarrier1 1.3.6.1.4.1.22764.1.1.2.3.2.1.3
Tell if the first carrier of the group entry of the band entry is a notch carrier. The true value means the current carrier is a notch.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

plcNodeNotchesCarrier2 1.3.6.1.4.1.22764.1.1.2.3.2.1.4
Tell if the second carrier of the group entry of the band entry is a notch carrier. The true value means the current carrier is a notch.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

plcNodeNotchesCarrier3 1.3.6.1.4.1.22764.1.1.2.3.2.1.5
Tell if the third carrier of the group entry of the band entry is a notch carrier. The true value means the current carrier is a notch.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

plcNodeNotchesCarrier4 1.3.6.1.4.1.22764.1.1.2.3.2.1.6
Tell if the fourth carrier of the group entry of the band entry is a notch carrier. The true value means the current carrier is a notch.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

plcNodeNotchesCarrier5 1.3.6.1.4.1.22764.1.1.2.3.2.1.7
Tell if the fifth carrier of the group entry of the band entry is a notch carrier. The true value means the current carrier is a notch.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

plcNodeNotchesCarrier6 1.3.6.1.4.1.22764.1.1.2.3.2.1.8
Tell if the sixth carrier of the group entry of the band entry is a notch carrier. The true value means the current carrier is a notch.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

plcNodeNotchesCarrier7 1.3.6.1.4.1.22764.1.1.2.3.2.1.9
Tell if the seventh carrier of the group entry of the band entry is a notch carrier. The true value means the current carrier is a notch.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

plcNodeNotchesCarrier8 1.3.6.1.4.1.22764.1.1.2.3.2.1.10
Tell if the eighth carrier of the group entry of the band entry is a notch carrier. The true value means the current carrier is a notch.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

plcNodeNotchesInput 1.3.6.1.4.1.22764.1.1.2.3.3
OBJECT IDENTIFIER    

plcNodeNotchesInputBand 1.3.6.1.4.1.22764.1.1.2.3.3.1
The band number on which the notches value changes are requested.
Status: current Access: read-write
OBJECT-TYPE    
  BandValue  

plcNodeNotchesInputGroup 1.3.6.1.4.1.22764.1.1.2.3.3.2
The group number on which the notches value changes are requested.
Status: current Access: read-write
OBJECT-TYPE    
  GroupValue  

plcNodeNotchesInputCarrier1 1.3.6.1.4.1.22764.1.1.2.3.3.3
The first carrier of the considered group and band is a notch carrier. The true value means the current carrier is a notch.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

plcNodeNotchesInputCarrier2 1.3.6.1.4.1.22764.1.1.2.3.3.4
The second carrier of the considered group and band is a notch carrier. The true value means the current carrier is a notch.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

plcNodeNotchesInputCarrier3 1.3.6.1.4.1.22764.1.1.2.3.3.5
The third carrier of the considered group and band is a notch carrier. The true value means the current carrier is a notch.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

plcNodeNotchesInputCarrier4 1.3.6.1.4.1.22764.1.1.2.3.3.6
The fourth carrier of the considered group and band is a notch carrier. The true value means the current carrier is a notch.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

plcNodeNotchesInputCarrier5 1.3.6.1.4.1.22764.1.1.2.3.3.7
The eighth carrier of the considered group and band is a notch carrier. The true value means the current carrier is a notch.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

plcNodeNotchesInputCarrier6 1.3.6.1.4.1.22764.1.1.2.3.3.8
The eighth carrier of the considered group and band is a notch carrier. The true value means the current carrier is a notch.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

plcNodeNotchesInputCarrier7 1.3.6.1.4.1.22764.1.1.2.3.3.9
The seventh carrier of the considered group and band is a notch carrier. The true value means the current carrier is a notch.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

plcNodeNotchesInputCarrier8 1.3.6.1.4.1.22764.1.1.2.3.3.10
The eighth carrier of the considered group and band is a notch carrier. The true value means the current carrier is a notch.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

plcNodeNotchesInputProceed 1.3.6.1.4.1.22764.1.1.2.3.3.11
True to request a modification of the carrier notches associated to the considered group and band.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

plcNodeNotchesInputResult 1.3.6.1.4.1.22764.1.1.2.3.3.12
Result value of the requested node carrier notches value changes.
Status: current Access: read-only
OBJECT-TYPE    
  ResultValue  

plcNodePilots 1.3.6.1.4.1.22764.1.1.2.3.4
The values of the pilot for all the node bands. The expected format is VALUE VALUE VALUE ... VALUE. Each value is a pair of octets representing the pilot values. There is one pair (pilot1 pilot2) for each of the 7 bands.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

