RBN-SFP-MIB
File:
RBN-SFP-MIB.mib (8662 bytes)
Imported modules
Imported symbols
Defined Types
RbnSfpAlarmActiveEntry |
|
SEQUENCE |
|
|
|
|
rbnSfpActiveAlarmIndex |
Unsigned32 |
|
|
rbnSfpAlarmCardSlot |
RbnSlot |
|
|
rbnSfpAlarmPort |
RbnPort |
|
|
rbnSfpAlarmId |
RbnAlarmId |
|
|
rbnSfpAlarmSeverity |
ItuPerceivedSeverity |
|
|
rbnSfpAlarmType |
IANAItuEventType |
|
|
rbnSfpAlarmDateAndTime |
DateAndTime |
|
|
rbnSfpAlarmDescription |
SnmpAdminString |
|
|
rbnSfpAlarmProbableCause |
IANAItuProbableCause |
|
|
rbnSfpAlarmServiceAffecting |
RbnAlarmServiceAffecting |
|
Defined Values
rbnSfpMonMIB |
1.3.6.1.4.1.2352.2.49 |
The MIB used to manage the SFP (Small Form Factor Pluggable)
devices. |
MODULE-IDENTITY |
|
|
|
rbnSfpAlarmActiveEntry |
1.3.6.1.4.1.2352.2.49.1.1.1 |
Entries appear in this table when alarms are
raised. They are removed when the alarms are cleared. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
RbnSfpAlarmActiveEntry |
|
|
rbnSfpActiveAlarmIndex |
1.3.6.1.4.1.2352.2.49.1.1.1.1 |
A monotonically increasing integer index. It wraps
back to 1 after it reaches its maximum value. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..4294967295 |
|
rbnSfpAlarmCardSlot |
1.3.6.1.4.1.2352.2.49.1.1.1.2 |
The chassis slot number in which the card is present where the SFP plugged in. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
RbnSlot |
|
|
rbnSfpAlarmPort |
1.3.6.1.4.1.2352.2.49.1.1.1.3 |
The port number where the SFP plugged in. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
RbnPort |
|
|
rbnSfpAlarmId |
1.3.6.1.4.1.2352.2.49.1.1.1.4 |
An identifier for the alarm. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
RbnAlarmId |
|
|
rbnSfpAlarmDescription |
1.3.6.1.4.1.2352.2.49.1.1.1.8 |
A text string which conveys additional information
about the alarm. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
SnmpAdminString |
Size(0..64) |
|
rbnSfpAlarm |
1.3.6.1.4.1.2352.2.49.0.1 |
An rbnSfpAlarm notification signifies that an
alarm has been raised or cleared on a SFP |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
rbnSfpMonMIBObjectGroup |
1.3.6.1.4.1.2352.2.49.2.1.1 |
A collection of objects providing active SFP Alarm information |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
rbnSfpMonMIBNotificationGroup |
1.3.6.1.4.1.2352.2.49.2.1.2 |
A collection of notifications providing SFP fault condition |
Status: current |
Access: read-only |
NOTIFICATION-GROUP |
|
|
|
rbnSfpMonMIBCompliance |
1.3.6.1.4.1.2352.2.49.2.2.1 |
The compliance statement for the Sfp active alarm MIB |
Status: current |
Access: read-only |
MODULE-COMPLIANCE |
|
|
|