PT-RADIOLINK-MIB

File: PT-RADIOLINK-MIB.mib (51428 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
INET-ADDRESS-MIB IF-MIB PT-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Counter32
Integer32 IpAddress TEXTUAL-CONVENTION
MODULE-COMPLIANCE OBJECT-GROUP InetAddressIPv6
ifEntry pt

Defined Types

AcmTC  
An integer which indicates the ACM.
TEXTUAL-CONVENTION    
  INTEGER acmHalfBpsk(1), acmHalfBpskLight(2), acmHalfBpskStrong(3), acmBpsk(4), acmBpskLight(5), acmBpskStrong(6), acm4Qam(7), acm4QamLight(8), acm4QamStrong(9), acm16Qam(10), acm16QamLight(11), acm16QamStrong(12), acm32Qam(13), acm32QamLight(14), acm32QamStrong(15), acm64Qam(16), acm64QamLight(17), acm64QamStrong(18), acm128Qam(19), acm128QamLight(20), acm128QamStrong(21), acm256Qam(22), acm256QamLight(23), acm256QamStrong(24), acm512Qam(25), acm512QamLight(26), acm512QamStrong(27), acm1024Qam(28), acm1024QamLight(29), acm1024QamStrong(30), acm2048Qam(31), acm2048QamLight(32), acm2048QamStrong(33), acm4096Qam(34), acm4096QamLight(35), acm4096QamStrong(36)  

EnableStatusTC  
An integer which indicates the enabled status.
TEXTUAL-CONVENTION    
  INTEGER enabled(1), disabled(2), unknown(3)  

XpicMimoTC  
An integer which indicates the XPIC or MIMO status.
TEXTUAL-CONVENTION    
  INTEGER notAvailable(1), locked(2), unlocked(3), unknown(4)  

CtEntry  
SEQUENCE    
  actualInputPower OCTET STRING
  actualOutputPower OCTET STRING
  actualRxAcm OCTET STRING
  actualTxAcm OCTET STRING
  ctDistinguishedName OCTET STRING
  description OCTET STRING
  carrierId INTEGER
  ctStatus INTEGER
  frameId Integer32
  txFrequency Integer32
  minTxFrequency Integer32
  maxTxFrequency Integer32
  rxFrequency Integer32
  minRxFrequency Integer32
  maxRxFrequency Integer32
  frequencyStepSize Integer32
  duplexDistance Integer32
  duplexType INTEGER
  duplexConfig EnableStatusTC
  autoFreqSelection INTEGER
  autoFreqSelectedChannel Integer32
  autoFreqSelectionStatus INTEGER
  channelSpacing INTEGER
  polarization INTEGER
  txOperStatus INTEGER
  txAdminStatus INTEGER
  selectedOutputPowerType INTEGER
  availableOutputPowerType INTEGER
  selectedMinOutputPower Integer32
  selectedMaxOutputPower Integer32
  availableMinOutputPower Integer32
  availableMaxOutputPower Integer32
  referenceSec INTEGER
  targetInputPowerFarEnd Integer32
  berAlarmThreshold INTEGER
  inputPowerAlarmThreshold Integer32
  plannedAlignmentInputPower Integer32
  atpcFallback EnableStatusTC
  atpcFallbackTimer Integer32
  atpcFallbackOutputPower Integer32
  xpicStatus XpicMimoTC
  mimoStatus XpicMimoTC
  actualSnir OCTET STRING
  actualXpi OCTET STRING
  actualSi OCTET STRING
  actualTxCapacity Integer32
  licensedCapacity Integer32
  availableMinCapacity Integer32
  availableMaxCapacity Integer32
  selectedMinCapacity Integer32
  selectedMaxCapacity Integer32
  wantedLicensedCapacity Integer32
  availableMinAcm AcmTC
  availableMaxAcm AcmTC
  selectedMinAcm AcmTC
  selectedMaxAcm AcmTC
  actualRxAcmTC AcmTC
  actualTxAcmTC AcmTC
  alignmentMode EnableStatusTC
  rfLoop EnableStatusTC

