SCTE-HMS-HEADENDIDENT-MIB
File:
SCTE-HMS-HEADENDIDENT-MIB.mib (9120 bytes)
Imported modules
Imported symbols
Defined Types
HeTenthVolt |
|
This data type represents voltage levels that are normally
expressed in volts. Units are in tenths of a volt;
for example, -48.1 volts will be represented as -481. |
TEXTUAL-CONVENTION |
|
|
|
|
Integer32 |
|
|
HeTenthdBm |
|
This data type represents power levels
that are normally expressed in dBm. Units
are in tenths of a dBm;
for example, -5.1 dBm will be represented as -51. |
TEXTUAL-CONVENTION |
|
|
|
|
Integer32 |
|
|
HeTenthdBmV |
|
This data type represents power levels
that are normally expressed in dBmV. Units
are in tenths of a dBmV;
for example, -5.1 dBmV will be represented as -51. |
TEXTUAL-CONVENTION |
|
|
|
|
Integer32 |
|
|
HeTenthCentigrade |
|
This data type represents temperature values that
are normally expressed in Centigrade. Units are in
tenths of a Centigrade;
for example, -5.1 Centigrade will be represented as -51. |
TEXTUAL-CONVENTION |
|
|
|
|
Integer32 |
|
|
HeHundredthNanoMeter |
|
This data type represents wavelength values that
are normally expressed in nano meters. Units are in
hundredths of a NanoMeter;
for example, 1550.56 nm will be represented as 155056. |
TEXTUAL-CONVENTION |
|
|
|
|
Unsigned32 |
|
|
HeTenthdB |
|
This data type represents power levels
that are normally expressed in dB. Units
are in tenths of a dB;
for example, -5.1 dB will be represented as -51. |
TEXTUAL-CONVENTION |
|
|
|
|
Integer32 |
|
|
HeOnOffControl |
|
An enumerated value that provides a control of a particular
hardware or software parameter that usually represent
some sort of switch.
A SET request with a value off(1) will cause the switch
to be shut off.
A SET request with a value on(2) will cause the switch
to be turned on.
A value meaningless(3) will be implemented by the
variables that represent a switch with write-only access.
A GET request for the value of the write-only variable
shall return a value meaningless(3).
A SET request with a value meaningless(3) for the variable
with write access shall have no effect and no exception is
generated.
A value may be used by the variables with both read-write
and write-only access.
The variables with read-only access shall be defined with
the textual convention HeOnOffStatus. |
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
off(1), on(2), meaningless(3) |
|
HeOnOffStatus |
|
An enumerated value that provides a status of a particular
hardware or software parameter that usually represent
some sort of switch.
A value off(1) indicates the switch is off.
A value on(2) indicates the switch is on. |
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
off(1), on(2) |
|
HeFaultStatus |
|
An enumerated value that provides a fault status of
a particular hardware or software parameter that
usually represent some sort of condition.
A value normal(1) indicates the normal condition.
A value fault(2) indicates the fault condition. |
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
normal(1), fault(2) |
|
HeLaserType |
|
Laser type. Some example values are: unisolated FP,
isolated FP, uncooled DFB, cooled DFB, ITU (up to
32 colors). |
TEXTUAL-CONVENTION |
|
|
|
|
DisplayString |
|
|
HeMilliAmp |
|
This data type represents current levels that are normally
expressed in amperes. Units are in milliamperes;
for example, 2.1 Amperes would be expressed as 2100. |
TEXTUAL-CONVENTION |
|
|
|
|
Unsigned32 |
|
|
HeHundredthWatts |
|
This data type represents power values that
are normally expressed in watts. Units are in
hundredths of a watt;
for example, 420 watts will be represented as 42000. |
TEXTUAL-CONVENTION |
|
|
|
|
Unsigned32 |
|
|
Defined Values
headEndIdentMib |
1.3.6.1.4.1.5591.1.11.0 |
The MIB module is for representing optical equipment
present in the headend (or indoor) and is supported by
a SNMP agent. This module defines the root OID (under
the scteHmsTree) for the indoor optic device MIBs such
as Optical transmitters, receivers, amplifiers etc.
This module also defines textual conventions that are
common across indoor devices. |
MODULE-IDENTITY |
|
|
|
heOptics |
1.3.6.1.4.1.5591.1.11.1 |
Defines the base OID for the inside plant optical equipment
(see SCTE 83-1, formerly HMS108) including, but not limited to,
optical transmitters (see SCTE 85-1, formerly HMS112),
optical receivers (see SCTE 85-2, formerly HMS113),
optical amplifiers (see SCTE 85-3, formerly HMS118),
optical switches etc. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
heBaseIdent |
1.3.6.1.4.1.5591.1.11.2 |
Defines the base OID for the common part of the inside plant
equipment (see SCTE 84-1; formerly HMS111) including, but not
limited to, power supplies (see SCTE 84-2; formerly HMS116),
fans (see SCTE 84-3; formerly HMS117), etc. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
heCommon |
1.3.6.1.4.1.5591.1.11.2.1 |
Defines the base OID for the modelling of
all indoor equipment(see SCTE 84-1; formerly HMS111). |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
hePowerSupply |
1.3.6.1.4.1.5591.1.11.2.2 |
Defines the base OID for the modelling of
indoor Power Supply(see SCTE 84-2; formerly HMS116). |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
heFans |
1.3.6.1.4.1.5591.1.11.2.3 |
Defines the base OID for the modelling of
indoor Fans (see SCTE 84-3; formerly HMS117). |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
heHMTS |
1.3.6.1.4.1.5591.1.11.3 |
Defines the base of the HMTS (see SCTE 83-3; formerly HMS120). |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
heRF |
1.3.6.1.4.1.5591.1.11.4 |
Defines the base OID for the inside plant RF equipment
(see SCTE 83-4, formerly HMS133) including, but not limited to,
RF amplifiers (see SCTE 94-1, formerly HMS131),
RF switches (see SCTE 94-2, formerly HMS132) etc. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
heDigital |
1.3.6.1.4.1.5591.1.11.5 |
Defines the base OID for the inside plant Digital devices
including QAM, Encoders, Decoders, MPEG, IP etc .... |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
heManagedServer |
1.3.6.1.4.1.5591.1.11.6 |
Defines the base OID for the inside plant Managed Servers.
Servers can be any machine that is used to serve data such
as a video server, a timing server, a resource server ..etc |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|