plcNodePilotsTable 1.3.6.1.4.1.22764.1.1.2.3.5
This table contains pilot values used by default on all channels.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PlcNodePilotsEntry

plcNodePilotsEntry 1.3.6.1.4.1.22764.1.1.2.3.5.1
This row contains pilot values used by default on a band. The band is defined by the index plcNodePilotsBandIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  PlcNodePilotsEntry  

plcNodePilotsBandIndex 1.3.6.1.4.1.22764.1.1.2.3.5.1.1
The band number on which the pilot values are defined.
Status: current Access: not-accessible
OBJECT-TYPE    
  BandValue  

plcNodePilot1 1.3.6.1.4.1.22764.1.1.2.3.5.1.2
The default carrier wave number which supports the first pilot wave.
Status: current Access: read-only
OBJECT-TYPE    
  PilotValue  

plcNodePilot2 1.3.6.1.4.1.22764.1.1.2.3.5.1.3
The default carrier wave number which supports the second pilot wave.
Status: current Access: read-only
OBJECT-TYPE    
  PilotValue  

plcNodePilotsInput 1.3.6.1.4.1.22764.1.1.2.3.6
OBJECT IDENTIFIER    

plcNodePilotsInputBand 1.3.6.1.4.1.22764.1.1.2.3.6.1
The band number on which the pilot values changes are requested.
Status: current Access: read-write
OBJECT-TYPE    
  BandValue  

plcInputNodePilot1 1.3.6.1.4.1.22764.1.1.2.3.6.2
The default carrier wave number which supports the first pilot wave of the considered band.
Status: current Access: read-write
OBJECT-TYPE    
  PilotValue  

plcInputNodePilot2 1.3.6.1.4.1.22764.1.1.2.3.6.3
The default carrier wave number which supports the second pilot wave of the considered band.
Status: current Access: read-write
OBJECT-TYPE    
  PilotValue  

plcNodePilotsInputProceed 1.3.6.1.4.1.22764.1.1.2.3.6.4
True to request a modification of the pilot values associated to the considered band.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

plcNodePilotsInputResult 1.3.6.1.4.1.22764.1.1.2.3.6.5
Result value of the requested node pilot values changes.
Status: current Access: read-only
OBJECT-TYPE    
  ResultValue  

plcNodeAdaptsStringTable 1.3.6.1.4.1.22764.1.1.2.3.7
This table contains string values for a quick access to the adapt configurations of all the carriers.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PlcNodeAdaptsStringEntry

plcNodeAdaptsStringEntry 1.3.6.1.4.1.22764.1.1.2.3.7.1
This row contains string values for a quick access to the adapt configuration of each carrier of a band.
Status: current Access: not-accessible
OBJECT-TYPE    
  PlcNodeAdaptsStringEntry  

plcNodeAdaptsStringBandIndex 1.3.6.1.4.1.22764.1.1.2.3.7.1.1
The band number on which the adapt values are defined.
Status: current Access: not-accessible
OBJECT-TYPE    
  BandValue  

plcNodeAdaptsStringBand 1.3.6.1.4.1.22764.1.1.2.3.7.1.2
The adapt values of the 128 carriers of a band. The expected format is VALUE VALUE VALUE ... VALUE. Each value is two octets representing one adapt carrier level. There are ( 16 groups * 8 carriers) = 128 values.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

plcNodeAdaptsTable 1.3.6.1.4.1.22764.1.1.2.3.8
This table contains adapt level configuration for each carrier of the node.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PlcNodeAdaptsEntry

plcNodeAdaptsEntry 1.3.6.1.4.1.22764.1.1.2.3.8.1
This row contains adapt level values for a group of carriers. The group is defined by the couple (plcNodeAdaptsBandIndex,plcNodeAdaptsGroupIndex).
Status: current Access: not-accessible
OBJECT-TYPE    
  PlcNodeAdaptsEntry  

plcNodeAdaptsBandIndex 1.3.6.1.4.1.22764.1.1.2.3.8.1.1
The band number on which the adapt values are defined.
Status: current Access: not-accessible
OBJECT-TYPE    
  BandValue  

plcNodeAdaptsGroupIndex 1.3.6.1.4.1.22764.1.1.2.3.8.1.2
The group number on which the adapt values are defined.
Status: current Access: not-accessible
OBJECT-TYPE    
  GroupValue  

