AtmPvcTestOutputEntryLine |
|
SEQUENCE |
|
|
|
|
atmF5EndToEndBatchesLeft |
Counter32 |
|
LoopDiagResultEntry |
|
SEQUENCE |
|
|
|
|
loopDiagStatus |
INTEGER |
|
|
loopDiagAttainableBitRateNE |
Unsigned32 |
|
|
loopDiagLoopAttenuationNE |
Unsigned32 |
|
|
loopDiagSignalAttenuationNE |
Unsigned32 |
|
|
loopDiagSnrMarginNE |
Integer32 |
|
|
loopDiagActualTxPowerFarEndNE |
Integer32 |
|
|
loopDiagAttainableBitRateFE |
Unsigned32 |
|
|
loopDiagLoopAttenuationFE |
Unsigned32 |
|
|
loopDiagSignalAttenuationFE |
Unsigned32 |
|
|
loopDiagSnrMarginFE |
Integer32 |
|
|
loopDiagActualTxPowerFarEndFE |
Integer32 |
|
seltToneProfile |
1.3.6.1.4.1.193.72.300.20.1.1.1.8 |
Tone profile for different system configurations.
The unused values for this parameter are reserved for
comming standards or future proprietary techniques. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
ansit1413(0), etsi(1), g9921PotsNonOverlapped(2), g9921PotsOverlapped(3), g9921IsdnNonOverlapped(4), g9922PotsNonOverlapped(8), g9923AnnexA(13), g9923AnnexB(14), g9923AnnexJ(15), g9923ReAnnexAandL(16), g9923ReNarrowPsdAnnexAandL(17), g9925AnnexA(18), g9925AnnexB(19), g9925AnnexM(20), sadsl64(128) |
|
seltExtSplitterType |
1.3.6.1.4.1.193.72.300.20.1.1.1.14 |
External splitter filter type.
This parameter is used to inform the SELT software about
any installed external splitter filter. The SELT performance
is affected by this parameter.
The unused values for this parameter are reserved for
coming external splitter types or future proprietary options. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noneOrPOTS(0), edf110i(1), edf324Ncd90127R1a(2), edf324EtsiNcd90130R1a(3), kroneIsdn(4) |
|
seltTestBasicOutputEntry |
1.3.6.1.4.1.193.72.300.20.1.3.1 |
An entry contains the basic output parameters
for the SELT test for the subscriber line
identified by lineIndex. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SeltTestBasicOutputEntry |
|
|
seltTestAdvOutputEntry |
1.3.6.1.4.1.193.72.300.20.1.4.1 |
An entry contains the advanced output parameters
for the SELT test for the subscriber line
identified by lineIndex. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SeltTestAdvOutputEntry |
|
|
atmPvcTestOutputEntryLine |
1.3.6.1.4.1.193.72.300.20.1.12.4.1 |
An entry contains output parameters for
the ATM PVC test for the subscriber line
identified by lineIndex.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
AtmPvcTestOutputEntryLine |
|
|
atmPvcTestOutputEntryPvc |
1.3.6.1.4.1.193.72.300.20.1.12.6.1 |
An entry contains output parameters for the ATM PVC
test for the subscriber PVC identified by lineIndex,
atmPvcTestOutputTableVpiIndex, and atmPvcTestOutputTableVciIndex.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
AtmPvcTestOutputEntryPvc |
|
|
pppoeTestOutputEntry |
1.3.6.1.4.1.193.72.300.20.1.21.1 |
An entry contains **additional** output parameters for
the 'PPP-over-Ethernet' test for the subscriber line
identified by lineIndex. Zero or more entries may exists for each line. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
PppoeTestOutputEntry |
|
|
loopDiagResultEntry |
1.3.6.1.4.1.193.72.300.20.1.23.1 |
An entry contains the per line results of the
ADSL2 Loop Diagnostics for the subscriber line
identified by lineIndex. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
LoopDiagResultEntry |
|
|
loopDiagHlinNeEntry |
1.3.6.1.4.1.193.72.300.20.1.24.1 |
An entry contains the per subcarrier Hlin results
of the ADSL2 Loop Diagnostics for the subscriber
line identified by lineIndex.
NOTE Low designates the first 32 tones and High is
the upper 32 tones for that particular partId. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
LoopDiagHlinNeEntry |
|
|
loopDiagHlinFeEntry |
1.3.6.1.4.1.193.72.300.20.1.25.1 |
An entry contains the per subcarrier Hlin results
of the ADSL2 Loop Diagnostics for the subscriber
line identified by lineIndex.
NOTE: The partId specifies the section of the Hlin
table to return. The Hlin values returned correspond to
tones: partId * 64 to (partId * 64 + 63). PartId range is [0..7].
Low designates the first 32 tones and High is the upper 32
tones for that particular partId. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
LoopDiagHlinFeEntry |
|
|
loopDiagHlogEntry |
1.3.6.1.4.1.193.72.300.20.1.26.1 |
An entry contains the per subcarrier Hlog results
of the ADSL2 Loop Diagnostics for the subscriber
line identified by lineIndex.
NOTE: The partId specifies the section of the far-end (US)
Hlog table to return. The hlog values returned correspond to
tones partId * 128 to (partId * 128 + 127). PartId range
is [3..0]. Low designates the first 64 tones and High is
the upper 64 tones for that particular partId. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
LoopDiagHlogEntry |
|
|
loopDiagQlnEntry |
1.3.6.1.4.1.193.72.300.20.1.27.1 |
An entry contains the per subcarrier Qln results
of the ADSL2 Loop Diagnostics for the subscriber
line identified by lineIndex.
NOTE: The partId specifies the section of the far-end (US)
QLN table to return. The QLN values returned correspond
to tones partId * 256 to (partId * 256 + 255). PartId range
is [1..0]. Low designates the first 128 tones and High is
the upper 128 tones for that particular partId. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
LoopDiagQlnEntry |
|
|
loopDiagSnrEntry |
1.3.6.1.4.1.193.72.300.20.1.28.1 |
An entry contains the per subcarrier Snr results
of the ADSL2 Loop Diagnostics for the subscriber
line identified by lineIndex.
NOTE: The partId specifies the section of the
far-end (US) SNR table to return. The SNR values
returned correspond to tones partId * 256 to
(partId * 256 + 255). PartId range is [0..1].
Low designates the first 128 tones and High is
the upper 128 tones for that particular partId. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
LoopDiagSnrEntry |
|
|
peaTestIpDslamTrapsEntry |
1.3.6.1.4.1.193.72.300.20.2.0 |
OBJECT IDENTIFIER |
|
|
|