RltEntry  
SEQUENCE    
  rltDistinguishedName OCTET STRING
  neIpAddress IpAddress
  neIpv6Address InetAddressIPv6
  neName OCTET STRING
  neType INTEGER
  id OCTET STRING
  rltStatus INTEGER
  mode INTEGER
  actualTxTotalCapacity Integer32
  limitedTotalCapacity Integer32
  protectionStatus INTEGER
  revertiveWaitToRestore Integer32
  revertivePreferredTx INTEGER
  protectionSwitchMode INTEGER
  fadeNotificationTimer Integer32
  expectedFarEndId OCTET STRING
  farEndIdCheck INTEGER
  cpriMode INTEGER
  cpriStatus INTEGER
  manualSwitch INTEGER
  mlhcOperStatus INTEGER
  mlhcAdminStatus INTEGER
  mlhcMplsConfig INTEGER
  plcOperStatus INTEGER
  plcAdminStatus INTEGER

CtG826ContinuousEntry  
SEQUENCE    
  ctG826TimeElapsed Counter32
  ctBBE Counter32
  ctBBER OCTET STRING
  ctES Counter32
  ctESR OCTET STRING
  ctSES Counter32
  ctSESR OCTET STRING
  ctBB OCTET STRING
  ctUAS Counter32
  ctG826Reset INTEGER

CtG826Current15mEntry  
SEQUENCE    
  ctG826Current15mTimeElapsed Counter32
  ctCurrent15mBBE Counter32
  ctCurrent15mBBER OCTET STRING
  ctCurrent15mES Counter32
  ctCurrent15mESR OCTET STRING
  ctCurrent15mSES Counter32
  ctCurrent15mSESR OCTET STRING
  ctCurrent15mBB Counter32
  ctCurrent15mUAS Counter32

CtG826Current24hEntry  
SEQUENCE    
  ctG826Current24hTimeElapsed Counter32
  ctCurrent24hBBE Counter32
  ctCurrent24hBBER OCTET STRING
  ctCurrent24hES Counter32
  ctCurrent24hESR OCTET STRING
  ctCurrent24hSES Counter32
  ctCurrent24hSESR OCTET STRING
  ctCurrent24hBB Counter32
  ctCurrent24hUAS Counter32

Defined Values


ptRadioLinkConformance 6.7.2
OBJECT IDENTIFIER    

ctPerformance 6.7.4
OBJECT IDENTIFIER    

ctTable 6.7.1
A table of CT Table entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CtEntry

ctEntry 6.7.1.1
An entry of CT application.
Status: current Access: not-accessible
OBJECT-TYPE    
  CtEntry  

actualInputPower 6.7.1.1.1
Actual input power of the CT in dBm
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

actualOutputPower 6.7.1.1.2
Actual output power of the CT in dBm
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

actualRxAcm 6.7.1.1.3
Actual rx modulation and coding
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

actualTxAcm 6.7.1.1.4
Actual tx modulation and coding
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

ctDistinguishedName 6.7.1.1.5
Unique id/name of the carrier termination, according to FDN (rack/slot/port/class)
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

description 6.7.1.1.6
User description of the carrior termination.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

carrierId 6.7.1.1.7
Id of the carrier. (A, B, C, D) Used in XPIC & MIMO configurations to check that the carrier termination is connected to the correct far end carrier termination. Should be the same id on both sides of the hop. Defaulted when not MIMO or XPIC. Sometimes also referred to as preamble
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER a(1), b(2), c(3), d(4), unknown(5)  

ctStatus 6.7.1.1.8
The status of the carrier termination, hop
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER down(1), up(2), na(3), unknown(4), degraded(5)  

frameId 6.7.1.1.9
A unique identifier for the radio frame to be used. Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..10000  

txFrequency 6.7.1.1.10
Selected frequency on the transmitter (kHz). Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

minTxFrequency 6.7.1.1.11
Minimum Tx frequency possible to use, given by the selected frame-id
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