plcNodeAdaptsCarrier1 1.3.6.1.4.1.22764.1.1.2.3.8.1.3
The adapt level of the first carrier of the group.
Status: current Access: read-only
OBJECT-TYPE    
  AdaptValue  

plcNodeAdaptsCarrier2 1.3.6.1.4.1.22764.1.1.2.3.8.1.4
The adapt level of the second carrier of the group.
Status: current Access: read-only
OBJECT-TYPE    
  AdaptValue  

plcNodeAdaptsCarrier3 1.3.6.1.4.1.22764.1.1.2.3.8.1.5
The adapt level of the third carrier of the group.
Status: current Access: read-only
OBJECT-TYPE    
  AdaptValue  

plcNodeAdaptsCarrier4 1.3.6.1.4.1.22764.1.1.2.3.8.1.6
The adapt level of the fourth carrier of the group.
Status: current Access: read-only
OBJECT-TYPE    
  AdaptValue  

plcNodeAdaptsCarrier5 1.3.6.1.4.1.22764.1.1.2.3.8.1.7
The adapt level of the fifth carrier of the group.
Status: current Access: read-only
OBJECT-TYPE    
  AdaptValue  

plcNodeAdaptsCarrier6 1.3.6.1.4.1.22764.1.1.2.3.8.1.8
The adapt level of the sixth carrier of the group.
Status: current Access: read-only
OBJECT-TYPE    
  AdaptValue  

plcNodeAdaptsCarrier7 1.3.6.1.4.1.22764.1.1.2.3.8.1.9
The adapt level of the seventh carrier of the group.
Status: current Access: read-only
OBJECT-TYPE    
  AdaptValue  

plcNodeAdaptsCarrier8 1.3.6.1.4.1.22764.1.1.2.3.8.1.10
The adapt level of the eighth carrier of the group.
Status: current Access: read-only
OBJECT-TYPE    
  AdaptValue  

plcNodeAdaptsInput 1.3.6.1.4.1.22764.1.1.2.3.9
OBJECT IDENTIFIER    

plcNodeAdaptsInputBand 1.3.6.1.4.1.22764.1.1.2.3.9.1
The band number on which the adapt level value changes are requested.
Status: current Access: read-write
OBJECT-TYPE    
  BandValue  

plcNodeAdaptsInputGroup 1.3.6.1.4.1.22764.1.1.2.3.9.2
The group number on which the adapt level value changes are requested.
Status: current Access: read-write
OBJECT-TYPE    
  GroupValue  

plcNodeAdaptsInputCarrier1 1.3.6.1.4.1.22764.1.1.2.3.9.3
The adapt level of the first carrier of the considered group of the chosen band.
Status: current Access: read-write
OBJECT-TYPE    
  AdaptValue  

plcNodeAdaptsInputCarrier2 1.3.6.1.4.1.22764.1.1.2.3.9.4
The adapt level of the second carrier of the considered group of the chosen band.
Status: current Access: read-write
OBJECT-TYPE    
  AdaptValue  

plcNodeAdaptsInputCarrier3 1.3.6.1.4.1.22764.1.1.2.3.9.5
The adapt level of the third carrier of the considered group of the chosen band.
Status: current Access: read-write
OBJECT-TYPE    
  AdaptValue  

plcNodeAdaptsInputCarrier4 1.3.6.1.4.1.22764.1.1.2.3.9.6
The adapt level of the fourth carrier of the considered group of the chosen band.
Status: current Access: read-write
OBJECT-TYPE    
  AdaptValue  

plcNodeAdaptsInputCarrier5 1.3.6.1.4.1.22764.1.1.2.3.9.7
The adapt level of the fifth carrier of the considered group of the chosen band.
Status: current Access: read-write
OBJECT-TYPE    
  AdaptValue  

plcNodeAdaptsInputCarrier6 1.3.6.1.4.1.22764.1.1.2.3.9.8
The adapt level of the sixth carrier of the considered group of the chosen band.
Status: current Access: read-write
OBJECT-TYPE    
  AdaptValue  

plcNodeAdaptsInputCarrier7 1.3.6.1.4.1.22764.1.1.2.3.9.9
The adapt level of the seventh carrier of the considered group of the chosen band.
Status: current Access: read-write
OBJECT-TYPE    
  AdaptValue  

plcNodeAdaptsInputCarrier8 1.3.6.1.4.1.22764.1.1.2.3.9.10
The adapt level of the eighth carrier of the considered group of the chosen band.
Status: current Access: read-write
OBJECT-TYPE    
  AdaptValue  

