SLE-MPLS-TP-NODE-MIB

File: SLE-MPLS-TP-NODE-MIB.mib (7917 bytes)

Imported modules

DASAN-SMI MPLS-TC-EXT-STD-MIB MPLS-TE-STD-MIB
SLE-TC-MIB SNMPv2-SMI

Imported symbols

sleMgmt MplsCcId MplsIccId
mplsTunnelIndex mplsTunnelInstance mplsTunnelIngressLSRId
mplsTunnelEgressLSRId SleControlStatusType SleControlRequestResultType
zeroDotZero TimeTicks IpAddress
Unsigned32 Gauge32 OBJECT-TYPE
MODULE-IDENTITY OBJECT-IDENTITY

Defined Values

sleMplsTpNode 1.3.6.1.4.1.6296.101.16.13
Copyright (c) 2012 IETF Trust and the persons identified as the document authors. All rights reserved. This MIB module contains generic object definitions for MPLS Traffic Engineering in transport networks.
MODULE-IDENTITY    

sleMpls 1.3.6.1.4.1.6296.101.16
SLE MPLS.
Status: current Access: read-write
OBJECT-IDENTITY    

sleMplsTpNodeCfg 1.3.6.1.4.1.6296.101.16.13.1
OBJECT IDENTIFIER    

sleMplsTpNodeCfgInfo 1.3.6.1.4.1.6296.101.16.13.1.1
OBJECT IDENTIFIER    

sleMplsTpNodeCfgInfoGlobalId 1.3.6.1.4.1.6296.101.16.13.1.1.1
This object indicates the Global Operator Identifier. this object value should be zero when sleMplsTpNodeConfigInfoCcId and sleMplsTpNodeConfigInfoICcId is configured with non-null value.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 1..4294967295  

sleMplsTpNodeCfgInfoItutCc 1.3.6.1.4.1.6296.101.16.13.1.1.2
This object allows the operator or service provider to configure a unique MPLS-TP ITU-T Carrier Code (ICC) either for Ingress ID or Egress ID. This object value should be zero when sleMplsTpNodeConfigInfoGlobalId are assigned with non-zero value.
Status: current Access: read-only
OBJECT-TYPE    
  MplsCcId  

sleMplsTpNodeCfgInfoItutIcc 1.3.6.1.4.1.6296.101.16.13.1.1.3
This object allows the operator or service provider to configure a unique MPLS-TP ITU-T Carrier Code (ICC) either for Ingress ID or Egress ID. This object value should be zero when sleMplsTpNodeConfigInfoGlobalId are assigned with non-zero value.
Status: current Access: read-only
OBJECT-TYPE    
  MplsIccId  

sleMplsTpNodeCfgInfoNodeId 1.3.6.1.4.1.6296.101.16.13.1.1.4
This object indicates the Node_ID within the operator.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

sleMplsTpNodeCfgInfoNodeType 1.3.6.1.4.1.6296.101.16.13.1.1.5
This object value should be zero when sleMplsTpNodeConfigInfoGlobalId are assigned with non-zero value .
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ietf(1), itut(2)  

sleMplsTpNodeCfgControl 1.3.6.1.4.1.6296.101.16.13.1.2
OBJECT IDENTIFIER    

sleMplsTpNodeCfgControlRequest 1.3.6.1.4.1.6296.101.16.13.1.2.1
This object holds the possible read-write columns that can be modified in the TunnelExtNodeConfigTable table. For each read-write column of TunnelExtNodeConfigTable table, a Set Operation control value is added in this object.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER setMplsTpNode(1), unsetMplsTpNode(2)  

sleMplsTpNodeCfgControlStatus 1.3.6.1.4.1.6296.101.16.13.1.2.2
This object displays the status of the configuration done.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlStatusType  

sleMplsTpNodeCfgControlTimer 1.3.6.1.4.1.6296.101.16.13.1.2.3
This object is based on the SLE style where a timer is configured for every control table.
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

sleMplsTpNodeCfgControlTimestamp 1.3.6.1.4.1.6296.101.16.13.1.2.4
This object specifies the time at which the configuration is done.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

sleMplsTpNodeCfgControlReqResult 1.3.6.1.4.1.6296.101.16.13.1.2.5
The standard result of the SET operation is stored here.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlRequestResultType  

sleMplsTpNodeCfgControlGlobalId 1.3.6.1.4.1.6296.101.16.13.1.2.6
This object indicates the Global Operator Identifier. This object value should be zero when sleMplsTpNodeConfigControlIccId and sleMplsTpNodeConfigControlccId is configured with non-null value.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 1..4294967295  

sleMplsTpNodeCfgControlItutCc 1.3.6.1.4.1.6296.101.16.13.1.2.7
This object allows the operator or service provider to configure a unique MPLS-TP ITU-T Carrier Code (ICC) either for Ingress ID or Egress ID. This object value should be zero when sleMplsTpNodeConfigControlGlobalId are assigned with non-zero value.
Status: current Access: read-write
OBJECT-TYPE    
  MplsCcId  

sleMplsTpNodeCfgControlItutIcc 1.3.6.1.4.1.6296.101.16.13.1.2.8
This object allows the operator or service provider to configure a unique MPLS-TP ITU-T Carrier Code (ICC) either for Ingress ID or Egress ID. This object value should be zero when sleMplsTpNodeConfigControlGlobalId are assigned with non-zero value.
Status: current Access: read-write
OBJECT-TYPE    
  MplsIccId  

sleMplsTpNodeCfgControlNodeId 1.3.6.1.4.1.6296.101.16.13.1.2.9
This object indicates the Node_ID within the operator.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

sleMplsTpNodeCfgControlNodeType 1.3.6.1.4.1.6296.101.16.13.1.2.10
This object allows the operator or service provider to configure a unique MPLS-TP ITU-T Carrier Code (ICC) either for Ingress ID or Egress ID. This object value should be zero when msleMplsTpNodeConfigControlGlobalId are assigned with non-zero value.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ietf(1), itut(2)