maxTxFrequency 6.7.1.1.12
Maximum Tx frequency possible to use, given by the selected frame-id
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rxFrequency 6.7.1.1.13
Selected frequency on the receiver (kHz). Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

minRxFrequency 6.7.1.1.14
Minimum Rx frequency possible to use, given by the selected frame-id
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

maxRxFrequency 6.7.1.1.15
Maximum Rx frequency possible to use, given by the selected frame-id
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frequencyStepSize 6.7.1.1.16
Frequency step size in kHz
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

duplexDistance 6.7.1.1.17
Distance between Tx and Rx frequencies (kHz)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

duplexType 6.7.1.1.18
The duplex type is given by the equipment (Fixed,Variable)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER variable(1), fixed(2), unknown(3)  

duplexConfig 6.7.1.1.19
Enabling or disabling configuration of Rx freq using duplex distance
Status: current Access: read-write
OBJECT-TYPE    
  EnableStatusTC  

autoFreqSelection 6.7.1.1.20
Automatic frequency selection mode
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), master(2), slave(3), unknown(4)  

autoFreqSelectedChannel 6.7.1.1.21
Automatic frequency selected channel
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

autoFreqSelectionStatus 6.7.1.1.22
Automatic frequency status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER idle(1), searchingForSlave(2), requestingInfoFromSlave(3), waitingForMaster(4), waitingForChannelInfoRequest(5), inProgress(6), initializing(7), finished(8), failed(9), unknown(10)  

channelSpacing 6.7.1.1.23
Channel spacing
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER cs7MHz(1), cs10MHz(2), cs14MHz(3), cs20MHz(4), cs28MHz(5), cs30MHz(6), cs40MHz(7), cs50MHz(8), cs56MHz(9), cs250MHz(10), cs60MHz(11), cs500MHz(12), cs750MHz(13), cs100MHz(14), cs150MHz(15), cs200MHz(16), cs125MHz(17), cs80MHz(18), cs112MHz(19), cs1000MHz(20), cs1250MHz(21), cs1500MHz(22), cs62p5MHz(23), cs2000MHz(24), unknown(25)  

polarization 6.7.1.1.24
Antenna polarization
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notSpecified(1), horizontal(2), vertical(3), unknown(4)  

txOperStatus 6.7.1.1.25
Operative status of the transmitter
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), off(2), on(3), standby(4)  

txAdminStatus 6.7.1.1.26
Administrative status of the transmitter
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2), unknown(3)  

selectedOutputPowerType 6.7.1.1.27
Selected output power type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER standard(1), high(2), unknown(3)  

availableOutputPowerType 6.7.1.1.28
Available output power type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER standard(1), high(2), unknown(3)  

selectedMinOutputPower 6.7.1.1.29
Selected min output power. Selected min & max output power should be set to the same value for RTPC mode, otherwise the hop operates in ATPC mode.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

selectedMaxOutputPower 6.7.1.1.30
Selected max output power. Selected min & max output power should be set to the same value for RTPC mode, otherwise the hop operates in ATPC mode.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

availableMinOutputPower 6.7.1.1.31
The minimum output power supported (dBm). The system shows a value if the equipment is available and a frame id has been selected.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

availableMaxOutputPower 6.7.1.1.32
The maximum output power supported (dBm). The system shows a value if the equipment is available and a frame id has been selected.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

referenceSec 6.7.1.1.33
Each modulation is compliant to a Reference Spectrum Efficiency Class (RSEC). When running Adaptive Coding/Modulation, one SEC has to be selected for all the coding/modulations between selectedMinACM and selectedMaxACM. This parameter is called Reference SEC. This setting will affect availableMaxOutputPower, in order to fulfill spectrum requirements. Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noAvailable(1), sec2(2), sec4L(4), sec4H(5), sec5B(7), sec6B(9), sec5LB(10), sec5HB(11), sec6LB(12), sec6HB(13), sec7B(14), unknown(15)  

targetInputPowerFarEnd 6.7.1.1.34
The wanted input power at far end (dBm), when running ATPC
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