plcNodeAdaptsInputProceed 1.3.6.1.4.1.22764.1.1.2.3.9.11
True to request a modification of the carrier adapt level associated to the considered group and band.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

plcNodeAdaptsInputResult 1.3.6.1.4.1.22764.1.1.2.3.9.12
Result value of the requested node adapt level value changes.
Status: current Access: read-only
OBJECT-TYPE    
  ResultValue  

plcNodeNetConfigTable 1.3.6.1.4.1.22764.1.1.2.3.10
This table contains ip and mac addresses of the node.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PlcNodeNetConfigEntry

plcNodeNetConfigEntry 1.3.6.1.4.1.22764.1.1.2.3.10.1
This row contains ip and mac address used by an interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  PlcNodeNetConfigEntry  

plcNodeIpAddr 1.3.6.1.4.1.22764.1.1.2.3.10.1.1
The IP address of the IP layer above the interface.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

plcNodeNetMask 1.3.6.1.4.1.22764.1.1.2.3.10.1.2
The IP Subnet mask of the IP layer above the interface.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

plcNodeMacAddr 1.3.6.1.4.1.22764.1.1.2.3.10.1.3
The MAC address of the MAC layer above the interface.
Status: current Access: read-write
OBJECT-TYPE    
  MacAddress  

plcNodeGateway 1.3.6.1.4.1.22764.1.1.2.3.10.1.4
The Gateway address of the IP layer above the interface.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

plcNodeActions 1.3.6.1.4.1.22764.1.1.2.3.11
OBJECT IDENTIFIER    

plcNodeActionsCommit 1.3.6.1.4.1.22764.1.1.2.3.11.1
OBJECT IDENTIFIER    

plcNodeActionsCommitProceed 1.3.6.1.4.1.22764.1.1.2.3.11.1.1
True to request the commit of the configuration changes into the flash memory
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

plcNodeActionsCommitResult 1.3.6.1.4.1.22764.1.1.2.3.11.1.2
Result value of the requested flash commit operation.
Status: current Access: read-only
OBJECT-TYPE    
  ResultValue  

plcNodeActionsReset 1.3.6.1.4.1.22764.1.1.2.3.11.2
OBJECT IDENTIFIER    

plcNodeActionsResetProceed 1.3.6.1.4.1.22764.1.1.2.3.11.2.1
True to request the reset of the node. This operation will terminate the communication between the manager and the node
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

plcNodeActionsCarrier 1.3.6.1.4.1.22764.1.1.2.3.11.3
OBJECT IDENTIFIER    

plcNodeActionsCarrierFlatProceed 1.3.6.1.4.1.22764.1.1.2.3.11.3.1
True to request the equipment to flat the signal
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

plcBssId 1.3.6.1.4.1.22764.1.1.2.6
OBJECT IDENTIFIER    

plcMasterBssId 1.3.6.1.4.1.22764.1.1.2.6.1
The value of the master Bss Id
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..99  

plcSlaveBssId 1.3.6.1.4.1.22764.1.1.2.6.2
The value of the slave Bss Id
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..99  

plcSpy 1.3.6.1.4.1.22764.1.1.2.7
OBJECT IDENTIFIER    

plcSpyIsDynamic 1.3.6.1.4.1.22764.1.1.2.7.1
True to set the spy dynamic mode
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

plcStaticSpySynchBandNb 1.3.6.1.4.1.22764.1.1.2.7.2
The synchronization band number used for static spy mode
Status: current Access: read-write
OBJECT-TYPE    
  BandValue  

softwareMgnt 1.3.6.1.4.1.22764.1.1.3
OBJECT IDENTIFIER    

currentSoftwareVersion 1.3.6.1.4.1.22764.1.1.3.1
The name of the current software release.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

currentSoftwareBoardVersion 1.3.6.1.4.1.22764.1.1.3.2
The name of the current software board release.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

currentSoftwareAFEVersion 1.3.6.1.4.1.22764.1.1.3.3
The name of the current software Analog Front End release.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

softwareTable 1.3.6.1.4.1.22764.1.1.3.4
This table contains the current and reserve softwares of the node.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SoftwareEntry

softwareEntry 1.3.6.1.4.1.22764.1.1.3.4.1
This row contains software information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SoftwareEntry  

softwareIndex 1.3.6.1.4.1.22764.1.1.3.4.1.1
The index number of the software.
Status: current Access: not-accessible
OBJECT-TYPE    
  SoftwareIndex  