berAlarmThreshold 6.7.1.1.35
Threshold for the BER alarm
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER tenExpMinus6(1), tenExpMinus3(2)  

inputPowerAlarmThreshold 6.7.1.1.36
Threshold for the input power alarm
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

plannedAlignmentInputPower 6.7.1.1.37
The planned received input power (dBm) dependent upon selected minimum ACM and corresponding output power. Used when doing alignment
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atpcFallback 6.7.1.1.38
Enable or disable the output power fall back function
Status: current Access: read-write
OBJECT-TYPE    
  EnableStatusTC  

atpcFallbackTimer 6.7.1.1.39
Specifies the timer for output power fall back (# of seconds)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atpcFallbackOutputPower 6.7.1.1.40
The ATPC fallback output power
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

xpicStatus 6.7.1.1.41
Status of the XPIC function.
Status: current Access: read-only
OBJECT-TYPE    
  XpicMimoTC  

mimoStatus 6.7.1.1.42
Status of the MIMO function.
Status: current Access: read-only
OBJECT-TYPE    
  XpicMimoTC  

actualSnir 6.7.1.1.43
Actual signal to noise plus interference ratio (dB).
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

actualXpi 6.7.1.1.44
The carrier to cross-polar interference level (dBc).
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

actualSi 6.7.1.1.45
Spatial interference between the CTs when MIMO is configured.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

actualTxCapacity 6.7.1.1.46
Actual capacity supported by the carrier termination.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

licensedCapacity 6.7.1.1.47
Wanted or installed license for the capacity allowed for the carrier termination.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

availableMinCapacity 6.7.1.1.48
Minimum capacity possible to use. Given by the selected frame-id (kbit/s)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

availableMaxCapacity 6.7.1.1.49
Maximum capacity possible to use. Given by the selected frame-id (kbit/s)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

selectedMinCapacity 6.7.1.1.50
Selected minimum capacity, derived from selected minimum ACM (kbit/s)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

selectedMaxCapacity 6.7.1.1.51
Selected maximum capacity, derived from selected maximum ACM (kbit/s)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

wantedLicensedCapacity 6.7.1.1.52
Wanted licensed capacity and creation of LRF for the carrier termination (kbit/s)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

availableMinAcm 6.7.1.1.53
Minimum ACM possible to use, given by the selected frame id.
Status: current Access: read-only
OBJECT-TYPE    
  AcmTC  

availableMaxAcm 6.7.1.1.54
Maximum ACM possible to use, given by the selected frame id
Status: current Access: read-only
OBJECT-TYPE    
  AcmTC  

selectedMinAcm 6.7.1.1.55
Selected minimum coding/modulation. If selectedMinACM = selectedMaxACM, then the modulation is fixed
Status: current Access: read-write
OBJECT-TYPE    
  AcmTC  

selectedMaxAcm 6.7.1.1.56
Selected maximum coding/modulation. If selectedMinACM = selectedMaxACM, then the modulation is fixed
Status: current Access: read-write
OBJECT-TYPE    
  AcmTC  

actualRxAcmTC 6.7.1.1.57
Actual rx modulation and coding
Status: current Access: read-only
OBJECT-TYPE    
  AcmTC  

actualTxAcmTC 6.7.1.1.58
Actual tx modulation and coding
Status: current Access: read-only
OBJECT-TYPE    
  AcmTC  

alignmentMode 6.7.1.1.59
Enable or disable the alignment mode
Status: current Access: read-write
OBJECT-TYPE    
  EnableStatusTC  

rfLoop 6.7.1.1.60
Enable or disable the rf loop
Status: current Access: read-write
OBJECT-TYPE    
  EnableStatusTC  

rltTable 6.7.3
A table of RLT Table entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RltEntry

rltEntry 6.7.3.1
An entry of RLT application.
Status: current Access: not-accessible
OBJECT-TYPE    
  RltEntry  

rltDistinguishedName 6.7.3.1.1
Unique id/name of the radio link termination, according to FDN (rack/slot/port/class)
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

neIpAddress 6.7.3.1.2
NE IP address
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

neIpv6Address 6.7.3.1.3
NE IP V6 address
Status: current Access: read-only
OBJECT-TYPE    
  InetAddressIPv6  

neName 6.7.3.1.4
NE Name
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

neType 6.7.3.1.5
NE Type
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), mle(2), xfMle(3), tn(4), cn(5), pt(6)  

id 6.7.3.1.6
User defined id of the radio link terminal
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

rltStatus 6.7.3.1.7
The status of the radio link terminal
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER down(1), up(2), na(3), unknown(4), degraded(5)  

mode 6.7.3.1.8
The status of the radio link terminal
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER mode1plus0(1), mode1plus1CSB(2), mode1plus1RLP(3), mode2plus0RLB(4), mode2plus1CSB(5), mode2plus1RLP(6), mode2plus2CSB(7), mode2plus2RLP(8), mode3plus0RLB(9), mode4plus0RLB(10), notAvailable11(11), notAvailable12(12), notAvailable13(13), notAvailable14(14), mode3plus1RLP(15), mode3plus2RLP(16), mode3plus3RLP(17), mode4plus1RLP(18), mode4plus2RLP(19), mode4plus3RLP(20), mode4plus4RLP(21), notAvailable22(22), notAvailable23(23), notAvailable24(24), notAvailable25(25), notAvailable26(26), notAvailable27(27), mode3plus1CSB(28), mode3plus2CSB(29), mode3plus3CSB(30), mode4plus1CSB(31), mode4plus2CSB(32), mode4plus3CSB(33), mode4plus4CSB(34), unknown(35)  

actualTxTotalCapacity 6.7.3.1.9
Actual aggregated total (packet + TDM) transmitter capacity for the radio link termination. Limited by licenses & configuration (=nearEndLimitedCapacity) and depending on actual modulation/coding used at the moment.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

limitedTotalCapacity 6.7.3.1.10
Maximum total capacity allowed by the current configuration and installed licenses. Aggregated from the constituent carrier termination values.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

protectionStatus 6.7.3.1.11
Status of a protected node.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unprotected(1), protected(2), unableToProtect(3), unknown(4)  

revertiveWaitToRestore 6.7.3.1.12
The time, in number of seconds, to wait before switching back to the preferred Tx.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

revertivePreferredTx 6.7.3.1.13
The preferred carrier termination transmitter.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ct11(1), ct12(2), ct21(3), ct22(4), notApplicable(5), unknown(6)  

protectionSwitchMode 6.7.3.1.14
.The mode in which the switching mechanism is configured
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), manual(2), autoAndRevertive(3), unknown(4), notApplicable(5)  

fadeNotificationTimer 6.7.3.1.15
Notification is sent if fading is longer than this timer, applicable for protection.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

expectedFarEndId 6.7.3.1.16
Expected id of far-end terminal
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

farEndIdCheck 6.7.3.1.17
Enabling of far end id check.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), unknown(3)  

cpriMode 6.7.3.1.18
Set the mode of the CPRI front-haul product.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER master(1), slave(2), notApplicable(3), unknown(4)  

cpriStatus 6.7.3.1.19
The status of the CPRI front-haul product.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER idle(1), waitingOnRtcSync(2), waitingOnCpri(3), waitingOnRxRequest(4), waitingOnTxRequest(5), inSync(6), unknown(7)  

manualSwitch 6.7.3.1.20
Manual switch of protected carrier termination transmitter.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ct11(1), ct12(2), ct21(3), ct22(4), notApplicable(5), unknown(6)  

mlhcOperStatus 6.7.3.1.21
Operative status of multi layer header compression.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2), unknown(3)  

mlhcAdminStatus 6.7.3.1.22
Administrative status of multi layer header compression.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2), unknown(3)  

mlhcMplsConfig 6.7.3.1.23
MLHC/MPLS configuration.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER controlWord(1), l2(2), l3(3), mplsOnly(4), unknown(5)  

plcOperStatus 6.7.3.1.24
Operative status of payload compression.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2), unknown(3)  