softwareVersion 1.3.6.1.4.1.22764.1.1.3.4.1.2
The name of the software release.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

softwareUpload 1.3.6.1.4.1.22764.1.1.3.5
OBJECT IDENTIFIER    

softwareUploadTFTPServerIP 1.3.6.1.4.1.22764.1.1.3.5.1
The IP address of the TFTP serveur
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

softwareUploadLogin 1.3.6.1.4.1.22764.1.1.3.5.2
The user login on the TFTP server
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..16)  

softwareUploadPassword 1.3.6.1.4.1.22764.1.1.3.5.3
The user password on the TFTP server. Warning: This field is displayed using 6 * characters
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..16)  

softwareUploadFileName 1.3.6.1.4.1.22764.1.1.3.5.4
The software file name to upload
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

softwareUploadProceed 1.3.6.1.4.1.22764.1.1.3.5.5
True to request the uploading to start
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

softwareUploadResult 1.3.6.1.4.1.22764.1.1.3.5.6
Result value of the requested uploading
Status: current Access: read-only
OBJECT-TYPE    
  SoftwareActionResultValue  

softwareUploadTFTPServerPort 1.3.6.1.4.1.22764.1.1.3.5.7
The service port of the TFTP server
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

softwareAction 1.3.6.1.4.1.22764.1.1.3.6
OBJECT IDENTIFIER    

softwareActionIndex 1.3.6.1.4.1.22764.1.1.3.6.1
The index of the reserve software
Status: current Access: read-write
OBJECT-TYPE    
  SoftwareIndex  

softwareActionType 1.3.6.1.4.1.22764.1.1.3.6.2
Type of the software action software: switch, remove
Status: current Access: read-write
OBJECT-TYPE    
  SoftwareActionType  

softwareActionProceed 1.3.6.1.4.1.22764.1.1.3.6.3
True to request the switch between the current and the reserver software to start
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

softwareActionResult 1.3.6.1.4.1.22764.1.1.3.6.4
Result value of the requested action
Status: current Access: read-only
OBJECT-TYPE    
  SoftwareActionResultValue  

plcConformance 1.3.6.1.4.1.22764.1.1.4
OBJECT IDENTIFIER    

plcCompliances 1.3.6.1.4.1.22764.1.1.4.1
OBJECT IDENTIFIER    

plcGroups 1.3.6.1.4.1.22764.1.1.4.2
OBJECT IDENTIFIER    

plcCompliance 1.3.6.1.4.1.22764.1.1.4.1.1
The compliance statement for SPC200 chip.
Status: current Access: read-only
MODULE-COMPLIANCE    

nodeGroup 1.3.6.1.4.1.22764.1.1.4.2.1
A collection of objects providing node configuration information.
Status: current Access: read-only
OBJECT-GROUP    

inputNodeGroup 1.3.6.1.4.1.22764.1.1.4.2.2
A collection of objects used to request node configuration information changes.
Status: current Access: read-only
OBJECT-GROUP    

topologyGroup 1.3.6.1.4.1.22764.1.1.4.2.3
A collection of objects providing topology configuration.
Status: current Access: read-only
OBJECT-GROUP    

inputTopologyGroup 1.3.6.1.4.1.22764.1.1.4.2.4
A collection of objects used to request topology configuration changes.
Status: current Access: read-only
OBJECT-GROUP    

statisticGroup 1.3.6.1.4.1.22764.1.1.4.2.5
A collection of objects providing statistic data on node and plc link performances.
Status: current Access: read-only
OBJECT-GROUP    

softwareGroup 1.3.6.1.4.1.22764.1.1.4.2.6
A collection of objects providing software management
Status: current Access: read-only
OBJECT-GROUP    

analyserGroup 1.3.6.1.4.1.22764.1.1.4.2.7
A collection of objects providing spectrum analyser data
Status: current Access: read-only
OBJECT-GROUP    

agentCapabilities 1.3.6.1.4.1.22764.1.1.4.3
The SPC200 chip SNMP agent capabilities
Status: current Access: not-implemented
AGENT-CAPABILITIES    

ipExt 1.3.6.1.4.1.22764.1.4
Extended ip needed for SPiDCOM functionalities
Status: current Access: not-implemented
OBJECT-IDENTITY    

ipDynamic 1.3.6.1.4.1.22764.1.4.1
True if Ip address is set dynamically
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

ipExtGroup 1.3.6.1.4.1.22764.1.4.2
The fields needed by the SPiDCOM functionalities
Status: current Access: read-write
OBJECT-GROUP