plcAdminStatus 6.7.3.1.25
Administrative status of payload compression.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2), unknown(3)  

ctG826ContinuousTable 6.7.4.1
A table of CT G826 Performance Continuous counters entries. The counters are reset by ctG826Reset
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CtG826ContinuousEntry

ctG826ContinuousEntry 6.7.4.1.1
An entry of CT G826 Performance Continuous counters.
Status: current Access: not-accessible
OBJECT-TYPE    
  CtG826ContinuousEntry  

ctG826TimeElapsed 6.7.4.1.1.1
Time elapsed in seconds since last PMReset
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ctBBE 6.7.4.1.1.2
Background Block Errors
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ctBBER 6.7.4.1.1.3
Background Block Errors Ratio
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

ctES 6.7.4.1.1.4
Error seconds
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ctESR 6.7.4.1.1.5
Error seconds Ratio
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

ctSES 6.7.4.1.1.6
Severely error seconds
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ctSESR 6.7.4.1.1.7
Severely error seconds Ratio
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

ctBB 6.7.4.1.1.8
Background blocks
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

ctUAS 6.7.4.1.1.9
Unavailable seconds
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ctG826Reset 6.7.4.1.1.10
Reset the continuous PM counters
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER other(1), noReset(2), reset(3)  

ctG826Current15mTable 6.7.4.2
A table of CT Performance G826 15 m current counters Table entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CtG826Current15mEntry

ctG826Current15mEntry 6.7.4.2.1
An entry of CT Performance G826 15 m current Table counters.
Status: current Access: not-accessible
OBJECT-TYPE    
  CtG826Current15mEntry  

ctG826Current15mTimeElapsed 6.7.4.2.1.1
Time elapsed in seconds since last PMReset
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ctCurrent15mBBE 6.7.4.2.1.2
Background Block Errors
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ctCurrent15mBBER 6.7.4.2.1.3
Background Block Errors Ratio
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

ctCurrent15mES 6.7.4.2.1.4
Error seconds
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ctCurrent15mESR 6.7.4.2.1.5
Error seconds Ratio
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

ctCurrent15mSES 6.7.4.2.1.6
Severely error seconds
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ctCurrent15mSESR 6.7.4.2.1.7
Severely error seconds Ratio
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

ctCurrent15mBB 6.7.4.2.1.8
Background blocks
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ctCurrent15mUAS 6.7.4.2.1.9
Unavailable seconds
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ctG826Current24hTable 6.7.4.3
A table of CT Performance G826 Current 24h counters entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CtG826Current24hEntry

ctG826Current24hEntry 6.7.4.3.1
An entry of CT Performance G826 Current 24 h counters.
Status: current Access: not-accessible
OBJECT-TYPE    
  CtG826Current24hEntry  

ctG826Current24hTimeElapsed 6.7.4.3.1.1
Time elapsed in seconds since last PMReset
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ctCurrent24hBBE 6.7.4.3.1.2
Background Block Errors
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ctCurrent24hBBER 6.7.4.3.1.3
Background Block Errors Ratio
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

ctCurrent24hES 6.7.4.3.1.4
Error seconds
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ctCurrent24hESR 6.7.4.3.1.5
Error seconds Ratio
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

ctCurrent24hSES 6.7.4.3.1.6
Severely error seconds
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ctCurrent24hSESR 6.7.4.3.1.7
Severely error seconds Ratio
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

ctCurrent24hBB 6.7.4.3.1.8
Background blocks
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ctCurrent24hUAS 6.7.4.3.1.9
Unavailable seconds
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ptRadioLinkCompliances 6.7.2.1
OBJECT IDENTIFIER    

ptRadioLinkGroups 6.7.2.2
OBJECT IDENTIFIER    

ptRadioLinkFullCompliance 6.7.2.1.1
The compliance statement for SNMP entities which implement everything.
Status: current Access: read-only
MODULE-COMPLIANCE    

ptRadioLinkCompleteGroup 6.7.2.2.1
A collection of all current objects in this MIB module.
Status: current Access: read-only
OBJECT-GROUP